2
PUPILLOGRAPHY PUPILLOGRAPHY MS-39 has builn pupillography measurement soſtwa- re. The measurement of the pupil in scotopic (0.04 lux), mesopic (4 lux), photopic (50 lux) condions and in dynamic mode. Knowing the center and the diameter of the pupil, is essenal for many clini- cal procedures which seek to opmize vision quality. IOL CALCULATION MODULE IOL CALCULATION MODULE This module is based on Ray-Tracing techniques, regar- dless of the state of the cornea (untreated or previously treated for refracve purposes), provides the calculaon of the spherical and toric power of the intraocular lens. CRYSTALLINE BIOMETRY CRYSTALLINE BIOMETRY In order to more accurately determine the ELED, and consequently to refine the intra-ocular lens calculaon, MS-39 provides an acquision mode to measure the crystalline lens thickness, its distance from the cornea and its equator. INTRASTROMAL RINGS INTRASTROMAL RINGS On the basis of the pachymetry map and corneal al- metric data, MS-39 allows for intrastromal rings system planning, which maybe an opon for the correcon of refracve defects and some forms of keratoconus. GLAUCOMA SCREENING GLAUCOMA SCREENING For glaucoma specialists MS-39 enables the measu- re- ment of AOD, TISA and corneal pachymetry. These va- lues are useful in the diagnosis of the disease. ADVANCED ANALYSIS OF THE TEAR FILM ADVANCED ANALYSIS OF THE TEAR FILM Placido disk technology allows for the advanced analysis of the tear film, such as NIBUT (Non Invasive Break-up Time). Based on the Ocular Surface Disease Index que- sonnaire (OSDI), limbal and conjuncval hyperaemia, Meibomian glands analysis, tear meniscus analysis and tear osmolarity, calculated merging to- gether all paral scores, provides an owerall evaluaon of the clinical condion of the paent for a comprehesive diagnosis of the dry eye disease. FEATURES OF THE PHOENIX SOFTWARE FEATURES OF THE PHOENIX SOFTWARE MS-39 uses the Phoenix soſtware plaorm allowing pa- ent data to be saved for future review and analysis, sha- red by all CSO devices. KERATOCONOUS SCREENING KERATOCONOUS SCREENING Keratoconous screening provides the clinician with im- portant informaon about the panets cornea. Under- standing this can help prevent complicaons associated with ectasia before corneal surgery is undertaken. MS-39 AS-OCT Is the most advanced device for the analysis of the an- terior segment of the eye. MS-39 combines Placido disk corneal topography, with high resoluon OCT-ba- sed anterior segment tomography. The clarity of the cross-seconal images, with a 16 mm diameter, along with the many details of the cornea structure and layers revealed by the MS-39, will be appreciated by anterior segment specialists ᠀∁䨁鈁阀 爀甩㈱⸷o pachymetry, elevaon, curvature and dioptric power of both corneal sufaces. In addion to anterior segment cli- nical diagnoscs, MS-39 can be used in corneal surgery for refracve surgery planning. An IOL calculaon mo- dule is also available, based on Ray-Tracing techniques, Addional tools allow MS-39 to perform accurate pupil diameter measuremets and the advanced analysis of tear film. EPITHELIAL AND STROMAL MAP EPITHELIAL AND STROMAL MAP MS-39 includes the advanced measurement of the epi- thelial and stromal layer. The epithelial masking effect is known, so knowledge of its morphology is very useful assess abnormalies of the corneal surface. CORNEAL ABERROMETRY CORNEAL ABERROMETRY Aberrometric analysis offers a complete overview of the corneal aberraons. It is possible to select the contribu- on of the anterior, posterior or total cornea for diffe- rent pupil diameters. The OPD/WFE maps and the visual simulaons (PSF, MTF, image convoluon) can help the clinicain in understanding or explaining the paent’s vi- sual problems.

MS-39 CORNEAL ABERROMETRY - CSOitalia · 2020. 1. 10. · CORNEAL ABERROMETRY Aberrometric analysis o ffers a complete overview of the corneal aberrati ons. It is possible to select

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MS-39 CORNEAL ABERROMETRY - CSOitalia · 2020. 1. 10. · CORNEAL ABERROMETRY Aberrometric analysis o ffers a complete overview of the corneal aberrati ons. It is possible to select

PUPILLOGRAPHYPUPILLOGRAPHYMS-39 has builti n pupillography measurement soft wa-re. The measurement of the pupil in scotopic (0.04 lux), mesopic (4 lux), photopic (50 lux) conditi ons and in dynamic mode. Knowing the center and the diameter of the pupil, is essenti al for many clini-cal procedures which seek to opti mize vision quality.

IOL CALCULATION MODULEIOL CALCULATION MODULEThis module is based on Ray-Tracing techniques, regar-dless of the state of the cornea (untreated or previously treated for refracti ve purposes), provides the calculati on of the spherical and toric power of the intraocular lens.

CRYSTALLINE BIOMETRYCRYSTALLINE BIOMETRYIn order to more accurately determine the ELED, and consequently to refine the intra-ocular lens calculati on, MS-39 provides an acquisiti on mode to measure the crystalline lens thickness, its distance from the cornea and its equator.

INTRASTROMAL RINGS INTRASTROMAL RINGS On the basis of the pachymetry map and corneal alti -metric data, MS-39 allows for intrastromal rings system planning, which maybe an opti on for the correcti on of refracti ve defects and some forms of keratoconus.

GLAUCOMA SCREENINGGLAUCOMA SCREENINGFor glaucoma specialists MS-39 enables the measu- re-ment of AOD, TISA and corneal pachymetry. These va-lues are useful in the diagnosis of the disease.

ADVANCED ANALYSIS OF THE TEAR FILMADVANCED ANALYSIS OF THE TEAR FILMPlacido disk technology allows for the advanced analysis of the tear film, such as NIBUT (Non Invasive Break-up Time). Based on the Ocular Surface Disease Index que-sti onnaire (OSDI), limbal and conjuncti val hyperaemia, Meibomian glands analysis, tear meniscus

analysis and tear osmolarity, calculated merging to-gether all parti al scores, provides an owerall evaluati on of the clinical conditi on of the pati ent for a comprehesive diagnosis of the dry eye disease.

FEATURES OF THE PHOENIX SOFTWAREFEATURES OF THE PHOENIX SOFTWAREMS-39 uses the Phoenix soft ware platf orm allowing pa-ti ent data to be saved for future review and analysis, sha-red by all CSO devices.

KERATOCONOUS SCREENINGKERATOCONOUS SCREENINGKeratoconous screening provides the clinician with im-portant informati on about the pati nets cornea. Under-standing this can help prevent complicati ons associated with ectasia before corneal surgery is undertaken.

MS-39AS-OCT

Is the most advanced device for the analysis of the an-terior segment of the eye. MS-39 combines Placido disk corneal topography, with high resoluti on OCT-ba-sed anterior segment tomography. The clarity of the cross-secti onal images, with a 16 mm diameter, along with the many details of the cornea structure and layers revealed by the MS-39, will be appreciated by anterior segment specialists. MS-39 provides informati on on

pachymetry, elevati on, curvature and dioptric power of both corneal sufaces. In additi on to anterior segment cli-nical diagnosti cs, MS-39 can be used in corneal surgery for refracti ve surgery planning. An IOL calculati on mo-dule is also available, based on Ray-Tracing techniques, Additi onal tools allow MS-39 to perform accurate pupil diameter measuremets and the advanced analysis of tear fi lm.

EPITHELIAL AND STROMAL MAPEPITHELIAL AND STROMAL MAPMS-39 includes the advanced measurement of the epi-thelial and stromal layer. The epithelial masking eff ect is known, so knowledge of its morphology is very useful assess abnormaliti es of the corneal surface.

CORNEAL ABERROMETRYCORNEAL ABERROMETRYAberrometric analysis off ers a complete overview of the corneal aberrati ons. It is possible to select the contribu-ti on of the anterior, posterior or total cornea for diff e-rent pupil diameters. The OPD/WFE maps and the visual simulati ons (PSF, MTF, image convoluti on) can help the clinicain in understanding or explaining the pati ent’s vi-sual problems.

Page 2: MS-39 CORNEAL ABERROMETRY - CSOitalia · 2020. 1. 10. · CORNEAL ABERROMETRY Aberrometric analysis o ffers a complete overview of the corneal aberrati ons. It is possible to select

0051

TECHNICAL DATA

Data transfer USB 3.0

Power supply external power source 24 VDCIn: 100-240Vac - 50/60Hz - 2A - Out: 24Vdc - 100W

Power cable IEC C14 plug

Dimensions (HxWxD) 505 x 315 x 251mm

Weight 10.4Kg

Chin rest movement 70mm ± 1mm

Minimum height of the chin cup from table 23cm

Base movement (xyz) 105 x 110 x 30mm

Working distance: 74mm

LIGHT SOURCES

Placido disk illuminati on Led @635nm

OCT source SLed @845nm

Pupillographic illuminati on Led @950nm

TOPOGRAPHY

Placido disk rings 22

Measured points 31232 (anterior surface) 25600 (posterior surface)

Topographic covering 10mm

Dioptric measurement range from 1D to 100DMeasurement accuracy Class A according to UNI EN ISO 19980-2012SECTION

Image fi eld 16mm x 8mm

Axial resoluti on 3.6 µm (in ti ssue)

Transversal resoluti on 35 µm (in air)

Image(s) resoluti onKeratoscopy (640x480) + 25 radial scans on a 16mm transversal fi eld (1024 A-scan) - Secti on: on 16mm (1600 A-scan) on 8mm (800 A-scan)

Operati ng system Windows 10 (64 bit)

*The specifi cati ons and the images are not contractually binding and can be modifi ed without noti ce. Windows® is a Microsoft Corporati on trade mark.

CO125 | Rev. 02 del 15/03/2019

YOUR PROFESSIONAL PARTNER SINCE 1967

0051

Via degli Stagnacci 12/E50018 - Scandicci - FI - Italytel +39 055 72219 | fax +39 055 7215557email. [email protected] | web. www.csoitalia.it

MS-39AS-OCT MS-39

AS-OCT

EN