at an afordable price.
Samsung is thrilled to introduce the new Inverter Light.
intake, the Samsung Inverter Light maximises energy eiciency
Contact your local distributor for more information.
Gauteng & Central region W. & N. Cape E.Cape Kwa-Zulu NatalJHB & Central: (011) 704-6320 Pretoria: (012) 643-0445 W & N Cape: (021) 556-8292 Bloemfontein: 083 381 0074
Kwa-Zulu Natal: (031) 579-1895 Port Elizabeth: (041) 484-6413 George: 082 380 0708
D i s t r i b u t e d & s u p p o r t e d n a t i o n w i d e b y Fo u r w a y s A i r c o n d i t i o n i n g :
Samsung Inverter High Static Duct Airconditioner
Samsung quality and energy-eicient Inverter
technology ensure economical, reliable
airconditioning of large areas
• Top-quality energy-eicientInverter Ducted heating / cooling
• High COP’s
• 200m piping length to outdoorunit / 110m elevation
• Environmentally-friendly R410A gas
PDF Compressor Pro
JHB & Central: (011) 704-6320 Pretoria: (012) 643-0445 W & N Cape: (021) 556-8292 Bloemfontein: 083 381 0074
Kwa-Zulu Natal: (031) 579-1895 Port Elizabeth: (041) 484-6413 George: 082 380 0708
Inverter High Static Duct Speciications
Distributed & supported nationwide by Fourways Airconditioning:
er ply
Capacity
(Nominal)
Power Input
(Nominal)
Current Input
(Nominal)
Motor
Air Flow Rate
External Pressure
Liquid Pipe
Gas Pipe
Net Weight
Shipping Weight
Net Dimensions (WxHxD)
Cooling *2)
Heating *3)
Cooling *2)
Heating *3)
Cooling *2)
Heating *3)
Output
H/M/L (UL)
Min / Std / Max
-
kW
Btu/h
kW
Btu/h
W
W
A
A
W
I/s
Pa
Ø, mm
Ø, inch
Ø, mm
Ø, inch
kg
kg
mm
Power Supply
Performance
Power
COP
Fan
Piping Connections
External Dimensions
Operating Temp. Range
Capacity
(Nominal)
Power Input
(Nominal)
Current Input
(Nominal)
MFA
Nominal Cooling 1)
Nominal Heating 2)
ESEER
External Static Pressure
Liquid Pipe
Gas Pipe
Net Weight
Shipping Weight
Net Dimensions (WxHxD)
Cooling
Heating
Cooling
Heating
Cooling 1)
Heating 2)
Cooling 1)
Heating 2)
Max.
Ø, #, V, Hz
kW
Btu/h
kW
Btu/h
kW
kW
A
A
A
-
-
-
Pa
Ø, mm
Ø, inch
Ø, mm
Ø, inch
kg
kg
mm
ºC
ºC
3,4, 380 ˜ 415, 50
22.4
76,400
25.20
86,000
5.00
5.10
8.00
8.20
30
4.48
4.94
7.85
78.45
9.52
3/8
19.05
3/4
190.00
206.00
880 x 1,695 x 765
-5.0 ˜ 48.0
-20.0 ˜ 24.0
3,4, 380 ˜ 415, 50
28.0
95,500
31.50
107,500
6.80
6.70
10.90
10.70
40
4.12
4.70
7.25
78.45
9.52
3/8
22.22
7/8
190.00
206.00
880 x 1,695 x 765
-5.0 ˜ 48.0
-5.0 ˜ 24.0
OUTDOOR UNIT
MODEL INDOOR UNIT
Power Supply
Mode *1)
Performance
Power
Fan
Piping Connections
Dimensions
AM220FNHDEH
HP
22.4
76,400
25.0
85,300
530
530
3.8
3.8
400
966.67/866.67/783.33
49.03/147.10/245.17
9.52
3/8
19.05
3/4
89.00
99.00
1240 x 470 x 1040
AM280FNHDEH
HP
28.0
95,500
31.5
107,500
790
790
5.9
5.9
400
1.200.00/1.083.33/966.67
49.03/147.10/274.59
9.52
3/8
22.23
7/8
89.00
99.00
1240 x 470 x 1040
Ø, #, V, Hz 1, 2, 220 ˜ 240, 50 1, 2, 220 ˜ 240, 50
* Specifications may be subject to change without prior notice for products improvement.*1) Mode
-HP: Heat Pump, HR: Heat Recovery*2) Nominal cooling capacities are based on:
- Indoor temperature: 27ºC DB, 19ºC WB / Outdoor temperature: 35ºC DB, 24ºC WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m*3) Nominal heating capacities are based on:
- Indoor temperature: 20ºC DB, 15ºC WB / Outdoor temperature: 7ºC DB, 6ºC WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m*4) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions.