12
MS10-0200-1 Rev d (10-2010) DCN0530

MS10-0200-1 Rev d (10-2010) DCN0530 - ABB Group · Maximum voltage and current ratings ... float of the switch is allowed to move freely up and down with ... MS10-0200-1 Rev d (10-2010)

Embed Size (px)

Citation preview

MS10-0200-1 Rev d (10-2010) DCN0530

MS10-0200-1 Rev d (10-2010) DCN0530 2

TABLE OF CONTENTS 1.0 INTRODUCTION ................................................................................................................................................ 3

2.0 SPCIFICATIONS ................................................................................................................................................ 6

3.0 ORDERING INFORMATION .............................................................................................................................. 7

4.0 MAINTENANCE. ................................................................................................................................................ 8

5.0 APPENDIX ......................................................................................................................................................... 8

6.0 WARRANTY ....................................................................................................................................................... 12

MS10-0200-1 Rev d (10-2010) DCN0530 3

1.0 INTRODUCTION Description: The MS10 is a magnetically isolated single pole double throw point level switch. When the MS10 is inserted into a process vessel or external chamber it can sense high or low levels within the vessel. The unique magnetic isolation action eliminates the need for such things as seals, diaphragms, springs, or torque tubes because there is no physical contact with the process. he MS10 typically requires no preventive maintenance since it is totally sealed. The switch is not protected against radiation, electro-magnetic devices, parmeant magnets or excessive mechanical vibration.

Operation: The MS10 will provide either a normally open or normally closed dry contact, which may be used to activate external devices such as alarms or solenoids. The capacity of the switch allows for control of a wide range of de-vices. Maximum voltage and current ratings are listed in the specification section of this manual. Variations in proc-ess fluid specific gravity (0.4 minimum clean fluid SG) have minimal effect because of the small size of the integral float. The float tracks the liquid level and provides for an electrical contact output (SPDT). These contacts are suitable for use with alarms and/or to activate a pump motor starter relay.

Installation: The MS10 is mounted to the process vessel via the integral 1-1/2” MNPT fitting. Suitable reducers and/or adapters may be used provided they do not interfere with the full stroke of the float. The MS10 should be tightened such that the electrical connection is at its uppermost position. The following procedures outline the steps necessary to install the switch. WARNING! MAKE SURE CIRCUIT IS DE-ENERGIZED WHILE INSTALLING THE SWITCH.

1. Inspect the switch for any signs of damage incurred during shipment. Mount the switch in a process connection at the point in which you want the switch to trip. Use of a suitable lubricant/sealing compound is recommended. During final tightening, align the MS10 electrical connection to the topmost position as shown (Figure 1). A 2" wrench is needed for tightening. The electrical contacts may be installed either before or after installing the switch housing (Figure 2). Be sure to push the retainer assembly firmly into the switch housing during installa-tion. The retainer assembly may be removed to facilitate removal of the switch assembly, if necessary. Note: The MS10 will also function when the electrical connection is aligned to the lowest position (bottom), however the electrical contacts will function opposite of the diagram (Figure 3).

2. Connect the field wires to the wiring harness of the MS10 according to the application. Reference Figure 3 for proper operation of contacts. Be sure to adequately insulate all electrical connections.

3. The liquid level inside the vessel should be cycled above and below the switch and operation of the contacts should be verified.

4. The float of the switch shall always be mounted in a straight horizontal position, arrow pointing up, so that the float of the switch is allowed to move freely up and down with the process. Obstruction of the float will cause in-accurate and erroneous readings to be relayed by the switch that could cause a hazardous condition to develop.

5. Competent personnel should only perform installation and maintenance procedures on process control equip-ment and these switches.

6. Placement of switches should be only where the effects of a hazardous atmosphere will not effect the material integrity of the apparatus. It is a requirement the installation personnel to assure the hazardous atmosphere or the surrounding atmosphere will not compromise the long-term integrity (strength, conductivity, corrosion) of the switch material.

MS10-0200-1 Rev d (10-2010) DCN0530 4

Figure 1 – MS10 Alignment

Vessel Wall

Align to topmost position

Switch Housing

7. Warranty/Repair/Replacement:

8. For warranty, repair, or replacement of transmitter call the K-TEK service department at 225-673-6100. The ser-vice department is located in Prairieville, Louisiana 70769, USA.

9. The material construction of these units offers no particular protection against radiation, electro-magnetic or mechanical hazards. The construction of units is not designed to protect against other hazardous not defined in above sentence.

10. Strong magnetic fields should not be placed around the switch (reed switch is magnetically coupled) in order to prevent inaccurate and erroneous readings, which could cause a hazardous condition to develop.

11. Avoid aggressive substances that could drip, spill, pour, or fall on the switch and cause premature failure of the material or wiring resulting in inaccurate and erroneous readings which could lead to a hazardous condition.

Note: A.) Field wiring connected to the MS10 switch must comply with applicable sections of the National Electrical Code. Do not install/use in environments that would allow the metal of the switch to react with the contents (liquid or va-por) which could cause corrosion and metal fatigue.

C(WHITE)

C(WHITE)

2(BLACK)

1(RED)

2(BLACK)

LEVEL BELOW SWITCH

LEVEL ABOVE SWITCH

Figure 3 – Operation of Electrical Contacts

Figure 2 – Installation of MS10 Electrical Contacts

Switch Assembly Retainer Assembly

Switch Housing

1(RED)

MS10-0200-1 Rev d (10-2010) DCN0530 5

2.0 SPECIFICATIONS

Switch Type: Magnetically actuated, hermetically sealed, bi-stable switch. Single pole double throw (Form C).

Switch Action: Break before make

Contact Material: Rhodium alloy

Max. Dead Band: Approx. ± 0.50" of float travel

Contact Ratings: AC Rating: 250 VAC, 1Amp, 250 VA resistive

(Non IS Ratings) DC Rating: 250 VAC, 1Amp, 250 W resistive

If higher contact ratings are required see:

IR10/10 Amp Interposing Relay (IR10-0202-1)

PP10/10 Amp Pump-Pak Controller (PP10-0202-1)

Process Temperature: -100 to 450oF / -73 to 232oC

Contact factory regarding use in colder applications

Contact Temperature: -40 to 302°F / -40 to 150°C

Max. Pressure: 1500 psig / 103 bar (Standard)

5000 psig / 345 bar with HP1 option

Customer Connection: 1-1/2” MNPT Process, ½” FNPT conduit and AWG 20 wiring harness

(18inch). MS10 housing is 2” Hex for tightening into process connection

Insertion Length: 3-5/8” (Standard)” Otionnal 5” or 6-1/2” Insertion Length

Consult Factory for Special Applications

Specific Gravity: 0.4 Minimum (Clean Fluid)

Approvals:

Factory Mutual Approved XP CL I, Div 1, GP ABCD

CL I, Zn 1 AEx d IIC

IS CL I, Div 1, GP ABCD CL I, Zn 0 AEx ia IIC T6

DIP CL II, III, Div 1, GP EFG

CSA Approved XP CL I, Div 1, GP ABCD

CL I, Zn 1 Ex d IIC

IS CL I, Div 1, GP ABCD CL I, Zn 0 Ex ia IIC T6

DIP CL II, III, Div 1, GP EFG

ATEX Approved: II 1G EEx ia IIC T6 (-40C<Tamb<80C)

MS10-0200-1 Rev d (10-2010) DCN0530 6

3.0 ORDERING INFORMATION:

MS10/a/b/c/d/e/f/g

/a Mounting Orientation

/H Horizontal (Standard)

/b

Process Connection

/15 1-1/2” MNPT (Standard)

/20 2” MNPT

/WPxx Welded Flange

/T2 2” NPT 3000# Modified Tee

Includes 1-1/2” X 2“ Reducer Bushing

/S2 2” Socket Weld 3000# Modified Tee

Includes 1-1/2” X 2“ Reducer Bushing

/c

Flange or Mounting Adapter Material

/S6 316/L Stainless Steel

/S4 304/L Stainless Steel

/CST Carbon Steel

/d Nametag with Customer Specified Options

/NT 316 Stainless Steel Nametag with Customer Specified Options

/e

Insertion Length

/EXT1 4 in. / 101 mm Insertion Length (Standard)

/EXT2 5 in. / 127 mm Insertion Length

/EXT3 6-1/2 in. / 165 mm Insertion Length

/EXTn Custom Insertion Length

/f

Other Options

/HP 5000# psig / 345 bar

1. Available with /EXT1 only

2. Flanged Process Connection Required

3. Contact Factory Regarding Materials of Construction

/g

Approvals

/FM Factory Mutual Flameproof and Intrinsically Safe (Standard)

/CSX CSA Flameproof

/CSI CSA Intrinsically Safe

/CEI ATEX Intrinsically Safe (Not for Flameproof Installations)

MS10-0200-1 Rev d (10-2010) DCN0530 7

4.0 MAINTENANCE

The MS10 does not require any routine maintenance in normal day to day operation. WARNING! If there is a need to take the switch out of service or disconnect it for any reason, then make sure the circuit is de-energized, or insure that the area is known to be non-hazardous! Handling & Storage Requirements: There are no special handling and storage requirements associated with this device.

5.0 APPENDIX Explosion Proof Installation: (Non-Intrinsically Safe Installation for ATEX IS Installations see page 7) Many of K-TEK’s switch products (MS10, MS30, MS50) are based on magnetically operated reed switches. Since reed switches have the inherent characteristic of very closely spaced switch contacts, it is extremely important to protect these contacts from high voltage transients caused by inductive loads. When an inductive load is de-energized, the collapsing magnetic field induces a high voltage of opposite polarity into itself and thus the switch. Two basic methods exist to clamp this voltage and thus protect the switch contacts.

D.C. Applications For D.C. applications, a diode is placed in parallel with the inductive load (note the polarity of the diode and power supply). A 1N4001 general purpose diode is normally sufficient to clamp the induced voltage of the inductive load to a safe level.

REED SWITCH INDUCTIVE LOAD

DIODE

+ V -

D.C. Contact Protection

MS10-0200-1 Rev d (10-2010) DCN0530 8

A.C. Applications For A.C. applications, a Metal Oxide Varistor (MOV transient surge suppressor) is placed either in paral-lel with the switch or the inductive load. The MOV changes from a high impedance to a very low imped-ance when the voltage across the MOV exceeds its rated voltage (the MOV rating must correspond with the power supply voltage). For 120 VAC control sys-tems a typical MOV would be the GE (General Elec-tric Co.) part number V130LA10A. In either case shown, the result is the limiting of the switch voltage to approximately 130 volts.

REED SWITCH INDUCTIVE LOAD

MOV

REED SWITCH INDUCTIVE LOAD

MOV

OR

A.C. Contact Protection

Explosion Proof Applications The switch has been rated for explosion proof applications by Factory Mutual (FM) and the Canadian Standards As-sociation (CSA) only. For typical/specific explosion proof installation see NEC 500 or NEC 505, or IEC directives. The MS10 is not approved for flameproof (European) application at this time. Intrinsically Safe Applications This switch is ATEX approved in IS installations (EEx ia) Zone 0 in Europe by DEMKO, in the U.S. by FM and in Canada by CSA This switch can be used in areas/processes that do not have explosive environments. For a typi-cally IS installation application please see the example below. If only two wires are used, then the 3

rd wire must be electrically and physically insulated from the circuit. For use with

three (3) wires, that is, use of the Normally Closed (NC) and Normally Opened (NO) contacts, a second IS barrier is required.

MS10-0200-1 Rev d (10-2010) DCN0530 9

CRITICAL / SCHEDULE DOCUMENT

NO MODIFICATION PERMITTED WITHOUT APPROVAL

FROM AGENCY / NOTOFIED BODY

This IS installation hook-up is good for: Europe under ATEX approval U.S. under FM approval Canada under CSA approval ATEX Note: “High Pressure” (/H) option switch uses a titanium float. Caution: Foreign objects (metals made of other material) sticking the titanium float could cause a spark. Use cau-tion to prevent such conditions for arising.

MS10-0200-1 Rev d (10-2010) DCN0530 10

Replacement of switch (SPDT) on the MS10: * The MS10 switch must be replaced with K-Tek’s part number MS10-4 reed switch because the switch is potted for dimensions to fit inside of the SS tubing. Disconnect the power that runs through/to the switch (Assure that removing the power will not effect your process or process control) Lock-out and Tag-out the power so that power can not be applied to the switch until after the switch has been com-pletely repaired/replaced It is not necessary to remove the MS10 from the process to replace the reed switch Remove retaining ring with small screwdriver Remove the rubber grommet Pull out the magnetic reed switch by the wires Put in the replacement reed switch Replace grommet & retaining ring Disconnect the wires (2 or 3 wires) on old switch, noting the connections and colors, and re-connect the wires to the new switch according to hook-up of the old wiring. Ensure that the applied wattage & current do not exceed the power & current rating of the switch Remove the Lock-out / Tag-out device from the applied power Before applying power assure that this will not effect your process or process control Apply power and check the switch to assure that it is functioning properly Note: For the switch to operate (make and break contact) in the process, the fluid/process must be lower and raised above the level of the float.

MS10-0200-1 Rev d (10-2010) DCN0530 11

5 YEAR WARRANTY FOR:

KM26 Magnetic Liquid Level Gauges; MagWave Dual Chamber System; LS Series Mechanical Level Switches (LS500, LS550,

LS600, LS700, LS800 & LS900) (does NOT include switching mechanisms, ie. MS30, MS40, MS41, PS35 & PS45); EC External

Chambers, STW Stilling Wells and ST95 Seal Pots.

3 YEAR WARRANTY FOR:

KCAP300 & KCAP400 capacitance switches. BETA Pressure and Temperature Switches have a limited factory guarantee,

excluding wetted parts & consumables.

2 YEAR WARRANTY FOR:

AT100, AT100S and AT200 series transmitters; RS80 and RS85 liquid vibrating fork switches; RLT100 and RLT200 reed switch

level transmitters; TX, TS, TQ, IX and IM thermal dispersion switches; IR10 and PP10 External Relays; MT2000, MT5000,

MT5100 and MT5200 radar level transmitters; RI100 Repeat Indicators; KP paddle switches; A02, A75 & A77 RF capacitance

level switches and A38 RF capacitance level transmitters; Buoyancy Level Switches (MS50, MS10, MS8D & MS8F); Magnetic

Level Switches (MS30, MS40, MS41, PS35 & PS45).

1 YEAR WARRANTY FOR:

KM50 gauging device; AT500 and AT600 series transmitters; LaserMeter and SureShot series laser transmitters; LPM200 digital

indicator; DPM100 digital indicators; APM100 analog indicators; KVIEW series digital indicators and controllers; GRANUPOINT

and SLUDGEPOINT vibrating fork switches, SOLITRAK Electro-Mechanical Continuous Measuring Devices, KSONIK ultrasonic

level switches, transmitters & transducers, ChuteMaster Microwave Transmitter / Receiver and TiltMaster Switches.

SPECIAL WARRANTY CONSIDERATIONS:

K-TEK does not honor OEM warranties for items not manufactured by K-TEK (i.e. Palm Pilots). These claims should be handled

directly with the OEM.

K-TEK will repair or replace, at K-TEK’s election, defective items which are returned to K-TEK by the original purchaser within the

period specified above from the shipment date of the item and which is found, upon examination by K-TEK, to its satisfaction, to

contain defects in materials or workmanship which arose only under normal use and service and which were not the result of

either alterations, misuse, abuse, improper or inadequate adjustments, applications or servicing of the product. K-TEK’s warranty

does not cover the repair or replacement of units that fail from the effects of excessive vibration unless the units are originally

designed for vibration application. In addition, K-TEK’s warranty does not include on-site repair or services. Field service

rates can be supplied on request.

If a product is believed to be defective, the original purchaser shall notify K-TEK and request a Returned Material Authorization

before returning the material to K-TEK, with transportation prepaid by the purchaser. (To expedite all returns/repairs from

outside of the United States, consult K-TEK’s customer service team ([email protected]) to determine an optimal solution for

shipping method and turnaround time.) The product, with repaired or replaced parts, shall be returned to the purchaser at any

point in the world with transportation prepaid by K-TEK for best-way transportation only. K-TEK is not responsible for expedited

shipping charges. If the product is shipped to K-TEK freight collect, then it will be returned to the customer freight collect.

If inspection by K-TEK does not disclose any defects in material or workmanship, K-TEK’s normal charges for repair and

shipment shall apply (minimum 250.00 USD).

The materials of construction for all K-TEK products are clearly specified and it is the responsibility of the purchaser to determine

the compatibility of the materials for the application.

6.0 WARRANTY

MS10-0200-1 Rev d (10-2010) DCN0530 12