420 418 419 417 416 415 413 412 409 408 407 405 414 411 431 423A 422 425 426 427 424 421A 421 428 429 432 434 435 436 437 451 450 449 448 447 446 445 444 443 442 441 440 430 458 454 455 456 457 446A 457A 402 401 404 452 453 459 460 438 433 406 410 403A 403 431A 425A 423 DN DN UP DN DN DN DN DN DN UP UP PROJECT LOCATION NOT IN SCOPE NOT IN SCOPE STAGING AREA ACCESS TO PROJECT DO NOT USE THIS STAIR NOT IN SCOPE PROJECT LOCATION MONTANA STATE UNIVERSITY REID HALL BOZEMAN, MT 59717 NORTH NTS W LINCOLN ST S 11TH AVE W COLLEGE ST W COLLEGE ST W GRANT ST W GARFIELD ST 12TH AVE S 8TH AVE S 7TH AVE S 6TH AVE W CLEVELAND ST BOBCAT CIR STAGING AREA SUMMARY OF WORK: CLASSROOM INTERIOR UPGRADES MONTANA STATE UNIVERSITY ADDRESS: REID HALL, ROOM 401 AND 402, BOZEMAN, MT 59717 DESCRIPTION: THE EXISTING 2 CLASSROOMS ARE TO BE COMBINED INTO A LARGER UPDATED CLASSROOM. THIS WILL INCLUDE NEW CEILINGS, SOFFITS, WALL FINISHES, LIGHTING, FLOORING AND FURNITURE. THE EXISTING STRUCTURE WILL MAINTAIN ITS 1 HR RATING. REV. DESCRIPTION DATE REVIEWED BY: DRAWN BY: SHEET DATE SHEET TITLE MONTANA STATE UNIVERSITY MSU-CPDC MONTANA STATE UNIVERSITY BOZEMAN, MONTANA PHONE: 406.994.5413 FAX: 406.994.5665 428 N. Last Chance Gulch Helena, Montana 59601 406.449.2013 phone www.mosaicarch.com a r c h i t e c t u r e - p l a n n i n g - d e s i g n MSU CLASSROOM RENOVATIONS 2019 REID HALL 401,402 - 100% CD SET MOSAIC MOSAIC COVER SHEET - REID 401,402 A001 01/23/2019 REID HALL ROOMS 401 & 402 PPA#18-2170 ARCHITECTURAL SHEETS A001 COVER SHEET - REID 401,402 A003 DEMO PLANS - REID 401, 402 A008 GENERAL & CODE ANALYSIS - REID 401,402 A100 FLOOR PLANS & RCP - REID 401, 402 A200 INTERIOR ELEVATIONS - REID 401, 402 A300 SECTIONS - REID 401, 402 A400 DETAILS - REID 401,402 A401 DETAILS, ALT & BASEBID - REID 401,402 A402 DETAILS, CLG - REID 401,402 A500 SCHEDULES, FINISH PLAN - REID 401,402 A700 FURNITURE PLANS - REID 401, 402 MSU CLASSROOM RENOVATIONS 2019 REID HALL ROOMS 401 & 402 RENOVATION PPA#18 - 2170 ADDRESS: REID HALL MONTANA STATE UNIVERSITY BOZEMAN, MT 59717 PROJECT DIRECTORY MECHANICAL/ELECTRICAL/ PLUMBING ENGINEERING: 2880 TECHNOLOGY BLVD. WEST P.O. BOX 1113 BOZEMAN, MT 59771 - 1113 (406) 587 - 0721 CONTACT: Matt Carr, PE, LEED AP mcarr@m - m.net ARCHITECT: MOSAIC ARCHITECTURE, P.C. 428 North Last Chance Gulch Helena, MT 59601 Ph. 406 - 449 - 2013 CONTACT(S) : Jeff Downhour, [email protected] Kalina Vander Poel, [email protected] SHEET INDEX VICINITY MAP REID HALL LEVEL 4 - KEY MAP CLASSROOM RENDERING MEP SHEETS E001 SYMBOLS & ABBREVIATIONS E101 POWER & SIGNAL PLANS - REID 401/402 E102 LIGHTING PLANS - REID 401/402 M101 MECHANICAL PLAN - REID 401/402 REID HALL LEVEL 4 - HAZARDOUS MATERIALS FLOOR PLAN (NTS)

MSU CLASSROOM RENOVATIONS 2019 REID HALL ROOMS 401 & … Reid Hall Rms 401-402... · bobcat cir staging area summary of work: classroom interior upgrades montana state university

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

420 418

419

417

416

415 413412 409 408 407 405

414 411

431

423A

422

425

426 427424

421A

421

428 429 432 434 435 436 437

451450

449

448

447

446

445

444

443

442

441

440

430

458

454 455

456457

446A 457A

402

401

404

452

453

459

460

438

433 406

410

403A403

431A

425A

423

DNDN

UP DN

DN

DNDN

DN

DN

UP

UP

PROJECT LOCATION

NOT IN SCOPE

NOT IN SCOPE

STAGING AREA ACCESS TO PROJECT

DO NOT USE THIS STAIR

NOT IN SCOPE

PROJECT LOCATIONMONTANA STATE UNIVERSITYREID HALLBOZEMAN, MT 59717

NORTH

NTS

W LINCOLN ST

S 11

TH A

VE

W COLLEGE STW COLLEGE ST

W GRANT ST

W GARFIELD ST

12TH AVE

S 8T

H AV

E

S 7T

H AV

E

S 6T

H AV

E

W CLEVELAND ST

BOBC

AT C

IRSTAGING AREA

SUMMARY OF WORK:CLASSROOM INTERIOR UPGRADESMONTANA STATE UNIVERSITYADDRESS: REID HALL, ROOM 401 AND 402, BOZEMAN, MT 59717

DESCRIPTION: THE EXISTING 2 CLASSROOMS ARE TO BE COMBINED INTO A LARGER UPDATED CLASSROOM. THIS WILL INCLUDE NEW CEILINGS, SOFFITS, WALL FINISHES, LIGHTING, FLOORING AND FURNITURE. THE EXISTING STRUCTURE WILL MAINTAIN ITS 1 HR RATING.

REV. DESCRIPTION DATE

REVIEWED BY:DRAWN BY:

SHEET

DATE

SHEET TITLE

MO

NT

AN

AST

AT

E U

NIV

ER

SIT

Y

MSU-CPDCMONTANA STATE UNIVERSITY

BOZEMAN, MONTANAPHONE: 406.994.5413

FAX: 406.994.5665

428

N. L

ast C

hanc

e G

ulch

Hel

ena,

Mon

tana

5960

140

6.44

9.20

13ph

one

ww

w.m

osai

carc

h.co

m

a r c

h i

t e c

t u

r e -

p l a

n n

i n

g -

d e

s i g

n

MSU

CL

ASS

RO

OM

RE

NO

VA

TIO

NS

2019

REI

D H

ALL

40

1,4

02

-1

00

% C

D S

ET

MOSAICMOSAIC

COVER SHEET - REID401,402

A00101/23/2019

RE

ID H

AL

L R

OO

MS

401

& 4

02

PPA#18-2170

ARCHITECTURAL SHEETS

A001 COVER SHEET - REID 401,402A003 DEMO PLANS - REID 401, 402A008 GENERAL & CODE ANALYSIS - REID 401,402A100 FLOOR PLANS & RCP - REID 401, 402A200 INTERIOR ELEVATIONS - REID 401, 402A300 SECTIONS - REID 401, 402A400 DETAILS - REID 401,402A401 DETAILS, ALT & BASEBID - REID 401,402A402 DETAILS, CLG - REID 401,402A500 SCHEDULES, FINISH PLAN - REID 401,402A700 FURNITURE PLANS - REID 401, 402

MSU CLASSROOM RENOVATIONS 2019REID HALL ROOMS 401 & 402 RENOVATION

PPA#18-2170ADDRESS: REID HALL

MONTANA STATE UNIVERSITYBOZEMAN, MT 59717

PROJECT DIRECTORY

MECHANICAL/ELECTRICAL/PLUMBING ENGINEERING:

2880 TECHNOLOGY BLVD. WESTP.O. BOX 1113BOZEMAN, MT 59771-1113(406) 587-0721

CONTACT: Matt Carr, PE, LEED [email protected]

ARCHITECT:

MOSAIC ARCHITECTURE, P.C.428 North Last Chance GulchHelena, MT 59601Ph. 406-449-2013

CONTACT(S) : Jeff Downhour, [email protected] Vander Poel, [email protected] INDEX

VICINITY MAPREID HALL LEVEL 4 - KEY MAP

CLASSROOM RENDERING

MEP SHEETS

E001 SYMBOLS & ABBREVIATIONSE101 POWER & SIGNAL PLANS - REID 401/402E102 LIGHTING PLANS - REID 401/402M101 MECHANICAL PLAN - REID 401/402

REID HALL LEVEL 4 - HAZARDOUS MATERIALS FLOOR PLAN (NTS)

1.2. 2.

3

4.

5.

6.

6.

6.

6.

COORDINATE WITH ABATEMENT FOR REMOVAL OF FINISH FLOOR

CONTRACTOR TO COORDN TESTING OF WALL MATERIALS BEFORE DEMO. MSU WILL BEAR COST OF INVESTIGATION AND, IF REQD, ABATEMENT. TESTING TO BE DONE BY ENVIRONMENTAL SOLUTIONS

14.

14.

3

15.

15.

15.

15.

16.

16.

16.

16.

16.

16.

16.

16.

DEMO LEGEND

DEMOLISHED

EXISTING WALL TO REMAIN

7.

8.

8.

8.

7. A. REMOVE AND DISPOSE OF ALL FURNITURE (INCLUDING LECTERN). REMOVE AND DISPOSE OF WALL-MOUNTED PENCIL SHARPENER & CLOCK (IF APPLICABLE).

B. COORD W/ABATEMENT CONTRACTOR FOR REMOVAL OF WHITEBOARDS. C. REMOVE PROJECTOR AND SCREEN - GIVE TO MSU AV.D. PATCH AND PREP ALL WALLS FOR PAINT UNLESS OTHERWISE INDICATED.E. VERIFY ALL CONDITIONS AND COORDINATE WITH ALL DISCIPLINES OF CONTRACT.

UNDOCUMENTED FIELD CHANGES MAY HAVE OCCURRED AND ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT WHEN DISCOVERED.

F. WHERE DEMOLITION IS INDICATED, WALLS SHALL BE REMOVED AND CEILING SHALL BE PATCHED, REPAIRED AND PAINTED TO MATCH EXISTING.

G. UNLESS DEMOLITION IS INDICATED, PATCH AND PROTECT EXISTING CEILING.H. COORDINATE ALL MECHANICAL, ELECTRICAL, FIRE SYSTEMS, COMMUNICATIONS AND UTILITY

SHUT-DOWNS WITH OWNER PRIOR TO REMOVING AND OR RELOCATING, PER MSU REQUIREMENTS.

I. ALL DEMOLITION DRAWINGS ARE INTENDED TO SHOW GENERAL SCOPE OF WORK WITHIN THE INTENT OF THE PROJECT AND ARE NOT INTENDED TO EXCLUDE ANY DEMOLITION WORK NECESSARY FOR PRIOR COMPLETION OF THE WORK OUTLINED IN THE PROJECT DOCUMENTS. CONTRACTOR SHOULD ASSUME ADDITIONAL MINOR DEMOLITION ITEMS NOT SHOWN ON PLANS, NO ADDITIONAL PAYMENT WILL BE MADE FOR SUCH MINOR ELEMENTS.

J. THESE DRAWINGS INDICATE STRUCTURAL AND NON-STRUCTURAL DEMOLITION THAT IS TO OCCUR TO MAKE WAY FOR NEW CONSTRUCTION. ADDITIONAL STRUCTURAL DEMOLITION WORK, CONSTRUCTION OR SHORING REQUIRING COORDINATION WITH NEW STRUCTURAL INS INDICATED ON THE STRUCTURAL DRAWINGS.

K. SEE MECH. AND ELEC. DEMOLITION PLANS FOR SPECIFIC DEMO OF MECHANICAL AND ELECTRICAL SYSTEMS.

L. SEE HAZARDOUS MATERIALS ABATEMENT REPORT FOR ADDITIONAL INFORMATION AND COORDINATION.

GENERAL DEMOLITION NOTES:

REV. DESCRIPTION DATE

REVIEWED BY:DRAWN BY:

SHEET

DATE

SHEET TITLE

MO

NT

AN

AST

AT

E U

NIV

ER

SIT

Y

MSU-CPDCMONTANA STATE UNIVERSITY

BOZEMAN, MONTANAPHONE: 406.994.5413

FAX: 406.994.5665

428

N. L

ast C

hanc

e G

ulch

Hel

ena,

Mon

tana

5960

140

6.44

9.20

13ph

one

ww

w.m

osai

carc

h.co

m

a r c

h i

t e c

t u

r e -

p l a

n n

i n

g -

d e

s i g

n

MSU

CL

ASS

RO

OM

RE

NO

VA

TIO

NS

2019

REI

D H

ALL

40

1,4

02

-1

00

% C

D S

ET

MosaicMosaic

DEMO PLANS - REID401, 402

A00301/23/2019

RE

ID H

AL

L R

OO

MS

401

& 4

02

PPA#18-2170

1/4" = 1'-0" REF: 1/ A300

LEVEL 4 - 401/402 DEMO PLAN1

DEMOLITION NOTES1. REMOVE WALL ("12" GYP., BLK WALL" PER ORIGINAL DRAWINGS) IN ITS ENTIRETY. COORDINATE WITH ABATEMENT

FOR TESTING OF WALL PRIOR TO DEMO.

2. PROTECT ANY & ALL STRUCTURE.

3 REMOVE EXISTING DOOR & FRAME

4. DEMOLISH WALL FOR NEW DOOR LOCATION

5. PROTECT (E) CHASE WALLS

6. REMOVE (E) WOOD PANELING & (E) FURRING STRIPS ALONG ENTIRETY OF THIS WALL

7. REMOVE (E) CEILING

8. REMOVE (E) SOFFIT. SEE MEP FOR MECHANICAL DUCTS LOCATED WITHIN SOFFITS.

9. REMOVE EXISTING AV EQUIPMENT

10. DEMO STAGE AND STRUCTURE

11. VERIFY EXISTING RISER CAN BE BUILT OVER WITH NEW RISERS

12. REMOVE EXISTING RISERS THAT DO NOT CONFORM WITH NEW RISER LAYOUT AND HEIGHTS

13. PROTECT EXISTING HVAC

14. REMOVE (E) FINISH FLOOR AND PREP FOR CARPET. COORDINATE WITH ABATEMENT FOR REMOVAL OF FINISHFLOOR.

15. REMOVE (E) WINDOW COVERINGS

16. ALTERNATE: CORE DRILL (E) SLAB (3" SLAB ON CORRUFORM PER ORIGINAL DWGS) FOR NEW IN-FLOOR POWER.SEE ELECTRICAL FOR ADDN INFO

1/4" = 1'-0" REF: 1/ A300

LEVEL 4 - REFLECTED CEILING PLAN DEMO2

1 1/2" = 1'-0"EXISTING PHOTOS - REID 4014 1 1/2" = 1'-0"

EXISTING PHOTOS - REID 4023

=2405

CLASSROOM 401-402

A315

160

CALCULATED EXIT WIDTH:

EXIT WIDTH PROVIDED:

X =

REQUIRED WIDTH:

*16"

16"

72"

80

80 0.2

32"

E.A.

T.D.

= 1

20' <

200

' (OK

AY)

C.P.E.T. = 92' < 100' (OKAY)

80

80

71'

CALCULATED EXIT WIDTH:

EXIT WIDTH PROVIDED:

X =

REQUIRED WIDTH:

*16"

16"

72"

80

80 0.2

32"

(MIN

. 35

' - 6

")36

'-0"

FIRE WALL NOTE 1

FIRE WALLNOTE 2

FIRE WALLNOTE 2

FIRE WALL NOTE 3

EXTERIOR MASONRY WALL

OPEN EXIT STAIR

ENCLOSED EXIT STAIRDOWN HALLWAY

OPOEN EXIT STAIR

A

A

SUMMARY CODE REVIEW SEE CODE PLAN, THIS SHEET

OCCUPANCY CLASSIFICATION: BUSINESS GROUP BEDUCATIONAL OCCUPANCIES FOR STUDENTS ABOVE 12TH GRADE

TYPE OF CONSTRUCTION: IIIB

SPRINKLER SYSTEM: NONE EXISTING NONE PROPOSED

PROPOSED SIZE:MAINTAIN EXISTING SIZE 968 SQ FT

OCCUPANT LOADS:BUILDING SPACES:THIS PROJECT IS NOT CHANGING BUILDING AREA OR OCCUPANCY TYPE. THEREFORE IS NOT INCREASING OCCUPANT LOAD

BUILDING SUMMARY

THIS PROJECT SHALL COMPLY WITH THE LATEST EDITION OF CODES ADOPTED BY THE STATE OF MONTANA AND THE CITY OF BOZEMAN:

2012 INTERNATIONAL BUILDING CODE (IBC)2012 INTERNATIONAL MECHANICAL CODE (IMC)2012 INTERNATIONAL FUEL GAS CODE (IFGC)2012 UNIFORM PLUMBING CODE (IAMPO)2014 NATIONAL ELECTRICAL CODE (NEC)2012 INTERNATIONAL FIRE CODE (IFC)2012 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)

APPLICABLE BUILDING CODES

PROJECT DESCRIPTION:CLASSROOM REMODEL AT THE MONTANA STATE UNIVERISTY

EXITING, MAIN FLOOR:THIS PROJECT IS AN INTERIOR REMODEL PROJECT AND MEETS DEFINITON OF IEBC LEVEL 2 ALTERATION (SECTION 805 MEANS OF EGRESS, SECTION 805.1 SCOPE)

EXIT ACCESS ARRANGEMENTREQUIREMENTS FOR LEVEL 2 ALTERATION DOES NOT APPLY AS 3RD FLOOR OF BUILDING IS OCCUPIED BY SINGLE TENANT.

TRAVEL DISTANCESECTION 805.4.1.1 OCCUPANT LOAD AND TRAVEL DISTANCE: IN ANY WORK AREA, ALL ROOMS AND SPACES HAVING AN OCCUPANT LOAD GREATER THAN 50 OR IN WHICH THE TRAVEL DISTANCE TO AN EXIT EXCEEDS 75 FEET SHALL HAVE A MINIMUM OF TWO EGRESS DOORWAYS- DOES NOT APPLY.

MEANS OF EGRESSSECTION 704.1 MEANS OF EGRESS GENERAL: ALTERATIONS SHALL BE DONE IN A MANNER THAT MAINTAINS THE LEVEL OF PROTECTION PROVIDED FOR THE MEANS OF EGRESS.THE EXISTING MEANS OF EGRESS IS BEING REMODELED TO SATISFY ADA REQUIREMENTS ONLY; APPROXIMATE LOCATION WILL REMAIN THE SAME.

EXIT SIGNSTHIS PROJECT IS NOT CHANGING EXISTING EXIT SIGNS.

REFERENCE SYMBOLS:

SCALE

SECTIONS / WALL SECTIONS

DETAIL CALLOUT

INTERIOR ELEVATIONSROOM NAME, NUMBER, AND AREA

GRID LINES:NUMBERS LEFT TO RIGHTLETTERS TOP TO BOTTOM

ELEVATION TAG,TYP. MAIN FLOOR = 100' - 0"

DRAWING TITLE

FIRE EXTINGUISHER, SEE CODE PLANS

SHEET NUMBER

DRAWING NUMBER

SHEET NUMBER

DRAWING NUMBER

SHEET NUMBER

DRAWING NUMBER

FE

FE

WITH CABINET

WALL-HUNG, NO CABINET

A1-01

13

13

13

13

View Name1/8" = 1'-0"23

1

A101 SIM

A101

1

SIM

Room name

150 SF101

##

##

NameElevation

1

A101 SIM

Room name

101150 SF

INDICATES SIGN TYPE AND LOCATION.

FE INDICATES FIRE EXTINGUISHER LOCATION - ALL EXTINGUISHERS ARE EXISTING

SEE SPECIFICATIONS FOR MORE SPECIFIC SIGNAGE DETAILS, DIMENSIONS, FONT, COLORS, MATERIALS, ETC. SIGNAGE INDICATED ON CODE PLAN SHALL COMPLY WITH ICC A117.1.

A

EXIT SIGN. ARROW INDICATES DIRECTION OF TRAVEL, SHADED ARE INDICATES ILLUMINATED FACE. STEM INDICATES WALL MOUNTED. CEILING MOUNTED OTHERWISE.

CODE COMPLIANCE LEGEND

ROOM AREA (SF)

OCCUPANT LOAD500100

ACCUMULATIVE OCCUPANT LOAD

FLOOR AREA PER OCCUPANT

SUM OF OCCUPANTS AT THIS LOCATION ALONG MEANS OF EGRESS

COMMON PATH OF EGRESS TRAVEL

=B 5

OCCUPANCY CLASSIFICATION

EGRESS WIDTH PER OCCUPANT

EXIT ACCESS TRAVEL DISTANCE

PANIC EXIT DEVICE REQUIRED

MAX. DIAGONAL DIMENSION OF AREA

DOOR SEPARATION DISTANCE PROVIDED

ROOM OCCUPANCIES, AREAS & OCCUPANT LOADS

EXIT WIDTHS

EXITS & EXIT ACCESS

DOOR SEPARATIONS

ROOM NAME

12

CALCULATED EXIT WIDTH:

EXIT WIDTH PROVIDED:

X =

REQUIRED WIDTH:

*60"

60"

0"

300

300 0.2

0"

1. PRELIMINARY CODE ANALYSIS BASED ON 2012 IBC. BUILDING IS NOT COMPLIANT, HOWEVER, THIS PROJECT DOES NOT CHANGE OCCUPANCY OR TOTAL OCCUPANT LOAD

2. BUILDING AREAS INDICATED ARE FOR CODE ANALYSIS ONLY - REFER TO FLOOR PLANS FOR CONSTRUCTION DIMENSIONS.

3. FIRE PROTECTION: THE ORIGINAL STRUCTURE WAS NOT CLASSIFIED AS 1-HOUR. HOWEVER THE ORIGINAL DETAILING APPEARS TO CREATE ASSEMBLIES THAT ARE SIMILAR TO 1-HOUR ASSEMBLIES FOR FLOOR-CEILNG AND ROOF-CEILING. THIS PROJECT IS PROPOSING TO MAINTAIN THAT APPROACH IN UTILIZING AN ASSEMBLY SIMILAR TO UL 1-HOUR ASSEMBLIES. AN EXACT MATCH TO A UL SYSTEM IS NOT POSSIBLE DUE TO EXISTING STRUCTURE. THIS PROJECT REMOVE THE EXISTING SUSPENDED PLASTER CEILING AND REPLACES IT WITH A 5/8" X GYPSUM MEMBRANE PROTECTING THE STRUTURE AND THEN USING A NON-RATED LAY-IN CEILING BELOW THAT ASSEMBLY.

GENERAL CODE COMPLIANCE NOTES

1HR RATED WALLS. WALLS ARE EXISTING AND ARE CONSTRUCTED OF MASONRY. SEE PLAN FOR NOTES

FIRE WALL NOTE 1

FIRE WALL NOTE 2

FIRE WALL NOTE 3

EXISTING 12" GYPSUM BLOCK WALL. WALL BELIEVED TO BE CONTINUOUS FROM DECK TO ROOF DECK. PROJECT WILL FILL ANY DISCOVERED VOIDS AND PROVIDE RATED PENETRATIONS IF NON-RATED PENETRATED ARE DISCOVERED UPON DEMOLITION

EXISTING 12" MASONRY CORRIDOR WALL. WALL BELIEVED TO BE CONTINUOUS FROM DECK TO ROOF DECK. PROJECT WILL FILL ANY DISCOVERED VOIDS AND PROVIDE RATED PENETRATIONS IF NON-RATED PENETRATED ARE DISCOVERED UPON DEMOLITION. NEW DOORS TO BE RATED

EXISTING 4" MASONRY SHAFT WALL. WALL BELIEVED TO RUN ABOVE CEILING LINE ONLY. SHAFT CONTAINS DUCTWORK. SHAFT WALL TO BE EXTENDED TO ROOF DECK. NEW FIRE/SMOKE DAMPER TO BE INSTALLED WHERE DUCTWORK PENETRATES SHAFT WALL ABOVE CEILING.

1. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ALL CONDITIONS OF THE EXISTING SITE.

2. RESPONSIBILITY FOR ON-SITE COORDINATION OF CONSTRUCTION ACTIVITIES IS WITH THE GENERAL CONTRACTOR.

3. ALL SHOP DRAWING DIMENSIONS TO BE CHECKED AND VERIFIED IN THE FIELD BY THE CONTRACTOR WHO WILL BE RESPONSIBLE FOR SAME.

4. GENERAL CONTRACTOR IS RESPONSIBLE FOR PATCHING OF ANY SURFACES DAMAGED DURING THE CONSTRUCTION PROCESSES. SURFACES ARE TO BE PATCHED FLUSH WITH EXISTING. MATCH EXISTING ADJACENT FINISH OR APPLY NEW FINISH AS SCHEDULED.

5. GENERAL CONTRACTOR TO COORDINATE ALL CUTTING AND PATCHING REQUIRED BY WORK OF ALL TRADES AND AS APPROVED BY ARCHITECT/ ENGINEER.

6. GENERAL CONTRACTOR TO PROVIDE ALL REQUIRED BLOCKING, ANCHORAGES FOR ACCESSORIES, MILLWORK, TRIM, GRAB BARS, CABINETS, SHELVING, TOILET ACCESSORIES, HANDRAILS, OTHER FLUSH OR SEMI-RECESSED EQUIPMENT, MECHANICAL AND ELECTRICAL ITEMS, OR AS SPECIFIED.

7. IN GENERAL, REPETITIVE DETAILS DRAWN ARE SHOWN IN FULL ONLY ONCE. REPETITIONS MAY NOT BE COMPLETE IN EVERY DETAIL AS SHOWN IN THE ORIGINAL DETAIL.

8. PARTITIONS ARE LOCATED BY ONE OF THE FOLLOWING METHODS:9. a) WHERE POSSIBLE, BY RELATIONSHIP TO ADJACENT STRUCTURE.10. b) TYPICAL RELATIONSHIP TO LARGE SCALE DETAILS.11. c) BY DIMENSION FROM STRUCTURE OR PARTITION ALREADY LOCATED.12. d) BY DIMENSION FROM GRID LINES.13. e) DIMENSIONS ARE TO FACE OF STUD.14. DIMENSIONS ARE SHOWN ON THE DRAWINGS. DO NOT SCALE THE DRAWINGS.15. ALL HEIGHTS ARE DIMENSIONED FROM THE TOP OF SUBFLOOR UNLESS NOTED OTHERWISE.16. EDGE TRIM AROUND ALL EDGES OF GYPSUM BOARD WALLS ABUTTING OTHER MATERIALS. LEAVE

1/4" GAP FROM WALL FOR SEALANT.17. WHERE COLUMNS AND STUD WALLS ALIGN, GYPSUM BOARD TO BE CONTINUOUS OVER COLUMNS

OR BOXED AROUND COLUMN IF COLUMN PROJECTS BEYOND WALL.18. GYPSUM BOARD IN TOILET AREAS AND OTHER AREAS INDICATED AS "WET AREAS" TO BE WATER

RESISTANT GYPSUM BOARD.19. BRING TO THE ATTENTION OF THE ARCHITECT ANY CONDITION OR AREA OF FINISH THAT IS IN

QUESTION OR NOT NOTED.20. SEAL OPENINGS IN FLOOR AROUND DUCTS, PIPES, VENTS, SOILPIPES, TRAPS, CONDUIT, ETC.

ACCORDING TO DETAILS & SPECIFICATIONS.21. ALL PENETRATIONS THROUGH WALLS ABOVE CEILING AND BELOW STRUCTURE ARE TO BE CLOSED

TIGHT AROUND PENETRATION. USE FIRESAFING WHERE FIRE-RATED WALLS AND FLOOR/CEILINGS ARE PENETRATED. SEE DETAILS AND SPECIFICATIONS.

22. DUST BARRIERS MUST BE INSTALLED WHEREVER NEW WORK IS ADJACENT TO OCCUPIED AREAS. BARRIERS MUST BE SEALED TO INSURE NO DUST TRANSMISSION TO OCCUPIED SPACES.

23. CONTRACTOR TO VERIFY ALL EQUIPMENT SIZES AND ROUGH-IN NEEDS AND ADJUST TO EXISTING CONDITIONS PRIOR TO BEGINNING WORK.

24. SEE MECHANICAL & ELECTRICAL FOR ADDITIONAL PLACEMENT OF SLEEVES & HANGERS REQUIRED BY WORK.

25. ALL MECHANICAL AND ELECTRICAL LINES TO BE INSTALLED TIGHT TO STRUCTURE WHERE POSSIBLE.

26. HEATING, PLUMBING AND ELECTRICAL PLANS WHERE SHOWN DIAGRAMMATICALLY ARE INTENDED TO INDICATE CAPACITY, SIZE AND LOCATION AND GENERAL ARRANGEMENTS. ALL NECESSARY FEATURES OF RELATED CONSTRUCTION WILL BE REQUIRED AS IF SHOWN IN DETAIL.

27. WHERE MECHANICAL AND ELECTRICAL EQUIPMENT LOCATIONS CONFLICT ELECTRICAL, LIGHT FIXTURE LOCATIONS SHALL TAKE PRECEDENCE.

28. WHERE PLUMBING OCCURS IN STUD WALL WITH HORIZONTAL OR VERTICAL PIPING, STUDS SHALL BE CONSTRUCTED DEEP ENOUGH TO ACCOMMODATE PIPING. SAME FOR ALL ELECTRICAL PANELS.

29. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NEW MATERIALS (U.N.O.) AND QUALIFIED CRAFT PERSONS TO COMPLETE THE WORK.

30. CONSTRUCTION DOCUMENTS SHOW THE DESIGN INTENT OF THE PROJECT AND MAY NOT SHOW MINOR DETAILS OF PROPOSED INSTALLATIONS. THE INCLUSION OF THESE MINOR DETAILS IS IMPLIED TO PROVIDE A COMPLETE PROJECT AND ARE TO BE INCLUDED AS A PART OF A BID.

31. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSPECT EXISTING CONDITIONS PRIOR TO PROCEEDING WITH EACH INSTALLATION OR PART OF THE WORK. DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT PRIOR TO PROCEEDING.

32. THE GENERAL CONTRACTOR IS TO COORDINATE THE INSTALLATION OF MATERIALS AND WORK OF OTHERS WHO ARE NOT SUB-CONTRACTORS TO THE G.C., YET ARE REQUIRED TO PROVIDE A COMPLETED PROJECT. AREAS OF WORK REQUIRING COORDINATION INCLUDE BUT ARE NOT LIMITED TO THOSE INDICATED AS N.I.C. ON THE CONSTRUCTION DOCUMENTS.

33. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR COORDINATION OF WORK.34. IN THE CASE OF CONTRADICTIONS BETWEEN DRAWINGS OR BETWEEN DRAWINGS AND

SPECIFICATIONS, ASSUME THE MORE COSTLY APPROACH FOR BIDDING PURPOSES. BRING ALL CONTRADICTIONS TO THE ATTENTION OF THE ARCHITECT.

35. THE CONSTRUCTION DOCUMENTS CONSIST OF THE CONSTRUCTION DRAWINGS AND SPECIFICATIONS INCLUSIVELY. SOME ITEMS MAY BE SHOWN ONLY ON THE DRAWINGS, OR INDICATED ONLY IN THE SPECIFICATIONS. FOR EXAMPLE, THE SPECIFICATIONS MAY SAY TO PAINT ALL EXPOSED STRUCTURAL STEEL, BUT THIS MAY NOT BE CALLED OUT ON ALL OF THE DRAWINGS.

36. ALL WORK SHALL COMPLY WITH STATE AND LOCAL CODES. CONTRACTOR SHALL INSURE FULL COMPLIANCE WITH FLAME SPREAD REQUIREMENTS.

37. CONTRACTOR SHALL PROMPTLY REMOVE ALL WASTE MATERIALS AND LEAVE PREMISES AND SITE CLEAN.

38. THE CONTRACTOR SHALL PROVIDE ALL CEILING AND/OR WALL ACCESS PANELS/DOORS AS REQUIRED BY THE AIR CONDITIONING, PLUMBING & ELECTRICAL SYSTEMS, PROVIDE APPROVED ASSEMBLIES W/ SELF-CLOSING DEVICES IN RATED CONSTRUCTION. (PAINT TO MATCH ADJACENT WALL COLOR)

39. ALL PENETRATIONS OF FIRE RESISTIVE CONSTRUCTION SHALL BE PROTECTED WITH APPROVED FIRE ASSEMBLIES.

40. ELECTRICAL OUTLETS AND LIGHTING ARE ONLY SHOWN SPORATICALLY ON ARCHITECTURAL "A" SHEETS WHERE PLACEMENT OF SUCH IS CRITICAL TO PARTICULAR AESTHSTICS. ELECTRICAL INDICATIONS ON "A" SHEETS ARE NOT MEANT TO BE COMPLETE OR EXAUSTIVE. SEE ELECTRICAL DRAWINGS FOR ALL ELECTRICAL AND DATA FEATURES.

DRAWING SET NOTE: THESE DRAWINGS ARE TO BE UTILIZED AS A COMPLETE SET FOR BIDDING AND CONSTRUCTION. INDIVIDUAL SECTIONS OF DRAWINGS SHOULD NOT BE SEPARATED FROM THE ENTIRE SET. IMPORTANT NOTES FOR ONE AREA OF WORK MAY BE INCLUDED IN OTHER AREAS IN THE DRAWINGS. ALL CONTRACTORS AND SUPPLIERS MUST REVIEW ENTIRE DRAWING SET AND SPECIFICATIONS.

GENERAL NOTES:

THE GENERAL CONDITIONS TO THE CONTRACT FOR THE CONSTRUCTION OF BUILDINGS: THE MONTANA STATE UNIVERSITY GENERAL CONDITIONS TO THE CONTRACT FOR CONSTRUCTION, HEREINAFTER REFERRED TO AS THE GENERAL CONDITIONS, IS HEREBY MADE A PART OF THE ARCHITECTURAL SPECIFICATIONS.1. CONTRACT DOCUMENTS INCLUDE THE ARCHITECT'S DRAWINGS, SPECIFICATIONS, GENERAL

CONDITIONS, AGREEMENT (BUILDING CONTRACT) AND ALL ADDENDA. THEY ARE TO INCLUDE ALL LABOR, EQUIPMENT, AND MATERIALS NECESSARY FOR THE PROPER EXECUTION OF THE WORK EXCEPT AS MAY BE SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS OR FOR WHICH SEPARATE PRICES MAY BE ASKED IN THE BID PROPOSAL.

2. REGULATIONS, TAXES AND PERMITS: THE WHOLE OF THE WORK IS TO BE EXECUTED IN STRICT ACCORDANCE WITH THE REGULATIONS AND CODES OF THE GOVERNMENTAL AGENCIES WHOSE JURISDICTION IS APPLICABLE.

GENERAL CONDITIONS:IN inchINCL includedINFO informationINSUL insulationINT interiorIWA/IW interior wall assemblyJAN janitorJST joistJT jointLAV lavatoryLF lineal footLTG lightingLVR louverM men'sMNFR/MANUF. manufacturerMAT materialMAX maximumMECH mechanicalMC medicine closetMDF medium density fiber boardMEMB membraneMEZZ mezzanineMH man holeMIN minimumMIRR mirrorMISC miscellaneousMO masonry openingMTL metalMULL mullionN northNA not applicableNAT naturalNIC not in contractNO numberNTS not to scaleOA over allO.C. on centerOD outside diameterOH overhead/opposite handOPNG openingOPP oppositePART.BD. particle boardPART’N/PART partitionPC precast concretePL platePLAM plastic laminatePLAST plasticPLWD plywoodPND paper napkin dispenserPNL panelPR pairPSL parallel strand lumberPT pointPTD paper towel dispenserPTD/R paper towel dispenser/receptaclePVMT pavementP.V.C. polyvinylchlorideQTY quantityR/RAD radiusR riserRA roof/ceiling assemblyRB rubber baseRD roof drainRDWD redwoodRE regardingREC recessedREF referenceREFR refrigeratorREINF reinforcingREQD/REQ requiredRES resilientRM roomRO rough openingRV roof ventR&S rod and shelfS southSACT suspended acoustical ceiling tileSAT suspended acoustical tile ceilingSC solid coreSCD seat cover dispenserSCHED scheduleSD soap dispenserSECT sectionSF square feetS.G. supply grillSGL safety glassSHLVS shelvesSHLVNG shelvingSHT sheetSHTG sheathingSHWR showerSIM similarSIM. similarS.I.P. structural insulated panelSLNT sealantSM surface mountedSOG slab on gradeS.STL./SS stainless steelS&P shelf and poleSPEC specificationsSS service sinkSTD standardSTL steelSTOR storageSTRUCT/STRUC structuralSUBFLR subfloorSUSP suspendedS&V stain and varnishSV sheet vinylSY square yardT tread/thermostatTB towel barTEL telephoneTEMP temperatureT&G tongue and grooveT.ALUM. tubular aluminumT.B. test boreTHK thickTHRU throughT.J.I./TJI Truss Joist IncorporatedT.O. top ofT.O.B. top of beamTOC top of concreteT.O.P. top of plateT.O. FTG top of footingT.O.S. top of steelT.O. SL. top of slabT.O.W. top of wallTP toilet paper holderTPD toilet paper dispenserTPG toppingTR/TRD treadT.S. tubular steelTV televisionTYP typicalUBC uniform building codeUG undergroundUH unit heaterUNO unless noted otherwiseUR urinalUV unit ventilatorVAC vacuum outletVAR variesVB vapor barrierVCT vinyl composition tileVEN veneerVERT verticalVEST vestibuleVG vertical grainVIN vinylVP veneer plasticVT vinyl tileVWC vinyl wall coveringW west/women/widthW/ withW/O with outWB wood baseWC water closetWD woodW/D washer/dryerWGW windowWGL wire glassWH water heaterWM wire meshWNDW/WDW windowWP waterproofWR water resistantWS weatherstripWSCT wainscotWT weightWWF welded wire fabricWWM welded wire meshX byYH yard hydrantYD yard

@ atA.B. anchor boltAC asphaltic concreteA/C air conditioningACC PNL access panelACOUST acousticalACT acoustical ceiling tileAD area drainADJ adjacentA.F.F. above finished floorA.I.B. air infiltration barrierALT alternateALUM aluminumANOD anodizedAPPROX approximateAPPRD approvedARCH architectAUTO automaticBBD bulletin boardBD boardBITUM bituminuousBL building lineBLDG buildingBLK blockBLKG blockingBLDG buildingBLKG blockingBM beam/bench markBO by ownerB.O. bottom ofBOT bottomBRK brickBRG bearingB/S building standardBSBD baseboardBTW betweenBTM/BOTT bottomBTWN betweenB.O.W. bottom of wallBU built upCAB cabinetCAP capacityCB catch basinCBD chalk boardCB-ICF cement based insulated concrete formCD ceiling diffuserC.F. cement fiber (siding and trim)/cubic feetCL centerlineC.B. catch basinC.C. center to centerCDX exterior grade plywoodC.T. ceramic tileCG ceiling grill/corner guardCH channelCI cast iron/cubic incheseCJ control jointCLG ceilingC.L.L. contract limit lineCL center lineCLO closetCLR clearCMU concrete masonry unitCMNT cementCMT ceramic mosaic tileCO clean outCOL/COLS column/columnsCONC concreteCOND conditionCONF conferenceCONN connectionCONST constructionCTRD centeredCONT continuousCONTR contractorCORR corridorCPT carpetCR ceiling registerCT ceramic tileCTR counterCUH cabinet unit heaterCW cold waterCY cubic yardDBL doubleDEPT departmentDF drinking fountainDIA diameterDIAG diagonalDIM dimensionDISP dispenserDL dead loadDN downDP demountable partitionDR doorDWR drawerDS downspoutDTL/DET detailDWG drawingE eastEA eachEIFS exterior insulation finish systemE.J. expansion jointEL/ELEV elevation - height/elevatorELEC electricalENCL enclosureEO electrical outletEP electrical panelEQ equalEQUIP equipmentEWC electrical water coolerEWH electrical water heater(E)/EXIST existingEWC electrical water coolerEWH electrical water heaterEXH exhaustEXP expansionEXT exteriorEWA/EW exterior wall assemblyFA fire alarm/floor-ceiling assemblyFABR fabricateFAH fire alarm hornFAS fire alarm stationFBR face brickFD floor drainFDN/FDTN foundationFFHB frost free hose bibFG finish gradeFH fire hydrantFIN. FLOOR top of floor sheathingFIN finishFIO furnished and installed by ownerFIX/FXTR fixtureF.O. face ofFDN foundationFEC fire extinguisher cabinetFF finished floorFLR/FL floorFLUOR fluorescentFND feminine napkin dispenser/disposalFOC face of concreteFOIC furnished by owner and installed byFOS face of studFOW face of wallFT foot or feetFTG footingFTIC furnished by tenant & installed by contractorFE fire extinguisherGA gaugeGB grab barGAF brand name roofing productGALV galvanized G.C. general contractorGEN generalGI galvanized ironGL glassGLU LAM or G.L.B. glue laminated beamGRD grade/gridGS galvanized steelGWB gypsum wall boardGYP gypsumHB hose bibHC hollow core/handicappedHD BD Hard boardHDR headerHOR horizontalHP high pointHR hourHT heightHTG heatingHVAC heating, ventilation, air conditioningHW hot water

ABBREVIATIONS:

A TACTILE SIGN COMPLYING WITH ICC A117.1.SEE CODE PLANS FOR LOCATIONS.

BRAILLE - 48" MIN. & 60" MAX. A.F.F.

CHARACTER HEIGHT 5/8" MIN., 2" MAX. RAISED 1/32"

A

REV. DESCRIPTION DATE

REVIEWED BY:DRAWN BY:

SHEET

DATE

SHEET TITLE

MO

NT

AN

AST

AT

E U

NIV

ER

SIT

Y

MSU-CPDCMONTANA STATE UNIVERSITY

BOZEMAN, MONTANAPHONE: 406.994.5413

FAX: 406.994.5665

428

N. L

ast C

hanc

e G

ulch

Hel

ena,

Mon

tana

5960

140

6.44

9.20

13ph

one

ww

w.m

osai

carc

h.co

m

a r c

h i

t e c

t u

r e -

p l a

n n

i n

g -

d e

s i g

n

MSU

CL

ASS

RO

OM

RE

NO

VA

TIO

NS

2019

REI

D H

ALL

40

1,4

02

-1

00

% C

D S

ET

MOSAICMOSAIC

GENERAL & CODEANALYSIS - REID

401,402

A00801/23/2019

RE

ID H

AL

L R

OO

MS

401

& 4

02

PPA#18-2170

1/8" = 1'-0" REF: 1/ A300

CODE ANALYSIS - REID - 401, 4021

MONTANA STATE UNIVERSITY REPRESENTATIVE, MOSAIC ARCHITECTURE AND THE CITY OF BOZEMAN BUILDING OFFICIALS MET ON DECEMBER 8, 2018 TO DISCUSS THIS PROJECT. MSU STATED THEY ARE WORKING ON FUNDING FOR A FIRE SPRINKLER SYSTEM, BUT THAT SYSTEM WILL NOT BE INSTALLED BEFORE THIS REMODEL PROJECT. ALL PARTIES RECOGNIZE THE IMPORTANCE OF INSTALLING A SPRINKLER SYSTEM. MSU REQUESTED THIS PROJECT BE ALLOWED TO MOVE AHEAD PRIOR TO SPRINKLER SYTEM INSTALLATION. THE CITY OFFICIALS AGREE THAT SINCE THIS PROJECT DOES NOT CHANGE OCCUPANCY AND DOES NOT IMPACT OVER 50% OF THE FLOOR, IT IS NOT REQUIRED TO UPGRADE MAJOR CODE ELEMENTS SUCH AS SPRINKLERS AND EXIT STAIRS. HOWEVER, THE CITY FELT THEY WOULD REQUIRE VERIFICATION OF OR UPGRADES TO SOME OF BASIC LIFE-SAFETY IMPROVEMENTS. THE CITY INDICATED THEY WOULD REQUIRE:• ALL WORK ON THIS PROJECT TO IMPROVE THE EXISTING CONDITION, THIS WOULD INCLUDE MAINTAINING A SIMILARLY PROTECTED ROOF-CEILING ASSEMBLY• EXISTING DUCTWORK SHAFT SHOULD BE EXTENDED TO DECK AND DUCT PENETRATIONS PROVIDED WITH DAMPERS IN ALL ACCESSIBLE LOCATIONS WITHIN THESE ROOMS.• VERIFY EMERGENCY LIGHTING IS PROVIDE IN THE BUILDING COMMON AREAS ALONG THE ENTIRE EXIT PATH FROM THE SPACES BEING REMODELED. MSU CONFIRMED EMERGENCY

LIGHTING IS IN PLACE.• VERIFY EXIT LIGHTS ARE PROVIDED IN THE BUILDNG COMMON AREAS ALONG THE ENTIRE EXIT PATH FROM THE SPACES BEING REMODELED: MSU CONFIRMED EXIT LIGHTS ARE IN

PLACE• REPLACE HALLWAY DOORS WITH FIRE-RATED DOORS THAT PROVIDE ADEQUATE EXITING WIDTH AND TWO EXITS PROPERLY SEPERATED

ANOTHER SERIOUS CODE ISSUE IN THE EXISTING BUILDING IS THAT EACH ROOM 401/402 HAS OVER 50 OCCUPANTS AND REQUIRES TWO EXITS. EACH ROOM HAS ONLY ONE EXIT, AND NEITHER ROOM HAS ADEQUATE WIDTH TO PROVIDE 2 EXITS AT THE REQUIRED SEPERATION DISTANCE. THIS PROJECT WILL COMBINE THE ROOMS AND MOVE ONE OF THE EXIT DOORWAYS SO THE COMBINED ROOM HAS THE NUMBER AND SEPERATION REQUIRED FOR THE ROOM OCCUPANT LOAD.

TO MEET THE CITY REQUESTS TO IMPROVE THE LIFE SAFETY OF THIS ROOM, MSU HAS CONFIRMED THAT EMERGENCY LIGHTING AND EXITS LIGHTS ARE IN PLACE (IF IT IS DISCOVERED THERE ARE DEFICIENCIES IN EITHER SYSTEM, MSU WILL UPGRADE THOSE) , AND THIS PROJECT WILL CORRECT ROOM EXIT ARRANGEMENT, DOOR RATING, AND IMPROVE DUCT SHAFT RATING/CONTINUITY.

3" = 1'-0" SIGNAGE3

3

3

2

2

1

1

2405 SF

CLASSROOM

401-402

A2003

2

1

4

2

A300

GG

II

KK

1

A300A400

9

A400

5 A400

8A400

12

A200

6

A500 2

SF1

24'-9

"8'

-1"

3

A300

8

A400

6

A400

6

A400

6

A400

6

401A

401B

A400

11

Sim

A200

5

1'-1

1 3/

8"

2'-7 3/4"

2'-6

1/2

"2'

-5"

2'-7"

1'-1

1"

2'-7 3/4"

7

A400

9

Sim

CLEAN GLASS AND FRAME, REMOVE CAULK & RECAULK PERIMETER

CLEAN GLASS AND FRAME, REMOVE CAULK & RECAULK PERIMETER

CLEAN GLASS AND FRAME, REMOVE CAULK & RECAULK PERIMETER

3

A400

NEW DOORS

NEW DOORS

3

3

2

2

1

1

2

A300

GG

II

KK

1

A300

12

A401

3

A300MECH.

MECH.

EQEQ

EQEQ

ACOUSTIC CEILING GRID

ACOUSTIC CEILING GRID

VERIFY PROJECTOR MOUNTING HEIGHT/LOCATION FOR SCREEN ALIGNMENT AND MODEL TYPE. PROVIDE POWER AND AV CONNECTION RUNS TYP.

VERIFY PROJECTOR MOUNTING HEIGHT/LOCATION FOR SCREEN ALIGNMENT AND MODEL TYPE. PROVIDE POWER AND AV CONNECTION RUNS TYP.

VERIFY PROJECTOR MOUNTING HEIGHT/LOCATION FOR SCREEN ALIGNMENT AND MODEL TYPE. PROVIDE POWER AND AV CONNECTION RUNS TYP.

VERIFY PROJECTOR MOUNTING HEIGHT/LOCATION FOR SCREEN ALIGNMENT AND MODEL TYPE. PROVIDE POWER AND AV CONNECTION RUNS TYP.

COORDINATE MECHANICAL GRILL LOCATIONS. REMOVE ACOUSTIC BACKING IN METAL SOFFITS FOR UNOBSTRUCTED AIR FLOW THROUGH PERFORATED PANELS TYP. S.M.D.

D2 D2 D2D2

D1 D1 D1 D1

D1D1D1D1

D1 D1 D1 D1

D2D2D2D2

D1 D1 D1 D1

ACT110'-0"

ACT110'-0"

MC18'-6"

MC18'-6"

MC18'-6"

D3

D3

MC18'-6"

D3

MC18'-6"

A402

2

8

A401

SOFFIT FRAMING 1 3/8" OFFSET FROM WINDOW FRAME.

FROM

WIN

DOW

OPE

NING

SSO

FFIT

FRA

MIN

G OF

FSET

1 3

/8"

SOFFIT FRAMING 1 3/8" OFFSET FROM WINDOW FRAME.

VERI

FYFI

ELD

5'-0 5/8"

2'-4 1/4"

FACE OF SOFFIT: ONE MTL PANEL BENT @ CORNER

2'-5

5/8

"VE

RIFY

FIEL

D

3'-5 3/8"MTL PANEL DIM

EDGE OF SOFFIT FRAMING

MTL PANEL DIMENSIONS

4'-0" TYP ALL U.N.O

FIEL

D VE

RIFY

FIEL

D VE

RIFY

FIEL

D VE

RIFY

MTL

PAN

EL D

IMEN

SION

S

4'-0

" TYP

ALL

U.N

.O.

3'-4"

EDGE OF SOFFIT FRAMING

3'-4"

VERIFYFIELD

VERI

FYFI

ELD

VERI

FYFI

ELD

VERI

FYFI

ELD

MTL

PAN

EL D

IMEN

SION

S

FIEL

D VE

RIFY

1/2"

EDGE OF HORIZONTAL PANEL TO ALIGN WITH EDGE OF WINDOW

VERIFYFIELD

MTL PANEL DIMENSION

FIEL

D VE

RIFY

4'-0

" TYP

ALL

U.N

.O.

VERI

FYFI

ELD

FIEL

D VE

RIFY

5'-0 5/8" 4'-0" TYP ALL U.N.O.

5'-0 5/8"

MTL

PAN

EL D

IMEN

SION

S

MTL PANEL DIMENSIONS MTL PANEL DIMENSION

2'-5 1/8"

MTL PANEL DIMENSIONS

A402

3

4" 2'-3"

HAT CHANNEL BEYOND

4"2'

-3"

4"

4"2'

-1"

2'-2

1/2

"

HAT CHANNEL BEYOND

HAT CHANNEL BEYOND

4" 2'-3"

4"2'

-3"

3'-5 3/8"

HAT CHANNEL BEYOND

HAT CHANNEL BEYOND

FACE OF SOFFIT: ONE MTL PANEL BENT @ CORNER

FACE OF SOFFIT: ONE MTL PANEL BENT @ CORNER

2'-4 1/4"

2"

2"

A402

1

REFLECTED CEILING PLAN SHOW METAL PANEL SOFFIT ALTERNATE.ALTERNATE NOTES

BASEBID: GWB - GYPSUM WALLBOARD SOFFIT1. CONTINUOUS GWB WITH REVEAL ON FACE, SEE DETAIL.2. MODIFY FRAMING DIMENSIONS TO INCORPORATE 1 3/8" GIVEN

FOR ALTERNATE METAL PANEL SOFFIT ASSEMBLY.3. 8'6" CEILING HEIGHT AS DRAWN IN RCP TO MAINTAIN IN

BASEBID.

ALTERNATE: MC1 - METAL PANEL SOFFIT1. PERFORATED METAL PANELS WITH BAMBOO REVEALS2. SEE FINISH LEGEND FOR FINISHES3. ALTERNATE MC1 AS SPECIFIED IN DRAWINGS

REV. DESCRIPTION DATE

REVIEWED BY:DRAWN BY:

SHEET

DATE

SHEET TITLE

MO

NT

AN

AST

AT

E U

NIV

ER

SIT

Y

MSU-CPDCMONTANA STATE UNIVERSITY

BOZEMAN, MONTANAPHONE: 406.994.5413

FAX: 406.994.5665

428

N. L

ast C

hanc

e G

ulch

Hel

ena,

Mon

tana

5960

140

6.44

9.20

13ph

one

ww

w.m

osai

carc

h.co

m

a r c

h i

t e c

t u

r e -

p l a

n n

i n

g -

d e

s i g

n

MSU

CL

ASS

RO

OM

RE

NO

VA

TIO

NS

2019

REI

D H

ALL

40

1,4

02

-1

00

% C

D S

ET

MOSAICMOSAIC

FLOOR PLANS & RCP- REID 401, 402

A10001/23/2019

RE

ID H

AL

L R

OO

MS

401

& 4

02

PPA#18-2170

1/4" = 1'-0" REF: 1/ A300

FLOOR PLAN - REID 401,4021 1/4" = 1'-0" REF: 1/ A300

REFLECTED CEILING PLAN - REID 401,4022

BASEBID - MANUAL SCREENS (SCREEN BY OWNER)ALTERNATE - MOTORIZED SCREENS (SCREEN BY OWNER)SCREEN INSTALL: FINAL LOCATION TO BE FIELD VERIFIED. VERIFY WALL TYPE AND PROVIDE APPROPRIATE ANCHORS/BACKING FOR MOUNTING PER MANUFR.

PROJECTION SCREEN INSTALL:VERIFY CLEARANCE OF SCREEN BASE AND MARKERBOARD

PROJECTION SCREEN INSTALL:VERIFY CLEARANCE OF SCREEN BASE AND MARKERBOARD

3'-0

"

3'-0

"

CR1 CR1

CR1

EQ EQEQ EQ

4" BB PLY BASE

WB2 WB2 WB2 WB2

8 1/8" 1 1/2" 8 1/8"

1 1/

2"

SWITCHES

SKIMCOAT & PAINT (E) PLASTER SKIMCOAT & PAINT (E) PLASTER

CONDUIT

BASEBID - MANUAL SCREENS (SCREEN BY OWNER)ALTERNATE - MOTORIZED SCREENS (SCREEN BY OWNER)SCREEN INSTALL: FINAL LOCATION TO BE FIELD VERIFIED. VERIFY WALL TYPE AND PROVIDE APPROPRIATE ANCHORS/BACKING FOR MOUNTING PER MANUFR.

METAL PANEL SOFFITS, SEE ALTERNATE NOTES

4" BB PLY BASE

1'-3

1/2

"

6 1/

2"

7 1/

2"

4'-0

"3'

-10"

1'-3

1/2

" 1'-0

"

2'-5

"

2'-5

"5'

-5"

2'-5

"

1'-3

1/2

" 1'-0

"

3'-2

"4'

-8"

2'-5

"

2'-5

"

7 1/

2"

4'-0

"3'

-10"

1/2"

GWB PAINTED

4"4"

HAT CHANNEL BEYOND

1/2"

1'-3

1/2

"

1'-3

1/2

"

8'-5

"1"

CR1 1 1/

2" R

EVEA

L TY

P AL

L1

1/2"

6 1/

2"

1'-3

1/2

"

1'-6 3/4" 4'-0" TYP ALL U.N.O. 1 1/2" REVEAL, TYP ALL

2'-3 3/4"

FIELD VERIFY

VERIFYFIELD

3'-0

"

WB1 WB1 WB1

EQEQ EQEQ EQEQ EQEQ EQEQ EQEQ

METAL PANEL SOFFITS, SEE ALTERNATE NOTES

4" BB PLY BASE

GWB PAINTED

2'-5

"

2'-5

"

7 1/

2" 6 1/

2"

7 1/

2"

6 1/

2"

5'-5

"

2'-5

"

1'-3

1/2

"

3'-1

0"4'

-0"

4'-0

"3'

-10"

2'-5

"

2'-5

"

1'-3

1/2

" 1'-0

"

2'-5

"

1'-3

1/2

"

1'-3

1/2

"

1'-3

1/2

"

8'-5

"

3'-2

"4'

-8"

VERIFYFIELD1/2" 1/2"2'-3 3/4"

1"

1 1/

2" R

EVEA

L TY

P AL

L

1'-6 3/4"4'-0" TYP ALL, U.N.O.1 1/2" REVEAL TYP ALLVERIFYFIELD

4"4"

HAT CHANNEL BEYOND

CR1

3'-0

"

WB1 WB1 WB1

EQEQ EQEQ EQEQ EQEQ EQEQ EQEQ

3'-0

"

INFILL EXISTING OPENING WITH RATED STOREFRONT

METAL SOFFITS, SEE ALTERNATE NOTES

METAL SOFFITS, SEE ALTERNATE NOTES

CR1

CR1

CR1CR1

3'-0

"

2'-5 7/16"

401B 401A

2'-7"

3'-0

"

4" BB PLY BASE

1'-8

3/4

"5'

-4 3

/4"

1 1/2"

1 1/

2"1

1/2"

1 1/

2"

2'-6 5/8" 4'-0" TYP ALL U.N.O. FIELD VERIFY1 1/2" REVEAL TYP ALLVERIFYFIELD 7/8"

WB1WB1WB1

SURFACE MOUNTED CONDUIT. COORD FINAL LOCATION WITH ARCH

SURFACE MOUNTED CONDUIT. COORD FINAL LOCATION WITH ARCH

LIGHT SWITCHES LIGHT SWITCHES

SEE STORE FRONT TYPES FOR ADDN INFORMATION

GWB PAINTED

SKIMCOAT & PAINT (E) PLASTER

GWB PAINTED

SKIMCOAT & PAINT (E) PLASTER

A200

9

A200

9

Sim

1'-6 3/4"

1/2"

1'-8

3/4

"

3'-0

"1 1/

2"1

1/2"

1 1/

2"

5'-4

3/4

"

1"

4'-0" TYP ALL U.N.O.1 1/2" REVEAL TYP ALLVERIFYFIELD

7'-1

1 1/

2"1

1/2"

4" BB PLY BASE 4" BB PLY4" BB PLY

1 1/

2"7'

-11

1/2"

HAT CHANNEL BEYOND

4"4"

METAL PANEL SOFFITS, SEE ALTERNATE NOTES

VERIFYFIELD1'-6 3/4" 4'-0" TYP ALL U.N.O. 1 1/2" REVEAL TYP ALL

HAT CHANNEL BEYOND

METAL PANEL SOFFITS, SEE ALTERNATE NOTES

4"4"

7'-1

1 3/

16"

1 1/

2"

4" BB PLY BASE

1 1/

2"1

1/2"

1 1/

2"

3'-0

"

4" BB PLY BASE

1'-8

3/4

"5'

-4 3

/4"

1"

4" BB PLY BASE

1 1/

2"7'

-11

1/2"

7'-1

1 1/

2"

6 7/8" 6 3/4"1 1/2"

1 1/

2"

7'-1

1 1/

2"

6 3/4" 6 7/8"

1 1/2"

1 1/

2"

1" TACK STRIP

8'-0"

4'-0

"

WB1

MARKER TRAY

1" TACK STRIP

10'-0"

4'-0

"

WB2

MARKER TRAY

NOTE: MOUNTING HEIGHT - BOTTOM OF WHITEBOARD IS TO BE 3' AFFWHITE BOARD TYPESSEE PLAN AND ELEVATIONS FOR LOCATIONS. COORDINATE FINAL WHITEBOARD LOCATIONS WITH ARCHITECT BEFORE INSTALL.BASEBID: GWB - GYPSUM WALLBOARD SOFFIT

1. CONTINUOUS GWB WITH REVEAL ON FACE, SEE DETAIL.2. MODIFY FRAMING DIMENSIONS TO INCORPORATE 1 3/8" GIVEN

FOR ALTERNATE METAL PANEL SOFFIT ASSEMBLY.3. 8'6" CEILING HEIGHT AS DRAWN IN RCP TO MAINTAIN IN

BASEBID.

ELEVATIONS SHOW METAL PANEL SOFFIT ALTERNATE.ALTERNATE NOTES

ALTERNATE: MC1 - METAL PANEL SOFFIT1. PERFORATED METAL PANELS WITH BAMBOO REVEALS2. SEE FINISH LEGEND FOR FINISHES3. ALTERNATE MC1 AS SPECIFIED IN DRAWINGS

T.O.WHITEBOARD

B.O. SOFFIT

EQEQ

CUT (E) PLASTER WALL TO BURY CONDUIT.PATCH PLASTER TO MATCH (E) FINISH. SEE NOTE.

POWERED OVER ETHERNET CLOCK

NETWORK JACK, BEYOND

CONDUIT

NOTE: POSSIBLE ABATEMENT REQD; COORD W/ABATEMENT CONTRACTOR BEFORE DEMO

REV. DESCRIPTION DATE

REVIEWED BY:DRAWN BY:

SHEET

DATE

SHEET TITLE

MO

NT

AN

AST

AT

E U

NIV

ER

SIT

Y

MSU-CPDCMONTANA STATE UNIVERSITY

BOZEMAN, MONTANAPHONE: 406.994.5413

FAX: 406.994.5665

428

N. L

ast C

hanc

e G

ulch

Hel

ena,

Mon

tana

5960

140

6.44

9.20

13ph

one

ww

w.m

osai

carc

h.co

m

a r c

h i

t e c

t u

r e -

p l a

n n

i n

g -

d e

s i g

n

MSU

CL

ASS

RO

OM

RE

NO

VA

TIO

NS

2019

REI

D H

ALL

40

1,4

02

-1

00

% C

D S

ET

MOSAICMOSAIC

INTERIORELEVATIONS - REID

401, 402

A20001/23/2019

RE

ID H

AL

L R

OO

MS

401

& 4

02

PPA#18-2170

1/4" = 1'-0" REF: 1/ A100

401-402 EAST ELEVATION1 1/4" = 1'-0" REF: 1/ A100

401-402-NORTH ELEVATION2

1/4" = 1'-0" REF: 1/ A100

401-402-SOUTH ELEVATION41/4" = 1'-0" REF: 1/ A100

401-402-WEST ELEVATION3

1/4" = 1'-0" REF: 1/ A100

CENTER SOFFIT NORTH ELEVATION5

1/4" = 1'-0" REF: 1/ A100

CENTER SOFFIT SOUTH ELEVATION6

1/4" = 1'-0" REF: 1/ A100

COLUMN EAST ELEVATION7 1/4" = 1'-0" REF: 1/ A100

COLUMN WEST ELEVATION8 1 1/2" = 1'-0" REF: 3/ A200

ELEVATION CALLOUT @ CLOCK9

LEVEL 4 - AS BUILTS136'-0"

T.O. ROOF CONC SLAB148'-0"

3 2 1

2405 SF

CLASSROOM

401-402

1-HOUR RATED ASSEMBLY SEE DETAIL

ACOUSTIC CEILINGS

METAL PANEL SOFFITS, SEE ALTERNATE NOTES

WHITE BOARD SEE ELEVATIONS

CHAIR RAIL TYP.

8'-6

"10'-0

"

A300

7

Sim

RATED CLG10'-8 7/8"

ACT110'-0"

LEVEL 4 - AS BUILTS136'-0"

T.O. ROOF CONC SLAB148'-0"

GIK

2405 SF

CLASSROOM

401-402

A300

4

8'-6

"

8'-6

"

8'-6

" 10'-0

"

1-HOUR RATED ASSEMBLY SEE DETAIL

ACOUSTIC CEILINGS

METAL PANEL SOFFITS/CEILINGS, SEE ALTERNATE NOTES

WHITE BOARD SEE ELEVATIONS

EXISTING MECHANICAL SYSTEMS

RATED CLG10'-8 7/8"

ACT110'-0"

MC18'-6"

A402

6

Sim

LEVEL 4 - AS BUILTS136'-0"

T.O. ROOF CONC SLAB148'-0"

K

A401

10

Sim

A400

13

Sim

A400

16

Sim

A400

14

Sim

A401

9

Sim

A400

15

Sim

ALTERNATE METAL PANEL SOFFIT SHOWN, SEE ALTERNATE NOTES.

RATED CLG10'-8 7/8"

ACT110'-0"

LEVEL 4 - AS BUILTS136'-0"

T.O. ROOF CONC SLAB148'-0"

3 2A300

5

2405 SF

CLASSROOM

401-402

RATED CLG10'-8 7/8"

METAL PANEL SOFFITS,SEE ALTERNATE NOTSE

3

A400

13

Sim

A400

16

Sim

EXTEND FRAMING TO RATED CLG

MECHVERTCHASE

2 LAYERS 1/2" TYPE X GWBTO MAINTAIN 1 HR RATED WALL ASSEMBLY

A402

4

Sim

HORIZONTAL DUCT BEYOND

METAL PANEL SOFFIT

RATED CLG10'-8 7/8"

FIRE DAMPER LOCATION

PROVIDE FIRE CAULKED JOINT GYP TO DECK

LEVEL 4 - AS BUILTS136'-0"

T.O. ROOF CONC SLAB148'-0"

1

A401

8

MAINTAIN FIRE RATED CLG ASSEMBLY ALONG ENTIRE CLG

METAL PANEL SOFFIT, SEE ALTERNATE NOTES

1/2" SOLID SURFACE MATERIAL

EXISTING WALL

CONTIN. SEALANT JT., COLOR MATCH TO SOLID SURF. MTL.

10"

1/2"

ADHESIVE

CONTIN. SEALANT JT., COLOR MATCH TO SOLID SURF. MTL.

SQUARE EDGE

BASEBID: GWB - GYPSUM WALLBOARD SOFFIT1. CONTINUOUS GWB WITH REVEAL ON FACE, SEE DETAIL.2. MODIFY FRAMING DIMENSIONS TO INCORPORATE 1 3/8" GIVEN

FOR ALTERNATE METAL PANEL SOFFIT ASSEMBLY.3. 8'6" CEILING HEIGHT AS DRAWN IN RCP TO MAINTAIN IN

BASEBID.

SECTIONS SHOW METAL PANEL SOFFIT ALTERNATE.ALTERNATE NOTES

ALTERNATE: MC1 - METAL PANEL SOFFIT1. PERFORATED METAL PANELS WITH BAMBOO REVEALS2. SEE FINISH LEGEND FOR FINISHES3. ALTERNATE MC1 AS SPECIFIED IN DRAWINGS

REV. DESCRIPTION DATE

REVIEWED BY:DRAWN BY:

SHEET

DATE

SHEET TITLE

MO

NT

AN

AST

AT

E U

NIV

ER

SIT

Y

MSU-CPDCMONTANA STATE UNIVERSITY

BOZEMAN, MONTANAPHONE: 406.994.5413

FAX: 406.994.5665

428

N. L

ast C

hanc

e G

ulch

Hel

ena,

Mon

tana

5960

140

6.44

9.20

13ph

one

ww

w.m

osai

carc

h.co

m

a r c

h i

t e c

t u

r e -

p l a

n n

i n

g -

d e

s i g

n

MSU

CL

ASS

RO

OM

RE

NO

VA

TIO

NS

2019

REI

D H

ALL

40

1,4

02

-1

00

% C

D S

ET

MOSAICMOSAIC

SECTIONS - REID 401,402

A30001/23/2019

RE

ID H

AL

L R

OO

MS

401

& 4

02

PPA#18-2170

1/4" = 1'-0" REF: 1/ A100

CROSS SECTION - REID 401,40221/4" = 1'-0" REF: 1/ A100

LONGITUDINAL SECTION - REID 401,4021

3/4" = 1'-0" REF: 1/ A300

WALL SECTION 014

1/4" = 1'-0" REF: 1/ A100

CROSS SECTION - REID 401,13

3/4" = 1'-0" REF: 3/ A300

WALL SECTION 025 3/4" = 1'-0"WALL SECTION 036

1" = 1'-0" REF: 2/ A300

CHAIR RAIL DETAIL7

A400

10

Sim

CHAIR RAIL WITH MITER CUT CORNER

5/8" TYPE X GWB

BB PLYWOOD PANELS

2 1/2" MTL STD FRAMING

7

A300Sim

5/8" TYPE X GWB

2 1/2" MTL STD FRAMING

(E) PLASTER WALL

3

K II

(E) 12" BLK WALL

(E) PLASTER WALL

EXTEND FRAMING TO B.O. SOFFIT, SEE SECTION

FINISH REVEAL, SEE ELEVATION

2

2

I

3/4" BB PLY

1/2" BB PLY

1/2" TYPE X GWBTO ROOFDECK

NO. 24 MSG GALVANIZED STEEL COLUMN COVER

1/2" TYPE X GWB

OUTLET FOR POWER @ BOTH SIDES OF COLUMN. SED

(E) COLUMN

1 5/8" MTL STD FRAMING

1'-3 3/4"

1'-3

"

6 3/

4"1

1/2"

6 3/

4"

REVEAL EDGEGRAIN,TYP ALL CORNERS

HIDDEN FASTENERS, TYP ALL BB PLY

12

A401

2

1

1

I

3/4" BB PLY

1/2" PLYWOOD

1/2" TYPE X GWBTO DECK

1/2" TYPE X GWB

NO. 24 MSG GALVANIZED STEEL COLUMN COVER

1 5/8" MTL STD FRAMING

1 5/8" MTL STD FRAMING

(E) COLUMN

(E) EXTERIOR WALL

WRAP CORNER W/BB PLY

WRAP CORNER W/BB PLY

2 1/2"

(E) WINDOW FRAME

(E) WINDOW FRAME

2 1/2"

7"7"

1 1/

2"

REVEAL EDGEGRAIN, TYP ALL CORNERS

HIDDEN FASTENERS, TYP ALL BB PLY

FIELD VERIFY POSSIBLE CONFLICT W/MECH FLOOR GRILLE

HOLLOW METAL FRAME -PAINT

FIRE CAULK JOINT TYPICAL ALL SIDES

JAMB BEYOND

DOOR PER SCHEDULE

(E) PLASTER

11"

WINDOW UNIT

FINISH FLOOR, SEE FINISH PLAN

(E) FLOOR

SHIM

FIRE CAULKED JOINT

1/2" BB PLY

1 5/8" MTL STD FRAMING

NYLON WASHER

7/8" HAT CHANNEL

PERF METAL PANEL

3/4" BB PLY

(E) WALL

SOFFIT FRAMING S.S.D.

SOFFIT PER RCP

1"

1/2"

1/2" BB PLY. EXTEND BEHIND WHITEBOARD, TYP ALL WHITEBOARD SIDES

1 5/8" MTL STD FRAMING

3/4" BB PLY, AMBER

(E) WALL

WHITE BOARDINSTALL PER MANF RECOMMENDATION

SEE ELEVATION FOR PANEL LAYOUT1 1/

2"

1 5/8" MTL STD FRAMING

3/4" BB PLY

(E) WALL

WHITE BOARDINSTALL PER MANF RECOMMENDATION

SEE ELEVATION FOR PANEL LAYOUT

1/2" BB PLY. EXTEND BEHIND WHITEBOARD, TYP ALL WHITEBOARD SIDES

1/2" BB PLY REVEAL BACKER

1 5/8" MTL STD FRAMING

3/4" BB PLY

(E) WALL

4" BB PLY BASE

FIN FLOOR

(E) FLOOR

1/2" BB PLY

1 5/8" MTL STD FRAMING

(E) WALL

(E) WALL

3/4" BB PLY1/2"

5/8" TYPE X GWB

2 1/2" MTL STD FRAMING

CHAIR RAIL, SEE ELEVATION FOR LOCATION

BACKER ROD & SEALANT

1/2"

BACKER ROD & SEALANT

3/4" BB PLY PANEL

1/2" REVEAL PANEL

MTL STD FRAMING

(E) WALL

CHAIR RAIL BEYOND, SEE ELEVATION DWG

1/2" BB PLY

1 5/8" MTL STD FRAMING

3/4" BB PLY

(E) WALL

WHITE BOARDINSTALL PER MANF RECOMMENDATION.SEE ELEVATION FOR PANEL LAYOUT

1 1/2"

1/2"

BACKER ROD & SEALANT

3/4" BB PLY PANEL

1/2" REVEAL PANEL

MTL STD FRAMING

PATCH PLASTER, SKIM COAT & PAINT

3

WINDOW UNIT

(E) BRICK

(E) LINTEL

(E) PLASTER WALL

PATCH PLASTER WHERE DAMAGED

SHIM

FIRE CAULKED JOINT

3 1/

8"

3 9/16"

REV. DESCRIPTION DATE

REVIEWED BY:DRAWN BY:

SHEET

DATE

SHEET TITLE

MO

NT

AN

AST

AT

E U

NIV

ER

SIT

Y

MSU-CPDCMONTANA STATE UNIVERSITY

BOZEMAN, MONTANAPHONE: 406.994.5413

FAX: 406.994.5665

428

N. L

ast C

hanc

e G

ulch

Hel

ena,

Mon

tana

5960

140

6.44

9.20

13ph

one

ww

w.m

osai

carc

h.co

m

a r c

h i

t e c

t u

r e -

p l a

n n

i n

g -

d e

s i g

n

MSU

CL

ASS

RO

OM

RE

NO

VA

TIO

NS

2019

REI

D H

ALL

40

1,4

02

-1

00

% C

D S

ET

MOSAICMOSAIC

DETAILS - REID401,402

A40001/23/2019

RE

ID H

AL

L R

OO

MS

401

& 4

02

PPA#18-2170

1" = 1'-0" REF: 1/ A100

VERT CHASE PLAN DETAIL @ WOOD WALL9 1" = 1'-0" REF: 1/ A100

WALL INFILL PLAN DETAIL @ VERT CHASE5

3" = 1'-0" REF: 1/ A100

COLUMN WRAP DETAIL83" = 1'-0" REF: 1/ A100

COLUMN WRAP DETAIL @ EXTERIOR WALL12

3" = 1'-0"INTERIOR HM DOOR FRAME HEAD1

3" = 1'-0" REF: 2/ A500

RATED INTERIOR STOREFRONT JAMB/SILL4

3" = 1'-0" REF: 4/ A300

ALTERNATE - WD WALL TO SOFFIT DETAIL13

3" = 1'-0" REF: 4/ A300

WHITE BOARD HEAD DETAIL14

3" = 1'-0" REF: 4/ A300

WHITE BOARD SILL, JAMB DETAIL15

3" = 1'-0" REF: 4/ A300

WOOD WALL BASE DETAIL16

3" = 1'-0" REF: 9/ A400

WOOD PANEL TO NEW WALL PLAN DETAIL10 3" = 1'-0" REF: 1/ A100

WOOD PANEL TO (E) WALL PLAN DETAIL6

3" = 1'-0" REF: 1/ A100

WHITEBOARD PLAN DETAIL113" = 1'-0"WOOD PANEL WALL DETAIL @ WINDOW7

3" = 1'-0" REF: 1/ A100

STOREFRONT HEAD DETAIL3

PERF METAL PANEL

SOFFIT FRAMING S.S.D.

VERTICAL REVEALS BEYOND SEE INTERIOR ELEVATIONS

CEILING TILE AND TRACK

PER RCP

RATED CLG, SEE DETAIL

FASTENER

7/8" HAT CHANNEL

ALUM SPACER

MTL TRIM PIECE

1/2"

4"

(E) STRUCTURE

PERF METAL PANEL

SOFFIT FRAMING S.S.D.

ALUM WASHER

7/8" HAT CHANNEL

PERF METAL PANEL

VERTICAL REVEALS BEYOND

FASTENER

2"

2"

1"

1"

1/2"

PER RCP

PAINT EXPOSED GWB

STOP WOOD FINISH BELOW SOFFIT

FURRED COLUMN WALL, SEE PLAN DETAIL

(E) MECH

SOFFIT FRAMING S.S.D.

7/8" HAT CHANNEL

PERF METAL PANEL

1"

REVEAL, BEYOND

RATED CEILING

(E) STRUCTURE

1/2" TYPE X GWBTO ROOFDECK

NO. 24 MSG GALVANIZED STEEL COLUMN COVER

1 5/8" MTL STD FRAMING

(E) STRUCTURAL COLUMN

PERF METAL PANEL, BEYOND

SOFFIT FRAMING S.S.D.

FASTENER

7/8" HAT CHANNEL

PERF METAL PANEL, BEYOND

3/4" BB PLY

1

(E) WINDOW MULLION

FACE OF SOFFIT (MTL PANEL) BEYOND

MTL TRIM EDGE

COLUMN FINISH, BEYOND

PERF MTL PANEL

MTL TRIM PIECE7/8" HAT CHANNEL, SEE RCP FOR LOCATION

1/2" REVEAL FINISH, BEYOND

SOFFIT FRAMING S.S.D.

ALUM WASHER

7/8" HAT CHANNEL

PERF METAL PANEL

VERTICAL REVEALS BEYOND

FASTENER

1 1/2"1/4"

3/4"

MTL PANEL MARGINNOT TO EXCEED

3/4" BB PLY

5/8" TYPE X GWB PAINTED P-1

SOFFIT FRAMING S.S.D.

FRY REGLET STEPPED OUTSIDE CORNER

5/8" TYPE X GWB PAINTED P-4

PER RCP

BASEBID: GWB SOFFIT

GWB ACCESSORIES

REVEAL: FRY REGLET STEPPED OUTSIDE CORNER

BASEBID: GWB - GYPSUM WALLBOARD SOFFIT1. CONTINUOUS GWB WITH REVEAL ON FACE2. MODIFY FRAMING DIMENSIONS TO INCORPORATE 1 3/8" GIVEN

FOR ALTERNATE METAL PANEL SOFFIT ASSEMBLY.3. 8'6" CEILING HEIGHT AS DRAWN IN RCP TO MAINTAIN IN

BASEBID.

METAL PANEL ACCESSORIES

SCREWS: #8 SELF TAPPING STAINLESS STEEL 410, PAN HEAD SCREWS

SPACERS/WASHERS: 5/16" OD ROUND SPACERS, #8X1", ALUMINUM

TRIM EDGE: ALUMINUM TYPE 402 U-EDGING (1/8" OPENING X1" WIDTH), .0630" THICK,

ALTERNATE: METAL PANEL SOFFIT

ALTERNATE: MC1 - METAL PANEL SOFFIT1. PERFORATED METAL PANELS WITH BAMBOO REVEALS2. SEE FINISH LEGEND FOR FINISHES3. ALTERNATE MC1 AS SPECIFIED IN DRAWINGS

SOFFIT FRAMING S.S.D.

CEILING TILE AND TRACK

PER RCP

RATED CLG, SEE DETAIL

(E) STRUCTURE

5/8" TYPE X GWB, PAINTED P-4

1/2" BB PLY

1 5/8" MTL STD FRAMING

CAULK

5/8" TYPE X GWB, PAINTED P-1

3/4" BB PLY

(E) WALL

SOFFIT FRAMING S.S.D.

SOFFIT PER RCP

1"

REV. DESCRIPTION DATE

REVIEWED BY:DRAWN BY:

SHEET

DATE

SHEET TITLE

MO

NT

AN

AST

AT

E U

NIV

ER

SIT

Y

MSU-CPDCMONTANA STATE UNIVERSITY

BOZEMAN, MONTANAPHONE: 406.994.5413

FAX: 406.994.5665

428

N. L

ast C

hanc

e G

ulch

Hel

ena,

Mon

tana

5960

140

6.44

9.20

13ph

one

ww

w.m

osai

carc

h.co

m

a r c

h i

t e c

t u

r e -

p l a

n n

i n

g -

d e

s i g

n

MSU

CL

ASS

RO

OM

RE

NO

VA

TIO

NS

2019

REI

D H

ALL

40

1,4

02

-1

00

% C

D S

ET

MOSAICMOSAIC

DETAILS, ALT &BASEBID - REID

401,402

A40101/23/2019

RE

ID H

AL

L R

OO

MS

401

& 4

02

PPA#18-2170

3" = 1'-0" REF: 4/ A300

ALTERNATE - METAL SOFFIT TO ACT DETAIL9

3" = 1'-0" REF: 4/ A300

ALTERNATE - METAL SOFFIT DETAIL10

3" = 1'-0" REF: 2/ A100

ALTERNATE - CEILING DETAIL @ COLUMN12

3" = 1'-0"ALTERNATE - WOOD REVEAL CORNER DETAIL @ SOFFIT11 3" = 1'-0" REF: 2/ A100

ALTERNATE - SOFFIT DETAIL @ WINDOW8

3" = 1'-0" REF: 3/ A402

ALTERNATE - BACK OF MTL PANEL DETAIL @ CENTER SOFFIT13

3" = 1'-0"ALTERNATE - WOOD REVEAL DETAIL @ SOFFIT14

3" = 1'-0"BASEBID - GWB SOFFIT DETAIL2

3" = 1'-0"BASEBID - GWB SOFFIT TO ACT DETAIL1

3" = 1'-0"BASEBID - WD WALL TO GWB SOFFIT3

3

3

2

2

1

1

A2003

2

1

4

2

A300

GG

II

KK

1

A300

EQEQ

2405 SF

CLASSROOM

401-402

401B

401A

SF1

3

A300CT-3

CT1

59'-1

0 1/

2"

CT2

CT2

PW1

P-1

P-1

PW1P-3

P-2

P-2

PW1

P-3

3 CPT SQUARES

2 CP

T SQ

UARE

S15

CPT

SQU

ARES

3 CP

T SQ

UARE

S15

CPT

SQU

ARES

3 CPT SQUARES

3

A400

CARPET PATTERN BASED ON UNCUT CARPET TILES

19 CPT SQUARES

19 CPT SQUARES

ROOM FINISH LEGENDFLOOR FINISHES:

BASE FINISHES:

PAINTED GWB: PAINT COLOR OVER GYPSUM BOARD - TYP. U.N.O.. COLOR AS INDICATED.

PAINT COLOR SELECTIONS:P1- OFF WHITE. SHERWIN WILLIAMS "CREAMY" SW-7012P2- MID GREY. SHERWIN WILLIAMS "ACIER" SW-9170P3- DARK GREY. SHERWIN WILLIAMS " ROYCROFT PEWTER" SW-2848P4 (SEE ALTERNATE)- BLUE. SHERWIN WILLIAMS "SANTORI BLUE" 7607

WALL FINISHES: CEILING FINISHES:

FLOOR FINISH NOTES:1. IF FINISHES ARE NOT CLEARLY INDICATED FOR AN AREA, CLARIFY INTENT WITH

ARCHITECT.2. PROVIDE APPROPRIATE TRANSITION TRIM AT ALL MATERIAL CHANGES.3. TEST ALL SUBSTRATES TO VERIFY COMPLIANCE WITH FINISH MANUFACTURE'S

SPECIFICATIONS PRIOR TO FLOORING INSTALLATION.4. PATCH, REPAIR, AND/OR GRIND ALL SUBSTRATES TO ACCEPTABLE LEVEL OF

SMOOTHNESS/LEVELNESS PRIOR TO FLOORING INSTALLATION.5. FLOORING CHANGE FROM ROOM TO HALLWAY TO OCCUR AT END OF VESTIBULE.6. SAMPLES FOR ALL FINISHES MUST BE SUBMITTED TO AND APPROVED BY ARCHITECT

PRIOR TO ORDERING.

SEE ROOM FINISH SCHEDULE FOR LISTING OF MATERIALS .

WALL FINISH NOTES:1. SEE INTERIOR ELEVATIONS FOR INTERIOR WINDOWS, SPECIAL WALL FINISHES, TRIM, ETC.2. IF FINISHES ARE NOT CLEARLY INDICATED FOR AN AREA, CLARIFY INTENT WITH ARCHITECT.3. PROVIDE APPROPRIATE TRANSITION TRIM AT ALL MATERIAL CHANGES.4. PROVIDE CLEAN, CONSISTENT CAULK JOINTS AT ABUTMENTS OF DISSIMILAR MATERIALS.5. PROVIDE METAL EDGING AT ALL GYPSUM BOARD EDGES THAT ABUT DISSIMILAR

MATERIALS.

ALL METAL DOORS AND DOOR FRAMES TO RECEIVE PAINT FINISH AS SPECIFIED.

COLOR SELECTIONS:INTERIOR PAINTED DOORS: WOOD TO MATCH EXISTING HALLWAY DOORSINTERIOR PAINTED DOOR FRAMES: WHITE

CORNER TRIMS:

CORNER TRIM, 26 GA. PREFIN. METAL CORNER TRIM WITH 2" WINGS.C.T.

CHAIR RAIL: CORIAN SOLID SURFACE - TYP. U.N.O. COLOR AS INDICATED.

CORIAN COLOR SELECTIONS:CR1 - ANTHRACITE

CHAIR RAIL NOTES:1. FIELD LAYOUT ALL CHAIR RAIL LENGTHS2. CHAIR RAIL TO WRAP COLUMNS AS SHOWN IN INTERIOR ELEVATIONS.

CHAIR RAIL:

GYPSUM CEILING: RATED CEILING ASSEMBLY SEE DETAILSCARPET TILE- CT1: 50CM X 50CM CARPET TILE. INSTALLATION METHOD: NON DIRECTIONAL

CARPET: INTERFACE "EXPOSED"STYLE: 1383202500 - COLOR: 106058 PRINCIPAL

RB: BLACK BROWN COLOR, 3.2 MM THICK, 4" HIGH

TRANSITION STRIP: SOLID VINYL REDUCER STRIP; GRAPHITE GRAY COLOR.

METAL PANEL CEILINGS: METAL PERFORATED CEILING/SOFFIT PANELS

ALUMN PANELS PERFORATED SIZE 3/32" ROUND ON 5/32" STAGGERED CENTERS, .080" THICK (12 GAUGE). MILL FINISH.

CARPET TILE- CT2: 50CM X 50CM CARPET TILE. INSTALLATION METHOD: NON DIRECTIONAL

CARPET: INTERFACE "CUBIC"STYLE: 1380102500 - COLOR: 106070 PRINCIPAL

CARPET TILE- CT3: 50CM X 50CM CARPET TILE. INSTALLATION METHOD: NON DIRECTIONAL

CARPET: INTERFACE "PROFILE"STYLE: 1381102500 - COLOR: 106082 PRINCIPAL

ACT1 ACOUSTIC CEILING TILE: 24" X 24" ACOUSTIC CEILING TILES -WHITE, SEE SPECS

GRID TYPE: PRELUDE XL 15/16" GRID - WHITEEDGE MOLDING: SQUARE

WD1: PLYBOO STRIPS, 3/4" THICK, 4" HIGH

BAMBOO PLYWOOD PANELING: 3/4" THICK FLAT GRAIN 3PLY WITH, 1 1/2" REVEALS, 1/2" BATTENS - TYP. U.N.O.. COLOR AS INDICATED.

PANEL STAIN SELECTIONS:PW1- AMBERBATTEN STAIN SELECTIONS:PW2- FOG STAINED

DOOR & DOOR FRAME FINISHES:

6'-0"

1'-8"

2'-3

1/8

"8 1

/8"

3'-1

0 1/

4"

STORE FRONT TYPESSEE PLAN FOR LOCATIONS

A400

4

Sim

A400

3

Sim

SF1

1. ALL DOOR LOCATIONS NOT SPECIFICALLY DIMENSIONED TO BE PLACED 4 INCHES FROM ADJACENT WALL SURFACE. IF THERE IS NO DIRECTLY ADJACENT SIDEWALL, CONTACT ARCHITECT FOR PROPER PLACEMENT.

2. ALL DOORS TO HAVE ADA COMPLIANT THRESHOLDS WITH 1/2" MAXIMUM RISE UNLESS SPECIFICALLY DETAILED OTHERWISE.

3. ALL METAL DOORS AND FRAMES TO BE PRIMED AND PAINTED. VERIFY COLOR WITH ARCHITECT.

4. ALL HARDWARE ON FIRE-RATED DOORS MUST BE APPROVED FOR SUCH USE AND INSTALLED AS REQUIRED TO MAINTAIN SYSTEM FIRE RATING.

5. ALL DOORS/FRAMES TO HAVE RESILIENT SILENCERS.6. CONTRACTOR TO USE ARCHITECT'S DOOR TYPE PLAN DESIGNATION

NUMBER IN ADDITION TO THE ROOM NUMBER ON ALL SHOP DRAWING SUBMITTALS

7. FIRE RATING FOR FRAMES MUST MATCH RATING FOR DOORS.8. SEE WINDOW ELEVATIONS FOR FRAME TYPES FOR ALUMINUM

FRAMES.9. ALL EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS

SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT.

10. DOOR THICKNESS SHALL BE 1 3/4" TYP UNLESS NOTED OTHERWISE.

GENERAL DOOR NOTESALUMANODSPECFACTHMSFWD

ABBREVIATIONSALUMINUMANODIZED FINISH - COLOR PER SPECIFICATIONSFACTORY FINISHHOLLOW METALALUMINUM STOREFRONTWOOD - SOLID CORE

FULLY TEMPERED SAFETY GLAZING

GLAZING LEGEND

7/8" FIRE RATED 60 MIN

7/8" FIRE RATED 60 MIN WITH "FROSTED" FILM

DOOR TYPES

DOUBLE VGDOUBLE VISION GLASS DOOR

SEE PLAN AND SCHEDULE FOR ALL DOOR SIZES

VGVISION GLASS DOOR

FF

H.M. FRAME

2"SCHEDULE

PER 2"

PER

SCHE

DULE

2"

DOOR FRAME TYPESSEE PLAN AND SCHEDULE FOR ALL DOOR SIZES

A

HM FRAME FOR DOUBLE DOORS

2"SCHEDULE

PER 2"

PER

SCHE

DULE

2"

B

INTR

INTR

EXTR

1

A400Sim

1

A400Sim

1. ALL PAINTING, WALLCOVERING AND GYPSUM WALLBOARD FINISHING PER "ARCHITECTURAL SPECIFICATION MANUAL" PAINTING AND DECORATING CONTRACTORS OF AMERICA.

2. PROVIDE SAMPLES OF SPECIFIED FINISHES TO ARCHITECT FOR APPROVAL PRIOR TO APPLICATION3. PROVIDE TO OWNER APPROXIMATELY 5% OF ADDITIONAL FINISH MATERIAL FOR FUTURE REPAIR

AND MAINTENANCE. (IE. - PAINT, VINYL FLOORING, RUBBER BASE, ETC.)

GENERAL FINISH NOTES:

1. IF FINISHES ARE NOT CLEARLY INDICATED FOR AN AREA, CLARIFY INTENT WITH ARCHITECT.2. PROVIDE APPROPRIATE TRANSITION TRIM AT ALL MATERIAL CHANGES.3. PROVIDE EXTRUDED ALUMINUM EDGE METAL AT TERMINATION OF ALL CERAMIC TILE AREAS.4. TEST ALL SUBSTRATES TO VERIFY COMPLIANCE WITH FINISH MANUFACTURE'S SPECIFICATIONS

PRIOR TO FLOORING INSTALLATION.5. PATCH, REPAIR, AND/OR GRIND ALL SUBSTRATES TO ACCEPTABLE LEVEL OF

SMOOTHNESS/LEVELNESS PRIOR TO FLOORING INSTALLATION.6. FLOORING CHANGES FROM ROOM TO ROOM TO OCCUR DIRECTLY UNDER THE DOOR LOCATION.7. SAMPLES FOR ALL FINISHES MUST BE SUBMITTED TO AND APPROVED BY ARCHITECT PRIOR TO

ORDERING.

FLOOR FINISH NOTES:

1. IF FINISHES ARE NOT CLEARLY INDICATED FOR AN AREA, CLARIFY INTENT WITH ARCHITECT.2. PROVIDE APPROPRIATE TRANSITION TRIM AT ALL MATERIAL CHANGES.3. PROVIDE CLEAN, CONSISTENT CAULK JOINTS AT ABUTMENTS OF DISSIMILAR MATERIALS.4. PROVIDE METAL EDGING AT ALL GYPSUM BOARD EDGES THAT ABUT DISSIMILAR MATERIALS.5. PROVIDE EXTRUDED ALUMINUM EDGE METAL AT ALL EXPOSED TILE EDGES.

WALL FINISH NOTES:

1. IF FINISHES ARE NOT CLEARLY INDICATED FOR AN AREA, CLARIFY INTENT WITH ARCHITECT.2. PROVIDE APPROPRIATE TRANSITION TRIM AT ALL MATERIAL CHANGES.3. PROVIDE CLEAN, CONSISTENT CAULK JOINTS AT ABUTMENTS OF DISSIMILAR MATERIALS.4. PROVIDE DIAGONAL AND VERTICAL SEISMIC BRACING AT ALL SUSPENDED CEILING SYSTEMS IN

COMPLIANCE WITH CURRENT BUILDING CODES.5. PROVIDE 2 INCH EDGE METAL AT ALL LAY-IN SUSPENDED CEILING SYSTEMS OR OTHER CODE

APPROVED SEISMIC RETENTION SYSTEM.6. WHERE PAINTED, EXPOSED CEILING IS INDICATED, ALL COMPONENTS TO BE PAINTED UNLESS

SPECIFICALLY NOTED OTHERWISE. THIS INCLUDES PAINTING DECK, STRUCTURAL FRAMING, BRACING, MECHANICAL EQUIPMENT, SPRINKLER PIPING, NON-GALVANIZED ELECTRICAL CONDUIT, NON-GALVANIZED PIPING.

CEILING FINISH NOTES: REV. DESCRIPTION DATE

REVIEWED BY:DRAWN BY:

SHEET

DATE

SHEET TITLE

MO

NT

AN

AST

AT

E U

NIV

ER

SIT

Y

MSU-CPDCMONTANA STATE UNIVERSITY

BOZEMAN, MONTANAPHONE: 406.994.5413

FAX: 406.994.5665

428

N. L

ast C

hanc

e G

ulch

Hel

ena,

Mon

tana

5960

140

6.44

9.20

13ph

one

ww

w.m

osai

carc

h.co

m

a r c

h i

t e c

t u

r e -

p l a

n n

i n

g -

d e

s i g

n

MSU

CL

ASS

RO

OM

RE

NO

VA

TIO

NS

2019

REI

D H

ALL

40

1,4

02

-1

00

% C

D S

ET

MOSAICMOSAIC

SCHEDULES, FINISHPLAN - REID 401,402

A50001/23/2019

RE

ID H

AL

L R

OO

MS

401

& 4

02

PPA#18-2170

1/4" = 1'-0" REF: 1/ A300

LEVEL 4 - FINISH PLAN1

DOOR SCHEDULE

MARK DOOR TYPE DESCRIPTION HEIG

HT

WID

TH

THIC

KNES

S

HARDWAREGROUP

FRAMETYPE

FRAMEMATERIAL

FIRERATING COMMENTS

401A DF HM DOUBLE VG DOOR 7'-0" 6'-0" HM ALUM401B DF HM DOUBLE VG DOOR 7'-0" 6'-0" HM ALUM

ROOM 401-402 FINISH SCHEDULENO. Name Area Perimeter Floor Finish Base Finish North Wall East Wall South Wall West Wall Ceiling Finish Comments

401-402 CLASSROOM 2405 SF 207'-2" CT1 / CT2/ CT3 RB1 / WB1 PW1 P1 PW1 P2/P3 AT1 / MP1 SEE PLANS AND ELEVATIONS FOR ADDITIONAL INFORMATION

2405 SF

CLASSROOM

401-402

1'-0"

9'-7

"

5'-2

1/2

"

2'-0"

5'-1

"

8'-0"

8'-0"

1'-0"

1'-7"2'-0"2'-0"2'-0"

7'-3

1/2

"3'

-6"

3'-6

"

2405 SF

CLASSROOM

401-402

2405 SF

CLASSROOM

401-402

REV. DESCRIPTION DATE

REVIEWED BY:DRAWN BY:

SHEET

DATE

SHEET TITLE

MO

NT

AN

AST

AT

E U

NIV

ER

SIT

Y

MSU-CPDCMONTANA STATE UNIVERSITY

BOZEMAN, MONTANAPHONE: 406.994.5413

FAX: 406.994.5665

428

N. L

ast C

hanc

e G

ulch

Hel

ena,

Mon

tana

5960

140

6.44

9.20

13ph

one

ww

w.m

osai

carc

h.co

m

a r c

h i

t e c

t u

r e -

p l a

n n

i n

g -

d e

s i g

n

MSU

CL

ASS

RO

OM

RE

NO

VA

TIO

NS

2019

REI

D H

ALL

40

1,4

02

-1

00

% C

D S

ET

MOSAICMOSAIC

FURNITURE PLANS -REID 401, 402

A70001/23/2019

RE

ID H

AL

L R

OO

MS

401

& 4

02

PPA#18-2170

1/4" = 1'-0" REF: 1/ A300

LEVEL 4 - REID - 401-402 FURNITURE OPT 1 - lecture layout1

REID 401-402 OPTION 1 FURNITURE SCHEDULESAMPLEIMAGE RM

TYPEMARK MODEL TYPE

GENERALDESCRIPTION QTY MANUF. COMMENTS

401-402401-402 Chair_loose_KI-Learn2-IntellectWave 3 SINGLE CHAIR W/ CASTERS 29 KI, Inc. STUDENT FURNITURE N.I.C. FOR REFERENCE ONLY

401-402 Chair_loose_KI-Learn2-IntellectWave 4 SINGLE CHAIR W/ CASTERS 26 KI, Inc. STUDENT FURNITURE N.I.C. FOR REFERENCE ONLY

401-402 CH-1 Chair_loose_KI-Learn2-IntellectWave SINGLE CHAIR W/ CASTERS 25 KI, Inc. STUDENT FURNITURE N.I.C. FOR REFERENCE ONLY

401-402 CH-2 ADJ TABLET CHAIR_CASTERS MOVABLE CHAIR WITHADJUSTABLE TABLET

40 KI, Inc. STUDENT FURNITURE N.I.C. FOR REFERENCE ONLY

401-402 L1 LECTERN_DRAFTED 1 LECTERN N.I.C. FOR REFERENCE ONLY

401-402 T-1 Table_loose_Rectangular5' Pirouette Table 40 KI STUDENT FURNITURE N.I.C. FOR REFERENCE ONLY

401-402 WB1 8' MARKER BOARD MARKER BOARD 9

401-402 WB2 10' WHITE BOARD MARKER BOARD 4

Grand total: 174

1/8" = 1'-0" REF: 1/ A300

LEVEL 4 - REID - 401-402 FURNITURE OPT 1 - active learning layout 12 1/8" = 1'-0" REF: 1/ A300

LEVEL 4 - REID - 401-402 FURNITURE OPT 1 - active learning layout 23

XOS OS

P

R1

R2

R3

R4

LVD

M

M

M

SPD

LA

PFC

M

VFD

G

CB

PNL A208Y/120V

3ø, 4W

XX

X

J

TV

J

PS-X

X

D-1X

H

SD

DSD

SS

CO

D

F

FF

SS

WA

ELECTRICAL ABBREVIATIONS LEGENDA, AMP AMPERESAC ALTERNATING CURRENTA/C AIR CONDITIONINGAF AMP FUSEAFF ABOVE FINISHED FLOORAFG ABOVE FINISHED GRADEAHU AIR HANDLING UNITAL ALUMINUMAS AMP SWITCHATS AUTOMATIC TRANSFER SWITCHBAS BUILDING AUTOMATION SYSTEMBKR BREAKERC RACEWAY/CONDUITCB CIRCUIT BREAKERCCTV CLOSED CIRCUIT TELEVISIONCKT CIRCUITCLG CEILINGC.O. RACEWAY/CONDUIT ONLY, WITH PULL STRINGCNTRL CONTROLCU COPPERD EXISTING TO BE DEMOLISHEDDISC DISCONNECTDIST DISTRIBUTIONDPDT DOUBLE POLE DOUBLE THROWDWG DRAWINGEA EACHEF EXHAUST FANELEC ELECTRICEMT ELECTRICAL METALLIC TUBINGEQUIP EQUIPMENTEX, EXIST EXISTINGFA FIRE ALARMFAA FIRE ALARM ANNUNCIATORFACP FIRE ALARM CONTROL PANELFD FUSED DISCONNECTFLR FLOORFO FIBER OPTICFSD FIRE SMOKE DAMPER RELAY, CONTROLLED BY

ASSOCIATED SMOKE DETECTOR AND CIRCUITED BACK TO FACP

FVNR FULL VOLTAGE NON-REVERSINGFVR FULL VOLTAGE REVERSINGGEC GROUNDED ELECTRODE CONDUCTORGFCI GROUND FAULT CIRCUIT INTERRUPERGFI GROUND FAULT INTERRUPTERGFP GROUND FAULT PROTECTIONGND GROUNDGRC GALVANIZED RIGID CONDUITHID HIGH INTENSITY DISCHARGEHOA HAND-OFF-AUTOMATICHP HORSEPOWERHPS HIGH PRESSURE SODIUMHTR HEATERHVAC HEATING, VENTILATION & AIR CONDITIONINGHZ HERTZJ-BOX JUNCTION BOXKVA KILOVOLT-AMPERESKW KILOWATTSLCP LIGHTING CONTROL PANELLPW LUMENS PER WATTLTG LIGHTINGLV LOW VOLTAGEMAG MAGNETIC STARTER

MAN MANUALMAX MAXIMUMMCA MINIMUM CIRCUIT AMPACITYMCC MOTOR CONTROL CENTERMDP MAIN DISTRIBUTION PANELMECH MECHANICALMH METAL HALIDEMIN MINIMUMMSS MOTOR STARTER SWITCH WITH THERMAL OVERLOADSN NEUTRALNC NORMALLY CLOSEDNEC NATIONAL ELECTRIC CODENEMA NATIONAL ELECTRICAL MANUFACTURERS

ASSOCIATIONNFD NON-FUSED DISCONNECTNIC NOT IN CONTRACTNO NORMALLY OPEN# NUMBEROAE OR APPROVED EQUALOC ON CENTEROCPD OVERCURRENT PROTECTIVE DEVICEOH OVERHEADP POLEPB PUSHBUTTONPH PHASEPNL PANELPOE POWER OVER ETHERNETPVC POLYVINYL CHLORIDE CONDUITPWR POWERR EXISTING TO REMAINRCPT RECEPTACLERECEPT RECEPTACLERGS RIGID GALVANIZED STEELRM ROOMRVNR REDUCED VOLTAGE NON-REVERSINGRVR REDUCED VOLTAGE REVERSINGSP SINGLE POLE TOGGLE SWITCHSPD SURGE PROTECTIVE DEVICE (TVSS)SPEC SPECIFICATIONSPST SINGLE POLE SINGLE THROWSSPB START-STOP PUSHBUTTONSW SWITCHSWBD SWITCHBOARDSWGR SWITCHGEARTB TELEPHONE BOARDTC TIME CLOCKTD TIME DELAYTEL TELEPHONETSP TWISTED SHIELDED PAIRTTB TELEPHONE TERMINAL BOARDTYP TYPICALUG UNDERGROUNDUH UNIT HEATERUNO UNLESS NOTED OTHERWISEV VOLTVA VOLT-AMPERESVFD VARIABLE FREQUENCY DRIVEW WATTSWP WEATHERPROOFW/O WITHOUTXFMR TRANSFORMERY WYE-CONNECTEDΔ DELTA-CONNECTEDø PHASE

ELECTRICAL LIGHTING FIXTURE LEGENDRECESSED LED FIXTURE - "a" & "b" DESIGNATES SWITCH

EXIT SIGN - WALL MOUNT, CEILING MOUNT. ARROW INDICATES DIRECTION OF TRAVEL, SHADING INDICATES LIGHTED FACE.

RECESSED EMERGENCY LED FIXTURE - "a" & "b" DESIGNATES SWITCH

SURFACE LED FIXTURE - "a" & "b" DESIGNATES SWITCH

SURFACE EMERGENCY LED FIXTURE - "a" & "b" DESIGNATES SWITCH

SURFACE WALL MOUNT LED FIXTURE

LED STRIP OR INDUSTRIAL, SURFACE OR CHAIN HUNG

EMERGENCY LED STRIP OR INDUSTRIAL, SURFACE OR CHAIN HUNG

POLE MOUNTED FIXTURE

LIGHTED BOLLARD

PENDANT FIXTURE; HIGH BAY, LOW BAY, DECORATIVE

DUAL HEAD EMERGENCY EGRESS BATTERY PACK, WALL MOUNT OR CEILING MOUNT

WALL MOUNTED SCONCE

SURFACE DOWNLIGHT

SURFACE EMERGENCY DOWNLIGHT

RECESSED CAN DOWNLIGHT

RECESSED CAN EMERGENCY DOWNLIGHT

RECESSED CAN WALL WASHER

TRACK LIGHTING. SEE FIXTURE SCHEDULE AND LIGHTING PLANS.

ELECTRICAL LIGHTING CONTROL LEGEND

TOGGLE SWITCH (MOUNT AT +46", UNO)"X" INDICATES TYPE:

BLANK - SINGLE POLE3 - INDICATES THREE-WAY4 - INDICATES FOUR-WAYD - INDICATES DIMMER SWITCH

PHILIPS SUNRISE - ON/OFFK - INDICATES KEYED SWITCH (MOUNT AT +52")T - INDICATES TIMERP - INDICATES PILOT LIGHTOS - INDICATES WALL SWITCH OCC SENSOR

WATTSTOPPER DW100 (SINGLE OR DUAL DW-200 SWITCH)

OSD - INDICATES WALL SWITCH OCC SENSOR WITH 0-10V DIMMING - WATTSTOPPER W-311

a - INDICATES SINGLE POLE LIGHTING SWITCH ZONE FOR ZONE a

b - INDICATES SINGLE POLE LIGHTING SIWTCH ZONE FOR ZONE b

ab - INDICATES LIGHTING SWITCHES WITH MULTIPLE ZONES

OCCUPANCY SENSOR - CEILING MOUNT, WALL MOUNTWATTSTOPPER LMDC-100, OR EQUAL

PHOTOCELL - CEILING MOUNTWATTSTOPPER LMLS-400, OR EQUAL

STANDARD LIGHTING CONTROLS:SWITCHES AND LINE VOLTAGE DIMMERS

DIGITAL LIGHTING CONTROLS:ROOM CONTROLLERS AND LOW VOLTAGE DEVICES

ON/OFF ROOM CONTROLLER WITH (1) RELAYWATTSTOPPER DLM LMRC-101, OR EQUAL

ON/OFF ROOM CONTROLLER WITH (2) RELAYSWATTSTOPPER DLM LMRC-102, OR EQUAL

ON/OFF/0-10V ROOM CONTROLLER WITH (2) RELAYSWATTSTOPPER DLM LMRC-212, OR EQUAL

ON/OFF/0-10V ROOM CONTROLLER WITH (3) RELAYSWATTSTOPPER DLM LMRC-213, OR EQUAL

LOW VOLTAGE DIMMING SWITCHWATTSTOPPER DLM LMDM-101, OR EQUAL

(MOUNT AT 46" AFF)

ELECTRICAL ONE-LINE LEGEND

MOTOR SYMBOL

CT AND CUSTOMER POWER METER

UTILITY ELECTRIC METER AND BASE (BASE BY CUSTOMER)

SURGE PROTECTION DEVICE

LIGHTNING ARRESTOR

STRESS RELIEF CONE

POWER FACTOR CORRECTION CAPACITOR

MOTOR STARTER SWITCH W/ THERMAL OVERLOADS

CONTACTOR NORMALLY OPEN, NORMALLY CLOSED

TRANSFORMER, 3-PH, 3-WIRE DELTA CONNECTION

TRANSFORMER, 3-PH, 4-WIRE GROUNDED WYE CONNECTION

AUTOMATIC TRANSFER SWITCH

VARIABLE FREQUENCY DRIVE

FIXED MOUNT LV BREAKER

FUSED SWITCH ("XXAS/XXAF" - SW AND FUSE AMP RATING)

GENERATOR

WALL MOUNTED BREAKER

THERMAL OVERLOAD ELEMENT

DISCONNECT SWITCH ("XXAS" = SWITCH AMP RATING)

FUSED DISCONNECT SWITCH ("XXAS/XXAF" = SW AND FUSE AMP RATING)

COMBINATION MOTOR STARTER (STR SIZE, TYP, AS, AF, SEE MEP COORDINATION SCHEDULE)

SWITCHBOARD OR PANELBOARD; NAME, VOLTAGE, PHASE, NUMBER OF WIRES WHEN INDICATED

ELECTRICAL POWER LEGEND

PANEL AND CIRCUIT DESIGNATION ARE SHOWN NEXT TO EACH DEVICE (PANEL NAME - CIRCUIT NUMBER). BRANCH CIRCUIT WIRE SIZE IS #1, UNO. A SINGLE INSULATED GREEN GROUND CONDUCTOR SHALL BE PROVIDED WITH EACH HOME RUN. PROVIDE A SEPARATE NEUTRAL FOR EACH CIRCUIT. HOME RUNS SHALL HAVE NO MORE THAN THREE CIRCUITS. LINE VOLTAGE AND LOW VOLTAGE WIRING IS NOT SHOWN ON PLANS. FOR EQUIPMENT CIRCUITING, SEE MEP COORDINATION SCHEDULE."X" INDICATES TYPE:

GFI - GROUND FAULT INTERRUPTERWP - WEATHERPROOF WHILE-IN-USE COVERU - PROVIDE WITH (2) USB PORTS

PANELBOARD OR LOAD CENTER

JUNCTION BOX

FLATSCREEN TV BOX: 2-GANG, FLUSH IN WALL, HUBBELL RACO NSAV62M, WITH NSAV6C COVER. DUPLEX RECEPTACLE & SINGLE GANG DATA PORT. MOUNT AT +72", UNO.

SIMPLEX RECEPTACLE - CEILING MOUNT, WALL MOUNT (+18", UNO)

DUPLEX RECEPTACLE - CEILING MOUNT, WALL MOUNT (+18", UNO)

QUADRUPLEX RECEPTACLE - CEILING MOUNT, WALL MOUNT (+18", UNO)

FLOOR BOX WITH RECEPTACLE - INCLUDE ALL HARDWARE AND ACCESSORIES REQUIRED.

SPECIAL PURPOSE RECEPTACLE (MOUNT AT +18", UNO)"X" INDICATES TYPE:

A - NEMA 5-20R, #12 CU; B - NEMA 5-30R, #10 CU;C - NEMA 5-50R, #8 CU; D - NEMA 6-20R, #12 CU;E - NEMA 6-30R, #10 CU; F - NEMA 6-50R, #8 CU;G - NEMA 14-20R, #12 CU; H - NEMA 14-30R, #10 CU;I - NEMA 14-50R, #8 CU

DROP-DOWN RECEPTACLE

SURFACE MOUNTED PLUGSTRIP"X" INDICATES TYPE:

A - PLUGSTRIP, POWER ONLY, OUTLET EVERY 3' OCB - WIREMOLD SERIES 4000 POWER AND DATAC - WIREMOLD SERIES 5000 POWER AND DATA

SURFACE MOUNTED RACEWAY

RACEWAY CONCEALED IN WALL, FLOOR, OR CEILING IN FINISHED SPACES, EXPOSED IN UNFINISHED SPACES

RACEWAY BELOW FLOOR OR BELOW GRADE

RACEWAY STUB-OUT WITH CAPPED END

RACEWAY STUB-OUT WITH BRUSHED END

GROUNDING BUS

PUSHBUTTON (MOUNT AT +46", UNO)"X" INDICATES TYPE:

EPO - EMERGENCY POWER OFFADA - HANDICAPPED ACCESSIBLE DOOR

(DEVICE BY OTHERS)ODO - OVERHEAD DOOR OPERATOR

(DEVICE BY OTHERS)

FIRE RATED POKE-THROUGH FLOOR BOX FOR ELEVATED CONCRETE SLABS, UP TO 2" CONDUIT FEED (HUBBELL NO. PT7FSDIA WITH FRFIA COVER , OAE)

ABOVE COUNTER RECEPTACLE - MOUNT AT+4" ABOVE BACKSPLASH

ELECTRICAL LOW VOLTAGE LEGENDFIRE ALARM SYSTEM / TELEPHONE/DATA SYSTEM

HEAT DETECTOR

SMOKE DETECTOR - PHOTO-ELECTRIC

DUCT SMOKE DETECTOR

SINGLE-STATION SMOKE DETECTOR. PROVIDE 120V AND MONITOR AT FACP VIA RELAY.

CARBON MONOXIDE DETECTOR

DOOR HOLDER

MANUAL STATION (MOUNT AT +46", UNO)

STROBE - WALL MOUNT (+90"), CEILING MOUNT

HORN/STROBE - WALL MOUNT (+90"), CEILING MOUNT

SPEAKER STROBE - WALL MOUNT (+90"), CEILING MOUNT

TELEPHONE OUTLET. SEE NOTE.

VOICE-DATA OUTLET. SEE NOTE.

DATA OUTLET. SEE NOTE.

WIRELESS ACCESS POINT

CABLE TRAY OR BASKET TRAY - LENGTH AND HEIGHT PER PLAN

NOTE: PROVIDE ROUGH-IN ONLY. SINGLE GANG WIREMOLD BOX & 700 SERIES WIREMOLD STUBBED UP TO ACCESSIBLE CEILING SPACE. COORDINATE WITH MSU IT.

ELECTRICAL PROJECT NOTESA. PRIOR TO BID CONTRACTOR SHALL VISIT THE SITE. NOT ALL WORK REQUIRED TO COMPLETE THE PROJECT IS SHOWN ON THE DRAWINGS.

THE CONTRACTOR SHALL BECOME THOROUGHLY FAMILIAR WITH ALL THE WORK REQUIRED TO COMPLETE THE PROJECT IN ADDITION TO THE LOCAL CONDITIONS AND INCLUDE SAID WORK IN THE BID.

B. GENERAL WORK PRACTICES FOR ELECTRICAL CONSTRUCTION SHALL BE IN ACCORDANCE WITH NECA 1, "STANDARD PRACTICES FOR GOOD WORKMANSHIP IN ELECTRICAL CONTRACTING." THIS PUBLICATION IS AVAILABLE FROM NECA BY TELEPHONE AT 301-657-3110 OR ON-LINE AT WWW.NECANET.ORG.

C. DURING DEMOLITION, THE CONTRACTOR SHALL NOTE ALL EXISTING RACEWAY (BOTH SURFACE AND CONCEALED) TO THE EXTENT POSSIBLE. THESE RACEWAYS SHALL BE REUSED TO THE GREATEST EXTENT POSSIBLE TO INSURE A CLEAN FINISHED PRODUCT. WHERE PRACTICAL, AND ALLOWED PER CODE, FISHING THROUGH WALLS WITH MC CABLE IS PREFERRED TO SURFACE-MOUNTED CONDUIT.

D. CONTRACTOR SHALL REMOVE, TRANSPORT, AND LEGALLY DISPOSE OF LAMPS AND BALLASTS OFF-SITE. IT IS ASSUMED THE THE BALLASTS DO NOT CONTAIN PCBs. THE CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY IF IT IS SUSPECTED THAT BALLASTS CONTAIN PCBs.

E. ALL POWER INTERRUPTIONS SHALL BE COORDINATED WITH OWNER. ANY DISRUPTION OF WORKERS IN THE SPACE SHALL BE KEPT TO A MINIMUM AND BE COORDINATED WITH THE OWNER PRIOR TO WORK COMMENCING IN THAT SPACE.

F. CONTRACTOR SHALL EXTEND UNSWITCHED HOT LEG FROM EXISTING EMERGENCY FIXTURE LOCATION TO NEW EMERGENCY FIXTURES. AS NEEDED. SEE DEMO PLANS FOR AN APPROXIMATION OF EXISTING EMERGENCY FIXTURE LOCATIONS. FIELD VERIFY EXACT LOCATION PRIOR TO BID.

G. IT IS THE CONTRACTORS RESPONSIBILITY TO COORDINATE WITH MECHANICAL FOR PLENUM SPACES AND PROVIDE PLENUM RATED CABLES WHERE REQUIRED FOR LIGHTING CONTROL, DATA, FIRE ALARM AND ALL OTHER L.V. SYSTEMS NOT INSTALLED IN CONDUIT. VERIFY CONDUIT REQUIREMENTS ON DRAWINGS AND SPECIFICATIONS.

H. FIRE-RESISTANCE: PROVIDE A MINIMUM HORIZONTAL DISTANCE OF 24" BETWEEN OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE-RESISTANCE RATED WALLS. WHERE THIS IS NOT POSSIBLE INSTALL UL LISTED PUTTY PADS ON ALL OUTLET BOXES NOT MEETING THE 24" SEPARATION. PROVIDE A UL LISTED THROUGH -PENETRATION FIRESTOP FOR PENETRATIONS OF FIRE-RESISTANCE RATED ASSEMBLIES.

I. CONDUCTORS ARE SIZED PER THE 75 DEGREE C RATING COLUMN OF NEC TABLE 310.16. IF THE TERMINAL USED FOR A TERMINATION OF A PARTICULAR CONDUCTOR IS NOT MARKED, OR THE TERMINAL IS MARKED FOR 60 DEGREE C CONDUCTORS, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO EITHER ADJUST THE AMPACITY OF THE CONDUCTOR TO MATCH THE 60 DEGREE COLUMN OF TABLE 310.16, OR REPLACE THE TERMINAL WITH ONE RATED FOR AT LEAST 75 DEGREES C.

J. BASED ON ACTUAL HOMERUN LENGTHS REQUIRED IN THE FIELD, THE CONTRACTOR SHALL CALCULATE AND INCREASE THE WIRE SIZES AS REQUIRED TO LIMIT BRANCH CIRCUIT VOLTAGE DROP TO 3%. FOR 20A BRANCH CIRCUITS THE MINIMUM CONDUCTOR SIZES SHALL BE AS FOLLOWS: #10 AMG CU FOR RUNS BETWEEN 100 AND 200 LINEAR FEET, #8 AWG CU FOR RUNS BETWEEN 200 AND 325 LINEAR FEET, ANS AS CALCULATED BY THE CONTRACTOR FOR CIRCUITS EXTENDING BEYOND 325 LINEAR FEET. IN ALL CASES WHERE WIRE SIZES INCREASE, THE CONTRACTOR SHALL PROVIDE LARGER CONDUITS AS REQUIRED.

K. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH 120V BRANCH CIRCUIT.L. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR OF ANY EXISTING CIRCUITS THAT ARE INTENDED TO REMAIN THAT ARE SAW

CUT OR INTERRUPTED AS PART OF THE DEMOLITION PROCESS. PROVISION FOR THIS WORK SHALL BE INCLUDED IN THE BID. SUCH CIRCUITS INCLUDE BUT ARE NOT LIMITED TO: INTERIOR RECEPTACLE CIRCUITS, INTERIOR LIGHTING CIRCUITS, EXTERIOR BUILDING LIGHTING, SITE LIGHTING, ETC.

M. ELECTRICAL DRAWINGS SHOWING EXISTING BUILDING CONDITIONS, SUCH AS DEMOLITION DRAWINGS, EXISTING PANEL SCHEDULES, ETC ARE BASED ON RECORD DRAWINGS AND SITE VISITS. IF ACTUAL EXISTING CONDITIONS DIFFER FROM THOSE SHOWN ON DRAWINGS, PLEASE NOTIFY ENGINEER.

ABBREVIATIONS AND SYMBOLS GENERAL NOTESA. THE ABBREVIATIONS ON THIS SHEET COMPRISE A STANDARD LIST; NOT ALL ABBREVIATIONS APPEAR ON THIS PROJECT.B. THE SYMBOLS ON THIS SHEET COMPRISE A STANDARD LIST; NOT ALL SYMBOLS APPEAR ON THIS PROJECT.C. ALL MOUNTING HEIGHTS ARE TO CENTER OF DEVICE ABOVE FINISHED FLOOR, UNLESS NOTED OTHERWISE. MOUNTING HEIGHTS INDICATED

ON ARCHITECTURAL WALL ELEVATIONS OR AS NOTED SPECIFICALLY ON THE DRAWINGS OR IN THE SPECIFICATIONS SHALL TAKE PRECEDENCE OVER MOUNTING HEIGHTS LISTED.

Red

NEUTRAL WHTYel

Blu

Vio

Gry

VioGry

VioGry

VioGry

Vio

Gry V

ioG

ry

CLASS 2 0-10 VOLTCONTROL WIRING

0-10VDC DIMMINGBALLAST REQUIRED.

RJ45 PORT(TYPICAL)

LMRJ SERIES PRE-TERMINATED CABLES OR CAT5E.FREE TOPOLOGY & SPLITTER ACCEPTABLE

UNSWITCHEDHOT BLK120/277

LMRC-213 TRIPLE RELAY ON/OFF/0-10VDIMMING ROOM CONTROLLER

(5) LMDM-101 DIGITALDIMMING SWITCHES (TYP. (3) LOCATIONS)

RJ45(TYP.)

LMRJ-C8COUPLER

LMDC-100OCCUPANCY

SENSOR

LMLS-400PHOTOSENSOR

LIGHTING LOAD(a)

LIGHTING LOAD (b)

LIGHTING LOAD (c)

SEQUENCE OF OPERATION:-DEVICES ARE PRESET FOR PLUG n' GO OPERATION.-ALL ROOMS ARE STAND ALONE.-NUMBER OF ZONES ("a" "b" ETC) INDICATED NUMBER OF RELAYS REQUIRED IN A ROOM.-THE ROOM CONTROLLER DEFAULTS TO MULTI-LEVEL AUTOMATIC-ON/AUTOMATIC OFF. -REUSE EXISTING LIGHTING CIRCUITS IN ROOM. RE-ROUTE LINE VOLTAGE TO ROOM CONTROLLERS AS REQUIRED. -DAYLIGHT SENSOR SHALL AUTOMATICALLY DIM LIGHTS LABELED 'b' & 'd' TO A PREDETERMINED LIGHT LEVEL. SWITCHES FOR ZONE 'b' & 'd' TO OVERRIDE DAYLIGHTING CONTROLS FOR MANUAL OPERATION.

'a' 'b'

Red VioGry

Vio

Gry

CLASS 2 0-10 VOLTCONTROL WIRING

0-10VDC DIMMINGBALLAST REQUIRED.

RJ45 PORT(TYPICAL)

UNSWITCHEDHOT BLK120/277

LMRC-213 TRIPLE RELAY ON/OFF/0-10VDIMMING ROOM CONTROLLER LIGHTING LOAD

(d)

Yel VioGry

LIGHTING LOAD(e)

Vio

Gry

'c' 'd' 'e'

No. 60006 PE

RYAN P.

MARONEY

MONTA NA

L IC ENSED

PR

OF

ESSIONA L ENGIN

EE

R

REV. DESCRIPTION DATE

REVIEWED BY:

DRAWN BY:

SHEET

DATE

SHEET TITLE

MO

NT

AN

AS

TA

TE

UN

IV

ER

SIT

Y

MSU-CPDCMONTANA STATE UNIVERSITY

BOZEMAN, MONTANA

PHONE: 406.994.5413

FAX: 406.994.5665

Consultant #:

3821-043

MS

U C

LA

SS

RO

OM

RE

NO

VA

TIO

NS

2019

RE

ID H

AL

L 4

01

, 4

02

-1

00

% C

D S

ET

RPMGLS

ELECTRICAL

SYMBOLS AND

ABBREVIATIONS

E001

01/23/2019

PPA#18-2170

RE

ID

HA

LL

RO

OM

S 4

01 &

402

1. ALTERNATE FIXTURE REQUIRES PRIOR APPROVAL.2. ACCEPTABLE ALTERNATE MANUFACTURER: AXLEN OR PHILIPS DAYBRITE.

THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING TYPES AND PROVIDE ALLREQUIRED MOUNTING ACCESSORIES. FOR FIRE-RATED CEILING ASSEMBLIES, VERIFYALL RECESSED LUMINAIRE HOUSINGS ARE FIRE-RATED OR PROVIDE FIRE-RATED,DROP-OVER ENCLOSURES OR TENT LUMINAIRE. VERIFY THAT DROP-OVER ENCLOSURESOR TENTS ALLOW FOR AIR SPACE AROUND LUMINAIRE PER MANUFACTURER'SRECOMMENDATIONS.

NOTES: GENERAL NOTE:

X1 LEDEXIT SIGN WITH LED EGRESS HEADS, THERMOPLASTIC HOUSING,NI-CAD BATTERY, RED LETTERING.

LITHONIA LHQM LED R UNIVERSAL / 120 1

D1 13.1W LED 3" DOWNLIGHTPHILIPS

LIGHTOLIER

C3L085-N-UZ10V-VBC3L085-DL-01-35K-8-VBC3L-DL-W-CCD-W

RECESSED / 120 1

B2 51.4W LED 2x4 RECESSED EDGE-LIT FLAT PANEL LITHONIAEPANL 2X4 5400LM 80CRI 35KMIN10 ZT MVOLT

RECESSED / 120 2

B1 32.10W LED 2x2 RECESSED EDGE-LIT FLAT PANEL LITHONIAEPANL 2X2 3400LM 80CRI 35KMIN10 ZT MVOLT

RECESSED / 120 2

TYPE LAMPS DESCRIPTIONS MFR CATALOG NO. OR SERIES MOUNTING / VOLTAGE NOTES

LUMINAIRE SCHEDULE

N.T.S.1REID 401/402 LIGHTING CONTROL DIAGRAM

WA

SS

SS

WA

WA

WA

J

WA

WA

WA

S S S

SSS

S S S

SSS

M

M

M

M

KK

WA

UP

UP

G

H

J

4 3 2 1

L

K

EXISTING WALL-MOUNT SPEAKERS & ASSOCIATED WIRING TO BE REMOVED BY CONTRACTOR (TYP. 4)

PROJECTOR (RELOCATE)

PROJECTOR (RELOCATE)

DEMO 6

DEMO 6

DEMO 6

DEMO 6

DEMO 6

DEMO 6

DEMO 6

EXISTING WIRELESS ACCESS POINT SHALL REMAIN. REMOVE AND PROTECT DURING CONSTRUCTION. RE-INSTALL ON NEW CEILING. COORDINATE LOCATION WITH MSU IT. (TYP)

DEMO

DEMO

6

6

G

H

J

4 3 2 1

L

K

1

2

2

8

3

3

8

CLASSROOM

401-402

5

PROJECTOR

PROJECTOR

5

2

PROJECTOR

2

PROJECTOR

RECESSED

CLOCK9

MOTORIZED PROJECTOR SCREEN

MOTORIZED PROJECTOR SCREEN

Z- 17

Z- 17

Z- 19

Z- 19

11

Z- 21 Z- 21

Z- 21Z- 21

Z- 23Z- 23

Z- 23 Z- 23

10

(TYP.)

10

(TYP.)

12

12

12

12

12

12 12

12

13

13

5

Z- 21 Z- 21 Z- 21 Z- 21 Z- 21 Z- 21

Z- 23 Z- 23 Z- 23 Z- 23 Z- 23 Z- 23

5

5

5

5

MOTORIZED SCREEN SWITCHES

5

14

14

14

15

DOC CAM

5

5

GENERAL ELECTRICAL NOTESA. ELECTRICAL DEVICES AND LIGHTS SHOWN IN GREY ARE EXISTING TO REMAIN.

ELECTRICAL DEVICES AND LIGHTS SHOWN IN DASHED BLACK & SPECIFICALLY NOTED AS 'DEMO' ARE TO BE DEMOLISHED, UNO.

B. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS, CONDUITS, DIFFUSERS, BOXES, AND OTHER ITEMS THROUGHOUT THIS PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.

C. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING OF FLOORS, WALLS, CEILINGS, AND ROOFS TO PERFORM THE REQUIRED WORK DEPICTED IN THESE DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL PATCHING OF HOLES TO THE SATISFACTION OF THE ARCHITECT/ENGINEER.

NOTES:1. FIELD VERIFY FINAL LOCATION. COORDINATE WITH PODIUM AND MSU IT.2. PAINT VERTICAL WALL CHANNEL TO MATCH WALL COLOR.3. INCLUDE ALL REQUIRED COMPONENTS AND MANUFATURER ACCESSORIES FOR A COMPLETE SYSTEM.

END COMPONENT AS REQUIRED: CONNECTRAC IN-EC, OR EQUAL.

AV/DUPLEX RECEPTACLE COMBO BOX: CONNECTRAC

PS-A-288, OR EQUAL.IN-CARPET WIREWAY:

CONNECTRAC IN-048-GR, OR EQUAL

VERTICAL WALL CHANNEL TO CEILING: CONNECTRAC

AC-WC-144-AL, OR EQUAL

FLOOR

WALL

PROJECT

LOCATIONNOT IN SCOPE

NOT IN SCOPE

4

LOCATION OF EXISTING ELECTRICAL PANEL 'Z'(ROOM 457)

LOCATION OF EXISTING ELECTRICAL PANELS 'H' & 'I'(ROOM 438CU)

7

KEY NOTES:#

No. 60006 PE

RYAN P.

MARONEY

MONTA NA

L IC ENSED

PR

OF

ESSIONA L ENGIN

EE

R

REV. DESCRIPTION DATE

REVIEWED BY:

DRAWN BY:

SHEET

DATE

SHEET TITLE

MO

NT

AN

AS

TA

TE

UN

IV

ER

SIT

Y

MSU-CPDCMONTANA STATE UNIVERSITY

BOZEMAN, MONTANA

PHONE: 406.994.5413

FAX: 406.994.5665

Consultant #:

3821-043

MS

U C

LA

SS

RO

OM

RE

NO

VA

TIO

NS

2019

RE

ID H

AL

L 4

01

, 4

02

-1

00

% C

D S

ET

RPMGLS

POWER & SIGNAL

PLANS - REID

401/402

E101

01/23/2019

PPA#18-2170

RE

ID

HA

LL

RO

OM

S 4

01 &

402

1/8" = 1'-0"1REID 401/402 POWER & SIGNAL DEMOLITION PLAN

1/8" = 1'-0"2REID 401/402 POWER & SIGNAL RENOVATION PLAN

1 PROVIDE IN-CARPET & VERTICAL WIREWAY SYSTEM PER DETAIL 3 ON THIS SHEET.

RE-ROUTE 120V FEEDER AS REQUIRED FROM EXISTING PROJECTOR LOCATION TO NEW PROJECTORS. RE-USE EXISTING CIRCUIT. COORDINATE EXACT LOCATION WITH MSU AV PRIOR TO ROUGH-IN.

PROVIDE SURFACE-MOUNT RACEWAY FOR NEW RECEPTACLES AS SHOWN. SEE ARCHITECTURAL PLANS FOR MOUNTING HEIGHTS OF RACEWAY & RECEPTACLES. PROVIDE SERIES V700 WIREMOLD OAE.

RE-USE EXISTING RECEPTACLE FEEDER(S) FROM EXISTING ELECTRICAL PANEL 'H' & 'I' INTO ROOMS 401/402.

CIRCUIT NOTED RECEPTACLE VIA EXISTING RECEPTACLE CIRCUIT(S) IN ROOM. FIELD VERIFY EXACT AS-BUILT CIRCUITING.

REMOVE EXISTING DEVICE, RACEWAY, AND IT'S CIRCUIT, BACK TO NEAREST UPSTREAM DEVICE TO MAINTAIN ORIGINAL CIRCUIT CONTINUITY.

PROVIDE NEW 20A 1P BREAKERS AS REQUIRED IN EXISTING PANEL 'Z' (SQUARE D NQOD 225A PANEL) FOR NEW CIRCUITING SHOWN IN VIEW #2 ON THIS SHEET.

RECEPTACLES ON THE NORTH & SOUTH WALLS TO BE RECESSED IN NEW WOOD PANEL WALLS.

PROVIDE ROUGH-IN ONLY FOR POE CLOCK PER ARCHITECTURAL DETAIL #9 ON SHEET A200.

MSU TO FURNISH AND WIRE SPEAKERS. CONTRACTOR TO INSTALL. COORDINATE EXACT LOCATION WITH MSU AV PRIOR TO ROUGH-IN.

PROVIDE SERIES 2400D DIVIDED WIREMOLD OAE TO MOTORIZED SCREEN KEYED SWITCHES. SHARE WIREMOLD WITH LIGHTING CONTROLS WIRING. STACK KEYED SWITCHES DIRECTLY ABOVE LIGHTING CONTROL SWITCHES. ROUTE WIREMOLD TIGHT TO WINDOW.

UNDER ADD ALTERNATE, PROVIDE FIRE RATED POKE-THROUGH FLOOR BOXES. COORDINATE EXACT LOCATION WITH ARCHITECT AND MSU PRIOR TO ROUGH-IN.

REMOVE EXISTING RACEWAY BETWEEN TWO NOTED DEVICES, AND RE-ROUTE DIRECTLY ABOVE THE BASE ALONG THE WALL VIA NEW SERIES V700 WIREMOLD OAE. REPLACE DEVICES AS WELL TO MATCH THE REST OF THE ROOM.

MOTORIZED SCREENS & ALL ASSOCIATED POWER/CONTROL SHALL BE PRICED UNDER ADD ALTERNATE. SEE ARCHITECTURAL FOR ALTERNATE DESCRIPTIONS. BASE BID TO INCLUDE MANUAL SCREENS (NO POWER).

CEILING-MOUNT DOCUMENT CAMERA & ASSOCIATED POWER SHALL BE PRICED UNDER ADD ALTERNATE. SEE ARCHITECTURAL FOR ALTERNATE DESCRIPTIONS. ASSOCIATED IT/AV WIRING PROVIDED BY MSU.

2

3

4

5

6

N.T.S.3ELECTRICAL IN-CARPET & VERTICAL WIREWAY DETAIL

1" = 30'-0"4LEVEL 4 OVERALL PLAN

7

8

9

10

11

12

13

14

15

DD

DD

DD

R4

LV

Dabcde

LV

Dabcde

OS

OS

P

LV

Dabcde

P

R4

KEY NOTES:# GENERAL ELECTRICAL NOTESA. ELECTRICAL DEVICES AND LIGHTS SHOWN IN GREY ARE EXISTING TO REMAIN.

ELECTRICAL DEVICES AND LIGHTS SHOWN IN DASHED BLACK & SPECIFICALLY NOTED AS 'DEMO' ARE TO BE DEMOLISHED, UNO.

B. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS, CONDUITS, DIFFUSERS, BOXES, AND OTHER ITEMS THROUGHOUT THIS PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.

C. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING OF FLOORS, WALLS, CEILINGS, AND ROOFS TO PERFORM THE REQUIRED WORK DEPICTED IN THESE DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL PATCHING OF HOLES TO THE SATISFACTION OF THE ARCHITECT/ENGINEER.

G

H

J

4 3 2 1

L

K

2

2

2

2

3(TYP)

2

CLASSROOM

401-402 6 (TYP)

G

H

J

4 3 2 1

L

K

B1

B2

B1

B1

B2

B1

B1

B2

B1

B1

B2

B1

B1

B2

B1

B1

B2

B1

B1

B2

B1

B1

B2

B1

D1D1D1D1D1

D1

D1

D1

D1D1D1D1D1

D1D1D1D1D1

D1D1D1D1D1

D1

D1

D1c

c

c

c

c

c

d

d

d

d

d

d

a

a

a

a

a

a

b

b

b

b

b

b

eeeee

e

e

e

eeeee

eeeee

eeeee

e

e

e

CLASSROOM

401-402

1 (TYP)

abc

X1

X14

5

5

D1e

D1e

D1e

D1e

7

7

7

d

b

de

No. 60006 PE

RYAN P.

MARONEY

MONTA NA

L IC ENSED

PR

OF

ESSIONA L ENGIN

EE

R

REV. DESCRIPTION DATE

REVIEWED BY:

DRAWN BY:

SHEET

DATE

SHEET TITLE

MO

NT

AN

AS

TA

TE

UN

IV

ER

SIT

Y

MSU-CPDCMONTANA STATE UNIVERSITY

BOZEMAN, MONTANA

PHONE: 406.994.5413

FAX: 406.994.5665

Consultant #:

3821-043

MS

U C

LA

SS

RO

OM

RE

NO

VA

TIO

NS

2019

RE

ID H

AL

L 4

01

, 4

02

-1

00

% C

D S

ET

RPMGLS

LIGHTING PLANS -

REID 401/402

E102

01/23/2019

PPA#18-2170

RE

ID

HA

LL

RO

OM

S 4

01 &

402

1/8" = 1'-0"1REID 401/402 LIGHTING DEMOLITION PLAN

1/8" = 1'-0"2REID 401/402 LIGHTING RENOVATION PLAN

1 ALL NEW LIGHTING IN THIS SPACE SHALL BE CIRCUITED VIA EXISTING BRANCH CIRCUIT PREVIOUSLY USED FOR LIGHTING. PROVIDE NEW CONTROLS AS SHOWN. SEE LUMINAIRE SCHEDULE AND LIGHTING CONTROLS DETAIL ON SHEET E001.

DEMOLISH EXISTING DIMMERS AND OTHER LIGHTING CONTROLS WITHIN THIS SPACE.

DEMOLISH EXISTING LIGHT FIXTURES. CIRCUITS TO REMAIN FOR NEW LIGHTING.

PROVIDE SERIES 2400D DIVIDED WIREMOLD OAE TO LIGHTING CONTROL SWITHES. SHARE WIREMOLD WITH KEYED SWITCHES. STACK KEYED SWITCHES DIRECTLY ABOVE LIGHTING CONTROL SWITHES. ROUTE WIREMOLD TIGHT TO WINDOW.

ROUTE WIREMOLD DIRECTLY INTO SURFACE MOUNTED EXIT SIGN. DO NOT UTILIZE BACK BOX OR JUNCTION BOX WHERE VISIBLE.

SALVAGE ALL DEMO'D LIGHTING IN THIS SPACE BACK TO OWNER FOR FUTURE USE.

PROVIDE 5-GANG BOX FOR (5) LMDM-101 DIGITAL DIMMERS. SEE DETAIL #1 ON SHEET E001.

2

3

4

5

2

6

7

F

F

G

H

J

4 3 2 1

L

K24"x16"

20"x12"

20"x12"

24"x16"

IN 3RD FLOOR CEILING

IN 3RD FLOOR CEILING

T

T

18"x12" 18"x10" 12"x10" 12"x6"

18"x12" 18"x10" 12"x10" 12"x6"

1

2

2

2

2

1 1 1

1 1 1 1

18"X12" UP FROM 3RD FLOOR

(E)

(E)

(E)

(E)

(E)

CLASSROOM

401-402

CLASSROOM

401-402

5

5

G

H

J

4 3 2 1

L

K

18"X12" UP FROM 3RD FLOOR

R-1

1000

R-11000

R-1

1000

R-1

1000

18"x12"

18"x12"18"x10"

18"x10"12"x10"

12"x10" 12"x6"

12"x6"

(TYP 4)

3

3

3

3

S-1

500

(TYP 4)

S-1

500

IN 3RD FLOOR CEILING

IN 3RD FLOOR CEILING24"x16"

24"x16"

(E)

(E)

(E)

CLASSROOM

401-402

CLASSROOM

401-402

4

4

T

T

AIR FLOW

SUPPLY DUCTWORK

45 DEG. ENTRANCETAP

SUPPLY GRILLE -SEE SCHEDULE FOR DETAILS

MANUAL BALANCING DAMPER

A. LOCATIONS AND DIMENSIONS OF EXISTING FACILITIES IDENTIFIED ON THIS DRAWING ARE APPROXIMATE AND REPRESENT THE BEST AVAILABLE INFORMATION BASED ON A COMBINATION OF FIELD INVESTIGATIONS AND VARIOUS DESIGN AND RECORD DRAWINGS AVAILABLE AT THE TIME OF THE DESIGN. FIELD VERIFY LOCATIONS AND DIMENSIONS PRIOR TO AND DURING PERFORMANCE OF THE WORK AND NOTIFY THE ARCHITECT/ENGINEER OF ANY MAJOR DISCREPANCIES.

B. ALL EXISTING PLUMBING EQUIPMENT, PIPING SHOWN AS DARK AND DASHED SHALL BE DEMOLISHED. EXISTING MECHANICAL EQUIPMENT SHOWN LIGHT WITH SOLID LINES IS TO REMAIN.

C. THE PLUMBING CONTRACTOR SHALL COORDINATE SALVAGE OF ALL REMOVED EQUIPMENT IN GOOD CONDITION WITH THE OWNER. THE PLUMBING CONTRACTOR SHALL DISPOSE OF ALL UNWATED EQUIPMENT.

D. COORDINATE ANY ROOF, WALL, CEILING AND FLOOR PATCH AND REPAIR WORK REQUIRED BY THE DEMOLITION OF PLUMBING SYSTEM WITH THE CONSTRUCTION MANAGER.

E. CONCRETE SLAB CUTTING REGIONS SHOWN ON DRAWINGS ARE APPROXIMATE AND MUST BE FIELD COORDINATED PRIOR TO THE CUTTING OF THE SLAB.

GENERAL MECHANICAL

DEMOLITION NOTES

A.) IT SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR TO FIELD COORDINATE THE LOCATION OF EQUIPMENT ROUTING OF ALL DUCTWORK AND PIPING WITH ALL OTHER TRADES.

B.) IT SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR TO REVIEW THE DRAWINGS FOR ALL DISCIPLINES AND PROVIDE ALL LABOR AND MATERIALS REQUIRED FOR A COMPLETE INSTALLATION.

C.) COORDINATE THE INSTALLATION OF GRILLES, REGISTERS AND DIFFUSERS WITH THE ARCHITECTURAL REFLECTED CEILING PLANS AND THE ELECTRICAL LIGHTING PLANS.

D.) VERIFY THE LOCATION OF THERMOSTATS AND SENSORS WITH THE ARCHITECT AND ENGINEER PRIOR TO INSTALLATION. INSTALL THERMOSTATS 48" ABOVE FINISHED FLOOR PER ADA REQUIREMENTS.

E.) PROVIDE AND INSTALL SEISMIC BRACING FOR ALL EQUIPMENT, DUCTWORK AND PIPING PER THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE.

F.) FLEXIBLE DUCTWORK BETWEEN BRANCH DUCTS AND GRILLES, REGISTERS OR DIFFUSERS SHALL BE LIMITED TO 5FT.

G.) PROVIDE AND INSTALL FIRE, SMOKE AND/OR COMBINATION SMOKE/FIRE DAMPERS WHERE DUCTWORK PASSES THROUGH FIRE RATED ASSEMBLIES. ASSOCIATED DUCT DETECTORS SHALL BE ADDRESSABLE. SMOKE DAMPERS AND COMBINATION SMOKE/FIRE DAMPERS SHALL INCLUDE A KEYED REMOTE TEST SWITCH LOCATED IN AN ACCESSIBLE LOCATION. FIELD COORDINATE THE LOCATION OF TEST SWITCHES WITH THE ARCHITECT AND ENGINEER PRIOR INSTALLATION.

H.) SEAL ALL DUCT AND PIPE PENETRATIONS THROUGH FIRE RATED ASSEMBLIES WITH A UL-APPROVED FIRE STOP SYSTEM.

I.) PROVIDE ACCESS DOORS TO ALLOW SERVICE AND INSPECTION OF EQUIPMENT, VALVES, DAMPERS AND DEVICES INSTALLED ABOVE NON-REMOVABLE CEILINGS.

J.) PROVIDE REMOTE CONTROLLED DAMPER ACTUATORS FOR BALANCING DAMPERS INSTALLED IN INACCESSIBLE LOCATION. PROVIDE RUSKIN ZPD25 OR APPROVED EQUAL.

GENERAL MECHANICAL NOTES

KEY NOTES:#

AIRFLOW

RATED WALL ASSEMBLY

DUCT LINER WHEREINDICATED ONPLANS

METAL NOSING ONEXPOSED LINER EDGES

FASTEN MOUNTING ANGLES TO DAMPERSLEEVE WITH BOLTS, SCREWS, RIVETS ORWELDS AS REQUIRED BY MANUFACTURE'SINSTRUCTIONS

DUCT

GALVANIZED STEEL DAMPER SLEEVE (GA. AS REQUIRED BY DUCT SIZE/CONNECTION)

APPROVED SLIP-JOINT DUCT CONNECTION

STEEL MOUNTING ANGLES OR OTHER APPROVED MATERIALFASTEN DAMPER TO SLEEVE W/ BOLTS,

SCREWS, RIVETS OR WELDS AS REQ'DBY MFR. IF NOT FURNISHEDINTEGRALLY W/ DAMPER

DAMPER ACCESSDOOR LABELED "FIREDAMPER" SIZE ASREQUIRED FORADEQUATE ACCESS

UL CLASSIFIED CURTAIN TYPEFIRE DAMPER WITH BLADES OUTOF AIRSTREAM

EXPANSION CLEARANCE AS REQ'D BY MFR BETWEEN DAMPER/SLEEVE AND WALL OPENING, MINIMUM 1/4"

NOTE:INSTALLATION SHALL COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, U.L. STANDARD 555 AND NFPA 90A

4' - 11 3/4"

2' - 5 15/16"1" MINIMUM OVERLAP OF WALL (4 SIDES) BY MOUNTING ANGLES

SLEEVE TO EXTEND 6" MIN.BEYOND WALL LINE

No. 20181 PE

MATTHEW W.

CARR

MONTA NA

L IC ENSED

PR

OF

ESSIONA L ENGIN

EE

R

REV. DESCRIPTION DATE

REVIEWED BY:

DRAWN BY:

SHEET

DATE

SHEET TITLE

MO

NT

AN

AS

TA

TE

UN

IV

ER

SIT

Y

MSU-CPDCMONTANA STATE UNIVERSITY

BOZEMAN, MONTANA

PHONE: 406.994.5413

FAX: 406.994.5665

Consultant #:

3821-043

MS

U C

LA

SS

RO

OM

RE

NO

VA

TIO

NS

2019

RE

ID H

AL

L 4

01

, 4

02

-1

00

% C

D S

ET

CMSMWC

MECHANICAL PLAN -

REID 401, 402

M101

01/23/2019

PPA#18-2170

RE

ID

HA

LL

RO

OM

S 4

01 &

402

1/8" = 1'-0"1REID 401, 402 - DEMOLITION PLAN

NOTES: PROVIDE MANUAL BALANCING DAMPER AT LOCATIONS WHERE A SPECIFIED AIR VOLUME IS REQUIRED I.E. FOR SUPPLY AND EXHAUST ONLY. COORDINATE FRAME AND MOUNTING TYPE WITH CEILING TYPES. SEE ARCHITECTURAL PLANS FOR CEILING TYPES. THE CONTRACTOR SHALL BERESPONSIBLE TO PROVIDE ALL FITTINGS AND ACCESSORIES REQUIRED FOR A COMPLETE INSTALLATION. SCHEDULED N.C. VALUES ARE VALID FOR SCHEDULE AIR FLOW ONLY AND REPRESENT A MAXIMUM ACCEPTABLE N.C. VALUE. SUBSTITUTED EQUIPTMENT SHALL HAVE N.C. VALUE EQUAL TO OR BELOWTHE SCHEDULES N.C. AT THE AIR FLOW LISTED ON THE PLANS. COORDINATE FINISH WITH ARCHITECT.

R-1 PRICE LBPH FLOOR MOUNT LINEAR BAR RETURN GRILLE RETURN AIR 1000 30 - - 0.10 36 x 12 DUCT MOUNTED ALUMINUM BY ARCH SEE NOTES

S-1 PRICE 21 26"x6" LINEAR BAR SUPPLY GRILLE SUPPLY AIR 500 16 34 0.043 26 x 6 DUCT MOUNTED ALUMINUM BY ARCH SEE NOTES

MARK MFGR MODEL DESCRIPTION FUNCTION MAX CFMNC AT MAX

CFMTHROW AT MAX

CFM (FT)PRESSURE DROP AT MAX CFM

(in. W.C.)NECK SIZE

(W"xH")DAMPER TYPE MATERIAL FINISH REMARKS

GRILLE, REGISTER AND DIFFUSER SCHEDULE

1/8" = 1'-0"2REID 401, 402 - MECHANICAL PLAN

N.T.S.3RECTANGULAR DUCT MOUNTED GRILLE DETAIL

1. DEMOLISH 26"X5" SUPPLY DIFFUSER AND TAP BACK TO MAIN.2. DEMOLISH 36"X12" RETURN FLOOR GRILLE, TAP TO REMAIN FOR REUSE.3. INSTALL FIRE DAMPER IN EXISTING RETURN DUCT BENEATH THE FLOOR

LEVEL, RUSKIN MODEL IBDT OR EQUAL. FIRE CAULK ANY DUCT JOINTS PRIOR TO INSTALLATION. COORDINATE FIRE DAMPER INSTALLATION WITH INSTALLATION OF NEW RETURN GRILLE.

4. INSTALL FIRE DAMPER AT SHAFT WALL PENETRATION. PROVIDE FIRE DAMPER RUSKIN MODEL IBDT OR EQUAL. FIRE CAULK ANY DUCT JOINGS PRIOR TO INSTALLATION.

5. EXISTING PNEUMATIC THERMOSTAT TO REMAIN. MECHANICAL CONTRACTOR SHALL RECALIBRATE THERMOSTAT INTO CORRECT OPERATING RANGE.

N.T.S.4FIRE DAMPER AT WALL DETAIL

JeffD
Text Box
CONTROLS NOTE: CONTRACTOR TO CONTACT CHAD SCHOENWWALD OF ELECTRO-CONTROLS, 406.580.6521 TO PERFORM AND AND ALL WORK RELATED TO THERMOSTAT OR CONTROL SYSTEMS.