16
FORM DOC 120 A MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 1/16 This document is available at www.alma-alma.fr OPERATING MANUAL MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS B 2016/06/16 Modification of the arm error with correction for the ETALCOMPT API DSM AH A 2016/04/04 Creation DSM AH Issue Date Nature of modifications Writer Approver

MU 7076 EN B - Alma Carbovac · FORM DOC 120 A MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 4/16 This document is available at • In the computer folder, open the

  • Upload
    others

  • View
    18

  • Download
    7

Embed Size (px)

Citation preview

Page 1: MU 7076 EN B - Alma Carbovac · FORM DOC 120 A MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 4/16 This document is available at • In the computer folder, open the

FORM DOC 120 A

MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 1/16

This document is available at www.alma-alma.fr

OPERATING MANUAL

MU 7076 EN B

EXCEL FILES FOR MASTER METER APPLICATIONS

B 2016/06/16 Modification of the arm error with correction for the ETALCOMPT API DSM AH

A 2016/04/04 Creation DSM AH

Issue Date Nature of modifications Writer Approver

Page 2: MU 7076 EN B - Alma Carbovac · FORM DOC 120 A MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 4/16 This document is available at • In the computer folder, open the

FORM DOC 120 A

MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 2/16

This document is available at www.alma-alma.fr

CONTENTS

1 VOCABULARY ....................................................................................................................... 3

2 SPECIFIC TOOLS .................................................................................................................... 3

3 UPLOADING EXCEL FILES ....................................................................................................... 3

3.1 API ETALCOMPT, ALMASCOPE and BLENDER ................................................................. 3

3.2 LPG ETALCOMPT+ ......................................................................................................... 3

4 EXCEL FILES CONTENT ........................................................................................................... 5

4.1 ALMASCOPE ALM00xxxxx ............................................................................................. 5

4.2 ETALCOMPT BLENDER MEL00xxxxx ............................................................................... 7

4.3 API ETALCOMPT API00xxxxx ......................................................................................... 9

4.4 LPG ETALCOMPT+ ....................................................................................................... 12

RELATED DOCUMENTS ................................................................................................................ 16

Page 3: MU 7076 EN B - Alma Carbovac · FORM DOC 120 A MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 4/16 This document is available at • In the computer folder, open the

FORM DOC 120 A

MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 3/16

This document is available at www.alma-alma.fr

1 VOCABULARY

CTD+: Data transfer key.

2 SPECIFIC TOOLS

� CTD+ � USB cable

3 UPLOADING EXCEL FILES

3.1 API ETALCOMPT, ALMASCOPE and BLENDER

At the end of a verification exercise with an API ETALCOMPT, an ALMASCOPE or an ETALCOMPT BLENDER, the data backup is made as follows: • Retrieve the measurement results of the ETALCOMPT by using the CTD+ • Connect the key to the PC with an USB cable • Open the file on the CTD+

� ALM00xxxxx.xls for the ALMASCOPE, � MEL00xxxxx.xls for the MELANGEUR � API00xxxxx.xls for the API ETALCOMPT

(xxxxx is the reference standard) If the dialog box ‘Missing or not compatible file’ opens, csv files are missing on the CTD+ (P, E or J for the API ETALCOMPT). Those files are useful for retrieving data in the Excel file

• Name the Excel file and save it on the computer as: � A 97-2003 Excel file (*.xls) to save macros. When you open the file again if the

csv files are missing, the dialog box ‘Missing or not compatible file’ should open, then click on OK OR

� A Open XML Strict spreadsheet (*.xlsx) to save the Excel format without macros OR

� PDF file (*.pdf) to save the file into a non-editable format. • Close the CTD+ and disconnect it.

3.2 LPG ETALCOMPT+

At the end of a verification exercise with an LPG ETALCOMPT+, the data backup is made as follows: • Retrieve the measurement results of the ETALCOMPT by using the CTD+ • Connect the key to the PC with an USB cable • Copy the CTD+ files to a folder you have created on your computer Note: The file named Master.xls must never be modified. It must remain in the same folder as the file named GPL00xxxxx.xls. • Close the CTD+ and disconnect it

Page 4: MU 7076 EN B - Alma Carbovac · FORM DOC 120 A MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 4/16 This document is available at • In the computer folder, open the

FORM DOC 120 A

MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 4/16

This document is available at www.alma-alma.fr

• In the computer folder, open the file named GPL00xxxxx.xls which is automatically updated. The table is titled: ‘liste des fichiers créés d’après les vérifications effectuées avec l’ETALCOMPT GPL+’. This list comprises the names of the reports for each meter verified at a given date. For example 123ab94_20160318.xls is the name of the verification report of the meter #123ab94 for tests performed on the 18th of March, 2016.

• Verification reports are saved in the folder named Vehicles. Open the relevant file 123ab94_20160318.xls for example Note: the folder Vehicles is automatically created on opening the file named GPL00xxxxx.xls. If it has already been created on the computer, its content is not erased.

• These reports can be renamed and saved in another folder on the computer. They can be saved as: � A 97-2003 Excel file (*.xls) to save macros. When you open the file again if the

csv files are missing, the dialogue box ‘Missing or not compatible file’ should open, then click on OK OR

� A Open XML Strict spreadsheet (*.xlsx) to save the Excel format without macros OR

� PDF file (*.pdf) to save the file into a non-editable format.

Page 5: MU 7076 EN B - Alma Carbovac · FORM DOC 120 A MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 4/16 This document is available at • In the computer folder, open the

FORM DOC 120 A

MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 5/16

This document is available at www.alma-alma.fr

4 EXCEL FILES CONTENT

4.1 ALMASCOPE ALM00xxxxx

Page 6: MU 7076 EN B - Alma Carbovac · FORM DOC 120 A MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 4/16 This document is available at • In the computer folder, open the

FORM DOC 120 A

MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 6/16

This document is available at www.alma-alma.fr

• Date: Date of the test • Time: Time of the test • Additive ID: Identifier of the verified additive meter • Main product volume: Volume of product with additive • Expected dose: Theoretical additive dose set in ALMASCOPE • Additive indicator volume: Volume counted by the verified meter • Almascope volume: Volume counted by the ALMASCOPE • Additive meter satisfaction rate / theoretical: Satisfaction rate between the actual

volume injected by the additive meter and the expected volume, according to the volume of main product and the programmed setting. The cell is red if the result is less than 95% or greater than 105%

• Almascope satisfaction rate / theoretical: Satisfaction rate between the actual volume injected by the ALMASCOPE and the expected volume, based on the volume of main product and the programmed setting. The cell is red if the result is less than 95% or greater than 105%.

Page 7: MU 7076 EN B - Alma Carbovac · FORM DOC 120 A MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 4/16 This document is available at • In the computer folder, open the

FORM DOC 120 A

MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 7/16

This document is available at www.alma-alma.fr

4.2 ETALCOMPT BLENDER MEL00xxxxx

Page 8: MU 7076 EN B - Alma Carbovac · FORM DOC 120 A MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 4/16 This document is available at • In the computer folder, open the

FORM DOC 120 A

MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 8/16

This document is available at www.alma-alma.fr

• Date: Date of the test • Time: Time of the test • ID du mélangeur dépôt Additive ID: Identifier of the verified blending system • Main product volume: Volume of product that has been blended • Expected blending rate: Percentage of secondary product to be injected into the main

product • Volume of the loading terminal blender indicator: Volume counted by the verified

blending system • Etalcompt volume: Volume counted by the ETALCOMPT BLENDER • Loading terminal blender satisfaction rate / theoretical: Satisfaction rate between the

actual volume injected by the blending system and the expected volume, based on the volume of main product and the programmed setting. The cell is red if the result is less than 95% or greater than 105%

• Etalcompt satisfaction rate / theoretical: Satisfaction rate between the actual volume injected by the ETALCOMPT BLENDER and the expected volume, based on the volume of main product and the programmed setting. The cell is red if the result is less than 95% or greater than 105%.

Page 9: MU 7076 EN B - Alma Carbovac · FORM DOC 120 A MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 4/16 This document is available at • In the computer folder, open the

FORM DOC 120 A

MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 9/16

This document is available at www.alma-alma.fr

4.3 API ETALCOMPT API00xxxxx

Page 10: MU 7076 EN B - Alma Carbovac · FORM DOC 120 A MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 4/16 This document is available at • In the computer folder, open the

FORM DOC 120 A

MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 10/16

This document is available at www.alma-alma.fr

About calibration with gauge: • Date: Date of the calibration with gauge • Time: Time of the calibration with gauge • Family: Family of the product used for the calibration with gauge (distillate or petrol) • Product : Product used for the calibration with gauge • Arm identification: Identifier of the arm used for the calibration with gauge • Arm volume: Volume counted by the arm indicator • Arm error / gauge: Error of the arm from the gauge for the relevant family of product • Empty gauge temperature: Temperature of the empty gauge • Full gauge temperature: Temperature of the full gauge • Product height: Height of liquid in the gauge • T° corrected gauge volume: Temperature-compensated volume of liquid in the gauge • Etalcompt volume: Volume counted by the API ETALCOMPT • Average flow rate: Average flow rate of the calibration with gauge. This value can

make the test invalid: the cell is red if the average flow rate is less than the criterion ‘Min_Flo’ or greater than the criterion ‘Max_Flo’ of the API ETALCOMPT (Refer to MU7065 menu criteria)

• Under Qmin volume: Volume counted at a flow < Qmin during the calibration with gauge. This value can make the test invalid: the cell is red if the counted volume is greater than the criterion ‘V_q_Min’ of the API ETALCOMPT (Refer to MU7065 menu criteria)

• Etalcompt error / gauge: Error of the ETALCOMPT from the gauge for the relevant family of product. This value can make the test invalid: the cell is red if the error is greater than 0.5%.

About arm verification: • Date: Date of the arm verification • Time: Time of the arm verification • Loading arm: Arm identifier of the verified meter • Product : Product used for the verification • Product family: Family of the product used for the arm verification (distillate or petrol) • Arm indicator volume: Volume of product counted by the verified meter • Etalcompt volume with family correction: Volume of product counted by the

ETALCOMPT corrected with family error • Family correction used: Family correction calculated during the calibration with

gauge, applied according to the family of the product used for the arm verification. A red cell means that the arm test has been performed prior to the calibration.

• Average flow rate: Average flow rate of the arm verification. This value can make the test invalid: the cell is red if the average flow rate is less than the criterion ‘Min_Flo’ or greater than the criterion ‘Max_Flo’ of the API ETALCOMPT (Refer to MU7065 menu criteria)

• Volume measured under minimum flow rate: Volume counted at a flow < Qmin during the arm verification. This value can make the test invalid: the cell is red if the counted volume is greater than the criterion ‘V_q_Min’ of the API ETALCOMPT (Refer to MU7065 menu criteria)

Page 11: MU 7076 EN B - Alma Carbovac · FORM DOC 120 A MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 4/16 This document is available at • In the computer folder, open the

FORM DOC 120 A

MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 11/16

This document is available at www.alma-alma.fr

• Criterion flow rate / gauge flow rate: The arm test is valid if the average flow rate is between n% and m% of the flow rate of the calibration test. The percentage values are set in the menus ‘G_Min_q’ and ‘G_Max_q’ of the ETALCOMPT (Refer to MU7065 menu criteria). The test is invalidated if the criterion is not met

• Arm/Etalcompt calculated error without family correction: Arm error calculated by the ETALCOMPT. The family correction calculated during the calibration with gauge is not applied

• Arm/gauge calculated error with family correction: Error of the arm from the gauge. The family correction calculated during the calibration with gauge is applied. This value can make the test invalid: the cell is red if the error is greater than 0.1% (absolute value).

Page 12: MU 7076 EN B - Alma Carbovac · FORM DOC 120 A MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 4/16 This document is available at • In the computer folder, open the

FORM DOC 120 A

MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 12/16

This document is available at www.alma-alma.fr

4.4 LPG ETALCOMPT+

File GPL0040004.xls: List of files created according to the verification done with the LPG ETALCOMPT #40004

Page 13: MU 7076 EN B - Alma Carbovac · FORM DOC 120 A MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 4/16 This document is available at • In the computer folder, open the

FORM DOC 120 A

MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 13/16

This document is available at www.alma-alma.fr

File 12Cb124_2016_05_10.xls: Verification report of the meter #12Cb124 for tests performed on the 10th of May, 2016

Page 14: MU 7076 EN B - Alma Carbovac · FORM DOC 120 A MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 4/16 This document is available at • In the computer folder, open the

FORM DOC 120 A

MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 14/16

This document is available at www.alma-alma.fr

• Number plate: Identifier of the vehicle • Product used: Name of the product used for the test • Identification: Identifier of the LPG ETALCOMPT+ • Log (Q/nu) range: Range of the flow/viscosity factor given by the ETALCOMPT

calibration. The range is defined in the ETALCOMPT metrological mode: ‘qnu_Min’ et ‘qnu_Max’(Refer to MU7079 menu criteria)

• Calibration temperature: Calibration temperature of the LPG ETALCOMPT+ • Calibration pressure: Calibration pressure of the LPG ETALCOMPT+

• Coeff. for the temperature: Thermal expansion coefficient of the turbine (/°C) • Coeff. for the temperature: Pressure expansion coefficient of the turbine (/bar). • Polynomial coeff. A0: Coefficient given by the ETALCOMPT calibration • Polynomial coeff. A1: Coefficient given by the ETALCOMPT calibration • Polynomial coeff. A2: Coefficient given by the ETALCOMPT calibration • Polynomial coeff. A3: Coefficient given by the ETALCOMPT calibration • Date: Date of the test • Time: Time of the test • Flowrate: Average flow rate of the test • Difference of temperature between the 2 probes: Difference between both

temperature sensors • Difference of pressure between the 2 manometers: Difference between both pressure

sensors • Vapor pressure: This value can make the test invalid: the cell is red if the

ETALCOMPT pressure is less than the vapor pressure+1 bar • Temperature of the Etalcompt at the beginning: LPG ETALCOMPT+ temperature at

the beginning of the test • Temperature of the measuring instrument at the beginning: Temperature of the meter

at the beginning of the test • Etalcompt pressure: LPG ETALCOMPT+ pressure. This value can make the test

invalid: the cell is red if the difference between the meter pressure and the ETALCOMPT pressure is greater than 9 bar

• Measuring instrument pressure: Meter pressure. This value can make the test invalid: the cell is red if the difference between the meter pressure and the ETALCOMPT pressure is greater than 9 bar

• Temperature of the Etalcompt at the end: LPG ETALCOMPT+ temperature at the end of the test

• Volume read at the measuring instrument: Volume of product counted by the verified measuring system

• Volume read at the Etalcompt: Volume of product counted by the ETALCOMPT • Volume measured under minimum flow rate: Volume counted at a flow < Qmin during

the test. This value can make the test invalid: the cell is red if the counted volume is greater than the criterion ‘V_q_Min’ of the LPG ETALCOMPT+ (Refer to MU7079 menu criteria)

• Etalcompt average temperature: Average temperature of the LPG ETALCOMPT+ during the test

• Average difference temperature: Difference between the ETALCOMPT average temperature and the verified meter average temperature. This value can make the

Page 15: MU 7076 EN B - Alma Carbovac · FORM DOC 120 A MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 4/16 This document is available at • In the computer folder, open the

FORM DOC 120 A

MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 15/16

This document is available at www.alma-alma.fr

test invalid: the cell is red if the temperature difference is greater than 0.5°C (Cf. MU 7079)

• Calculated viscosity: Kinematic viscosity of the product, calculated according to the temperature

• Measurement log(Q/nu) coefficient: Flow/viscosity factor of the test. This value can make the test invalid: the cell is red if it is out of range log Q/ν set in metrological mode

• Measuring instrument volume, converted with Etalcompt conditions: Volume measured by the measuring system, restored to flowing conditions of the ETALCOMPT, taking into account the measured quantities and the temperature and pressure deviation

• Etalcompt corrected volume: Volume displayed by the ETALCOMPT, restored to temperature and pressure of its calibration, taking into account the flow/viscosity factor (Q/ν) compared with the result of its calibration

• Error : Relative error of the verified meter • Suggested K factor: Proposed new coefficient for the verified meter

Page 16: MU 7076 EN B - Alma Carbovac · FORM DOC 120 A MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 4/16 This document is available at • In the computer folder, open the

FORM DOC 120 A

MU 7076 EN B EXCEL FILES FOR MASTER METER APPLICATIONS Page 16/16

This document is available at www.alma-alma.fr

RELATED DOCUMENTS

MU 7065 Operating manual API ETALCOMPT

MU 7066 Operating manual ALMASCOPE

MU 7078 Operating manual ETALCOMPT BLENDER

MU 7079 Operating manual LPG ETALCOMPT+

FM 8012 Transfer the measurement results of the UNI indicator device to a computer