08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91
1
MULTI RF MANUAL
CONTENT
Forest Multi remote – 5201.00.X64X 2 Forest Multi wall switch RF – 5201.00.1470 4 Forest Multi wall switch LED – 5201.00.1480 4 Forest Multi receiver click-on – 5201.00.1362 5 Forest Shuttle S / L receiver programming – 5232.00.0000/1 5 Forest Multi receiver / wall switch for Shuttle M – 5201001360/1361 6 Forest FMS/BCS Multi receiver – 5201.01.1500
- programming remote 6 - wiring diagram 7
Tubular motor with build in receiver and electronic limit setting
- wiring diagram 8 - programming remote 9 - setting end limits 10
BS double shaft motor 24V – 3648.00.0000
- programming remote 12 - setting end limits 13
08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91
2
FOREST MULTI REMOTE – 520100X46X
TECHNICAL SPECIFICATION: ● 3V battery CR2430 ● transmit range indoors max. 30mtr ● battery life < 3 years ● working temperature -10°C - +50°C ● frequency 433.92MHz ● modes: manual, timer and dynamic timer (15 minutes + and -) ● transmit power max. 10mW ● each channel can control up to 20 receivers / motors
selected channel manual/auto/dynamic mode mode button open/up button
stop button time button close/down button P2 (LEARN) button
channel +/- battery slide (CR2430)
press mode to set press time for ~7sec. press buttons to press time to press time ~7sec. press time once mode to manual → 2 digits will blink change time toggle between until all digits more to finish ‘man’ on display hours/minutes stop blinking and start clock
BEFORE SETTING THE TIMER(S), SET THE CLOCK! NOTE: time between button presses max. 10 seconds
press mode to select channel press time for press buttons to press time to press mode to switch set mode to ~7sec. → hour change open time toggle between to close time auto or dynamic digits will blink hours/minutes press buttons to press time to press time for ~7sec. set to mode
change close time toggle between until digits stop auto or dynamic hours/minutes blinking → finished
SET TIME
SET TIMER (EACH CHANNEL SEPARATE):
08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91
3
FOREST MULTI REMOTE – 520100X46X
MODE EXPLANATION:
Mode manual (man): remote can only be used manually. Timer function is switched off.
Mode automatic (auto): timer is switched on, only for the selected channel. Select channel 00 (all channels) to engage on all timers.
Mode dynamic ( ): same as automatic mode, open and close time will vary + and – 15 minutes. FEATURES:
When channel select is set to channel 00, all the channels 1 to 15 will respond to open and close.
Default timer setting for every channel is: open 06:30AM, close 5:30PM.
Dynamic mode: timer will vary open and close time between + and – 15 minutes. The first day dynamic mode is used the time will not vary.
FREQUENT ASKED QUESTIONS: ● Q: Clock doesn’t start running after setting the time. A: Press time button on the back once more. ● Q: I can’t succeed setting the time or the timer. A: The interval between pressing different button must be within 10 seconds. ● Q: When I set a timer, the display shows Er:01 A: Time between open-time and close-time must be more than 30 minutes apart. ● Q: Timer only works on one channel. A: Only the selected channel will work as a timer. Use channel 00 to turn on all timers (all channels). ● Q: I can’t succeed programming a remote / wall switch RF to a receiver A: During programming, keep the remote / wall switch RF close to the receiver (max 0,5 mtr) COLOURS: 520100 1460 white gloss 520100 1461 white mat 520100 1461-wl white mat without logo 520100 3461 grey mat 520100 3461-wl grey mat without logo 520100 6460 black gloss 520100 6460-wl black gloss without logo 520100 6461 black mat 520100 6461-wl black mat without logo
BATTERY EMPTY: After changing the battery, only the time must be set. Programmed receivers and timers will stay in memory of remote. Please follow the local regulations for disposal of the empty battery.
08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91
4
FOREST MULTI WALL SWITCH RF - 5201001470
TECHNICAL SPECIFICATION: ● 3V battery CR2032 ● transmit range indoor max. 30mtr ● battery life < 3 years ● working temperature -10°C - +50°C ● frequency 433.92MHz ● each channel can control up to 20 receivers ● transmit power max. 10mW
P2 buttons (for programming tubular motor)
OPEN/UP button
STOP button
CLOSE/DOWN button
channel A channel B battery CR2032
BATTERY EMPTY: After changing the battery, programmed receivers will stay in memory of remote. Please follow the local regulations for disposal of the empty battery.
FOREST MULTI WALL SWITCH LED- 5201001480
TECHNICAL SPECIFICATION: ● 12V battery type 27A ● transmit range indoor max. 30mtr ● battery life < 3 years ● working temperature -10°C - +50°C ● frequency 433.92MHz ● each channel can control up to 20 receivers ● transmit power max. 10mW
OPEN/UP button
STOP button
CLOSE/DOWN button
+
channel A channel B P2 buttons (for programming tubular motor)
BATTERY EMPTY: After changing the battery, programmed receivers will stay in memory of remote. Please follow the local regulations for disposal of the empty battery.
08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91
5
FOREST MULTI RECEIVER CLICK ON – 5201001362
TECHNICAL SPECIFICATION: powered by Shuttle M
connect to port 1 of the Forest Shuttle M
working temperature -10°C - +50°C
controlled by Forest Multi Remote and Forest Multi Wall Switch RF
control led program button
press program button press program button press and hold the program led will light up led will light up button for 10 seconds until
led starts blinking
hold the remote within 0,5 mtr select channel and press from receiver. Select channel (1-15) close button and press open button
led blinks 3 times and will go off led will blink and will go off
FOREST SHUTTLE S / L RECEIVER PROGRAMMING
To programming a RF remote to a Shuttle S / L, press configuration button 3 times. LED3 is ON. Keep the button pressed for 4 seconds, LED will start blinking for 10 seconds. In these 10 seconds press OPEN button on remote to program the channel to the Shuttle. Same procedure, but press CLOSE instead of OPEN, will erase the programmed channel.
configuration button
PROGRAMMING REMOTE / WALL CANCEL ONE CHANNEL OF DELETE ALL PREVIOUS PROGRAMMED SWITCH TO RECEIVER: REMOTE / WALL SWITCH REMOTES / WALL SWITCHES:
08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91
6
5201001360 / 1361 5201011500
TECHNICAL SPECIFICATION SHUTTLE M RECEIVER: TECHNICAL SPECIFICATION FMS/BCS RECEIVER: ● powered by Shuttle M ● power 230Vac – 500W ● can also be used as wall switch ● controls one motor ● cable 0,5mtr → 5201001360 ● can also be used as wall switch ● cable 3,5mtr → 5201001361 ● terminal max 2,5mm² ● connect to port 1 of the Forest Shuttle M ● working temperature -10°C - +50°C ● working temperature -10°C - +50°C ● controlled by Forest Multi Remote and Forest Multi Wall Switch RF P2 program button control led
OPEN/UP button
STOP button
CLOSE/DOWN button
press program button, led will blink press program button, led will blink press stop and close button of receiver for ~6 sec.
press stop button press stop button led will blink and will go off
hold the remote within 0,5 mtr from receiver. Select channel (1-15) and press OPEN button: select channel and press CLOSE button:
led blinks 3 times and will go off led will blink and will go off
PROGRAMMING REMOTE / WALL CANCEL ONE CHANNEL OF DELETE ALL PREVIOUS PROGRAMMED SWITCH TO RECEIVER: REMOTE / WALL SWITCH REMOTES / WALL SWITCHES:
08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91
7
WIRING DIAGRAM FOREST FMS / TUBULAR MOTOR TO 5201011500
08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91
8
TUBULAR MOTOR
BUILD-IN RECEIVERAND ELECTRONIC LIMIT SETTING
TECHNICAL SPECIFICATION: ● 3416600099 – 6Nm, 33rpm, build-in receiver, electronic limit setting (110V) ● 3416600110 – 3Nm, 28rpm, build-in receiver, mechanical limit setting (230V) ● 3416600112 – 6Nm, 28rpm, build-in receiver, electronic limit setting (230V) ● 3416600116 – 13Nm, 14rpm, build-in receiver, electronic limit setting (230V) ● 3416600117 – 6Nm, 20rpm, build-in receiver, electronic limit setting,QUIET (230V) ● max. running time 4 min. ● protection degree IP44 (230V), class B (110V) ● has to be used with Multi remote and/or Multi wall switch RF
IMPORTANT 230V: use only wires BROWN (phase), BLUE (neutral) and GREEN/YELLOW (earth). The additional two wires (black and red) are for connecting the optional obstruction sensor. Make sure these two wires are not connected together and do NOT make contact with the power wires.
110V: use only wires BLACK (phase), WHITE (neutral) and GREEN (earth).
230Vac: PHASE L NEUTRAL EARTH
brown
blue
yellow/green
08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91
9
TUBULAR MOTOR
BUILD-IN MULTI RECEIVER AND ELECTRONIC LIMIT SETTING
NOTE: during programming, keep the remote or wireless wall switch within 2 mtr from the receiver/motor
first select the desired channel first select the desired channel first select the programmed channel press button on motor, motor will ①st remote: press P2 button two times press P2 button one time turn short to acknowledge
2x P2 1x P2
①
within 6 seconds:
press P2 button two times ②nd remote: press P2 button one time press STOP button one time
2x P2 1x P2
1x STOP
②
press OPEN-button one time motor will turn to acknowledge press P2 button one time
1x P2 1x OPEN
motor will turn to acknowledge motor will turn to acknowledge
to add another channel on the same remote: 1.select the programmed channel, 2.press button P2 of remote two times,
3.select desired channel and press P2 button motor will turn to acknowledge
CHANGING DIRECTION OF ROTATION To change the direction of rotation, keep green button on motor pressed for 7 sec, until motor turns to
acknowledge.
PROGRAMMING REMOTE / WALL ADD MORE REMOTES / WALL SWITCHES / CANCEL ALL REMOTES OR SWITCH TO TUBULAR MOTOR: CHANNELS TO TUBULAR MOTOR WALL SWITCHES
08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91
10
TUBULAR MOTOR
BUILD IN MULTI RECEIVER AND ELECTRONIC LIMIT SETTING
ADJUSTING UPPER AND LOWER END LIMITS: IMPORTANT: - when more motors are programmed to one channel, end limits of all motors will be adjusted
- during programming, keep the remote or wireless wall switch within 2 mtr from the receiver/motor press P2 button one time press OPEN button one time press P2 button one time 1x P2 1x P2 1x OPEN
press STOP button when required
motor will turn adjust to UPPER position height is reached. Press STOP button to acknowledge 5 times slowly for 1 seconds to confirm
5x STOP (slowly) press STOP button when required
motor will turn adjust to LOWER limit height is reached. Press STOP button to acknowledge 5 times slowly for 1 seconds to confirm 5x STOP (slowly) motor will turn to acknowledge, limits have been set successfully.
08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91
11
TUBULAR MOTOR
BUILD IN MULTI RECEIVER AND ELECTRONIC LIMIT SETTING
CANCELLATION OF UPPER AND LOWER END LIMITS: IMPORTANT: When cancelling end limits, all motors programmed to that channel will be cancelled press P2 button one time press CLOSE button one time press P2 button one time
1x P2 1x P2
motor will turn to acknowledge, limits has been set successfully. REVERSE DIRECTION SETTING: When motor is not running, press button on motor for ~ 7 seconds, until motor turns to acknowledge.
08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91
12
BS 24V DOUBLE SHAFT MOTOR - 36.4800.0000
BUILD-IN RECEIVER - ELECTRONIC LIMIT SETTING
TECHNICAL SPECIFICATION: ● 24Vdc, 16Watt ● nom. 0.8Nm – max. 1.0Nm
● 34 rpm ● max. running time 7 min. ● max. curtain weight 4 kg ● max. 5 cord rolls ● has to be used with Multi remote and/or Multi wall switch RF ● only to be used in Forest BS system and with Forest power supply for BS motor IMPORTANT: WHEN USING THE QUICK LOCK CORD ROLL, BE SURE TO LOCK THE CORD BEFORE USING THE MOTOR
first select the desired channel first select the desired channel first select the desired channel switch on power to the motor: switch on power to the motor: switch on power to the motor: motor will jog to acknowledge: motor will jog to acknowledge: motor will jog to acknowledge: within 10 seconds after jog, within 10 seconds after jog, within 10 seconds after jog, press OPEN button on remote press STOP button on remote press CLOSE button on remote
motor will jog to acknowledge: motor will jog to acknowledge: motor will jog to acknowledge:
NOTE: if you need to start over, switch off the power and wait at least 20 seconds before switching in the power
PROGRAMMING REMOTE REMOVE PROGRAMMED CHANNEL CHANGE MOTOR DIRECTION TO BS MOTOR:
08/2014 WDOC MULTI REMOTE www.forestgroup.nl v1.91
13
BS 24V DOUBLE SHAFT MOTOR - 36.4800.0000
BUILD-IN RECEIVER - ELECTRONIC LIMIT SETTING
press P2 button once, press P2 button once, press P2 button twice, motor will jog to acknowledge: motor will jog to acknowledge: motor will jog to acknowledge:
1xP2 1xP2 2xP2
press OPEN button on remote, press CLOSE button on remote, press OPEN button on remote, motor will jog to acknowledge: motor will jog to acknowledge: motor will jog to acknowledge:
1x 1x
1x
press P2 button once, press P2 button once, motor will jog to acknowledge: motor will jog to acknowledge: 1xP2 1xP2 press P2 button twice motor will jog to acknowledge:
2xP2 adjust desired upper end limit and adjust desired lower end limit and press P2 to save the upper limit: press P2 to save the lower limit 1x 1x P2 P2 press CLOSE button on remote, motor will jog twice to acknowledge motor will jog to acknowledge: motor will jog to acknowledge: 1x
SET UPPER END LIMIT SET LOWER END LIMIT DELETE LIMITS
DELETE ALL MEMORY