14
Multiple Stage Tandem Mass Spectrometry for identification of plastic contaminations in blood plasma using nano electrospray ionization Tobias Kind and Kwang-Hyeon Liu FiehnLab UC Davis 2009 http://fiehnlab.ucdavis.edu/staff/kind/Metabolomics/LipidAnalysis der: Anecdotal mass spectrometry ree Reuse License granted; Tobias Kind FiehnLab 2009

Multiple Stage Tandem Mass Spectrometry for identification of plastic contaminations in blood plasma using nano electrospray ionization Tobias Kind and

  • View
    231

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Multiple Stage Tandem Mass Spectrometry for identification of plastic contaminations in blood plasma using nano electrospray ionization Tobias Kind and

Multiple Stage Tandem Mass Spectrometryfor identification of plastic contaminations in blood plasma

using nano electrospray ionization

Tobias Kind and Kwang-Hyeon LiuFiehnLab UC Davis 2009

http://fiehnlab.ucdavis.edu/staff/kind/Metabolomics/LipidAnalysis

File under: Anecdotal mass spectrometryCC-by Free Reuse License granted; Tobias Kind FiehnLab 2009

Page 2: Multiple Stage Tandem Mass Spectrometry for identification of plastic contaminations in blood plasma using nano electrospray ionization Tobias Kind and

Instrumentation – robotized chip based nano electrospray ionizationwith linear iontrap

Advion NanoMate robot not shown

+

nanoESI chip LTQ Linear IonTrap

Page 3: Multiple Stage Tandem Mass Spectrometry for identification of plastic contaminations in blood plasma using nano electrospray ionization Tobias Kind and

Plasma_Pos_LowMS_60MSMS_CE45_01 #35-73 RT: 0.07-0.15 AV: 39 NL: 2.53E4T: ITMS + p ESI Full ms [200.00-1200.00]

640 650 660 670 680 690 700 710m/z

0

10

20

30

40

50

60

70

80

90

100

110

120

130

140

Rel

ativ

e A

bund

ance

650.55

703.64

678.64

654.18680.27

676.55 705.64690.55686.27664.55655.27648.55 701.64 706.55666.55660.45 707.55644.45

Full scan nanoESI positive mode with data dependent multiple stage tandem MS

We will fragment this ion with the awe-inspiring power ofMS/MS/MS/MS/MS/MS/MS/MS or MS8

Slowly repeat with me: MS1..MS2..MS3..MS4..MS5..MS6..MS7..MS8...

Page 4: Multiple Stage Tandem Mass Spectrometry for identification of plastic contaminations in blood plasma using nano electrospray ionization Tobias Kind and

What could it be?

Plasma_Pos_LowMS_60MSMS_CE45_01 #184 RT: 1.15 AV: 1 NL: 2.29E3T: ITMS + c ESI d Full ms2 [email protected] [170.00-675.00]

200 250 300 350 400 450 500 550 600 650m/z

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

100

Rel

ativ

e A

bund

ance

607.32

551.24

495.26

359.24 604.28 631.35540.52325.27 437.36212.44 283.20

MS^2precursor m/z 664.00 (ESI+)

-56.8

-112.76

-168.74

Page 5: Multiple Stage Tandem Mass Spectrometry for identification of plastic contaminations in blood plasma using nano electrospray ionization Tobias Kind and

Plasma_Pos_LowMS_60MSMS_CE45_01 #190 RT: 1.27 AV: 1 NL: 1.16E2T: ITMS + c ESI d Full ms8 [email protected] [email protected] [email protected] [email protected] 439.26 ...

100 150 200 250 300m/z

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

100R

elat

ive

Abu

ndan

ce233.03

214.97

153.09 251.07

291.17171.07309.12

174.99

MS^8 (ESI+)precursor m/z 327.00

Page 6: Multiple Stage Tandem Mass Spectrometry for identification of plastic contaminations in blood plasma using nano electrospray ionization Tobias Kind and

Plasma_Pos_LowMS_60MSMS_CE45_01 #184-190 RT: 1.15-1.27 AV: 7 NL: 2.99E3T: Composite spectrum MS8 664.00,607.32,551.33,495.34,439.26,383.17,327.06

100 200 300 400 500 600m/z

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

100

Rel

ativ

e A

bund

ance

551.29

607.32495.31

327.08 439.26383.17

233.03359.24 631.35540.52153.09 251.07 480.52419.50

56 Da

56 Da

56 Da

56 Da

56 Da

MS^8 composite tandem mass spectrumof precursor m/z 664.00 (ESI+)

Sample: KH Liu (FiehnLab)

Page 7: Multiple Stage Tandem Mass Spectrometry for identification of plastic contaminations in blood plasma using nano electrospray ionization Tobias Kind and

Plasma_Pos_LowMS_60MSMS_CE45_01.rawFriday, April 03, 2009

MS2 precursor 664.00|__MS3 precursor 607.32| |__MS4 precursor 551.33| | |__MS5 precursor 495.34| | | |__MS6 precursor 439.26| | | | |__MS7 precursor 383.17| | | | | |__MS8 precursor 327.06| | | | | | |__Composite spectrum MS8 664.00,607.32,551.33,495.34,439.26,383.17,327.06| | | | | | |__Single spectrum MS8 664.00,607.32,551.33,495.34,439.26,383.17,327.06 (190)| | | | | |__Composite spectrum MS7 664.00,607.32,551.33,495.34,439.26,383.17| | | | | |__Single spectrum MS7 664.00,607.32,551.33,495.34,439.26,383.17 (189)| | | | |__Composite spectrum MS6 664.00,607.32,551.33,495.34,439.26| | | | |__Single spectrum MS6 664.00,607.32,551.33,495.34,439.26 (188)| | | |__Composite spectrum MS5 664.00,607.32,551.33,495.34| | | |__Single spectrum MS5 664.00,607.32,551.33,495.34 (187)| | |__Composite spectrum MS4 664.00,607.32,551.33| | |__Single spectrum MS4 664.00,607.32,551.33 (186)| |__Composite spectrum MS3 664.00,607.32| |__Single spectrum MS3 664.00,607.32 (185)|__Single spectrum MS2 664.00 (184)

List of ions from precursor m/z 664.00 (ESI+)

List of product ions:m/z 664 , 607 ,551 ,495 ,439 ,383 ,327accurate masses see above

Page 8: Multiple Stage Tandem Mass Spectrometry for identification of plastic contaminations in blood plasma using nano electrospray ionization Tobias Kind and

Solutions – well Plasma – well Lipids use LipidMaps tools!

Current mass accuracy for unit mass resolution LTQ: 78 ppm (external calibration) or 0.046 Da @ 594.46 Da for reference purposesLipidMaps Tools used with M+H

CE(18:2(Ep)) 18 2 663.5711 0.4289 C45H75O3+CE(18:2(Ke)) 18 2 663.5711 0.4289 C45H75O3+CE(18:3(OH)) 18 3 663.5711 0.4289 C45H75O3+CE(18:1(Ep))-cyclo 18 1 663.5711 0.4289 C45H75O3+CE(18:1(Ke))-cyclo 18 1 663.5711 0.4289 C45H75O3+CE(18:2(OH))-cyclo 18 2 663.5711 0.4289 C45H75O3+CE(16:2(Ke,Ep2)) 16 2 663.4983 0.5017 C43H67O5+CE(16:2(Ke2,Ep)) 16 2 663.4983 0.5017 C43H67O5+CE(16:3(Ep,OO)) 16 3 663.4983 0.5017 C43H67O5+CE(16:3(Ke,OO)) 16 3 663.4983 0.5017 C43H67O5+CE(16:3(OH,Ep2)) 16 3 663.4983 0.5017 C43H67O5+CE(16:3(OH,Ke,Ep)) 16 3 663.4983 0.5017 C43H67O5+CE(16:3(OH,Ke2)) 16 3 663.4983 0.5017 C43H67O5+CE(16:4(OOH,Ep)) 16 4 663.4983 0.5017 C43H67O5+CE(16:4(OOH,Ke)) 16 4 663.4983 0.5017 C43H67O5+CE(16:4(OH,OO)) 16 4 663.4983 0.5017 C43H67O5+CE(16:4(OH2,Ep)) 16 4 663.4983 0.5017 C43H67O5+CE(16:4(OH2,Ke)) 16 4 663.4983 0.5017 C43H67O5+CE(16:5(OH,OOH)) 16 5 663.4983 0.5017 C43H67O5+CE(16:5(OH3)) 16 5 663.4983 0.5017 C43H67O5+CE(16:1(Ke,Ep2))-cyclo 16 1 663.4983 0.5017 C43H67O5+CE(16:1(Ke2,Ep))-cyclo 16 1 663.4983 0.5017 C43H67O5+CE(16:2(Ep,OO))-cyclo 16 2 663.4983 0.5017 C43H67O5+CE(16:2(Ke,OO))-cyclo 16 2 663.4983 0.5017 C43H67O5+CE(16:2(OH,Ep2))-cyclo 16 2 663.4983 0.5017 C43H67O5+CE(16:2(OH,Ke,Ep))-cyclo 16 2 663.4983 0.5017 C43H67O5+CE(16:2(OH,Ke2))-cyclo 16 2 663.4983 0.5017 C43H67O5+CE(16:3(OOH,Ep))-cyclo 16 3 663.4983 0.5017 C43H67O5+CE(16:3(OOH,Ke))-cyclo 16 3 663.4983 0.5017 C43H67O5+CE(16:3(OH,OO))-cyclo 16 3 663.4983 0.5017 C43H67O5+CE(16:3(OH2,Ep))-cyclo 16 3 663.4983 0.5017 C43H67O5+CE(16:3(OH2,Ke))-cyclo 16 3 663.4983 0.5017 C43H67O5+CE(16:4(OH,OOH))-cyclo 16 4 663.4983 0.5017 C43H67O5+CE(16:4(OH3))-cyclo 16 4 663.4983 0.5017 C43H67O5+

Page 9: Multiple Stage Tandem Mass Spectrometry for identification of plastic contaminations in blood plasma using nano electrospray ionization Tobias Kind and

Solutions – well Plasma – well Lipids!

CE(18:2(Ep)) 18 2 663.5711 0.4289 C45H75O3+CE(18:2(Ke)) 18 2 663.5711 0.4289 C45H75O3+CE(18:3(OH)) 18 3 663.5711 0.4289 C45H75O3+CE(18:1(Ep))-cyclo 18 1 663.5711 0.4289 C45H75O3+CE(18:1(Ke))-cyclo 18 1 663.5711 0.4289 C45H75O3+CE(18:2(OH))-cyclo 18 2 663.5711 0.4289 C45H75O3+

Sphingosine CerP 18:1 644.5013 0.5013 C36H71NO6P+Sphingosine HexCer 12:0 644.5096 0.5096 C36H70NO8+Sphinganine Cer 24:4 644.5976 0.5976 C42H78NO3+

Problem: Our mass accuracy is 0.046 Da but the solutions are 0.5 Da difference

Without Google Scholar we would be lost to search single m/z valuesor numbers. Still its a horrible way to do mass spectral library search.Has anybody a Google API example?

Page 10: Multiple Stage Tandem Mass Spectrometry for identification of plastic contaminations in blood plasma using nano electrospray ionization Tobias Kind and

Solutions – well Plasma – well Google It!

On the lipid composition of human meibum and tears: Comparative analysis of nonpolar lipidsIgor A. Butovich http://www.iovs.org/cgi/content/abstract/iovs.08-1889v1

Researcher working with tears = The Dacriologist (Book by Djerassi)Dakryology, the neologism for the science of tears10.1007/BF00137944also CRYING: The Natural and Cultural History of Tears By Tom Lutz Norton

"However, rushing to this conclusion would have been a mistake because subsequent fragmentation of ion m/z 663 in sequential MSn experiments gave us the following chain of product ions differing by 56 amu: 663 (MS1) -> 607 (MS2) -> 551 (MS3) -> 495 (MS4) -> 439 (MS5) -> 383 (MS6) -> 327 (MS7) (not shown). Note that the first four ions (663, 607, 551, 495) were also easily detectable in a simple MS1 experiment (Fig. 11A) . These transformations were indicative of a sequential loss of several up to six) t-butyl groups and were formerly described for oxidized form of Irgafos 168 (C42H63O4P, Fig. 11A , inset) a polymer additive present in polyethylene and polypropylene and its derivatives."

Page 11: Multiple Stage Tandem Mass Spectrometry for identification of plastic contaminations in blood plasma using nano electrospray ionization Tobias Kind and

Solutions – well Plasma – well Plasticizers!

Analysis of Additives in Polyethylene with DesorptionChemical Ionization/Tandem Mass Spectrometry

S. W. CHEN and G. R. HER*Appl. Spectrosc. 47, 844-851 (1993) http://www.opticsinfobase.org/abstract.cfm?URI=as-47-6-844

Also Oxidized Naugard 524 - http://dx.doi.org/10.1016/0003-2670(95)00183-Z

Picture Source: S. W. CHEN and G. R. HER Appl. Spectrosc. 47, 844-851 (1993)

Page 12: Multiple Stage Tandem Mass Spectrometry for identification of plastic contaminations in blood plasma using nano electrospray ionization Tobias Kind and

Solution – probably Irganox / Irgafos contamination

Picture Source: Analysis of Additives in Polyethylene with DesorptionChemical Ionization/Tandem Mass SpectrometryS. W. CHEN and G. R. HER*Appl. Spectrosc. 47, 844-851 (1993) http://www.opticsinfobase.org/abstract.cfm?URI=as-47-6-844

Plasma_Pos_LowMS_60MSMS_CE45_01 #184-190 RT: 1.15-1.27 AV: 7 NL: 2.99E3T: Composite spectrum MS8 664.00,607.32,551.33,495.34,439.26,383.17,327.06

100 200 300 400 500 600m/z

0

10

20

30

40

50

60

70

80

90

100

Rel

ativ

e A

bund

ance

551

607

495

327

439

383

Our MS^8"Lipid"

Problem solved, "lipid" is oxidized plasticizer.

Page 13: Multiple Stage Tandem Mass Spectrometry for identification of plastic contaminations in blood plasma using nano electrospray ionization Tobias Kind and

Is the problem really solved?

CID 14572930

InChIKey: AZSKHRTUXHLAHS-UHFFFAOYSA-N

No, because for the formula = C42H63O4Pthe exact mass = 662.446397016.

The [M+H]+ would be 663.4542 Da and not 664.0

In this case an ultrazoom investigation orinfusion into FT-ICR-MS with resolving power50,000 to 100,000 would probably help.

MS/MS on isotopic peak, ion suppression of isobars, overlap with multiple ceramides or cholesterol and oxycholesterol species possible

Page 14: Multiple Stage Tandem Mass Spectrometry for identification of plastic contaminations in blood plasma using nano electrospray ionization Tobias Kind and

Final question – How can we avoid rediscovery (reinventing the wheel)?

• sharing experiments (free)• sharing mass spectra (free or sell)• putting publications into OA for easier searching

How can we prevent plasticizer contaminations?

• running solvent blanks with each experiment• running methods blanks with each experiment• using only (baked) glassware

Other solutions?

• library search (but compound is not in NIST)• remember the awesome power of MS/MS/MS/MS/MS/MS/MS/MS• modern iontraps are currently not used to the full extend Data Dependent • exclusion libraries for unwanted "contaminations"

See: XLS supplement from Keller, B.O.; Sui, J.; Young, A.B.; Whittal, R.M. Interferences and contaminants encountered in modern mass spectrometry.