MWS ® DESIGN FEATURES • UL Listed under Standard 183 for make or break under load. • Meets requirements of Article 604 of the National Electrical Code. • MWS components assembled with 12 AWG/10 AWG conductors rated at 20 amperes with full size ground wire. • Copper conductors are THHN insulated wire rated 90°C. • Galvanized steel exterior with integral keying for voltage and amperage. • Valox 365 constructed contact housings are approved for environmental air plenums. • Cable end supplied with 1/2" connector with locknut and 6" pre- stripped leads. • DC cable allows you to easily supply power to other system units such as j-boxes, receptacles or fixtures. DC DROP CABLE Modular Wiring System MWS, Modular Wiring Systems, provide low cost installation of branch circuit wiring for lighting and power. Using modular components that plug together, MWS can be installed in a fraction of the time of hardwiring. Plus, MWS offers the advantage of relocating fixtures and outlets in future renovations. The MWS Drop Cable (DC) supplies power to out of system units that are wall mounted or ceiling mounted. MWS Drop cables may be plugged into the last fixture cable (FC) or from a Splitter (SP) anywhere within the system. DESCRIPTION Cable Unit Standard Length Wt. Qty./Carton 5' 2.0 lbs. 12 9' 3.0 lbs. 9 11' 3.5 lbs. 8 SHIPPING DATA S Y S T E M S C E R T I F I E D Top Side 4-3/8" [112mm] 1-7/8" [47mm] 5/8" [16mm] DIMENSIONAL DATA Drop Cable (DC) Supplies power to out of system units. (Fixtures, J-boxes, etc.). Typical MWS Wiring System Application shown utilizing Drop Cable (DC). Consult MWS Installation, Application and Specification Manual for additional comprehensive system information. Extender Cable Splitter or Circuit T Extender Cable Drop Cable Junction Box or any Out of System Unit supplied by others. SYSTEM VIEW (not to scale) MWS AUTOCAD DRAFTING MWS offers AutoCAD drafting to layout MWS, providing the contractor with additional benefits. MWS design layout time is reduced. Bills of material are computer-generated guaranteeing accuracy. MWS drawing symbols and details standardized. Layouts are available on CD or e-mail. To utilize this service and for additional information, contact the MWS Sales Department (888) 487-4887. All electrical boxes, conduit, connections and switches by others. Install dust covers on unused open ends. Scale is exaggerated on fixtures and MWS system applications. ADF031851 2015-01-15 09:36:13 SAMPLE NUMBER: 27DC12/2G11 Component DC=DropCable DC Voltage 12=120V 20=208V 24=240V 27=277V 34=347V 48=480V Conductors and Size 10/2G=#10, 2 Conductors Plus Ground 10/3G=#10, 3 Conductors Plus Ground 10/4G=#10, 4 Conductors Plus Ground 12/2G=#12, 2 Conductors Plus Ground 12/3G=#12, 3 Conductors Plus Ground 12/4G=#12, 4 Conductors Plus Ground Cable Length (Feet) 05=5' 09=9' 11=11' 15=15' Options 2N=2 Neutral (1) NOTES: (1) 12/4G and 10/4G only. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. ORDERING INFORMATION Catalog # Type Date Project Comments Prepared by Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Specifications and dimensions subject to change without notice. Eaton’s Cooper Lighting Business 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com

MWS Modular Wiring System DC Drop Cable … · DC DROP CABLE Modular Wiring System MWS, Modular Wiring Systems, provide low cost installation of branch circuit wiring for lighting

Embed Size (px)

Citation preview

Page 1: MWS Modular Wiring System DC Drop Cable … · DC DROP CABLE Modular Wiring System MWS, Modular Wiring Systems, provide low cost installation of branch circuit wiring for lighting

MWS®

DESIGN FEATURES

• UL Listed under Standard 183 for make or break under load.

• Meets requirements of Article 604 of the National Electrical Code.

• MWS components assembled with 12 AWG/10 AWG conductors rated at 20 amperes with full size ground wire.

• Copper conductors are THHN insulated wire rated 90°C.

• Galvanized steel exterior with integral keying for voltage and amperage.

• Valox 365 constructed contact housings are approved for environmental air plenums.

• Cable end supplied with 1/2" connector with locknut and 6" pre-stripped leads.

• DC cable allows you to easily supply power to other system units such as j-boxes, receptacles or fixtures.

DC

DROP CABLE

Modular Wiring System

MWS, Modular Wiring Systems, provide low cost installation of branch circuit wiring for lighting and power. Using modular components that plug together, MWS can be installed in a fraction of the time of hardwiring. Plus, MWS offers the advantage of relocating fixtures and outlets in future renovations.

The MWS Drop Cable (DC) supplies power to out of system units that are wall mounted or ceiling mounted.

MWS Drop cables may be plugged into the last fixture cable (FC) or from a Splitter (SP) anywhere within the system.

DESCRIPTION

Cable Unit Standard

Length Wt. Qty./Carton

5' 2.0 lbs. 12

9' 3.0 lbs. 9

11' 3.5 lbs. 8

SHIPPING DATA

S

YSTEMS

C

E RT I F I E

D

Top

Side

4-3/8"[112mm]

1-7/8"[47mm]

5/8"[16mm]

DIMENSIONAL DATA

Drop Cable (DC)Supplies power to out of system units. (Fixtures, J-boxes, etc.).

Typical MWS Wiring System Application shown utilizing Drop Cable (DC).

Consult MWS Installation, Application and Specification Manual for additional comprehensive system information.

Extender Cable Splitter orCircuit T

Extender Cable

Drop Cable

Junction Box or any Out of System Unit supplied by others.

SYSTEM VIEW (not to scale)

MWS AUTOCAD DRAFTINGMWS offers AutoCAD drafting to layout MWS, providing the contractor with additional benefits.

MWS design layout time is reduced.

Bills of material are computer-generated guaranteeing accuracy.

MWS drawing symbols and detailsstandardized.

Layouts are available on CD or e-mail.

To utilize this service and for additionalinformation, contact the MWS Sales Department (888) 487-4887.

All electrical boxes, conduit, connections and switches by others.

Install dust covers on unused open ends.

Scale is exaggerated on fixtures and MWS system applications.

ADF0318512015-01-15 09:36:13

SAMPLE NUMBER: 2 7 D C 1 2 /2 G 1 1

ComponentDC=DropCable

DC

Voltage12=120V20=208V24=240V27=277V34=347V48=480V

Conductors and Size10/2G=#10, 2 Conductors Plus Ground10/3G=#10, 3 Conductors Plus Ground10/4G=#10, 4 Conductors Plus Ground12/2G=#12, 2 Conductors Plus Ground12/3G=#12, 3 Conductors Plus Ground12/4G=#12, 4 Conductors Plus Ground

Cable Length (Feet)05=5'09=9'11=11'15=15'

Options2N=2 Neutral (1)

NOTES: (1)12/4G and 10/4G only.Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representativefor availability and ordering information.

ORDERING INFORMATION

Catalog # Type

Date

Project

Comments

Prepared by