MXG2MX G2 Track Luminaire
Horizontal Adjustability: 358ºVertical Adjustability: 258º
4 11/16”
6 7/8”
3 3/8”2 13/16”
LED LIGHT ENGINE ■ 92 CRI & 82 CRI in 2700K, 3000K, 3500K and 4100K with 2 SDCM binning
■ 50,000 hours L70 (rated life at 70% output)
OPTICS ■ High performance 9° Narrow Spot ■ Field changeable 12° Spot, 24° Narrow Flood, 36° Flood and 50° Wide Flood
ELECTRICAL SYSTEM ■ 120V-277V 50/60Hz input ■ Class 2 power supply ■ Over voltage, over current and short circuit protection: Auto recovery
■ This product complies with IEEE C62.41 for surge endurance up to 2.5KV. Additional surge protection recommended. Damage from power surge is not covered by warranty.
DIMMINGMust specify -DIM for Phase Dimming
■ Forward/ Reverse phase dimming ■ Phase dimming in 120V only ■ Dimmable 100 - 1%
TRACK COMPATIBILITYTrack luminaire is designed for use with the following track systems:
■ Single Circuit / Single Neutral 120V ■ Two Circuit / Single Neutral 120V (No Dimming) ■ Pro-Series Two Circuit / Two Neutral 120V ■ Pro-Series Two Circuit / Two Neutral 277V ■ J-Type Single /Two Circuit 120V ■ L-Type Single / Two Circuit 120V
ACCESSORIESLuminaire will accommodate (2) accessories, accessory holder required.
LISTING/WARRANTY ■ ETL Listed to US and Canadian standards for damp locations ■ 5-Year Intense LED Limited Warranty ■ ENERGY STAR® Qualified 1
1
Notes:1. ENERGY STAR® Qualified (LO Excludes: 2700K in 92CRI and 9° NSP
optic. L1 & L2 Excludes: 92CRI & 9°NSP optic)2. Dimming available in 120V only3. 9° Narrow spot not available in L24. Snoot is integral to fixture and factory installed. Snoot’s interior is
black and compatible with accessory holder, black accessory holder recommended.
Part Number: (Example: MXG2L230W-12)
Housing Wattage CCT / CRI Driver Finish Beam Spread Adapter Options
MXG2 L0L1L2
(10 Watts)(16 Watts)(20 Watts)
27279303093535941419
(2700K / 82 CRI)(2700K / 92 CRI)(3000K / 82 CRI)(3000K / 92 CRI)(3500K / 82 CRI)(3500K / 92 CRI)(4100K / 82 CRI)(4100K / 92 CRI)
blank-DIM2
(Non-Dimming)(Phase Dimming)
WBSV
(White)(Black)(Silver)
-093
-12-24-36-50
(9° Narrow Spot)(12° Spot)(24° Narrow Flood)(36° Flood)(50° Wide Flood)
blank
-PS-PS-274
-J-L
(Intense Single / Two Circuit 120V)(Pro-Series 120V)(Pro-Series 277V)(J-Type Adapter 120V)(L-Type Adapter 120V)
-S4 (Integral 1” Snoot)
Accessories
LH47LH47WPFLMB-47PFL1-47PFL2-47PFL4-47
(Accessory Holder, Black)(Accessory Holder, White)(Hex Louver, Black)(Prismatic Spread Lens)(Linear Spread Lens)(Soft Focus Lens)
ELECTRICAL DATA
LED Light Engine System Wattage * CCT / CRI Delivered Lumens **
L0L1L2
10W16W20W
3000K / 82 CRI3000K / 82 CRI3000K / 82 CRI
950lm1350lm1700lm
* System Wattage includes driver and LED Module consumption.** Delivered lumens will vary depending on trim, CCT, CRI, optic and ceiling thickness
JOB NAME
CATALOG NUMBER
NOTES TYPE
SPECIFICATION SHEET L/M-0817:18 P-1
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2018 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
MXG2L030Report #: ILL-02112016-09 (-12) ILL-02112016-10 (-24) ILL-02112016-11 (-36) ILL-02182016-01 (-50)
0° HORIZONTAL 30° HORIZONTAL 30° VERTICAL 60° VERTICAL
D FC W L D C FC W L D C FC W L D C FC W L
MXG2L030-123000K
12° Spot
6’8’
10’12’
33318712083.2
1’ 6”1’ 11”2’ 5”2’ 11”
1’ 6”1’ 11”2’ 5”2’ 11”
6’8’
10’12’
3”4’5’6’
22512680.956.2
2’ 1”2’ 6”3’ 2”3’ 8”
1’ 5”2”
2’ 10”3’ 4”
3.0’4.0’5.0’6.0’
5’6’8’9’
30017711478.8
1’ 3”1’ 8”2’ 4”2’ 11”
2’ 10”3’ 6”4’ 5”5’ 3”
3.0’4.0’5.0’6.0’
2’2’3’4’
473253180118
1’1’ 1”1’ 3”1’ 6”
1’ 1”1’ 8”1’ 5”2’ 2”
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
MXG2L030-243000K
24° Narrow Flood
6’8’
10’12’
16492
58.940.9
2’ 5”3’ 2”
4’4’ 10”
2’ 5”3’ 2”
4’4’ 10”
6’8’
10’12’
3’4’5’6’
11162.540
27.8
3’3’ 11”4’ 10”5’ 10”
2’ 8”3’ 5”4’ 3”5’ 2”
3.0’4.0’5.0’6.0’
5’6’7’9’
14988.655.539.4
2’ 4”2’ 10”3’ 7”4’ 4”
3’ 10”4’ 11”6’ 4”7’ 5”
3.0’4.0’5.0’6.0’
2’2’3’4’
23612589.159.1
1’ 3”1’ 8”2’ 4”2’ 10”
1’ 6”2’ 3”2’ 7” 3’ 2”
MXG2L030-363000K
36° Flood
6’8’
10’12’
61.934.822.315.5
4’5’ 4”6’ 8”
8’
4’5’ 4”6’ 8”
8’
6’8’
10’12’
2’3’4’5’
47.427.617.712.2
4’ 5”5’ 8”7’ 1”8’ 6”
4’ 1”5’ 4”6’ 8”
8’
3.0’4.0’5.0’6.0’
4’5’6’7”
7241.726.918.6
3’ 2”4’ 2”5’ 2”6’ 3”
4’ 7”5’ 11”7’ 4”8’ 10”
3.0’4.0’5.0’6.0’
2’3’3’4’
96.654
33.924.1
2’ 5”3’ 1”3’ 9”4’ 7”
2’ 7”3’ 3”4’ 2”
5’
MXG2L030-503000K
50° Wide Flood
6’8’
10’12’
29.116.410.57.3
5’ 8”7’ 7”9’ 6”11’ 5”
5’ 8”7’ 7”9’ 6”11’ 5”
6’8’
10’12’
2’3’3’4’
23.313.18.35.8
5’ 1”6’ 9”8’ 7”10’ 3”
5’6’ 8”8’ 5”10’
3.0’4.0’5.0’6.0’
3’4’5’7’
35.720.112.88.9
3’ 9”5’ 1”6’ 4”7’ 7”
4’ 10”6’ 5”
8’9’ 7”
3.0’4.0’5.0’6.0’
2’3’3’4’
44.824.915.711.2
2’ 11”3’ 11”
5’5’ 9”
3’ 1”4’ 1”5’ 2”6’ 1”
APPLICATION DATA:
W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.
W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Foot candles
Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
1198392186471214630
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
588952101647179226
2996
5991
8987
11983 10°
80°
70°
60°
50°
40°
30°20°
12° Spot (-12)
567 263
1133 526
1700 789
2267 105210° 10°20° 20°
36° Flood (-36) 50° Wide Flood (-50)
1472
2944
4416
5889 10°
80°
70°
60°
50°
40°
30°20°
24° Narrow Flood (-24)
Watts: 10Lumens: 1023 LPW: 102 CCT: 3000K
Watts: 10Lumens: 1006 LPW: 101 CCT: 3000K
Watts: 10.4Lumens: 844 LPW: 81 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
22272267163254410623
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
1047103490854423382
Watts: 10Lumens: 962 LPW: 96 CCT: 3000K
80° 80°
70° 70°
60° 60°
50° 50°
40° 40°
30° 30°
CCT / CRI Multipliers: 2700K / 82 CRI (x 0.93) 2700K / 92 CRI (x 0.76) 3000K / 82 CRI (x 1.00) 3000K / 92 CRI (x 0.87) 3500K / 82 CRI (x 1.00) 3500K / 92 CRI (x 0.87) 4100K / 82 CRI (x 1.00) 4100K / 92 CRI (x 0.87)
60°30°30°
JOB NAME
CATALOG NUMBER
NOTES TYPE
SPECIFICATION SHEET L/M-0817:18 P-2
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2018 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
MXG2L130Report #: ILL-02112016-08 (-12) ILL-02112016-07 (-24) ILL-02112016-06 (-36) ILL-02182016-02 (-50)
0° HORIZONTAL 30° HORIZONTAL 30° VERTICAL 60° VERTICAL
D FC W L D C FC W L D C FC W L D C FC W L
MXG2L130-123000K
12° Spot
6’8’
10’12’
468263168117
1’ 6”2’
2’ 5”2’ 11”
1’ 6”2’
2’ 5”2’ 11”
6’8’
10’12’
3’4’5’6’
31917911579.7
2’ 1”2’ 6”3’ 2”3’ 9”
1’ 5”2’
2’ 10”3’ 4”
3.0’4.0’5.0’6.0’
5’6’8’9’
422252160112
1’ 3”1’ 8”2’ 4”2’ 11”
2’ 10”3’ 6”4’ 5”5’ 3”
3.0’4.0’5.0’6.0’
2’2’3’4’
672359253168
1’ 1”1’ 1”1’ 3”1’ 6”
1’ 1”1’ 8”1’ 5”2’ 2”
MXG2L130-243000K
24° Narrow Flood
6’8’
10’12’
22912982.357.1
2’ 6”3’ 4”4’ 1”4’ 11”
2’ 6”3’ 4”4’ 1”4’ 11”
6’8’
10’12’
3’4’5’6’
15788.356.539.2
3’4’
4’ 11”5’ 11”
2’ 8”3’ 6”4’ 5”5’ 3”
3.0’4.0’5.0’6.0’
4’6’7’9’
21112578.855.6
2’ 4”2’ 11”3’ 8”4’ 5”
3’ 11”5’
6’ 4”7’ 6”
3.0’4.0’5.0’6.0’
2’2’3’4’
33417712583.5
1’ 4”1’ 8”2’ 5”2’ 11”
1’ 6”2’ 3”2’ 8” 3’ 2”
MXG2L130-363000K
36° Flood
6’8’
10’12’
84.347.430.421.1
4’ 2”5’ 6”6’ 11”8’ 4”
4’ 2”5’ 6”6’ 11”8’ 4”
6’8’
10’12’
2’3’4’5’
6235.822.915.8
4’ 5”5’ 9”7’ 2”8’ 8”
4’ 2”5’ 5”6’ 9”8’ 2”
3.0’4.0’5.0’6.0’
4’5’6’7”
93.154
34.824.2
3’ 2”4’ 3”5’ 3”6’ 4”
4’ 8”6’
7’ 5”8’ 11”
3.0’4.0’5.0’6.0’
2’3’3’4’
12869.845.932
2’ 5”3’ 1”3’ 8”4’ 7”
2’ 7”3’ 4”4’ 1”
5’
MXG2L130-503000K
50° Wide Flood
6’8’
10’12’
41.323.214.910.3
5’ 7”7’ 6”9’ 4”11’ 2”
5’ 7”7’ 6”9’ 4”11’ 2”
6’8’
10’12’
2’3’3’4’
33.418.411.98.3
5’ 1”6’ 10”8’ 6”10’ 2”
5’6’ 11”8’ 5”10’ 1”
3.0’4.0’5.0’6.0’
3’4’5’6’
51.629
18.612.9
3’ 8”5”
6’ 4”7’ 7”
4’ 9”6’ 4”
7’ 10”9’ 5”
3.0’4.0’5.0’6.0’
2’3’3’4’
63.835.122.515.9
3’3’ 11”
5’5’ 9”
3’ 1”4’ 2”5’ 2”6’ 2”
APPLICATION DATA:
W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.
W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Foot candles
Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
16844131569061706542
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
823073902426273328
4211
8422
12633
16844 10°
80°
70°
60°
50°
40°
30°20°
12° Spot (-12)
759 374
1518 743
2277 1122
3036 149610° 10°20° 20°
36° Flood (-36) 50° Wide Flood (-50)
2064
4129
6193
8257 10°
80°
70°
60°
50°
40°
30°20°
24° Narrow Flood (-24)
Watts: 15.5Lumens: 1484 LPW: 96 CCT: 3000K
Watts: 15.5Lumens: 1377 LPW: 89 CCT: 3000K
Watts: 15.5Lumens: 1204 LPW: 78 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
30362964216176517536
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
148514861313765330118
Watts: 15.5Lumens: 1361 LPW: 88 CCT: 3000K
80° 80°
70° 70°
60° 60°
50° 50°
40° 40°
30° 30°
CCT / CRI Multipliers: 2700K / 82 CRI (x 0.93) 2700K / 92 CRI (x 0.76) 3000K / 82 CRI (x 1.00) 3000K / 92 CRI (x 0.87) 3500K / 82 CRI (x 1.00) 3500K / 92 CRI (x 0.87) 4100K / 82 CRI (x 1.00) 4100K / 92 CRI (x 0.87)
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
60°30°30°
JOB NAME
CATALOG NUMBER
NOTES TYPE
SPECIFICATION SHEET L/M-0817:18 P-3
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2018 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.
MXG2L230Report #: ILL-02032016-05 (-12) ILL-02112016-02 (-24) ILL-02112016-03 (-36) ILL-02162016-04 (-50)
0° HORIZONTAL 30° HORIZONTAL 30° VERTICAL 60° VERTICAL
D FC W L D C FC W L D C FC W L D C FC W L
MXG2L230-123000K
12° Spot
6’8’
10’12’
613345221153
1’ 5”2’
2’ 6”3’ 1”
1’ 5”2’
2’ 6”3’ 1”
6’8’
10’12’
3’4’5’6’
427240154107
2’ 1”2’ 7”3’ 5”
4’
1’ 6”2’ 3”2’ 11”3’ 6”
3.0’4.0’5.0’6.0’
5’6’8’9’
564338214150
1’ 4”1’ 11”2’ 6”
3’
3’3’ 8”4’ 8”5’ 7”
3.0’4.0’5.0’6.0’
2’2’3’4’
900480338225
1’1’ 1”1’ 4”1’ 7”
1’ 1”1’ 9”1’ 7”2’ 3”
MXG2L230-243000K
24° Narrow Flood
6’8’
10’12’
27615599.268.9
2’ 6”3’ 4”4’ 1”4’ 11”
2’ 6”3’ 4”4’ 1”4’ 11”
6’8’
10’12’
3’4’5’6’
18810667.847.1
3’4’
4’ 11”6’
2’ 9”3’ 6”4’ 5”5’ 3”
3.0’4.0’5.0’6.0’
4’6’7’9’
25315094.866.8
2’ 5”2’ 11”3’ 8”4’ 5”
3’ 11”5’ 1”6’ 4”7’ 6”
3.0’4.0’5.0’6.0’
2’2’3’4’
401212150100
1’ 4”1’ 8”2’ 5”2’ 11”
1’ 6”2’ 3”2’ 8” 3’ 3”
MXG2L230-363000K
36° Flood
6’8’
10’12’
10357.837
25.7
4’ 1”5’ 6”6’ 11”8’ 4”
4’ 1”5’ 6”6’ 11”8’ 4”
6’8’
10’12’
2’3’4’5’
77.544.628.519.6
4’ 5”5’ 9”7’ 2”8’ 8”
4’ 1”5’ 5”6’ 9”8’ 1”
3.0’4.0’5.0’6.0’
4’5’6’7’
11667.343.530.2
3’ 2”4’ 2”5’ 3”6’ 3”
4’ 7”5’ 11”7’ 4”8’ 10”
3.0’4.0’5.0’6.0’
2’3’3’4’
15786.756.139.3
2’ 5”3’ 1”3’ 8”4’ 7”
2’ 8”3’ 4”4’ 2”
5’
MXG2L230-503000K
50° Wide Flood
6’8’
10’12’
51.929.218.713
5’ 7”7’ 5”9’ 4”11’ 2”
5’ 7”7’ 5”9’ 4”11’ 2”
6’8’
10’12’
2’3’4’4’
43.124
15.49.7
5’ 1”6’ 10”8’ 6”10’ 1”
5’6’ 8”8’ 4”9’ 11”
3.0’4.0’5.0’6.0’
3’4’5’7’
65.837
23.716.5
3’ 8”5’ 1”6’ 4”7’ 7”
4’ 10”6’ 5”7’ 11”9’ 6”
3.0’4.0’5.0’6.0’
2’3’4’4’
81.545.828.820.4
3’3’ 11”
5’5’ 10”
3’ 2”4’ 2”5’ 2”6’ 2”
APPLICATION DATA:
W and L are the outer points where the candle power drops to 50% of maximum. FC are the initial foot candles at the center of the beam.
W Beam widthL Beam lengthC Distance to center of beamD DistanceFC Foot candles
Illuminated width & length are based upon point at which illuminance falls to 50% of center illuminance. Recommended spacing is based upon uniform illuminance aiming angle is the angle between the lamp axis and the perpendicular to the illuminated plane.
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
22052183608681686842
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
9923888729553224110
5622
11245
16867
22489 10°
80°
70°
60°
50°
40°
30°20°
12° Spot (-12)
927 479
1855 957
2782 1436
3709 191510° 10°20° 20°
36° Flood (-36) 50° Wide Flood (-50)
2485
4970
7454
9939 10°
80°
70°
60°
50°
40°
30°20°
24° Narrow Flood (-24)
Watts: 20.6Lumens: 1801 LPW: 87 CCT: 3000K
Watts: 20.6Lumens: 1673 LPW: 81 CCT: 3000K
Watts: 20.3Lumens: 1539 LPW: 76 CCT: 3000K
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
36993654266992519342
Candelas at Nadir
Degree Candela
0°5°15°25°35°45°
186719151675987404149
Watts: 20.4Lumens: 1820 LPW: 89 CCT: 3000K
80° 80°
70° 70°
60° 60°
50° 50°
40° 40°
30° 30°
CCT / CRI Multipliers: 2700K / 82 CRI (x 0.93) 2700K / 92 CRI (x 0.76) 3000K / 82 CRI (x 1.00) 3000K / 92 CRI (x 0.87) 3500K / 82 CRI (x 1.00) 3500K / 92 CRI (x 0.87) 4100K / 82 CRI (x 1.00) 4100K / 92 CRI (x 0.87)
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
WL
FC
D
FC
D
LC W
L
W
D
C
D
L
W
C
L
W
CD
60°30°30°
JOB NAME
CATALOG NUMBER
NOTES TYPE
SPECIFICATION SHEET L/M-0817:18 P-4
INTENSE LIGHTING | 3340 E La Palma Ave, Anaheim, CA 92806 | tel 714 630-9877 | fax 714 630-9883For Intense Lighting’s limited product warranty, go to www.intenselighting.com. For a printed copy of the warranty, you may call 800 961-5321.© 2018 Intense Lighting, LLC. All rights reserved. Note: This document is subject to change without notice.