Product Range of application Your advantages
The multisensor suction smokedetector Helios TDS is a detectionsystem for earliest fire detection.Helios TDS is an intelligent firedetector with highest sensitivity. It detects smallest concentrations of thermal decomposition productsin the sucked air reliably and nuisance-safe.
The optionally available fire gasdetector GMX1002 CO belongs to a new generation of fire detectorsfor an even more reliable earlydetection of burgeoning fires. For the first time – developed byMinimax – there is a fire detectorfor the detection of smoulderingfires available, which reacts on carbon monoxide.
Four alarm relays and one mal-function relay with one floatingchangeover contact each facilitateconnection to any fire detectionsystem.Together with the Minimax firedetection control panels, singledetector identification can be realized via MxLoop® ring bus technology.
Multisensor suction smoke detectorHelios TDS is especially suitable formonitoring air conditioned roomsand other areas, where a reliableearly detection is required:
- information and communication technologies
- electronic and electrical systems- high-quality production systems- clean and super-clean rooms- medical areas- control rooms- suspended ceilings- false floors- cable ducts - cultural assets
Immediate detection due to a highly sensitive sensor system
High reliability due to new analysis algorithms
Optical measuring chamber with laser technology
Simultaneous two-channel measurement
Multisensor system with optionalgas detector GMX1002 CO
Sensitivity starting at 0,005 %/msubdueing of light and 5 ppm CO
Permanent air flow supervision
Automatic adjustment to ambient conditions
Intelligent function with 6 sensitivity steps
Functional status display
Multisensor suction smoke detectorHelios TDS
Safe for certain.
FIRE DETECTION SYSTEMS
FIRE DETECTORS
VdS
The air flow is measured with a volume flow sensor andcompared to the adjusted setpoint value. Deviations(pipe break or choking) of ±10% can already be reliablydetected and release an alarm.
The detector measures the laser light scattering causedby thermal decomposition products at two differentangles and thus, it ensures nuisance-safe detection of burgeoning fires. Four alarm thresholds can be pro-grammed for the entire measuring range, so that Helioscan be individually adjusted to the basic particle load inthe monitoring room.
PB33
eF_0
1/02
.03/
OPH
Prin
ted
in G
erm
any
Technical data
VdSCertfied acc. toISO 9001
★N
r. S
892
01
350
300
250
200
150
100
50
1
Main alarm
Smo
ke /
Gas
den
sity
Alarm thresholdconventional smoke detector
Info alarm
Time
Multi suction smoke detectorHELIOS TDS
Radiation trapLens
Smoke particle
Intake hole
Lens Laser
Air flow
Signalprocessor
Smoke concentrationparticle size
Backward scatter
Forwardscatter
Minimax GmbHIndustriestrasse 10/12 D-23840 Bad OldesloePhone: +49 (0) 45 31 8 03-0 Fax: +49 (0) 45 31 8 03-2 48E-mail: [email protected]
Subject to technical alterations
Function
Multisensor suction smoke detector Helios TDS uses an optical two-channel laser measuring system for qualitative and quantitative smoke particle analysis(twin-detection system). Optionally a CO fire gas detec-tor can be used depending on the monitored fire load.Air probes of the monitored area are sucked via a pipework and supplied to the optical measuring chamber and optionally to the CO fire gas detector of the Helios TDS.
Supply voltage: Nominal voltage: 24 V DC (min. 19.5 V, max. 31 V)
Power consumption: 230 mA (standby)
Ambient conditions: Temperature range:-5 °C to +50 °C (for a short time 55 °C)relative air humidity 96 %, (condensation must be excluded)
Storage: -10 °C to +65 °C,
Weight: 6.1 kg
Dimensions: 546 x 267 x 71 mm (W x H x D)
Noise generation: 49 dB (1 m distance)
Optical system: Infrared diode laser, 785 nm, 2 mW, in double circuit scattered light detection system. Laser class 3A, service life > 15 Jahre
Gas detection system: 1 slot for an optional fire gas detector module (CO), Enhanced multi sensor system analysis (= 3 detection thresholds plus gas alarm threshold)
Detector sensitivity: Detection sensitivity: 0.005 %/m Relative dynamic detection area: 0.005 %/m to 1 %/m
Connections: 24 V power supply4 floating alarm centre-zero relays (max. 30 V / 1 A DC) 1 floating malfunction centre-zero relay (max. 30 V / 1 A DC)1 detector line connection (autom. 9 V line, 2 alarm thresholds, for Minimax fire detection control panel) 1 ring main connection (MxLoop®: 2 alarms + alarm indication are addressable),1 RS232 interface (9-Pol SubD)
Measuring memory: 5,760 entries as ring memory. (volatile memory, RAM)Measured values of the ambient level and system status information
Event memory: 1,010 entries as ring memory (non-volatile memory, EEPROM)Malfunctions, alarms and maintenance information with date and time
Air flow system: Suction pipe: max. system length 100 m, (max. 35 m as single range pipe), up to 1,000 m2 monitoring area. Pipe diameter: typ. 25 mm. Number of aspirating sections: min. 10 to max. 25. Aspirating section diameter: approx. 3 mm. Air flow supervision: programmable sensitivity adjustment. Fan power consumption: 5 W
VdS approval: (Helios: G295044, Helios TDS: pending)