24
MX6 iBrid Multi-Gas Monitor

MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

Embed Size (px)

Citation preview

Page 1: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

MX6 iBridMulti-Gas Monitor

Page 2: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

What is the MX6?

• Next generation of Multi-gas instrument

• Hybrid of operating modes and sensing technologies– Diffusion or aspirated operation– Electrochemical, Catalytic diffusion,

PID, IR gas sensing

• Designed like common products for common, everyday users

Page 3: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

One Instrument, two models

• Diffusion

• Aspirated– 250cc/min flow rate

– 100 ft. sample draw

Page 4: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

MX6 vital statistics

• Diffusion model– 135mm X 77mm X 43mm

(5.3in X 3.05in X 1.7in) – 409 grams (14.4 ounces)

• Pump model– 167mm x 77mm x 56mm

(6.6in X 3.05in x 2.2in) – 511 grams (18 ounces)

• Translucent Lexan w/black rubber overmold

• Stainless steel faceplate

Page 5: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

A walk around the MX6Sensor Openings(Filters Beneath)

Sensor Filter(BeneathSensor

Openings)

Chassis

Wrist StrapConnector

(Not Shown)

Battery Charging Contacts (Not Shown)

IR Communications Port (Not Shown)

5-WayNavigation

Button

LCD

Visual Alarm(Beneath Sensor

Openings)

Page 6: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

What does MX6 detect?

• 1 to six gases

• 25 different sensors– CO, H2S, SO2, NO2, Cl2, H2, NO,

HCN, HCl, NH3, ClO2, ETO, PH3, CO2(IR), CH4(IR), LEL(IR), VOCs(PID), LEL(CB), CO/H2S, CO/H2null

• 6-gas requires CO/H2S sensor

Page 7: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

MX6 power

• Lithium-ion rechargeable

– 24 hours

• Extended range Li-ion

– 36 hours

• 3-AA Alkaline

– 10.5 hours

Page 8: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

MX6 Alarms

• Audible – 95dB

• Visual – 4 ultrabright red LEDs

• Vibrating

• All alarms are user configurable

Page 9: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

What makes the MX6 unique?

• Only gas monitor with full-color graphic liquid crystal display

Page 10: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

What makes the MX6 unique?

• Only gas monitor with graphic, menu-driven operating system

Page 11: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

What makes the MX6 unique?

• Five-way navigation button

Up

Down

RightLeft

Enter

Page 12: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

What makes the MX6 unique?

• “Bump” test mode– User sets parameters– Instrument determines Pass or Fail– Runs on start-up or user command– Displays results following test– Failed bump automatically

prompts calibration

Page 13: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

What makes the MX6 unique?

• On-board sensor calibration trends– Graphically displays sensor conditions

over last 12 calibrations

Page 14: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

What makes the MX6 unique?

• Only gas monitor with real-time, color graphic display mode

• 90 second reading window

Page 15: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

MX6 datalogging

• On-board data logging– Minimum 1-year of data at 1-minute

intervals– User/site and comment text input

• On-board graphic data review

• Event logging– Stores last 15 alarm events

Page 16: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

Other MX6 features

• Built-in sensor response factors– 115 PID factors– 20 LEL correlation factors

Page 17: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

The MX6 is international

• 8 user selectable languages built-in– English– French– Spanish– Italian– German– Dutch– Portuguese– Indonesian Bahasa

• Russian and Polish available

Page 18: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

MX6 user configuration

• User configuration mode• Password protected• Allows set-up of

– Alarms– Calibration parameters– Start-up menus– Language– Datalogging

Page 19: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

MX6 ordering information

• MX6-K1230101– O2,LEL,CO,H2S, diffusion, standard

battery, English

• List price - $1760.00USD

• Part number matrix includes– Sensors, battery, pump, language

Page 20: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

What comes with the MX6?• Instrument• Universal charger• Belt clip (installed)• Nylon carrying case• Instruction manual (in language of instrument)• Quick-start guide (in language of instrument)• Maintenance tool• CD – Training video, User’s manual• Calibration cup and tubing• Sample tubing (aspirated)• Calibration fitting (aspirated)• Dust filter/water stop

Page 21: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

MX6 accessories

• Leather cases

• Charger/Datalink

• 12-volt vehicle charger

• 5-unit charger

Page 22: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

Dock it…and walk away!

• MX6 is fully compatible with DS2 Docking Station, Ver 5.0

• Dock both diffusion and pump models

• Automatic calibration, bump test, charging, diagnostics, record keeping

• iNet ready out the door

Page 23: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

It’s SPECTACULAR!

It’s FUN TO DRIVE!

The MX6 iBrid

Its RUGGED!

It’s RELIABLE!

It’s VERSATILE!

It’s NEW!

It’s COLORFUL!

It’s INTUITIVE!

Page 24: MX6 iBrid Multi-Gas Monitor. What is the MX6? Next generation of Multi-gas instrument Hybrid of operating modes and sensing technologies –Diffusion or

The MX6 iBrid

It’s HERE!