149 Vertical Multi-Stage In-Line Pumps Construction Vertical multi-stage pumps with suction and delivery connections of the same diameter and arranged along the same axis (in-line). Corrosion-resistant bearing sleeves lubricated by the pumped liquid. Removal of the mechanical seal without dismantling the motor (for MXV 25-32-40-50,100 with motors exceeding 4 KW). A pump with thrust bearing and sleeve coupling for use of any standard motor with IM V1 construction. Version with frequency converter (on request) Applications For water supply systems. For clean non-explosive liquids, without solid, filamentary or abrasive matter (with adaptation of sealing materials on request). A universal pump for civil and industrial use, for pressure-boosting systems, high-pressure washing plants, irrigation, agricultural uses and sport installations. Operating conditions Temperature of liquid: from -15 °C to +110 °C. Operating environment temperature: up to 40 °C. Maximum permissible pressure in pump casing: 25 bar. (16 bar for pumps with oval flanges). Continuous duty. Motor Standard-type: 2-pole induction motor, 50 Hz (n ≈ 2900 rpm). Construction IM V1 (EN 60034-7). Motor suitable for operation with frequency converter. IE3 efficiency class for three-phase motors. Insulation class F. Protection IP 55. three-phase with rated voltage: up to 3 kW 230/400 V; from 4 kW 400/690 V. MXV 25, 32, 40, 50 MXV 65, 80, 100 Component Material Flange External jacket Suction casing Delivery casing Stainless Steel Stage casing 1.4301 EN 10088 (AISI 304) Impeller Lower cover Upper cover Spacer sleeve Pump shaft Stainless Steel 1.4305 EN 10088 (AISI 303) Plug (for MXV 50 AISI 304) Bearing sleeve Corrosion-resistant, cemented carbide Bearing in stage casing Ceramic alumina Mechanical seal ISO 3069 - KU Hard metal/Carbon/EPDM. Wear ring PPS (PTFE for MXV 40) O-rings NBR (EPDM for MXV 50) Oval Counterflanges AISI 304 (galvanized steel for MXV 50 O) Counterflanges (on request) AISI 304 (Steel Fe 430B for MXV 50) Pump with flanged ports (F). Pump with oval flange ports (O) (for MXV 25,32,40,50). Pump without motor. Pump with standard motor. Variants (to be specified when ordering) O-rings FPM. Other mechanical seal. Pump with motor of Client's choice (if available). Single-phase motor 230 V, up to 2.2 kW. Pump with support feet for horizontal installation (H1 or H2). Other voltage ratings. Frequency 60 Hz. Other variants (on request) Materials (wetted parts) All parts that come into contact with the liquid, including wet-end covers, are in chrome-nickel stainless steel AISI 304. Internal parts in contact with the liquid in chrome-nickel stainless steel, AISI 304 with pump casing and upper cover in cast iron. Direction of rotation: clockwise as seen from the motor. Component Material Pump casing Cast iron GJL 250 EN 1561 Upper cover External jacket Stage casing Stainless Steel 1.4301 EN 10088 (AISI 304) Impeller Spacer sleeve Pump shaft Stainless Steel (AISI 303)(AISI 431 for MXV 100) Plug Stainless Steel (AISI 303)(AISI 304 for MXV 100) Bearing sleeve Corrosion-resistant, cemented carbide Bearing in stage casing Ceramic alumina (Corrosion-resistant, cemented carbide for MXV 100) Mechanical seal ISO 3069 - KU Hard metal/Carbon/EPDM Wear ring PTFE O-rings NBR (EPDM for MXV 100) Counterflanges Steel 1.0044 EN 10025-2 (Fe 430B) (on request) Materials (wetted parts) Pump without motor. Pump with standard motor. Variants (to be specified when ordering) O-rings FPM. Other mechanical seal. Pump with motor of Client's choice (if available). Other voltage ratings. Frequency 60 Hz. Pump with support feet for horizontal installation (H1 or H2) MXV 100 series excluded. Other variants (on request) The electropumps MXV series comply with the European Regulation no. 547/2012. Direction of rotation: anticlockwise as seen from the motor. (clockwise as seen from the motor for MXV 100) MXV

MXV 07/2021 - calpeda.com

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

149

Vertical Multi-Stage In-Line Pumps

ConstructionVertical multi-stage pumps with suction and delivery connectionsof the same diameter and arranged along the same axis (in-line).Corrosion-resistant bearing sleeves lubricated by the pumped liquid.Removal of the mechanical seal without dismantling the motor(for MXV 25-32-40-50,100 with motors exceeding 4 KW).A pump with thrust bearing and sleeve coupling for use of anystandard motor with IM V1 construction.

Version with frequency converter (on request)

ApplicationsFor water supply systems.For clean non-explosive liquids, without solid, filamentary orabrasive matter (with adaptation of sealing materials on request).A universal pump for civil and industrial use, for pressure-boostingsystems, high-pressure washing plants, irrigation, agriculturaluses and sport installations.

Operating conditionsTemperature of liquid: from -15 °C to +110 °C.Operating environment temperature: up to 40 °C.Maximum permissible pressure in pump casing: 25 bar. (16 bar for pumps with oval flanges).Continuous duty.

MotorStandard-type: 2-pole induction motor, 50 Hz (n ≈ 2900 rpm).Construction IM V1 (EN 60034-7).Motor suitable for operation with frequency converter.IE3 efficiency class for three-phase motors.Insulation class F. Protection IP 55.three-phase with rated voltage: up to 3 kW 230/400 V;

from 4 kW 400/690 V.

MXV 25, 32, 40, 50 MXV 65, 80, 100

Component Material

FlangeExternal jacketSuction casingDelivery casing Stainless SteelStage casing 1.4301 EN 10088 (AISI 304)ImpellerLower coverUpper coverSpacer sleevePump shaft Stainless Steel 1.4305 EN 10088 (AISI 303)Plug (for MXV 50 AISI 304)Bearing sleeve Corrosion-resistant, cemented carbideBearing in stage casing Ceramic aluminaMechanical seal ISO 3069 - KU Hard metal/Carbon/EPDM.

Wear ring PPS (PTFE for MXV 40)O-rings NBR (EPDM for MXV 50)Oval Counterflanges AISI 304 (galvanized steel for MXV 50 O)Counterflanges (on request) AISI 304 (Steel Fe 430B for MXV 50)

Pump with flanged ports (F).Pump with oval flange ports (O) (for MXV 25,32,40,50).Pump without motor.Pump with standard motor.

Variants (to be specified when ordering)

O-rings FPM. Other mechanical seal.Pump with motor of Client's choice (if available).Single-phase motor 230 V, up to 2.2 kW.Pump with support feet for horizontal installation (H1 or H2).Other voltage ratings. Frequency 60 Hz.

Other variants (on request)

Materials (wetted parts)

All parts that come into contact with the liquid, including wet-endcovers, are in chrome-nickel stainless steel AISI 304.

Internal parts in contact with the liquid in chrome-nickel stainless steel,AISI 304 with pump casing and upper cover in cast iron.

Direction of rotation: clockwise as seen from the motor.

Component Material

Pump casing Cast iron GJL 250 EN 1561Upper cover

External jacketStage casing Stainless Steel 1.4301 EN 10088 (AISI 304)ImpellerSpacer sleevePump shaft Stainless Steel (AISI 303)(AISI 431 for MXV 100)Plug Stainless Steel (AISI 303)(AISI 304 for MXV 100)Bearing sleeve Corrosion-resistant, cemented carbideBearing in stage casing Ceramic alumina

(Corrosion-resistant, cemented carbide for MXV 100)Mechanical sealISO 3069 - KU

Hard metal/Carbon/EPDM

Wear ring PTFEO-rings NBR (EPDM for MXV 100)Counterflanges Steel 1.0044 EN 10025-2 (Fe 430B)(on request)

Materials (wetted parts)

Pump without motor.Pump with standard motor.

Variants (to be specified when ordering)

O-rings FPM. Other mechanical seal.Pump with motor of Client's choice (if available).Other voltage ratings. Frequency 60 Hz. Pump with support feet for horizontal installation (H1 or H2) MXV 100series excluded.

Other variants (on request)

The electropumps MXV series comply with the European Regulation no. 547/2012.

Direction of rotation: anticlockwise as seen from the motor.(clockwise as seen from the motor for MXV 100)

MXV

giovanni
Font monospazio
07/2021

150

MXV EI Vertical Multi-Stage In-Line Pumps

Pumps with frequency converter

The MXV EI pumps are available with power from 0,75 kW up to 22 kW, thepumps are equipped with I-MAT installed on board which allows to realize avariable-speed system extremely compact and efficient, ideal in applications ofwater supply and in the distribution of hot and cold water. The pump is equipped with transducers suitable for operation and is alreadyprogrammed at the factory.

Advantages- Energy saving- Compact design- Easy to use- Programmable to suit the system requirements- Reliability

CostructionThe system comprises of:- Pump- Induction motor- I-MAT Frequency converter- Motor adapter for the motor mounting of the frequency converter- Connection cable between frequency converter and induction motor- Transducers

Main featuresRated motor power output from 0,75 kW to 22 kWControl range from 1750 to 2900 rpm (2-pole) Protection against dry runningProtection against operations with closed connection portsProtection against system leakagesProtection against overcurrent in the motorProtection agains overvoltage and undervoltage of the power supplyProtection against current unbalances between phases

Mode at a constant pressurewith pressure sensor

In this mode, the system maintains the preset pressure when the flow required bythe installation changes.

Proportional pressure mode with pressure sensor

In this mode the system changes the working pressure according to the requiredflow rate.

Constant flow mode with flow meter

In this mode the system maintains a constant flow rate value in a point of theinstallation according to the required pressure.

Fixed speed mode with setting of the speed preferential rotation.

In this mode, by changing the working frequency, you may choose any operationalcurve included within the working range.

Constant temperature modewith temperature transducerIn this mode the system keeps the temperature constant inside a system bychanging the speed of the pump.

Operating modesH

Q

H

Q

H

Q

H

max

min

+-

+-

+ -

+-

151

MXV Vertical Multi-Stage In-Line Pumps

DesignationMXV L EI 25 - 3 05 F H1 *

Series

AISI 316L vesion(no code = AISI 304 vesion)

With frequency converter I-MAT

DN ports in mm

Rated capacity in m3/h (n ≈ 2900 rpm)

Number of stages

Construction variants

flanged ports F

oval flange ports (only for MXV(L) 25,32,40,50) O

with support feet for horizontal installation H, variant 1

with motor (or without motor)

* with no further designation = with standard motor

4.93.213/1

4.93.213/2 4.93.213/3 4.93.213/4

Numero stadi

Grandezza pompaMXV

Corpi stadio con

cuscinetto

Parti variabili

InstallazioniVarianti

Installazione verticale (Standard).

Installazione orizzontale.Flange Ovalisolo per 25,32,40,50

Flange Tonde Variante H1: aspirazione a sinistra, mandata a destra.

Variante H2: aspirazione a destra, mandata a sinistra.

Numero stadi

Grandezza pompaMXV

Corpi stadio con

cuscinetto

Parti variabili

4567810

25-30425-30525-30625-30725-30825-310

25-312

25-314

25-31625-318

25-320

40-91740-919

32-512

32-514

32-51632-518

40-911

40-913

40-915

32-50432-50532-50632-50732-50832-510

40-90440-90540-90640-90740-90840-910

111111

2222222

333

11121314151618

171920

12345678

65-320865-320965-3210

65-3212

65-320265-320365-320465-320565-320665-3207

50-150150-150250-150350-150450-150550-150650-150750-1508

50-150950-151050-151150-151250-1513

50-151450-151550-151650-1517

50-200150-200250-200350-200450-200550-200650-200750-2008

50-200950-201050-201150-201250-2013

50-201450-201550-201650-2017

80-480680-480780-4808

80-480180-480280-480380-480480-4805

11111111

22222222

3333

678910111213

14151617

Variable parts

Variants Installations

Variable parts

Horizontal installation.

Vertical installation(Standard).

Pump with Oval flange portsonly for 25,32,40,50

Pump with flanged ports

Pump sizeMXV

Number of stages

Variant H1: suction on the left, delivery on the right.

Stage casings with

bearing

Pump sizeMXV

Number of stages

Stage casings with

bearing

Variant H2: suction on the right, delivery on the left.

152

Coverage chart

MXV Vertical Multi-Stage In-Line Pumps

2 4 8 3216 481 3 5 6 7 9 10 20 40 70600

50

100

150

200

250

0m /h

l/min 30 40 50 100 1000150 200

80 90100 150

1500 2000300 400 500

3

72.936/1

5 10 20 304

m

50 10040 200 300 500400Imp. g.p.m.

ft

Q

H

25-3 32-5 40-9

50-15

65-32

80-48

100-65

100-90

H

100

200

300

400

500

700

800MXVn≈ 2900 1/min

50-20

153

Characteristic curves and performance n ≈ 2900 rpm

H

Q

4

5

6

7

8

10

12

14

16

18

MXV 25-320

Q

η

η

3 72.983

3

kW

MXV 25-307

MXV 25-304

MXV 25-310

MXV 25-308

MXV 25-312MXV 25-314MXV 25-316MXV 25-318MXV 25-320

MXV 25-305MXV 25-306

HP

0,750,751,11,11,5

1,52,22,23

11

1,51,52

233444

33

445668

79,591114136159182205228

42,553

63,57485

106127149170191213

44

4,74,77,47,49,29,211,411,411,4

2,32,32,72,74,34,35,35,36,66,66,6

4050

60,570,580,5101121141161181202

37,54756

65,57594112131150169188

34,543

51,5606986

103121138155173

3139

46,554,56278

93,5109124140156

2734

40,547,55468

81,595

108122136

22,52834

39,545,55768

79,591

102114

1721253034425159687685

Hm

m /h3

l/min

1

16,6

1,5

25

2,5

41,6

3

50

3,5

58,3

4

66,6

4,5

75

2

33,3

0

0A*A*Q

0 50

0

0.1

0.2

240

0

0

0 50

2

4

0

10

20

40

60

80

100

120

140

180

200

220

1 2 3 4

1 2 3 4

0

100

200

300

400

500

600

700

5 10 15 20U.S. g.p.m.

ft

m

20 40 60 8030 50 70m /hl/min

m /h

30

50

40

Pst

ft

NPSH

m

kW

Pst

%

230 V 400 V

Vertical Multi-Stage In-Line PumpsMXV 25-3

Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012

Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosity ν= max 20 mm2/sec.

Pst = Power with reference to one stage.A* Calpeda motor currents

Pump typeMotor power

154

H

Q

45678

10

12

14

16

MXV 32-518

Q

3

72.9843

ηη

kW

0

MXV 32-507

MXV 32-504

MXV 32-510

MXV 32-508

MXV 32-512MXV 32-514MXV 32-516MXV 32-518

MXV 32-505MXV 32-506

HP

1,51,5223

344

5,55,5

1,11,11,51,52,2

2,23344

Hm

m /h3

l/min

41,551,562

72,583

104124145166187

2,5

41,6

405060

70,580,5101121141161181

3

50

36,546

55,5657493111130148167

4

66,6

34,543,552,561,57088

105123140158

4,5

75

32,541

49,5586683

99,5116132149

5

83,3

27,534,5424956708498112126

6

100

2227,533,539

44,5566778

89,5100

7

116,6

14,518,522,526,53038

45,553

60,568

8

133,3

38,548586878

97,5117136156175

3,5

58,30Q

0 90

0.05

0.25

240

0

0

0 90

2

4

0

10

20

40

60

80

100

120

140

180

200

220

0

100

200

300

400

500

600

700

ft

m

2 3 4 5 6 7 850 100 150

35

45

55

10 20 30

2 3 4 5 6 7 8

0.1

0.2

Imp. g.p.m.

m /hl/min

ft

PstkW

Pst

m /h

NPSH

m

%

4,74,77,47,49,29,211,411,4

2,72,74,34,35,35,36,66,69,69,6

A*A*

230 V 400 V

455668

79,591114136159182205

MXV 32-5

Characteristic curves and performance n ≈ 2900 rpm

Vertical Multi-Stage In-Line Pumps

Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012

Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.

Pst = Power with reference to one stage.A* Calpeda motor currents

Pump typeMotor power

155

H

Q

Q

4

5

6

7

8

10

11

13

15

17

MXV 40-919

3

3 72.392

η η

kW

MXV 40-907

MXV 40-904

MXV 40-910

MXV 40-908

MXV 40-911MXV 40-913MXV 40-915MXV 40-917MXV 40-919

MXV 40-905MXV 40-906

HP

23344

5,55,57,57,510

1,52,22,233

44

5,55,57,5

7,5 10

Hm

m /h3

l/min

43475971

8395

119131155179202

226

54657687

109119141163184

5

83,3

4253637485

106116138159180

6

100

4050596979

99109129149168

8

133,3

3747566675

94103122141159

9

150

3443516069

8694111128145

10

166,6

3038455360

758398113128

11

183,3

2632394551

64718496109

12

200

2126313642

5257687889

13

216,6

4151627282

103113134154175195201206 188 178 162 143 122 99

7

116,6

0

0Q

0 140

0

0.2

0.4

240

0

0

00

2

4

0

10

20

40

60

80

100

120

140

180

200

220

0

100

200

300

400

500

600

700

ft

m

50

70

60

ft

2 4 6 8 10 12

10 20 30 40 50Imp. g.p.m.

50 100 150 200

142 4 6 8 10 12

m /hl/min

m /h

Pst

m

NPSH

%

Pst

kW

7,49,29,211,411,4

4,35,35,36,66,69,69,610,910,914,314,3

A*A*

230 V 400 V

MXV 40-9

Characteristic curves and performance n ≈ 2900 rpm

Vertical Multi-Stage In-Line Pumps

Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012

Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.

Pst = Power with reference to one stage.A* Calpeda motor currents

Pump typeMotor power

156

Characteristic curves and performance n ≈ 2900 rpm

Vertical Multi-Stage In-Line Pumps

H

Q

Q0 24

0

0.6

1.0

280

0

0

20

40

60

80

100

120

140

180

200

220

4 8 200

100

200

300

400

500

600

700

25 50 75Imp. g.p.m.

ft

m

100 200 300 400150 250 350m /h

40

80

60

Pst

kW%

0.2

240800

0 4 8

12

12

16

16 20m /h0

4

NPSH

m

8

10

0

ft

20

0

0

0 25 50 75Imp. g.p.m.

m /hl/min

24

260

900

MXV 50-1501MXV 50-1502MXV 50-1503/AMXV 50-1504MXV 50-1505MXV 50-1506MXV 50-1507MXV 50-1508/AMXV 50-1509MXV 50-1510MXV 50-1511MXV 50-1512MXV 50-1513MXV 50-1514MXV 50-1515MXV 50-1516MXV 50-1517

1,11,52,234

5,55,55,57,57,59,29,21111111515

1,5234

5,57,57,57,51010

12,512,51515152020

9,519,831,543,054,063,073,58697

105116132143154165174185

8,417,828,639,549,557,567,0788895

105121131141151159169

7,015,425,135,044,050,559,069778391

107116125134140149

5,512,721,030,037,542,549,5586569769198106113119126

10,321,433,946,057,568,079,592

104114125141153165177186198

12,024,638,652,065,078,091,5105118130143159173186199211224

14,027,943,658,072,585,099,0115129141155173188202217230245

11,623,837,350,563,075,588,0101114126138155167180193204217

11,022,735,848,560,572,084,097110121133149161173186196209

3,69,516,324,030,033,539,0455154597278849094100

2,74,35,36,69,610,910,910,914,314,318,518,521,521,521,527,327,3

4,77,49,211,4

HPkW

Hm

m /h3

l/min

8

133,3

10

166,6

14

233

16

266

18

300

20

333

22

366

24

400

12

200

0

0Q

3

3 72.937

ηη

kWA*A*

230 V 400 V

1110

9

8

7

6

5

4

3

2

1

1213

14

15

16

MXV 50-1517

Pst

MXV 50-15

Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012

Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.

Pst = Power with reference to one stage.A* Calpeda motor currents

Pump typeMotor power

H

Q

Q0 28

0

0.6

1.0

280

0

0

20

40

60

80

100

120

140

180

200

220

4 8 200

100

200

300

400

500

600

700

25 50 75Imp. g.p.m.

ft

m

100 200 300150 250 350m /h

40

80

60

Pst

kW

Pst

%

0.2

240800

0 4 8

12

12

16

16 20m /h0

4

NPSH

m

8

10

0

ft

20

0

0

0 25 50 75Imp. g.p.m.

m /hl/min

28

24

24

260

900

100

400 450

MXV 50-2001MXV 50-2002MXV 50-2003MXV 50-2004MXV 50-2005MXV 50-2006MXV 50-2007MXV 50-2008MXV 50-2009MXV 50-2010MXV 50-2011MXV 50-2012MXV 50-2013MXV 50-2014MXV 50-2015MXV 50-2016MXV 50-2017

1,12,234

5,57,57,59,29,2111115151515

18,518,5

1,534

5,57,51010

12,512,51515202020202525

10,723,335,448,561,073,085,097114127140151164177189205217

9,821,732,945,557,068,580,091

108120132143154166178193205

8,719,830,042,052,562,573,083

100111122132143154165179190

7,317,526,537,546,555,564,5748999

109118128138148161172

11,524,537,551,064,076,589,5102120133146158171185198214227

13,027,041,456,070,084,098,0112130144159172186201215232246

15,530,746,562,578,092,0

107,0122142158173188204219235251267

12,626,340,454,568,082,095,5109127141155168182196210227241

12,125,539,153,066,079,593,0106124137151164177191205221235

5,814,722,532,040,047,055,063778694103111120128140149

4,011,718,026,032,537,544,050637178849199

106116124

2,75,36,69,610,914,314,318,518,521,521,527,327,327,327,33434

4,79,211,4

HPkW

Hm

m /h3

l/min

10

166,6

14

233

16

266

18

300

20

333

22

366

24

400

26

433

28

466

12

200

0

0Q

3

3 72.937

ηη

kWA*A*

230 V 400 V

11

10

9

8

7

6

5

4

3

2

1

12

13

14

15

16

MXV 50-2017

MXV 50-20

157

Characteristic curves and performance n ≈ 2900 rpm

Vertical Multi-Stage In-Line Pumps

Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012

Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.

Pst = Power with reference to one stage.A* Calpeda motor currents

Pump typeMotor power

158

2943,558,57387

102116130145174

2740,554,56882

95,5109122136163

24,53750

62,575

87,5100112125150

2233,545

56,567,57990101112135

3046617792

107123138154185

34516986

103121138155172207

3755,575

93,5112131150168187225

3249

65,582

98,5115131148164197

3147,563,579,595,5111127143159191

1725,53544

52,561,57079

87,5105

MXV 65-3207/D

MXV 65-3204/C

MXV 65-3202/DMXV 65-3203/C

MXV 65-3209/E

MXV 65-3208/D

MXV 65-3210/EMXV 65-3212/D

MXV 65-3205/DMXV 65-3206/D

HPkW

45,57,51111

1515

18,518,5

5,57,5101515

202025253022

Hm

m /h3

l/min

15

250

21

350

27

450

30

500

33

550

36

600

39

650

44

733

24

400

0

0Q

72.9743

3

H

Q

MXV 65-3212

10

9

8

7

6

5

4

3

2

Q

0 500

1

2

240

0

0

20

40

60

80

100

120

140

180

200

220

10 20 30 400

100

200

300

400

500

600

700

50 100 150Imp. g.p.m.

ft

m

200 400 600 800300 500 700m /hl/min

40

80

60

η Pst

kW

Pst

%

η

0

10

0 5010 20 30 40m /h0

4

NPSHft

m

0

20

8

9,610,914,321,521,527,327,3343441

A*A*

230 V 400 V

MXV 65-32

Characteristic curves and performance n ≈ 2900 rpm

Vertical Multi-Stage In-Line Pumps

Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012

Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.

Pst = Power with reference to one stage.A* Calpeda motor currents

Pump typeMotor power

159

MXV 80-48

72.1035

ft

m

m /hl/min

ft

Pst

kWPst

m /h

NPSH

m

H

Q

Q

3

3

η%η

MXV 80-4801/DMXV 80-4802/CMXV 80-4803/CMXV 80-4804/DMXV 80-4805/DMXV 80-4806/DMXV 80-4807/EMXV 80-4808/D

HPkW

45,57,5111515

18,522

5,57,5101520202530

1326,54055

68,58296

109

1224,537

51,564,577,590

103

10,722344860728496

9,520314455667788

1529,544607590

105120

1836547290

108126144

2040,56181

101121142162

1734,5516986

103120137

1632,548658197113129

Hm

m /h3

l/min

21

350

27

450

33

550

45

750

48

800

51

850

54

900

715,524,5354453

61,570,5

60

1000

39

650

0

0Q

4

0

2

3

1

70

80

50

7

6

5

4

3

2

1000900

200

50

6010 30

10 30

160

ft

50

60

104

6

040200

1

60

40

MXV 80-4808

700500300 800600400200

Imp. g.p.m. 15010050

600

500

400

300

200

100

04020

180

200

140

120

100

80

60

40

20

0

0

2

0

0

9,610,914,321,527,327,33441

A*A*

230 V 400 V

Characteristic curves and performance n ≈ 2900 rpm

Vertical Multi-Stage In-Line Pumps

Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012

Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.

Pst = Power with reference to one stage.A* Calpeda motor currents

Pump typeMotor power

160

MXV 100-65

0

0

2

4

6

8

4

108

12

072.9743

3

H

Q

MXV 100-65

Q

0 1000

240

0

0

20

40

60

80

100

120

140

180

200

220

20 40 60 800

100

200

300

400

500

600

700

100 200 300Imp. g.p.m.

ft

m

400 800 1200 1600600 1000 1400m /hl/min

20

100

60

40

80% η

0 10020 40 60 80m /h

ft

kW

PstPst

Pst R

NPSH

m

8-2R

7

8

7-2R

6

6-2R

5

5-2R

4

4-2R

3

3-2R

2

1

2-2R

MXV(L) 100-6501/AMXV(L) 100-6502-2R/AMXV(L) 100-6502/AMXV(L) 100-6503-2R/AMXV(L) 100-6503/BMXV(L) 100-6504-2R/BMXV(L) 100-6504/AMXV(L) 100-6505-2R/AMXV(L) 100-6505/AMXV(L) 100-6506-2R/AMXV(L) 100-6506/AMXV(L) 100-6507-2R/AMXV(L) 100-6507/AMXV(L) 100-6508-2R/AMXV(L) 100-6508/A

HPkW

5,57,51115

18,518,5223030303737454545

7,51015202525304040405050606060

20,330,543,253,465,776,088,4

101,1114,1123,4136,5145,7160,0169,3182,3

18,325,839,947,260,768,382,392,1

106,9112,9127,8133,7149,9156,0170,7

15,420,335,339,553,958,573,380,496,399,0115,0117,7135,1137,9153,8

12,214,630,831,447,247,962,968,084,684,1100,9100,3118,9118,4135,1

21,733,845,557,669,081,192,4

107,0119,0130,3142,3153,6166,7178,1190,1

24,837,251,263,077,688,6

100,8116,2129,2141,6154,7167,0181,1193,5206,5

30,238,959,367,389,695,5111,8125,3142,4153,5170,6181,7199,5210,6227,7

23,035,848,060,672,885,196,7111,8124,0136,2148,5160,6173,8186,0198,2

22,334,846,859,170,983,294,5

109,5121,5133,3145,4157,2170,3182,2194,1

Hm

m /h3

l/min

30

500

40

666

60

1000

70

1166

80

1333

88

1466

50

833

45

750

0

0Q

10,914,321,527,33434415353536565787878

A*

400 V

η

Characteristic curves and performance n ≈ 2900 rpm

Vertical Multi-Stage In-Line Pumps

Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012

Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.

Pst = Power with reference to one stage.A* Calpeda motor currents

Pump typeMotor power

161

MXV 100-90

72.1035

ft

m

m /hl/min

ft

Pst

Pst RPst

kW

m /h

NPSH

m

H

Q

Q

3

3

η

MXV(L) 100-9001-1R/AMXV(L) 100-9001/AMXV(L) 100-9002-2R/AMXV(L) 100-9002/AMXV(L) 100-9003-2R/BMXV(L) 100-9003/AMXV(L) 100-9004-2R/AMXV(L) 100-9004/AMXV(L) 100-9005-2R/AMXV(L) 100-9005/AMXV(L) 100-9006-2R/AMXV(L) 100-9006/A

HPkW

5,57,51115

18,522303037374545

7,51015202530404050506060

15,520,433,244,357,769,483,595,7

106,9119,1131,4143,6

13,218,829,441,653,065,577,590,799,7112,8122,9136,2

9,515,722,736,344,357,866,580,886,1

100,3107,0121,3

5,712,415,730,534,949,754,670,271,687,189,8

105,5

17,321,936,647,362,273,289,0

100,6113,7125,2139,3150,9

20,527,042,456,670,882,6

100,6113,0128,4140,7157,0169,5

26,435,649,669,280,492,4113,1125,6144,1156,6175,9188,4

19,925,641,354,569,180,698,2110,4125,4137,4153,4165,6

18,723,239,050,565,676,793,5

105,2119,3130,9146,1157,8

Hm

m /h3

l/min

45

750

50

833

60

1000

80

1333

88

1466

100

1666

110

1833

3,510,511,727,330,445,248,564,464,179,880,896,7

115

1916

70

1166

0

0Q

8

10

0

4

6

2

80

100

40

20001800

400

100

12020 60

20 60

160

ft

100

120

108

12

080400

60

20

MXV 100-90

14001000600 16001200800400

Imp. g.p.m. 300200100

600

500

400

300

200

100

08040

180

200

140

120

100

80

60

40

20

0

0

4

0

0

10,914,321,527,33441535365657878

A*

400 V

6

6-2R

5-2R

4-2R

2-2R

1-1R

5

4

3

3-2R

2

1

Characteristic curves and performance n ≈ 2900 rpm

Vertical Multi-Stage In-Line Pumps

Test results with clean cold water, without gascontent.A safety margin of + 0.5 m is recommended forthe NPSH value.Tolerances in accordance with UNI EN ISO 9906:2012

Head and power values valid for liquids withdensity ρ = 1,0 kg/dm3 and kinematic viscosityν = max 20 mm2/sec.

Pst = Power with reference to one stage.A* Calpeda motor currents

Pump typeMotor power

162

MXV25-332-540-9

Dimensions and weights

Vertical Multi-Stage In-Line Pumps

ØN.

d

115140

DEDN

150

85100

DK

110

6576

DG

84

141919

444

253240

DNDGDKDE

EN 1092-1 PN 25 - 40

(5)(7)

(5)(7)

kg kg

MXV 25-304MXV 25-305MXV 25-306MXV 25-307MXV 25-308MXV 25-310MXV 25-312MXV 25-314MXV 25-316MXV 25-318MXV 25-320MXV 32-504MXV 32-505MXV 32-506MXV 32-507MXV 32-508MXV 32-510MXV 32-512MXV 32-514MXV 32-516MXV 32-518MXV 40-904MXV 40-905MXV 40-906MXV 40-907MXV 40-908MXV 40-910MXV 40-911MXV 40-913MXV 40-915MXV 40-917MXV 40-919

kW DN

mm

AD m4HP0,750,751,11,11,51,52,22,2333

1,11,11,51,52,22,23344

1,52,22,23344

5,55,57,57,5

11

1,51,52233444

1,51,5223344

5,55,523344

5,55,57,57,51010

M80 V1M80 V1M80 V1M80 V1M90 V1M90 V1M90 V1M90 V1

M100 V1M100 V1M100 V1M80 V1M80 V1M90 V1M90 V1M90 V1M90 V1

M100 V1M100 V1M112 V1M112 V1M90 V1M90 V1M90 V1

M100 V1M100 V1M112 V1M112 V1M132 V1M132 V1M132 V1M132 V1

2525252525252525252525323232323232323232324040404040404040404040

a

250250250250250250250250250250250250250250250250250250250250250280280280280280280280280280280280

127,5127,5127,5127,5127,5127,5127,5127,5137,5137,5137,5127,5127,5127,5127,5127,5127,5137,5137,5137,5137,5127,5127,5127,5137,5137,5137,5137,5159,5159,5159,5159,5

M255255255255255255295295311311311255255255255295295311311311311255295295311311311311339339339339

h1 f

7575757575757575757575757575757575757575758080808080808080808080

382,5406,5430,5454,5478,5527

575,5623,5672

720,5768,5382,5406,5430,5454,5478,5527

575,5623,5672

720,5411,5441,5471,5501,5532592622

769,5830890950

n1205205205205205205205205205205205205205205205205205205205205205250250250250250250250250250250250

n2180180180180180180180180180180180180180180180180180180180180180215215215215215215215215215215215

m1165165165165165165165165165165165165165165165165165165165165165190190190190190190190190190190190

m2100100100100100100100100100100100100100100100100100100100100100130130130130130130130130130130130

s1313131313131313131313131313131313131313131414141414141414141414

g135,535,535,535,535,535,535,535,535,535,535,535,535,535,535,535,535,535,535,535,535,530,530,530,530,530,530,530,530,530,530,530,5

fM637,5661,5685,5709,5733,5782

870,5918,5983

1031,51079,5637,5661,5685,5709,5773,5822

886,5934,5983

1031,5666,5736,5766,5812,5843903933

1108,5116912291289

P200200200200200200200200250250250200200200200200200250250250250200200200250250250250300300300300

-283307331355379

427,5476524

572,5621669283307331355379

427,5476524

572,5621312342372402

432,5492,5522,5583,5644704764

-

4.93.210/2

(6) (6)

h1

fM

M

AD

DN

DN

ag1

n1n2

m1

sm2 40

m4

200

15

f

170

129Ø15

G 3/8(3)

G 3/8(2)

G 3/8(3)

G 3/8(2)

G 1/4(1)

G 1/4(1)

G 1/4(1)

G 1/4(1)

(4)P

Pump

(1) Filling and air vent(2) Air vent suction side(3) Draining(4) Standard position of terminal box.

(for other positions rotate motor through 90° or 180°)(5) MXV (H) : + 3 kg

(6) With standard motor(7) Net weight

Motorwithoutmotor

withmotor

Flanges

Holes

163

MXV25-332-540-9

Dimensions and weights

Vertical Multi-Stage In-Line Pumps

MXV 25-304 OMXV 25-305 OMXV 25-306 OMXV 25-307 OMXV 25-308 OMXV 25-310 OMXV 25-312 OMXV 25-314 OMXV 32-504 OMXV 32-505 OMXV 32-506 OMXV 32-507 OMXV 32-508 OMXV 32-510 OMXV 32-512 OMXV 32-514 OMXV 40-904 OMXV 40-905 OMXV 40-906 OMXV 40-907 OMXV 40-908 OMXV 40-910 OMXV 40-911 OMXV 40-913 O

kW DN

mm

AD m4HP0,750,751,11,11,51,52,22,21,11,11,51,52,22,233

1,52,22,23344

5,5

11

1,51,52233

1,51,522334423344

5,55,57,5

M80 V1M80 V1M80 V1M80 V1M90 V1M90 V1M90 V1M90 V1M80 V1M80 V1M90 V1M90 V1M90 V1M90 V1

M100 V1M100 V1M90 V1M90 V1M90 V1

M100 V1M100 V1M112 V1M112 V1M132 V1

252525252525252532323232323232324040404040404040

a

160160160160160160160160160160160160160160160160200200200200200200200200

127,5127,5127,5127,5127,5127,5127,5127,5127,5127,5127,5127,5127,5127,5137,5137,5127,5127,5127,5137,5137,5137,5137,5159,5

M255255255255255255295295255255255255295295311311255295295311311311311339

h1 f

505050505050505050505050505050508080808080808080

367391415439463

511,5560608367391415439463

511,5560608

411,5441,5471,5501,5532592622

769,5

n1205205205205205205205205205205205205205205205205250250250250250250250250

n2180180180180180180180180180180180180180180180180215215215215215215215215

m1165165165165165165165165165165165165165165165165190190190190190190190190

m2100100100100100100100100100100100100100100100100130130130130130130130130

s131313131313131313131313131313131414141414141414

g120202020202020202020202020202020

30,530,530,530,530,530,530,530,5

fM622646670694718

766,5855903622646670694758

806,5871919

666,5736,5766,5812,5843903933

1108,5

P200200200200200200200200200200200200200200250250200200200250250250250300

(5)(7)

-268292316340364

412,5461509

267,5291,5315,5339,5363,5412

460,5508,5312342372402

432,5492,5522,5583,5

(5) (6)(7)

kg kg

-

ØN.1

1 1/4

GDN

1 1/2

2323

w

26

121215

222

253240

PN 16

ØN.DN9595

DE

125

7575

DK

100

M10M10M12

222

253240

PN 16

(6) (6)

4.93.210/2

h1

f

AD

M

a

fM

DN

DN

g1

n1n2

m1

sm2

DK

DE

DN

40

m4

200

15

G 3/8(3)

G 3/8(2)

170

129Ø15

G 3/8(3)

G 3/8(2)

G 1/4(1)

G 1/4(1)

G 1/4(1)

G 1/4(1)

(4)P

DN G

w

Pump

(1) Filling and air vent(2) Air vent suction side(3) Draining(4) Standard position of terminal box.

(for other positions rotate motor through 90° or 180°)(5) MXV (H) : + 3 kg

(6) With standard motor(7) Net weight

Motorwithoutmotor

withmotor

OvalCounterflanges

Oval Flanges

Holes

Holes

164

MXV 50-1550-20

Dimensions and weights

Vertical Multi-Stage In-Line Pumps

MXV 50-1501MXV 50-1502MXV 50-1503/AMXV 50-1504MXV 50-1505MXV 50-1506MXV 50-1507MXV 50-1508/AMXV 50-1509MXV 50-1510MXV 50-1511MXV 50-1512MXV 50-1513MXV 50-1514MXV 50-1515MXV 50-1516MXV 50-1517MXV 50-2001MXV 50-2002MXV 50-2003MXV 50-2004MXV 50-2005MXV 50-2006MXV 50-2007MXV 50-2008MXV 50-2009MXV 50-2010MXV 50-2011MXV 50-2012MXV 50-2013MXV 50-2014MXV 50-2015MXV 50-2016MXV 50-2017

kW DN a h1 f

mm

AD m4HP1,11,52,234

5,55,55,57,57,59,29,211111115151,12,234

5,57,57,59,29,2111115151515

18,518,5

1,5234

5,57,57,57,51010

12,512,515151520201,534

5,57,51010

12,512,51515202020202525

M80 V1M90 V1M90 V1

M100 V1M112 V1M132 V1M132 V1M132 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M80 V1M90 V1

M100 V1M112 V1M132 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1

50505050505050505050505050505050505050505050505050505050505050505050

300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300

90909090909090909090909090909090909090909090909090909090909090909090

438438486534582693741789837885963

101110591107115512031251438438486534645693741819867915963

101110591107115512031251

127,5127,5137,5137,5137,5159,5159,5159,5159,5159,5186186186186186186186

127,5127,5137,5137,5159,5159,5159,5186186186186186186186186206206

M

255255311311311339339339339339413413459459459484484255295311311339339339413413459459484484484484538538

fM

693693797845893

103210801128117612241376142415181566161416871735693733797845984

103210801232128013741422149515431591163917411789

P

200200200250250300300300300300350350350350350350350200200250250300300300350350350350350350350350350350

MXV (5)(7)

27,427,929,431,833,344,345,747,248,650,158,059,360,762,263,765,166,627,427,930,331,842,844,345,753,554,956,457,859,360,762,263,765,166,6

313313361409457505553601649697745793841889937985

1033313313361409457505553601649697745793841889937985

1033

165

DEDN

DN 50

125

DK

499

DG

1950

EN 1092-2 PN 25

(6)(7)

kgkg

40,741,255,057,461,186,688,094,996,397,8128

129,3136,7138,2139,7167,1168,640,746,055,959,685,192,093,4

123,5124,9132,4133,8161,3162,7164,2165,7187,1188,6

N. Ø

(6) (6)

4.93.210/2

h1

fM

M

AD

DN

DN

a25

250

215

196

13

130 40

m4

200

15

170

129Ø15

P

G 3/8(3)

G 3/8(2)

G 3/8(3)

G 3/8(2)

G 1/4(1)

G 1/4(1)

G 1/4(1)

G 1/4(1)

(4)

d

DN

DG

DK

DE

(1) Filling and air vent

(2) Air vent suction side

(3) Draining

(4) Standard position of terminal box. (for other positions rotate motor through 90° or 180°)

(5) (H) : + 3 kg

(6) With standard motor

(7) Net weight

Pump Motorwithoutmotor

withmotor

Flanges EN 1092-2 PN 25

Holes

165

MXV 50-1550-20

Dimensions and weights

Vertical Multi-Stage In-Line Pumps

MXV 50-1501 OMXV 50-1502 OMXV 50-1503/A OMXV 50-1504 OMXV 50-1505 OMXV 50-1506 OMXV 50-1507 OMXV 50-1508/A OMXV 50-1509 OMXV 50-1510 OMXV 50-2001 OMXV 50-2002 OMXV 50-2003 OMXV 50-2004 OMXV 50-2005 OMXV 50-2006 OMXV 50-2007 OMXV 50-2008 OMXV 50-2009 OMXV 50-2010 O

kW DN h1 f

mm

AD m4HP1,11,52,234

5,55,55,57,57,51,12,234

5,57,57,59,29,211

1,5234

5,57,57,57,510101,534

5,57,51010

12,512,515

M80 V1M90 V1M90 V1

M100 V1M112 V1M132 V1M132 V1M132 V1M132 V1M132 V1M80 V1M90 V1

M100 V1M112 V1M132 V1M132 V1M132 V1M160 V1M160 V1M160 V1

5050505050505050505050505050505050505050

a

200200200200200200200200200200200200200200200200200200200200

9090909090909090909090909090909090909090

438438486534582693741789837885438438486534645693741819867915

127,5127,5137,5137,5137,5159,5159,5159,5159,5159,5127,5127,5137,5137,5159,5159,5159,5186186186

M

255255311311311339339339339339255295311311339339339413413459

fM

6936937978458931032108011281176122469373379783298410321080123212801374

P

200200200250250300300300300300200200250250300300300350350350

MXV (5)(7)

kg kg

24,625,126,629,030,541,542,944,445,847,324,625,127,629,040,041,542,950,752,153,6

313313361409457505553601649697313313361409457505553601649697

(6)(7)

37,938,452,254,658,383,885,286,793,595,037,943,253,256,882,389,290,6

120,7122,1129,6

(6) (6)

4.93.210/2

h1

fM

f

M

AD

DN

DN

a25

250

215

196

13

130

100

130

DN 50

40

m4

200

15

N. 2 M 12

170

129Ø15

G 3/8(3)

G 3/8(2)

G 3/8(3)

G 3/8(2)

G 1/4(1)

G 1/4(1)

G 1/4(1)

G 1/4(1)

(4)

P

DN

50

G 2

34

(1) Filling and air vent

(2) Air vent suction side

(3) Draining

(4) Standard position of terminal box. (for other positions rotate motor through 90° or 180°)

(5) (H) : + 3 kg

(6) With standard motor

(7) Net weight

Oval Counterflanges

Oval Flanges

Pump Motorwithoutmotor

withmotor

166

kW DN a h1 f

mm

AD m4HP

137,5159,5159,5186186186186206206206

137,5159,5159,5186186186206206

MXV 65-3202/D MXV 65-3203/C MXV 65-3204/C MXV 65-3205/D MXV 65-3206/D MXV 65-3207/D MXV 65-3208/D MXV 65-3209/E MXV 65-3210/E MXV 65-3212/D MXV 80-4801/D MXV 80-4802/C MXV 80-4803/C MXV 80-4804/D MXV 80-4805/D MXV 80-4806/D MXV 80-4807/E MXV 80-4808/D

45,57,511111515

18,518,5224

5,57,5111515

18,522

5,57,510151520202525305,57,5101520202530

M112 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M180 V1M112 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M180 V1

656565656565656565658080808080808080

320320320320320320320320320320320320320320320320320320

105105105105105105105105105105105105105105105105105105

407473519595641687733779825917411466527618680741802864

M

311339339459459484484538538538311339339459484484538538

fM

718812858

1054110011711217131713631455

722805866

10771164122513401402

P

250300300350350350350350350350250300300350350350350350

MXV (5)kg (7)

455153626466687072754551546466697274

334380426472518564610656702794338373434495557618679741

DEDN

DN 65-80

185

DK

145 8

DG

118 1965

200 160 8132 1980

EN 1092-2 PN 25 - 40

(6)kg (7)

72,893,3

100,7138140168170192194204

72,893,3

101,7140168171194203

N. Ø

G 1/8(2)

G 3/8(3)

(6) (6)

G 3/8(1)

G 3/8(3)

AD

(4) M

f

P

35

220

260

220

260

14

fM

DN

DKDG

DE

DNDN

h1

a4.93.210/2

220

260

Ø14200

15

43

m4

G 3/8 (3)

G 3/8 (1) (2) (4)

4.93.210/3

MXV 65-3280-48

Dimensions and weights

Vertical Multi-Stage In-Line Pumps

Pump

(1) Filling and air vent(2) Air vent suction side(3) Draining

Motorwithoutmotor

withmotor

Flanges

(4) Standard position of terminal box. (for other positions rotate motor through 90° or 180°) (5) MXV (L) : + 3 kg (6) With standard motor (7) Net weightMXV (H) : + 3 kg

Holes

167

Dimensions and weights

MXV 100-65100-90

MXV 100-6501/AMXV 100-6502-2R/AMXV 100-6502/AMXV 100-6503-2R/AMXV 100-6503/BMXV 100-6504-2R/BMXV 100-6504/AMXV 100-6505-2R/AMXV 100-6505/AMXV 100-6506-2R/AMXV 100-6506/AMXV 100-6507-2R/AMXV 100-6507/AMXV 100-6508-2R/AMXV 100-6508/AMXV 100-9001-1R/AMXV 100-9001/AMXV 100-9002-2R/AMXV 100-9002/AMXV 100-9003-2R/BMXV 100-9003/AMXV 100-9004-2R/AMXV 100-9004/AMXV 100-9005-2R/AMXV 100-9005/AMXV 100-9006-2R/AMXV 100-9006/A

kW f m2m1n2n1 M

mm

fmPN

5,57,51115

18,518,52230303037374545455,57,51115

18,522303037374545

HP

7,510152025253040404050506060607,51015202530404050506060

161616161616161616162525252525161616161616161616162525

M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M180 V1M200 V1M200 V1M200 V1M200 V1M200 V1M225 V1M225 V1M225 V1M132 V1M132 V1M160 V1M160 V1M160 V1M180 V1M200 V1M200 V1M200 V1M200 V1M225 V1M225 V1

190190190190190190190190190190190190190190190199199199199199199199199199199199199

240240240240240240240240240240240240240240240260260260260260260260260260260260260

265265265265265265265265265265265265265265265280280280280280280280280280280280280

316316316316316316316316316316316316316316316341341341341341341341341341341341341

7378298499419411033103311311131122312231315131514071407737737849849941941103810381131113112231223

a

365365365365365365365365365365365365365365365380380380380380380380380380380380380

339339459484538538538636636636636636708708708339339459484538538636636636636708708

107611681308142514791571157117671767185918591951202321152115107610761308133314791479167416741767176719311931

AD

159,5159,5186186206206206315315315315315338338338

159,5159,5186186206206315315315315338338

P

300300350350350350350400400400400400450450450300300350350350350400400400400450450

8185,588,59393

97,598

105,5105,5110110

114,5117,512212282,582,589899393

100100104104

110,5110,5

123,3127,8164,5195215

219,5227

278,5278,5283304

308,5432,5437437

124,8124,8165191215222273273298298

425,5425,5

SizeMXVkg (5)

(4)kg (5)

DN

DK

DE

(4)

230

DEDN

255

180

DK

190

8

8

16

PN

25

19

23

100

100

EN 1092-2

n2

m2

m1

n1

N. 4 x Ø15

DN DN

AD

M

fM

140

a

45

f

P

(1)(1)

(2)

(3)

N. Ø

Pump Motorwithoutmotor

withmotor

(3) Standard position of terminal box. (for other positions rotate motor through 90° or 180°) (4) With standard motor (5) Net weight

Flanges

Holes

Vertical Multi-Stage In-Line Pumps

(1) Filling and air vent(2) Draining

168

MXV EI25-332-540-9

Dimensions and weights

Vertical Multi-Stage In-Line Pumps

ØN.

d

115140

DEDN

150

85100

DK

110

6576

DG

84

141919

444

253240

DNDGDKDE

EN 1092-1 PN 25 - 40

MXV EI 25-304MXV EI 25-305MXV EI 25-306MXV EI 25-307MXV EI 25-308MXV EI 25-310MXV EI 25-312MXV EI 25-314MXV EI 25-316MXV EI 32-504MXV EI 32-505MXV EI 32-506MXV EI 32-507MXV EI 32-508MXV EI 32-510MXV EI 32-512MXV EI 32-514MXV EI 32-516MXV EI 40-904MXV EI 40-905MXV EI 40-906MXV EI 40-907MXV EI 40-908MXV EI 40-910MXV EI 40-911MXV EI 40-913MXV EI 40-915

kW DN

mm

AD m4HP0,750,751,11,11,51,52,22,23

1,11,11,51,52,22,2334

1,52,22,23344

5,55,5

11

1,51,522334

1,51,5223344

5,523344

5,55,57,57,5

M80 V1M80 V1M80 V1M80 V1M90 V1M90 V1M90 V1M90 V1

M100 V1M80 V1M80 V1M90 V1M90 V1M90 V1M90 V1

M100 V1M100 V1M112 V1M90 V1M90 V1M90 V1

M100 V1M100 V1M112 V1M112 V1M132 V1M132 V1

252525252525252525323232323232323232404040404040404040

a

250250250250250250250250250250250250250250250250250250280280280280280280280280280

286286286286286286286286294286286286286286286294294294286286286294294294294321321

AG190190190190190190210210210190190190190210210210210210190210210210210210210210210

AS105105105105105105118118118105105105105118118118118118105118118118118118118118118

M255255255255255255295295311255255255255295295311311311255295295311311311311339339

h1 f

757575757575757575757575757575757575808080808080808080

382,5406,5430,5454,5478,5527

575,5623,5672

382,5406,5430,5454,5478,5527

575,5623,5672

411,5441,5471,5501,5532592622

769,5830

n1205205205205205205205205205205205205205205205205205205250250250250250250250250250

n2180180180180180180180180180180180180180180180180180180215215215215215215215215215

m1165165165165165165165165165165165165165165165165165165190190190190190190190190190

m2100100100100100100100100100100100100100100100100100100130130130130130130130130130

s131313131313131313131313131313131313141414141414141414

g135,535,535,535,535,535,535,535,535,535,535,535,535,535,535,535,535,535,530,530,530,530,530,530,530,530,530,5

fM637,5661,5685,5709,5733,5782

870,5918,5983

637,5661,5685,5709,5773,5822

886,5934,5983

666,5736,5766,5812,5843903933

1108,51169

P200200200200200200200200250200200200200200200250250250200200200250250250250300300

283307331355379

427,5476524

572,5283307331355379

427,5476524

572,5312342372402

432,5492,5522,5583,5644

(5)(6)

-

4.93.210/2

kg

h1

fM

M

DN

DN

ag1

40

m4

200

15

f

n1n2

m1

sm2

170

129Ø15

G 3/8(3)

G 3/8(2)

G 1/4(1)

G 1/4(1)

P

G 3/8(2)

G 3/8(2)

G 3/8(3)

G 1/4(1)

G 1/4(1)

AD

(7)(4)

AS

AG

(4)

Pump

(1) Filling and air vent(2) Air vent suction side(3) Draining(5) MXV EI (H) : + 3 kg

(6) Net weight(7) Pressure transducer

(4) Standard position of I-MAT. (for other positions rotate motor through 90° or 180°)

Motor

Flanges

Holes

169

MXV EI25-332-540-9

Dimensions and weights

Vertical Multi-Stage In-Line Pumps

ØN.1

1 1/4

GDN

1 1/2

2323

w

26

121215

222

253240

PN 16

ØN.DN9595

DE

125

7575

DK

100

M10M10M12

222

253240

PN 16

MXV EI 25-304 OMXV EI 25-305 OMXV EI 25-306 OMXV EI 25-307 OMXV EI 25-308 OMXV EI 25-310 OMXV EI 25-312 OMXV EI 25-314 OMXV EI 32-504 OMXV EI 32-505 OMXV EI 32-506 OMXV EI 32-507 OMXV EI 32-508 OMXV EI 32-510 OMXV EI 32-512 OMXV EI 32-514 OMXV EI 40-904 OMXV EI 40-905 OMXV EI 40-906 OMXV EI 40-907 OMXV EI 40-908 OMXV EI 40-910 OMXV EI 40-911 OMXV EI 40-913 O

kW DN

mm

AD m4HP0,750,751,11,11,51,52,22,21,11,11,51,52,22,233

1,52,22,23344

5,5

11

1,51,52233

1,51,522334423344

5,55,57,5

M80 V1M80 V1M80 V1M80 V1M90 V1M90 V1M90 V1M90 V1M80 V1M80 V1M90 V1M90 V1M90 V1M90 V1

M100 V1M100 V1M90 V1M90 V1M90 V1

M100 V1M100 V1M112 V1M112 V1M132 V1

252525252525252532323232323232324040404040404040

a

160160160160160160160160160160160160160160160160200200200200200200200200

286286286286286286286286286286286286286286294294286286286294294294294321

AG190190190190190190210210190190190190210210210210190210210210210210210210

AS105105105105105105118118105105105105118118118118105118118118118118118118

M255255255255255255295295255255255255295295311311255295295311311311311339

h1 f

505050505050505050505050505050508080808080808080

367391415439463

511,5560608367391415439463

511,5560608

411,5441,5471,5501,5532592622

769,5

n1205205205205205205205205205205205205205205205205250250250250250250250250

n2180180180180180180180180180180180180180180180180215215215215215215215215

m1165165165165165165165165165165165165165165165165190190190190190190190190

m2100100100100100100100100100100100100100100100100130130130130130130130130

s131313131313131313131313131313131414141414141414

g120202020202020202020202020202020

30,530,530,530,530,530,530,530,5

fM622646670694718

766,5855903622646670694758

806,5871919

666,5736,5766,5812,5843903933

1108,5

P200200200200200200200200200200200200200200250250200200200250250250250300

268292316340364

412,5461509

267,5291,5315,5339,5363,5412

460,5508,5312342372402

432,5492,5522,5583,5

(5)(6)

kg

-

4.93.210/2

fM

M

40

m4

15

DK

DE

DN

h1

f

a

DN

DN

g1

200

n1n2

m1

sm2

G 3/8(3)

G 3/8(2)

170

129Ø15

DN G

w

G 3/8(3)

G 3/8(2)

G 1/4(1)

G 1/4(1)

P

G 3/8(2)

G 1/4(1)

G 1/4(1)

AD

(7)(4)

AS

AG

(4)

Pump

(1) Filling and air vent(2) Air vent suction side(3) Draining(5) MXV EI (H) : + 3 kg

(6) Net weight(7) Pressure transducer

(4) Standard position of I-MAT. (for other positions rotate motor through 90° or 180°)

Motor

OvalCounterflanges

Oval Flanges

Holes

Holes

170

MXV EI 50-1550-20

Dimensions and weights

Vertical Multi-Stage In-Line Pumps

MXV EI 50-1502MXV EI 50-1503/AMXV EI 50-1504MXV EI 50-1505MXV EI 50-1506MXV EI 50-1507MXV EI 50-1508/AMXV EI 50-1509MXV EI 50-1510MXV EI 50-1511MXV EI 50-1512MXV EI 50-1513MXV EI 50-1514MXV EI 50-1515MXV EI 50-1516MXV EI 50-1517MXV EI 50-2002MXV EI 50-2003MXV EI 50-2004MXV EI 50-2005MXV EI 50-2006MXV EI 50-2007MXV EI 50-2008MXV EI 50-2009MXV EI 50-2010MXV EI 50-2011MXV EI 50-2012MXV EI 50-2013MXV EI 50-2014MXV EI 50-2015MXV EI 50-2016

kW DN a h1 f

mm

AD m4HP1,52,234

5,55,55,57,57,59,29,211111115152,234

5,57,57,59,29,2111115151515

18,5

234

5,57,57,57,51010

12,512,5151515202034

5,57,51010

12,512,515152020202025

M90 V1M90 V1

M100 V1M112 V1M132 V1M132 V1M132 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M90 V1

M100 V1M112 V1M132 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1

50505050505050505050505050505050505050505050505050505050505050

300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300300

90909090909090909090909090909090909090909090909090909090909090

438486534582693741789837885963

101110591107115512031251438486534645693741819867915963

10111059110711551203

286294294294321321368368368393393393393393471471286294294321368368393393393393471471471471491

M

255311311311339339339339339413413459459459484484295311311339339339413413459459484484484484538

AG

190210210210210210281281281281281281281281350350210210210210281281281281281281350350350350350

AS

105118118118118118153153153153153153153153190190118118118118153153153153153153190190190190190

fM

693797845893

103210801128117612241376142415181566161416871735733797845984

10321080123212801374142214951543159116391741

P

200200250250300300300300300350350350350350350350200250250300300300350350350350350350350350350

313361409457505553601649697745793841889937985

1033313361409457505553601649697745793841889937985

(5)(6)

kg

47,662,564,969,194,696,097,5

111,1112,6145

146,5151,5153,0154,5202,1203,653,063,467,693,1

106,8108,2140,7142,1147,2148,6196,3197,7199,2200,7222,1

165

DEDN

DN 50

125

DK

499

DG

1950

EN 1092-2 PN 25

N. Ø

4.93.210/2

h1

fM

M

DN

DN

a25

250

215

196

13

130 40

m4

200

15

170

129Ø15

P

G 3/8(2)

G 3/8(3)

G 3/8(2)

G 1/4(1)

G 1/4(1)

G 3/8(2)

G 3/8(3)

G 1/4(1)

G 1/4(1)

AD

(7)(4)

AS

AG

(4)

d

DN

DG

DK

DE

(1) Filling and air vent(2) Air vent suction side(3) Draining(5) MXV EI (H) : + 3 kg(6) Net weight(7) Pressure transducer

(4) Standard position of I-MAT. (for other positions rotate motor through 90° or 180°)

Pump Motor

Flanges EN 1092-2 PN 25

Holes

OvalCounterflanges

171

MXV EI 50-1550-20

Dimensions and weights

Vertical Multi-Stage In-Line Pumps

MXV EI 50-1502 OMXV EI 50-1503/A OMXV EI 50-1504 OMXV EI 50-1505 OMXV EI 50-1506 OMXV EI 50-1507 OMXV EI 50-1508/A OMXV EI 50-1509 OMXV EI 50-1510 OMXV EI 50-2002 OMXV EI 50-2003 OMXV EI 50-2004 OMXV EI 50-2005 OMXV EI 50-2006 OMXV EI 50-2007 OMXV EI 50-2008 OMXV EI 50-2009 OMXV EI 50-2010 O

kW DN h1 f

mm

AD m4HP1,52,234

5,55,55,57,57,52,234

5,57,57,59,29,211

234

5,57,57,57,5101034

5,57,51010

12,512,515

M90 V1M90 V1

M100 V1M112 V1M132 V1M132 V1M132 V1M132 V1M132 V1M90 V1

M100 V1M112 V1M132 V1M132 V1M132 V1M160 V1M160 V1M160 V1

505050505050505050505050505050505050

a

200200200200200200200200200200200200200200200200200200

909090909090909090909090909090909090

438486534582693741789837885438486534645693741819867915

286294294294321321368368368286294294321368368393393393

M

255311311311339339339339339295311311339339339413413459

AG

190210210210210210281281281210210210210281281281281281

AS

105118118118118118153153153118118118118153153153153153

fM

6937978458931032108011281176122473379784598410321080123212801374

P

200200250250300300300300300200250250300300300350350350

313361409457505553601649697313361409457505553601649697

(5)(6)

kg

44,859,762,166,391,893,295,2

108,3109,850,260,764,890,3

104,0105,4137,9139,3144,4

4.93.210/2

f

100

130

DN 50

N. 2 M 12

fM

M

250

215

196

13

130 40

m4

200

15

h1

DN

DN

a25

170

129Ø15

G 3/8(3)

G 3/8(2)

G 1/4(1)

G 1/4(1)

P

DN

50

G 2

34

G 3/8(3)

G 1/4(1)

G 1/4(1)

AD

(7)(4)

AS

AG

(4)

(1) Filling and air vent(2) Air vent suction side(3) Draining(5) MXV EI (H) : + 3 kg(6) Net weight(7) Pressure transducer

(4) Standard position of I-MAT. (for other positions rotate motor through 90° or 180°)

Pump Motor

Oval Counterflanges

Oval Flanges

172

MXV EI Vertical Multi-Stage In-Line Pumps

MXV EI

(5)kg (6)

DEDN

DN 65-80

185

DK

145 8

DG

118 1965

200 160 8132 1980

EN 1092-2 PN 25 - 40

N. Ø

MXV EI 65-3202/DMXV EI 65-3203/CMXV EI 65-3204/CMXV EI 65-3205/DMXV EI 65-3206/DMXV EI 65-3207/DMXV EI 65-3208/DMXV EI 65-3209/EMXV EI 65-3210/EMXV EI 65-3212/DMXV EI 80-4802/CMXV EI 80-4803/CMXV EI 80-4804/DMXV EI 80-4805/DMXV EI 80-4806/DMXV EI 80-4807/EMXV EI 80-4808/D

kW DN a h1 f

mm

AD m4HP4

5,57,511111515

18,518,5225,57,5111515

18,522

5,57,510151520202525307,5101520202530

M112 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M160 V1M160 V1M180 V1M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M180 V1

6565656565656565656580808080808080

320320320320320320320320320320320320320320320320320

105105105105105105105105105105105105105105105105105

407473519595641687733779825917466527618680741802864

294321368393393471471491491491321368393471471491491

M

311339339459459484484538538538339339459484484538538

AG

210210281281281350350350350350210281281350350350350

AS

118118153153153190190190190190118153153190190190190

fM

718812858

1054110011711217131713631455805866

10771164122513401402

P

250300300350350350350350350350300300350350350350350

334380426472518564610656702794373434495557618679741

80,8101,3115,5152,8154,8203205227229239

101,3116,5154,8203206229238

DN

DKDG

DE

G 1/8(2)

G 3/8(3)

G 3/8(1)

G 3/8(3)

AD

M

f

P

35

220

260

220

260

14

fM

DNDN

h1

a4.93.210/2

220

260

Ø14200

15

43

m4

G 3/8 (3)

G 3/8 (1) (2)

(4)

(7)(4)

AS

AG

65-3280-48

Dimensions and weights

PumpMotor

Holes

Flanges in accordanceEN 1092-2 PN 25 - 40

(1) Filling and air vent(2) Air vent suction side(3) Draining(4) Standard position of I-MAT

(for other positions rotate motor through 90° or 180°)(5) MXV (L) : + 3 kg, MXV (H) : + 3 kg(6) Net weight (7) Pressure transducer

kW f m2m1n2n1 M

mm

fmPNHP a AD AG ASPSize

MXV EI

kg (4)

DN

DK

DE

AS

AG

230

DEDN

225

180

DK

190

8

8

16

PN

25

19

23

100

100

EN 1092-2

n2

m2

m1

n1

N. 4 x Ø15

DN DN

AD

M

fM

140

a

45

f

P

(5)(1)(1)

(2)

(3)

MXV EI 100-6501/AMXV EI 100-6502-2R/AMXV EI 100-6502/AMXV EI 100-6503-2R/AMXV EI 100-6503/BMXV EI 100-6504-2R/BMXV EI 100-6504/AMXV EI 100-9001/AMXV EI 100-9002-2R/AMXV EI 100-9002/AMXV EI 100-9003-2R/BMXV EI 100-9003/A

7,51015202525301015202530

5,57,51115

18,518,5227,51115

18,522

161616161616161616161616

M132 V1M132 V1M160 V1M160 V1M160 V1M160 V1M180 V1M132 V1M160 V1M160 V1M160 V1M180 V1

190190190190190190190199199199199199

240240240240240240240260260260260260

265265265265265265265280280280280280

316316316316316316316341341341341341

73782984994194110331033737849849941941

365365365365365365365380380380380380

107611681308142514791571157110761308133314791479

339339459484538538538339459484538538

210281281350350350350281281350350350

3213683934714914-1491368393471491491

118153153190190190190153153190190190

300300350350350350350300350350350350

131,3142,6179,3230250

254,5262

139,6179,8226250257

N. Ø

173

Flanges in accordanceEN 1092-2

MXV EI Vertical Multi-Stage In-Line Pumps100-65100-90

Dimensions and weights

Pump Motor

Holes

(1) Filling and air vent(2) Draining(3) Standard position of I-MAT

(for other positions rotate motor through 90° or 180°)(4) Net weight(5) Pressure transducer

174

Features

Vertical Multi-Stage In-Line PumpsMXV

Long Service Life with Standard MotorPump with thrust bearing without additional axial loads on the motor bearings.Any standard motor V1 design (suitable to be lifted in vertical position) can beused, of our choice or of Client’s choice.

Easy Assembly of the MotorWith the single-piece sleeve coupling the pump unit can be supplied fullyassembled also without the motor. This eliminates the risk of damage causedby shifting of the pump shaft during transportation.The motor is simply inserted in the coupling and fastened to the flange with-out the necessity for adapting the axial position of the pump shaft.

Removable mechanical SealEasy removal of the mechanical sealwithout dismantling the motor (for MXV25,32,40,50 and MXV 100 with motorsexceeding 4 KW).

Extra SafetySingle-piece coupling guard to be removed only by means of a tool, positionedaround the lantern bracket, thus avoiding accidental pushing and rubbingagainst the coupling.

Low Cost InstallationVertical construction with reduced pump height for installation in smallspaces. In-line connections to simplify the piping layout with the possibility of insertingthe pump in straight pipe-lines. Disassembly, inspection or cleaning of internal parts without removal of piping.

Robust and ReliableSingle PN 25 construction for all pump sizes.The suction and discharge nozzles arranged in-line absorb the forces of the pip-ing on the pump without the creation of distorting loads causing local friction andearly wears.The lantern brackets compact and robust design maintains a sure alignmentbetween rotating and fixed parts, reducing vibration.The upper cover design prevents entrapment of air around the mechanical seal.

Low-Noise OperationThe water filled shroud around the stages and thick external walls, worktogether for low-noise operation.Low-noise standard motor.

MXV 25,32,40,50

3.93.112

MXV 25, 32, 40, 50

MXV 65, 80

175

Vertical Multi-Stage In-Line Pumps

ConstructionVertical multi-stage pumps with suction and delivery connections ofthe same diameter and arranged along the same axis (in-line).Corrosion-resistant bearing sleeves lubricated by the pumped liquid.Removal of the mechanical seal without dismantling the motor(for MXVL 25, 32, 40, 50, 100 with motors exceeding 4 KW).A pump with thrust bearing and sleeve coupling for use of anystandard motor with IM V1 construction.

Version with frequency converter (on request)

ApplicationsFor water supply systems.For clean non-explosive liquids, without solid, filamentary orabrasive matter (with adaptation of sealing materials on request).A universal pump for civil and industrial use, for pressure-boostingsystems, fire-extinguishing systems, high-pressure washingplants, irrigation, agricultural uses and sport installations.

Operating conditionsTemperature of liquid: from -15 °C to +110 °C.Operating environment temperature: up to 40 °C.Maximum permissible pressure in pump casing: 25 bar. (16 bar for pumps with oval flanges).

MotorStandard-type: 2-pole induction motor, 50 Hz (n ≈ 2900 rpm).Construction IM V1 (EN 60034-7).Motor suitable for operation with frequency converter.Classification scheme IE3 for three-phase motors.Insulation class F.Protection IP 55.three-phase with rated voltage: up to 3 kW 230/400 V;

from 4 kW 400/690 V.

MXVL 25, 32, 40, 50 MXVL 65, 80, 100

Pump with flanged ports (F).Pump with oval flange ports (O) (for MXVL 25, 32, 40, 50).Pump without motor.Pump with standard motor.

Variants (to be specified when ordering)

With counter-flanges in chrome-nickel steel.O-rings FPM. Other mechanical seal.Pump with motor of Client's choice (if available).Single-phase motor 230 V, up to 2.2 kW.Pump with support feet for horizontal installation (H1 or H2).Other voltage ratings. Frequency 60 Hz.

Other variants (on request)

Direction of rotation: clockwise as seen from the motor.Direction of rotation: anticlockwise as seen from the motor.(clockwise as seen from the motor for MXVL 100)

Pump without motor.Pump with standard motor.

Variants (to be specified when ordering)

O-rings FPM. Other mechanical seal.Pump with motor of Client's choice (if available).Other voltage ratings. Frequency 60 Hz. Pump with support feet for horizontal installation (H1 or H2) MXV 100series excluded.

Other variants (on request)

Component Material

FlangeExternal jacketSuction casingDelivery casing Stainless SteelStage casing 1.4404 EN 10088 (AISI 316L)ImpellerLower coverUpper coverSpacer sleevePump shaft Stainless SteelPlug 1.4404 EN 10088 (AISI 316L)Bearing sleeve Corrosion-resistant, cemented carbideBearing in stage casing Ceramic aluminaMechanical seal ISO 3069 - KU Hard metal/Carbon/EPDM.

Wear ring PPS (PTFE for MXV 40)O-rings NBR (EPDM for MXV 50)Oval Counterflanges Stainless Steel (AISI 316)Counterflanges (on request) Stainless Steel (AISI 316)

Materials (wetted parts)

All parts that come into contact with the liquid, including wet-endcovers, are in chrome-nickel-molybdenum stainless steel AISI 316L.

Internal parts in contact with the liquid with pump casing and uppercover in chrome-nickel-molybdenum stainless steel AISI 316L.

Component Material

Pump casing Stainless SteelUpper cover 1.4404 EN 10088 (AISI 316L)

External jacketStage casing Stainless SteelImpeller 1.4404 EN 10088 (AISI 316L)Spacer sleevePump shaft Stainless Steel (AISI 316L)(AISI 329 for MXVL 100)Plug Stainless Steel 1.4404 EN 10088 (AISI 316L)Bearing sleeve Corrosion-resistant, cemented carbideBearing in stage casing Ceramic alumina

(Corrosion-resistant, cemented carbide for MXVL 100)Mechanical sealISO 3069 - KU

Hard metal/Carbon/EPDM

Wear ring PTFEO-rings NBR (EPDM for MXV 100)Counterflanges Stainless Steel (AISI 316)(on request)

Materials (wetted parts)

The electropumps MXVL series comply with the European Regulation no. 547/2012.

MXVL AISI 316L

2 4 8 3216 481 3 5 6 7 9 10 20 40 70600

50

100

150

200

250

0m /h

l/min 30 40 50 100 1000150 200

80 90100 150

1500 2000300 400 500

3

72.936/1

5 10 20 304

m

50 10040 200 300 500400Imp. g.p.m.

ft

Q

H

25-3 32-5 40-9

50-15

65-32

80-48

100-65

100-90

H

100

200

300

400

500

700

800MXVn≈ 2900 1/min

50-20

176

Coverage chart

For characteristic curves, dimensions and weights see MXV

Vertical Multi-Stage In-Line PumpsMXVL AISI 316L

MXVL