MYK Aquafin 2CTwo Component Flexible Crack Bridging Waterproof Coating
Description: Two component polymer modified seamlessand jointness flexible crack bridging
waterproofing. Suitable for all Waterproofing
applications and similar surfaces
Hydraulic settingRapid rain proof in 3 - 5 Hrs @ 30Resistance to water pressure up to 7 bars (+ve side) Environment friendly Bonds on wet surface without priming Resistant to carbonation Easy and economical application simpleapplication by spray, roller, trowel or
UV resistance Resistant to aggressive water soil acids etcFor fixing tiles in water retaining structures
Fields of application:
Exterior waterproofing of old and newbuildings against ground moisture, humidity,
pressure water Waterproofing of water tanks Waterproofing systems for high water heads Horizontal waterproofing below masonry Interior waterproofing against humidity from
outside
Waterproofing of underground basements,precast garages, ducts, areas of high humidity,
terraces, balconies and swimming pools
For fixing of MYK Aso-joint tape 2000, Aso-Joint tape 2000S, and MYK -Joint sleeves
economic tiling in wet rooms when used as an
underlay
MYK Aquafin 2C is an economicwaterproofing underneath tiles in wet rooms.
Technical Data:Powder Component :Sand/cement
Liquid Component :Polymer dispersion
Mixing ratio : 24:11(Powder: Liquid)
Pot Life @ 27 oC & 60 % RH 30 minutes
@ 20 oC & 60 % RH 60 minutes
Time between recoat :4 hrs @ 30oC
Mixing time :2 to 3 minute with
mechanical Mixer
Processing time :60 Min @20 oC
Processing temperature :+5 to +30
Tensile Elongation :157% at 30oC
Vapor Diffusion Resistance :Approx 1000
Consumption:Type of
application
Water head Total
Recommended
consumption(Kg
/Sq mtr)
Min Dft
(mm)**
Roofs composite
waterproofing
Below 1 Mtr
Traffic
2.5-3.0
3.0-4.0*
1.3
1.5
Balconies/terrace non Tiled
Tiled
3.0-4.0
4.0
1.5
2.0
Swimming Pools Small-
Medium
3.0 1.5
Fountains upto 1Mtr
upto 1.5Mtr
2.0-2.5
3.0-3.5
1.0
1.5
Water tanks NormalPotable
3.0-4.54.0-4.5
1.52.0
Below Grade Below 2MtrBelow 2-4Mtr
Below 4-7Mtr
Below 7-10MtrAbove 10Mtr
2.0-2.53.0
3.5
4.04.5
1.01.5
1.8
2.02.3
* depends on the amount of traffic.
** Minimum thickness of the cured film at any point
of the coating. This are technical limits of the
products and do not reflect legal requirements for
your application. Please review local building codes
for the confirming minimum film thickness. These
may be higher then the technical possible minimum
value stated.
Uneven surfaces may demand more material to reach
the specific thickness.
Surface Preparation:The surface to be coated must comply with the
principles of building construction and should full fill
the structural requirements including properly
designed sloped to avoid stagnation of water in case
of roofs. Any cracks pot holes expansion joints etc
should be firm, clean, free from fats, oil grease, dust
or any other contaminations MYK Aquafin 2C is
suitable for smooth concrete, screed, mastic asphalt,
plasters gypsum boards and masonry. Coarsely pored
surfaces like gutter blocks or Precast concrete blocks
oC
Properties:
stiff brush
have to be grouted with cement mortar or
oC
Rev
(1):
15.0
6.09
Plant Root resistance
Hardness Shore A Scale : 9 0
8/4/2019 MYK Aquafin 2C
2/2
MYK Crete RN. Highly absorbent surfaces like
light weight concrete or gypsum boards may beprimed with MYK ASO-Unigrund GE (Acrylic
primer) to reach an improved adhesion
Mixing Instructions and Application:
MYK Aquafin 2C consists of a powder and liquid
component. The liquid component of approx 2/3
should be emptied into a clean mixing vessel,
add slowly the powder to it. While mixing with a
slow speed mixing paddle (approx 300 rpm) until a
consistent, homogeneous, lump free mass is
Existing cracks can be treated with MYK Aquafin
2C by embedding the MYK Aso joint tape into the
first layer
For moving cracks and construction joints use
MYK ASO joint tape 2000S
Annotation:
When the coating is hardening, it must not beinfluenced by water, negative water can lead to
ruptures under frost condition
In areas of high humidity, extended curing timehas to be taken into account
Avoid direct sunlight Low chromate level
Cleaning of equipments: - In wet state with water.
Packaging : Available in 35 kg Composite Pack
24Kgs- Powder Component
11 Kgs-Polymer Liquid Component
Storage & Shelf life
Store in dry & cool place in shaded area & kept away
from freezing. Shelf life is 6 months from the date of
manufacturing in original un opened packaging.
Consume open packs immediately.
Quality PolicyThe information given in the date sheet is based on
the years of experience, and found correct to the best
of our knowledge. However the success of the product
& its application is dependent on many external
factors. We are fully assured of our products quality at
the time of dispatch. As we are constantly
endeavoring to enhance the qualities of our products
which may reflect changes it the data sheets. Hence in
the event of any doubt on critical parameters it is
advisable to consult our technical department
Technical Support:
Technical information regarding Schomburg range of
products can be obtained from the technical cell ofMYK Schomburg
Note:
Information in this technical data sheet is to the best
of our knowledge true and accurate. However, such
conditions under which our products may be used are
beyond our control, recommendations
MYK Aquafin 2CTw o Component Flexible Cracks B ridging W aterproof Coating
MYK SCHOMBURG INDIA PVT LTD (An Indo-German JV) 6-3-569/2, First Floor, Kamadhenu Complex, Rockdale Compound, Somajiguda, Hyderabad - 500 082Tel: +91 40 3060 3060/1/2/3 Fax: +91 40 3060 3067 email: [email protected] www.mykschomburg.com
produced. After that, add the remaining liquid
component, and stir until the uniform consistency
is achieved. The surface has to be pre-wetted withwater (SSD condition) at the moment of
application of the product. MYK Aquafin 2C can
be applied by brush, trowel or appropriate spray
equipment. At least two layers of MYK Aquafin
2C are necessary. Every part of the waterproofing
must have the minimum layer for the expected
moisture quantity. The application of the second
layer is done when the first layer cannot be
damaged by the further application (at +30oC 4 hrs
at the earliest). Due to possibility of the crack
formations avoid applied thickness grater then 2
kg/m2 = (1 mm dry film thickness) in one
application to prevent the formation of the crack.