NA62 DCS CAN bus lines. Short reminder. General properties of CAN bus Up to 64 nodes on one bus Different devices need different buses (WIENER, ISEG, ELMB,?) Transition rate depends on the length of cable (from 1 Mbit /s for 25m to 10 kbit /s for 5000m) - PowerPoint PPT Presentation
Citation preview
122/03/11 FV
NA62 DCS CAN bus lines
VF 2
Short reminder
• General properties of CAN buso Up to 64 nodes on one buso Different devices need different buses (WIENER, ISEG, ELMB,?)o Transition rate depends on the length of cable (from 1 Mbit/s for
25m to 10 kbit/s for 5000m)o Characteristic impedance 120 Ohm, termination on both endso The starting point of the CANbus cables is DCS rack(s) in the PC
farm area (b.918)
• ISEG CAN buso One module has two CAN-nodes, crate is one node. So one fully
populated crate with 8 Modules EDS 20 130n_504 equals 17 CAN-nodes
o Not more than 3 crates per cableo Peak PCAN-PCI two channel cards
22/03/11
VF 3
Short reminder -2
• ELMB CAN buso In addition to the CAN bus signals the cable also provide the
power for the ELMBs (12V) o Thick cable (SCEM code 04.21.60.491.2) will be used for long
distance to minimize the voltage drop, thin cable (SCEM code 04.21.60.430.5) for local distribution + junction box “a la ATLAS” (has to be investigated)
o Fixed double cable “PHOENIX CONTACT” connectorso Kvaser PCIcanx 4xHS cards
• WIENER CAN buso Kvaser PCIcanx 4xHS cardso TCP/IP option for the WIENER equipment control is under
consideration. Price for one fan-tray unit• CAN bus: 627 EURO• TCP/IP: 755 or 991 EURO• In total we will have about 60 crates
22/03/11
VF 4
Experimental Area
22/03/11
PC farm area
VF 5
ISEG CAN bus lines
22/03/11
GT 854 (to PC farm)GT 853 (to NA48 CR)
• MUV, SAV• LAV 12, 11, 10• LAV 9, 8, 7• LAV 6, 5, 4• LAV 3, 2, 1• CEDAR (?)
VF 6
ISEG CAN bus lines
22/03/11
• LAV 3, 2, 1
• CEDAR (?)
VF 7
WIENER crate control CAN bus lines
22/03/11
GT 854 (to PC farm)GT 853 (to NA48 CR)
• LKr• All other crates in EB, LAV12, LAV11, LAV10• Straw tracker• LAV 9, 8, 7, 6, 5, 4, 3, 2, 1, CHANTI, GTK (?),
CEDAR
VF 8
WIENER crate control CAN bus lines
8/02/11
• LAV 5, 4, 3, 2, 1, GTK (?), CHANTI, CEDAR
VF 9
ELMB CAN bus lines
8/02/11
• LKr• RICH, MUV, SAV• STRAW 1• STRAW 2• STRAW 3• STRAW 4• CHANTI, GTK3, GTK2, GTK1, CEDAR
VF 10
• Other CAN bus lineso CAN bus cables for LAV thresholds (one cable per
station) o Gas systems (one cable per system ?)o CEDAR NINO front-end cards control (one cable)?o RICH NINO front-end card control ?
22/03/10