* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments. For more details see www.nathers.gov.au Nationwide House Energy Rating Scheme* Certificate Certificate number: Certificate Date: ê Star rating: MJ/m 2 Assessor details Accreditation number: Name: Organisation: Email: Phone: Declaration of interest: Key construction and insulation materials (see following pages for details) Construction: Insulation: Glazing: Plan documents Plan ref/date: Prepared by: Net floor area (m 2 ) Conditioned: Unconditioned: Garage: TOTAL: Annual thermal performance loads (MJ/m 2 ) Heating: Cooling: TOTAL: Dwelling details Street: Suburb: State: Type: Lot/DP number: Postcode: NCC Class: NatHERS climate zone: Ceiling penetrations (see following pages for details) Sealed: Unsealed: TOTAL:** **NOTE: This total is the maximum number of ceiling penetrations allowed to a ceiling (under a roof) for this certificate. If this number is exceded in construction then this certificate IS NOT VALID and a new certificate is required. Loss of ceiling insulation for the penetrations listed has been taken into account with the rating. Principle downlight type: Window selection - default windows only Note on allowable window values: Only a 5% tolerance to the nominated SHGC window values shown on page 2 can be used with this rating. Note: Only a +/- 5% SHGC tolerance is allowed with this rating. NB: This tolerance ONLY applies to SHGC, the U-value can always be lower but not higher than the values stated on page 2. If any of windows selected are outside the 5% tolerance then this certificate is no longer valid and the dwelling will need to be rerated to confirm compliance. Overview Scan to access this certificate online and confirm this is valid. Software: AAO: Exposure: 13 Oct 2017 0001827237-01 5.4 BERS Pro v4.3.0.0 (3.13) cannot be used to model 'roof windows'. Roof windows are 'openable or fixed windows in a roof' and do not have a shaft, as distinct from skylights which incorporate a built-in shaft and are not ventilated. BERS Pro v4.3 can only model skylights. If a roof window is present on the floor plan then this certificate is not valid. 5.4 20733 Paula Zaia Aspect Z [email protected] 02 43210970 The Assessor has been engaged in the project design or development BERS Pro v4.3.0.2a (3.13) ABSA 79.0 107 Alan Street Niagara Park NSW 2250 New Dwelling 1A 15 16/2480 Suburban 21 9 30 Fibro Cavity Panel Direct Fix Corrugated Iron Waffle pod slab 225 mm R2.0 wall insulation R4.0 ceiling insulation No floor insulation LED ALM-002-03 A Aluminium B SG High Solar Gain Low-E 169.0 9.0 0.0 178.0 49.0 29.0 79.0 NES-02-07 Aspect Z Page 1 of 6

Nationwide House Energy Rating Scheme* Certificate · and a new certificate is required **NOTE: This total is the maximum number of ceiling penetrations allowed to a ceiling (under

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Nationwide House Energy Rating Scheme* Certificate · and a new certificate is required **NOTE: This total is the maximum number of ceiling penetrations allowed to a ceiling (under

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments.For more details see www.nathers.gov.au

Nationwide House Energy Rating Scheme* Certificate Certificate number: Certificate Date: êStar rating:

MJ/m2

Assessor details

Accreditation number: Name: Organisation:Email: Phone: Declaration of interest:

Key construction and insulation materials (see following pages for details)

Construction:

Insulation:

Glazing:

Plan documents

Plan ref/date: Prepared by:

Net floor area (m2)

Conditioned: Unconditioned: Garage: TOTAL:

Annual thermal performance loads (MJ/m2)

Heating: Cooling: TOTAL:

Dwelling details

Street: Suburb: State:

Type:

Lot/DP number:

Postcode:NCC Class:NatHERSclimate zone:

Ceiling penetrations (see following pages for details)

Sealed: Unsealed: TOTAL:**

**NOTE: This total is themaximum number of ceilingpenetrations allowed to aceiling (under a roof) for thiscertificate. If this number isexceded in construction thenthis certificate IS NOT VALIDand a new certificate is required.Loss of ceiling insulation for thepenetrations listed has beentaken into account with the rating.

Principle downlight type:

Window selection - default windows only

Note on allowable window values:Only a 5% tolerance to the nominatedSHGC window values shown on page 2can be used with this rating.

Note: Only a +/- 5% SHGC tolerance is allowed with this rating.

NB: This tolerance ONLY applies to SHGC, the U-value can always be lower but not higher than the values stated on page 2.

If any of windows selected are outside the 5% tolerance then this certificate is no longer valid and the dwelling will need to be rerated to confirm compliance.

Overview

Scan to access this certificate online and confirm this is valid.

Software:

AAO:

Exposure:

13 Oct 20170001827237-01 5.4BERS Pro v4.3.0.0 (3.13) cannot be used to model 'roof windows'. Roof windows are 'openable or fixed windows in a roof' and do not have a shaft, as distinctfrom skylights which incorporate a built-in shaft and are not ventilated. BERS Pro v4.3 can only model skylights. If a roof window is present on the floor planthen this certificate is not valid.

5.420733Paula ZaiaAspect [email protected] 43210970The Assessor has been engaged in theproject design or developmentBERS Pro v4.3.0.2a (3.13)

ABSA

79.0107 Alan StreetNiagara ParkNSW 2250New Dwelling 1A

1516/2480 Suburban

219

30Fibro Cavity Panel Direct FixCorrugated IronWaffle pod slab 225 mmR2.0 wall insulationR4.0 ceiling insulationNo floor insulation

LED

ALM-002-03 A Aluminium B SG HighSolar Gain Low-E

169.09.00.0

178.049.029.079.0

NES-02-07Aspect Z

Page 1 of 6

Page 2: Nationwide House Energy Rating Scheme* Certificate · and a new certificate is required **NOTE: This total is the maximum number of ceiling penetrations allowed to a ceiling (under

Window type and performance valueWindow ID Window type U-value SHGCALM-002-03 A ALM-002-03 A Aluminium B SG High Solar Gain Low-E 5.4 0.58ALM-001-03 A ALM-001-03 A Aluminium A SG High Solar Gain Low-E 5.4 0.49TIM-001-01 W TIM-001-01 W Timber A SG Clear 5.4 0.56ALM-002-01 A ALM-002-01 A Aluminium B SG Clear 6.7 0.70ALM-001-01 A ALM-001-01 A Aluminium A SG Clear 6.7 0.57

Window scheduleLocation Window ID Window no. Height (mm) Width (mm) Orientation Outdoor shadeLiving/Dining ALM-002-03 A n/a 1800 900 SW No ShadingLiving/Dining ALM-002-03 A n/a 1500 730 NW No ShadingLiving/Dining ALM-001-03 A n/a 1500 1600 NE No ShadingLiving/Dining ALM-001-03 A n/a 1500 1600 NE No ShadingLiving/Dining ALM-001-03 A n/a 2100 3890 NE Horizontal

Louvres,Horizontal Blades

Living/Dining ALM-002-03 A n/a 1500 730 SE No ShadingLiving/Dining TIM-001-01 W n/a 1600 900 NE No ShadingLiving/Dining ALM-002-03 A n/a 1000 6900 NE No ShadingPowder ALM-002-01 A n/a 900 600 NE No ShadingPowder TIM-001-01 W n/a 1600 900 NE No ShadingBath ALM-001-01 A n/a 900 1400 SW No ShadingEnsuite ALM-001-01 A n/a 900 1200 SE No ShadingMaster ALM-002-03 A n/a 2400 500 SE No ShadingMaster ALM-002-03 A n/a 2400 500 SE No ShadingMaster ALM-001-03 A n/a 2400 1600 SE No ShadingMaster ALM-002-03 A n/a 1900 720 SW No ShadingMaster ALM-002-03 A n/a 1900 720 SW No ShadingMaster ALM-002-03 A n/a 1900 720 SW No ShadingGuest ALM-002-03 A n/a 300 2700 NE No ShadingGuest ALM-002-03 A n/a 1600 350 NE No ShadingGuest ALM-002-03 A n/a 1600 1500 SE No ShadingGuest ALM-002-03 A n/a 1600 350 SW No ShadingBedroom 3 ALM-002-03 A n/a 1900 700 SW No ShadingBedroom 3 ALM-002-03 A n/a 1900 700 SW No ShadingBedroom 4 ALM-002-03 A n/a 1900 700 NE No ShadingBedroom 4 ALM-002-03 A n/a 1900 700 NE No ShadingKitchen/Laundry ALM-002-03 A n/a 1800 900 SW No ShadingKitchen/Laundry ALM-001-03 A n/a 1510 4710 SW No Shading

Roof window and skylight type and performance valueID Window type U-value SHGCGEN-04-008a Double-glazed clear, Timber and Aluminium Frame 0.0 0.00

Roof window and skylight scheduleLocation ID Roof

window/skylightArea (m²) Orientation Outdoor shade Indoor

shade/diffuser

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments. For more details see www.nathers.gov.au Page 2 of 6

Nationwide House Energy Rating Scheme* CertificateCertificate number: 0001827237-01 Certificate Date: 13 Oct 2017 ★ Star rating: 5.4

Building features

Page 3: Nationwide House Energy Rating Scheme* Certificate · and a new certificate is required **NOTE: This total is the maximum number of ceiling penetrations allowed to a ceiling (under

no.Bedroom 3 GEN-04-008a 1 0.5 NW None NoBedroom 4 GEN-04-008a 1 0.5 NW None No

External wall typeID Wall type Insulation Wall wrap or foilEW-1 Fibro Cavity Panel Direct Fix Foil, Anti-glare one side + Bulk Insulation R2 Yes

External wall scheduleLocation ID Width (mm) Height (mm) Orientation Fixed Shade Eaves

(mm)Living/Dining EW-1 2690 2700 SW No 500Living/Dining EW-1 1100 2700 NW No 600Living/Dining EW-1 10300 2700 NE No 1400Living/Dining EW-1 1100 2700 SE No 6100Living/Dining EW-1 1295 2700 NE No 2500Powder EW-1 1690 2700 NE No 500Bath EW-1 1590 2700 SW No 500Ensuite EW-1 1495 2700 SE No 500Ensuite EW-1 1000 2700 SW No 3600Master EW-1 3095 2700 SE No 1500Master EW-1 5095 2700 SW No 500Guest EW-1 4795 2700 NE No 2500Guest EW-1 900 2700 SE No 500Guest EW-1 400 2700 NE No 1400Guest EW-1 1500 2700 SE No 100Guest EW-1 400 2700 SW No 6100Guest EW-1 995 2700 SE No 500Bedroom 3 EW-1 3600 2700 SW No 500Bedroom 3 EW-1 3995 2700 NW No 525Bedroom 4 EW-1 3995 2700 NW No 575Bedroom 4 EW-1 3595 2700 NE No 500Kitchen/Laundry EW-1 7690 2700 SW No 500

Internal wall typeWall type Area (m²) Insulation Wall wrap or foilIW-1 - Cavity wall, direct fixplasterboard, single gap

132.0 No insulation No

FloorsLocation Construction Area (m²) Sub floor

ventilationAddedinsulation

Covering

Living/Dining Waffle pod slab 225 mm 100mm 85.1 None Waffle Pod225mm

Ceramic Tiles8mm

Powder Waffle pod slab 225 mm 100mm 4.8 None Waffle Pod Ceramic Tiles

Nationwide House Energy Rating Scheme* CertificateCertificate number: 0001827237-01 Certificate Date: 13 Oct 2017 ★ Star rating: 5.4

Building features continued

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments. For more details see www.nathers.gov.au Page 3 of 6

Page 4: Nationwide House Energy Rating Scheme* Certificate · and a new certificate is required **NOTE: This total is the maximum number of ceiling penetrations allowed to a ceiling (under

225mm 8mmBath Waffle pod slab 225 mm 100mm 4.3 None Waffle Pod

225mmCeramic Tiles8mm

Ensuite Waffle pod slab 225 mm 100mm 5.1 None Waffle Pod225mm

Ceramic Tiles8mm

Master Waffle pod slab 225 mm 100mm 15.4 None Waffle Pod225mm

Cork Tiles orParquetry 8mm

Guest Waffle pod slab 225 mm 100mm 16.6 None Waffle Pod225mm

Cork Tiles orParquetry 8mm

Bedroom 3 Waffle pod slab 225 mm 100mm 14.1 None Waffle Pod225mm

Cork Tiles orParquetry 8mm

Bedroom 4 Waffle pod slab 225 mm 100mm 14.1 None Waffle Pod225mm

Cork Tiles orParquetry 8mm

Kitchen/Laundry Waffle pod slab 225 mm 100mm 18.7 None Waffle Pod225mm

Ceramic Tiles8mm

Ceiling typeLocation Construction Added

insulationRoof spaceabove

Living/Dining Plasterboard Bulk InsulationR4

Yes

Powder Plasterboard Bulk InsulationR4

Yes

Bath Plasterboard Bulk InsulationR4

Yes

Ensuite Plasterboard Bulk InsulationR4

Yes

Master Plasterboard Bulk InsulationR4

Yes

Guest Plasterboard Bulk InsulationR4

Yes

Bedroom 3 Plasterboard Bulk InsulationR4

Yes

Bedroom 4 Plasterboard Bulk InsulationR4

Yes

Kitchen/Laundry Plasterboard Bulk InsulationR4

Yes

Ceiling penetrationsLocation Number Type Diameter (mm) Sealed/unsealedLiving/Dining 12 Downlights - LED 150 SealedLiving/Dining 1 Exhaust Fans 300 SealedPowder 1 Downlights - LED 150 UnsealedPowder 1 Exhaust Fans 300 SealedBath 1 Downlights - LED 150 UnsealedBath 1 Exhaust Fans 300 SealedEnsuite 1 Downlights - LED 150 UnsealedEnsuite 1 Exhaust Fans 300 SealedMaster 2 Downlights - LED 150 SealedGuest 2 Downlights - LED 150 Unsealed

Nationwide House Energy Rating Scheme* CertificateCertificate number: 0001827237-01 Certificate Date: 13 Oct 2017 ★ Star rating: 5.4

Building features continued

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments. For more details see www.nathers.gov.au Page 4 of 6

Page 5: Nationwide House Energy Rating Scheme* Certificate · and a new certificate is required **NOTE: This total is the maximum number of ceiling penetrations allowed to a ceiling (under

Bedroom 3 2 Downlights - LED 150 UnsealedBedroom 4 2 Downlights - LED 150 UnsealedKitchen/Laundry 3 Downlights - LED 150 Sealed

Ceiling fansLocation Number Diameter (mm)None Present

Roof typeConstruction Added

insulationRoof colour

Corrugated Iron Bulk, ReflectiveSide Down, Anti-glare Up R1.3

Medium

Nationwide House Energy Rating Scheme* CertificateCertificate number: 0001827237-01 Certificate Date: 13 Oct 2017 ★ Star rating: 5.4

Building features continued

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments. For more details see www.nathers.gov.au Page 5 of 6

Page 6: Nationwide House Energy Rating Scheme* Certificate · and a new certificate is required **NOTE: This total is the maximum number of ceiling penetrations allowed to a ceiling (under

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territory governments.

For more details see www.nathers.gov.au

Certificate Date:

Explanatory notes

Accredited Assessors

To ensure you get a high-quality, professional NatHERS House Energy Rating report, you should always use an

Organisation (AAO).

and continuing professional development requirements to maintain a high and consistent standard of assessments across the country. Non-accredited assessors do not have this level of quality assurance or any on-going training requirements.

concerns, please contact their AAO listed under ‘assessor

Disclaimer

The energy values quoted are for comparison purposes only; they are not a prediction of actual energy use. This rating

the rating.

Contact

For more information on the Nationwide House Energy Rating Scheme (NatHERS), visit www.nathers.gov.au

insulation visit www.yourhome.gov.au

About this report

including heating and cooling, hot water, dishwashers, ovens,

General Information

A NatHERS House Energy Rating is a comprehensive, dynamic computer modelling evaluation of the floorplans, elevations and specifications to predict an energy load of a home. Not all of us use our homes in the same way, so ratings are generated using standard assumptions. This means homes can be compared across the country.

The actual energy consumption of your home may vary significantly from the predicted energy load figures in the report depending on issues such as the size of your household and your personal preferences, e.g. in terms of heating or cooling.

While the figures are an indicative guide to energy use, they can be used as a reliable guide for comparative purposes between different house designs and for demonstrating that the design meets the required regulatory compliance.

Homes that are energy efficient use less energy, are warmer in winter, cooler in summer and cost less to run. The higher the star rating the more energy efficient.

This NatHERS House Energy Rating report was carefully prepared by your assessor on the basis of comprehensive modelling using standard procedures to rate your home using the underlying engine developed by the Australian Commonwealth Scientific and Industrial Research Organisation (CSIRO).

All information relating to energy loads presented in this report is based on a range of standard assumptions in order to allow for comparisons with reports prepared for other homes and to demonstrate minimum regulatory compliance.

The standard assumptions include figures for occupancy, indoor air temperature and are based on a unique climate file for your region.

Additional information

0001827237-01 13 Oct 2017 5.4