Nemo BTS Fileformat 1.15

  • Upload
    krsac

  • View
    278

  • Download
    5

Embed Size (px)

Citation preview

  • 8/16/2019 Nemo BTS Fileformat 1.15

    1/28

    WWW.ANITE.COM/NEMO

    © Anite 2014

    BTS FILE FORMATVERSION 1.15

    DOCUMENT NUMBERNNNNNNNNN ISSUE N

  • 8/16/2019 Nemo BTS Fileformat 1.15

    2/28

    BTS FILE FORMAT

    Page 2

    Copyright

    The information contained in this document is confidential and no part of it may be copied or

    reproduced in any form without the written consent of Anite Network Testing. Additionally, this

    document is not to be passed to or discussed with third parties without the prior written permission

    of Anite Network Testing.

    Anite’s products are subject to continual development and specifications may change. Users of

    Anite’s products and documentation should exercise their own independent judgement to evaluate

    the suitability of Anite’s products and documentation for their particular use. Anite does not accept

    any liability arising from the application or use of the product or this documentation.

    All reasonable care has been made to ensure that this document is accurate. If you have any

    comments on this document, or would like details of any Anite products, services or equipment,

    please contact us through the Anite website.

  • 8/16/2019 Nemo BTS Fileformat 1.15

    3/28

    BTS FILE FORMAT

    Page 3

    CONTENTS

    GENERAL STRUCTURE ...................................................................................... 5 

    CREATING BTS FILES ....................................................................................... 6 

    PARAMETERS .................................................................................................. 7 

    3.1 

    Mandatory cell parameters ........................................................................ 7 

    3.2 

    Optional cell parameters ........................................................................... 7 

    3.3  AMPS cell parameters ............................................................................... 9 

    3.3.1  Mandatory parameters ...................................................................... 9 

    3.3.2 

    Optional parameters ......................................................................... 9 

    3.3.3 

    Cell search method .......................................................................... 10 

    3.4 

    GSM cell parameters ................................................................................ 11 

    3.4.1 

    Mandatory parameters ..................................................................... 11 

    3.4.2 

    Optional parameters ........................................................................ 11 

    3.4.3 

    Cell search method .......................................................................... 12 

    3.5 

    CDMA cell parameters .............................................................................. 13 

    3.5.1 

    Mandatory parameters ..................................................................... 13 

    3.5.2 

    Optional parameters ........................................................................ 13 

    3.5.3 

    Cell search method .......................................................................... 14 3.6

     

    UMTS cell parameters .............................................................................. 15 

    3.6.1 

    Mandatory parameters with 28-bit cell ID ........................................... 15 

    3.6.2 

    Mandatory parameters with 16-bit cell ID and RNC ID .......................... 15 

    3.6.3 

    Optional parameters ........................................................................ 16 

    3.6.4 

    Cell search method .......................................................................... 17 

    3.7 

    TETRA cell parameters ............................................................................. 17 

    3.7.1 

    Mandatory parameters ..................................................................... 17 

    3.7.2 

    Optional parameters ........................................................................ 17 

    3.7.3 

    Cell search method .......................................................................... 18 

    3.8 

    TD-SCDMA cell parameters ....................................................................... 18 

    3.8.1 

    Mandatory parameters ..................................................................... 18 

    3.8.2 

    Optional parameters ........................................................................ 19 

    3.8.3 

    Cell search method .......................................................................... 19 

    3.9 

    WIMAX cell parameters ............................................................................ 20 

    3.9.1 

    Mandatory parameters ..................................................................... 20 

    3.9.2 

    Optional parameters ........................................................................ 20 

    3.9.3 

    Cell search method .......................................................................... 21 

    3.10 

    EVDO cell parameters .............................................................................. 22 

    3.10.1 

    Mandatory parameters ..................................................................... 22 

    3.10.2 

    Optional parameters ........................................................................ 22 

    3.10.3 

    Cell search method .......................................................................... 23 

  • 8/16/2019 Nemo BTS Fileformat 1.15

    4/28

    BTS FILE FORMAT

    Page 4

    3.11 

    LTE cell parameters ................................................................................. 24 

    3.11.1 

    Mandatory parameters ..................................................................... 24 

    3.11.2 

    Optional parameters ........................................................................ 24 

    3.11.3 

    Cell search method .......................................................................... 25 

    3.12 

    IDEN cell parameters ............................................................................... 26 

    3.12.1 

    Mandatory parameters ..................................................................... 26 

    3.12.2 

    Optional parameters ........................................................................ 26 

    3.12.3 

    Cell search method .......................................................................... 26 

    TECHNICAL SUPPORT ...................................................................................... 27 

    4.1 

    User Club ............................................................................................... 27 

    4.2 

    Nemo Support Portal ............................................................................... 27 

    4.3  Phone and Email Support ......................................................................... 27 

  • 8/16/2019 Nemo BTS Fileformat 1.15

    5/28

    BTS FILE FORMAT

    Page 5

    1  GENERAL STRUCTURE

    The first row of the file contains the keywords that define the order of the parameters in the

    following lines. Keywords are separated with semicolon (;) or tabulator character.

    Other rows in the file contain the cell definitions. Each line describes one cell and contains a set of

    parameters describing the cell as well as the site in which the cell resides. For both site and cell

    information, there are both mandatory parameters and optional parameters. Site and cell

    parameters are separated with semicolon or tabulator character.

    The file format supports three data types: integer, float and string. Integer type is defined as a

    numeric value without dot character. Float type is defined as a numeric value with dot character.

    String type is defined as a set of any printable ASCII characters except semicolon.

  • 8/16/2019 Nemo BTS Fileformat 1.15

    6/28

    BTS FILE FORMAT

    Page 6

    2  CREATING BTS FILES

    BTS files can be created, for example, with MS Excel. Type in the cell parameters and save the file

    in CSV format. After you have saved the as CSV, please check with Notepad (or with similar ASCII

    text editor) that your delimiter is either semicolon or tabulator. Also check that your coordinates

    have the period (.) character, for example 65.012345. Finally, change the file extension to .nbf.

  • 8/16/2019 Nemo BTS Fileformat 1.15

    7/28

    BTS FILE FORMAT

    Page 7

    3  PARAMETERS

    3.1  Mandatory cell parameters

    Parameter Keyword Type Description

    System SYSTEM String AMPS, GSM, TDMA, CDMA, UMTS,TETRA, TD-SCDMA, WIMAX, EVDOor LTE.

    Site Name SITE String Name of the site.

    Cell Name  CELL String Name of the cell.

    Latitude LAT Float Latitude of the site in degrees.

    Longitude LON Float Longitude of the site in degrees.

    Decimal degrees (DD) express latitude and longitude geographic coordinates as decimal fractions

    and are used in many Geographic Information Systems (GIS), web mapping applications such as

    Google Maps, and GPS devices. Decimal degrees are an alternative to using degrees, minutes, and

    seconds (DMS). As with latitude and longitude, the values are bounded by ±90° and ±180° each.

    Positive latitudes are north of the equator, negative latitudes are south of the equator. Positive

    longitudes are east of Prime Meridian, negative longitudes are west of the Prime Meridian. Latitude

    and longitude are usually expressed in that sequence, latitude before longitude.

    3.2  Optional cell parameters

      Note that BSIC number format and separator parameters are defined per BTS file, not per

    cell. If these two parameters are included in the BTS file, they must be located at the

    beginning of the file on separate rows. See example below.

    Parameter Keyword Type Description

    AntennaHeight

    HEIGHT Integer Values range from 0 to 1000

    Antenna Tilt TILT Float Values range from -90 to 90.

    AntennaBeam Width

    BEAM Integer Values range from 1 to 360

    AntennaIdentification

    ANTENNA_ID String Text

  • 8/16/2019 Nemo BTS Fileformat 1.15

    8/28

    BTS FILE FORMAT

    Page 8

    BSIC NumberFormat

    BSIC_NUMBER_FORMAT Integer Base Station Identity Code Format. Validvalues are: "OCT", "DEC", and "HEX",Case is insensitive. If this keyword is notspecified, “DEC” is used by default

    Cell Range RANGE Integer Cell range in meters.

    Cell Type TYPE String NORMAL, REPEATER, SMALL_CELL, orDAS

    Neighbor CellName

    NCELL_n String Unique identifier of the neighbor n.

    Separator SEPARATOR String SEPARATOR can be specified by theSEPARATOR keyword. If this keyword isnot specified, either ; or TAB character isused by default and it is determined fromthe parameter header line

    User-definedcolumn name

    User-defined name String Text

    Example:

    BSIC_NUMBER_FORMAT “OCT”

    SEPARATOR “;”

    SYSTEM;SITE;LAT;LON;CELL;CH;BSIC;CID;LAC;DIR;NCELL_1;NCELL_2;NCELL_3

    GSM;Site Name 1;65.066053;25.458366;Cell Name 1;64;77;12500;65231;0;NEMO1;NEMO2;NEMO3

    GSM;Site Name 1;65.066053;25.458366;Cell Name 2;41;42;12501;5231;90;NEMO5;NEMO6;NEMO7

    GSM;Site Name 1;65.066053;25.458366;Cell Name 3;2;24;12502; 65231;45;NEMO8;NEMO9;NEMO10

  • 8/16/2019 Nemo BTS Fileformat 1.15

    9/28

    BTS FILE FORMAT

    Page 9

    3.3  AMPS cell parameters

    3.3.1  Mandatory parameters

    Parameter Keyword Type Description

    System SYSTEM String AMPS.

    Site Name SITE String Name of the site.

    Cell Name CELL String Name of the cell.

    ChannelNumber 

    CH Integer Channel number

    SAT SAT Integer Setup Audio Tone

    AntennaDirection 

    DIR Integer Values range from 0 to 360 degrees.

    3.3.2 

    Optional parameters

    Parameter Keyword Type Description

    AntennaHeight

    HEIGHT Integer Values range from 0 to 1000

    Antenna Tilt TILT Float Values range from -90 to 90.

    Antenna BeamWidth

    BEAM Integer Values range from 1 to 360

    Cell Range RANGE Integer Cell range in meters.

    Cell Type TYPE String NORMAL or REPEATER

    Neighbor CellName

    NCELL_n String Unique identifier of the neighbor n.

    User-definedcolumn name

    User-defined

    name

    String Text

    Example:

    SYSTEM;SITE;LAT;LON;CELL;CH;SAT;CID;DIR

    AMPS;Site Name 1;65.066053;25.458366;Cell Name 1;140;1;11503;45

    AMPS;Site Name 1;65.066053;25.458366;Cell Name 2;410;2;11501;90

    AMPS;Site Name 1;65.066053;25.458366;Cell Name 3;201;3;11504;230

  • 8/16/2019 Nemo BTS Fileformat 1.15

    10/28

    BTS FILE FORMAT

    Page 10

    3.3.3  Cell search method

    Lines are drawn from the current location on a map to the serving cell based on the following

    algorithm:

      Matching Channel + SAT

      Note that if multiple matching cells are found, closest cell is selected. The cell is matched

    only if distance is less than 50 km (31 miles).

  • 8/16/2019 Nemo BTS Fileformat 1.15

    11/28

    BTS FILE FORMAT

    Page 11

    3.4  GSM cell parameters

    3.4.1  Mandatory parameters

    Parameter Keyword Type Description

    System SYSTEM String GSM.

    Site Name SITE String Name of the site.

    Cell Name CELL String Unique identifier of the cell. If unique name for everycell is not available, concatenation of LAC and CI canbe used.

    ChannelNumber

    CH Integer ARFCN. Values range from 0 to 1024.

    BSIC BSIC Integer Base Station Identity Code in decimal format. Valuesrange from 0 to 63. If BSIC Number Format is octal orhex, values with octal range from 0 to 77. With hexvalues range from 0 to 3F.

    Cell ID CID Integer Cell identification. Values range from 0 to 65535.

    LAC LAC Integer Location Area Code. Values range from 0 to 65535.

    AntennaDirection

    DIR Integer Values range from 0 to 360 degrees.

    3.4.2 

    Optional parameters

    Parameter Keyword Type Description

    RAC RAC Integer Routing Area Code. Values range from 0 to 255.

    Antenna Height HEIGHT Integer Values range from 0 to 1000

    Antenna Tilt TILT Float Values range from -90 to 90.

    Antenna BeamWidth

    BEAM Integer Values range from 1 to 360

    Cell Range RANGE Integer Cell range in meters.

    Cell Type TYPE String NORMAL or REPEATER

    Neighbor CellName

    NCELL_n String Unique identifier of the neighbor n.

    User-definedcolumn name

    User-definedname

    String Text

  • 8/16/2019 Nemo BTS Fileformat 1.15

    12/28

    BTS FILE FORMAT

    Page 12

    Example:

    BSIC_NUMBER_FORMAT "OCT"

    SYSTEM;SITE;LAT;LON;CELL;CH;BSIC;CID;LAC;DIR;NCELL_1;NCELL_2;NCELL_3

    GSM;Site Name 1;65.066053;25.458366;Cell Name 1;64;1;12500;65231;0;NEMO1;NEMO2;NEMO3

    GSM;Site Name 1;65.066053;25.458366;Cell Name 2;41;1;12501; 65231;90;NEMO5;NEMO6;NEMO7

    GSM;Site Name 1;65.066053;25.458366;Cell Name 3;2;1;12502; 65231;45;NEMO8;NEMO9;NEMO10

    3.4.3  Cell search method

    Lines are drawn from the current location on a map to the serving cell and neighbor cells based on

    the following algorithm.

      Matching CellId + LAC

      Matching CellId + BCCH

      Matching BCCH Channel + BSIC (also for neighbor list and missing neighbors)

      Matching BCCH Channel (also for neighbor list and missing neighbors)

      Note that if multiple matching cells are found, closest cell is selected. The cell is matched

    only if distance is less than 50 km (31 miles).

  • 8/16/2019 Nemo BTS Fileformat 1.15

    13/28

    BTS FILE FORMAT

    Page 13

    3.5  CDMA cell parameters

    3.5.1  Mandatory parameters

    Parameter Keyword Type Description

    System SYSTEM String CDMA.

    Site Name SITE String Name of the site.

    Cell Name CELL String Name of the cell.

    Pilot Number PN Integer Values range from 0 to 10000.

    Channel CH Integer Channel

    AntennaDirection

    DIR Integer Values range from 0 to 360 degrees.

    3.5.2  Optional parameters

    Parameter Keyword Type Description

    System ID SID Integer System ID. SID presents international identificationand system number identifying the service area andfrequency block.

    Network ID NID Integer Network ID.

    Antenna

    Height

    HEIGHT Integer Values range from 0 to 1000

    Antenna Tilt TILT Float Values range from -90 to 90.

    Antenna BeamWidth

    BEAM Integer Values range from 1 to 360

    Cell Range RANGE Integer Cell range in meters.

    Cell Type TYPE String NORMAL or REPEATER

    Neighbor Cell

    Name

    NCELL_n String Unique identifier of the neighbor n.

    User-definedcolumn name

    User-definedname

    String Text

    Example:

    SYSTEM;SITE;LAT;LON;CELL;PN;CH;DIR

    CDMA;Site Name 1;65.066053;25.458366;Cell Name 1;171;150;90

    CDMA;Site Name 1;65.066053;25.458366;Cell Name 2;272;150;55

  • 8/16/2019 Nemo BTS Fileformat 1.15

    14/28

    BTS FILE FORMAT

    Page 14

    3.5.3  Cell search method

    Lines are drawn from the current location on a map to the active set and neighbor set cells based

    on the following algorithm.

      Matching Channel + Pilot

      Matching Pilot

      Note that if multiple matching cells are found, closest cell is selected. The cell is matched

    only if distance is less than 50 km (31 miles).

  • 8/16/2019 Nemo BTS Fileformat 1.15

    15/28

    BTS FILE FORMAT

    Page 15

    3.6  UMTS cell parameters

    3.6.1  Mandatory parameters with 28-bit cell ID

    Parameter Keyword Type Description

    System SYSTEM String UMTS.

    Site Name SITE String Name of the site.

    Cell Name CELL String Unique identifier of the cell. If unique name for every cellis not available, 28-bit cell ID can be used.

    ChannelNumber

    CH Integer UARFCN. Value ranges:

    UMTS 850, from 4357-4458,1007,1012,1032,1037,1062,1087

    UMTS 900, from 2935-3090

    UMTS 1900, from 9662-9938,412,437,462,487,512,537,562,587,612,637,662,687

    UMTS 2100, from 10550 to 10850.

    UMTS 2100 AWS, from 1535-1740,1887,1912,1937,1962,1987,2012,2037,2062,2087

    ScramblingCode

    SCR Integer Values range from 0 to 512.

    Cell ID CID Integer Cell ID. The 28-bit Cell Identity (“UC-Id” in 3GPP) is a

    Concatenation of RNC-ID and C-ID.

    AntennaDirection

    DIR Integer Values range from 0 to 360.

    3.6.2 

    Mandatory parameters with 16-bit cell ID and RNC ID

    Parameter Keyword Type Description

    System SYSTEM String UMTS.

    Site Name SITE String Name of the site.

    Cell Name CELL String Unique identifier of the cell. If unique name for every cellis not available, 28-bit cell ID can be used.

    ChannelNumber

    CH Integer UARFCN. Value ranges:

    UMTS 850, from 4357-4458,1007,1012,1032,1037,1062,1087

    UMTS 900, from 2935-3090

    UMTS 1900, from 9662-9938,412,437,462,487,512,537,562,587,612,637,662,687

    UMTS 2100, from 10550 to 10850.

    UMTS 2100 AWS, from 1535-1740,1887,1912,1937,1962,1987,2012,2037,2062,2087

  • 8/16/2019 Nemo BTS Fileformat 1.15

    16/28

    BTS FILE FORMAT

    Page 16

    ScramblingCode

    SCR Integer Values range from 0 to 512.

    Cell ID CID_16 Integer Cell ID. The 16-bit Cell Identity. C-ID.

    RNC ID RNCID Integer RNC ID. The 12- bit RNC identity. Cell-ID (28 bit) = RNC-ID (12 bit) + CI (16 bit).

    AntennaDirection

    DIR Integer Values range from 0 to 360.

      Note that cell ID must be given either in 28-bit (CID) or 16-bit format (CID_16)

    combined with 12-bit RNC ID (RNCID).

    3.6.3  Optional parameters

    Parameter Keyword Type Description

    LAC LAC Integer Location Area Code. Values range from 0 to 65535.

    RAC RAC Integer Routing Area Code. Values range from 0 to 255.

    URA URA Integer UTRAN Registration Area

    RNC ID RNCID Integer Radio Network Controller ID. Equal to the 12-bitRNCId in 3GPP TS 25.401, section 6.1.5. Integer,base 10 or (with prefix 0x) hexadecimalrepresentation.

    AntennaHeight

    HEIGHT Integer Values range from 0 to 1000

    Antenna Tilt TILT Float Values range from -90 to 90.

    Antenna BeamWidth

    BEAM Integer Values range from 1 to 360

    Cell Range RANGE Integer Cell range in meters.

    Cell Type TYPE String NORMAL or REPEATER

    Neighbor CellName

    NCELL_n String Unique identifier of the neighbor n.

    User-definedcolumn name

    User-definedname

    String Text

    Example with 28-bit cell ID:

    SYSTEM;SITE;LAT;LON;CELL;CH;BSIC;CID;SCR;DIR;NCELL_1;NCELL_2;NCELL_3

    UMTS;Site Name 1;65.066053;25.458366;Cell Name 1;10838;;123811;96;0;NEMO1;NEMO2;NEMO3

    UMTS;Site Name 1;65.066053;25.458366;Cell Name 2;10838;;123758;2;0;NEMO4;NEMO5;NEMO6

    UMTS;Site Name 1;65.056053;25.458366;Cell Name 3;10838;;123769;4;90;NEMO7;NEMO8;NEMO9

  • 8/16/2019 Nemo BTS Fileformat 1.15

    17/28

    BTS FILE FORMAT

    Page 17

    Example with 16-bit cell ID:

    SYSTEM;SITE;LAT;LON;CELL;CH;BSIC;CID_16;RNC_ID;SCR;DIR;NCELL_1;NCELL_2;NCELL_3

    UMTS;Site Name 1;65.066053;25.458366;Cell Name 1;10838;;58275;1;96;0;NEMO1;NEMO2;NEMO3

    UMTS;Site Name 1;65.066053;25.458366;Cell Name 2;10838;;58222;1;2;0;NEMO4;NEMO5;NEMO6

    UMTS;Site Name 1;65.056053;25.458366;Cell Name 3;10838;;58233;1;4;90;NEMO7;NEMO8;NEMO9

    3.6.4 

    Cell search method

    Lines are drawn from the current location on a map to the active set and monitored set cells based

    on the following algorithm.

      Matching Cell ID

      Matching Carrier + SCR (also for neighbor list and missing neighbors)

      Note that if multiple matching cells are found, closest cell is selected. The cell is matched

    only if distance is less than 50 km (31 miles).

    3.7  TETRA cell parameters

    3.7.1  Mandatory parameters

    Parameter Keyword Type Description

    System SYSTEM String TETRA.

    Site Name SITE String Name of the site.

    Cell Name CELL String Name of the cell.

    LAC LAC Integer Location Area Code. Values range from 0 to 16383.

    Main Carrier CH Integer Values range from 0 to 4095.

    FrequencyBand

    BAND Integer Values range from 0 to 15.

    AntennaDirection

    DIR Integer Values range from 0 to 360.

    3.7.2  Optional parameters

    Parameter Keyword Type Description

    AntennaHeight

    HEIGHT Integer Values range from 0 to 1000

    Antenna Tilt TILT Float Values range from -90 to 90.

    Antenna BeamWidth

    BEAM Integer Values range from 1 to 360

    Cell Range RANGE Integer Cell range in meters.

  • 8/16/2019 Nemo BTS Fileformat 1.15

    18/28

    BTS FILE FORMAT

    Page 18

    Cell Type TYPE String NORMAL or REPEATER

    Neighbor CellName

    NCELL_n String Unique identifier of the neighbor n.

    User-definedcolumn name

    User-definedname

    String Text

    Example:

    SYSTEM;SITE;LAT;LON;CELL;LAC;CH;BAND;DIR

    TETRA;Site Name 1;65.066053;25.458366;Cell Name 1;3652;124;3;90

    TETRA;Site Name 1;65.066053;25.458366;Cell Name 2;3613;125;3;45

    TETRA;Site Name 1;65.056053;25.458366;Cell Name 3;3622;68;3;0

    3.7.3 

    Cell search method

    Lines are drawn from the current location on a map to the serving cell and neighbor cells based on

    the following algorithm.

      Matching Channel + LAC + Band

      Note that if multiple matching cells are found, closest cell is selected. The cell is matched

    only if distance is less than 50 km (31 miles).

    3.8  TD-SCDMA cell parameters

    3.8.1 

    Mandatory parameters

    Parameter Keyword Type Description

    System SYSTEM String TDSCDMA or TD-SCDMA.

    Site Name SITE String Name of the site.

    Cell Name CELL String Name of the cell.

    ChannelNumber

    CH Integer Values range from 9504 to 10121.

    CellParameters Id

    CPID Integer Values range from 0 to 127.

    Cell ID CID Integer Cell ID (16- bit)

    AntennaDirection

    DIR Integer Values range from 0 to 360.

  • 8/16/2019 Nemo BTS Fileformat 1.15

    19/28

    BTS FILE FORMAT

    Page 19

    3.8.2  Optional parameters

    Parameter Keyword Type Description

    LAC LAC Integer Location Area Code. Values range from 0 to 65535.

    RAC RAC Integer Routing Area Code. Values range from 0 to 255.

    URA URA Integer UTRAN Registration Area

    RNC ID RNCID Integer Radio Network Controller ID

    AntennaHeight

    HEIGHT Integer Values range from 0 to 1000

    Antenna Tilt TILT Float Values range from -90 to 90.

    Antenna Beam

    Width

    BEAM Integer Values range from 1 to 360

    Cell Range RANGE Integer Cell range in meters.

    Cell Type TYPE String NORMAL or REPEATER

    Neighbor CellName

    NCELL_n String Unique identifier of the neighbor n.

    User-definedcolumn name

    User-definedname

    String Text

    Example:

    SYSTEM;SITE;LAT;LON;CELL;CH;BSIC;CID;CPID;DIR

    TDSCDMA;Site Name 1;65.066053;25.458366;Cell Name 1;10120;;;96;0

    TDSCDMA;Site Name 1;65.066053;25.458366;Cell Name 2;10120;;;2;30

    TDSCDMA;Site Name 1;65.056053;25.458366;Cell Name 3;10120;;;4;90

    3.8.3  Cell search method

    Lines are drawn from the current location on a map to the active set and monitored set cells based

    on the following algorithm.

      Matching Cell ID (16 bit)

      Matching Carrier + Cell Parameters Id (also for neighbor list)

      Note that if multiple matching cells are found, closest cell is selected. The cell is matched

    only if distance is less than 50 km (31 miles).

  • 8/16/2019 Nemo BTS Fileformat 1.15

    20/28

    BTS FILE FORMAT

    Page 20

    3.9  WIMAX cell parameters

    3.9.1  Mandatory parameters

    Parameter Keyword Type Description

    System SYSTEM String WIMAX.

    Site Name SITE String Name of the site.

    Cell Name CELL String Name of the cell.

    Frequency FREQ Float Frequency in MHz.

    PreambleIndex

    PI Integer Values range from 0 to 113.

    Antenna

    Direction

    DIR Integer Values range from 0 to 360.

    Base StationID

    BSID String Base Station ID. Six colon separated hex values indouble quotes.

    3.9.2  Optional parameters

    Parameter Keyword Type Description

    AntennaHeight

    HEIGHT Integer Values range from 0 to 1000

    Antenna Tilt TILT Float Values range from -90 to 90.

    Antenna BeamWidth

    BEAM Integer Values range from 1 to 360

    Cell Range RANGE Integer Cell range in meters.

    Cell Type TYPE String NORMAL or REPEATER

    Neighbor CellName

    NCELL_n String Unique identifier of the neighbor n.

    User-definedcolumn name User-definedname

    String Text

    Example:

    SYSTEM;SITE;LAT;LON;CELL;FREQ;PI;DIR;BSID

    WIMAX;Site Name 1;65.066053;25.458366;Cell Name 1;2550.000;67;90;03:0f:21:00:02:72

    WIMAX;Site Name 1;65.066053;25.458366;Cell Name 2;2550.000;68;180;03:0f:21:00:02:73

    WIMAX;Site Name 1;65.056053;25.458366;Cell Name 3;2550.000;69;270; 03:0f:21:00:02:74

  • 8/16/2019 Nemo BTS Fileformat 1.15

    21/28

    BTS FILE FORMAT

    Page 21

    3.9.3  Cell search method

    Lines are drawn from the current location on a map to the serving cell and neighbor cells based on

    the following algorithm.

      Base Station ID + Preamble index

      Frequency + Preamble index

      Note that if multiple matching cells are found, closest cell is selected. The cell is matched

    only if distance is less than 50 km (31 miles).

  • 8/16/2019 Nemo BTS Fileformat 1.15

    22/28

    BTS FILE FORMAT

    Page 22

    3.10  EVDO cell parameters

    3.10.1 Mandatory parameters

    Parameter Keyword Type Description

    System SYSTEM String EVDO.

    Site Name SITE String Name of the site.

    Cell Name CELL String Name of the cell.

    Pilot Number PN Integer Values range from 0 to 10000.

    Channel CH Integer Channel

    AntennaDirection

    DIR Integer Values range from 0 to 360 degrees.

    3.10.2 Optional parameters

    Parameter Keyword Type Description

    System ID SID Integer System ID. SID presents international identificationand system number identifying the service area andfrequency block.

    Network ID NID Integer Network ID.

    Antenna

    Height

    HEIGHT Integer Values range from 0 to 1000

    Antenna Tilt TILT Float Values range from -90 to 90.

    Antenna BeamWidth

    BEAM Integer Values range from 1 to 360

    Cell Range RANGE Integer Cell range in meters.

    Cell Type TYPE String NORMAL or REPEATER

    Neighbor Cell

    Name

    NCELL_n String Unique identifier of the neighbor n.

    User-definedcolumn name

    User-definedname

    String Text

    Example:

    SYSTEM;SITE;LAT;LON;CELL;PN;CH;DIR

    EVDO;Site Name 1;65.066053;25.458366;Cell Name 1;171;150;90

    EVDO;Site Name 1;65.066053;25.458366;Cell Name 2;272;150;55

  • 8/16/2019 Nemo BTS Fileformat 1.15

    23/28

    BTS FILE FORMAT

    Page 23

    3.10.3 Cell search method

    Lines are drawn from the current location on a map to the active set and neighbor set cells based

    on the following algorithm.

      Matching Channel + Pilot

      Matching Pilot

      Note that if multiple matching cells are found, the closest cell is selected. The cell is

    matched only if distance is less than 50 km (31 miles).

  • 8/16/2019 Nemo BTS Fileformat 1.15

    24/28

    BTS FILE FORMAT

    Page 24

    3.11  LTE cell parameters

    3.11.1 Mandatory parameters

    Parameter Keyword Type Description

    System SYSTEM String LTE

    Site Name SITE String Name of the site.

    Cell Name CELL String Unique identifier of the cell. If there is no uniquename available for every cell, Cell ID (CID) can beused

    ChannelNumber

    CH Integer EARFCN number. Values range from 0 to 65535

    Cell ID CID Integer Cell identificationCell identification of the current cell.Range: 0 – 268435455

    Physical LayerCell ID

    PCI Integer Values range from 0 to 503.

    AntennaDirection

    DIR Integer Values range from 0 to 360.

    3.11.2 Optional parameters

    Parameter Keyword Type Description

    TAC TAC Integer Tracking area codeTracking area code of the currently used cell. See3GPP TS 124.301 subclause 9.9.3.32.Range: 0 – 65535

    AntennaHeight

    HEIGHT Integer Values range from 0 to 1000

    Antenna Tilt TILT Float Values range from -90 to 90.

    Antenna Beam

    Width

    BEAM Integer Values range from 1 to 360

    Cell Range RANGE Integer Cell range in meters.

    Cell Type TYPE String NORMAL or REPEATER

    Neighbor CellName

    NCELL_n String Unique identifier of the neighbor n.

    User-definedcolumn name

    User-definedname

    String Text

  • 8/16/2019 Nemo BTS Fileformat 1.15

    25/28

    BTS FILE FORMAT

    Page 25

    Example:

    SYSTEM;SITE;LAT;LON;CELL;CH;CID;PCI;DIR;NCELL_1;NCELL_2;NCELL_3

    LTE;Site Name 1;65.066053;25.458366;Cell Name

    1;65535;26842545;96;0;NEMO1;NEMO2;NEMO3

    LTE;Site Name 1;65.066053;25.458366;Cell Name 2;65535;26841545;2;0;NEMO4;NEMO5;NEMO6

    LTE;Site Name 1;65.056053;25.458366;Cell Name

    3;65535;26844545;4;90;NEMO7;NEMO8;NEMO9

    3.11.3 Cell search method

    Lines are drawn from the current location on a map to the active set and monitored set cells based

    on the following algorithm.

    Cell Identification (Cell ID) (for serving cell)

    Matching Channel number + Physical Layer Cell ID (for both serving and neighbor cells)

  • 8/16/2019 Nemo BTS Fileformat 1.15

    26/28

    BTS FILE FORMAT

    Page 26

    3.12  IDEN cell parameters

    3.12.1 Mandatory parameters

    Parameter Keyword Type Description

    System SYSTEM String IDEN

    Site Name SITE String Name of the site.

    Cell Name CELL String Unique identifier of the cell. If unique name for everycell is not available, concatenation of CH and CC canbe used.

    ChannelNumber

    CH Integer Values range from 1 to 1200.

    Color Code CC Integer Color codeRange: 0 – 15

    AntennaDirection

    DIR Integer Values range from 0 to 360 degrees.

    3.12.2 Optional parameters

    Parameter Keyword Type Description

    Antenna Height HEIGHT Integer Values range from 0 to 1000

    Antenna Tilt TILT Float Values range from -90 to 90.

    Antenna BeamWidth

    BEAM Integer Values range from 1 to 360

    Cell Range RANGE Integer Cell range in meters.

    Cell Type TYPE String NORMAL or REPEATER

    Neighbor CellName

    NCELL_n String Unique identifier of the neighbor n.

    User-definedcolumn name User-definedname

    String Text

    3.12.3 

    Cell search method

    Lines are drawn from the current location on a map to the active set and monitored set cells based

    on the following algorithm.

      Matching channel number + color code (for both serving and neighbor cells)

      Note that if multiple matching cells are found, the closest cell is selected. The cell is

    matched only if distance is less than 50 km (31 miles).

  • 8/16/2019 Nemo BTS Fileformat 1.15

    27/28

    BTS FILE FORMAT

    Page 27

    4  TECHNICAL SUPPORT

    If you have questions on or beyond this documentation about Nemo tools, please contact our

    technical support service through Nemo Support Portal at http://nemosupport.anite.com, call us

    (local phone numbers can be found in chapter Phone and Email Support) or send us an email at

    [email protected]. Note that for full support you need to have the Maintenance Agreement.

    4.1  User Club

    Nemo User Club offers several new ways to benefit from Nemo products. You can find it from

    http://nemouserclub.anite.com.

    Access to the Nemo User Club is restricted to customers with SW maintenance and

    Technical Support agreements or partner agreements. If you are an existing Anite Network

    Testing customer with SW maintenance and Technical Support agreements, but you are without

    access to the User Club, please complete an on-line registration form.

    After submitting the requested information, you will receive a personal access key and password by

    email in a few days time.

    Once you are registered with our User Club, you will a u t o m a t i c a l l y   receive e-mails informing you

    each time a new version of software for your Nemo Product is released. It is fast, easy, and it is

    available to you seven days a week, 24 hours a day.

    4.2  Nemo Support Portal

    Nemo Support Portal is a web interface for technical support, product-related questions, and RMA

    requests. It offers a fast and convenient way to reach our technical support team and submit repair,

    warranty repair, and calibration requests. Customers can open a support ticket, follow the status of

    existing tickets, and request technical support 24/7/365. Furthermore the Nemo Support Portal

    includes a Knowledge Base for the most frequent and latest topics on Nemo Products. Submitting a

    ticket via Nemo Support Portal ensures that our technical specialists have all the necessary

    information available to solve your support case, resulting in faster response times.

    Please go to http://nemosupport.anite.com to access the portal and click “Request access” to obtain

    a password to the system.

    4.3  Phone and Email Support

    During the warranty period, the phone support related to potential software errors is free of

    additional charge. Registered users with a valid Maintenance Agreement are entitled to full support.

    Nemo Support Portal is the preferred channel for technical support requests, but you can also send

    us an email. When emailing, please let us know the number of your Software Maintenance and

    Support Agreement.

  • 8/16/2019 Nemo BTS Fileformat 1.15

    28/28

    BTS FILE FORMAT

    Please contact us at the following locations:

    Global

    Mobile +358 50 395 7800

    Americas

    Mobile +1 469 951 9105

    +1 469 774 4608 (En español eportuguês)

    APAC

    Tel. +65 9746 2431

    P.R. China

    Tel. +86 10 6567 8528

    India

    Tel. +91 982 0016372

    Middle East

    Tel. +86 10 6567 8528

    P.R. China

    Tel. +97 155 620 4132