Net Access display of PACS Radiology Images Page 1 of 11 Select a patient on NetAccess Select Results from the NetAccess Navigator located in left of the screen.

Net Access display of PACS Radiology Images · PDF fileNet Access display of PACS Radiology Images Page 3 of 11 If this is the first time that PACS CareStream has been accessed from

  • Upload
    dodieu

  • View
    224

  • Download
    5

Embed Size (px)

Citation preview

Net Access display of PACS Radiology Images

Page 1 of 11

Select a patient on NetAccess

Select Results from the NetAccess Navigator located in left of the screen.

Net Access display of PACS Radiology Images

Page 2 of 11

Select Results from the NetAccess Navigator located in left of the screen. Then select Rad All.

Select the View Icon next to the image report

Net Access display of PACS Radiology Images

Page 3 of 11

If this is the first time that PACS CareStream has been accessed from the workstation then the prompt to install the supporting software will display. Select Install. Then select yes when the prompt asking if you want to trust date from Algotec Systems.

Net Access display of PACS Radiology Images

Page 4 of 11

NetAccess and CareStream PACS each require a different version of Java to function properly. Because of the conflict select yes to the prompt to start a new Java session.

The CareStream URL containing the user logon, password, patient account, selected study accession number, and other parameters is passed from Net Access to CareStream when the View Icon is selected. The clinician is seamlessly logged onto CareStream. The selected image, report, and order information as well as the Patient Mini Archive containing images, reports, and order info from 5/15/07 forward can be viewed.

Net Access display of PACS Radiology Images

Page 5 of 11

The following screen will appear while the URL activation to CareStream is processing. This should take less than 30 seconds.

The image of procedure selected from NetAccess is displayed (Note: due to test environment limitations the test procedure selected and image may not match).

Net Access display of PACS Radiology Images

Page 6 of 11

Though the image or images for the procedure selected in NetAccess are displayed when the user logs on to CareStream other procedures that have been performed on the patient from May 15, 2007 forward will be available for the clinician to view in the Patient Mini Archive (PMA).

This study has 5 associated images

The Result Report can be viewed by selecting the R from the Mini Archive

or the Reports button.

The Order can be viewed by selecting the O

Patient Mini Archive

Net Access display of PACS Radiology Images

Page 7 of 11

The Result Report will open in a new browser window. It is very important to teach users to exit this window by selecting File/Close or the X. If the user minimizes the window it will remain open (even after the user logs off of NetAccess).

If the user selects the X in the Carestream window when attempting to close the report they will be logged out of CareStream but the report will remain open.

The Order information will open in a new browser window. It is very important to teach users to exit this window by selecting File/Close or the X. If the user minimizes the window it will remain open (even after the user logs off of NetAccess).

If the user selects the X in the Carestream window when attempting to close the report they will be logged out of CareStream but the report will remain open.

For confidentiality reasons the user should never print or save the report to file or disk.

Net Access display of PACS Radiology Images

Page 8 of 11

Note that the Order display window was not closed properly. The Order window was minimized. Therefore three browser windows are open in the task bar. A window for NetAccess, CareStream, and the Order are open.

When the user returns to NetAccess from CareStream PACS the Java Plug-in error is displayed in the data well due to the existing browser conflict.

Note that if the user minimized the CareStream window and did not exit properly the window for CareStream remains open. In this example the user also minimized the order display resulting in three open browser windows in the task bar.

Net Access display of PACS Radiology Images

Page 9 of 11

Note if the user logs out of NetAccess and has not closed the CareStream windows correctly then the browser windows remain open in the task bar.

Net Access display of PACS Radiology Images

Page 10 of 11

Note even though the user is not log on to NetAccess or CareStream the orphan windows can be displayed. It is critical to be sure that users understand the importance of closing the windows properly.

Net Access display of PACS Radiology Images

Page 11 of 11

If the user attempts to view another image for the same patient or different patient from NetAccess and did not properly close the previous CareStream session the above message will appear. Select okay and the message box will close.

Some Radiology Procedures will not have images associated with them. Special Procedures, Sagital Corneal Reconstructive Procedures, and Fluoroscopy procedures are frequently combined with a primary report. The result report and image are associated with primary report noted in the result text. The user will see the text box above when this occurs. Inform the user to select ok and then read the report on NetAccess to determine the primary report and image.