Dear Customer, Thank you for giving us the honor to serve you through our innovative product/s. We take this opportunity to express extreme happiness to append our esteemed customer list with your concern. All our products are delicately planned, designed and developed with combined dedicated efforts by our team that includes biomedical engineers, designers, doctors and other expertise to bring forth the latest technology to satisfy the ever changing needs of our customer. Immaterial to the size and location of the organization/hospital/clinic we never ever take chance to loose our customer who is a valid gem. With experience of more than a decade, we understand that the height of success is possible to be achieved only through “CUSTOMER SATISFACTION”, which we have almost achieved irrespective of sustained highly competitive market through our hi-tech quality products & regular customer survey. We at Maestros strengthen our tender relationship with our customer by providing the best of the best services right from installation, servicing and regular maintenance. With our wide spread channels in all major cities of the subcontinent, we update our customer with our new range of products developed from time to time*. We would appreciate your valuable time to go through our other range of products that include ECG machines, Pulse Oximeters, Spirometers, Physiological monitors & Fetal monitors. We have also acquired competency in the development of PC based monitoring systems like Central Nursing Station, Stress Test System and PC based ECG machine. We proudly acknowledge you that we have also designed and developed and launched recently, state of art telemedicine products like VitalTrack, Lotus-700 & Lotus-500, Event Recorder ER 5, Telespiro, CardioAssist, Coddle Assist, Electronic Stethoscope and many more under stream of production. We welcome your complaints/compliments/orders/suggestions to improve our products at:

Maestros Mediline Systems Limited

Registered Office EL 63, TTC Industrial Area, Electronic Zone, Mahape, Navi Mumbai – 400 701

Phone: +91 022-27611311 Fax: +91 022- 27622153 Email: [email protected] Visit us: www.medi-line.com

* For latest updates visit our website regularly.

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 3: New Coddle Graph Single User Manual

Table of contents

INTRODUCTION........................................................................................1

PHYSICAL FEATURES................................................................................2 Figure 1.1 Front panel of the system.......................................................................................... 2 Figure 1.2 Encoder knob ........................................................................................................... 3

SIDE PANELS ................................................................................................................................. 4 Figure 1.3 Right hand side of the system.................................................................................... 4 Figure 1.4 Left hand side of the system ...................................................................................... 4

DISPLAY SCREEN........................................................................................................................... 5 Figure 1.5 Display screen.......................................................................................................... 5

PRINCIPLE OF OPERATION ......................................................................7 Figure 2.1 Principle of operation............................................................................................... 7

INSTALLATION.........................................................................................8 TO OPERATE ON MAINS ................................................................................................................. 8 TO OPERATE ON INBUILT BATTERY................................................................................................ 8 PARAMETER SETTINGS .................................................................................................................. 9 FETAL AND MOTHER MENU ............................................................................................................ 9

Figure 3.1 Fetal & mother menu................................................................................................ 9 SYSTEMS SETUP MENU .................................................................................................................. 9

Figure 3.2 System setup menu.................................................................................................. 10 PRINTER CONTROL MENU ............................................................................................................ 10

Figure 3.3 Printer control menu .............................................................................................. 10 RECHARGING THE INBUILT BATTERY.....................................................12

LOW BATTERY INDICATION ......................................................................................................... 12 PRINTER COMPARTMENT........................................................................13

Figure 4.1 Printer compartment .............................................................................................. 13 LOADING PAPER .......................................................................................................................... 13 PRINTING DURING MONITORING................................................................................................. 14 PRINTING DURING OFFLINE ........................................................................................................ 14 CONTROLLING THE VOLUME OF FETAL HEART SOUNDS............................................................... 14

ALARM INDICATIONS.............................................................................14 VISUAL INDICATIONS.................................................................................................................. 14 AUDIO INDICATIONS................................................................................................................... 14

NON STRESS TEST (NST) IN ANTENATAL PERIOD ..................................15

CONTRACTION STRESS TEST (CST) IN INTRAPARTUM PERIOD..............15

FETAL ACOUSTIC STIMULATION TEST (FAST) ........................................16 TROUBLESHOOTINGS .............................................................................17

WARNING MESSAGES.............................................................................18 FHR ALM ................................................................................................................................... 18 PRT ALM F ................................................................................................................................ 18 PRT ALM B................................................................................................................................ 18 PRT ALM 7 ................................................................................................................................ 18 OVER ......................................................................................................................................... 18

MAINTENANCE SCHEDULE......................................................................19 BATTERY MAINTENANCE .............................................................................................................. 19 STORAGE .................................................................................................................................... 20 PACKING / TRANSPORT .............................................................................................................. 20

TECHNICAL SPECIFICATIONS.................................................................21

WARRANTY ............................................................................................22

APPENDIX ..............................................................................................23

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 4: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 1

Introduction New CoddleGraph, state-of-the-art portable fetal monitor from Maestros is used in Obstetrics procedures for conduction of NST (Non Stress Test) in the ante-natal period and CST (Contraction Stress Test) during intrapartum monitoring. Features:

• Light and compact design, simple to use front panel controls • The color CSTN 5.7” 320X240 LCD displays the FHR, UA

curves and the monitoring states. The LCD panel tilted angle can be adjusted within 90 degrees.

• The system setup can be done very easy at any time and can be stored automatically

• A standard patient event marker and a clinical event marking button to separately mark clinical events

• Auto fetal movement • Multi-crystals, wide beam form, high sensitivity ultrasound

transducer, 1MHz pulsed wave, low ultrasound power, safer to the fetal

• AC or LI-battery operated • More than 10 hours data storage, they can be played and

reprinted • Advanced DSP technology, accurate and reliable • Zero noise processing, no undesired sound in the speaker • Top lights flash synchronizing with heart beating • 3 in 1 transducers, no cable intertwisting

DO NOT use CoddleGraph for: Ø Underwater monitoring during labor or delivery Ø Prolonged periods of time unless clinically indicated-typically

antenatal tests can give a trace sufficient for interpretation in 20 to 30 minutes or less

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 5: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 2

Physical features

Figure 1.1 Front panel of the system

1. Power ON/OFF 2. Display screen 3. Encoder knob 4. Printer compartment ▲ To increase the volume of the speaker. When at freeze state,

It can be used to review the stored data backward ▼ To decrease the volume of the speaker. When at freeze

state, It can be used to review the stored data forward.

To freeze the trace

Set the uterine pressure value to the preset value. This key is often as soon as the monitor is switched ON

If a drug is administered or some other event is required to be noted on the trace , the expert/nurse can press this key

Press this key at any time to print and press it again to stop printing

Audio alarm mute key

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 6: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 3

NOTE: Encoder knob provides user interaction with the display and the monitor functions. Rotating and depressing the encoder allows user to navigate, make changes to the display elements and monitor functions.

NOTE: MARKER mark is printed on the top of the FHR scale. Each time, the button is pressed down to mark timing of fetal movement, contractions or other events felt by the patient.

Rotate

Figure 1.2 Encoder knob

1. Encoder knob is used to interact with the appropriate area on the display screen

2. The procedure is the same for all the operational & display

changes a. Rotate the encoder until the Purple box encircles the

desired menu

b. Depress the encoder to select

c. Rotate the encoder knob either clockwise or anticlockwise for selecting the desired sub menu

The encoder knob is used to select the required options from the various menus.

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 7: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 4

Side panels

Figure 1.3 Right hand side of the system

Figure 1.4 Left hand side of the system

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 8: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 5

Display screen

Figure 1.5 Display screen Graphical area The LCD displays the FHR1 and TOCO, date, time, recorder state, recording speed, display state, display speed, volume, alarm state, remote marker, clinical marker and TOCO reference value. The upper one indicates the high threshold is 160 bpm (Beat per Minute) and the lower one indicates low threshold is 120 bpm. The toco range 0 to 100. At this menu, we can set the system parameters according to the key specifications above.

Numeric area is illustrated as below:

FHR1 The fetal heart rate is displayed in (bpm) beats per minute. In the absence of a signal (or with a signal of poor quality) the display reads ’---’

The speaker volume, there are eight levels marked from 0 to 7.

It means the FHR alarm function is enabled

TOCO (10) Relative strength of uterine activity. 0~100 is displayed Reference value of uterine activity, five levels are available, they are 0,5,10,15,20

FM This is the fetal movement counting value, the movements within 5 seconds are regarded as 1 time.

X4 It means the LCD display traces speed, four choices:X1, X2, X4, X8 the fastest speed display 4 points per second.

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 9: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 6

The system area is at the downright area: 13070701: The Pregnant Woman ID, the system can produce one new ID automatically when the monitor is switched ON and this ID can be changed during monitoring, and has effect on the data after ID change. If alarm happens, this place will display the alarm reasons. If the FHR alarm is enabled and happened, it will display FHR ALM. If no paper or the printer panel open or failures with the printer, it will display PRT ALARM. If monitoring time length is set, when the time is over, it will display TIME OVER. (Refer warning Messages) Date/time: The monitoring date and time for real-time or the stored working date & time in freeze state. (YY/MM/DD format) PRINT SPEED: The selected printer working speed, is also displayed Choices: 1, 2 and 3 (unit: cm/min) POWER SOURCE: It will display the AC (Plug icon) or DC (battery) icon according to the working power source.

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 10: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 7

Principle of operation CoddleGraph-D uses the proven technique of autocorrelation for calculating fetal heart rate. This method gives an accurate display of heart rate by eliminating any spurious signals. This is done by the use of Doppler principle of Ultrasound which states that –“Frequency of sound waves shifts as the source moves relative to the receiver” High frequency ultrasound waves (2MHz) are transmitted by placing the Doppler/ Ultrasound transducer over the abdomen of the patient. A coupling medium like jelly is used between the transducer and the abdomen to exclude any air from the interface so as to have minimal attenuation of the ultrasound signal. The reflected ultrasound waves are sensed by receiving crystals. When the fetal heart wall moves, the frequency of the reflected ultrasound changes and this change is known as Doppler shift. With every heart cycle, the heart wall moves twice and hence twice there is a Doppler shift. This signal is electronically processed to find the fetal heart rate, which is displayed. The Doppler shift signal is in the audio range and hence can also be heard.

Figure 2.1 Principle of operation For long term (Labour) monitoring, the uterine activity is monitored and recorded in terms of relative indication of the labour intensity by means of an external transducer known as Toco/UA-Transducer. The toco transducer is a spring-loaded displacement transducer, which is placed over the fundus where the contractions are maximum. During uterine contractions, the pressure signal is converted into an electrical signal to get the uterine activity, which is then plotted, on the recorder along with the heart rate.

Transmitter

Analog Circuit

Receiver Speaker Fetus

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 11: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 8

Installation • Initially, check the earthing in the mains switch, which may

result in a noisy tracings • Connect the 3 in 1 transducer • Plug in the adaptor • Switch ON the power supply • Make the desired parameter settings This completes the installation procedure and CoddleGraph is now ready to be used.

To operate on mains

• Connect the adaptor to the mains power supply on the wall

• Switch ON the power ON/OFF switch

• The system is now ready to operate on mains

• This is indicated on the screen with a symbol

To operate on inbuilt battery New CoddleGraph is powered by an internal rechargeable battery pack that provides 2 hours (with out printing) of recording when fully charged battery.

• Switch ON the system without connecting to the power supply; the system automatically works on inbuilt battery.

• This is indicated on the screen with Battery icon NOTE: In condition of power failure the system automatically switches to The battery mode & will switch back to mains when power supply resumes.

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 12: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 9

Parameter settings

Fetal and mother menu

Figure 3.1 Fetal & mother menu

1. ALM HI_LIMIT: The FHR alarm upper limit, there are 4 levels: 160,170,180,190(unit bpm)

2. ALM LO_LIMIT: The FHR alarm lower limit, there are 4 levels: 90,100,110,120(unit bpm)

3. ALM MUTE: The time in minutes for audio alarm mute can be set from here by the user as desired. The counter starts decreasing displayed on the screen once the time elapses the audio alarm starts sounding (if ON).

4. ALM ENABLE: ON or OFF means enable or disable the alarm function.

5. TOCO REFERENCE: The toco reference value, it can be set with 0,5,10,15,20

6. PREGNANT ID: Patient ID can be changed from here 7. GESTATION AGE: User can input the pregnant woman gestation

age.

Systems setup menu DATE/TIME: The real date and time of monitoring can be set by the user as desired (YY/MM/DD) format PRINTER CONTROL: Change the printer configuration refer printer control menu

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 13: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 10

MONITORING TIME LEN: This is used to set monitoring time length, when the time is over, the audio alarm sounds and stops monitoring the patient

Figure 3.2 System setup menu DISPLAY SPEED: 4 levels can be adjustable i.e. X1 X2, X4 and X8. The selected speed is displayed the screen DISPLAY MODE: 2 modes available, monitoring mode or demo mode. CONTRAST: The LCD contrast for good display effect selected by the user as desired POWER OFF: This is used to set the monitor working time, when the time is over, the system will be switched OFF automatically.

Printer control menu

Figure 3.3 Printer control menu PRT SPEED: This can be set with 1, 2, 3 cm/min

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 14: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 11

PRT DENSITY: This is used increased or decreased to a suitable printing effect. TOCO 0 PRT POSITION: This is used for toco 0 printing position on the paper. TOCO 100 PRT POSITION: This is used for toco 100 printing position on the paper. FHR 90 PRT POSITION: This is used for FHR 90 printing position on the paper. FHR 210 PRT POSITION: This is used for FHR 2109 printing position on the paper. WARNING: Each time CoddleGraph is used, check the alarm settings limits and parameter settings to ensure that they are appropriate for the patient being monitored.

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 15: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 12

Recharging the inbuilt battery Inbuilt battery can be charged online or offline as required by the user. The battery gets automatically charged whenever New CoddleGraph is switched ON the mains supply. Complete charging of the inbuilt batteries takes 3 hours and can operate for a minimum time period of 2 hours (without printing).

Low battery indication When the battery is low the battery icon will be displayed empty The empty battery icon starts toggling for 10 times and then monitor switches OFF automatically. WARNING: Do not allow the batteries to completely discharge for it may damage the equipment.

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 16: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 13

Printer compartment New CoddleGraph has inbuilt printer that requires Z fold thermal paper. Refer Parameter settings for printer settings. To open the printer compartment first unlock the printer lock by pushing it towards the display screen the printer flap opens. Pull the printer flap out the printer can be seen that is fitted on top as shown in the figure below.

Figure 4.1 Printer compartment

Loading paper

a. On opening the printer compartment place the Z fold paper in the space provided

b. Roll out a part of the paper on the printer flap and close the printer flap

c. Then lock the printer lock This completes the procedure of loading paper in the printer.

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 17: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 14

Printing during monitoring

• All the traces can be printed on a single page using the Print key on the front panel

• Printing will start from the point when the Print key is used • While printing PRINT… message appears on the screen • Printing will continue until the Print key is used again

Printing during offline The stored data can be printed when ever the user desires as follows:

• Freeze the screen using the freeze key on the key pad • To scroll the data backward use the UP key and DOWN key to

move forward in the stored data • Then press print key to start printing the desired stored

patient data • While printing PRINT… message appears on the screen • Printing will continue until the Print key is used again

Controlling the volume of fetal heart sounds Any instant of time the volume of the fetal heart sound can be increased or decreased using the UP/DOWN arrow keys respectively.

Alarm indications The new CoddleGraph has audio alarm indication and draws the user’s attention to patient or instrument condition that warrant immediate attention.

Visual indications Whenever the high or low alarm limits for fetal heart rate are above or below the set values the visual alarm is needed on the top lights on the LCD.

Audio indications Whenever the high or low alarm limits for fetal heart rate UA are above or below the set values the audio alarm sounds (if ON) Bell icon appears on the screen as well as in the print out (If printing is ON).

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 18: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 15

The volume intensity of the audio alarm can be increased or decreased by the user using the UP/DOWN arrow keys respectively. WARNING: Do not silence the audible alarm or decrease its volume, patient safety could be compromised.

Non Stress Test (NST) in antenatal period The NST is one way of externally monitoring the fetus. NST can be done as early as the 27th week of pregnancy, and it measures the FHR accelerations with normal movement. § Fetal heart is located on the surface of the maternal abdomen

§ Ultrasound jelly is applied on the Doppler transducer

§ The Doppler transducer is then placed on the abdomen where

maximum fetal heart sounds can be heard § Doppler transducer is secured onto the abdomen using the

elastic belt § Patient marker switch connected and the patient is instructed

to press the same when the fetal movement is felt. § Printout of the CTG waveform can be obtained

IMPORTANT: Place the entire probe face in contact with the skin surface to get good results.

NOTE: The Toco or the UA transducer is not used while conducting a NST.

Contraction Stress Test (CST) in intrapartum period

The CST is a final method of externally monitoring the fetus. This test measures the ability of the placenta to adequately oxygenate the fetus under pressure (contractions).

NOTE: Muting the audio alarms does not affect the visual alarm indications.

NOTE: Visual alarm indicators cannot be suspended or removed. Audible volume alarms may be decreased, increased or can be muted or put OFF as desired.

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 19: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 16

Same procedure is followed as above fro NST with addition steps mentioned below § Toco transducer is placed on the fundus( i.e. part of the womb

where maximum contraction is felt) § Printouts of the CTG and the UA waveform can be obtained

Fetal Acoustic Stimulation Test (FAST) Acoustic stimulation is performed to elicit acceleration of the fetal heart rate

§ Explain procedure to patient

§ Apply the acoustic stimulator to the maternal abdomen

§ Depress the button on the stimulator to emit sound interpreted in the context of the entire clinical picture

§ Observe for fetal response

§ If no acceleration is noted, repeat the procedure

§ Procedure may be repeated three times if no accelerations are noted

§ After these attempts, provide a period of rest to avoid a fetal habituation response to the stimulus

§ Document the procedure and fetal and maternal responses in the patient’s record

NOTE: The use of water based gel supplied by certificated suppliers is strongly recommended. Oil based gels can damage the transducer and must not be used. The use of oil based gels will invalidate your warranty.

NOTE: Do not use jelly on the Toco or the UA transducer.

IMPORTANT: Before starting, execute the UA Ref function in order to nullify the pressure due to the belt.

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 20: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 17

Troubleshootings

Problem Likely cause Corrective action

§ No power supply § Check for the power supply

§ Mains switch OFF § Switch ON the mains supply

No response / system does not turn ON

§ ON/OFF switch OFF § Switch ON the ON/OFF switch

No response on connecting to the mains

§ Power cable faulty § Replace the cable

No fetal heart sounds

§ FHR volume control decreased completely

§ Adjust the FHR volume as desired

No audio alarms

§ Volume control is completely decreased in the parameter settings

§ Adjust the volume control as desired in the parameter settings

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 21: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 18

Warning messages An warning message will be displayed in place of PATIENT ID when a malfunction is detected that prevents further use of the monitor until the malfunction is corrected

FHR ALM This message appears when the FHR1 is high or low to the set values. This message disappears once the readings come back to normal.

PRT ALM F This message appears when the printer flap is open or not closed properly and disappears on closing the printer flap properly.

PRT ALM B This message appears when the paper in the printer is exhausted and disappears when paper is loaded in the printer compartment (Refer Loading paper section).

PRT ALM 7 This message appears when the printer lock is not locked properly and locking the printer lock this message disappears.

OVER When ever the set monitoring length is over this message appears in the screen follow the instructions on the screen.

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 22: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 19

Maintenance schedule New CoddleGraph is extremely user friendly and with no routine service other than cleaning, battery maintenance and recharging, and that, which is mandated by the user’s institution. For better performance, operation and safety, regular routine maintenance is to be performed by the end user. ü Look for the standard power supply as specified in the technical

specifications before getting started ü Check for the proper connection of cables / transducers

ü Check for the proper functioning of the 3 in 1 transducer

ü Ensure for the fully charged battery while using on battery

ü Clean the panel /cables/ transducers with dry damp smooth cloth

ü Do not expose the device to either extreme temperatures, humidity, dust or direct sunlight

ü Make sure to service the system once in a year by an authorized

and fully trained engineer for proper functioning and trouble free operation of the system

NOTE: Maintain the records of maintenance, repair, and required updates of equipment.

Battery maintenance If the New CoddleGraph has not been used for a one month, the battery needs charging. To charge the battery refers inbuilt battery charging section. CAUTION: If the CoddleGraph is to be stored for a period of 2 months or longer, notify service personnel to remove the battery prior to storage

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 23: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 20

Cleaning

• Do not immerse the system into caustic or abrasive cleaners

• Unplug the 3 in 1 transducer from the system before cleaning or disinfecting

• Clean or disinfect the 3 in 1 transducer before attaching to a new

patient

• Clean the monitor and the cables with dry damp smooth cloth

• Do not use rough and sharp instrument to clean the cable and the sensors

NOTE: Make sure that the system is completely OFF while cleaning any part. CAUTION: Phenolic or antiseptic solutions such as Steriscol or Hibiscrub should never be used on any part of the system as these chemicals are known to spoil the quality of the product.

Storage While storing New CoddleGraph, make sure that the system is switched OFF completely and preferably disconnect all the cables. Storing the system for long period of time without charging the battery may degrade the battery capacity. Store in the system in as per the specifications provided.

Packing / Transport If available, use the original carton and packing materials (if not available use suitable carton)

• Disconnect all the cables

• Make sure that the system is completely turned OFF

• Fill the bottom of the carton with at least two inches of packing material

• After packing the system fill the box with packing material

• Make sure to mark the UP positioning of the system that if original carton is not used

• Make sure to seal the carton with packing tape

• Ensure to write the return address

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 24: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 21

Technical specifications

Ultrasound Transducer Pulsed Doppler Frequency 1 MHz Measurement range 50 to 210 bpm Resolution 1 bpm Intensity < 10m W/sq cm High alarm range 160,170,180 bpm Low alarm range 90,100,110,120 bpm Scaling 20 bpm FHR chart width 7cm Toco Measurement range 0 to 100 units Chart width 4 cm Resolution 1 mmHg Recorder Type High resolution thermal printer Chart speed 1/2/3 cm/min Record paper Z fold ,Thermal Electrical Power supply 100-240 V AC 50Hz ± 10% Power consumption < 40 W Inbuilt battery Rechargeable 8.4 V Li-ion Battery operating time 2 hours (No printer working) Speaker 1 W Memory 10 hours Display Screen Color LCD with tilt adjustment Physical characteristics Weight < 2 kgs Dimensions 73 H X 295 W X 240 D (mm) Operating condition Temperature 400C Pressure 50 to 160 Kpa Humidity Upto 90% non condensing Storage & Transport condition Temperature 600C Pressure 50 to 160 Kpa Humidity Upto 90% non condensing Optional Facility Fetal Acoustic Stimulator

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 25: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 22

Warranty This warranty is not applicable to any defect, due to an accident, misuse, mishandling, neglect, improper installation, improper repair or improper modification by personnel other than recommended qualified Mediline personnel. This warranty also does not apply if the system has not been operated and maintained in accordance with the operating and maintenance manuals, instructions or bulletins issued in respect thereof by Mediline. This warranty is strictly limited to replacement or repair of the part, which is found to be defective in material or workmanship. Mediline reserves the right to make changes in the design and material of system without incurring any obligations to incorporate such changes in system already completed on the effective date of any such change or changes. This is the only warranty of this product and is expressly in lieu of all other warranties, express or implied by law or otherwise, including any implied warranties of merchantability and of fitness for a particular purpose. Without regard to the alleged defect, Mediline does not, under any circumstances, assume any responsibility of the loss of time, inconvenience or other consequential damages, including but not limited to, loss or damage to personal property, or loss of revenue. Mediline has neither assume nor authorized any other person (including any distributor authorized to sell its system) to assume for it any other liability in connection with the sale of system. All rights reserved. Reproductions of any part of this manual in any form whatsoever without the written permission from Mediline is forbidden. The contents of this manual are subject to change without notice. All efforts have been made to ensure the accuracy of the content of this manual. However if any error found, Mediline would appreciate being informed. For any further details or for returning the damaged items contact: Maestros Mediline Systems Limited EL 63, TTC Industrial Estate Electronic Zone Mahape, Navi Mumbai – 400 701 INDIA. Phone: 91-22-27611311, 27611286 Fax : 91-22-27622153 Email: [email protected] Website: www.medi-line.com

PDF created with pdfFactory Pro trial version www.software-partners.co.uk

Page 26: New Coddle Graph Single User Manual

Maestros Medline Systems Limited 23

Appendix

Accelerations: A visually apparent, abrupt increase (defined as onset of acceleration to peak in <30 seconds) in FHR above the baseline. The peak is 15 bpm above the baseline, and the acceleration lasts =15 seconds.

Antenatal period: Period before labour.

Baseline FHR: Approximate mean FHR rounded to increments of 5 bpm during a 10-minute segment. Bradycardia FHR < 110 bpm and Tachycardia FHR >160 bpm.

Decelerations: A visually-apparent, gradual decrease (defined as onset of deceleration to lowest point = 30 seconds) and return to baseline FHR associated with a uterine contraction.

Expected Due Date: The due date or estimated date of delivery (EDD) is the date when a baby's birth is expected. It is set by a doctor or midwife and is usually based on the first day of a woman's last menstrual period. An ultrasound "dating scan" may be used to give a more accurate estimate of the due date based on measurements of the baby's size.

Fetal distress: Compromise of the fetus during the antepartum period (before labor) or intrapartum period (birth process). The term "fetal distress" is commonly used to describe fetal hypoxia (low oxygen levels in the fetus). The concern with fetal hypoxia is it may result in fetal damage or death if not reversed or if the fetus is not promptly delivered.

Fetal Heart Rate (FHR): The normal heart rate for a full term infant is 110-160 beats per minute.

Fetal movement: Motion of a fetus within the uterus (usually detected by the 16th week of pregnancy).

Gestation period: The period during which an embryo develops (about 266 days in humans).

Intrapartum period: Period during labour.

Short Term Variability: The fetal heart rate per minute changes calculated from one beat of the heart to the next.

Transducer: Any device or component that converts an input signal of one form to an output signal of another form-for instance, a piezoelectric transducer converts pressure waves into electrical signals, or vice versa.

Uterine contraction: A rhythmic tightening in labor of the upper uterine musculature that contracts the size of the uterus and pushes the fetus toward the birth canal.

*******

PDF created with pdfFactory Pro trial version www.software-partners.co.uk