15
+ + lorem ipsum Company Profile & Information Pack S p e c i a l i s e d H V A C a n d R e f r i g e r a t i o n C o n t r a c t o r s 0 1 1 6 1 3 3 2 1 4 | i n f o @ m o y a . c o . z a | w w w . m o y a . c o . z a

New info- pack nobus exmoya.co.za/home/wp-content/uploads/2015/10/New_Info_Pack.pdfIDT Dan Molefe (012) 845 2000 Cyfer Holdings Maintenance of Oppenheimer Residence Nyazengu Natasha

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: New info- pack nobus exmoya.co.za/home/wp-content/uploads/2015/10/New_Info_Pack.pdfIDT Dan Molefe (012) 845 2000 Cyfer Holdings Maintenance of Oppenheimer Residence Nyazengu Natasha

+

+

lorem ipsum

Company Profile & Information Pack Special ised HVAC and Refrigerat ion Contractors 011 613 3214 | [email protected] | www.moya.co.za

Page 2: New info- pack nobus exmoya.co.za/home/wp-content/uploads/2015/10/New_Info_Pack.pdfIDT Dan Molefe (012) 845 2000 Cyfer Holdings Maintenance of Oppenheimer Residence Nyazengu Natasha

2

Contents Page 3 Why Moya Air Conditioning (Pty) Ltd? 4 - 7 Company Profile & Key Personnel 8 - 10 Project References 11 – 15 Case Study: Museum Africa

+

Page 3: New info- pack nobus exmoya.co.za/home/wp-content/uploads/2015/10/New_Info_Pack.pdfIDT Dan Molefe (012) 845 2000 Cyfer Holdings Maintenance of Oppenheimer Residence Nyazengu Natasha

3

Why Moya Air Conditioning (Pty) Ltd That is a question that you may ask, why use Moya Air Conditioning (Pty) Ltd? What makes them so special?

Moya Air Conditioning (Pty) Ltd, is a multi faceted Heating, Ventilation and Air Conditioning contractor and manufacturer, established in 1999, to offer professional service and quality workmanship to clients and end users. Our skill base is varied and we are able to accomplish tasks that require more than from any ordinary contractor.

From our experience in building clean rooms for high radiation areas at Nuclear Energy Corporation of South Africa, to our building upgrades at South African National Blood Services and new BSL 3 Laboratory for NHLS our experience is varied and able to be applied to various projects including offices, factories, clean rooms, shopping centres, museums, stadia and much more.

Our quality of work speaks for itself, and as registered members of the South Africa Refrigeration and Air Conditioning Contractors Association (SARACCA) and Construction Industry Development Board (CIDB), we have a proven track record.

You will find in this correspondence to you, a company profile for your perusal. You can also view our company online at www.moya.co.za.

Don’t just take our word for it. These clients and many more all agree

+

Page 4: New info- pack nobus exmoya.co.za/home/wp-content/uploads/2015/10/New_Info_Pack.pdfIDT Dan Molefe (012) 845 2000 Cyfer Holdings Maintenance of Oppenheimer Residence Nyazengu Natasha

4

Company Profile

+

Company Information

Trading Name: Moya Air Conditioning (Pty) Ltd

HDI Equity Ownership: 70%

BBBEE Rating: Level 3 EME

BEE Procurement recognition: 110%

CIDB Rating: 5 ME

Memberships: SARACCA

SEIFSA

Contact Information

Physical Address: Unit G1, Supreme Industrial Park, Steeledale, 2197

Postal Address: PO Box 990386, Kibler Park, 2053

Telephone number: 011 613 3214

Fax Number: 086 692 1229

Email: [email protected]

Website: www.moya.co.za

Page 5: New info- pack nobus exmoya.co.za/home/wp-content/uploads/2015/10/New_Info_Pack.pdfIDT Dan Molefe (012) 845 2000 Cyfer Holdings Maintenance of Oppenheimer Residence Nyazengu Natasha

5

Company Profile

+

Mission

Dedicated to provide a client and service orientated approach to all our business. We strive to provide the best products with the highest quality service and workmanship �

Vision

Achieve Benchmark status within the Air Conditioning Service industry, strive to become a multi- faceted and dynamic Air Conditioning Service organization contributing to overall society and encompassing all the social values within South Africa

Services Offered

With more than 120 years of combined experience in the HVAC industry we are able to offer the following services:

- Turnkey solutions for all types of assignments including civil and structural projects

- Design, supply and installation of all types of HVAC Systems, Laboratories, Clean Rooms, Cold Rooms, VRV Systems, Chilled Water systems, Cooling towers, Refrigeration systems for all applications such as offices, office buildings, shopping centres, factories, hospitals, universities, museums, stadia and much more. Our experience is varied and wide ranging.

- Maintenance of all HVAC systems, Laboratories, Clean Rooms, Cold Rooms, VRV Systems,

Chilled Water Systems, Cooling Towers, Refrigeration Systems. Including after sale services and Service Level Agreements, that is cost effective and efficient.

- Proposals and Tenders for both private and public sector, in a variety of project disciplines.

- Equipment procurement, commissioning and project management services

- “Green Building” project planning, implementation and monitoring.

Page 6: New info- pack nobus exmoya.co.za/home/wp-content/uploads/2015/10/New_Info_Pack.pdfIDT Dan Molefe (012) 845 2000 Cyfer Holdings Maintenance of Oppenheimer Residence Nyazengu Natasha

6

Company Profile continued..

+

Organogram

Director

Financial Manager

Tender & Office Administrator

Contracts / Projects Manager

Director

Technicians

Assistants

Site Supervisor

Assistants

Management Profile

NAME

S.B. KONYANE Q.A. DAVIS

Citizenship

South African South African

PDI Status

Yes No

% Ownership

70% 30%

% Voting

70% 30%

Page 7: New info- pack nobus exmoya.co.za/home/wp-content/uploads/2015/10/New_Info_Pack.pdfIDT Dan Molefe (012) 845 2000 Cyfer Holdings Maintenance of Oppenheimer Residence Nyazengu Natasha

7

Key Personnel

So lomon Konyane: Operations Di rector Personal Detai ls : Date of Birth: 1956/04/26 ID No: 5604265527089Languages: Sotho/English/ Afrikaans Years in company employ: 13 years Qualifications: Refrigeration and Air Conditioning Technician (Jeppe Training College) Experience: 30 years Industry experience in all aspects of air conditioning including installations of all types of equipment from split units, ducted systems, server room installations, office installations, laboratory installations. Quint in Davis: Admin Director Personal Detai ls : Date of Birth: 1980/04/25 ID No: 8004255216081Languages: English/ Afrikaans Years in company employ: 10 years Qualifications: B.Com (RAU) Experience: 10 years management experience. Financial control and administrative day to day running of the organisation.

+

Wayne Burisch: Contracts Manager Personal Detai ls : Date of Birth: 1957/08/11 ID No: 5708115734082Languages: English/ Afrikaans Years in company employ: 5 years

Qualifications: MPC III – Salisbury Polytechnic FSAIRAC – 2008 (Member for 28 years)

Experience: 35 years Industry experience including sales, manufacturing, sales, design, service contracts. 20 years experience in design, manufacture and installation of chillers and chilled water installation including Air Handling units Barrett Hughes: Si te Superv ior Personal Detai ls : Date of Birth: 1980/01/19 ID No: 8001195202080Languages: English/ Afrikaans Years in company employ: 13 years Qualifications: ACRICSA Safe Handling of Gases SEIFSA – Safety Representative QualificationLevel 1 First Aid Experience: 15 years Industry experience in all aspects of air conditioning including installations of all types of equipment from split units, ducted systems, server room installations, office installations, laboratory installations.

Page 8: New info- pack nobus exmoya.co.za/home/wp-content/uploads/2015/10/New_Info_Pack.pdfIDT Dan Molefe (012) 845 2000 Cyfer Holdings Maintenance of Oppenheimer Residence Nyazengu Natasha

8

Project References Project Description Client Contact

BSL 3 Laboratory: NICD - NHLS

Upgrade of old laboratory to a new BSL 3 facility for Avian Influenza

National Health Laboratory Services

LTS Consulting – Hannes v/d Walt(012) 665-5405 072 530 0881

Museum Africa - HVAC upgrade

Installation of 3 new chilled water cooling system for 4th Floor, including new Daikin chiller and re-furbishment of existing Trane chillers

City of Johannesburg

Sue Robertson (011) 375- 6071

SANBS – Building Upgrade

Upgrade of Bloodbank Building and new cleanroom installations

SANBS SSI -DCSE John Iles (012) 367-5800

ARC- OVI: Upgrade of Blood Vaccine Facility

Upgrade of Blood Vaccine Facility and installation of HVAC and extract systems

ARC-OVI Mike Combrink (012) 529 9111

+

Page 9: New info- pack nobus exmoya.co.za/home/wp-content/uploads/2015/10/New_Info_Pack.pdfIDT Dan Molefe (012) 845 2000 Cyfer Holdings Maintenance of Oppenheimer Residence Nyazengu Natasha

9

Project References +

Cleanroom Installation: Necsa Radio Chemistry

Installation of new cleanroom in Buildung P1600

NECSA Marius Prinsloo (012) 305 5396

Installation of air conditioning in relay rooms at 21 sites

Installation of air conditioning systems in relay rooms in 21 sites at Metrorail stations.

Metrorail/ Prasa Craig van Stoltenkamp (011) 773 5878

NTP- New Microbiology Cleanroom

Provision of new Microbiology cleanroom at NTP - Pelindaba. Including installation of new Trane chiller.

NTP- Pelindaba SSI - DCSE Adrian Kelfkens (012) 367- 5800

Transnet - Installation of extract fans at Diesel Depot

Supply and Install new Axial Flow Fan extraction units with aluminum impreller, cowling and non return weather flaps complete. We were also responsible for the supply and installation of distribution boards with controls and contactors.

Transnet Transnet Projects- Justin Labuschagne (011) 773 7632

Page 10: New info- pack nobus exmoya.co.za/home/wp-content/uploads/2015/10/New_Info_Pack.pdfIDT Dan Molefe (012) 845 2000 Cyfer Holdings Maintenance of Oppenheimer Residence Nyazengu Natasha

10

Project References +

MAINTENANCE CONTRACTS

61 Katherine St, Sandton (Maintenance Contract)

Maintain the HVAC system at 61 Katherine Street, including three Trane chillers

Alexander Forbes Peter Tippett (011) 669-3035

MSD (Pty) Ltd Maintenance of the Pharma and Dispensary plants

MSD Jonathan Tshehla - (011) 655 3000

Independent Development Trust

Maintenance of office building

IDT Dan Molefe (012) 845 2000

Cyfer Holdings Maintenance of Oppenheimer Residence

Nyazengu Natasha Tshehla 072 560 9442

Page 11: New info- pack nobus exmoya.co.za/home/wp-content/uploads/2015/10/New_Info_Pack.pdfIDT Dan Molefe (012) 845 2000 Cyfer Holdings Maintenance of Oppenheimer Residence Nyazengu Natasha

11

Case Study – Museum Africa Project: Upgrade of Air condit ioning at Museum Africa Cl ient: City of Johannesburg Consultant: M&C Consult ing Engineers

Page 12: New info- pack nobus exmoya.co.za/home/wp-content/uploads/2015/10/New_Info_Pack.pdfIDT Dan Molefe (012) 845 2000 Cyfer Holdings Maintenance of Oppenheimer Residence Nyazengu Natasha

12

Introduction:

Moya Air Conditioning (Pty) Ltd, won the right via tender in January 2009, to upgrade

the air conditioning in the West display and History store areas on the 3rd and 4th floor

at Museum Africa in Newtown, Johannesburg.

Project entailed the installation of a chiller and chilled water system, complete with

three custom built Air Handling Units and spiral ducting to the display areas.

The project was part of the upgrade of the Museum facilities, in anticipation of

increased visitor numbers during the World Cup 2010.

A breakdown of the project elements follows:

Page 13: New info- pack nobus exmoya.co.za/home/wp-content/uploads/2015/10/New_Info_Pack.pdfIDT Dan Molefe (012) 845 2000 Cyfer Holdings Maintenance of Oppenheimer Residence Nyazengu Natasha

13

Project elements A breakdown of the key components

Daik in Air Cooled Chil ler

Installation of a 400Kw Chiller, complete

with all necessary piping and steel

structure to keep the chiller above street

level.

Moya Air Conditioning (Pty) Ltd, handled

the design of the structure, the erection

of the structure including all necessary

civils work, the rigging of the chiller in

place and the certification of the

structure by a registered structural

engineer. All necessary OHS

requirements were handled and met.

Custom built AHU

Moya Air Conditioning (Pty) Ltd custom

manufactured three chilled water Air

Handling Units, to supply cooling and

humidity control to the areas.

It is critical that the Relative Humidity

remains constant at 40%, to maintain

the integrity of the artifacts on display

and in storage.

Use was made of a three way

modulating valves and automatic

package humidifiers to maintain

temperature and humidity to the areas.

13

Painted Spira l ducting

In order to accentuate the aesthetics of

the display area spiral galvanized

ducting painted white was used. We

installed more than 270m2 of spiral

ducting into the display area

Other components

Also supplied, were new distribution

boards, electrics and cabling to run the

chiller and AHU’s. Each AHU, is run

independently through its own Motor

Control Board, with future BMS

integration.

Page 14: New info- pack nobus exmoya.co.za/home/wp-content/uploads/2015/10/New_Info_Pack.pdfIDT Dan Molefe (012) 845 2000 Cyfer Holdings Maintenance of Oppenheimer Residence Nyazengu Natasha

14

Conclusion Successful project completed

This project was successfully completed on time and to the complete satisfaction of the client and consulting

engineers.

This project showed the versatility, diverse knowledge and capability of Moya Air Conditioning (Pty) Ltd and it’s

staff.

The installation continues to operate and maintain the critical conditions in the store area and pleasant conditions

for visitors in the display area.

Project contacts:

Client: City of Johannesburg – Sue Robertson – [email protected] - 011375 - 6071

Consulting Engineers: M&C Consulting Engineers – Val Fiorotto – [email protected] - 0114409953

Page 15: New info- pack nobus exmoya.co.za/home/wp-content/uploads/2015/10/New_Info_Pack.pdfIDT Dan Molefe (012) 845 2000 Cyfer Holdings Maintenance of Oppenheimer Residence Nyazengu Natasha

+

+

For your next project, please feel free to contact

us.

Details below:

Moya Air Conditioning (Pty) Ltd Unit G1, Supreme Industrial Park, Steeledale

(t) 011 613 3214 | (f) 086 692 1229 | (e) [email protected]