REV 2019 04 05 NEW PRODUCT REVIEW Products approved and not yet incorporated into current standards INDEX Storm water Products Porous Pavements o Pave Drain System……………………………………………………………………. Page A1 o Belgard Interlocking Concrete Paver System…………………………….. Page A7 Storm Water Detention/Storage Products o ACF Environmental R-Tank, R-Tank HD, R-Tank SD……………………………….......... Page B1 o Cultech Cultech Contractor and Recharger Chamber Systems……. Page B3 o Hancor Hancor StorMaster…………………………………………………………. Page B6 o Prinsco HydroStor HS75 and HS180……………………………………………. Page B8 o RainStor System RainStore System…………………………………………………………… Page B11 o Oldcastle Precast StormCapture SC1, SC2 Detention System……………………… Page B13 o Storm Tech Storm Tech MC3500………………………………………………………. Page B17 Storm Tech MC4500………………………………………………………. Page B18 o Storm Trap Storm Trap Concrete Modular Storm Water Detention System…………………………………………………………… Page B21 o ABT, Inc Permavoid 85 and 150 Systems………………………………………… Page B23 o Lane Enterprises StormKeeper System……………………………………………………… Page B25 Storm Water Conveyance Products o ADS ADS N-12HP and Sanitite Pipes 12” through 60”…………….. Page C1 ADS Nyloplast Drain Basins, Inline Drains and Ductile Iron Frames and Grates………………………………………………………….. Page C3 o Contech

NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

REV 2019 04 05

NEW PRODUCT REVIEW

Products approved and not yet incorporated into current standards

INDEX

Storm water Products

Porous Pavements

o Pave Drain System……………………………………………………………………. Page A1o Belgard Interlocking Concrete Paver System…………………………….. Page A7

Storm Water Detention/Storage Products

o ACF Environmental R-Tank, R-Tank HD, R-Tank SD……………………………….......... Page B1

o Cultech Cultech Contractor and Recharger Chamber Systems……. Page B3

o Hancor Hancor StorMaster…………………………………………………………. Page B6

o Prinsco HydroStor HS75 and HS180……………………………………………. Page B8

o RainStor System RainStore System…………………………………………………………… Page B11

o Oldcastle Precast StormCapture SC1, SC2 Detention System……………………… Page B13

o Storm Tech Storm Tech MC3500………………………………………………………. Page B17 Storm Tech MC4500………………………………………………………. Page B18

o Storm Trap Storm Trap Concrete Modular Storm Water

Detention System…………………………………………………………… Page B21o ABT, Inc

Permavoid 85 and 150 Systems………………………………………… Page B23o Lane Enterprises

StormKeeper System……………………………………………………… Page B25

Storm Water Conveyance Products

o ADS ADS N-12HP and Sanitite Pipes 12” through 60”…………….. Page C1 ADS Nyloplast Drain Basins, Inline Drains and Ductile Iron

Frames and Grates………………………………………………………….. Page C3o Contech

Page 2: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

REV 2019 04 05

A-2000 Storm Water Pipe……………………………………………….. Page C5o Hancor

60” HDPE Pipe…………………………………………………………………. Page C6o Harco Fabricated Drainage Products

Harco Drainage Basins, Inline Drains and Ductile Iron Frames and Grates………………………………………………………….. Page C8

o Prinsco Prinsco ECOFLO 100………………………………………………………… Page C11 Prinsco Gold Flo and Gold Flo WT……………………………………. Page C12

Misc. Storm Water Products

o Sekisui SPR Americas, LLC Sekisui SPR Spiral Wound Pipe………………………………………….. Page D1

Page 3: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page A 1

Page 4: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page A 2

Page 5: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page A 3

Page 6: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page A 4

Page 7: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page A 5

Page 8: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page A 6

Page 9: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page A 7

Page 10: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page A 8

Page 11: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page A 9

Page 12: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page A 10

Page 13: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page A 11

Page 14: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page A 12

Page 15: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

November 25, 2015

Christa Petzke, PE, MBA

Engineered Products Manager

D2 Land & Water Resource

2600 Bloyd Avenue

Indianapolis, Indiana 46218

RE: ACF environmental R-Tank Storm Water Systems

Dear Ms. Petzke:

The City of Indianapolis (the City) Department of Public Works (DPW) thanks you for the

information on the ACF environmental R-Tank Storm Water Systems submitted for review and

possible approval in the Indianapolis Stormwater District. The City’s consultant, DLZ Indiana

LLC (DLZ), has completed their review of the information and submitted their report to DPW

(attached). DPW subsequently reviewed DLZ’s report and has made the following

determination.

Based on this conclusion, the DPW is approving the application of the ACF environmental R-

Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the

district for use on private underground detention and will be considered by DPW project

managers in order to identify on a case by case basis where this product may be best suited,

provided the following criteria are met:

All underground detention facilities shall be designed with a positive gravity outfall or a

certification from a licensed geotechnical engineer confirming that:

• The permeability of the surrounding soils will dissipate water at a rate required

for the detention facility designed

• No adverse impact to any subsurface systems (including septic systems) will be

experienced

• The underground detention facility will not be subject to ground water surcharge

during any time of the year

Any facility that allows infiltration within a “Well-Head Protection Area” needs prior

approval from the Department of Public Works Office of Environmental Services.

Page B 1

Page 16: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

If the system is designed to use the storage volume of the stone surrounding the structure,

a 40 percent porosity factor shall be utilized for the surrounding washed #8 stone.

All storm water shall be routed through a Storm Water Best Management Practice (BMP)

meeting City Standards prior to the detention area.

No storm water shall be routed through the ACF environmental R-Tank storm water

detention facility until the BMP is installed and fully functional and all erosion control

measures for disturbed areas are installed to ensure that sediment build-up in the

underground detention storage facility is minimized. The erosion control methods and

BMP’s must be inspected after each rain event and repaired or cleaned when necessary.

The O&M Manual for all BMP’s located prior to the underground detention storage

facility requires the BMP’s to be inspected four times per year and cleaned as necessary

to ensure maximum performance relative to sediment removal.

Underground storage vaults shall be constructed of accepted storm sewer pipe materials

(Section 402), manufactured, tested, and installed according to those guidelines set forth

herein.

The sizing of the plastic chamber system should follow the City of Indianapolis’ Storm

Water Design and Construction Specifications Manual. The chamber storage system is

treated in similar fashion to a detention/retention pond as far as sizing, and therefore such

calculations should be made in the same manner. The actual number of chambers and

configuration of the chambers shall be based on engineer’s specifications and

calculations.

The City thanks you for your interest and looks forward to the application of the ACF

environmental R-Tank Storm Water Systems within the district.

If you have any questions regarding this matter, please contact me at 317-633-4120 or via email

at [email protected].

Sincerely,

Rachel Wilson, PE

Senior Project Manager

Attachment

cc: Stefan Wolfla, DCE

Allen Sparks, DPW

DPW and DPR, 1200 Madison, Suite 200

File: P:\Projects\New Products Committee\NPC 2011\New Products Files\S W\S W

Detention\R-Tank\Final Report and Letter to Vendor

Page B 2

Page 17: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page B 3

Page 18: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page B 4

Page 19: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page B 5

Page 20: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page B 6

Page 21: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page B 7

Page 22: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

August 31, 2015

Mr. Monty Storms

Prinsco, Inc.

15221 Laurel Ridge Place

Leo, Indiana 46765

RE: New Product Review\ HydroStor HS75 and HS180 Chamber Subsurface Stormwater

Strorage Chamber

Dear Mr. Storms:

You have requested formal review of your products “HydroStor HS75 and HS180 Chamber” for

underground storm water detention. The New Products Committee of the Department of Public

Works has recommended approval the HydroStor HS75 and HS180 Chamber. Therefore, these

products have been approved by for use on private development and public projects for

underground storm water detention, provided the following criteria are met:

High Impact Polypropylene or High-Density Polyethylene Plastic Facilities

The chambers’ plastic shall be resistant to environmental stress cracking and maintain

adequate stiffness through the higher temperatures experienced during installation and

service. The chambers shall be designed to exceed the American Association of State

Highway and Transportation Officials (AASHTO) recommended Load and Resistance

Factor Design (LRFD) for earth loads and HS-20 live loads, with consideration for

impact and multiple presences when installed per the manufacturer’s minimum

requirements. The plastic chambers shall have a design life of 75 years, Class 1 and Class

3 Storm Water System.

All underground detention facilities shall be designed with a positive gravity outfall or a

certification from a licensed geotechnical engineer that:

The permeability of the surrounding soils will dissipate water at a rate required

for the detention facility designed

No adverse impact to any subsurface systems (including septic systems) will be

experienced

Page B 8

Page 23: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

August 31, 2015

Mr. Monty Storms

Page 2

The underground detention facility will not be subject to ground water surcharge

during any time of the year

Any facility that allows infiltration within a “Well-Head Protection Area” needs prior

approval from the Department of Public Works Office of Environmental Services.

If the system is designed to use the storage volume of the stone surrounding the structure,

a 40 percent porosity factor shall be utilized for the surrounding washed #8 stone.

All storm water shall be routed through a Storm Water Best Management Practice (BMP)

meeting City Standards prior to the detention area.

No storm water shall be routed through the HydroStor HS75 or HS180 Chamber facility

until the BMP is installed and fully functional and all erosion control measures for

disturbed areas are installed to ensure that sediment build-up in the underground

detention storage facility is minimized. The erosion control methods and BMP’s must be

inspected after each rain event and repaired or cleaned when necessary. The O&M

Manual for all BMP’s located prior to the underground detention storage facility requires

the BMP’s to be inspected four times per year and cleaned as necessary to ensure

maximum performance relative to sediment removal.

Underground storage vaults shall be constructed of accepted storm sewer pipe materials

(Section 402), manufactured, tested, and installed according to those guidelines set forth

herein.

The sizing of the plastic chamber system should follow the City of Indianapolis’ Storm

Water Design and Construction Specifications Manual. The chamber storage system is

treated in similar fashion to a detention/retention pond as far as sizing, and therefore such

calculations should be made in the same manner. The actual number of chambers and

configuration of the chambers shall be based on engineer’s specifications and

calculations.

Page B 9

Page 24: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

August 31, 2015

Mr. Monty Storms

Page 3

A maintenance system shall be set up for the chamber storage system. At a minimum,

the system shall be inspected for sediment and debris every three to six months until an

understanding of the operation of the system is obtained. To facilitate cleaning and

inspection, adequate access ports shall be provided into the chamber system.

The HydroStor HS75 and HS180 Chambers have been approved for H20 loads, but may

have limits for heavier loading such as fire truck stations around buildings. Specific

considerations must be part of the engineering design for locations.

If you have any other questions on this issue, please feel free to contact Bill Bowman at

[email protected]. Bill is spearheading the New Products Committee and will be glad to

help you.

Sincerely,

Rachel Wilson, P.E.

Project Engineer

DPW Engineering, City of Indianapolis

New Products Committee Storm Water Chair

cc: Melody P.E., Deputy Director

Larry Jones, Deputy Director, DPW Engineering

New Products Committee

Department of Code Compliance

File: P:\Projects\New Products Committee\NPC 2011\New Products Files\S W\S W

Detention \Approval Letter_20150824(F).docx

Page B 10

Page 25: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page B 11

Page 26: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page B 12

Page 27: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

������������������

����������������� Page B 13

fstewart
Rectangle
fstewart
Rectangle
Page 28: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

������������������

����������������� Page B 14

fstewart
Rectangle
fstewart
Rectangle
Page 29: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

������������������

�����������������

Page B 15

fstewart
Rectangle
fstewart
Rectangle
Page 30: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page B 16

Page 31: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page B 17

Page 32: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page B 18

Page 33: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page B 19

Page 34: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page B 20

Page 35: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page B 21

Page 36: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page B 22

Page 37: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page B 23

Page 38: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page B 24

Page 39: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page B 25

Page 40: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page B 26

Page 41: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page B 27

Page 42: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page C 1

Page 43: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page C 2

Page 44: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page C 3

Page 45: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page C 4

Page 46: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page C 5

Page 47: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page C 6

Page 48: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page C 7

Page 49: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page C 8

Page 50: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page C 9

Page 51: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page C 10

Page 52: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page C 11

Page 53: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page C 12

fstewart
Rectangle
Page 54: NEW PRODUCT REVIEW Products approved and not …...Tank Storm Water Systems Units R-Tank, R-Tank HD, and R-Tank SD for use within the district for use on private underground detention

Page D 1