2
VAPORIZER THERMACAST TM ELECTRIC Replaceable stainless steel cartridge heaters NEMA 4 Electrical Cabinet Adjustable outlet temperature from 40°F to 120°F Fully automaƟc operaƟon Compact design Redundant high temperature switches for safety Stainless steel casƟng jacket with insulaƟon for corrosion resistance, low maintenance, improved appearance, and safety Thermacast™ unit comes fully factory wired, tested and ready to install Quick delivery of standard units Built in conformance with ASME B31.3 Process Piping Code 300 series Stainless Steel/Brass weƩed parts Design pressure of 1,000 PSIG (Combo opƟon reduces MAWP to 500 PSIG) Terminals to allow for emergency shutdown Dry contacts for main contractor ON and high block temperature limit Auxiliary 120V terminals (2 A max.) The components and electrical cabinet are all UL/cUL marked, and the heaƟng elements are all UL recog- nized and CSA cerƟed. All-Canada CRN Standard features Low Temperature Cut O(LTCO) Kit featuring a temperature sensor and solenoid valve to prevent the ow of cold gas or liquid downstream of the vaporizer, 500 PSIG MAWP (add on item to any unit) Combo units with addiƟonal vaporizaƟon circuit for pressure building. Thermacast™ vaporizers in 15, 30 and 50 kW raƟngs have main coils for process vaporizaƟon and smaller secondary coils for pressure building. The pressure building coil comes with a pressure switch and solenoid valve to maintain the pressure in a CO 2 tank. Pressure switch is adjustable from 100 to 375 PSIG “All-Weather” Package including NEMA 4X main high-voltage cabinet and side 120V cabinet, and internal cabinet heater JuncƟon box with remote cabinet for hazardous area installaƟon Standard Options Product Datasheet 1.0 Simpli ed Flow Diagram Simpli ed Flow Diagram Cryogenic Tank Thermacast™ Vaporizer Gas to Use Point Temperature set point is adjustable OpƟonal LTCO Thermacast™ units for Argon, Helium, Carbon Monoxide, Ethanol, Ammonia, Chlorine, Ethylene, Methanol, SO 2 , N 2 O, etc. Gas outlet temperature from -40°F to 400°F Design pressure to 12,000 PSIG High Purity, electropolished units Monel, Hastelloy or 316 Stainless Steel weƩed part construcƟon materials Class 1, Division 2, Group B, C, or D Hazardous Area Purge Package Remote Cabinet OpƟon Custom Inlet/Outlet ConnecƟons or Flanges Custom controls and contacts Custom Options

New TM VAPORIZER - Chart Industries, Inc.files.chartindustries.com/PDS1.0.pdf · 2020. 3. 26. · Thermacast™ Vaporizer Gas to Use Point Temperature set point is adjustable Op onal

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: New TM VAPORIZER - Chart Industries, Inc.files.chartindustries.com/PDS1.0.pdf · 2020. 3. 26. · Thermacast™ Vaporizer Gas to Use Point Temperature set point is adjustable Op onal

VAPORIZERTHERMACASTTM ELECTRIC

Replaceable stainless steel cartridge heatersNEMA 4 Electrical CabinetAdjustable outlet temperature from 40°F to 120°FFully automa c opera onCompact designRedundant high temperature switches for safetyStainless steel cas ng jacket with insula on for corrosion resistance, low maintenance, improved appearance, and safetyThermacast™ unit comes fully factory wired, tested and ready to installQuick delivery of standard unitsBuilt in conformance with ASME B31.3 Process Piping Code300 series Stainless Steel/Brass we ed partsDesign pressure of 1,000 PSIG (Combo op on reduces MAWP to 500 PSIG)Terminals to allow for emergency shutdownDry contacts for main contractor ON and high blocktemperature limitAuxiliary 120V terminals (2 A max.) The components and electrical cabinet are all UL/cUL marked, and the hea ng elements are all UL recog-nized and CSA cer fied. All-Canada CRN

Standard features

Low Temperature Cut Off (LTCO) Kit featuring a temperature sensor and solenoid valve to prevent the flow of cold gas or liquid downstream of the vaporizer, 500 PSIG MAWP (add on item to any unit)Combo units with addi onal vaporiza on circuit for pressure building. Thermacast™ vaporizers in 15, 30 and 50 kW ra ngs have main coils for process vaporiza on and smaller secondary coils for pressure building. The pressure building coil comes with a pressure switch and solenoid valve to maintain the pressure in a CO2 tank. Pressure switch is adjustable from 100 to 375 PSIG“All-Weather” Package including NEMA 4X main high-voltage cabinet and side 120V cabinet, and internal cabinet heaterJunc on box with remote cabinet for hazardous area installa on

Standard Options

Product Datasheet 1.0

•••••

••

Simplified Flow DiagramSimplified Flow Diagram

Cryogenic Tank

Thermacast™ Vaporizer

Gas to Use Point Temperature set point is adjustable

Op onal LTCO

Thermacast™ units for Argon, Helium, Carbon Monoxide, Ethanol, Ammonia, Chlorine, Ethylene, Methanol, SO2, N2O, etc.Gas outlet temperature from -40°F to 400°FDesign pressure to 12,000 PSIGHigh Purity, electropolished unitsMonel, Hastelloy or 316 Stainless Steel we ed part construc on materialsClass 1, Division 2, Group B, C, or D Hazardous Area Purge PackageRemote Cabinet Op onCustom Inlet/Outlet Connec ons or FlangesCustom controls and contacts

Custom Options•

••

Page 2: New TM VAPORIZER - Chart Industries, Inc.files.chartindustries.com/PDS1.0.pdf · 2020. 3. 26. · Thermacast™ Vaporizer Gas to Use Point Temperature set point is adjustable Op onal

© 2019 Chart Inc. P/N 20979877

+1 508 999 1231

[email protected]

www.thermaxinc.com540 Hawthorn St. · Dartmouth, MA 02747 USA

Note: If the actual voltage differs from the design voltage of the vaporizer, the power and capacity will be effected by the ra o of (Vactual ÷ Vdesign)2.All tables shown in this Datasheet are intended as a guide that reflect our experience on these models. Actual performance may vary. Please call Thermax Inc. for guidance on specific applica ons.

* Includes pressure switch and solenoid valve on outlet of PB circuit* 500 PSIG MAWP* Nominal power and capacity based on standard heater tolerances: +5/-10%* For 150 PSIG CO₂, the capacity will be de-rated by an additional 10%* For larger CO₂ applications, Thermax recommends a Thermacast™ for process and an Electric Side Arm (L224) for pressure building

* TV3 and TV7 are single phase units* Nominal power and capacity based on standard heater tolerances: +5/-10%* For 150 PSIG CO₂, the capacity will be de-rated by an additional 10%

NEMA 4 Electrical Control Cabinet

High Temperature Insulated Leads

High Temperature Switches for Safety

Replaceable Cartridge Heaters

Temperature Controller

Pipe Connection:

Inlet

Outlet

Thermax Vortex Coil Flow Vaporizer

Stainless Steel Jacket with Insulation

TV3 and TV7 are single phase wall mount units:

Standard Dimensions: 24” high x 20” wide x 12” deep

VAPORIZERTHERMACASTTM ELECTRIC