26
News from CAMAG Rolf Rolli CEO CAMAG

News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

News from CAMAG

Rolf RolliCEO CAMAG

Page 2: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

Agenda

50 Years CAMAGTLC VISUALIZER – a new powerful evaluation, visualization and archiving system for TLC platesTLC-MS Interface New Area Sales Manager responsible for France

Page 3: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

1958 - 2008

Page 4: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

• CAMAG has influenced Instrumental TLC since its inception

• All the customers around the globe we have made the built up of CAMAG to its current position possible

• We thank to you as our loyal customers

1958 - 2008

Page 5: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

More on our history to be found in the recent edition of CBS

Page 6: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

1958 – 2008 Instrumentation Development

CAMAG Chromacharger1965

CAMAG TLC Visualizer2008

Page 7: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

TLC Visualizer launchd Q3 2008

A new powerful evaluation, visualization and archiving system for TLC plates

Page 8: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

Automatically finding the brightest spot (UV 366 mn)

Automatic Optimization

Page 9: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

Automatic Optimization

Camera adjusts for optimal illumination of the brightest spot

Page 10: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

Manual Optimization

If desired, a region of interest can be defined, in which the brightest spot is automatically found.

Page 11: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

Manual Optimization

Camera adjusts for optimal illumination of the brightest spot in the region of interest

Page 12: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

RF-Tool to measure RF of the substancesRF-Tool to measure RF of the substances

winCATS with TLC Visualizer

Page 13: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

Plate subtraction

Empty plate before application

Plate after development

Plate after clean plate subtraction

Page 14: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

TLC Visualizer / Image Comparison

Tracks 19, 15, 3 (on the left)are used for reference

Image comparison viewer(single and multi plate)

Page 15: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

TLC-MS

Page 16: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

Customer Survey TLC-MSDo you have samples which you can’t analyze with LC-MS

Are you interested in a TLC-MS solution?

Page 17: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

TLC-MS Coupling/TLC-MS Interface

After this clear interest of the market CAMAG started TLC-MS coupling project• Easy and fast MS-analysis of TLC zones• Proved extractor principle of Dr. Luftmann (D)

Semi automatic instrument involving:• Automatic plunger movement & force control• Automatic cleaning• Precise positioning

Page 18: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

TLC-MS

Page 19: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

TLC-MS

Page 20: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

TLC-MS

Valve for connectionto MS on/off

Cleaning

Head up and down

Laser pointer on-off

Page 21: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

TLC-MS Coupling/TLC-MS Interface

TLC-MS Interface is currently being tested at collaborating universitiesTLC-MS Interface should be available for customers Q1 2009

Page 22: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

New Area Sales Manager responsible for France

Raphael Vizzini

Page 23: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

Back up Slides

Page 24: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

Principle of TLC/MS Coupling

HPTLC/ESI-MS

Page 25: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

Principle of TLC/MS Coupling

Valve controlStandby position

solvent bypasses extractor

Extraction position

solvent passes extractor

Page 26: News from CAMAG · 1958 – 2008 Instrumentation Development CAMAG Chromacharger 1965 CAMAG TLC Visualizer 2008. ... • Proved extractor principle of Dr. Luftmann (D) ... Principle

TLC-MS Coupling Interface

Head Movement