3
1 3 7 NGL 1 1 NGL 4 NGL 4 1 4 4 4 2 2 8 NGL NGL NGL NGL 1 3 7 NGL NGL NGL 1 1 4 4 1 4 4 4 2 2 8 SCALE 1:100 NORTH ELEVATION 2 SCALE 1:100 EAST ELEVATION 3 SCALE 1:100 SECTION A-A 1 SCALE 1:100 SOUTH ELEVATION 4 SCALE 1:100 WEST ELEVATION 5 67 7th street linden johannesburg tel: 011 782 1860 DRAWING TITLE PROJECT B T3 1604 SECTION A-A & ELEVATIONS DUPLEX TYPE A - 3 BED/ 2 BATH BRYANSTON EXT.7 on ERVEN 3495,3496,3497 NEW TOWNHOUSES

NGL NGL - tnd.co.za · INSULATION NOTE: 135mm thick thermal and acoustic insulation . SLAB EDGE NOTE: concrete slab edge for plaster and paint finish as per spec. 85mm step. ROOF

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: NGL NGL - tnd.co.za · INSULATION NOTE: 135mm thick thermal and acoustic insulation . SLAB EDGE NOTE: concrete slab edge for plaster and paint finish as per spec. 85mm step. ROOF

1

3

7

NGL

1

1

NGL

4

NGL

41444

228

NGL

NGL NGL

NGL

1

3

7

NGL

NGLNGL

1

14

4 1 4 4 4

2 28

SCALE 1:100NORTH ELEVATION2 SCALE 1:100

EAST ELEVATION3

SCALE 1:100SECTION A-A1

SCALE 1:100SOUTH ELEVATION4 SCALE 1:100

WEST ELEVATION5

67 7th street linden johannesburgtel: 011 782 1860

DRA

WIN

G T

ITLE

PR

OJE

CT

BT31604

SECTION A-A & ELEVATIONSDUPLEX TYPE A - 3 BED/ 2 BATH

BRYANSTON EXT.7on ERVEN 3495,3496,3497

NEW TOWNHOUSES

AutoCAD SHX Text
0,000 t/o surface bed (GROUND)
AutoCAD SHX Text
2,890 t/o slab (FIRST)
AutoCAD SHX Text
2,125 u/s lintol
AutoCAD SHX Text
5,015 u/s lintol
AutoCAD SHX Text
5,525 u/s wallplate
AutoCAD SHX Text
0,000 t/o surface bed (GROUND)
AutoCAD SHX Text
2,890 t/o slab (FIRST)
AutoCAD SHX Text
2,125 u/s lintol
AutoCAD SHX Text
5,015 u/s lintol
AutoCAD SHX Text
5,525 u/s wallplate
AutoCAD SHX Text
lintol
AutoCAD SHX Text
0,000 t/o surface bed (GROUND)
AutoCAD SHX Text
2,890 t/o slab (FIRST)
AutoCAD SHX Text
2,125 u/s lintol
AutoCAD SHX Text
5,015 u/s lintol
AutoCAD SHX Text
5,525 u/s wallplate
AutoCAD SHX Text
0,000 t/o surface bed (GROUND)
AutoCAD SHX Text
2,890 t/o slab (FIRST)
AutoCAD SHX Text
2,125 u/s lintol
AutoCAD SHX Text
5,015 u/s lintol
AutoCAD SHX Text
5,525 u/s wallplate
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
lintol
AutoCAD SHX Text
lintol
AutoCAD SHX Text
DOUBLE GARAGE
AutoCAD SHX Text
(grano)
AutoCAD SHX Text
SCULLERY
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
DINING ROOM
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
COVERED PATIO
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
lintol
AutoCAD SHX Text
BATHRM 2
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
BATHRM 1
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
DRESSER
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
BEDROOM 1
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
lintol
AutoCAD SHX Text
lintol
AutoCAD SHX Text
lintol
AutoCAD SHX Text
0,000 t/o surface bed (GROUND)
AutoCAD SHX Text
2,890 t/o slab (FIRST)
AutoCAD SHX Text
2,125 u/s lintol
AutoCAD SHX Text
5,015 u/s lintol
AutoCAD SHX Text
5,525 u/s wallplate
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
0,000 t/o surface bed (GROUND)
AutoCAD SHX Text
2,890 t/o slab (FIRST)
AutoCAD SHX Text
2,125 u/s lintol
AutoCAD SHX Text
5,015 u/s lintol
AutoCAD SHX Text
5,525 u/s wallplate
AutoCAD SHX Text
0,000 t/o surface bed (GROUND)
AutoCAD SHX Text
2,890 t/o slab (FIRST)
AutoCAD SHX Text
2,125 u/s lintol
AutoCAD SHX Text
5,015 u/s lintol
AutoCAD SHX Text
5,525 u/s wallplate
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
0,000 t/o surface bed (GROUND)
AutoCAD SHX Text
2,890 t/o slab (FIRST)
AutoCAD SHX Text
2,125 u/s lintol
AutoCAD SHX Text
5,015 u/s lintol
AutoCAD SHX Text
5,525 u/s wallplate
AutoCAD SHX Text
JETMASTER braai or similar approved
AutoCAD SHX Text
ROOF NOTE 1: concrete roof tiles or similar approved at 25° pitch onapproved underlay on 38 x 38mm SAP timber battens on SAP timber roof truss on 114 x 38mm wallplate, all to specification
AutoCAD SHX Text
CEILING NOTE: 6,4mm gypsum plasterboard with 75mm cornice fixed to 38x38 SAP brandering
AutoCAD SHX Text
CORBEL NOTE: brick corbel to top of parapet wall with 50mm projections to detail, for plaster and paint finish
AutoCAD SHX Text
GUTTER & RWDP NOTE: "OGEE" profile chromadek gutter and rain water down pipe
AutoCAD SHX Text
LINTOL NOTE: face brick on edge lintol over windows/doors
AutoCAD SHX Text
FACEBRICK NOTE: "Country Classic Travertine" or similar approved facebrick panel
AutoCAD SHX Text
foundation to engineers detail
AutoCAD SHX Text
foundation to engineers detail
AutoCAD SHX Text
foundation to engineers detail
AutoCAD SHX Text
foundation to engineers detail
AutoCAD SHX Text
LINTOL NOTE: face brick on edge lintol over windows/doors
AutoCAD SHX Text
BALUSTRADE NOTE: purpose made steel balustrade to later detail max 100c/c openings
AutoCAD SHX Text
INSULATION NOTE: 135mm thick thermal and acoustic insulation
AutoCAD SHX Text
SLAB EDGE NOTE: concrete slab edge for plaster and paint finish as per spec.
AutoCAD SHX Text
85mm step
AutoCAD SHX Text
ROOF NOTE 1: RE: SIM NOTE 1/T3
AutoCAD SHX Text
FACEBRICK NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
CORBEL NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
BALUSTRADE NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
WALL TILE NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
ramp
AutoCAD SHX Text
LINTOL NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
CILL NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
WINDOW NOTE: RE: WINDOW SCHEDULE
AutoCAD SHX Text
GUTTER & RWDP NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
DUCT NOTE:
AutoCAD SHX Text
350mm x 230mm
AutoCAD SHX Text
drainage duct with fibre
AutoCAD SHX Text
cement duct cover
AutoCAD SHX Text
WALL TILE NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
GUTTER & RWDP NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
CORBEL NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
ROOF NOTE 1: RE: SIM NOTE 1/T3
AutoCAD SHX Text
LINTOL NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
WINDOW NOTE: RE: WINDOW SCHEDULE
AutoCAD SHX Text
DOOR NOTE: RE: DOOR SCHEDULE
AutoCAD SHX Text
ARCH NOTE: arch over with recess below and plaster "Keystone" above
AutoCAD SHX Text
WALL TILE NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
BALUSTRADE NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
ARCH NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
ROOF NOTE 1: RE: SIM NOTE 1/T3
AutoCAD SHX Text
CORBEL NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
GUTTER & RWDP NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
LINTOL NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
CHIMNEY NOTE :Old world concrete model for 330h x 267 (diameter) chimney pot or similar approved
AutoCAD SHX Text
CHIMNEY NOTE : RE: SIM NOTE 1/T3
AutoCAD SHX Text
CHIMNEY NOTE : RE: SIM NOTE 1/T3
AutoCAD SHX Text
0,000 t/o surface bed (GROUND)
AutoCAD SHX Text
2,890 t/o slab (FIRST)
AutoCAD SHX Text
2,125 u/s lintol
AutoCAD SHX Text
5,015 u/s lintol
AutoCAD SHX Text
5,525 u/s wallplate
AutoCAD SHX Text
0,000 t/o surface bed (GROUND)
AutoCAD SHX Text
2,890 t/o slab (FIRST)
AutoCAD SHX Text
2,125 u/s lintol
AutoCAD SHX Text
5,015 u/s lintol
AutoCAD SHX Text
5,525 u/s wallplate
AutoCAD SHX Text
ROOF NOTE 1: RE: SIM NOTE 1/T3
AutoCAD SHX Text
FACEBRICK NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
CORBEL NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
BALUSTRADE NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
WALL TILE NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
LINTOL NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
CILL NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
WINDOW NOTE: RE: WINDOW SCHEDULE
AutoCAD SHX Text
GUTTER & RWDP NOTE: RE: SIM NOTE 1/T3
AutoCAD SHX Text
DUCT NOTE:
AutoCAD SHX Text
350mm x 230mm
AutoCAD SHX Text
drainage duct with fibre
AutoCAD SHX Text
cement duct cover
AutoCAD SHX Text
CHIMNEY NOTE : RE: SIM NOTE 1/T3
AutoCAD SHX Text
FLOOR NOTES: Floor finish on screed on 85mm concrete surface be on layers well compacted fill.
AutoCAD SHX Text
RECESS NOTE: 115mm recess in brickwork
AutoCAD SHX Text
RECESS NOTE: RE SIM NOTE 2/T3
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
CEILING NOTE: garage to have 12,7mm fire rated ceiling
AutoCAD SHX Text
2016-04-13
AutoCAD SHX Text
issued for PRELIMINARY
AutoCAD SHX Text
TM
AutoCAD SHX Text
A
AutoCAD SHX Text
re-issued for INFORMATION
AutoCAD SHX Text
2016-04-19
AutoCAD SHX Text
general revisions made as per client/interior meeting
AutoCAD SHX Text
RA
AutoCAD SHX Text
B
AutoCAD SHX Text
CONSULTANT/REFERENCE DRAWING INDEX
AutoCAD SHX Text
REV
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
DRAWING No.
AutoCAD SHX Text
DISCIPLINE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
NOTE: contractor to check all dimensions on site and on drawings, any discrepancies must be reported to the architect. only figured dimensions are to be taken. This drawing is the property of E2 Architects + Urban Designers. copyright is reserved by them and the drawing is issued on the condition that it is not amended, copied, reproduced, retained or disclosed to any unauthorised person, either wholly or in part without the written consent of E2 Architects + Urban Designers. All work to comply with NATIONAL BUILDING REGULATIONS ACT 103 OF 1977 and the latest edition of the SANS 10400 and any amendments thereto as well as the by-laws of the relevant local municipality These drawings are to be read in conjunction with structural engineer's, civil engineer's, or plumbing consultant's drawings where specified ROOFS:(in accordance with PART L of SANS 10400) (in accordance with PART L of SANS 10400) refer to sections and structural engineer's drawings where specified all roof fixings to be in accordance with PART K of SANS 10400 WALLS:(in accordance with PART K of SANS 10400) (in accordance with PART K of SANS 10400) refer to sections, provide brickforce every fifth course CEILINGS & CILLS: refer to sections D.P.C's: SABS approved throughout D.P.M's: (in accordance with PART J of SANS 10400) SABS approved throughout STRUCTURAL WORK: refer to structural engineer's details and specifications GLAZING: (in accordance with PART N of SANS 10400) SANS 10137 and 1263-1 1263-1 DRAINAGE: (in accordance with PART P of SANS 10400) SABS materials used throughout. 75mm deep seal traps used with with all waste fittings. all i.e's to be marked at the surface and sealed. WC's to have and sealed. WC's to have "S" or "P" traps with side access cleaning eyes. all WHB"s to have 32 diam. cleaning eyes. all WHB"s to have 32 diam. waste pipes and 40 dia. waste pipes to all other fittings dia. waste pipes to all other fittings GENERAL NOTES: all habitable rooms to have a minimum of 10% natural light and 5% natural ventilation to comply with the NATIONAL BUILDING REGULATIONS (SANS 10400) unless otherwise specified, refer to mechanical engineer's specification. all openings to have prestressed lintols over. brickforce to every course for 5 courses above lintol, brickforce to every fifth course of brickwork use figured dimensions only, do not scale off drawing
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
JOB No.
AutoCAD SHX Text
DRAWING No.
AutoCAD SHX Text
REV.
AutoCAD SHX Text
PAGE SIZE
AutoCAD SHX Text
A1
AutoCAD SHX Text
1:100
AutoCAD SHX Text
cbe
AutoCAD SHX Text
2016-03-30
Page 2: NGL NGL - tnd.co.za · INSULATION NOTE: 135mm thick thermal and acoustic insulation . SLAB EDGE NOTE: concrete slab edge for plaster and paint finish as per spec. 85mm step. ROOF

1a

2

3

2

3

4

1

1

2

2

3

3

4

1a

2

3

2

3

4

1

1

2

2

3

3

4

2

2

55

6

2

1

1

4

4

2

3

2

1a

6

2

1

1

4

4

2

3

2

1a

6

2

3

6

41

2

8

1a

2

3

4

6 6

1

6 6

1a

1

3

2

4

2

3

6

1

2 2

SCALE 1:100FLOOR PLAN1

UNIT TYPE A

SCALE 1:100LOWER LEVEL PLAN2 SCALE 1:1003 UPPER LEVEL PLAN

UNIT TYPE A-LOFT

SCALE 1:100FLOOR PLAN4

UNIT TYPE B

UNIT TYPE B-LOFT

SCALE 1:100LOWER LEVEL PLAN5

UNIT TYPE C

SCALE 1:100UPPER LEVEL PLAN6 SCALE 1:100

FLOOR PLAN7

UNIT TYPE C-LOFT

67 7th street linden johannesburgtel: 011 782 1860

DRA

WIN

G T

ITLE

PR

OJE

CT

CT61604

and ELECTRICAL LAYOUTSUNIT PLANS

APARTMENTS

BRYANSTON EXT.7on ERVEN 3495,3496,3497

NEW TOWNHOUSES

AutoCAD SHX Text
TERRACE
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
85mm step
AutoCAD SHX Text
100mm soilpipe & ovp
AutoCAD SHX Text
DUCT NOTE: 350mm x 230mm drainage duct with fibre cement duct cover
AutoCAD SHX Text
COLUMN NOTE: 345mm x 345mm brick column enclosing rwdp to eng. detail
AutoCAD SHX Text
lintol above
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
LOUNGE
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
BEDROOM 1
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
BEDROOM 2
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
BTHRM.22
AutoCAD SHX Text
BTHRM.11
AutoCAD SHX Text
shr
AutoCAD SHX Text
shr
AutoCAD SHX Text
wc
AutoCAD SHX Text
van
AutoCAD SHX Text
bath
AutoCAD SHX Text
wc
AutoCAD SHX Text
wm
AutoCAD SHX Text
van
AutoCAD SHX Text
fr
AutoCAD SHX Text
dw
AutoCAD SHX Text
st
AutoCAD SHX Text
sink
AutoCAD SHX Text
bic
AutoCAD SHX Text
bic
AutoCAD SHX Text
lintol above
AutoCAD SHX Text
FIRE WALL TO U/S SLAB
AutoCAD SHX Text
85mm step
AutoCAD SHX Text
WALKWAY
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
DINING ROOM
AutoCAD SHX Text
linen
AutoCAD SHX Text
lintol above
AutoCAD SHX Text
for balustrade positions REFER: BLOCK PLANS
AutoCAD SHX Text
2 BED / 2 BATH
AutoCAD SHX Text
TOTAL:
AutoCAD SHX Text
UNIT:
AutoCAD SHX Text
85,88m2
AutoCAD SHX Text
AREA
AutoCAD SHX Text
COV. PATIO:
AutoCAD SHX Text
10,23m2
AutoCAD SHX Text
75,65m2
AutoCAD SHX Text
100mm soilpipe & ovp
AutoCAD SHX Text
DUCT NOTE: RE: SIM NOTE 1/T6
AutoCAD SHX Text
100mm soilpipe & ovp
AutoCAD SHX Text
DUCT NOTE: RE: SIM NOTE 1/T6
AutoCAD SHX Text
500mm extension on ground floor only
AutoCAD SHX Text
td
AutoCAD SHX Text
m
AutoCAD SHX Text
f
AutoCAD SHX Text
ex
AutoCAD SHX Text
st
AutoCAD SHX Text
refer kitchen layout for exact location of appliances
AutoCAD SHX Text
TOTAL:
AutoCAD SHX Text
UNIT:
AutoCAD SHX Text
AREA
AutoCAD SHX Text
COV. PATIO:
AutoCAD SHX Text
LOFT:
AutoCAD SHX Text
18,12m2
AutoCAD SHX Text
TOTAL:
AutoCAD SHX Text
122,47m2
AutoCAD SHX Text
TERRACE:
AutoCAD SHX Text
20,66m2
AutoCAD SHX Text
83,69m2
AutoCAD SHX Text
8,04m2
AutoCAD SHX Text
75,65m2
AutoCAD SHX Text
TERRACE
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
85mm step
AutoCAD SHX Text
100mm soilpipe & ovp
AutoCAD SHX Text
DUCT NOTE: RE: SIM NOTE 1/T6
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
BEDROOM 1
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
BEDROOM 2
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
BTHRM.22
AutoCAD SHX Text
BTHRM.11
AutoCAD SHX Text
shr
AutoCAD SHX Text
shr
AutoCAD SHX Text
wc
AutoCAD SHX Text
van
AutoCAD SHX Text
bath
AutoCAD SHX Text
wc
AutoCAD SHX Text
wm
AutoCAD SHX Text
van
AutoCAD SHX Text
fr
AutoCAD SHX Text
dw
AutoCAD SHX Text
st
AutoCAD SHX Text
sink
AutoCAD SHX Text
bic
AutoCAD SHX Text
lintol above
AutoCAD SHX Text
FIRE WALL TO U/S SLAB
AutoCAD SHX Text
85mm step
AutoCAD SHX Text
WALKWAY
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
DINING ROOM
AutoCAD SHX Text
linen
AutoCAD SHX Text
up
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
STAIRCASE NOTE: staircase with timber stringers, timber treads and mild steel balustrade to detail
AutoCAD SHX Text
PERGOLA NOTE: 120 x 60mm hollow steel sections on 120 x 120mm steel post to detail
AutoCAD SHX Text
BALUSTRADE NOTE: 1m high purpose made steel handrail to later detail max 100c/c openings
AutoCAD SHX Text
100mm soilpipe & ovp
AutoCAD SHX Text
DUCT NOTE: RE: SIM NOTE 1/T6
AutoCAD SHX Text
100mm soilpipe & ovp
AutoCAD SHX Text
DUCT NOTE: RE: SIM NOTE 1/T6
AutoCAD SHX Text
fall
AutoCAD SHX Text
LOUNGE
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
double volume
AutoCAD SHX Text
fall
AutoCAD SHX Text
fall
AutoCAD SHX Text
fall
AutoCAD SHX Text
85mm step
AutoCAD SHX Text
100mm soil pipe & ovp
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
HOPPER NOTE: outlet to powder-coated, purpose made hopper to rainwater downpipe
AutoCAD SHX Text
ROOF NOTE 1: concrete roof tiles or similar approved at 25° pitch onapproved underlay on 38 x 38mm SAP timber battens on SAP timber roof truss on 114 x 38mm wallplate, all to specification
AutoCAD SHX Text
PERGOLA NOTE: RE: SIM NOTE 2/T6
AutoCAD SHX Text
FIRE WALL TO U/S SLAB
AutoCAD SHX Text
STAIRCASE NOTE: RE: SIM NOTE 2/T6
AutoCAD SHX Text
CORBEL NOTE: brick corbel to top of parapet wall with 50mm projections to detail, for plaster and paint finish
AutoCAD SHX Text
HOPPER NOTE: RE: SIM NOTE 3/T6
AutoCAD SHX Text
ROOF NOTE 1: RE: SIM NOTE 3/T6
AutoCAD SHX Text
CORBEL NOTE: RE: SIM NOTE 3/T6
AutoCAD SHX Text
DUCT NOTE: RE: SIM NOTE 1/T6
AutoCAD SHX Text
BALUSTRADE NOTE: RE: SIM NOTE 1/T6
AutoCAD SHX Text
up
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
stormwater overflow pipe
AutoCAD SHX Text
2 BED / 2 BATH
AutoCAD SHX Text
bic
AutoCAD SHX Text
lintol above
AutoCAD SHX Text
LOUNGE
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
td
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
COVERED TERRACE
AutoCAD SHX Text
m
AutoCAD SHX Text
f
AutoCAD SHX Text
ex
AutoCAD SHX Text
st
AutoCAD SHX Text
ext
AutoCAD SHX Text
2
AutoCAD SHX Text
refer kitchen layout for exact location of appliances
AutoCAD SHX Text
TERRACE
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
bic
AutoCAD SHX Text
bic
AutoCAD SHX Text
bath
AutoCAD SHX Text
wc
AutoCAD SHX Text
van
AutoCAD SHX Text
shr
AutoCAD SHX Text
st
AutoCAD SHX Text
fr
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
BEDROOM 1
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
BEDROOM 2
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
BTHRM.
AutoCAD SHX Text
100mm soilpipe & ovp
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
85mm step
AutoCAD SHX Text
85mm step
AutoCAD SHX Text
100mm soilpipe & ovp
AutoCAD SHX Text
lintol over
AutoCAD SHX Text
DUCT NOTE: RE: SIM NOTE 1/T6
AutoCAD SHX Text
WALKWAY
AutoCAD SHX Text
DUCT NOTE: RE: SIM NOTE 1/T6
AutoCAD SHX Text
FIRE WALL TO U/S SLAB
AutoCAD SHX Text
COLUMN NOTE: RE: SIM NOTE 1/T6
AutoCAD SHX Text
door position varies REFER: BLOCK PLANS
AutoCAD SHX Text
2 BED / 1 BATH
AutoCAD SHX Text
TOTAL:
AutoCAD SHX Text
UNIT:
AutoCAD SHX Text
75,05m2
AutoCAD SHX Text
AREA
AutoCAD SHX Text
COV. PATIO:
AutoCAD SHX Text
9,51m2
AutoCAD SHX Text
65,54m2
AutoCAD SHX Text
m
AutoCAD SHX Text
f
AutoCAD SHX Text
ex
AutoCAD SHX Text
st
AutoCAD SHX Text
for balustrade positions REFER: BLOCK PLANS
AutoCAD SHX Text
500mm extension on ground floor only
AutoCAD SHX Text
LOUNGE
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
sink
AutoCAD SHX Text
dw
AutoCAD SHX Text
wm
AutoCAD SHX Text
refer kitchen layout for exact location of appliances
AutoCAD SHX Text
TERRACE
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
bic
AutoCAD SHX Text
bic
AutoCAD SHX Text
bath
AutoCAD SHX Text
wc
AutoCAD SHX Text
van
AutoCAD SHX Text
shr
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
BEDROOM 1
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
BEDROOM 2
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
BTHRM.
AutoCAD SHX Text
100mm soilpipe & ovp
AutoCAD SHX Text
85mm step
AutoCAD SHX Text
85mm step
AutoCAD SHX Text
100mm soilpipe & ovp
AutoCAD SHX Text
lintol over
AutoCAD SHX Text
DUCT NOTE: RE: SIM NOTE 1/T6
AutoCAD SHX Text
WALKWAY
AutoCAD SHX Text
DUCT NOTE: RE: SIM NOTE 1/T6
AutoCAD SHX Text
FIRE WALL TO U/S SLAB
AutoCAD SHX Text
door position varies REFER: BLOCK PLANS
AutoCAD SHX Text
m
AutoCAD SHX Text
f
AutoCAD SHX Text
ex
AutoCAD SHX Text
st
AutoCAD SHX Text
up
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
bic
AutoCAD SHX Text
shr
AutoCAD SHX Text
bath
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
BEDROOM 3
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
BTHRM. 3
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
OPEN TERRACE
AutoCAD SHX Text
PERGOLA NOTE: RE: SIM NOTE 3/A11
AutoCAD SHX Text
BALUSTRADE NOTE: RE: SIM NOTE 1/A11
AutoCAD SHX Text
ROOF NOTE 1: RE: SIM NOTE 3/A09
AutoCAD SHX Text
fall
AutoCAD SHX Text
fall
AutoCAD SHX Text
fall
AutoCAD SHX Text
fall
AutoCAD SHX Text
fall
AutoCAD SHX Text
HOPPER NOTE: RE: SIM NOTE 3/A09
AutoCAD SHX Text
stormwater overflow pipe
AutoCAD SHX Text
100mm soilpipe & ovp
AutoCAD SHX Text
lintol over
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
COVERED TERRACE
AutoCAD SHX Text
FIRE WALL TO U/S ROOF
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
STAIRCASE NOTE: RE: SIM NOTE 1/T6
AutoCAD SHX Text
2
AutoCAD SHX Text
STAIRCASE NOTE: RE: SIM NOTE 2/T6
AutoCAD SHX Text
PERGOLA NOTE: RE: SIM NOTE 3/T6
AutoCAD SHX Text
BALUSTRADE NOTE: RE: SIM NOTE 2/T6
AutoCAD SHX Text
ROOF NOTE 1: RE: SIM NOTE 3/A09
AutoCAD SHX Text
CORBEL NOTE: RE: SIM NOTE 3/A09
AutoCAD SHX Text
TOTAL:
AutoCAD SHX Text
UNIT:
AutoCAD SHX Text
AREA
AutoCAD SHX Text
COV. PATIO:
AutoCAD SHX Text
LOFT:
AutoCAD SHX Text
26,64m2
AutoCAD SHX Text
TOTAL:
AutoCAD SHX Text
119,86m2
AutoCAD SHX Text
TERRACE:
AutoCAD SHX Text
20,41m2
AutoCAD SHX Text
72,81m2
AutoCAD SHX Text
7,27m2
AutoCAD SHX Text
65,54m2
AutoCAD SHX Text
OVER 2 BED / 1 BATH
AutoCAD SHX Text
3 BED / 2 BATH
AutoCAD SHX Text
LOUNGE
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
balustrade wall with full height TV wall
AutoCAD SHX Text
door as an option
AutoCAD SHX Text
wc
AutoCAD SHX Text
van
AutoCAD SHX Text
st
AutoCAD SHX Text
fr
AutoCAD SHX Text
sink
AutoCAD SHX Text
dw
AutoCAD SHX Text
wm
AutoCAD SHX Text
ext
AutoCAD SHX Text
refer kitchen layout for exact location of appliances
AutoCAD SHX Text
WALKWAY
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
LOUNGE
AutoCAD SHX Text
bic
AutoCAD SHX Text
bath
AutoCAD SHX Text
85mm step
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
lintol above
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
BEDROOM
AutoCAD SHX Text
BTHRM.
AutoCAD SHX Text
wc
AutoCAD SHX Text
shr
AutoCAD SHX Text
van
AutoCAD SHX Text
fr
AutoCAD SHX Text
wm
AutoCAD SHX Text
sink
AutoCAD SHX Text
FIRE WALL TO U/S SLAB
AutoCAD SHX Text
FIRE WALL TO U/S SLAB
AutoCAD SHX Text
85mm step
AutoCAD SHX Text
st
AutoCAD SHX Text
BALCONY
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
COLUMN NOTE: RE: SIM NOTE 1/T6
AutoCAD SHX Text
100mm soilpipe & ovp
AutoCAD SHX Text
DUCT NOTE: RE: SIM NOTE 1/T6
AutoCAD SHX Text
100mm soilpipe & ovp
AutoCAD SHX Text
DUCT NOTE: RE: SIM NOTE 1/T6
AutoCAD SHX Text
for balustrade positions REFER: BLOCK PLANS
AutoCAD SHX Text
53,68m2
AutoCAD SHX Text
COV. PATIO:
AutoCAD SHX Text
AREA
AutoCAD SHX Text
1 BED / 1 BATH
AutoCAD SHX Text
TOTAL:
AutoCAD SHX Text
UNIT:
AutoCAD SHX Text
6,50m2
AutoCAD SHX Text
47,18m2
AutoCAD SHX Text
500mm extension on ground floor only
AutoCAD SHX Text
linen
AutoCAD SHX Text
f
AutoCAD SHX Text
ex
AutoCAD SHX Text
st
AutoCAD SHX Text
m
AutoCAD SHX Text
refer kitchen layout for exact location of appliances
AutoCAD SHX Text
wm
AutoCAD SHX Text
shr
AutoCAD SHX Text
lintol over
AutoCAD SHX Text
85mm step
AutoCAD SHX Text
bic
AutoCAD SHX Text
sink
AutoCAD SHX Text
st
AutoCAD SHX Text
fr
AutoCAD SHX Text
van
AutoCAD SHX Text
bath
AutoCAD SHX Text
wc
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
BEDROOM 1
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
BTHRM.11
AutoCAD SHX Text
shr
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
BTHRM. 2
AutoCAD SHX Text
FIRE WALL TO U/S SLAB
AutoCAD SHX Text
PERGOLA NOTE: RE: SIM NOTE 3/A11
AutoCAD SHX Text
BALUSTRADE NOTE: RE: SIM NOTE 2/T6
AutoCAD SHX Text
100mm soilpipe & ovp
AutoCAD SHX Text
DUCT NOTE: RE: SIM NOTE 1/T6
AutoCAD SHX Text
100mm soilpipe & ovp
AutoCAD SHX Text
up
AutoCAD SHX Text
1
AutoCAD SHX Text
5
AutoCAD SHX Text
9
AutoCAD SHX Text
8
AutoCAD SHX Text
100mm soilpipe & ovp
AutoCAD SHX Text
100mm soilpipe & ovp
AutoCAD SHX Text
FIRE WALL TO U/S SLAB
AutoCAD SHX Text
HOPPER NOTE: RE: SIM NOTE 3/A09
AutoCAD SHX Text
1
AutoCAD SHX Text
5
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
BALCONY
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
lintol over
AutoCAD SHX Text
bath
AutoCAD SHX Text
wc
AutoCAD SHX Text
van
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
BEDROOM 2
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
COVERED TERRACE
AutoCAD SHX Text
FIRE WALL TO U/S SLAB
AutoCAD SHX Text
32,73m2
AutoCAD SHX Text
WALKWAY
AutoCAD SHX Text
94,81m2
AutoCAD SHX Text
TERRACE:
AutoCAD SHX Text
DUCT NOTE: RE: SIM NOTE 1/T6
AutoCAD SHX Text
3
AutoCAD SHX Text
6
AutoCAD SHX Text
4
AutoCAD SHX Text
2
AutoCAD SHX Text
7
AutoCAD SHX Text
concrete staircase to detail
AutoCAD SHX Text
BALUSTRADE NOTE: RE: SIM NOTE 2/T6
AutoCAD SHX Text
PERGOLA NOTE: RE: SIM NOTE 3/A11
AutoCAD SHX Text
DUCT NOTE: RE: SIM NOTE 1/T6
AutoCAD SHX Text
DUCT NOTE: RE: SIM NOTE 1/T6
AutoCAD SHX Text
FIRE WALL TO U/S SLAB
AutoCAD SHX Text
4
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
6
AutoCAD SHX Text
10
AutoCAD SHX Text
8
AutoCAD SHX Text
12
AutoCAD SHX Text
9
AutoCAD SHX Text
7
AutoCAD SHX Text
11
AutoCAD SHX Text
concrete staircase to detail
AutoCAD SHX Text
15
AutoCAD SHX Text
TOTAL:
AutoCAD SHX Text
COV. PATIO:
AutoCAD SHX Text
LOFT:
AutoCAD SHX Text
UNIT:
AutoCAD SHX Text
AREA
AutoCAD SHX Text
51,67m2
AutoCAD SHX Text
TOTAL:
AutoCAD SHX Text
2 BED / 2 BATH
AutoCAD SHX Text
47,18m2
AutoCAD SHX Text
10,41m2
AutoCAD SHX Text
4,49m2
AutoCAD SHX Text
OVER 1 BED / 1 BATH
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
LOUNGE
AutoCAD SHX Text
bic
AutoCAD SHX Text
f
AutoCAD SHX Text
ex
AutoCAD SHX Text
st
AutoCAD SHX Text
m
AutoCAD SHX Text
ext
AutoCAD SHX Text
85mm step
AutoCAD SHX Text
refer kitchen layout for exact location of appliances
AutoCAD SHX Text
2016-04-13
AutoCAD SHX Text
issued for PRELIMINARY
AutoCAD SHX Text
TM
AutoCAD SHX Text
A
AutoCAD SHX Text
re-issued for INFORMATION
AutoCAD SHX Text
2016-04-19
AutoCAD SHX Text
general revisions made as per client/interior meeting
AutoCAD SHX Text
RA
AutoCAD SHX Text
B
AutoCAD SHX Text
CONSULTANT/REFERENCE DRAWING INDEX
AutoCAD SHX Text
REV
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
DRAWING No.
AutoCAD SHX Text
DISCIPLINE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
NOTE: contractor to check all dimensions on site and on drawings, any discrepancies must be reported to the architect. only figured dimensions are to be taken. This drawing is the property of E2 Architects + Urban Designers. copyright is reserved by them and the drawing is issued on the condition that it is not amended, copied, reproduced, retained or disclosed to any unauthorised person, either wholly or in part without the written consent of E2 Architects + Urban Designers. All work to comply with NATIONAL BUILDING REGULATIONS ACT 103 OF 1977 and the latest edition of the SANS 10400 and any amendments thereto as well as the by-laws of the relevant local municipality These drawings are to be read in conjunction with structural engineer's, civil engineer's, or plumbing consultant's drawings where specified ROOFS:(in accordance with PART L of SANS 10400) (in accordance with PART L of SANS 10400) refer to sections and structural engineer's drawings where specified all roof fixings to be in accordance with PART K of SANS 10400 WALLS:(in accordance with PART K of SANS 10400) (in accordance with PART K of SANS 10400) refer to sections, provide brickforce every fifth course CEILINGS & CILLS: refer to sections D.P.C's: SABS approved throughout D.P.M's: (in accordance with PART J of SANS 10400) SABS approved throughout STRUCTURAL WORK: refer to structural engineer's details and specifications GLAZING: (in accordance with PART N of SANS 10400) SANS 10137 and 1263-1 1263-1 DRAINAGE: (in accordance with PART P of SANS 10400) SABS materials used throughout. 75mm deep seal traps used with with all waste fittings. all i.e's to be marked at the surface and sealed. WC's to have and sealed. WC's to have "S" or "P" traps with side access cleaning eyes. all WHB"s to have 32 diam. cleaning eyes. all WHB"s to have 32 diam. waste pipes and 40 dia. waste pipes to all other fittings dia. waste pipes to all other fittings GENERAL NOTES: all habitable rooms to have a minimum of 10% natural light and 5% natural ventilation to comply with the NATIONAL BUILDING REGULATIONS (SANS 10400) unless otherwise specified, refer to mechanical engineer's specification. all openings to have prestressed lintols over. brickforce to every course for 5 courses above lintol, brickforce to every fifth course of brickwork use figured dimensions only, do not scale off drawing
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
JOB No.
AutoCAD SHX Text
DRAWING No.
AutoCAD SHX Text
REV.
AutoCAD SHX Text
PAGE SIZE
AutoCAD SHX Text
A1
AutoCAD SHX Text
1:50
AutoCAD SHX Text
RA
AutoCAD SHX Text
2016-03-28
AutoCAD SHX Text
2016-05-12
AutoCAD SHX Text
electrical layouts added to floor plans
AutoCAD SHX Text
RA
AutoCAD SHX Text
C
Page 3: NGL NGL - tnd.co.za · INSULATION NOTE: 135mm thick thermal and acoustic insulation . SLAB EDGE NOTE: concrete slab edge for plaster and paint finish as per spec. 85mm step. ROOF

2 BED / 2 BATH

TOTAL: 125,06m2

AREA

4

2

2

9

9

2

2

2

8

8

4

1

2a

3

22

2

2

4

SECTION A

T54

T52

T53

T55

SECTION A

T54

T52

T53

T55

T54

T52

T53

T55

SECTION A SECTION A SECTION A SECTION A

3

SCALE 1:100GROUND FLOOR PLAN1 SCALE 1:100

FIRST FLOOR PLAN2 SCALE 1:100ROOF PLAN3

67 7th street linden johannesburgtel: 011 782 1860

DRA

WIN

G T

ITLE

PR

OJE

CT

CT41604

FLOOR PLANSDUPLEX TYPE B - 2 BED/ 2 BATH

BRYANSTON EXT.7on ERVEN 3495,3496,3497

NEW TOWNHOUSES

AutoCAD SHX Text
GROUND FLOOR:
AutoCAD SHX Text
COV. PATIO:
AutoCAD SHX Text
8,61m2
AutoCAD SHX Text
FIRST FLOOR:
AutoCAD SHX Text
45,46m2
AutoCAD SHX Text
51,36m2
AutoCAD SHX Text
SINGLE GARAGE:
AutoCAD SHX Text
19,63m2
AutoCAD SHX Text
LOUNGE
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
COVERED PATIO
AutoCAD SHX Text
GARAGE
AutoCAD SHX Text
sink
AutoCAD SHX Text
dw
AutoCAD SHX Text
wm/td
AutoCAD SHX Text
up
AutoCAD SHX Text
DINING
AutoCAD SHX Text
st
AutoCAD SHX Text
GUEST WC
AutoCAD SHX Text
wc
AutoCAD SHX Text
whb
AutoCAD SHX Text
fr/fz
AutoCAD SHX Text
HALL
AutoCAD SHX Text
counter
AutoCAD SHX Text
braai
AutoCAD SHX Text
BEDROOM 1
AutoCAD SHX Text
LANDING
AutoCAD SHX Text
BATHRM 2
AutoCAD SHX Text
bic
AutoCAD SHX Text
van
AutoCAD SHX Text
bath
AutoCAD SHX Text
shr
AutoCAD SHX Text
wc
AutoCAD SHX Text
BATHRM 1
AutoCAD SHX Text
shr
AutoCAD SHX Text
van
AutoCAD SHX Text
wc
AutoCAD SHX Text
bic
AutoCAD SHX Text
high level
AutoCAD SHX Text
OPTION
AutoCAD SHX Text
BAY WINDOW
AutoCAD SHX Text
BEDROOM 2
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
FIRE WALL TO U/S SLAB
AutoCAD SHX Text
FIRE WALL TO U/S SLAB
AutoCAD SHX Text
fall
AutoCAD SHX Text
fall
AutoCAD SHX Text
85mm step
AutoCAD SHX Text
(tiles)
AutoCAD SHX Text
ie
AutoCAD SHX Text
re
AutoCAD SHX Text
ie
AutoCAD SHX Text
re
AutoCAD SHX Text
ie
AutoCAD SHX Text
to municipal connection point
AutoCAD SHX Text
100mm soil
AutoCAD SHX Text
pipe & ovp
AutoCAD SHX Text
DUCT NOTE:
AutoCAD SHX Text
350mm x 230mm
AutoCAD SHX Text
drainage duct with fibre
AutoCAD SHX Text
cement duct cover
AutoCAD SHX Text
100mm soilpipe & ovp
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
counter
AutoCAD SHX Text
(grano)
AutoCAD SHX Text
fall
AutoCAD SHX Text
fall
AutoCAD SHX Text
170mm step
AutoCAD SHX Text
170mm step
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
100 sewer line @ min 1:60 fall and min 450mm below NGL to mun. conn. pt.
AutoCAD SHX Text
lintol above
AutoCAD SHX Text
STAIR NOTE:
AutoCAD SHX Text
16 risers @ 180mm
AutoCAD SHX Text
15 treads @ 300mm
AutoCAD SHX Text
100mm soilpipe & ovp
AutoCAD SHX Text
DUCT NOTE:
AutoCAD SHX Text
BALUSTRADE NOTE: 1m high purpose made steel balustrade to later detail max 100c/c openings
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
line of roof above
AutoCAD SHX Text
JETMASTER braai or similar approved
AutoCAD SHX Text
fall
AutoCAD SHX Text
fall
AutoCAD SHX Text
fall
AutoCAD SHX Text
fall
AutoCAD SHX Text
fall
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
FIRE WALL TO U/S SLAB
AutoCAD SHX Text
line of roof above
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
ie
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
dashed line indicates
AutoCAD SHX Text
adjecent unit + garage
AutoCAD SHX Text
dashed line indicates
AutoCAD SHX Text
adjecent unit + garage
AutoCAD SHX Text
dashed line indicates
AutoCAD SHX Text
adjecent unit + garage
AutoCAD SHX Text
RE: SIM NOTE 1/T4
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
fall
AutoCAD SHX Text
g
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
fall
AutoCAD SHX Text
garden wall
AutoCAD SHX Text
STAIR CONSTRCUTION NOTE: timber/steel stringer fixed to brickwork with timber treads. Brick and lintol treads over storeroom for tile finish
AutoCAD SHX Text
mild steel balustrade for paint finish
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
rwdp
AutoCAD SHX Text
ex
AutoCAD SHX Text
st
AutoCAD SHX Text
f
AutoCAD SHX Text
m
AutoCAD SHX Text
AC
AutoCAD SHX Text
AC
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
AC
AutoCAD SHX Text
condenser
AutoCAD SHX Text
condenser
AutoCAD SHX Text
condenser
AutoCAD SHX Text
heap pump and condenser to sit one above the other
AutoCAD SHX Text
CEILING NOTE: garage to have 12,7mm fire rated ceiling
AutoCAD SHX Text
2016-04-13
AutoCAD SHX Text
issued for PRELIMINARY
AutoCAD SHX Text
TM
AutoCAD SHX Text
A
AutoCAD SHX Text
re-issued for INFORMATION
AutoCAD SHX Text
2016-04-19
AutoCAD SHX Text
general revisions made as per client/interior meeting
AutoCAD SHX Text
RA
AutoCAD SHX Text
B
AutoCAD SHX Text
2016-05-06
AutoCAD SHX Text
added electrical layout, added fire door and fire note
AutoCAD SHX Text
RA
AutoCAD SHX Text
C
AutoCAD SHX Text
CONSULTANT/REFERENCE DRAWING INDEX
AutoCAD SHX Text
REV
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
DRAWING No.
AutoCAD SHX Text
DISCIPLINE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
DATE
AutoCAD SHX Text
NOTE: contractor to check all dimensions on site and on drawings, any discrepancies must be reported to the architect. only figured dimensions are to be taken. This drawing is the property of E2 Architects + Urban Designers. copyright is reserved by them and the drawing is issued on the condition that it is not amended, copied, reproduced, retained or disclosed to any unauthorised person, either wholly or in part without the written consent of E2 Architects + Urban Designers. All work to comply with NATIONAL BUILDING REGULATIONS ACT 103 OF 1977 and the latest edition of the SANS 10400 and any amendments thereto as well as the by-laws of the relevant local municipality These drawings are to be read in conjunction with structural engineer's, civil engineer's, or plumbing consultant's drawings where specified ROOFS:(in accordance with PART L of SANS 10400) (in accordance with PART L of SANS 10400) refer to sections and structural engineer's drawings where specified all roof fixings to be in accordance with PART K of SANS 10400 WALLS:(in accordance with PART K of SANS 10400) (in accordance with PART K of SANS 10400) refer to sections, provide brickforce every fifth course CEILINGS & CILLS: refer to sections D.P.C's: SABS approved throughout D.P.M's: (in accordance with PART J of SANS 10400) SABS approved throughout STRUCTURAL WORK: refer to structural engineer's details and specifications GLAZING: (in accordance with PART N of SANS 10400) SANS 10137 and 1263-1 1263-1 DRAINAGE: (in accordance with PART P of SANS 10400) SABS materials used throughout. 75mm deep seal traps used with with all waste fittings. all i.e's to be marked at the surface and sealed. WC's to have and sealed. WC's to have "S" or "P" traps with side access cleaning eyes. all WHB"s to have 32 diam. cleaning eyes. all WHB"s to have 32 diam. waste pipes and 40 dia. waste pipes to all other fittings dia. waste pipes to all other fittings GENERAL NOTES: all habitable rooms to have a minimum of 10% natural light and 5% natural ventilation to comply with the NATIONAL BUILDING REGULATIONS (SANS 10400) unless otherwise specified, refer to mechanical engineer's specification. all openings to have prestressed lintols over. brickforce to every course for 5 courses above lintol, brickforce to every fifth course of brickwork use figured dimensions only, do not scale off drawing
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
JOB No.
AutoCAD SHX Text
DRAWING No.
AutoCAD SHX Text
REV.
AutoCAD SHX Text
PAGE SIZE
AutoCAD SHX Text
A1
AutoCAD SHX Text
1:100
AutoCAD SHX Text
TM
AutoCAD SHX Text
2016-03-25