    A new perspective for cost-efficient feeder protection

    Numerical design

    Integrated protection functions

    Four standard IDMT curves as per IEC

    Built-in measurement and fault

    recording functions

    Alphanumerical LCD display

    Reliability and availability due to

    internal self-supervision

    Freely configurable output contactsHigh immunity to electromagnetic interface

    Non-volatile memory for fault data

    Numerical Three Phase Overcurrent & Earth FaultRelay type NI 40 / 41

  • 8/4/2019 NI 40 Relay Flier

    2/2

    Technical Specifications NI 40 / 41 Series

    1HYT

    800001-503

    ABB Limited

    Distribution Automation

    Products

    Maneja,

    Vadodara 390 013 India

    Tel. : +91 265 2604384/5/6+91 265 2604397

    Fax : +91 265 2638922

    Email: [email protected]

    www.abb.co.in

    th4 Floor

    NBCC Tower No.15Bhikaji Cama PlaceNew Delhi 110 066

    Tel: +91 11-6186000Fax: +91 11-6197592/84035

    North

    rd

    3 Floor,No. 9,Lala Lajpat Rai Sarani,(Elgin Road)Kolkatta 700 020Tel: +91 33-2479162/8015Fax: +91 33-2472427

    East

    ABB HouseDr. S.B. PathBallard EstateMumbai 400 038Tel.+91 22-56318231-39Fax:+91 22-56318276-77

    West

    Vandana House1st Floor, G. E. RoadRamkundRaipur 492 001Tel: +91 771-660816-18Fax: +91 771-653391

    Central

    Embassy Star,st

    1 Floor, No.8, Place Road,Vasanth NagarBangalore-560052Tel: +91 80-2256315/16Fax: +91 80-2254147

    South

    Nos. 3C, 3D and 3F3 Floor, "Century Plaza"561 / 562, Anna SalaiTeynampetChennai - 600 018Tel: +91 44-4340201/203Fax: +91 44-4340282

    Regional Marketing Offices:

    ANSIProtection functions

    51

    50

    51N

    50N

    Three-phase over current protection, low-set stage ( IDMT or DT )

    Three-phase over current protection, high-set stage ( DT )

    Earth fault protection, low-set stage ( IDMT or DT )

    Earth fault protection, high-set stage ( DT )

    Site selectable IDMT curves for low set stage

    Four standard IDMT curves ( NI, VI, EI, LI ) as per IEC standard

    Wide and accurate numerical settings with perfect long time stability

    Latest five fault data recording

    Measurement, monitoring and recording functions

    Measurement of 3 phase current in primary or secondary terms

    Measurement of neutral current in primary or secondary terms

    Extensive relay internal self supervision monitoring relay hardware and software

    Trip lockout function

    2 x 16 digit backlit LCD display

    Control supply on, fault start / trip, relay internal failure indication LED's

    Display of fault cause indication

    Display and indications

    Four accurate current inputs

    Normally open heavy duty output contact

    Two change over signalling output contacts

    Freely configurable output contacts

    Dedicated output contact for relay internal self supervision

    Low burden on current transformer

    Design immune to any kind of electromagnetic interference

    Inputs and outputs

    Relay design

    Dimensions : 176 ( H ) x 146 ( W ). Depth behind panel only 158 mm

    Relay case with a degree of protection according to IP54

    Design confirming to requirements of IEC 60255 / IS 3231 standards

    Relay application

    For earth-fault protection in solidly earthed, resistance earthed and isolatedneutral networks

    industrial applicationsFor protection of transformers, capacitor banks, feeders of utility and

    For selective short-circuit and time-over current protection of distributionnetworks

    Connection diagram