7/30/2019 NI386X Evaluation kit manual v1.2.pdf
1/16
NI3862 / NI3864 Evaluation kit manual
ISDB-T NIM with IF output for analogue TV reception
D. Rehle/T. Pillmeier
24/04/09
Index 1.2
The information contained in this document is proprietary toTHOMSON and should not be disclosed by the recipient tothird persons without the written permission of THOMSON.
7/30/2019 NI386X Evaluation kit manual v1.2.pdf
2/16
NI3862 / NI3864 Evaluation kit manual
24/04/09
NI386X Evaluation kit manual v1.2.doc Page 2 / 16
Table of content
1. Introduction....................................................................................................... 32. Evaluation kit content ...................................................................................... 43. Software installation......................................................................................... 54. Operation........................................................................................................... 74.1 ISDB-T mode...................................................................................................... 74.2 Analogue TV mode ............................................................................................. 95. Software features............................................................................................ 105.1 ISDB-T demodulator control ............................................................................. 105.1.1 IQ, BER, MER Setting ..................................................................................125.1.2 TS Output Setting ......................................................................................... 125.2 Tuner control..................................................................................................... 135.2.1 Tuner standard mode ................................................................................... 135.2.2 Tuner expert mode ....................................................................................... 145.3 IC interface ...................................................................................................... 146. Contacts .......................................................................................................... 157. History ............................................................................................................. 16
7/30/2019 NI386X Evaluation kit manual v1.2.pdf
3/16
NI3862 / NI3864 Evaluation kit manual
24/04/09
NI386X Evaluation kit manual v1.2.doc Page 3 / 16
1. Introduction
NI386X with tuner, ISDB-T demodulator and IF output for analogue TV
The NI386X is an ISDB-T NIM. It is intended for the Brazil market.
With the evaluation kit it is possible to demonstrate the function and the performance of the
NI386X for ISDB-T reception. An additional test board option is an analogue demodulator todemonstrate the function and the performance in analogue TV mode.
First the evaluation software must be installed. After that the hardware can be connected.
7/30/2019 NI386X Evaluation kit manual v1.2.pdf
4/16
NI3862 / NI3864 Evaluation kit manual
24/04/09
NI386X Evaluation kit manual v1.2.doc Page 4 / 16
2. Evaluation kit content
Evaluation board with NI386X and analogue demodulator
Power supply cable
IC interface
IC cable
Evaluation software version 1.0 or higher NI386X specification
Test board schematic
7/30/2019 NI386X Evaluation kit manual v1.2.pdf
5/16
NI3862 / NI3864 Evaluation kit manual
24/04/09
NI386X Evaluation kit manual v1.2.doc Page 5 / 16
3. Software installation
Double click the file setup.exein the path NI386Xv1_4\cvidistkit.NI386X_v1_5of your CD
ROM drive. Follow the next steps:
Press Next
change path and Press Next
Press I accept and then Next
7/30/2019 NI386X Evaluation kit manual v1.2.pdf
6/16
NI3862 / NI3864 Evaluation kit manual
24/04/09
NI386X Evaluation kit manual v1.2.doc Page 6 / 16
Press Next
Press Finish
Ni3862v1_0
This shortcut appears at your desktop
and in the Start menu Programs
NuTune NI3862v1_0
7/30/2019 NI386X Evaluation kit manual v1.2.pdf
7/16
NI3862 / NI3864 Evaluation kit manual
24/04/09
NI386X Evaluation kit manual v1.2.doc Page 7 / 16
4. Operation
Test board with NI386X for ISDB-T with option for analogue TV reception
4.1 ISDB-T mode
Jumper BA10: Connection between jumper pins 3 and 4
Jumper BA11: Open
Connect RF ISDB-T signal to the antenna connector 1
Connect the IC bus interface with connector 10 and the computer parallel port(LPT1)
Connect 6,5V DC to power supply connector 11 (Power on LED at the testboard is on)
Reset the module with key 8
Start the software with a double click at the shortcut on the desktop (The panelon the next page appears)
Select the required frequency
The demodulator is locking (no red indicators, Lock LED at the test board ison)
If required a picture test can be done. Connect the monitor equipment with theLVDS-connector 9.
The ERROR LED on the test board is an indicator for uncorrectable packeterrors
5V Antenna power can be provided if the antenna power jumper is in on-position (Be careful, this feature can damage your measurement equipment)
33
44
55 66 77
88
22
11
99
1111
1100
7/30/2019 NI386X Evaluation kit manual v1.2.pdf
8/16
NI3862 / NI3864 Evaluation kit manual
24/04/09
NI386X Evaluation kit manual v1.2.doc Page 8 / 16
NI386X software after start up with lock to an ISDB-T signal
7/30/2019 NI386X Evaluation kit manual v1.2.pdf
9/16
NI3862 / NI3864 Evaluation kit manual
24/04/09
NI386X Evaluation kit manual v1.2.doc Page 9 / 16
4.2 Analogue TV mode
There is an analogue demodulator test board option to provide very efficient analogue
reception investigations.
Jumper BA10: Connection between jumper pins 3 and 4
Jumper BA11: Set
Connect RF analogue TV signal (Standard M or standard N) to the antennaconnector 1
Connect an TV with an CVBS-video input to the connector 4 Connect the IC bus interface with connector 10 and the computer parallel port
(LPT1) Connect 6,5V DC to power supply connector 11 (Power on LED at the test
board is on) Reset the module with key 8
Start the software Deselect the check box Digitalin the tuner window (Analogappears instead of
Digitaland the digital demodulator window disappears)
Press the reset button in the software
Select the required frequency or the required channel
No indicator in the software should be red
The transmitted picture should appear on the screen
A mono audio signal is provided at connector 6
A Sound IF signal is provided at connector 5
5V Antenna power can be provided if the antenna power jumper is in on-position (Be careful, this feature can damage your measurement equipment)
Depending on the jumper position (BA10) the analogue demodulator can besupplied with an external IF signal 3 or the analogue IF can be monitored
7/30/2019 NI386X Evaluation kit manual v1.2.pdf
10/16
NI3862 / NI3864 Evaluation kit manual
24/04/09
NI386X Evaluation kit manual v1.2.doc Page 10 / 16
5. Software features
5.1 ISDB-T demodulator control
Lock: Green color indicates that an
ISDB-T signal has been detected
Demod Address: The demodulator IC
address can be selected depending on
the ADR0 (Pin 30) and ADR1 (Pin 31)
Mode: FFT size, Mode 3 = 8k FFT,
Mode 2 = 4k FFT and Mode 1 = 2k FFT
Guard: Detected guard interval
Emergency: Becomes red when
emergency signal is detected
Reset emergency: Press this button to
reset the XIRQ output into non
emergency state. Otherwise the XIRQ
output remains in emergency state
Transmission parameters:
Modulation, Code rate, Time interleaver
mode, Number of segments for each
layer
BER: Bit error rate pre Viterbi, after
Viterbi and detected packet errors
SNR: Signal to noise estimator
By clicking in the Post Viterby field Layer
A , B or C a additional window comes up
and show the post viterby and package
error over time in a display
7/30/2019 NI386X Evaluation kit manual v1.2.pdf
11/16
NI3862 / NI3864 Evaluation kit manual
24/04/09
NI386X Evaluation kit manual v1.2.doc Page 11 / 16
Thin blue line: Show post viterby
errors over the time.
Fat red line: Show packet errors
Fat orange line: limit for post viterby
errors. Could be changed through the
numeric control in the panel)
7/30/2019 NI386X Evaluation kit manual v1.2.pdf
12/16
NI3862 / NI3864 Evaluation kit manual
24/04/09
NI386X Evaluation kit manual v1.2.doc Page 12 / 16
5.1.1 IQ, BER, MER Setting
Application Digital Demodulator IQ, BER, MER Setting
IQ: Switches between normal mode and
spectrum inversion
RS: Reed Solomon decoder state
Segment: Switches between different 1 and 13
segment reception
BER Monitor Timer Setting: Number of data
for BER calculation
5.1.2 TS Output Setting
Application Digital Demodulator TS Output Setting
Sets the parameters for the digital transport
stream interface
7/30/2019 NI386X Evaluation kit manual v1.2.pdf
13/16
NI3862 / NI3864 Evaluation kit manual
24/04/09
NI386X Evaluation kit manual v1.2.doc Page 13 / 16
5.2 Tuner control
5.2.1 Tuner standard mode
Load: A frequency table in tab separated format
can be loaded. It is possible do modify this table
with a text editor.
Frequency: The required RF can be set. For
ISDB-T it is the channel center and analogue
reception it is the picture carrier frequency. If the
channel table is used the frequency of the
selected channel is displayed.
IF frequency: Displays the IF. For digital
reception it is the channel center and for
analogue reception the picture carrier
frequency.
Stepsize: This value represents the reference frequency. The default value is
recommended.
Stepsize Large: Adjusts the step size for the arrows of the frequency input box. If Offis set
the smallest step size is used (Reference frequency).
AGC Threshold: This value represents the level at the IF detector when the RF-AGC starts
to control. The default value is recommended.
LOW/MID/HIGH: Indicators for the used tuner band
Reception: Switches between analogue and digital reception. For analogue reception the
ISDB-T demodulator is in stand by mode.
I2C-Bus indicators: Shows the status of the tuner IC bus. No indicator should be red.
7/30/2019 NI386X Evaluation kit manual v1.2.pdf
14/16
NI3862 / NI3864 Evaluation kit manual
24/04/09
NI386X Evaluation kit manual v1.2.doc Page 14 / 16
5.2.2 Tuner expert mode
Application Tuner Expert
These settings should be changed only by experienced users. It can deteriorate the tuner
performance. In the expert mode the charge pumps will not be set automatically.
Charge pump: Manual charge pump control
Band / Standby: Manual band switch and tuner stand by
AGC Decay Current: Changes the time constant of the RF-AGC (Only for ISDB-T reception)
5.3 IC interface
IC Status: No indicator should be red. The IC speed can be changed
with the slider.
I/O Port: The parallel port address (LPT-Port) can be selected. In most
cases 0x378 is the right value.
7/30/2019 NI386X Evaluation kit manual v1.2.pdf
15/16
NI3862 / NI3864 Evaluation kit manual
24/04/09
NI386X Evaluation kit manual v1.2.doc Page 15 / 16
6. Contacts
NuTune Europe / USA
Gerd Siegel
VRF-Lab Villingen
Tel. (49) 7721 85 2263
Fax (49) 7721 85 2230
E-mail [email protected]
NuTune Asia
Joke Tin Goh
SLH-Lab Singapore
Tel. (65) 63791404
Fax (65) 6371775E-mail [email protected]
7/30/2019 NI386X Evaluation kit manual v1.2.pdf
16/16
NI3862 / NI3864 Evaluation kit manual
24/04/09
NI386X Evaluation kit manual v1.2.doc Page 16 / 16
History
Date ofChanges
Index Modification Pages
31-07-08 0 Creation07-08-08 1 Contacts added27-11-08 1.1 Change name and logo all11-12-08 1.1 Change image 624-04-09 1.2 Update from NI3860 to NI3862 all