2
NITROGEN-GENERATOR IMT-PN OnTouch PSA-TECHNOLOGY ^ NITROGEN GENERATION WITH “PRESSURE SWING ADSORPTION” UP TO 99,9999% (6.0) / 1.0 PPM (RESIDUAL O 2 ) ^ INMATEC OnTouch technology enables nitrogen to be supplied in a purity of up to 6.0/1.0 ppm (residual oxygen) and quantities of 0.5 – 10,000 Nm³/h. PERMANENT N 2 SUPPLY PROCESS: The production of high-purity to ultra-pure nitrogen is what makes INMATEC PSA nitrogen generators stand out. In this process, the clean com- pressed air flows through the adsorption containers. In this pressure swing adsorption process, the high-quality activated carbon binds the oxygen molecules, while the free nitrogen molecules flow unhindered into the product tank. This production process removes carbon dioxide molecules as well as oxygen molecules. The dry and high-purity nitrogen can now be used in a wide range of applications. BENEFITS: Constant quality control is ensured by measuring nitrogen purity. All measured values are recorded on our user-friendly INMATEC touch control panel and can be monitored remotely from anywhere in the world with internet access. The effectiveness of the new technology promises savings from the very first minute. Low-maintenance valve technology and compact design are further benefits in addition to the constant availability of high-purity nitrogen. N 2 Measured values: • Flow • Pressure dew point • Inlet pressure • Temperature Options: Interfaces: • Modbus • Profibus • GSM • VMC Availability: • Redundant • Load change control • Modular extension • Recipe control High pressure: • up to 300 bar • System control ONSITE IS OUR WORLD ^ A multilingual touch control panel, remote control via PC and iPad, long-term data storage and inlet and outlet filtration all come as standard. MADE IN GERMANY www.CompressedAirSystems.com

NITROGEN-GENERATOR IMT-PN OnTouchcatalog.compressedairsystems.com/Asset/IMT_Flyer_PN-OnTouch_GB.pdfNITROGEN-GENERATOR IMT-PN O. nTouch ^ PSA-TECHNOLOGY. NITROGEN GENERATION WITH “PRESSURE

  • Upload
    others

  • View
    19

  • Download
    0

Embed Size (px)

Citation preview

Page 1: NITROGEN-GENERATOR IMT-PN OnTouchcatalog.compressedairsystems.com/Asset/IMT_Flyer_PN-OnTouch_GB.pdfNITROGEN-GENERATOR IMT-PN O. nTouch ^ PSA-TECHNOLOGY. NITROGEN GENERATION WITH “PRESSURE

NITROGEN-GENERATOR

IMT-PN OnTouch

PSA-TECHNOLOGY

^

NITROGEN GENERATION WITH “PRESSURE SWING ADSORPTION” UP TO 99,9999% (6.0) / 1.0 PPM (RESIDUAL O2)

^

INMATEC OnTouch technology enables nitrogen to be supplied in a purity of up to 6.0/1.0 ppm (residual oxygen) and quantities of 0.5 – 10,000 Nm³/h.

PERMANENT N2 SUPPLY

PROCESS:

The production of high-purity to ultra-pure nitrogen is what makes INMATEC PSA nitrogen generators stand out. In this process, the clean com-pressed air flows through the adsorption containers. In this pressure swing adsorption process, the high-quality activated carbon binds the oxygen molecules, while the free nitrogen molecules flow unhindered into the product tank. This production process removes carbon dioxide molecules as well as oxygen molecules. The dry and high-purity nitrogen can now be used in a wide range of applications.

BENEFITS:

Constant quality control is ensured by measuring nitrogen purity. All measured values are recorded on our user-friendly INMATEC touch control panel and can be monitored remotely from anywhere in the world with internet access. The effectiveness of the new technology promises savings from the very first minute.Low-maintenance valve technology and compact design are further benefits in addition to the constant availability of high-purity nitrogen.

N2

Measured values:

• Flow• Pressure dew point• Inlet pressure• Temperature

Options:

Interfaces:

• Modbus• Profibus• GSM• VMC

Availability:

• Redundant• Load change control• Modular extension• Recipe control

High pressure:

• up to 300 bar• System control

ONSITE IS OUR WORLD

^A multilingual touch control panel, remote control via PC and iPad, long-term data storage and inlet and outlet filtration all come as standard.

MADE IN GERMANY

www.CompressedAirSystems.com

Page 2: NITROGEN-GENERATOR IMT-PN OnTouchcatalog.compressedairsystems.com/Asset/IMT_Flyer_PN-OnTouch_GB.pdfNITROGEN-GENERATOR IMT-PN O. nTouch ^ PSA-TECHNOLOGY. NITROGEN GENERATION WITH “PRESSURE

95,0

All values apply at 7 bar inlet pressure and 20°C ambient temperature.

Capacity (Nm³/h)

IMT-PN 1150

IMT-PN 1250

IMT-PN 1280

IMT-PN 1350

IMT-PN 1450

IMT-PN 1550

IMT-PN 1650

IMT-PN 1750

IMT-PN 2000

IMT-PN 2150

IMT-PN 2250

IMT-PN 3000

IMT-PN 4000

IMT-PN 5000

IMT-PN 6000

IMT-PN 8000

IMT-PN 10.000

IMT-PN 12.000

IMT-PN 14.000

IMT-PN 16.000

IMT-PN 24.000

5,7

10,8

16,5

20,8

31,2

49,2

84,0

105,0

140,7

211,1

260,4

372,8

442,1

630,0

913,5

1370,3

1598,0

1827,0

2283,0

2740,6

4111,0

4,7

8,7

13,4

17,1

25,6

40,1

59,9

84,0

116,5

174,3

215,3

308,7

366,5

522,9

756,0

1134,0

1323,0

1512,0

1890,0

2268,0

3402,0

4,1

7,9

12,0

15,8

23,7

35,6

53,8

76,0

98,3

146,5

188,0

269,9

320,3

457,8

661,5

992,3

1157,0

1323,0

1653,0

1984,6

2976,9

3,2

5,8

9,0

12,6

18,9

28,4

46,6

64,0

77,5

115,0

143,9

205,8

244,7

348,6

504,0

756,0

882,0

1008,0

1260,0

1512,0

2268,0

2,6

5,1

7,7

9,5

14,2

22,1

37,8

51,8

63,0

94,5

116,6

167,0

198,5

283,5

409,5

630,0

724,0

819,0

1039,0

1260,0

1890,0

1,6

3,2

4,8

6,3

9,5

12,6

23,2

32,6

38,8

57,8

73,4

102,9

121,8

174,3

252,0

378,0

441,0

504,0

630,0

756,0

1134,0

0,9

1,3

2,4

3,2

4,8

6,3

11,7

16,5

19,4

29,0

35,8

51,4

60,9

87,2

126,0

189,0

220,0

252,0

315,0

378,0

567,0

0,7

1,1

1,8

2,5

3,6

4,8

8,8

11,9

14,6

21,8

26,9

38,6

45,8

65,4

94,5

142,0

165,0

189,0

236,0

284,0

426,0

0,40

0,90

1,30

1,80

2,40

3,20

5,80

7,30

9,70

14,50

18,00

25,80

30,60

43,60

63,00

95,0

110,0

126,0

158,0

190,0

285,0

Nitrogen content (%)QualityResidual O2 (PPM)

97,0 98,0 99,02,0

10.000

99,52,5

5.000

99,93,0

1.000

99,994,0

100

99,9954,550

99,9995,010

Calculation of the compressed air requirementsMultiplying the nitrogen capacity by the air factor indicated below gives the compressed air requirements.

Compressed air specificationTemperature range: +5 to +50°CAir quality: ISO 8573.1, Class 1: dirt and oil, Class 4: water Pressure dew point: +3°C

Technical dimensions and connectionsDimensions H x W x D (mm): 1285 x 438 x 920 (PN 1150 and PN 1250) 1665 x 460,5 x 1115 (PN 1280 up to PN 1450) from PN 1550 dimensions on request

Operating pressure: 11 bar max.Electrical connection: 110-230 V/60-50 Hz (shock-proof plug)Noise level: from 55 to max. 85 dB(A)

Special designStainless steel, explosion protection, Atex, IP 65, ASME

Ambient conditionsTemperature range: +5°C to +40°COption:Temperature range: -50°C to +60°C

NITROGEN-GENERATOR

IMT-PN OnTouch

PSA-TECHNOLOGY

^

Nitrogen content (%)

Air factor

95,00

1,9

97,00

2,1

98,00

2,3

99,00

2,5

99,50

2,9

99,90

3,9

99,99

5,5

99,999

8,0 -10

99,9999

10,0 -12,0

INMATEC GaseTechnologie GmbH & Co.KG

Gewerbestrasse 72 82211 Herrsching / Germany phone: +49.8152.90.97.0 fax: +49.8152.90.97.10 e-mail: [email protected] www.inmatec.com

ISO 9001:2008

Certified in accordance with ISO 9001:2008 and in accordance with Pressure Equipment Directive 93/27/EC

www.CompressedAirSystems.com