H I G H T E C H , E N E R G Y S AV I N G A I R C O N D I T I O N E R S , E N S U R I N G C O M F O R T

I N L I G H T C O M M E R C I A L A P P L I C AT I O N S

EPC08-201.indb 1 18-03-2008 09:47:20

Page 2: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

2

Air Conditioning and the EnvironmentAir conditioning systems provide a significant level of indoor comfort,making possible optimum working and living conditions in the mostextreme climates.In recent years, motivated by a global awareness of the need toreduce the burdens on the environment, some manufacturersincluding Daikin have invested enormous efforts in limiting thenegative effects associated with the production and the operation ofair conditioners.Hence, models with energy saving features and improved eco-production techniques have seen the light of day, making a significantcontribution to limiting the impact on the environment.

Daikin has a worldwide reputation based on over 80 years’ experiencein the successful manufacture of high quality air conditioningequipment for industrial, commercial and residential use.

Daikin Europe N.V.

EPC08-201.indb 2 18-03-2008 09:47:30

Page 3: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

3

INTRODUCTION 2

FEATURES 4

1. Wide Application Range 42. Environmental Awareness 103. Installation & Maintenance Friendly Design 11

OUTDOOR UNITS 13

1. VRV®III-S Technology 132. Specifications 153. Accessories 15

INDOOR UNITS 16

1. Features 162. Specifications & Accessories 23

VENTILATION 36

1. VAM-FA 362. VKM-GAM / VKM-GA 37

POWERFUL SELECTION PROGRAMMES 38

1. VRV® XPRESS 382. VRV® PRO 39

USER FRIENDLY CONTROL SYSTEMS 40

1. Individual Control Systems 402. Centralised Control Systems 423. Network Solutions 434. Accessories 48

EPC08-201.indb 3 18-03-2008 09:47:37

Page 4: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

4

VRV› ®III-S OUTDOOR UNIT RANGE

INDOOR UNIT CAPACITY INDEX›

eg. Selected indoor units:FXCQ25 + FXFQ50 + FXDQ25 + FXDQ50

Connection ratio: 25 + 50 + 25 + 50 = 150

Possible outdoor unit:RXYSQ5PAV1

RXYSQ4PAV1/RXYSQ4PAY1RXYSQ5PAV1/RXYSQ5PAY1RXYSQ6PAV1/RXYSQ6PAY1

®

9 Space saving

9 Small capacity

9 Slim design

9 Silent operation

9 Super wide range of indoor units

EPC08-201_1-22.indd 4 14-04-2008 10:32:18

Page 5: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

5

FLEXIBLE PIPING DESIGN›

The VRV®III-S provides the long piping lengthpossibility of 150m1 (175m equivalent piping length),with a total piping length of 300m. If the outdoorunit is installed above the indoor units, the heightdifference can be up to a maximum of 50m2.These generous allowances facilitate an extensivevariety of system designs.

Notes:1. 40 m when the outdoor unit is installed below indoor units.2. Maximum piping length between the indoor unit and the first

branch is 40 m.

WIDE OPERATION RANGE›

The VRVIII®-S system can be installed practicallyanywhere. The incorporation of a high pressure“dome” type compressor results in a remarkableoutdoor operating temperature range from as low as-20°C in heating mode to as high as 46°C in coolingmode.

SPACE SAVING DESIGN›

The VRVIII®-S is slimmer and more compact, resultingin significant savings in installation space.

Outdoor temperature operating range

Cooling46°CDB

Heating15.5°CWB

-5°CDB

-20°CWB

50

40

30

20

10

0

-10

-20

-30

FOOTPRINTApprox. 40%reduction

(4,5,6HP)

900mm

796mm

765m

m

320mm

VOLUMEApprox. 50%reduction

(5HP)

EPC08-201.indb 5 18-03-2008 09:47:49

Page 6: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

6

SUPER WIDE RANGE OF INDOOR UNITS›

Whatever the air conditioning requirement, a Daikin indoor unit can provide the solution. The VRV®III-S can be

combined with in a total of .

CASSETTE TYPE UNIT

CONCEALED CEILING UNIT

FLOOR STANDING UNIT

EPC08-201_1-22.indd 6 04-04-2008 16:27:28

Page 7: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

7

CONCEALED FLOOR STANDING UNIT

CEILING SUSPENDED UNIT

WALL MOUNTED UNIT

EPC08-201_1-22.indd 7 04-04-2008 16:27:40

Page 8: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

8

Step 1 max. - 3dB(4HP/11.2Kw)

Step 2 max. - 6dB(4HP/11.2Kw)

Step 3 max. - 9dB(4HP/11.2Kw)

Peak in the outdoor temperature

Night mode starts Night mode ends

Step 1: 47dB

Step 2: 44dB

Step 3: 41dB

Night Mode

8 hrs(initial setting)

10 hrs(initial setting)

— Operation Sound dBA

— Load %

— Capacity* %

Notes:This function is available for on site setting.›The relationship between outdoor temperature (load) and time shown›in the graph is merely an example.

SUPER SILENT OPERATION›

Quietness is another important feature. To reduce noise and ensure comfortable operation, the latest technologiesand features have been applied to the outdoor units.

During the night the sound level of the outdoor unit can be reduced for a certain period: starting time and endingtime can be input

2 modes*1 with low sound level at night:

Mode 1 Automatic mode›Set on the outdoor PCB. Time of maximum temperature is memorised. The low operating mode will become active8 hours*2 after the peak temperature in the daytime and operation will return to normal after 9 hours*3.

Mode 2 Customized mode›Starting and ending times can be input. (External control adapter for outdoor unit, DTA104A61 or DTA104A62and a separately ordered timer are necessary.)

Notes:*1. Determine which mode to select depending on the climatic characteristics of each country.*2. Initial setting. Can be selected from 6, 8 and 10 hours.*3. Initial setting. Can be selected from 8, 9 and 10 hours.

Night quiet function (max. -9dBA)

Daikin indoor units operate atsound levels as low as 25 dBA

(dB(A Perceived loudness Sound

0 Treshold of hearing -20 Extremely soft Rustling leaves40 Very soft Quiet room60 Moderately loud Normal conversation80 Very loud City traffic noise

100 Extremely loud Symphonic orchestra120 Threshold of feeling Jet taking off

Daikin indoor units

EPC08-201.indb 8 18-03-2008 09:48:08

Page 9: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

9

40 30 20 10 6 5 4 3 2 1

10

9

8

7

6

5

4

3

2

1

0

8

6

4

2

05 4 3 2 1

ANTI CORROSION TREATMENT›

Special anti corrosion treatment of the heat exchanger provides5 to 6 times greater resistance ag nst acid rainand salt corrosion. The use of rust proof steel sheet on the underside of the unit gives additional protection.

Improvement in corrosion resistance

Corrosion resistance rating

Non-treated Anti-corrosion treatedSalt corrosion 1 5 to 6

Acid rain 1 5 to 6

An anti-corrosion heat exchanger cutaway view

Aluminium

Hydrophilic film

Corrosion-resistantacrylic resin

Performed tests:

VDA Wechseltest›Contents of single cycle (7 days):- 24 hours salt spray test SS DIN 50021- 96 hours humidity cycle test KFW DIN 50017- 48 hours room temperature & room humidityTesting period: 5 cycles

Kesternich test (SO2)›- Contents of single cycle (48 hours) according

to DIN50018 (0.21)- Testing period: 40 cycles

Cycle

Deg

ree

of

Co

rro

sio

n

Cycle

Deg

ree

of

Co

rro

sio

n

.DAIKIN P.E

Barealuminium

Heat exchanger

EPC08-201.indb 9 18-03-2008 09:48:18

Page 10: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

10

HIGH COP VALUES›A major feature of VRV®III-S is its exceptional energy efficiency,the system achieving high COPs during both cooling and heatingoperation by the use of refined components and functions.

0 1 2 3 4 5

Heating

Nominal value

Cooling

1*3.99

2*4.56

Temperature remains stable

Slow start

Air conditioningwithout Inverter

Air conditioningwith Inverter

*1 Nominal cooling capacities are based on: indoor temperature: 27°CDB,19°CWB, inlet water temperature: 30°C, equivalent refrigerant piping: 7.5m,level difference: 0m.Unit: RXYSQ4PA7V1B

*2 Nominal heating capacities are based on: indoor temperature: 20°CDB,outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 7.5m,level difference: 0m.Unit: RXYSQ4PA7V1B

INVERTER CONTROL›

The application of inverter control saves energy for two basicreasons:

1. It enables compressor speed to vary according to the cooling/heating load and therefore consume only the power necessaryto match that load. The 50 Hz frequency of the power supply isinverted to a higher or lower frequency according to the requiredcapacity to heat or cool the room. If a lower capacity is needed,the frequency is decreased and less energy is used.

2. Under partial load conditions, the energy efficiency is higher.If the compressor rotates more slowly because less capacityis needed, the coil becomes virtually oversized. Improvedefficiencies can therefore be achieved than are possible withnon inverter compressors, which always run at the same speed.

EPC08-201_1-22.indd 10 04-04-2008 16:27:51

Page 11: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

11

32°C

20°C

0°C 43°C

AUTOMATIC CHARGE FUNCTION›

Conventional Way:›1. calculation of additional refrigerant charging volume2. charging the unit with additional refrigerant3. measuring the weight of the cylinder4. judgment based on pressure (test operation)

VRV› ®III-S:With VRV®III however, these 4 steps are omitted since VRVIII®-S canbe charged with the necessary amount of refrigerant automaticallyvia a push button on the PCB. Automatic charging will cease oncethe appropriate amount of refrigerant has been transferred.

If temperature drops below 20°C manual charging is necessary (toavoid overcharging the system). After having switched to heatingand once the indoor temperature rises above 20°C, push theauto charge button to initialise auto charge function. Refrigerantcontainment is only available after performing the automaticcharge function.

AUTOMATIC TEST›

When refrigerant charging has ceased, pushing the test operationbutton on the PCB will initiate a check on the wiring, shut off valves,sensors and refrigerant volume. This test ceases automatically whencompleted.

Indoor temperature

Outdoor temperature

*To avoid overcharging the system

Automaticcharge

function

Manualcharge*

EPC08-201_1-22.indd 11 04-04-2008 16:28:00

Page 12: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

12

SIMPLE WIRING AND PIPING CONNECTION›

– simple wiringSuper Wiring allows the shared use of wiring between indoor units,›outdoor units and the centralised remote controls.This system makes it easy for the user to retrofit the existing system›with a centralised remote control, simply by connecting it to theoutdoor units.The use of non polarity wiring, makes incorrect connection impossible›and reduces installation time.

– piping connectionThe unified Daikin REFNET piping system is specially designed for›simple installation.REFNET joints and headers (both accessories) can cut down on›installation work and increase system reliability.

EPC08-201.indb 12 18-03-2008 09:48:46

Page 13: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

N

S

N

NN

N

S SS

S

13

1 Smooth air inlet bell mouth and aero spiral fanThese features assist in significantly reducingnoise. Guides are added to the bell mouth intaketo reduce turbulence in the air flow generated byfan suction.The aero spiral fan features fan blades with bentblade edges, further reducing turbulence.

2 DC fan motorThe use of a DC fan motor offers substantialimprovements in operating efficiency comparedto conventional AC motors, especially during lowspeed rotation.

4 Reluctance brushless DC compressorThe reluctance brushless DC motor providessignificant increases in efficiency compared toconventional AC inverter motors, simultaneouslyusing two different forms of torque (normal andreluctance torque) to produce extra power fromsmall electric currents.

Powerful magnets›The motor comprises powerful neodymium magnetsthat create the reluctance torque. These magnets areapproximately 12 times stronger than ferrite typesand make a major contribution to its energy savingcharacteristics.

3 Super aero grilleThe spiral shaped ribs are aligned with the directionof discharge flow in order to minimise turbulenceand reduce noise.

Neodymiummagnet

Ferritemagnet

Low pressure side

High pressure side

Suction

Scroll

Dis-charge

Reluctance DCMotor

Neodymiummagnet Normal” torque”

Reluctance torque

Rotatingstator field

Iron

200 300 400 500 600 700 800 900 1000

100

80

60

40

20

0

Note:Data are based on studies conducted under controlled conditionsat a Daikin laboratory

DC fanmotor structure

magnet

DC motor efficiency(comparison with a conventional AC motor)

(%)

Effi

cien

cy

DC motor

Approx. 20%increase

AC motor

Approx. 40%increase

Motor speed (rpm)

Conventional New

Escaping edges are sucked in by the bent blade edges, reducingoverall turbulence.

Aero spiral fan blade tips

2

1

34

5

EPC08-201.indb 13 18-03-2008 09:48:51

Page 14: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

2

1

34

5

14

Smooth sine wave DC inverter›Optimizing the sine wave curve results in smoothermotor rotation and improved motor efficiency.

Optimal refrigerant configuration›Changes to the shape of the spiral and volume ratioresult in optimal refrigerant layout.

Stronger materials›The strength of the casing has been increased byboosting the internal dome pressure.

5 e-Bridge circuitPrevents accumulation of liquid refrigerant inthe condenser. This results in more efficient useof the condenser surface under all conditionsand leads in turn to better energy efficiency.Increased evaporative capacity stems from thenewly developed refrigeration circuit, the SCe-bridge circuit, which adds super cooling priorto the expansion cycle. By adopting this circuit,the COPs in both cooling and heating have beendrastically improved.

6 e-Pass heat exchangerOptimization of the layout path of the heatexchanger prevents heat transferring from theoverheated gas section towards the sub cooledliquid section, a more efficient use of the heatexchanger.

7 i-Demand functionThe newly introduced current sensor minimizesthe difference between actual power consumptionand predefined power consumption.

27°C

27°C

27°C

55°C 37°C 43°C

55°C 60°C

50°C 55°C

27°C

27°C

27°C

55°C

In cooling mode, the heat exchanger of the condensor is improved.This means an improvement of COP by 3%.

Current Model HD Type

OUT 45°C

OUT 45°C

IN 85°C OUT 45°CIN 85°C

Pow

erco

nsu

mp

tio

n(K

VV

)

8:00 12:00 16:00 20:00Time

Evaporative capacitycan be raised bytaking super coolingjust before theelectronicexpansion valve

By the SCe- bridgecircuit, cooling andheating attain theimprovement in COP

CurrentEvaporative-

capacity

Evaporative-capacity has been improved byadopting the SCe-Bridge Circuit circuit.

SCe-Bridge Circuit

EPC08-201_1-22.indd 14 21-04-2008 10:32:52

Page 15: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

15

RXYSQ4PA7V1B /RXYSQ4PA7Y1B RXYSQ5PA7V1B /RXYSQ5PA7Y1B RXYSQ6PA7V1B /RXYSQ6PA7Y1B

Nominal capacity cooling kWheating kW

COP coolingheating

Capacity range HPMax n° of indoor units to be connectedIndoor index connection minimum

maximumCasing colour

materialPower supply V3Dimensions unit height mm

width mmdepth mm

Weight unit kgFan type

air Flow Rate cooling m/min(nominal at 230V) heating m/min

Compressor typestarting method

Operation range cooling minimum °CDBmaximum °CDB

heating minimum °CWBmaximum °CWB

Sound level (nominal) cooling sound power dBAsound pressure dBA

heating sound pressure dBARefrigerant type

charge kgcontrol

Refrigerant Oil typecharged Volume l

Piping Connections liquid diameter (OD) mmgas diameter (OD) mmheat Insulationmax. total length m

Safety devices

11.2 14.0 15.512.5 16.0 18.0

3.99 / 3.88 3.99 / 3.88 3.42/ 3.334.56 / 4.43 4.15 / 4.03 3.94 / 3.83

4 5 66 8 9

50 62.5 70130 162.5 182

daikin whitepainted galvanised steel

1~, 50Hz, 220-240V / 3~, 50Hz, 380-415V1,345 1,345 1,345900 900 900320 320 320

125/120 125/120 125/120Propeller

106 106 106102 105 105

hermetically sealed scroll compressordirect on line

-5.0 -5.0 -5.046 46 46-20 -20 -2015.5 15.5 15.566 67 6950 51 5352 53 55

R-410A4.0 4.0 4.0

expansion valve (electronic type)daphne FVC68D

1.5 1.5 1.59.52 (Flare) 9.52 (Flare) 9.52 (Flare)15.9 (Flare) 15.9 (Flare) 19.1 (Braze)

both liquid and gas pipes300 300 300

HPS, fan motor thermal protection, inverter overload protector, PC board fuse

RXYSQ4PA7V1B /RXYSQ4PA7Y1B RXYSQ5PA7V1B /RXYSQ5PA7Y1B RXYSQ6PA7V1B /RXYSQ6PA7Y1B

KRC19-26A6KJB111A

KHRQ22M29HKHRQ22M20T

KKPJ5F180

Cool/heat selectorFixing boxRefnet headerrRefnet jointCentral drain plug

Notes:Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, inlet water temperature: 30°C, equivalent refrigerant piping:7.5m, level difference: 0m.Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 7.5m,level difference: 0m.Sound power level is an absolute value that a sound source generates.Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please refer to sound leveldrawings.Sound values are measured in a semi-anechoic room.

EPC08-201.indb 15 18-03-2008 09:48:54

Page 16: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

16

850 mm

500mm

20-25-32-40-50

20-25-32-40-50-63-80-100-125

ROUND FLOW CEILING MOUNTED CASSETTE

ComfortModern style decoration panel in white (RAL9010)›360° air discharge ensures uniform air flow and temperature›distributionAir discharge from the corners avoids dead zones that may be›subject to temperature differencesComfortable horizontal air discharge ensures draughtfree operation›and prevents ceiling soiling23 different air flow patterns possible›Fresh air intake: up to 20%›

Flexible installation and easy maintenanceReduced installation height: 214mm for class 20-63›Easy visible drain check thanks to clear drain socket›Drain-up pump with 850 mm lift fitted as standard›

60°

Ceiling voidis 295 mm

360° Round Flow 4-Way Flow 3-Way Flow 2-Way Flow

EXAMPLES OF AIRFLOW PATTERNS

4-WAY BLOW CEILING MOUNTED CASSETTE (600MMX600MM)

ComfortModern style decoration panel in white (RAL9010)›Extremely quiet in operation›Excellent low draught characteristics. Since the flaps can move to›a 0° position, virtually no draught can be experiencedAny one of 5 different air flow patterns can be freely selected›between 0° and 60° and will then be maintained during theoperational cycle of the air conditioner

Flexible Installation and Easy MaintenanceThanks to the compact casing, it matches standard architectural›modules of 600x600mm, therefore ceiling tile cutting is no longernecessaryAir can be discharged in any of 4 directions›Possibility to shut 1 or 2 flaps for easy installation in corners›Since the switch box is located within the unit, it is easy to access›from below for maintenance without removing ceiling tilesDrain-up pump with 500mm lift fitted as standard›

EPC08-201.indb 16 18-03-2008 09:49:02

Page 17: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

17

20-32-40-63

20-25-32-40-50-63-80-125

2-WAY BLOW CEILING MOUNTED CASSETTE

ComfortQuiet in operation›Leaves maximum floor and wall space for furniture, decorations›and fittingsAutomatic air flow director ensures uniform air flow and›temperature distributionAnti-ceiling soiling technology›

FilterStandard long life filter›

Flexible Installation and Easy MaintenanceEasy installation in false ceilings of only 355mm›Drain-up pump with 600mm lift fitted as standard›Maintenance can be performed by simply removing›the front panelEasy to clean flat suction grille›Detachable swing flaps›

CEILING MOUNTED CORNER CASSETTEComfort

Equipped with special draught prevention and anti-ceiling soiling›technology

Automatic air flow director ensures uniform air flow and›temperature distributionAir flow by either downward air discharge, frontal discharge or a›combination of both

Flexible InstallationCompact dimensions, can easily be mounted in a narrow ceiling›void (only 220mm ceiling space required, 195 with panel spacer,available as accessory)

Drain-up pump with 500mm lift fitted as standard›

1Standard

Note: Standard setting when shipped.

2Draughtprevention

3Anti-ceilingsoiling technology

minimum ceilingheight is 355mm

600mm

CombinationFrontal discharge

Closed by the decoration panel

Downward discharge

Min. 195 mm

Panel spacer

20 mm 500 mm

EPC08-201_1-22.indd 17 21-04-2008 10:33:04

Page 18: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

18

20-25-32-40-50-63

20-25

SMALL CONCEALED CEILING UNIT

ComfortDesigned for hotel bedrooms›Blends unobtrusively with any interior décor: only the suction and›discharge grilles are visibleExtremely quiet in operation›

FilterAir suction filter fitted as standard›

Flexible InstallationCompact dimensions (230mm high & 652mm deep), can easily be›mounted in a ceiling voidThe air suction direction can be altered from rear to bottom›suctionFor easy mounting, the drain pan can be located to the left or the›right of the unit

SLIM CONCEALED CEILING UNIT

ComfortQuiet in operation›Blends unobtrusively with any interior décor›Leaves maximum floor and wall space for furniture, decorations›and fittings

200mm

Ceiling

Suction Chamber[Duct connection]

Air filter

Can be installed in both new and existing buildings›Medium external static pressure facilitates unit use with flexible›ducts of varying lengthsDrain-up pump with 750mm lift fitted as standard›

Flexible InstallationSlim design, can easily be mounted in a ceiling void of only›240mm

EPC08-201.indb 18 18-03-2008 09:49:18

Page 19: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

19

20-25-32-40-50-63-80-100-125

40-50-63-80-100-125

CONCEALED CEILING UNIT

ComfortHigh flexibility for a wide variety of applications›Quiet in operation›Blends unobtrusively with any interior décor›

FilterLong life filter fitted as standard›High efficiency filters (65% and 95%) available as accessory›

Flexible Installation and Easy MaintenanceHigh external static pressure facilitates unit use with flexible ducts›of varying lengthsWhen using suction panel, unit requires›only 350mm of ceiling spaceDrain-up pump with 625mm lift fitted as›standardThe air suction direction can be altered›from rear to bottom suctionThe switch box can be reached from the›side or from the bottom side of the unit foreasy servicing

CONCEALED CEILING UNIT

ComfortLeaves maximum floor and wall space for furniture, decorations›and fittings

Flexible InstallationCompact unit (a height of 300 mm), allows installation in narrow›ceiling voidsComplete range of models (FXMQ-PVE: 4.5 - 14 kW)›Built-in drain pump (standard for sizes 40 to 125) increases›reliability of the drain systemReduction of power consumption of 20%›(compared to FXMQ-MAVE series) through use of new DC FanPossibility to change ESP through wired remote control allows›optimisation of the supply air volume

625mm625mm

Min.350mm

EPC08-201_1-22.indd 19 04-04-2008 16:28:10

Page 20: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

20

1025

4055 70

100°

10° Cooling

70° Heating

32-63-100

20-25-32-40-50-63

WALL MOUNTED UNIT

ComfortCompact and stylish design blends unobtrusively in any interior›décorAutomatic air flow director ensures efficient air distribution via›louvers that close automatically when the unit is switched off5 different discharge angles can be programmed via the remote›controlDischarge angle automatically returns to its previous position on›restart (initial setting 10 degrees for cooling and 70 degrees forheating)

FilterMildew proof polystyrene filter and drain pan›

Flexible Installation and Easy MaintanceBoth horizontal flaps and front panel can easily be removed and›washedAll maintenance operations can be carried out from the front of›the unitDrain-up pump with 1,000mm lift available as accessory›Drain pipe can be fitted either to the left or right side of the unit›

SLIM CONCEALED CEILING UNIT

ComfortQuiet in operation›Leaves maximum floor and wall space for furniture, decorations›and fittingsEnhanced horizontal and vertical air circulation in all directions›thanks to an air flow pattern of 100°

FilterLong life filter fitted as standard›

Flexible Installation and Easy MaintanceCan be installed in both new and existing buildings›The ideal solution for installation without false ceilings›Drain-up pump with 600mm lift available as accessory›

Maintenance can be performed easily from below the unit›Bristle free flap makes cleaning easier›

1025

4055 70

Drain-up kit(built inside mainunit)

Drain-up kit(built inside mainunit)

10° Cooling

70° Heating

1,000mm

Height of drain-up

Drain-upkitIndoor unit

Drain-up kit

32-63-100

20-25-32-40-50-63

EPC08-201.indb 20 18-03-2008 09:49:33

Page 21: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

21

71-100-125

4-WAY BLOW CEILING SUSPENDED UNIT

ComfortGroup control with other VRV indoor units possible›Cool heat selection›Prevention of cold draught at hot start, defrost and oil return in›heatingAir can be discharged in any of 4 directions›Air can be discharged at 5 different angles between 0 and›60 degrees

Automatic air flow director ensures efficient air and temperature›distribution.Air flow distribution for ceiling heights up to 3.5m without loss of›capacity.

FilterAir filter, drain pan and heat exchanger fin are mildew proof and›anti-bacterial treated

Flexible InstallationIdeal for installation in new and existing buildings›5m maximum distance between FXUQ unit and junction box›Possibility to shut 1 or 2 flaps for easy installation in corners›Drain-up pump with 500mm lift fitted as standard›

EPC08-201.indb 21 18-03-2008 09:49:42

Page 22: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

22

Wall mounted Floor standing

20-25-32-40-50-63

20-25-32-40-50-63

FLOOR STANDING UNIT

ComfortIdeal for installation beneath a window›Compact dimensions (only 222mm deep and 600mm high)›All models are available with remote control›

FilterLong life filter fitted as standard›

Flexible Installation and Easy MaintanceRunning the pipes from connections at the back, enables the unit›to be wall mounted

CONCEALED FLOOR STANDING UNIT

ComfortIdeal for perimeter air conditioning›Ideal for installation below a window›All models are available with remote control›

FilterLong life filter fitted as standard›

Flexible Installation and Easy MaintanceOn site connection during installation is easier›The connecting port faces downward, eliminating the need to›attach auxiliary piping

Connectingport

Refrigerantpiping

On site connection during installation is easier›The fibreless discharge grille prevents condensation and staining›

EPC08-201.indb 22 18-03-2008 09:49:47

Page 23: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

23

R o u n d f l o w c e i l i n g m o u n t e d c a s s e t t e

20 25 32 40 50 63 80 100 125FXFQ-P

Capacity cooling kWheating kW

Power inputcooling kWheating kW

Dimensions (H x W x D) mmWeight unit kgCasing

Air Flow Ratecooling high / low m3 /minheating high / low m3 /min

Sound power (nominal) cooling dB(A)

Sound pressurecooling high / low dB(A)heating high / low dB(A)

Refrigerant namePower SupplyPiping Connections L / G / D diameter mmAir FilterDrain-up Height mm

Decoration Panel

modelcolour(H x W x D) mmweight kg

2.2 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.02.5 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0

0.053 0.063 0.083 0.095 0.120 0.173 0.2580.045 0.055 0.067 0.114 0.108 0.176 0.246

204 x 840 x 840 246 x 840 x 840 288 x 840 x84020.0 21.0 24.0 26.0

Galvanised steel12.5 / 9.0 13.5 / 9.0 15.5 / 10.0 16.5 / 11.0 23.5 / 14.5 26.5 / 17.0 33.0 / 20.012.5 / 9.0 13.5 / 9.0 15.0 / 9.5 17.5 / 12.0 23.5 / 14.5 28.0 / 17.5 33.0 / 20.0

49 50 51 52 55 58 6131 / 28 32 / 28 33 / 28 34 / 29 38 / 32 41 / 33 44 / 3431 / 28 32 / 28 33 / 28 36 / 30 38 / 32 42 / 34 44 / 34

R-410A1~ / 220-240V / 50Hz

6.35 / 12.7 / 32 6.4 / 12.7 / 32 9.5 / 15.9 / 32Resin net with mold resistance

750BYCQ140CW1

RAL901050x950x950

5.5

Notes:The sound pressure values are mentioned for a unit installed with rear suctionThe sound power level is an absolute value indicating the power wich a sound source generates.Nominal cooling capacities are based on: indoor temperature: 270CDB, 190CWB, outdoor temperature: 350CDB, equivalent refrigerant piping: 5m, level difference: 0m.Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.

ACCESSORIES

SPECIFICATIONS

Wired remote controlInfrared remote control cooling only

heat pumpDecoration panelReplacement long life filter (non-woven type)Fresh air intake kit (20 % fresh air intake) (chamber type)Air discharge outlet sealing member

BRC1D52BRC7F533FBRC7F532F

BYCQ140CW1KAFP551K160KDDQ5C140

KDBHQ55C140

FXFQ-P 20 25 32 40 50 63 80 125

EPC08-201.indb 23 18-03-2008 09:49:55

Page 24: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

24

4 - w a y b l o w c e i l i n g m o u n t e d c a s s e t t e ( 6 0 0 m m x 6 0 0 m m )

Notes:

Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.

2.2 2.8 3.6 4.5 5.62.5 3.2 4.0 5.0 6.373 73 76 89 11564 64 68 80 107

286 x 575 x 57518

galvanised steel plate9.0 / 7.0 9.0 / 7.0 9.5 / 7.5 11.0 / 8.0 14.0 / 10.030 / 25 30 / 25 32 / 26 36 / 28 41 / 33

47 47 49 53 58R-410A

ø6.4 / ø12.7resin net with mold resistant

5001~, 50Hz, 220-240V

55 x 700 x 7002.7

white (RAL 9010)

Cooling capacity kWHeating capacity kWNominal input cooling W

heating WDimensions (H x W x D) mmWeight kgCasingAir flow rate (H / L) m3 /minSound pressure level (H / L) (220V) dB(A)Sound power level dB(A)Refrigerant typePiping connections liquid / gas mmAir filterDrain-up height mmPower supply V1Decoration panel dimensions (H x W x D) mm

weight kgColour

20 25 32 40 50FXZQ-M8

20 25 32 40 50FXZQ-M8

BRC1D52BRC7E531BRC7E530BYFQ60B

KDBH44B60KDBQ44B60KAFQ441B60KDDQ44X60

Wired remote controlInfrared remote control cooling only

heat pumpDecoration panelSealing member of air discharge outletPanel spacerReplacement long life filterFresh air intake kit direct installation type

ACCESSORIES

SPECIFICATIONS

EPC08-201.indb 24 18-03-2008 09:50:07

Page 25: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

25

2 - w a y b l o w c e i l i n g m o u n t e d c a s s e t t e

Notes:

Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.

Cooling capacity kWHeating capacity kWNominal input cooling W

heating WDimensions (H x W x D) mmWeight kgCasingAir flow rate (H / L) m3 /minSound pressure level (H / L) dB(A)Sound power level dB(A)Refrigerant typePiping connections liquid / gas mmAir filterDrain-up height mmPower supply V3Decoration panel dimensions (H x W x D) mm

weight kgcolour

FXCQ-M8 20 25 32 40 50 63 80 125

2.2 2.8 3.6 4.5 5.6 7.1 9.0 14.02.5 3.2 4.0 5.0 6.3 8.0 10.0 16.077 92 92 130 130 161 209 25644 59 59 97 97 126 176 223

305 x 780 x 600 305 x 995 x 600 305 x 1,180 x 600 305 x 1,670 x 60026 31 32 35 47 48

galvanised steel plate7 / 5 9 / 6.5 9 / 6.5 12 / 9 12 / 9 16.5 / 13 26 / 21 33 / 25

33 / 28 35 / 29 35 / 29 35.5 / 30.5 35.5 / 30.5 38 / 33 40 / 35 45 / 3945 50 50 50 50 52 54 60

R-410Aø6.4 / ø12.7 ø9.5 / ø15.9

resin net with mold resistant600

1~, 50Hz, 230V53 x 1,030 x 680 53 x 1,245 x 680 53 x 1,430 x 680 53 x 1,920 x 680

8 8.5 9.5 12ivory white

Wired remote controlInfrared remote control cooling only

heat pumpDecoration panelHigh efficiency filter 65% *1High efficiency filter 90% *1Filter chamber for bottom suctionReplacement long life filter

BRC1D52BRC7C67BRC7C62

BYBC32G BYBC50G BYBC63G BYBC125GKAFJ532G36 KAFJ532G56 KAFJ532G80 KAFJ532G160KAFJ533G36 KAFJ533G56 KAFJ533G80 KAFJ533G160KDDFJ53G36 KDDFJ53G56 KDDFJ53G80 KDDFJ53G160KAFJ531G36 KAFJ531G56 KAFJ531G80 KAFJ531G160

20 25 32 40 50 63 80 125FXCQ-M8

Note:*1. Filter chamber is required when installing a high efficiency filter.

ACCESSORIES

SPECIFICATIONS

EPC08-201.indb 25 18-03-2008 09:50:14

Page 26: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

26

C e i l i n g m o u n t e d c o r n e r c a s s e t t e

Notes:

Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.*Data were not available at time of publication.

2.8 3.6 4.5 7.13.2 4.0 5.0 8.066 66 76 10546 46 56 85

215 x 1,110 x 710 215 x 1,310 x 71031 34

galvanised steel plate11 / 9 11 / 9 13 / 10 18 / 1538 / 33 38 / 33 40 / 34 42 / 37

* * * *R-410A

ø6.4 / ø12.7 ø9.5 / ø15.9resin net with mold resistant

5001~, 50Hz, 220-240V

70 x 1,240 x 800 70 x 1,440 x 8008.5 9.5

ivory white

Cooling capacity kWHeating capacity kWNominal input cooling W

heating WDimensions (H x W x D) mmWeight kgCasingAir flow rate (H / L) m3 /minSound pressure level (H / L) (220V) dB(A)Sound power level dB(A)Refrigerant typePiping connections liquid / gas mmAir filterDrain-up height mmPower supply VEDecoration panel dimensions (H x W x D) mm

weight kgcolour

FXKQ-MA 25 32 40 63

BRC1D52BRC4C63BRC4C61

BYK45F BYK71FKPBJ52F56 KPBJ52F80KAFJ521F56 KAFJ521F80K-HV7AW K-HV9AW

KDBJ52F56W KDBJ52F80WKFDJ52F56 KFDJ52F80

FXKQ-MA

Wired remote controlInfrared remote control cooling only

heat pumpDecoration panelPanel spacerReplacement long life filterAir discharge grilleAir discharge blind panelFlexible duct (with shutter)

25 32 40 63

ACCESSORIES

SPECIFICATIONS

EPC08-201.indb 26 18-03-2008 09:50:21

Page 27: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

27

S m a l l c o n c e a l e d c e i l i n g u n i t

Notes :

Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.

20 25

2.2 2.82.5 3.2

5050

230x502x65217

galvanised steel plate6.7/5.2 7.4/5.8

37/3250

R-410Aø6.4/ø12.7

resin net with mold resistant50Hz, 230V ,~1

FXDQ-M8

Cooling capacity kWHeating capacity kWNominal input cooling W

heating W(Dimensions (HxWxD mmWeight kgCasing(Air flow rate (H/L m3/min(Sound pressure level (H/L (dB(ASound power level (dB(ARefrigerant typePiping connections liquid/gas mmAir filterPower supply V3

20 25FXDQ-M8

Wired remote controlInfrared remote control cooling

heating

BRC1D52, BRC2C51, BRC3A61BRC4C64BRC4C62

ACCESSORIES

SPECIFICATIONS

EPC08-201.indb 27 18-03-2008 09:50:28

Page 28: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

28

S l i m c o n c e a l e d c e i l i n g u n i t

2.2 2.8 3.6 4.5 5.6 7.12.5 3.2 4.0 5.0 6.3 8.086 86 89 160 165 18167 67 70 70 152 168

200 x 700 x 620 200 x 900 x 620 200 x 1,100 x 62023 23 23 27 28 31

galvanised steel plate8.0 / 6.4 8.0 / 6.4 8.0 / 6.4 10.5 / 8.5 12.5 / 10.0 16.5 / 13.033 / 29 33 / 29 33 / 29 34 / 30 35 / 31 36 / 32

* * * * * *R-410A

750ø6.4 / ø12.7 ø9.5 / ø15.9

removable, washable, mildew proof1~, 50Hz, 220-240V

Cooling capacity kWHeating capacity kWNominal input cooling W

heating WDimensions (H x W x D) mmWeight kgCasingAir flow rate (H / L) m3 /minSound pressure level (H / L) dB(A)Sound power level dB(A)Refrigerant typeDrain-up height mmPiping connections liquid / gas mmAir filterPower supply VE

FXDQ20P FXDQ25P FXDQ32P FXDQ40NA FXDQ50NA FXDQ63NAFXDQ-P/NA

FXDQ-P/NA

BRC1D52BRC4C64BRC4C62

Wired remote controlInfrared remote control cooling only

heat pump

FXDQ20P FXDQ25P FXDQ32P FXDQ40NA FXDQ50NA FXDQ63NA

Notes:

Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.The sound pressure values are mentioned for a unit installed with rear suction.* Data were not available at time of publication.

ACCESSORIES

SPECIFICATIONS

EPC08-201.indb 28 18-03-2008 09:50:37

Page 29: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

29

C o n c e a l e d c e i l i n g u n i t

Cooling capacity kWHeating capacity kWNominal input cooling W

heating WDimensions (H x W x D) mmWeight kgCasingAir flow rate (H / L) m3 /minSound pressure level (H / L) dB(A)Sound power level dB(A)Refrigerant typePiping connections liquid / gas mmAir filterDrain-up height mmPower supply V3Decoration panel dimensions (H x W x D)

weight kgcolour

2.2 2.8 3.6 4.5 5.6 7.1 9.0 11.2 14.02.5 3.2 4.0 5.0 6.3 8.0 10.0 12.5 16.0110 110 114 127 143 189 234 242 32190 90 94 107 123 169 214 222 301

300 x 550 x 800 300 x 700 x 800 300 x 1,000 x 800 300 x 1,400 x 80030 30 30 30 31 41 51 51 52

galvanised steel plate9 / 6.5 9 / 6.5 9.5 / 7 11.5 / 9 15 / 11 21 / 15.5 27 / 20 28 / 20.5 38 / 2832 / 28 32 / 28 33 / 28 33 / 29 35 / 31 35 / 30 37 / 31 38 / 33 40 / 35

50 50 51 56 58 56 55 56 65R-410A

ø6.4 / ø12.7 ø9.5 / ø15.9resin net with mold resistant

6251~, 50Hz, 230V

55 x 650 x 500 55 x 800 x 500 55 x 1,100 x 500 55 x 1,500 x 5003 3.5 4.5 6.5

ivory white

20 25 32 40 50 63 80 100 125FXSQ-M8

Wired remote controlInfrared remote control cooling only

heat pumpDecoration panelService access panelHigh efficiency filter 65% *1High efficiency filter 90% *1Filter chamber for bottom suctionFilter chamber rear suctionAir suction canvasScreening door / blind boardAir discharge adapter for round duct

BRC1D52, BRC2C51, BRC3A61BRC4C64BRC4C62

BYBS32D BYBS45D BYB571D BYBS125DKTBJ25K36W KTBJ25K56W KTBJ25K80W KTBJ25K160WKAFJ252L36 KAFJ252L56 KAFJ252L80 KAFJ252L160KAFJ253L36 KAFJ253L56 KAFJ253L80 KAFJ253L160KAJ25L36D KAJ25L56D KAJ25L80D KAJ25L160DKAJ25L36B KAJ25L56B KAJ25L80B KAJ25L160BKSA-25K36 KSA-25K56 KSA-25K80 KSA-25K160KBBJ25K36 KBBJ25K56 KBBJ25K80 KBBJ25K160KDAJ25K36 KDAJ25K56 KDAJ25K71 KDAJ25K140

20 25 32 40 50 63 80 100 125FXSQ-M8

Notes:

Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.The sound pressure values are mentioned for a unit installed with rear suction.

Notes:*1. If installing a high efficiency filter in the unit, an assembly chamber for either bottom or rear suction is required.

ACCESSORIES

SPECIFICATIONS

EPC08-201.indb 29 18-03-2008 09:50:46

Page 30: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

30

C o n c e a l e d c e i l i n g u n i t

4.5 5.6 7.1 9.0 11.2 14.05.0 6.3 8.0 10.0 12.5 16.0

0.194(1) / 0.193(2) 0.215(1) / 0.214(2) 0.230(1) / 0.229(2) 0.298(1) / 0.297(2) 0.376(1) / 0.375(2) 0.461(1) / 0.460(2)0.182 0.203 0.218 0.286 0.364 0.449

300 x 700 x 700 300 x 1,000 x 700 300 x 1,400 x 70028 36 36 36 46 46

galvanised steel plate16/13/11 18/16.5/15 19.5/17.5/16 25/22.5/20 32/27/23 39/33/28note 3 note 3 note 3 note 3 note 3 note 3note 3 note 3 note 3 note 3 note 3 note 3

R-410Aø6.4 / ø12.7 ø9.5 / ø15.9

note 41~, 50Hz, 220-240V / 1~, 60Hz, 220V

Cooling capacity kWHeating capacity kWNominal input cooling W

heating WDimensions (H x W x D) mmWeight kgCasingAir flow rate (HH / H / L) m3 /minSound pressure level dB(A)Sound power level dB(A)Refrigerant typePiping connections liquid / gas mmAir filterPower supply VE

FXMQ-P 40 50 63 80 100 125

Notes:

Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.(1) 50Hz, 220-240V(2) 60Hz, 220V(3) Data were not available at time of publication.(4) The air filter is not standard accessory, but please mount it in the duct system at the suction side. Select its colorimetric method (gravity method) 50% or more.

40 50 63 80 100 125

BRC1D52BRC4C66BRC4C65

KAF372AA56 KAF372AA80 KAF372AA160KAF373AA56 KAF373AA80 KAF373AA160KDDF37AA56 KDDF37AA80 KDDF37AA160KAF371AA56 KAF371AA80 KAF371AA160

Wired remote controlInfrared remote control cooling only

heat pumpHigh efficiency filter 65%High efficiency filter 90%Filter chamberLonglife replacement filter

FXMQ-P

ACCESSORIES

SPECIFICATIONS

EPC08-201.indb 30 18-03-2008 09:50:54

Page 31: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

31

W a l l m o u n t e d u n i t

20 25 32 40 50 63FXAQ-MA

Cooling capacity kWcapacity kWNominal input cooling W

heating WDimensions (HxWxD) mmWeight kgColourAir flow rate (H / L) m3 /minSound pressure level (H / L) (220V) dB(A)Sound power level dB(A)Refrigerant typePiping connections liquid / gas mmAir filterPower supply VE

2.2 2.8 3.6 4.5 5.6 7.12.5 3.2 4.0 5.0 6.3 8.016 22 27 20 27 5024 27 32 20 32 60

290 x 795 x 230 290 x 1,050 x 23011 14

white7.5 / 4.5 8 / 5 9 / 5.5 12 / 9 15 / 12 19 / 1435 / 29 36 / 29 37 / 29 39 / 34 42 / 36 46 / 39

* * * * * *R-410A

ø6.4 / ø12.7 ø9.5 / ø15.9resin net washable

1~, 50Hz, 220-240V

Notes:

Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.*Data were not available at time of publication.

20 25 32 40 50 63FXAQ-MA

Wired remote controlInfrared remote control cooling only

heat pumpDrain pump kit

BRC1D52BRC7E619BRC7E618

K-KDU572DVE

ACCESSORIES

SPECIFICATIONS

EPC08-201.indb 31 18-03-2008 09:51:03

Page 32: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

32

C e i l i n g s u s p e n d e d u n i t

32 63 100FXHQ-MA

Notes:

32 63 100FXHQ-MA

ACCESSORIES

SPECIFICATIONS

EPC08-201_23-52.indd 32 04-04-2008 16:20:39

Page 33: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

33

4 - w a y b l o w c e i l i n g s u s p e n d e d u n i t

71 100 125FXUQ-MA

8.0 11.2 14.09.0 12.5 14.0180 289 289160 269 269

165 x 895 x 895 230 x 895 x 895 230 x 895 x 89525 31 31

white19 / 14 29 / 21 32 / 2340 / 35 43 / 38 44 / 39

56 59 60R-410A

ø9.5 / ø15.9 ø9.5 / ø15.9 ø9.5 / ø15.9resin net with mold resistant

1~, 50Hz, 230VBEVQ71MA BEVQ100MA BEVQ125MA

Cooling capacity kWHeating capacity kWNominal input cooling W

heating WDimensions (HxWxD) mmWeight kgColourAir flow rate (H / L)Sound pressure level (H / L) (220V) dB(A)Sound power level (H) dB(A)Refrigerant typePiping connections liquid / gas mmAir filterPower supply V1Combination with junction box

Notes:

Capacities are net including a deduction for cooling (an addition for heating) for indoor fan motor heat.

71 100 125FXUQ-MA

BRC1D52BRC7C529BRC7C528

KDBHJ49F80 KDBHJ49F140KDBTJ49F80 KDBTJ49F140KDGJ49F80 KDGJ49F140

KAFJ495F140KHFP49M63 KHFP49M140

Wired remote controlInfrared remote control cooling only

heat pumpSealing member of air discharge outletAir discharge decoration panelVertical flap kitReplacement long life filterL-type connection piping kit

JUNCTION BOX FOR CONNECTION TO VRV

71 100 125BEVQ-MA

100x350x225x 3.0 3.5

galvanised steel plate1~, 50Hz, 220-240V

Dimensions H x W x D mmWeight kgCasingPower supply VE

BEVQ-MA

ACCESSORIES

SPECIFICATIONS

EPC08-201.indb 33 18-03-2008 09:51:22

Page 34: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

34

F l o o r s t a n d i n g u n i t

Notes:

Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.*Data were not available at time of publication.

2.2 2.8 3.6 4.5 5.6 7.12.5 3.2 4.0 5.0 6.3 8.049 49 90 90 110 11049 49 90 90 110 110

600 x 1,000 x 222 600 x 1,140 x 222 600 x 1,420 x 22225 30 36

ivory white7/6 7/6 8/6 11/8.5 14/11 16/12

35/32 35/32 35/32 38/33 39/34 40/35* * * * * *

R-410Aø6.4/ø12.7 ø9.5/ø15.9

resin net with mold resistant1~, 50Hz, 220-240V

Cooling capacity kWHeating capacity kWNominal input cooling W

heating WDimensions (H x W x D) mmWeight kgColourAir flow rate (H/L) m3 /minSound pressure level (H/L) (220V) dB(A)Sound power level dB(A)Refrigerant typePiping connections liquid/gas mmAir filterPower supply VE

ACCESSORIES

SPECIFICATIONS

20 25 32 40 50 63FXLQ-MA

FXLQ-MA

BRC1D52, BRC2C51, BRC3A61BRC4C64BRC4C62

KAFJ361K28 KAFJ361K45 KAFJ361K71

Wired remote controlInfrared remote control cooling only

heat pumpLong life replacement filter

20 25 32 40 50 63

EPC08-201.indb 34 18-03-2008 09:51:28

Page 35: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

35

C o n c e a l e d f l o o r s t a n d i n g u n i t

Notes:

20 25 32 40 50 63FXNQ-MA

20 25 32 40 50 63FXNQ-MA

ACCESSORIES

SPECIFICATIONS

EPC08-201_23-52.indd 35 16-04-2008 09:35:42

Page 36: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

36

The Daikin heat recovery ventilation system modulates thetemperature and humidity of incoming fresh air to matchindoor conditions. A balance is thus achieved betweenindoor and outdoor ambients, enabling the cooling orheating load placed on the air conditioning system tobe reduced significantlyHRV units can be controlledindividually or integral with the air conditioning systemDaikin VRV® or Sky Air series)

9 models to choose from›Compact, energy saving ventilation›Specially developed heat exchange element with›HEP (High Efficiency Paper)Easy integration into the VRV› ® systemConnectable to current Daikin control systems:›

Total heatexchangedfoul air

Clean outdoor air

Total heatexchangedclean airFoul indoor air

(1) Sound pressure level is measured in heat exchange mode.

VAM150FA VAM250FA VAM350FA VAM500FA VAM650FA VAM800FA VAM1000FA VAM1500FA VAM2000FA150 250 350 500 650 800 1,000 1,500 2,000

27/28.5 28/29 32/34 33/34.5 34.5/35.5 36/37 36/37 39.5/41.5 40/42.569 64 98 98 93 137 157 137 13774 72 75 74 74 74 75 75 7558 58 61 58 58 60 61 61 6164 64 65 62 63 65 66 66 66269 269 285 285 348 348 348 710 710760 760 812 812 988 988 988 1,498 1,498509 509 800 800 852 852 1,140 852 1,14024 24 33 33 48 48 61 132 158

Ø 100 Ø 150 Ø 150 Ø 200 Ø 200 Ø 250 Ø 250 Ø 350 Ø 3501~, 50Hz, 220-240V

VAM-FA

VENTILATIONAir flow rate m3/hSound pressure level (max.) (1) dBAExternal static pressure (max.) PaTemperature exchange efficiency %Enthalpy exchange efficiency heating %

cooling %Dimensions H mm

W mmD mm

Weight kgDuct diameter mmPower supply VE

EPC08-201.indb 36 18-03-2008 09:51:54

Page 37: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

37

VKM50GAM VKM80GAM VKM100GAM4.71 7.46 9.125.58 8.79 10.69

500 - 500 - 440 750 - 750 - 640 950 - 950 - 82037 - 35.5 - 32 38.5 - 36 - 33 39 - 37 - 3438 - 36 - 34 40 - 37.5 - 35.5 40 - 38 - 35.5

160 - 120 - 100 140 - 90 - 70 110 - 70 - 6076 - 76 - 77.5 78 - 78 - 79 74 - 74 - 76.564 - 64 - 67 66 - 66 - 68 62 - 62 - 6667 - 67- 69 71 - 71 - 73 65 - 65 -69

natural evaporating humdifier2.70 4.00 5.40387 387 387

1,764 1,764 1,764832 1,214 1,214102 120 125

1~, 220-240V, 50Hz

VENTILATION, DX COIL & HUMIDIFIERFresh air conditioning load cooling kW

heating kWAir flow rate ultra high - high - low m3/hSound pressure level - 220V ultra high - high - low dBASound pressure level - 240V ultra high - high - low dBAStatic pressure ultra high - high - low PaTemperature exchange efficiency ultra high - high - low %Enthalpy exchange efficiency - cooling ultra high - high - low %Enthalpy exchange efficiency - heating ultra high - high - low %Humidifier typeHumidification capacity kg/hDimensions height mm

width mmdepth mm

Weight kgPower supply V1

VKM-GAM

VKM-GA

VKM50GA VKM80GA VKM100GA4.71 7.46 9.125.58 8.79 10.69

500 - 500 - 440 750 - 750 - 640 950 - 950 - 82038 - 36 - 33.5 40 - 37.5 - 34.5 40 - 38 - 3539 - 37 - 35.5 41.5 - 39 - 37 41 - 39 - 36.5

180 - 150 - 110 170 - 120 - 80 150 - 100 - 7076 - 76 - 77.5 78 - 78 - 79 74 - 74 - 76.564 - 64 - 67 66 - 66 - 68 62 - 62 - 6667 - 67- 69 71 - 71 - 73 65 - 65 -69

387 387 3871,764 1,764 1,764832 1,214 1,21496 109 114

1~, 220-240V, 50Hz

VENTILATION & DX COILFresh air conditioning load cooling kW

heating kWAir flow rate ultra high - high - low m3/hSound pressure level - 220V ultra high - high - low dBASound pressure level - 240V ultra high - high - low dBAStatic pressure ultra high - high - low PaTemperature exchange efficiency ultra high - high - low %Enthalpy exchange efficiency - cooling ultra high - high - low %Enthalpy exchange efficiency - heating ultra high - high - low %Dimensions height mm

width mmdepth mm

Weight kgPower supply V1

Heat purge (economiser): heat accumulated indoors›is discharged at nightIntegration of humidification and air conditioning›into HRV unitIncreased static pressure thanks to improved fan›performanceIndividual control via HRV remote control›Connectable to current Daikin control systems:›

EPC08-201.indb 37 18-03-2008 09:51:58

Page 38: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

38

Daikin has developed a new user friendly, software tool that allowsrapid VRV® selection and provides a professional result in the7 following steps:

Select indoor units1.Connect outdoor units to indoor units2.Automatic receipt of piping diagram with joints3.Automatic receipt of wiring diagram4.Connect appropriate centralised control systems5.Visualise result in Microsoft Word, Microsoft Excel and AutoCAD6. ®

Save project7.

Using VRV® Xpress enables VRV® selection to be achieved in a simple,complete and professional manner.

Windows95®, Windows98®, WindowsNT®, Windows2000®, WindowsXP® and WindowsVista®

are registered trademarks of Microsoft corporation.

EPC08-201_23-52.indd 38 21-04-2008 10:34:27

Page 39: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

39

FEATURES:›

®

Expert mode:1.

Quick mode:2.

Drawing mode:3.

A simple to use, Daikin computerised selection programme, designed®, Windows 98®, WindowsNT®, Windows

®, Windows XP® ® systems, enables consulting

® air conditioning systems to be

®, Windows98®, WindowsNT® ®, WindowsXP® and®

EPC08-201_23-52.indd 39 04-04-2008 16:20:47

Page 40: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

40

INFRARED REMOTE CONTROL›

Operation buttons: ON/OFF, timer mode start / stop, timer modeon /off, programme time, temperature setting, air flow direction (FXHQ,FXFQ, FXCQ and FXAQ models only), operating mode, fan speed control,filter sign reset, inspection / test indication

Display: Operating mode, battery change, set temperature, air flowdirection (FXHQ, FXFQ, FXCQ and FXAQ models only), programmed time,inspection / test operation, fan speed

SIMPLIFIED REMOTE CONTROL›

Simple, compact and easy to operate unit, suitable for use in hotelbedrooms

Operation buttons: ON/OFF, operating mode selection, fan speedcontrol, temperature setting

Display: Cool /heat changeover control, Heat Recovery Ventilation (HRV) inoperation, set temperature, operating mode, centralised control indication,fan speed, defrost /hot start, malfunction adjustment, operating modeselection, fan speed control, filter sign reset, inspection test /operation

SIMPLIFIED BUILT-IN REMOTE CONTROL›FOR HOTEL APPLICATIONS

Compact, user friendly unit, ideal for use in hotel bedrooms

Operation buttons: ON/OFF, fan speed control, temperature setting

Display: Heat Recovery Ventilation (HRV) in operation, set temperature,operating mode, centralised control indication, fan speed, defrost /hotstart, malfunction

EPC08-201.indb 40 18-03-2008 09:52:12

Page 41: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

41

WIRED REMOTE CONTROL›

Limit operation (min/max): room temperature is controlled within›adjustable upper and lower limits. Limit operation can be activatedmanually or by schedule timerReal time clock: indicates real time and day›Schedule timer:›- It is possible to programme a weekly schedule timer- It is possible to programme the remote control for each day of

the week.Five day actions can be set as follows:· Set point: unit is switched ON and normal operation is

maintained· OFF: unit is switched OFF· Limits: unit is switched ON and min /max control (cf. limit

operation for more details)Home leave (frost protection): during occupants’ absence, the›indoor temperature can be maintained at a certain level. Thisfunction can also switch the unit ON/OFFDifferent levels of disabled buttons can be selected as follows:›- Level 1: all buttons are accessible- Level 2: all buttons are disabled except for: ON / OFF, set

temperature up /down, fan speed, cooling /heating mode,enable /disable schedule timer, air flow direction adjustmentbutton

- Level 3: all buttons are disabled except for: ON/OFF, settemperature up /down, fan speed

User friendly HRV function, thanks to the introduction of a button›for ventilation mode and fan speedConstantly monitoring of the system for malfunctions in a total of›80 componentsImmediate display of fault location and condition›Reduction of maintenance time and costs›

Operation buttons: ON /OFF, timer mode start / stop, timer on /off,programmed time, temperature setting, air flow direction adjustment,operating mode selection, fan speed control, filter sign reset, inspectiontest /operation

Display: Operating mode, Heat Recovery Ventilation (HRV) in operation,cool / heat changeover control, centralised control indication, groupcontrol indication, set temperature, air flow direction, programmedtime, inspection / test operation, fan speed, clean air filter, defrost /hotstart, malfunction

EPC08-201.indb 41 18-03-2008 09:52:13

Page 42: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

42

UNIFIED ON/OFF CONTROL›

units›

2 remote controls in separate locations can be used››

Centralised control indication››

CENTRALISED REMOTE CONTROL›

›can be controlled

locationsZone control›

›››››

SCHEDULE TIMER›

››››

EPC08-201_23-52.indd 42 04-04-2008 16:20:47

Page 43: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

Modem

43

The ideal solution forcontrol and managementup to 2,000 indoor units

APPLICATION AREAA small commercial area of less than›40 indoor units.Critical applications for centralized monitoring.›

SYSTEM LAYOUTAllows monitoring and control of up to up to 50›stores or sites and 2,000 indoor units with justone modem and phone line.Automates daily air conditioningoperation inorder›to free users from the hassle of air conditioningoperation /management.The daily schedule setting allows automatic›operation afterward.Automates alarm (report messages) for any›malfunctions /errors. Immediate report of anyindoor unit breakdown to the servicing company.Automatic report of breakdown/ malfunction›information.Minimizes the inconvenience of not having air›conditioning via rapid messages

FUNCTIONSSchedule setup (Daily schedule)›- Start / stopA/C malfunction report›- Send message to monitoring systemManual operation›- Start / Stop, set temperature, operation mode,

fan speedStatus monitoring›- Start / Stop, set temperature,- Operation mode, room temperature, operation

time, error code

Modem

Public phoneline

PC for monitoring

Malfunction

DS-NETadapter

Max. of 10 DS-NETadapters

RS4

85R

S232

C

P1 - P2 F1 - F2

P1 - P2 F1 - F2

EPC08-201.indb 43 18-03-2008 09:52:25

Page 44: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

44

DIII-NET

Allows detailed and easy monitoring and operation of VRV® systems (max. 2 x 64 control groups)

LANGUAGESEnglish, French, German, Italian, Spanish

SYSTEM LAYOUTUp to 2x64 indoor units can be controlled›Onboard Ethernet port (web browser & e-mail)›Digital i / o contacts (option)›Touch panel (full colour LCD via icon display)›

MANAGEMENTWeb application & internet compatibility›- Monitoring & control according to user- Remote monitoring & control of more than one

building- Remote monitoring & control of more than one

building via internetPower Proportional Distribution (option)›PPD data is available on the internet›Easy management of electricity consumption›Enhanced history function›

CONTROLIndividual control (set point, start / stop, fan speed)›(max. 2x64 indoor units /groups)Schedule control (8 schedules, 17 patterns)›Flexible grouping in zones›Yearly schedule›Fire emergency stop control›Interlocking control›Increased HRV monitoring and control function›Automatic cooling /heating changeover›Quick selection and full control›Simple navigation›Heating optimization›Temperature limit›Password security: 3 levels›(general, administration & service)

CSV output of PPD(option) result

Public line

Air ConditioningNetwork ServiceSystem

OnboardEthernet

port

PCMCIAflash

memory

Onboard

modem

third party controller(domotics, BMS, etc.)

Ethernet

Links to the wattmeter whenusing the PPD (option) function

Remote monitoring /controlvia internet, e-mailPPD data is available oninternet

Pi-port

Malfunction

EPC08-201.indb 44 18-03-2008 09:52:34

Page 45: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

45

MONITORINGVisualisation via Graphical User Interface (GUI)

Icon colour display change function›Indoor units operation mode›Error messages via e-mail & mobile phone (option)›Indication filter replacement›Multi PC›

COST PERFORMANCELabour saving›Easy installation›Compact design: limited installation space›Overall energy saving›

OPEN INTERFACECommunication to any third party controller›(domotics, BMS, etc.) is possible via open interface.

CONNECTABLE TOVRV› ®

HRV›Sky Air (via interface adapter)›Split (via interface adapter)›

Fire alarm

Forced OFF contact input

DIII-NET

Indoor units

Controls drainpump, lighting etc.

Monitoring of roomenter/exit sign

HRV

DIO unit

RS-232C

DIII-NET PLUSadapter

DIII-NET Allows monitoring/controlof up to 64 units (groups)

HRVIndoor unit

DI unit

EPC08-201.indb 45 18-03-2008 09:52:49

Page 46: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

~

~

46

The ideal solution for control and managementof maximum 1,024 VRV® indoor units

SYSTEM LAYOUTUp to 1,024 indoor units can be controlled›(by 4 iPUs)Ethernet TCPIP /10 base / T communication›Integrated digital contacts on the Intelligent›Processing Unit (iPU)- 19 general input ports- 2 digital outputsStand alone operation of the iPU for minimum›48 hoursCompatible with UPS shutdown software›

Web Access

Sub PC

ETH

ERN

ET

Intranet/Internet Web Access

Malfunction reportby E-Mail

Dio unitPower supply facility

Daikin CentralAir Conditioning System

VRV® SystemLocal

monitoring& control

DMS502A51BACnet Gateway(monitoring only)

Air ConditioningNetwork Service System(Optional Maintenance Service)

ElectricityMeasurement

(Via Internet)

Ai unit

HRV

DAM602B51/52

MANAGEMENTWeb access function (option)›Power Proportional Distribution (option)›Operational history management (start/stop,›malfunction, operation hours)Generation of reports (graphics & tables)›(daily, weekly, monthly)Peak load shedding›Advanced tenant management›Sliding temperature›Eco mode (option)›

CONTROLIndividual control (setpoint, start / stop, fan speed)›(max. 1,024 indoor units)Group control (100 groups)›Schedule control (128 programs)›Fire emergency stop control (32 programs)›Interlocking control›Setpoint limitation›Automatic cooling heating changeover›Power failure / release control›Temperature limit (automatic start)›Timer extension›

MONITORINGVisualisation via a Graphical User Interface (GUI)›featuring free layoutOperation mode of indoor & outdoor units›Fault indication›Indication filter replacement›Setpoint indication›Operation time monitoring›Multi PC›On-line help›

Fire alarm

DIII-NET

DIII-NET

DIII-NET

DIII-N

ET

EPC08-201_23-52.indd 46 21-04-2008 10:34:39

Page 47: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

47

Lonworks Networks CompatibleGateway

Interface for connection to›LonWorks® networksCommunication via Lon protocol›(twisted pair wire)64 units connectable per DMS-IF›Unlimited site size›Quick and easy installation›

Integrated control system connecting VRV® system with BMS system.

PPD data is available on BMS-system›Interface for BMS system›Communication via BACnet protocol›(connection via Ethernet)

256 units connectable per BACnet gateway›Unlimited site size›Easy and fast installation›

BUILDINGCONTROLNETWORK

LON BMS

FirealarmSystem

Security

adapterLonTalk

LonTalk

LonPoint LonPoint

(ETH

ERN

ET(T

CP/

IP

adapter

DMS504B51

Local Control

DIII- NET

VRV®

Outdoor unit

HRV

Remote Control

DAIKIN A/C INFRASTRUCTURE

DAIKIN A/C INFRASTRUCTURE

BMS

BA

CN

ET/E

THER

NET

Fire alarm Security

DMS502A51

Local ControlDAM602B51 /52(Intelligent Manager)

Control and monitoring

DIII- NET

VRV®

Outdoor unit

HRV

Remote Control

Power supply facility

Pump Lighting Elevator

BUILDINGCONTROLNETWORK

EPC08-201.indb 47 18-03-2008 09:53:17

Page 48: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

48

INDIVIDUAL CONTROL SYSTEMS

BRC1D52BRC7F533 BRC7E531 BRC7C67 BRC4C63 BRC4C64 BRC4C64 BRC4C64 BRC4C66 BRC7C529 BRC7E66 BRC7E619 BRC4C64 BRC4C64BRC7F532 BRC7E530 BRC7C62 BRC4C61 BRC4C62 BRC4C62 BRC4C62 BRC4C65 BRC7C528 BRC7E63 BRC7E618 BRC4C62 BRC4C62

- - - - BRC2C51 BRC2C51 BRC2C51 BRC2C51 - - - BRC2C51 BRC2C51- - - - BRC3A61 BRC3A61 BRC3A61 BRC3A61 - - - BRC3A61 BRC3A61

Wired remote controlInfrared remote control cooling only

heat pumpSimplified remote controlSimplified remote control for hotel use

CENTRALISED CONTROL SYSTEMS

DCS302C51DCS301B51DST301B51

Centralised remote controlUnified ON/OFF controlSchedule timer

DESCRIPTION

OTHERS

DESCRIPTION

Wiring adapterWiring adapter (hour meter)Wiring adapter for electrical appendices (1)Wiring adapter for electrical appendices (2)Remote sensorInstallation box for adapter PCBElectrical box with earth terminal (3 blocks)Electrical box with earth terminal (2 blocks)Noise filter (for electromagnetic interface only)External control adapterInterface adapter for Sky Air seriesConnector for forced on/forced off

- KRP1B57*1 - KRP1B61 KRP1B61 KRP1B56 - KRP1B61 KRP4A53 KRP1B3 - KRP1B61 KRP1B61EKRP1C11*1 - EKRP1B2 - EKRP1B2*2 - EKRP1B2 - - - - -KRP2A526*1 KRP2A526*1 KRP2A516*1 KRP2A61 KRP2A516 KRP2A53 KRP2A516 KRP2A61 KRP2A62* KRP2A51 KRP2A51 KRP2A51KRP4AA53*1 KRP4A536*1 KRP4A516*1 KRP4A51 KRP4A516 KRP4A54 KRP4A516 KRP4A51 KRP4A52* KRP4A51 KRP4A51 KRP4A51KRCS01-4 KRCS01-1KRP1H98 KRP1BA101 KRP1B96*3/4 - - KRP1BA101 - KRP1B97 KRP1C93*3 KRP4A93*3/4 - -

- KJB311AKJB212AA KJB212A

- KEK26-1A- DTA104A52 DTA104A51*1 DTA104A61 DTA104A51 DTA104A53 DTA104A51 DTA104A61 DTA104A62 DTA104A51 DTA104A61 DTA104A61- - - - - - - - DTA102A52 - - - -- - - - - - - - EKRORO - - - -

Notes:*1: Installation box is required*2: Fixing box is KRP1A90*3: Up to 2 adapters can be fixed per installation box*4: Only 1 installation box can be installed per indoor unit

DS-net adapterSoftware

DTA113B51 4 units can be connected per adapter, 40 units when 10 adapters are connectedDPC001B1-B51 Monitoring panel software

DCS601C51 2x64 units can be connectedDCS002C51 Power Proportional Distribution (PPD) softwareDCS004A51 E-mail / Web softwareDCS601A52 DIII NET-Plus adapterKJB411A For wall mounted installation1264009 Spare part n° of Touch-Pen for Intelligent Touch Controller

KRP928A2S For connection to Split unitsDTA102A52 For connection to R-22 / R-407C Sky Air unitsDTA112B51 For connection to R-410A Sky Air unitsDEC101A51 Input contacts: 16 pointsDEC102A51 Input contacts: 8 points; output contacts: 4 points

Intelligent Touch ControllerSoftware

HardwareInstallation boxTouch-PenInterface adapters

Digital inputDigital input/output

DESCRIPTION

DESCRIPTION

REFERENCE COMMENTS

REFERENCE COMMENTS

DESCRIPTION FXFQ FXZQ FXCQ FXKQ FXDQ FXDQ-N FXSQ FXMQ FXUQ FXHQ FXAQ FXLQ FXNQ

FXFQ FXZQ FXCQ FXKQ FXDQ FXDQ-N FXSQ FXMQ FXUQ FXHQ FXAQ FXLQ FXNQ

FXFQ FXZQ FXCQ FXKQ FXDQ FXDQ-N FXSQ FXMQ FXUQ FXHQ FXAQ FXLQ FXNQ

EPC08-201.indb 48 18-03-2008 09:53:19

Page 49: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

49

DAM602B51 256 indoor units per IPUDAM602B52 128 indoor units per IPU

IM3.XX Up to 1,024 indoor unitsKRP928A2S For connection to Split unitsDTA102A52 For connection to R-407C/R-22 Sky Air unitsDTA112B51 For connection to R-410A Sky Air units

DAM101A51 Outdoor temperature sensorDEC10151* Input contacts: 16 pointsDEC10251* Input contacts: 8 points; output contacts: 4 points

DAM002A51DAM003A51DAM004A51

Intelligent Processing unit

SoftwareInterface adapters

DIII AiDigital inputDigital input / outputPower Proportional DistributionECO ModeWeb Acces Function

DESCRIPTION REFERENCE COMMENTS

DMS502B51 64 units per GatewayDAM411B51 Extension of 3 x DIII lines (3 x 64) indoor unitsDAM412B51 For forced shutdownKRP928A2S For connection to Split unitsDTA102A52 For connection to R-407C/R-22 Sky Air unitsDTA112B51 For connection to R-410A Sky Air units

BACnet GatewayDIII boardDigital input/outputInterface adapters

DESCRIPTION REFERENCE COMMENTS

BMS: BUILDING MANAGEMENT SYSTEM

Conta

ct/a

nalog

signa

l

Parallel interface - Basic unitTemperature measurement unitsTemperature setting unitsUnification adapter for computerised controlWiring adapter for electrical appendices (1)

Wiring adapter for electrical appendices (2)External control adapter for outdoor unit

DIII-net expander adapter

Mounting kit

DPF201A51 enables ON/OFF command, operation and display of malfunction can be used in combination with up to 4 units.DPF201A52 enables temperature measurement output for 4 groups; 0~5VDC.»DPF201A53 enables temperature setting input for 16 groups; 0~5VDC.»DCS302A52 used for combining of air conditioning control computer and central remote controller (ON/OFF, display)KRP2A51 simultaneously controls air conditioning control computer and up to 64 groups of indoor units.KRP2A52

KRP4A51-53 to control the group of indoor units collectively, which are connected by the transmission wiring of remote controller.DTA104A51

cooling/heating mode change over, demand control and low noise control are available between the plural outdoor units.DTA104A52DTA109A51 a maximum of 10 outdoors or 128 indoors can be connected to 1 DTA109A51

a maximum of 8 DTA109A51 can be connected to DIII-netKRP4A92 for easy installation of the DTA109A51

DESCRIPTION REFERENCE COMMENTS

DMS504B51 Up to 64 units can be connected per DMS-IFKRP928A2S For connection to Split unitsDTA102A52 For connection to R-407C/R-22 Sky Air unitsDTA112B51 For connection to R-410A Sky Air units

LONWORKS® networks compatible GatewayInterface adapters

DESCRIPTION REFERENCE COMMENTS

EPC08-201.indb 49 18-03-2008 09:53:20

Page 50: NJN KQ KL= EKkangalov.com/files/1397328264_675.pdf · 2014. 4. 12. · NJN KQ KL= EK EPC08-201.indb 1 18-03-2008 09:47:20. 2 = F N A J G F E = F L 9 D 9 O 9 J = F = K K Air Conditioning

50