FLUXUS® F________
Non-Intrusive Liquid Flow Measurement
Industries:
Chemical
Petrochemical
Oil Exploration & Production
Pharmaceutical
Semiconductor
Food and Beverage
Water and Wastewater
Power Generation
Facilities Management _______________
External Measurement of Internal Flow
FLEXIMwhen measuring matters
2
FLUXUS® measures flow non-intrusively using ultrasonic technology. The ultrasonic transducers are simply clamped on to the outside of the pipe and are never in contact with the liquid – pipe work is not necessary.
Our non-intrusive clamp-on technology provides maximum flexibility and the sophisticated electronics of FLUXUS® ensure the highest possible accuracy and reliability. The measuring system, consisting of the transmitter, the trans-ducers and the PERMALOK mounting fixture, can be optimally configured to meet your individual requirements.
The FLUXUS® flowmeter series comprises a broad variety of transmitters and transducers: from basic models for standard applications up to robust mea-surement solutions for offshore use or for hazardous area metering locations.
Intelligent Signal Processing
FLUXUS® instruments feature an ex- ceptionally robust dual-μP technology core together with the latest digital signal processing. They produce sta- ble and reliable results even under the most difficult application conditions. The FLUXUS® measurement algo- rithms automatically adapt to varying application conditions. Its very high measurement rate of up to 1000 mea-surements per second allows for a real time statistical analysis. All this makes the FLUXUS® unsurpassed in perfor-mance and one of the most advanced ultrasonic flow meters available on the market today.
FLUXUS® is ...________
FLUXUS® F808 - FM Class I Div I Approved
Our Tradition is Innovation
Ever since its inception, FLEXIM has been among the pioneers in the field of ultrasonic flow measurement. Each FLUXUS® embodies the wealth of ex-pertise and the application experience of our engineers.FLEXIM rises to meet the challenges where others have already failed. Put FLEXIM’s experience and expertise to work for you. Submit your application to us and we will find the ideal solution!
Wav
eInj
ecto
r® e
xtre
me
tem
pera
ture
mea
sure
men
t sol
utio
n (-
300°
F to
750
°F a
nd b
eyon
d)
3
From 1/4 inch tubing to 20 feet penstocksFLEXIM’s non-intrusive ultrasonic tech-nology handles an unmatched range of applications. FLUXUS® offers accurate and reliable measurements from the smallest pipes (e.g. 1/4 inch tubing in paint finishing systems) up to very large pen-stocks (e.g. flow measure-ments in hydroelectric plants).
For virtually every liquid and pipe materialMeasurement is possible on just about every liquid medium and pipe material, regardless of sonic conductivity. Steel, iron or plastic pipes; sludge, sand, acids or tar: FLUXUS® is up to the task!
Up to 750 ° F and beyond
Standard transducers may be used for media temperatures up to 265 ° F, the temperature range of the high temp. versions extends this up to 390 ° F. The patented WaveInjector® system further extends the measurement range of FLEXIM’s standard transducers from cryogenic temperatures as low as -300 ° F up to 750 ° F and beyond.
... even in hazardous area locationsTransducers and transmitters are avail- able in FM certified versions.
Flexible.________
The advantages of the non-intrusive measurement are obvious: since the ultrasonic transducers are simply attached to the outside of the pipe, the measuring equipment is not subject to wear and tear by the media and does not cause pressure loss.
Measurements at maximum operating pressures can be carried out easily with no additional costs. No pipe work is required when setting up the measu-ring point and, as a result, the operation is not interrupted.
100% plant availability p Simple attachment of the PermaLok
transducer system on the outside of the pipe
p Installation is possible during normal ongoing operation without process downtime
100% resistant to media p No contact with media, therefore
no chemical attack p No need to use expensive special
materials
100% wear-free p No wear and tear by abrasive media p Long-term stable, maintenance-free
operation due to permanent coupling pads
100% leak-proof p No additional risk of leakage
by the measuring equipment
100% pressure-resistant p No pressure limit p Effortless measurement even at
maximum operating pressures p No extra charge for high
pressure ranges p Zero point stability and measure-
ment readings are not affected by static pressure changes
100% secure p No blockage of small bores or
impulse piping p Unaffected by pulsations,
vibrations, speed peaks, swirling or cross flows
100% robust p Resistant to pressure surges, solids
or bubbles in the medium p No more grease - solid couplant Pad
Non-intrusive.________
4
Perm
aRai
l mou
ntin
g so
lutio
n
Stai
nles
s Pe
rmaL
ok m
ount
ing
solu
tion
5
100% economical p No pressure loss, thus low
operating costs p Cost-effective installation p Installation without welding or other
mechanical work on the pipe p No extra charge for large
pipe diameters
100% progressive p Precise, hysteresis-free,
bi-directional flow measurement with large dynamic range (turndown)
p Long-term stability, drift-free measurement results
p High measuring rate p Quick response time p Measurement of even minute flows p High sensitivity to low flows
Expansion & Contraction of Non Metalic Pipes easily accommodated by FLEXIM‘s FlexSprings Mounting Design
6
“Plug & Play” calibrated transducersEach pair of transducers undergoes a rigorous calibration at the factory and is shipped with NIST traceable calibration documentation. All calibrati-on data (including the transducer identification and parameters) is stored in a transducer-resident non-volatile memory. It is automatically transferred to the transmitter upon connection. Consequently, programming errors are eliminated and there is never a need for zero adjustment or calibration.
Guaranteed to be user friendlyNo elaborate instructions are required to use FLUXUS®‘s intuitively structured menus. Pipe and material parameters are easily found in the internal liquid media and pipe materials database. Measurement is activated with just a few key strokes. Our explosion proof instruments can be operated without ha-ving to open the housing and without requiring any additional programming devices.
A “Straight-Shot” from the pipe to the PCFluxDiag connects FLUXUS® to any PC. This software package with a graphi-cal user interface takes care of the data exchange between the transmitter and the computer. With FluxDiag, you can readily transfer your measurement data from the flowmeter to a PC, analyze and visualize the measuring results and manage the data files directly or easily export them to an external data manage-ment program for analysis.
User-Friendly.________
7
* for measurement acc. to transit time difference principle, under reference conditions and at v > 0.15ft/s** reference uncertainty < 0.2 %
General Technical Data
Measuring principle: Transit time difference correlation principle
Quantities of measurement: Volume flow, mass flow, flow velocity, thermal energy flow (when temperature inputs are installed)
Flow velocity: 0.03 to 82 ft/s
Repeatability: 0.15% of reading ± 0.03 ft/s
Calibrated transducer accuracy:- with 5 point wet flow calibration (NIST traceable): - with field calibration**:
± 1 % of reading ± 0.03 ft/s± 0.5 % of reading ± 0.03 ft/s
Gaseous and solid content: < 10 %
Measuring principleThe Transit Time Difference Correlation Principle makes use of the fact that the time-of-flight of an ultrasonic signal is affected by the flow velocity of the carrier medium. Like a swimmer working his way across a flowing river, an ul-trasonic signal travels slower upstream than downstream. Our instruments work according to this transit-time prin-ciple: an ultrasonic pulse is sent downstream through the medium, another pulse is sent upstream. By measuring the transit time difference, the average flow velocity can be determined. The volume flow can then be calculated out of the flow velocity and the pipe’s dimensional parameters. The acoustic measuring method works without inertia and is independent of the flow direction. As a result, FLUXUS® measures the flow bidirectionally with excellent measurement rangeability.
8
The Transducer System
“Fit for the Purpose“ ConstructionAll FLEXIM clamp-on transducers are watertight and suitable for use in harsh industrial environments. The robust stainless steel construction and the rugged integrated stainless steel cables guarantee reliable measurement results over long periods of extensive use. Almost all transducer types are available for use in hazardous areas and IP68 / NEMA 6P submersible applications.
Robust transducer mounting fixturesFor permanent installation in industrial environments, three specific mounting options are available. All are construc-ted out of stainless steel and are especi-ally corrosion resistant. The transducer distance can be set easily and precisely. Maintenance requirements are elimina-ted due to permanent contact to the pipe wall with coupling pads. Even in the event of strong temperature fluctuations, a continuous, stable contact pressure between the transducers and the pipe is ensured, allowing for optimal signal transmission through the pipe wall.
PermaStrap: Direct Strap mounting affords the most economical mounting solution. Used with the coupling pads the simple strap band is an effective mounting solution.PermaRail Track: Designed to keep a constant pressure of the transducer on the pipe. Good selection for a range of applications like pipes with tempera-ture fluctuations, and high vibrations.PermaLok Track: Optimum protection for harsh environments. The rugged Stainless Steel enclosure fully gaske-ted protects the transducer from water, dirt and harsh elements that can create a need for maintenance.FLEXIM also offers a completely metal -free transducer and mounting fixture solution for the semiconductor industry measuring flow rates within flexible tu-bes in clean room environments.
Industry Hardened.________
9
General Technical Data of the Transducers
Operating temperature, standard transducers: -40 ° F to +265 ° F
Operating temperature, extended temperature transducers:
-20° F to +390 ° F
Operating temperature with WaveInjector®: from -300 ° F up to +750 ° F and beyond
Protection degree: IP65, IP67 or IP68 depending on type (EN 60529) NEMA 4, NEMA 4X, NEMA 6, NEMA 6P
Material: Stainless steel or PEEK with stainless steel protective cap (stainless steel SS316 optional)
Hazardous area classification: FM Class I, Div. 1 / 2 and ATEX (IECEx) Zone 1 & 2 types available (FMUS and FMC and GOST)
10
Unmatched in performance, FLEXIM‘s portable flow meters are the ideal tool for support in service and maintenance activities for the control and check of existing meters, their temporary replacement, or at measurement points not co-vered by permanent meters. The wide pipe diameter ran-ge of each transducer type is one of their greatest assets: two pairs of transducers sufficiently cover the most common pipe diameter ranges.
In addition, the optional thermal energy measurement capability makes it possible to carry out a complete analysis of thermal energy usage in any facility.
With their sturdy and rugged design, they are the measu-rement system of choice in harsh environment including hazardous areas.
Portable, quick and reliable.________
FLUXUS® F401 and F60X
Applications FLUXUS® F60X
Chemical industry p Flow measurement of any inorganic and organic
liquid media (incl. highly corrosive and toxic media) - even in hazardous areas (ATEX (IECEx) Zone 2, FM Class I, Div, 2 approved)
p Portable flow control at plant start-ups, inspection of facilities and process optimization
p Measurement of thermal energy quantities for energy efficiency audits
Oil & Gas p Flow measurement during exploration &
production p Measurement of hydrocarbon product flows
within terminals (storage and allocation) p Measurement within refinieries and petrochemical
industries (up to +750 °F in hazardous areas)
Power industry p Measurement of boiler feed water flows p Monitoring of cooling circuits
Applications FLUXUS® F401
The FLUXUS® F401 is FLEXIM‘s dedicated one channel flow meter for water applications and is designed for long term stable and accurate measurements in remote areas outdoors (transducers with IP68 / NEMA 6P protection degree).
Water and wastewater industry p Clean measurement process for
drinking water systems p Leak detection p Water loss balancing p Verification of sewage lift station
performance p Temporary monitoring of distribution
and collection systems p Verification of pump and valve
performance
FLUXUS® F401
11
F401 / F60X: The Portable All-Round Meters
Operating temperature: Transmitters: -14 ° F to +(120) 140° F Transducers F60X: -40 °F to +265 °F (-300 °F to 750°F) Transducers F401: - 40F to +210 °F
Protection degree F60X: Protection degree F401:
IP65 / NEMA 4 IP67 /NEMA 6
Hazardous Area Classification (F608):
ATEX (IECEx) Zone 2, FM Class I, Div. 2 (Transducers: ATEX (IECEx) Zone 1 and 2, FM Class I, Div. 2)
Battery life F60X: Battery life F401:
>17 hours >24 hours, with external battery >1 week
Inputs and outputs: F401:
Only Outputs: 1 x current, 1 x binary
Variants F60X Standard and Energy:
Inputs (Energy variant only): 2 x Pt 100/1000 Outputs: 2 x current, 2 x binary
Double Energy (only F601):
Inputs: 4 x Pt 100/1000; Outputs: 2 x current, 2 x binary
Multifunctional (only F601):
Inputs: 2 x Pt 100/1000, 2 x current; Outputs: 4 x current, 2 x binary
Facility management (HVAC) p Optimization of heating and
air conditioning systems in large building complexes
p Pump control, preventative maintenance and checks
p Optimization of energy efficiency p Detection of fouling processes in
heat exchangers p Short-term replacement of insert
energy meters in case of failures
Food & Beverage, Pharmaceutical and Semiconductor industry
p Non-invasive measurement of ultra pure fluids, even in PVC, PFA and glass pipes
FLUXUS® F601/F608
12
Applications FLUXUS® ADM 5X07
Municipial water supply p Flow measurement on small to
large diameter pipes p Consumption and distribution
analysis p Leakage analysis
Building automation p Hygienic, contact-free measurement at
water carrying pipes - even at very low flow velocities with no potential for leaks
Semiconductor industry p Non-invasive measurement of ultra pure
fluids, even in PVC, PFA and glass pipes (metal-free transducers and mounting fixture available)
Permanently installed, freely configurable.________
FLUXUS® ADM 5X07 and F70X
With the FLUXUS® ADM 5X07 and F70X series, FLEXIM offers ultrasonic clamp-on flowmeters for permanent measuring points. The F70X family is expressly designed towards metering applications in industrial environments, measuring virtually any liquid media in any environment and temperature range - even in harsh corrosive atmospheres from as low as -310 °F up to +750 °F and beyond. Additionally, as an Energy version it can also measure thermal energy / BTU quantities in heating / chiller plants and heat exchangers within the real estate sector or any other industry.
The ADM 5X07 meter is specifically engineered for the measure- ment of water flow rates only and thus the ideal measurement solution for water supply networks, the building automation sector and manufacturing industries.
FLUXUS® ADM 5107
FLUXUS® F704.316SE
Applications FLUXUS® F70X
Chemical industry p Measurement of corrosive or toxic media
such as acids and caustics p Measurement of non-conductive media,
e.g. hydrocarbon based products p Measurement of highly viscous media p Measurement of media containing
fibers or solid particles p Measurement of liquid media at
extreme temperatures (from -310 °F to +750° F and beyond)
p Measurement on any pipe - even PVC or FRP pipes and tubes
Oil and Gas p Measurement of all hydrocarbon
liquids (up to +750°F) p Measurement on high pressure
systems p Measurement of highly viscose and
abrasive media p Measurement of injection media
and additives
13
ADM 5X07 and F70X: The Multi-Functional Meters
Operating temperature: Transmitters: Transducers:
-4 ° F (-40 ° F ) to +140 ° F from -300 ° F to +750 ° F and beyond
Flow channels: 1 or 2
Protection degree: F70X: NEMA 4X (F704.316SE: FM Class I, Div. 2 approved) ADM 5X07: NEMA 4X
Outputs: A variety of combinations are available from the following: current (0/4 mA ... 20 mA), voltage, frequency, pulse, alarm
Inputs: (ADM 5X07: none)
Maximum 4. Available are: Temperature (Pt 100/1000 4-wire), current, voltage
Communication: HART, Modbus, BACnet
Petrochemical industry p Measurement of basic materials
as well as intermediate and final products
p Measurement at high temperatures, for example tar, bitumen, quench liquids
Power plants p Measurements of cooling water,
boiler feed water, condensate and heat circuits
Water and wastewater industry p Flow measurement on large diameter
pipes (influent, effluent, sludges) p Consumption and distribution analysis
measurements p Measurement of underground
or underwater pipes (transducers are buried)
p Chemical media flows (small pipe and low flows)
FLUXUS® F704
Applications Petrochemical industry
p Measurement of basic materials as well as intermediate and final products
p Measurement of crude oil during sampling for quality analysis
p Measurement at high temperatures (+750 °F), e.g. ADU / VDU outlets, overflash and sump measurement
p Measurement of heavy gasoil (HGO)/heavy vacuum gasoil (HVGO)
p Measurement at cracker feeders p Monitoring the flow of heat
transfer oil
Chemical industry p Flow measurement in hazardous areas p Flow measurement of inorganic
and organic media (even highly corrosive and toxic media)
Experts for Hazardous Areas.________
FLUXUS® F704.316SE and F808
With the FLUXUS® F704.316SE and F808 FLEXIM offers two FM approved flow meters for usage in hazardous areas.
The stainless steel (316L / 1.4404) enclosed F704.316SE flow meter is FM Class I, Div.2 approved, where the FLUXUS® F808, with its hermetically sealed connections and electronics compartment, is FM Class I, Div.1 approved.
Both meters are highly corrosion resistant and thus also ideally suited for applications offshore.
As product variant FLUXUS® HPI, the individual hydrocarbon product flo-wing in the pipe can also clearly be identified. This is especially helpful in storage terminals when different batches have to be distinguished, or when water / oil cuts have to be determined in tank dewatering applications.
FLUXUS® F704.316SE
FLUXUS® F808
14
15
Applications Petrochemical industry
p Measurement of basic materials as well as intermediate and final products
p Measurement of crude oil during sampling for quality analysis
p Measurement at high temperatures (+750 °F), e.g. ADU / VDU outlets, overflash and sump measurement
p Measurement of heavy gasoil (HGO)/heavy vacuum gasoil (HVGO)
p Measurement at cracker feeders p Monitoring the flow of heat
transfer oil
Chemical industry p Flow measurement in hazardous areas p Flow measurement of inorganic
and organic media (even highly corrosive and toxic media)
Oil extraction p Flow measurement of crude and
water at separator outlets p Measurement at the wellhead
(up to 10% of gaseous volume) p Special low flow measurement
of wellhead injection media (e.g. methanol in very small doses)
p Flow measurement of injected water
p Flow measurement of condensate p Measurement on high pressure
systems
Natural gas extraction and processing
p Measurement of injection media (monoethylamine, triethylene glycol, etc...)
p Measurement of reservoir water p Measurement of LNG
F704.316 SE and F808 for hazardous areas
Operating temperature: Transmitters: Transducers:
F704.316SE: -40 ° F to +140° F; F808: -4 ° F to +120 ° F from -300 ° F up to +750 ° F and beyond
Flow channels: 1 or 2
Hazardous Area Classification:
F704.316SE: FM Class I, Div. 2 F808: FM Class I, Div. 1
Inputs (F808 none):
Outputs:
A variety of combinations are available from the following: current (0/4 mA ... 20 mA), voltage, frequency, pulse, alarm
For F704.316SE: Maximum 4. Available are: Temperature (Pt 100/1000 4-wire), current, voltage For F808: Current, Binary, Frequency
Communication: HART, ModBus
FLEXIM is an active leader in many areas of process instrumentation. As a worldwide pioneer in the non- intrusive flow measurement of liquids and gases, FLEXIM has been leading the way in ultrasonic clamp-on flow metering for more than 20 years. In addition to non-intrusive flow mea- surement, FLEXIM specializes in innovative online process analyzers using ultrasonic technology and refractometry.
Sustainable and progressive
measurement technology
Year after year, the Berlin based com-pany continues its substantial invest-ment in research and development in order to maintain and further impro-ve its position as an industry leader. In keeping with its core principles, FLEXIM takes customer feedback very seriously. Every generation of FLEXIM products is directly driven by customer and industry needs.
The FLEXIM commitment to customer service
FLEXIM considers itself not only a manufacturer of measuring instru- ments, but also a provider of techni-cal and consulting services. These services include instrument rentals, onsite measurements, lab- oratory analysis, project handling, training, commissioning and consul-ting services. The company’s focus and dedication is directed towards providing the highest quality equip-ment with the best support and service possible.
BULI
QUID
V8-2
US
08/
2016
S
ubje
ct to
cha
nge
with
out n
otifi
catio
n
FLEXIM________
In partnership with you
FLEXIM AMERICAS Corporation Headquarter 250-V Executive Drive Edgewood, NY 11717 Phone: (631) 492-2300
FLEXIM has offices located throughout North America.
Please have a look for your local representative at:
www.flexim.com
or call us at:
1-888-852-PIPE