ISOMETRIC VIEW
ISOMETRIC VIEW
NOTE : REFER SHEET-2 FOR ITEM NUMBERING AND SHEET-3 FOR OVERALL DIMENSIONS
APPROX. TOTAL WEIGHT: 1810 LBS
NOTES: UNLESS OTHERWISE SPECIFIED
1. MATERIAL: NONE2. PROCESS: NONE3. FINISH: REFER PURCHASE ORDER4. PART TO BE CLEAN AND FREE OF ALL FOREIGN MATTER.5. REMOVE ALL BURRS AND BREAK SHARP EDGES TO AN EQUIVALENT OF R.010 MAX.6. DIMENSIONS APPLY PRIOR TO PROCESSING AND FINISHING.
.25 A B C
ITEM NO. PART NUMBER DESCRIPTION QTY. WEIGHT/EACH
1 TP1000-0005SS SUPPORT POLE 3 112
2 TP1000-0001SS CROSS MEMBER, ROOF 3 78
3 TP1000-0002SS FRONT CONNECTOR, ROOF 2 70
4 TP1000-0004SS REAR CONNECTOR, ROOF 2 110
5 TP1001 - CHANNEL MOUNT BACK WALL WALL ASSEMBLY W/ CHANNEL MOUNT 1 262
6 BASE PLATE COVER ASSEMBLY, POLE BASE PLATE COVER ASSEMBLY, POLE 3 3
7 TP3101 BENCH ASSEMBLY, CANTILEVERED 1 81
8 TP1000-0003AL END CAP, APPROACH (RIGHT) 1 10
9 TP1000-0004AL END CAP, EXIT (LEFT) 1 10
10 TP1300-0001DE DEGLAS ROOF ASSEMBLY 1 101
11 TP1300-0001AL FLASHING, DEGLAS/GLASS ROOF ASSEMBLY 1 1
12 EX1.05 R4 TOP FRONT COMPONENT 158.5" 1 22
13 EX1.03 R2 BOTTOM BACK COMPONENT 158.5" 1 37.36
14 EX1.04 R1 TOP BACK COMPONENT 158.5" 1 37.96
15 EX1.06 R2 BOTTOM FRONT COMPONENT 158.5" 1 38.67
16 EX1.02 SUN SHADE, 158.5" 2 46
17 TP1000-0001ST-00001 EXTRUSION MOUNTING CLIP 3 0.5
18 TP1000-0001ST-00002 EXTRUSION HANGING CLIP 3 0.7
19 TP1300-0002WD WOOD SOFFIT ROOF ASSEMBLY W/ LED LIT BARS 1 130
20 TP1000-0005AL DRIP CAP, APPROACH (RIGHT) 1 0.1
21 TP1000-0006AL DRIP CAP, EXIT (LEFT) 1 0.1
22 TP1000-0001SG/0002SG SYSTEM ICON 1 17
23 TP1000-0001EL ELECTRICAL BOX ASSEMBLY 1 13
24 1000662 LED LITE BAR - 10' PIGTAIL 2 --
25 1000663 LITE BAR - POWER SUPPLY 1 --
26 TP1300-0001HA HARDWARE PACKAGE, GENERAL ASSEMBLY/INSTALL 1 N/A
TRANSIT SHELTER
DATE
CUSTOMER APPROVAL
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF LUCID MGMT GROUP. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF LUCID MGMT GROUP IS PROHIBITED.
1-855-335-8243
T3C SHELTER GRID WITH SINGLE BACK WALL
REVA
TP1300 PRODUCT ASSEMBLY
REFER TO ACCOMPANYING P.OFOR SPECIFIC INSTRUCTIONS
UNLESS OTHERWISE SPECIFIED-INTERPRET DRAWING PER ASME Y14.5-2009-INTERPRET MODEL PER ASME Y14.41-2003 -UNTOLERANCED DIMENSIONS ARE BASIC-DIMENSIONS ARE IN INCHES
-GENERAL TOLERANCE
PART NAME
TP1300 PRODUCT ASSEMBLY
PART REVISION
A
DRAWN BY GURU
APPROVALS IN PDM DATABASE
THIRD ANGLE PROJECTION
1 of 3
-
1:30
LMG Lucid Mgmt Groupwww.lucidmanagementgroup.com
DWG#:
TITLE :
WEIGHT [LBS]
SCALE
SHEET
:
::
:
PRODUCT
STATUS RELEASED
DO NOT SCALE DRAWING
SALES : DARREN PENNERPRODUCT ASSEMBLY:PART TYPE
DATE 11-01-2016
EXPLODED VIEW
NOTE: ITEM NUMBER 24, 25, 26 ARE NOT SHOWN IN EXPLODED VIEW
10 2 17 12 14 4
8
20
16
22
13
15
5
716
19
3
11
9
21
18
23
TRANSIT SHELTER
DATE
CUSTOMER APPROVAL
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF LUCID MGMT GROUP. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF LUCID MGMT GROUP IS PROHIBITED.
1-855-335-8243
T3C SHELTER GRID WITH SINGLE BACK WALL
REVA
TP1300 PRODUCT ASSEMBLY
REFER TO ACCOMPANYING P.OFOR SPECIFIC INSTRUCTIONS
UNLESS OTHERWISE SPECIFIED-INTERPRET DRAWING PER ASME Y14.5-2009-INTERPRET MODEL PER ASME Y14.41-2003 -UNTOLERANCED DIMENSIONS ARE BASIC-DIMENSIONS ARE IN INCHES
-GENERAL TOLERANCE: REFER SHEET-1
PART NAME
TP1300 PRODUCT ASSEMBLY
PART REVISION
A
DRAWN BY GURU
APPROVALS IN PDM DATABASE
THIRD ANGLE PROJECTION
2 of 3
-
1:35
LMG Lucid Mgmt Groupwww.lucidmanagementgroup.com
DWG#:
TITLE :
WEIGHT [LBS]
SCALE
SHEET
:
::
:
PRODUCT
STATUS RELEASED
DO NOT SCALE DRAWING
SALES : DARREN PENNERPRODUCT ASSEMBLY:PART TYPE
DATE 11-01-2016
323.86mm
12 3/4"
1905mm
75"
1651mm65"
BENCH WIDTH
3644.9mm143 1/2"POST C to C
1822.45mm
71 3/4"
AREA FOR GRAPHICS/STOP DESIGNATIONW 34 1/4" x H 8 3/4"
C
4025.9mm158 1/2"
OVERALL LENGTH
2457.79mm
96 3/4"
285.75mm11 1/4"
127mm5"
2297.94mm
90 1/2"
1966.32mm77 7/16"
ROOF DEPTH
482.6
19 3/16"
3124.1mm
123" 281.31mm
11 1/16"BENCH DEPTH
THREADED ROD AND NUTS USED TOACCOMMODATE FOR SITE SLOPE(BASE PLATE COVER NOT SHOWN)
A
B
PERSPECTIVE VIEW
TRANSIT SHELTER
DATE
CUSTOMER APPROVAL
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF LUCID MGMT GROUP. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF LUCID MGMT GROUP IS PROHIBITED.
1-855-335-8243
T3C SHELTER GRID WITH SINGLE BACK WALL
REVA
TP1300 PRODUCT ASSEMBLY
REFER TO ACCOMPANYING P.OFOR SPECIFIC INSTRUCTIONS
UNLESS OTHERWISE SPECIFIED-INTERPRET DRAWING PER ASME Y14.5-2009-INTERPRET MODEL PER ASME Y14.41-2003 -UNTOLERANCED DIMENSIONS ARE BASIC-DIMENSIONS ARE IN INCHES
-GENERAL TOLERANCE: REFER SHEET-1
PART NAME
TP1300 PRODUCT ASSEMBLY
PART REVISION
A
DRAWN BY GURU
APPROVALS IN PDM DATABASE
THIRD ANGLE PROJECTION
3 of 3
-
1:40
LMG Lucid Mgmt Groupwww.lucidmanagementgroup.com
DWG#:
TITLE :
WEIGHT [LBS]
SCALE
SHEET
:
::
:
PRODUCT
STATUS RELEASED
DO NOT SCALE DRAWING
SALES : DARREN PENNERPRODUCT ASSEMBLY:PART TYPE
DATE 11-01-2016