2 www.novatop-system.cz

NOVATOP ACOUSTIC

OBSAH

NOVATOP ACOUSTIC Akustické panely

TECHNICKÁ DOKUMENTACE

Datový list – popis, profi ly, dřeviny .................................................................................................................................................................... 3–4

Specifi kace materiálů v panelech ............................................................................................................................................................................. 5

Formáty ............................................................................................................................................................................................................................ 6

Datový list – skladby panelů, diagramy zkoušek, řezy profi lů .............................................................................................................. 7–13

Rázové zkoušky ........................................................................................................................................................................................................... 14

Výkresy profi lů ...................................................................................................................................................................................................... 15-18

Specifi kace kvalit (smrk, jedle) ...................................................................................................................................................................... 19–20

Povrchová úprava .............................................................................................................................................................................................. 21–22

Barvy kazet minerální vlny .................................................................................................................................................................................... 23

NÁVOD K MONTÁŽI

1. Pomůcky pro montáž .......................................................................................................................................................................................... 24

2. Obecné informace ................................................................................................................................................................................................ 24

3. Bezpečnost práce .................................................................................................................................................................................................. 24

4. Typy aplikací ........................................................................................................................................................................................................... 24

5. Doporučení k montáži ........................................................................................................................................................................................ 25

6. Typy aplikací ........................................................................................................................................................................................................... 25

7. Montáž ...................................................................................................................................................................................................................... 25

8. Kotvení vodorovné a svislé konstrukce ................................................................................................................................................. 26–27

9. Ruční obrábění panelů ....................................................................................................................................................................................... 28

10. Detaily rohů ................................................................................................................................................................................................... 29–30

11. Návaznost stropních a stěnových panelů ................................................................................................................................................. 30

12. Ukončení ............................................................................................................................................................................................................... 30

13. Doporučené aplikace ........................................................................................................................................................................................ 30

ZPRACOVÁNÍ, BALENÍ, SKLADOVÁNÍ, PŘEPRAVA, MANIPULACE .............................................................................................. 31

CERTIFIKÁTY, OSVĚDČENÍ A PROTOKOLY

Jednotlivé certifi káty, osvědčení a protokoly jsou ke stažení na novatop-system.cz. Verze: 06/2019

Page 3: NOVATOP ACOUSTIC

3www.novatop-system.cz

NOVATOP ACOUSTIC

DATOVÝ LIST

POPIS

NOVATOP ACOUSTIC jsou panely určené k opláštění interiéru optimalizující akustické vlastnosti daného prostoru. Panely jsou

vyrobené z třívrstvé masivní desky (SWP) perforované do různých profi lů. Profi ly jsou vrtány či frézovány. Podíl perforované

plochy a tvar profi lu se u jednotlivých typů liší. Panely lze ve výrobě doplňovat absorbérem, celková skladba panelu se volí dle

akustických požadavků projektu. Prefabrikovaný panel je připraven přímo k montáži.

Smrk – pohledová kvalita

Jedle – pohledová kvalita

SUZANNA

rastr

[mm]

rozměr drážky

[mm]

perforace

[%]

plošná

hmotnost

[kg/m2]

15/33 15 x 300 18 7,6

GIULIA

rastr

[mm]

rozměr drážky

[mm]

perforace

[%]

plošná

hmotnost

[kg/m2]

8/33 8 x 600 10 8,2

MARILYNE 8/25

rastr

[mm]

rozměr drážky

[mm]

perforace

[%]

plošná

hmotnost

[kg/m2]

8/25 8 x 420 20 7,5

MARILYNE 4/12

rastr

[mm]

rozměr drážky

[mm]

perforace

[%]

plošná

hmotnost

[kg/m2]

4/12 4 x 420 20 7,5

MARILYNE SPECIAL

rastr

[mm]

rozměr drážky

[mm]

perforace

[%]

plošná

hmotnost

[kg/m2]

4/16-21-16-

12-16-24-12

4 x 420 16 11,3

PROFILY DŘEVINY

Specifi kace kvalit viz str. 19–20

Page 4: NOVATOP ACOUSTIC

4 www.novatop-system.cz

TINA

rastr

[mm]

rozměr drážky

[mm]

perforace

[%]

plošná

hmotnost

[kg/m2]

170 x 580 580 x 580 36 5,6

BEATA

rastr

[mm]

rozměr drážky

[mm]

perforace

[%]

plošná

hmotnost

[kg/m2]

8/ 25 8 x ℓ

není skrzodrazivý prvek 13,2

LUCY 8/16-16

rastr

[mm]

průměr otvoru

[mm]

perforace

[%]

plošná

hmotnost

[kg/m2]

8/16-16 8 20 7,5

LUCY 10/32-32

rastr

[mm]

průměr otvoru

[mm]

perforace

[%]

plošná

hmotnost

[kg/m2]

10/32-32 10 8 8,6

LUCY 16/32-32

rastr

[mm]

průměr otvoru

[mm]

perforace

[%]

plošná

hmotnost

[kg/m2]

16/32-32 16 21 7,3

PROFILY

NOVATOP ACOUSTIC

DATOVÝ LIST

MARILYNE 4/12 – detail

z lícové strany desky

MARILYNE – detail s fi bertexem

75 g/m2 + Steico Flex tl. 50 mm

z rubové strany desky

MARILYNE 8/25 – detail s fi bertexem

75 g/m2 + Steico Flex tl. 50 mm

Page 5: NOVATOP ACOUSTIC

5www.novatop-system.cz

NOVATOP ACOUSTIC

SPECIFIKACE MATERIÁLŮ V PANELECH

TŘÍVRSTVÁ MASIVNÍ DESKA

TECHNICKÉ PARAMETRY AGROP SWP

Požadavky EN 13353, EN 13986

Provozní třídy SWP/1, SWP/2, podle EN 13353

Lepení D4 podle EN 204

Lepidlo PVAc dle EN 204

Typy dřevin Smrk, jedle

Kvalita povrchu

Pohledová interiérová (odpovídá B).

Třídění kvalit dle interních předpisů

AGROP NOVA a.s.

Standardní formáty [mm]

Tloušťka: 19, 27

Šířka: 625, 1250, 2500

Délka: 2500, 3000 (pouze jedle), 5000

Povrch broušeno K 100

Vlhkost 10 ± 3%

Emisní třída formaldehydu E1 podle EN 717-1

Reakce na oheň D-s2, d0 podle EN 13 501-1

DŘEVOVLÁKNITÁ IZOLACE

TECHNICKÉ PARAMETRY STEICO Flex Therm SD

Požadavky EN 13171

Hustota [kg/m3] 50 160

Deklarovaný součinitel tepelné vodivosti [ W/mK] 0,038 0,040

Tloušťka [mm] 50 20

Reakce na oheň E podle EN 13501-1

NETKANÉ TEXTILIE

TECHNICKÉ PARAMETRY FIBERTEX FIBERTEX Acoustic® 450 FIBERTEX Acoustic® 75

Plošná hmotnost [g/m2] 450 75

Materiál 100% polyester (černá barva)

Mez pevnosti [N] 425/800 25/35

Akustický odpor [Ns/m3] 600 250

Tloušťka [mm] 2,5 0,3

Reakce na oheň B-s1,d0 podle EN 13501-1 B-s1,d0 podle EN 13501-1

KAZETY Z MINERÁLNÍ VLNY

TECHNICKÉ PARAMETRY Eurocoustic TONGA TECHNICKÉ PARAMETRY Ursa Aku:

Hustota [kg/m3] 75 21

Materiálminerální vlákna, lícní povrch povlak skelných

vláken

Skelná vlna, jednostranně kašírovaná

netkanou textilií

Třída pohltivosti A podle ISO 11654 A podle ISO 11654

Emisní třída formaldehydu E1 podle ISO 13964 E1 podle ISO 13964

Standardní formáty [mm]

Tloušťka: 22, 40 Tloušťka: 20/30/40/50

Šířka: 600 Šířka: 600

Délka: 600, 1200 Délka: 1250

Reakce na oheň (bílé odstíny) A1-s1, d0 podle EN 13501-1 A1-S1, D0 podle EN 13501-1

Reakce na oheň (barevné odstíny) A2-s1, d0 podle EN 13501-1 A1-S1, D0 podle EN 13501-1

Upozornění: Minimální množství kazet jedné barvy je účtováno po balících (1 balík: 24 ks/ 600 x 600 mm/ celkem 8,64 m2).

Barvy kazet z minerální vlny viz str. 23

Page 6: NOVATOP ACOUSTIC

6 www.novatop-system.cz

NOVATOP ACOUSTIC

FORMÁTY

STANDARDNÍ FORMÁTY SMRK

STANDARDNÍ FORMÁTY JEDLE

25

00

625

25

00

1250

50

00

625

50

00

1250

50

00

2500

max. formát

30

00

25

00

625

625

30

00

25

00

1250

1250

50

00

625

50

00

1250

50

00

2500

max. formát

Standardní šířky (mm): 625, 1250, 2500

Standardní délky (mm): 2500, 5000

U všech formátů je nutné zohlednit tvar a provedení profi lu při napojování. Min. šířka pro profi l Tina je 1250 mm.

U profi lu Giulia nabízíme standardní délky 3000 a 5000 mm.

Standardní šířky (mm): 625, 1250, 2500

Standardní délky (mm): 2500, 3000, 5000

STANDARDNÍ FORMÁTY PROFILU LUCY Průměr vrtání (mm) Rozměr (mm) Smrk Jedle

8/16-16

624 x 2496

624 x 2992

624 x 4992

1248 x 2496

1248 x 2992

1248 x 4992

Průměr vrtání (mm) Rozměr (mm) Smrk Jedle

10/32-32

16/32-32

608 x 2496

608 x 2976

608 x 4992

1248 x 2496

1248 x 2976

1248 x 4992

Page 7: NOVATOP ACOUSTIC

7www.novatop-system.cz

NOVATOP ACOUSTIC

DATOVÝ LIST

Číslo

/profi lSkladba

Ce

lko

vá t

lou

šťka

[m

m]

Du

tý p

rost

or

Plo

šná

hm

otn

ost

[kg

/m2]

Diagram Řez

1.1

PR

OF

IL S

UZ

AN

NA

Vzduchová mezera

[30 mm]50

12,3Steico Therm SD

[ 20 mm]39

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,55

Třída pohltivosti D

1.2

PR

OF

IL S

UZ

AN

NA

Vzduchová mezera

[80 mm]100

12,3Steico Therm SD

[20 mm]39

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,55

Třída pohltivosti D

2.1

PR

OF

IL G

IUL

IA

Vzduchová mezera

[30 mm]50

13,1Steico Therm SD

[20 mm]39

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,4

Třída pohltivosti D

2.2

PR

OF

IL G

IUL

IA

Vzduchová mezera

[80 mm]

100 13,1Steico Therm SD

[20 mm]39

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,4

Třída pohltivosti D

Číslo protokolu 6708-10-1

Číslo protokolu 6708-10-1

Číslo protokolu 6708-10-1

Číslo protokolu 6708-10-1

Page 8: NOVATOP ACOUSTIC

8 www.novatop-system.cz

NOVATOP ACOUSTIC

DATOVÝ LIST

Číslo

/profi lSkladba

Ce

lko

vá t

lou

šťka

[m

m]

Du

tý p

rost

or

Plo

šná

hm

otn

ost

[kg

/m2]

Diagram Řez

3.1

PR

OF

IL M

AR

ILY

NE

8/2

5

Vzduchová mezera

[30 mm]

50

12,8

Příčný hranol

[21 mm]

40Steico Therm SD

[20 mm]

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,75

Třída pohltivosti C

3.2

PR

OF

IL M

AR

ILY

NE

8/2

5

vzduchová mezera

[30 mm]

50

10

Příčný hranol

[21 mm]

40tkanina Fibertex

450 g [2,5 mm]

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,7

Třída pohltivosti C

3.3

PR

OF

IL M

AR

ILY

NE

8/2

5

vzduchová mezera

[179 mm]

200 10

Příčný hranol

[21 mm]

40tkanina Fibertex

450 g [2,5 mm]

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,75

Třída pohltivosti C

Číslo protokolu 311/12

Číslo protokolu 312/12

Číslo protokolu 313/12

Page 9: NOVATOP ACOUSTIC

9www.novatop-system.cz

NOVATOP ACOUSTIC

DATOVÝ LIST

Číslo

/profi lSkladba

Ce

lko

vá t

lou

šťka

[m

m]

Du

tý p

rost

or

Plo

šná

hm

otn

ost

[kg

/m2]

Diagram Řez

3.4

PR

OF

IL M

AR

ILY

NE

8/2

5

Vzduchová mezera

[0 mm]

50

12,1

Příčný hranol

[50 mm]

69

Steico fl ex

[50 mm]

Tkanina Fibertex

75 g [0,3 mm]

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,85

Třída pohltivosti B

3.5

PR

OF

IL M

AR

ILY

NE

8/2

5

Vzduchová mezera

[150 mm]

200

12,1

Příčný hranol

[50 mm]

69

Steico fl ex

[50 mm]

Tkanina Fibertex

75 g [0,3 mm]

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,8

Třída pohltivosti B

3.6

MA

RIL

YN

E 4

/12

Vzduchová mezera

[50 mm]

70

10

Steico Therm SD

[20 mm]

40Příčný hranol

[21 mm]

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,75

Třída pohltivosti C

Číslo protokolu 315/12

Číslo protokolu 314/12

Číslo protokolu 056/16

Page 10: NOVATOP ACOUSTIC

10 www.novatop-system.cz

NOVATOP ACOUSTIC

DATOVÝ LIST

Číslo

/profi lSkladba

Ce

lko

vá t

lou

šťka

[m

m]

Du

tý p

rost

or

Plo

šná

hm

otn

ost

[kg

/m2]

Diagram Řez

3.7

MA

RIL

YN

E 4

/12

Vzduchová mezera

[50 mm]

70

10

Ursa Aku

[20 mm]

40Příčný hranol

[21 mm]

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,70

Třída pohltivosti C

3.8

MA

RIL

YN

E 4

/12

Vzduchová mezera

[70 mm]

90

10

Fibertex 450 g/m2

[3 mm]

40Příčný hranol

[21 mm]

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,65

Třída pohltivosti C

3.9

MA

RIL

YN

E S

PE

CIA

L

Vzduchová mezera

[72 mm]

92 14Příčný hranol

[42 mm]

61Steico Therm SD

[20 mm]

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,65

Třída pohltivosti C

Číslo protokolu 056/16

Číslo protokolu 056/16

0,00,10,20,30,40,50,60,70,80,91,01,11,21,3

63 125 250 500 1000 2000 4000 f (Hz)

αS (-)

Číslo protokolu 335/17

Page 11: NOVATOP ACOUSTIC

11www.novatop-system.cz

NOVATOP ACOUSTIC

DATOVÝ LIST

Číslo

/profi lSkladba

Ce

lko

vá t

lou

šťka

[m

m]

Du

tý p

rost

or

Plo

šná

hm

otn

ost

[kg

/m2]

Diagram Řez

3.1

0 M

AR

ILY

NE

SP

EC

IAL

Vzduchová mezera

[22 mm]

42 14Příčný hranol

[42 mm]

61Steico Therm SD

[20 mm]

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,65

Třída pohltivosti C

3.1

1 M

AR

ILY

NE

SP

EC

IAL

Vzduchová mezera

[2 mm]42

16,9Příčný hranol

[42 mm]61

Steico Therm SD

[2 x 20 mm]

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,65

Třída pohltivosti C

4.1

PR

OF

IL T

INA

Vzduchová mezera

[0–50 mm]

50 10Tonga

[40 mm]46

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,55

Třída pohltivosti D Číslo protokolu 309/12

Číslo protokolu 335/17

Číslo protokolu 335/17

Page 12: NOVATOP ACOUSTIC

12 www.novatop-system.cz

NOVATOP ACOUSTIC

DATOVÝ LIST

Číslo

/profi lSkladba

Ce

lko

vá t

lou

šťka

[m

m]

Du

tý p

rost

or

Plo

šná

hm

otn

ost

[kg

/m2]

Diagram Řez

5.1

PR

OF

IL B

EA

TA SWP deska

s drážkami [27 mm]27 11,4

Rozptylové prvky

6.1

LU

CY

ø1

0/3

2-3

2

Vzduchová mezera

[0 mm]

20 10Steico Therm SD

[20 mm]39

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,55

Třída pohltivosti D

6.2

LU

CY

ø1

0/3

2-3

2

Vzduchová mezera

[40 mm]60

10Ursa Aku 20 mm

[20 mm]39

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,35

Třída pohltivosti D

6.3

LU

CY

ø1

0/3

2-3

2

Vzduchová mezera

[50 mm]50

10Fibertex 450 g/m2

[3 mm]19

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,40

Třída pohltivosti D Číslo protokolu 054/16

0,00,10,20,30,40,50,60,70,80,91,01,11,21,3

63 125 250 500 1000 2000 4000 f (Hz)

αS (-)

Číslo protokolu 054/16

Číslo protokolu 054/16

0,00,10,20,30,40,50,60,70,80,91,01,11,21,3

63 125 250 500 1000 2000 4000 f (Hz)

αS (-)

0,00,10,20,30,40,50,60,70,80,91,01,11,21,3

63 125 250 500 1000 2000 4000 f (Hz)

αS (-)

Page 13: NOVATOP ACOUSTIC

13www.novatop-system.cz

NOVATOP ACOUSTIC

DATOVÝ LIST

Číslo

/profi lSkladba

Ce

lko

vá t

lou

šťka

[m

m]

Du

tý p

rost

or

Plo

šná

hm

otn

ost

[kg

/m2]

Diagram Řez

6.4

LU

CY

ø8

/16

-16

Vzduchová mezera

[50 mm]70

10Steico Therm SD

[20 mm]39

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,85

Třída pohltivosti B

6.5

LU

CY

ø8

/16

-16

Vzduchová mezera

[40 mm]60

10Ursa Aku

[20 mm]39

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,60

Třída pohltivosti C

6.6

LU

CY

ø8

/16

-16

Vzduchová mezera

[50 mm]50

10Fibertex 450 g/m2

[3 mm]19

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,55

Třída pohltivosti D

6.7

LU

CY

ø1

6/

32

-32

Vzduchová mezera

[0 mm]39

10Steico Therm SD

[20 mm]19

SWP s perforací

[19 mm]

Vážený činitel zvukové

pohltivosti [αw]

0,60

Třída pohltivosti C

Číslo protokolu 055/16

Číslo protokolu 055/16

Číslo protokolu 055/16

Číslo protokolu 282/17

0,00,10,20,30,40,50,60,70,80,91,01,11,21,3

63 125 250 500 1000 2000 4000 f (Hz)

αS (-)

0,00,10,20,30,40,50,60,70,80,91,01,11,21,3

63 125 250 500 1000 2000 4000 f (Hz)

αS (-)

0,00,10,20,30,40,50,60,70,80,91,01,11,21,3

63 125 250 500 1000 2000 4000 f (Hz)

αS (-)

Page 14: NOVATOP ACOUSTIC

14 www.novatop-system.cz

NOVATOP ACOUSTIC

RÁZOVÉ ZKOUŠKY

RÁZOVÁ ZKOUŠKA DOPADU BALONU

Rázová zkouška dopadu balonu pro použití ve sportovních halách a tělocvičnách od 2 m nad podlahou. Akustické panely

musí být umístěny na pevné dřevěné konstrukci, hranoly šířky 60 mm s osovou vzdáleností 500 mm. Kotvení akustických

panelů: min. 8 ks/m2 vruty 3,2 x 50 mm

Zkouška probíhala dle DIN 18032-3 (ÖNORM B 2608: 2012 05 01).

Všechny testované vzorky vyhověly požadavkům ČSN EN 13964

Číslo protokolu: 1701750-1

ZKOUŠENÉ VZORKY

Profi l DřevinaVýsledek rázové zkoušky

(házenkářský míč)

Marilyne 4/12 Smrk Vyhovělo

Marilyne 4/12 Jedle Vyhovělo

Marilyne 8/25 Smrk Vyhovělo

Marilyne 8/25 Jedle Vyhovělo

Suzanna Smrk Vyhovělo

Lucy 8/16 -16 Smrk Vyhovělo

500

Marilyne 4/12 Smrk

Marilyne 4/12 Jedle

Marilyne 8/25 Jedle

Marilyne 8/25 Smrk

Suzanna Smrk

Lucy 8/16-16 Smrk

Page 15: NOVATOP ACOUSTIC

15www.novatop-system.cz

SUZANNA

GIULIA

62

5

3000

100 300 200 300 200 300 200 300 200 300 200 300 100

19

514

7,5

15

33

,1

0

10

0

40

0

60

0

90

0

11

00

14

00

16

00

19

00

21

00

24

00

26

00

29

00

30

00

62

5

3000

19

514

48

33

200 600 400 600 400 600 200

0

20

0

80

0

12

00

18

00

22

00

28

00

30

0

NOVATOP ACOUSTIC

VÝKRESY

Page 16: NOVATOP ACOUSTIC

16 www.novatop-system.cz

NOVATOP ACOUSTIC

VÝKRESY

MARILYNE 8–25

MARILYNE 4–12

MARILYNE SPECIAL

62

5

3000

0

40

40

420

46

0

80

54

0

420

96

0

80

10

40

420

14

60

80

15

40

420

19

60

80

20

40

4202

46

080

25

40

420

29

60

30

00

40

40

1921

24

12

62

5

3000

0

40

40

420

46

0

80

54

0

420

96

0

80

10

40

420

14

60

80

15

40

420

19

60

80

20

40

420

24

60

80

25

40

420

29

60

30

00

40

61

19 42

24

214

4 1244

2412

4

16

16

16

62

5

3000

0

40

40

420

46

0

80

54

0

420

96

0

80

10

40

420

14

60

80

15

40

420

19

60

80

20

40

420

24

60

80

25

40

420

29

60

30

00

40

40

1921

48

24

,9

Page 17: NOVATOP ACOUSTIC

17www.novatop-system.cz

NOVATOP ACOUSTIC

VÝKRESY

TINA

BEATA

12

50

3000

19

613

33

53

35

58

0

85

85

580

66

5

170

83

5

580

14

15

170

15

85

580

21

65

170

23

35

580

29

15

85

30

000

10

58

01

0

62

5

3000

27

720

48

24

.9

Page 18: NOVATOP ACOUSTIC

18 www.novatop-system.cz

NOVATOP ACOUSTIC

VÝKRESY

LUCY ø10/32-32

LUCY ø8/16-16

LUCY ø16/32-32

����ø 10

16

32

32

32

32

16

2976

12

48

19

32

32

32

32

���

8

16

16

16

16

16

16

16

16

16

816

16

16

16

16

16

16

ø8

12

48

2992

19

����

�� �� ��

��

��

��

��

�� �� ��

��

��

��

16

ø 16

32 32 16

32

32

32

16

2976

12

48

19

Page 19: NOVATOP ACOUSTIC

19www.novatop-system.cz

NOVATOP ACOUSTIC

SPECIFIKACE KVALIT

SMRK – KVALITA POHLEDOVÁ INTERIÉROVÁ

Povrchové lamely jsou z řeziva vyšší kvality. Povrch je broušený s vyspravenými suky z větví rozdílných velikostí, uzavřený,

vytmelený, bez zabarvení. Dřeň je povolena v menší míře. Finální povrch profi lu je přebroušen. Drobné oděrky a otlaky do

hloubky 1 mm a plochy 10 mm2 jsou přípustné. Panely jsou při balení prokládány kartony.

Page 20: NOVATOP ACOUSTIC

20 www.novatop-system.cz

JEDLE BĚLOKORÁ – KVALITA POHLEDOVÁ INTERIÉROVÁ

Jedlová deska se vyznačuje jemnou vyváženou strukturou bez suků. Povrchové lamely bez přirozených vad dřeva (neobsahují

pryskyřici, pryskyřičné kanálky, smolníky) jsou napojovány cinkovaným spojem. Finální povrch profi lu je přebroušen. Je

vhodná zejména pro interiéry a má podobné mechanické vlastnosti jako smrk.

NOVATOP ACOUSTIC

SPECIFIKACE KVALIT

Page 21: NOVATOP ACOUSTIC

21www.novatop-system.cz

NOVATOP ACOUSTIC

POVRCHOVÁ ÚPRAVA

Akustické panely jsou standardně dodávány bez povrchové úpravy. Povrch může být ošetřen běžnými nátěrovými hmotami

na dřevo pro použití v interiéru.

DOPORUČOVANÁ POVRCHOVÁ ÚPRAVA

Adler Lingovit Interior UV 100

– produkt značky Adler, která si zakládá na kvalitě a udržitelnosti

– velice nízké hodnoty VOC

– vodou ředitelná barva pro použití v interiéru

– nová trojnásobná ochrana proti UV záření (UV-absorbér, fyzikální UV ochrana převážně bezbarvými pigmenty,

stabilizátor Ligninu)

– podrobné informace viz Technický list výrobce (link v PDF) popř. na webových stránkách výrobce.

TYP POVRCHOVÉ ÚPRAVY

Základní nátěr – nanášen válečkem – určen k dokončení po montáži na stavbě

Finální nátěr – dvě stříkané vrstvy s mezibroušením

ODSTÍNY

Natur – transparentí bez barevných pigmentů

Zugspitz a Mont Blanc – s bílými pigmenty

Page 22: NOVATOP ACOUSTIC

22 www.novatop-system.cz

NOVATOP ACOUSTIC

POVRCHOVÁ ÚPRAVA

Základní nátěr – Adler Natur

Základní nátěr – Adler Zugspitze

Základní nátěr – Adler Mont Blanc

Finální nátěr – Adler Natur

Finální nátěr – Adler Zugspitze

Finální nátěr – Adler Mont Blanc

Page 23: NOVATOP ACOUSTIC

23www.novatop-system.cz

EC06 EC05 EC04 EC03 EC02 EC01 EC13 EC12 EC11 EC10

EC9 EC8 EC7 EC21 EC20 EC19 EC18 EC17 EC16 EC15

EC14 EC27 EC26 EC25 EC24 EC23 EC22 EC33 EC32 EC31

EC30 EC29 EC28 EC40 EC39 EC38 EC37 EC36 EC35 EC34

EC46 EC45 EC44 EC43 EC42 EC41 W08 W082

Upozornění: Minimální množství kazet jedné barvy je účtováno po balících (1 balík: 24 ks/ 600 x 600 mm/ celkem 8,64 m2).

NOVATOP ACOUSTIC

BARVY KAZET Z MINERÁLNÍ VLNY

Page 24: NOVATOP ACOUSTIC

24 www.novatop-system.cz

– V případě aplikace na vodorovnou i svislou konstrukci

počítáme s dilatací mezi panelem a podkladem.

– U aplikace panelů na velké plochy je třeba klást důraz na

správné založení a vzájemné stahování jednotlivých panelů.

– Je třeba si rozmyslet pozici elektroinstalace a nachystat

všechny prostupy a otvory.

– Spoje panelů doporučujeme přesazovat viz obrázky.

Nepřesazené spoje jsou náročnější na přesnost a provedení.

(Více vyniknou případné nerovnosti konstrukce budovy).

Nedoporučujeme Doporučujeme

Vodorovná konstrukce (strop) – přesazené spoje

Svislá konstrukce (stěna) – horizontální uložení

Svislá konstrukce (stěna) – vertikální uložení

NOVATOP ACOUSTIC

NÁVOD K MONTÁŽI

Návod na montáž obsahuje základní informace a doporučení.

Zodpovědnost za správné provedení přebírá realizační

společnost, která dodržuje aktuální technické normy.

1 POMŮCKY PRO MONTÁŽ

– Vruty s úzkou hlavou – Akušroubovák

– Vodováha

– Žebříky, zvedací plošiny, mobilní lešení

– Doporučený počet osob min. 2

2 OBECNÉ INFORMACE

Doporučujeme:

– Používat rukavice při práci kvůli případnému znečištění

panelů popř. zadření si třísky.

– Montáž panelů provádět až po všech „mokrých“

a  „špinavých“ procesech.

– Znečištěná místa na panelech lokálně otřít vlhkým

hadrem popř. přebrousit brusným papírem.

– Opracovávat panely všemi běžnými dřevoobráběcími

nástroji a stroji a povrchově upravovat běžnými postupy

jako masivní dřevo.

– Relativní vlhkost vnitřního prostředí při montáži do 55 %

při 20 °C.

Nedoporučujeme:

– Šlapat po pohledových plochách panelů ani je jinak

znečišťovat.

– Vystavovat panely přímému slunečnímu záření, zamezí

se tak případným barevným změnám.

Skladování:

– Panely je nutné skladovat v suchu a musí být ochráněny

před povětrnostními vlivy.

– Panely je nutné skladovat na pevných a vyrovnaných

plochách s možností bezpečného

přístupu a manipulace.

– Likvidace obalových materiálů musí probíhat podle

místních nařízení a směrnic o odpadovém hospodářství.

3 BEZPEČNOST PŘI PRÁCI

Při manipulaci s panely je nutno:

– Dodržovat veškerá bezpečnostní opatření.

– Používat ochranné pomůcky.

– Dbát zvýšené opatrnosti při práci ve výškách a na

zdvižných plošinách.

– Zabezpečit panely proti pádu.

4 TYPY APLIKACÍ

Vodorovná a svislá konstrukce

Page 25: NOVATOP ACOUSTIC

25www.novatop-system.cz

Plechový rošt

Plechový rošt kontaktní

Plechový rošt zavěšený

MONTÁŽ

– Při zakládání panelů je nutno dodržet rovinnost, nejlépe

pomocí nataženého provázku, aby při dalším dosazování

panelů nevznikaly spáry mezi panely.

– Při montáži je třeba dodržovat návaznost drážek jednoho

panelu na druhý.

– Pro vzájemné spojení panelů jsou dodávány buď „vložená

pera“ do připravených drážek nebo speciální spojovací

prvky „lamelky“ do připravených lokálních drážek.

– Je nutné zohlednit pozici svlaků pro eliminaci volných

konců.

– Doporučujeme spočítat, jak velký vznikne dořez na konci

obkládané plochy, aby nevznikl jen malý pásek, který

není možné přimontovat.

– Doporučujeme používat jen zbytky nad 500 mm.

Schéma kladení a práce s ořezy panelů

Navazování panelů

NOVATOP ACOUSTIC

NÁVOD K MONTÁŽI

DOPORUČENÍ K MONTÁŽI

Příprava podkladního roštu

– Při přípravě roštu je třeba počítat s nerovnostmi podkladu

a rozteč první latě zmenšit tak, aby bylo možné šířkově

upravit první akustický panel.

– Na podklad určený k obložení připravíme vyrovnávací

rošt v rastru, který si vyměříme v závislosti na rozměrech

akustických panelů a plochy určené k obložení. Mezera

mezi podkladem a akustickým panelem může sloužit

také k vedení elektroinstalací popř. jiných rozvodů.

– Po instalaci podkladního roštu nezapomeneme označit

žebra na viditelných místech tak, aby byly viditelné i po

zakrytí akustickými panely.

Rastr vyrovnávacího roštu – příčný (pro Giulia – 1000 mm)

TYPY APLIKACÍ

Bez roštu (např. na NOVATOP, OSB, SDK)

Dřevěný rošt (podhled)

Dřevěný rošt kontaktní

Dřevěný rošt zavěšený

min. 500 mm(používat zbytky nad 500 mm )

ST NA

STROP

635 625

625

5-15 dilatace

40-60

5

6

6.1

6.2

7

6.3

470500500

Dilatace

5-15

10

-30

Page 26: NOVATOP ACOUSTIC

26 www.novatop-system.cz

NOVATOP ACOUSTIC

NÁVOD K MONTÁŽI

Kotvení sponami do drážek

– Min. délka spon je 38 mm (spony např. od fi rmy Reich

1,8/38 mm).

– Kotvení sponami doporučujeme použít např. u profi lu

Marilyne, kde je tloušťka drážky jen 4 mm a nelze u něj

použít vruty do drážky. Vhodné je použít vzduchovou

pistoli s úzkou koncovkou (např. fi rmy Reich typ 3428).

– Min. počet spon 10 ks/m2 (cca 2 ks spony 1,8/38 na

1 svlak šířky 80 mm při rozteči podkladového roštu

625 mm a rozteči svlaků 500 mm od sebe).

KOTVENÍ

– Akustické panely lze kotvit na vodorovné a svislé

konstrukce s pomocí kotevních vrutů, sponami do drážek

anebo lepením dle typu konstrukcí. Dbáme na to, aby

spojovací prostředky byly v jedné linii a pokud možno

bez porušení povrchu akustického panelu.

– Upozornění: na stropní akustické panely nemohou být

zavěšena břemena ( světla, zářivky atd.), veškerá břemena

musí být zavěšena na nosné konstrukci!

VODOROVNÉ KONSTRUKCE

Kotvení vruty

– V případě, že jsou vruty aplikovány do drážky, je nutné

používat vruty s rozměrem hlavy menší než je drážka

panelu, aby hlavy drážku neporušily (např. od fi rmy

HPM-TEC, Rothoblaas, Würth).

– Min. rozměr vrutů je 3,2 x 50 mm.

– Min. počet vrutů je 8 ks/m2. (Obecně platí pravidlo

vrutovat každý svlak panelu tak, aby se panel neprohýbal.)

– V ploše panelu doporučujeme používat vruty min. 4 x 70 mm

z nerezavějící oceli nebo žárově zinkované. Min. počet

vrutů je 8 ks/m2.

Spony do drážky s podkladním roštem (Marilyne 4-12)

Vzduchová pistole s úzkou koncovkou (Např. Reich)

Na 1 svlak je možné umístit 2 spony, jejich rozteč musí být min. 25 mm.

Spony

Vruty do boční drážky s podkladním roštem

Vruty v drážce

Vruty v ploše desky

8

8.1

Page 27: NOVATOP ACOUSTIC

27www.novatop-system.cz

NOVATOP ACOUSTIC

NÁVOD K MONTÁŽI

Lepení

– Systém lepení akustických panelů pomocí speciálního

lepícího systému s podkladním roštem (např. SIKA TACK).

Lepení se řídí pokyny výrobců lepícího systému.

SVISLÉ KONSTRUKCE

Kotvení vruty

– Stejně jako u vodorovných konstrukcí je i usvislých

konstrukcí důležité, aby byly vyrovnány podkladové latě.

Je třeba počítat s dilatačními spárami jak od podlahových

konstrukcí, tak od stropních konstrukcí.

– Kotvení svislých konstrukcí můžeme provádět vruty,

sponami tak i lepením.

– Min. počet vrutů je 8 ks / m2.

Vruty v ploše desky Vruty v drážce

Vruty v drážce na SOLID Vruty do boční drážky

Kotvení sponami do drážek

– Min. počet spon je 10 ks / m2.

Spony do drážky s podkladovým roštem

Lepení

– Systém lepení akustických panelů pomocí speciálního

lepícího systému s podkladním roštem (např. SIKA TACK).

Lepení se řídí pokyny výrobců lepícího systému.

Lepení

např.stěna SolidNovatop- vertikálně

8.2

Page 28: NOVATOP ACOUSTIC

28 www.novatop-system.cz

NOVATOP ACOUSTIC

NÁVOD K MONTÁŽI

RUČNÍ OBRÁBĚNÍ PANELŮ

Obecné informace

– Panely lze obrábět běžnými způsoby a běžným ručním

nářadím.

– Panely lze řezat, vrtat, brousit, apod. jako masivní dřevo.

– Pro kvalitnější plochy při obrábění (vrtání, řezání – příčné

a šikmé) lze použít ochranné lamely do drážek panelu,

které zamezí vyštípnutí a otřepení řezu.

– Při jakémkoli vývrtu pro elektroinstalaci nebo jiný prostup

se přesvědčte, zda je vývrt ve správné pozici a zda těmto

otvorům nebrání další konstrukce (zavěšovací rošty,

třmeny apod.).

Příčné a šikmé řezání

– Ideální je vést řez v místě svlaku, u volných konců nad 150 mm

doporučujeme přidat dodatečné svlaky pro eliminaci

zkroucení volných konců lamel.

– U příčných a šikmých řezů je vhodné používat ochranné

lamely do drážek akustických panelů. Doporučení:

abychom zabránili třepení pohledových ploch, řežeme

panel ze zadní strany.

– Při řezání je nutné použít příložku nebo vodící lištu, která

zaručí rovný řez.

– U křivkových řezů lze použít přímočaré kmitací pily

(přímočarky). Upozornění: Zde je větší riziko třepení!

Řezání s ochrannými lamelami nebo jemnějším řezným

kotoučem

Řezání ze zadní strany

Vývrty, vykružování

– Do akustických panelů lze vytvářet vývrty a otvory

různých průměrů pomocí vrtáků, vykružováků, frézek

apod.

– Při opracování je vhodné používat ochranné lamely do

drážek akustických panelů viz obrázek.

Vykružování s ochrannými lamelami

Detaily rohů

Vnější roh ostrý

– Rohy jsou zaříznuté pod úhlem 45°.

– Spoj je nutné provést co nejpřesněji, jsou povoleny

minimální odchylky v rovinnosti podkladu.

– Při řezání pod úhlem je nutné použít nový, ostrý řezný

kotouč a panel řezat zezadu, aby nebyly otřepeny čelní

– viditelné hrany panelu.

– Pro řezání doporučujeme použít vodící lištu nebo

pravítko.

– Rohy je také možné nachystat na stolní okružní

formátovací pile s předřezem.

– Doporučujeme vést řez v místě svlaku.

9

10

Page 29: NOVATOP ACOUSTIC

29www.novatop-system.cz

NOVATOP ACOUSTIC

NÁVOD K MONTÁŽI

Vnější roh s částečně rovným čelem

– Rohy jsou zaříznuté pod úhlem 45°.

– Úhel v rohu panelu je seříznut tak, aby vznikla malá (cca

2 mm) rovná čelní plocha.

– Výhoda spoje je, že není tak ostrý a drobné nepřesnosti

jsou mnohem méně patrné.

Vnější roh s částečně rovným čelem a lištou v líci

– Rohy jsou zaříznuté pod úhlem 45°.

– Mezi jednotlivými panely je lišta, která vyrovnává

nerovnosti a tvoří bezpečný roh bez ostrých hran.

Vnější roh s lištou v líci

– Spoj je nutné provést co možná nejpřesněji, jsou

povoleny minimální odchylky v rovinnosti podkladu.

– U tohoto spoje je kladen důraz na přesnost a preciznost

provedení.

Vnitřní roh s přiznanou spárou

– Nejjednodušší provedení vnitřního spoje, optimální

spára je 4–8 mm

Vniřní roh s částečným zkosením

– Tento spoj je náročnější na přesnost a provedení, je

efektivní.

Vnitřní roh s rohovým hranolkem

– Tento spoj se provádí tak, že se do rohu před montáží

akustických desek vloží hranol se sešikmenou hranou a

akustické desky jsou ukončeny těsně u hranolu, nebo je

možné nechat mezi hranolem a deskou přiznanou spáru

3–4 mm.

ODSAZENÍ cca 4-8 mm

Page 30: NOVATOP ACOUSTIC

30 www.novatop-system.cz

NOVATOP ACOUSTIC

NÁVOD K MONTÁŽI

Svislé konstrukce

– Vzhledem k možným nerovnostem podlah, sesedání

a jiných okolností, které ovlivňují montáž, doporučujeme

ukončit akustický panel kousek nad podlahou a vytvořit

detail s přiznanou spárou nebo spáru překrýt lištou

viz obrázky.

Detail ukončení s lištou

Detail ukončení akustického panelu 50 mm nad podlahou

Doporučené aplikace

Aplikace na vodorovné a svislé konstrukce

– Rodinné domy, byty

– Posluchárny a přednáškové sály

– Kanceláře

– Autosalony

– Koncertní sály

– Školská zařízení

– Sportovní haly a tělocvičny

– Sakrální stavby

Návaznost stropních a stěnových panelů

Detail ukončení s lištou

Detail ukončení s přiznanou spárou

UKONČENÍ AKUSTICKÝCH PANELŮ

Vodorovné konstrukce

– Doporučujeme ukončit akustický panel přiznanou

spárou nebo překrýt lištou.

Detail ukončení s lištou

Detail ukončení s přiznanou spárou

STĚNA

PODLAHA

ROH DESEK PŘEKRYTÝ LIŠTOU

STROP

STĚNA

5-15 mm

STROP

STĚNA

STĚN

A

PODLAHA

STROP

STĚNA

SPÁRA4 - 8 mm

STROP

STĚNAROHOVÝ SPOJ DESEK PŘEKRYTÝ LIŠTOU

12

13

11

Page 31: NOVATOP ACOUSTIC

31www.novatop-system.cz

ZPRACOVÁNÍ, BALENÍ, SKLADOVÁNÍ,

PŘEPRAVA, MANIPULACE

ZPRACOVÁNÍ

Panely NOVATOP ACOUSTIC jsou zpracovány z lamel z masivního rostlého dřeva (SWP). Lamely v každé vrstvě jsou slepeny

v podélném i příčném směru a vrstvy jsou slepeny mezi sebou. Kvalita broušení odpovídá zrnitosti 100. Vlhkost při expedici

činí 10 % ± 3 %. Veškeré opracování se provádí na CNC strojích.

Upozornění: Vlastnosti dřeva jsou u tohoto výrobku zachovány, a proto reaguje na změny teplot a vlhkosti sesycháním

popř. bobtnáním. Špatným skladováním a použitím v extrémních podmínkách (extr. teploty a vlhkost) může docházet

k tvorbě trhlin a deformacím.

BALENÍ

Po konečné kontrole kvality se panely kompletují do balíků, balí do PE folie (ochrana proti změnám vlhkosti, znečištění

a částečně i mechanickému poškození) a po obvodu napříč stahují balící páskou. Každý balík je opatřen identifi kačním

štítkem s popisem. Štítky jsou umístěny na dolní levé, podélné straně paketu.

Štítek na balík

SKLADOVÁNÍ

Akustické panely musí být skladovány v uzavřených, suchých prostorách a uložené vodorovně. Po odstranění ochranného

obalu musí být pečlivě přikryté, nejlépe jiným plošným materiálem. Akustické panely je nutné chránit proti dešti a tekoucí

vodě. Pro ochranu před vodou, nečistotami a nadměrným slunečným zářením doporučujeme použít nepromokavé plachty.

Pohledové plochy panelů je nutno udržovat v čistotě, nedoporučujeme po pohledových plochách šlapat. Na pakety

akustických panelů nepokládáme jiný materiál ani břemena.

PŘEPRAVA

Standardně jsou panely přepravovány v kamionech (krytých návěsech), případně v kontejnerech.

Upozornění: Panely musí být po celou dobu chráněny proti nepříznivým povětrnostním vlivům. Během delší přepravy za

nepříznivých klimatických podmínek může u panelů dojít ke změně vlhkosti, doporučujeme jejich aklimatizace před dalším

zpracováním (postupné vysoušení, postupné změny teplot).

MANIPULACE

Při manipulaci je nutné dbát na ochranu obalového materiálu, ploch a hran panelů, aby nedošlo k jejich poškození. Akustické

panely musí být po celou dobu chráněny proti nepříznivým povětrnostním vlivům.

Upozornění: Za poškození výrobku, způsobené nevhodným skladováním, opracováním, nevhodným použitím nebo

nedodržením pracovních postupů při montáži, nepřebírá výrobce žádné záruky.

Výrobce: AGROP NOVA a.s., Ptenský Dvorek 99, Ptení, Czech Republic, www.novatop-system.cz

ZÁKAZNÍK: OBJEKT: ADRESA DODÁNÍ: POPIS: NT AC Marilyne 8/25 ČÍSLA POZIC:

POČET KS: xx DATUM: HMOTNOST: cca kg ROZMĚR: mm KONTROLA:

BALÍK č. 1 1020 - CPD - 070044225NB1020

AGROP NOVA12

ETA-12/0079

Page 32: NOVATOP ACOUSTIC

www.novatop-system.cz

Technická dokumentace a certifi káty ke stažení na www.novatop-system.cz

Certifi káty výrobce:Výrobce: AGROP NOVA a.s.

Ptenský Dvorek 99

798 43 Ptení

Česká republika

tel.: +420 582 397 857

[email protected]

novatop-system.cz

novatopcz

EVROPSKÁ UNIE EVROPSKÝ FOND

PRO REGIONÁLNÍ ROZVOJ

INVESTICE DO VAŠÍ BUDOUCNOSTI