1
Novel Coronavirus (SARS-CoV-2) Fast Nucleic Acid Detection Kit (PCR-Fluorescence Probing) Whole process only in 40 minutes Contains all components from collection to detection Non-cold chain to minimize the cooling cost Product Characteristics Detection Process Product Performance Index Immediately detectable: It’s easy to operate, without extraction, and only needs a fluorescence quantitative PCR instrument, The number of samples in a single test can be adjusted flexibly according to the number of people to be tested, which is extremely suitable for epidemic screening in communities, stations, airports, customs, supermarkets, schools and other areas. High sensitivity: The minimum detection limit can be as low as 300 copies / ml. Fast: Complete the whole process from sampling to detection in 40 minutes. Transportation at room temperature : The kit can be stored at room temperature and non-cold chain to minimize the cooling cost. Package Detection Methods Detect genes Sample Requirements Instrument Compatibility Sensitivity Precision Storage Condition Valid Period Minimum detection limit: 300 copies / ml The coefficient of variation (CV ,%) of the precision Ct value within the batch was ≤5%. Stored at room temperature,before the kit is opened and used. 12 months 48 tests /box PCR-Fluorescence Probing (direct amplification) ORF1abN Pharyngeal swab ABI 7500, Biorad CFX96 and Any RT-PCR instruments with minimal FAM, ROX and VIC Channel. 1. Collect the sample with a pharyngeal swab 2. Put the head of swab into the virus sampling tube, shake it up and down and mix well 4. Put tube into the qPCR instrument for detection and determination of the result 3. Take the mixed liquid and add it to the reaction amplification tube There is no cross-reactivity with positive samples such as coronavirus (NL63, HKU1, 229E, OC43), MERS-coronavirus,SARS-coronavirus,influenza A virus, influenza B virus Yamagata type, etc. The negative control of the testing enterprises were all negative. Specificity CoWin Biosciences Co., Ltd Acquired certification www.cwbiosciences.com [email protected]

Novel Coronavirus (SARS-CoV-2) Fast Nucleic Acid Detection

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Novel Coronavirus (SARS-CoV-2) Fast Nucleic Acid Detection

Novel Coronavirus (SARS-CoV-2) Fast Nucleic Acid Detection Kit (PCR-Fluorescence Probing)

Whole process only in 40 minutes

Contains all components from collection to detectionNon-cold chain to minimize the cooling cost

Product Characteristics

Detection Process

Product Performance Index

● Immediately detectable: It’s easy to operate, without extraction, and only needs a fluorescence quantitative PCR instrument, The number of samples in a single test can be adjusted flexibly according to the number of people to be tested, which is extremely suitable for epidemic screening in communities, stations, airports, customs, supermarkets, schools and other areas.● High sensitivity: The minimum detection limit can be as low as 300 copies / ml.● Fast: Complete the whole process from sampling to detection in 40 minutes.● Transportation at room temperature : The kit can be stored at room temperature and non-cold chain to minimize the cooling cost.

Package

Detection Methods

Detect genes

Sample Requirements

Instrument Compatibility

Sensitivity

Precision

Storage Condition

Valid Period

Minimum detection limit: 300 copies / ml

The coefficient of variation (CV,%) of the precision Ct value within the batch was ≤5%.

Stored at room temperature,before the kit is opened and used.

12 months

48 tests /box

PCR-Fluorescence Probing (direct amplification)

ORF1ab,N

Pharyngeal swab

ABI 7500, Biorad CFX96 and Any RT-PCR instruments with minimal FAM, ROX and VIC Channel.

1. Collect the samplewith a pharyngeal

swab

2. Put the head of swab into the virus sampling tube, shake it up

and down and mix well

4. Put tube into the qPCRinstrument for detection anddetermination of the result

3. Take the mixed liquidand add it to the reaction

amplification tube

There is no cross-reactivity with positive samples such as coronavirus (NL63, HKU1, 229E, OC43), MERS-coronavirus,SARS-coronavirus,influenza A virus, influenza B virus Yamagata type, etc. The negative control of the testing enterprises were all negative.

Specificity

CoWin Biosciences Co., Ltd

Acquired certification

www.cwbiosciences.com [email protected]