37
NPB-42

NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL [email protected] REAL PEOPLE Courteous

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

DWYER INSTRUMENTS, INC.

P.O. Box 373Michigan City, IN 46360

Return Service Requested

©Copyright 2013 Dwyer Instruments, Inc. 3/13

Printed in U.S.A.

NPB-42

TO ORDER:Phone: 219/879-8000

Fax: 219/872-9057 www.dwyer-inst.com

Page 2: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

INTERNATIONAL CUSTOMERSDwyer has local distributors in over 50 countries. Contact the office of your country or contact the corporate headquarters to

find your local distributor. You can also go to our website at the following address to be contacted by your local distributor:

http://www.dwyer-inst.com/Distributors/DistContactInfo.cfm.

Corporate Headquarters

DWYER INSTRUMENTS, INC.102 Indiana Highway 212,

P.O. Box 373

Michigan City, IN 46360, U.S.A.

PHONE FAX

219/879-8000 219/872-9057

United Kingdom

DWYER INSTRUMENTS LTDUnit 16, The Wye Estate, London Road

High Wycombe, Bucks HP11 1LH-U.K.

PHONE FAX

(+44) (0) 1494 461707 (+44) (0) 1494 465102

Australia

DWYER INSTRUMENTS, PTY. LTD.Unit 1, 11 Waverley Drive

Unanderra, NSW 2526 Australia

PHONE FAX

(+61) (0) 2 4272 2055 (+61) (0) 2 4272 4055

Hong Kong

DWYER INSTRUMENTS HK, LTD.Unit 605A, 6/F, Shui Hing Centre

13 Sheung Yuet Road, Kowloon Bay, Hong Kong

PHONE FAX

+852-23181007 +852-27561565

TECHNICAL SUPPORT

[email protected]

LITERATURE REQUESTS

[email protected]

QUOTATION/BID RE-

QUESTS

[email protected]

GENERAL INFORMATION

[email protected]

PHONEIn the U.S. call toll free:

800/872-9141

Outside the U.S. call:

219/879-8000

FAX219/872-9057

[email protected]

WEBSITEwww.dwyer-inst.com Dwyer Instruments, Inc. - Standard Terms and Conditions of Sale

1. Prices and Specifications are subject to change without notice.

2. Shipping dates are approximate. They are dependent upon credit approval and subject to delays beyond our control.

3. Terms: Net 30 days to companies with established credit rating. In the event Buyer fails to fulfill previous terms of payment, orin case Seller shall have any doubt at any time as to Buyer’s financial responsibility, Seller may decline to make further deliveriesexcept upon receipt of cash in advance or other special arrangements.

4. Liability Point and Title: All material is sold EXW Ex Works Dwyer Instruments, Inc. Title to all material sold shall pass to buyerupon delivery by Seller to carrier at shipping point.

5. State and Local Taxes: Any taxes which the Seller may be required to pay or collect upon or with respect to the sale, purchase,delivery, use or consumption of any of the material covered hereby shall be for the account of the Buyer and shall be added to thepurchase price.

6. Special tooling, dies, silk screens and molds acquired specially to produce goods for Buyer remain the property of Dwyer In-struments, Inc., and may not be removed. They will be maintained in good condition for a minimum period of three years from thedate of the original purchase order.

7. Export Orders: Terms, discounts and conditions of sale for purchase orders originating or for shipment to final destinations out-side the U.S.A. will be furnished upon request.

8. Limited Warranty: The Seller warrants all Dwyer instruments and equipment to be free from defects in workmanship or mate-rial under normal use and service for a period of one year from date of shipment. Liability under this warranty is limited to repair orreplacement EXW Ex Works Dwyer Instruments, Inc of any parts which prove to be defective within that time or repayment of thepurchase price at the Seller’s option provided the instruments have been returned, transportation prepaid, within one year from dateof purchase. All technical advice, recommendations and services are based on technical data and information which the Seller be-lieves to be reliable and are intended for use by persons having skill and knowledge of the business, at their own discretion. In nocase is Seller liable beyond replacement of equipment EXW Ex Works Dwyer Instruments, Inc or the full purchase price. This war-ranty does not apply if the maximum ratings label is removed or if the instrument or equipment is abused, altered, used at ratingsabove the maximum specified, or otherwise misused in any way.

THIS EXPRESS LIMITED WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER REPRESENTATIONS MADE BY ADVER-TISEMENTS OR BY AGENTS AND ALL OTHER WARRANTIES, BOTH EXPRESS AND IMPLIED. THERE ARE NO IMPLIEDWARRANTIES OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE FOR GOODS COVERED HEREUN-DER.

9. Buyer’s Remedies: THE BUYER’S EXCLUSIVE AND SOLE REMEDY ON ACCOUNT OF OR IN RESPECT TO THE FUR-NISHING OF NON-CONFORMING OR DEFECTIVE MATERIAL SHALL BE TO SECURE REPLACEMENT THEREOF AS AFORE-SAID. THE SELLER SHALL NOT IN ANY EVENT BE LIABLE FOR THE COST OF ANY LABOR EXPENDED ON ANY SUCHMATERIAL OR FOR ANY SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES TO ANYONE BY REA-SON OF THE FACT THAT IT SHALL HAVE BEEN NON-CONFORMING OR DEFECTIVE.

10. Acceptance: All orders shall be subject to the terms and conditions contained or referred to in the Seller’s quotation, ac-knowledgment, and to those listed here and to no others whatsoever. No waiver, alteration or modification of these terms and con-ditions shall be binding unless in writing and signed by an executive officer of the Seller. All orders are subject to written acceptanceby Dwyer Instruments, Inc., Michigan City, Indiana, U.S.A.

NOTE:

Each item (model, range, part number, etc.) is discountedindependently. In an order for more than one item, differ-ent items cannot be combined to earn a greater discount.

Most items are subject to STANDARD schedule at right.

Prices followed by the symbol b are subject to discountsper schedule B.

Certain items such as repairs, repair parts, EXPL and WP

housings, prices followed by the symbol n, special scaleand tag charges are priced at net and earn no discount.

INDUSTRIAL DISCOUNT SCHEDULE*

QUANTITYOF EACH

ITEM

1-24

25-99

100-249

250-499

500-Up

Net

5%

10%

15%

20%

Net

Net

5%

10%

15%

DISCOUNTS

STANDARD SCHEDULE B

*Please contact us for discount schedules for other account types.

Dwyer Instruments, Inc. - Discount Schedule

Page 3: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

1

At Dwyer it all starts with innovative products designed according to the needs of our customers. We strive to make products optimized

for ease of use, dependability and manufacturability. Through our over 75 years of manufacturing excellence, Dwyer has found the

means to manufacture products cost effectively to offer the best value to our customers. We supply the highest quality products and

stand behind them. Dwyer products are trusted in applications all over the world in almost every industry.

Dwyer Instruments, Inc. produces a broad range of competitively priced precision instruments for measuring, transmitting and

controlling pressure, temperature, level and flow.

Many of these instruments are widely known by their individual brand names, such as Magnehelic® and Spirahelic® pressure gages,

Photohelic® switch/gages, Rate-Master®, Mini-Master® and Visi-Float® flowmeters, Slack Tube® and Flex-Tube® manometers, and

Dwyer® pressure switches.

Other established Dwyer brands, including Flotect® flow and level switches, Hi-Flow® valves, Self-Tune temperature controllers and

Iso Verter® signal converters/isolators, are the products of companies that are now divisions of Dwyer Instruments – Mercoid, W. E.

Anderson, Proximity Controls and Love Controls.

Founded in 1931, Dwyer Instruments, Inc. moved its manufacturing and headquarters from Chicago, Illinois, in 1955, to newly

constructed, greatly-expanded facilities in Michigan City, Indiana. The company has since added three more Indiana facilities in

Wakarusa, Kingsbury and Wolcott as well as manufacturing facilities in Anaheim, California; Fergus Falls, Minnesota; and Kansas

City, Missouri.

In addition to making and selling quality precision instruments, Dwyer Instruments, Inc. is committed to a standard of customer

service, including competitive prices and knowledgeable, courteous technical support, that generates and sustains long-term

relationships.

Dwyer Instruments, Inc.

CALL TO ORDER | 800/872-9141

Page 4: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

DWYER INSTRUMENTS, INC. | www.dwyer-inst.com2

TO CONTACT A TECHNICAL SUPPORT ENGINEER

PHONE

219/879-8000

FAX

219/872-9057

EMAIL

[email protected]

REAL PEOPLE

Courteous and professional customer service representatives are

available via phone and email to process and provide assistance with your

order. Dwyer provides industry leading response time to answer your call

quickly without making you wait.

PRICING

Contact us for formal quotes, Dwyer offers bids and project quotes.

Discounts are available for particular customer types based on quantities

purchased.

LARGE INVENTORY LOCATED CENTRALLY IN THE U.S.

Dwyer is committed to get you your order quickly with more than 5,000

line items in stock in our Michigan City, Indiana headquarters and in most

cases lead times less than two weeks for non-stock products.

FAST PROCESSING AND PACKING

Our dedicated shipping staff packs and ships your order the same day on

stock items ordered before 2:00 PM U.S. Central Time.

FLEXIBLE SHIPPING

Dwyer offers blanket orders for OEM’s to schedule out your product

shipments to be when you need them. Contact us for details.

• Product Selection

• Application Assistance

• Regulatory and Agency Approval

Compliance

• Installation Guidance

• Maintenance and Repair

• Product Customization for OEM’s

All of our technical sales staff are degreed engineers trained to be product

and industry experts. We listen to your needs and get you the answers

you want quickly.

WE HELP YOU FIND A SOLUTION

Page 5: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

3CALL TO ORDER | 800/872-9141

DWYER DIGITAL CATALOG

• Browse the catalog on the web or download to your

computer to have access to it when offline

• Search by any word or phrase in the catalog

• Print or email pages

• Add notes to any page

DWYER CATALOG APP

• Available on iOS® and Google Play® Markets

• Designed for iPad®, iPhone®, and Android® mobile devices

• Download the catalog to your mobile device and view it

anytime when offline

• Search by word or phrase

• Thumbnail page navigation

PRODUCT INFORMATION

• We offer more than what is in the Dwyer catalog – more

products, more options and more technical details

• Instruction manuals and catalog pages in PDF format for

easy viewing and download

• Product dimensions viewable in web browser

• Product drawings in DWG format for downloading and

using in CAD software

• Agency approval certificates – CE, FM, UL, CSA and

ATEX

• Product price and lead time

• Product country of origin

PRODUCT SEARCH

• Search by model number, keyword or series

PRODUCT CONFIGURATOR

• Create and order your own custom Dwyer product on

the web

• Easy to use graphic interface lets you see all available

options and select what you need for your application

• Shows option rules so that you can see what options are

not compatible

VIDEO LIBRARY

• A collection of informative and instructional videos that

are centered on a given product series

• Search videos according to product category

• Link to product page for further information

AND MORE!

• Product applications and technical guides

• Download product brochures and catalogs in PDF format

• Frequently asked questions

• Industry articles

Page 6: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

DWYER INSTRUMENTS, INC. | www.dwyer-inst.com4

Ne

w P

rod

uc

ts Backflow Prevention Test KitTest Flow in Hydronic Systems

The Model BTK2 Backflow Prevention Test Kit is capable of testing hydronic systemswith test procedures recommended by ASSE, AWWA, CSA, FCCC, HR-USV, and NEWWA.The BTK2 is comprised of three valves and is specially designed for testing backflow preventionassemblies. The tests can be completed in almost any area by mounting the unit with theincluded high performance elastic cord. PTFE-lined brass ball valves simplify the adjustmentprocedure. The large, easy-to-grip needle valve allows for quick adjustment. The kit includes a4.5˝ diameter diaphragm differential pressure gage (0 to 15 psid), a 1.5˝ diameter in-linepressure gage (0 to 200 psig), three 3´long hoses (color-coded), three sets of brass adapterfittings for hookups to all standard size test cocks, an elastic cord for hanging/mounting, and adurable polyethylene carrying case.

ModelBTK2

SPECIFICATIONS

Pressure Limits: 175 psi (12 bar).

Temperature Limits: 210°F (99°C).

Range: 4.5˝ gage: 0 to 15 psid (0 to 1 bar); 1.5˝ gage: 0 to 200 psi (0 to 14 bar).

Accuracy: 4.5˝ gage: ±2% FS; 1.5˝ gage: ±3-2-3% FS.

Wetted Parts:

4.5˝ Gage: Anodized aluminum;

4.5˝ Gage Diaphragm: Buna-N;

1.5˝ Gage: Brass;

Ball Valves: PTFE lined brass;

Needle Valve: Brass;

Hose Couplings: Brass;

Adaptors: Brass;

Hose: Rubber.

Size: Case: 9˝ H x 16˝ W x 9˝ D (228 mm H x 406 mm W x 228 mm D).

Weight: 8.9 lb (4 kg).

Ø4-25/32[Ø121.36]Ø1-41/64

[Ø41.66]

5-31/64[139.46]

2[50.80]

3[76.12]

9-39/64[244.27]

7-7/16[189.07]

The Series TPT Pressure Transmitter is the ideal choice for all types of industrial pressureapplications. Machined from a solid piece of 17-4PH SS, the TPT provides a leak proof, all metalsystem without O-rings, welds, or organics exposed to the pressure media. Its design allows forstable operation when subject to shock and vibration. Utilizing piezoresistive technology withdigital compensation and temperature correction, the TPT gives high accuracy and stabilityunder harsh environmental conditions. Available in ratiometric and 4 to 20 mA outputs.

Industrial Pressure Transmitter17-4PH SS Wetted Parts, Packard Electrical Connection

3-3/8[85.88]

31/64[12.15]

35/64[13.72]

7/8[22.23]

SPECIFICATIONS

Service: Compatible liquids and

gases.

Wetted Materials: 17-4PH SS.

Accuracy: ±1% FS (RMS).

Stability: < ±0.25% FS per year.

Temperature Limits: -13° to 185°F

(-20° to 85°C).

Compensated Temperature Range:

-13° to 185°F (-20 to 85°C).

Pressure Limits: Proof pressure: 2 x

FS; Burst pressure: 3 x FS.

Thermal Effect:

Zero shift: ±0.01% FS per 1°C;

Span error: ±0.02% FS per 1°C.

Power Requirements: See table.

Output Signal: See table.

Loop Resistance: < 100 Ω.

Electrical Connection: Packard

connector.

Process Connections: 1/4˝-18 male

NPT.

Shock: ±20 g.

Vibration: 50 g @ 20 to 2000 Hz.

Weight: 0.20 lb (0.09 kg).

Model

TPT-R01

TPT-R02

TPT-R03

TPT-R04

TPT-R05

TPT-R06

TPT-C01

TPT-C02

TPT-C03

TPT-C04

TPT-C05

SeriesTPT

Range psi (bar)

100 (6.89)

250 (17.24)

500 (34.47)

1000 (68.95)

2500 (172.37)

5000 (344.74)

100 (6.89)

250 (17.24)

500 (34.47)

1000 (68.95)

2500 (172.37)

Power Requirements (VDC)

4.75 to 5.25

4.75 to 5.25

4.75 to 5.25

4.75 to 5.25

4.75 to 5.25

4.75 to 5.25

9 to 30

9 to 30

9 to 30

9 to 30

9 to 30

3´ HOSE WITH FEMALE COUPLINGS[SHOWN UNATTACHED]

FEATURES

• Robust construction to withstand high vibration

• 17-4PH SS wetted material

• Standard packard connector

APPLICATIONS

• Process automation and control

• Test and measurement equipment

• Factory automation

• Energy management

NPB-42

b Items are subject to Schedule B discounts.

Model BTK2, Backflow Prevention Test Kit . . . . . . . . . . . . . . . . . . . . . . . . . .$938.00b

Includes: 3 valve assembly, 4.5˝ differential pressure gage (attached), 1.5˝ in-line

pressure gage (attached), three 3´ hoses, three sets of brass adapter fittings, bungee

cord, plumbers tape, polyethylene carrying case.

Output Signal

0.5 to 4.5 VDC

0.5 to 4.5 VDC

0.5 to 4.5 VDC

0.5 to 4.5 VDC

0.5 to 4.5 VDC

0.5 to 4.5 VDC

4 to 20 mA

4 to 20 mA

4 to 20 mA

4 to 20 mA

4 to 20 mA

Price

$109.00 list

109.00 list

109.00 list

109.00 list

109.00 list

109.00 list

109.00 list

109.00 list

109.00 list

109.00 list

109.00 list

Page 7: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

5

Ne

w P

rod

uc

ts

Ideal for use with our precision air velocity gages, transmitters and digital test

instruments, the Series 160F Pitot Tubes are constructed from corrosion resistant

stainless steel for a lifetime of service. Permanent, stamped insertion depth

graduations on sides of the 160F Pitot facilitate accurate positioning. Static pressure

port is parallel to sensing tube allowing quick, easy alignment of tube with the air flow.

Straight design allows for easy insertion into ducts through grills and pressure taps

as well as aids in positioning in hard to reach locations where a hook style Pitot tube

may not allow access.

Model160F Straight Stainless Steel Pitot Tubes

SPECIFICATIONS

Wetted Material: 304 SS.

Accuracy: ±2% FS, 0 to 9000 FPM (45 M/s).

K-Factor: 0.81.

Temperature Limit: 1500°F (815°C).

Insertion Length: 18˝ (44 cm).

Process Connections: 1/4˝ OD.

Weight: 4.3 oz (122 g).

Sensing Profile

ModelAAFS

SPECIFICATIONS

Service: Air and compatible gas.

Wetted Materials:

Vane: SS; Lever: Brass; Base: Galvanized steel.

Housing: ABS.

Temperature Limits:

Ambient: -40 to 180°F (-40 to 85°C);

Process: -14 to 185°F (-10 to 85°C).

Humidity Limits: 10 to 90%, non-condensing.

Switch Type: SPDT.

Electrical Rating: 15(8) A @ 250 VAC.

Electrical Connection: Screw terminal with M18 x 1.5 cable gland.

Process Connection: Flange.

Mounting Orientation: Horizontal duct flow.

Set Point: Internal screw.

Enclosure Rating: IP65.

Weight: 13.6 oz (380 g).

The Model AAFS Adjustable Air Flow Switch is capable of detecting a wide range ofair velocities with minimal user calibration. The adjustable screw changes the set point atwhich the SPDT snap switch engages. Quality features include a stainless steel vane,galvanized steel base, and ABS enclosure. The unit is field adjustable from 200 to 1800FPM (1 to 9.2 m/sec).

ADJUSTMENTSCREW

GROUND SHIELDEDTERMINALBLOCK

5.94[151.00]

2.81[71.50]

M18X1.5PROCESS

CONNECTION

3.86[98.00]

4.92[125.00]

3.15[80.00]

1.02[26.00]

4.15[105.50]

2.56[65.00]

2.81[71.50]

0.49[12.50]

6.89[175.00]

3.86[98.00]

3.03[77.00]

4.02[102.00]3.46

[88.00]

2.56[65.00]

2.52[64.00]

Ø0.20[Ø5.00]

Adjustable Air Flow Paddle SwitchRanges from 200 to 1800 FPM, Stainless Steel Vane, ABS Housing

n Items are net priced and are not subject to any discount.

CALL TO ORDER | 800/872-9141

NPB-42

Model 160F, Straight Stainless Steel Pitot Tube . . . . . . . . . . . . . . . . . . . .$150.00

Model AAFS, Adjustable Air Flow Paddle Switch . . . . . . . . . . . . . . . . . . . . .$68.00

ACCESSORIES

A-156, Flange Mounting Plate 1/2˝ female NPT . . . . . . . . . . . . . . . . . . . . . .$15.50

A-158, Split Flange . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13.75

A-159, Mounting Gland . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28.00

A-397, Step Drill . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33.75n

Page 8: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

DWYER INSTRUMENTS, INC. | www.dwyer-inst.com6

SeriesCDTR Carbon Dioxide/RH/Temperature Transmitter

NDIR CO2 Sensor, Universal CO2/RH Outputs, Optional Relay

Series CDTR Carbon Dioxide, Relative Humidity and Temperature Transmitters

reduce the number of sensors mounted on a wall or in a duct. By combining CO2, RH, andtemperature in one device, system integrators are able to lower installation time ofmounting multiple housings, while lowering material cost at the same time. Even with thethree sensors combined into a single unit, replacement cost is not increased due to thepluggable nature of the humidity sensor, which allows it or the temperature to be replacedat a fraction of the cost of a new CO2 transmitter.

Like our popular Series CDT Carbon Dioxide Transmitter, a single-beam dual-wavelengthnon-dispersive infrared (NDIR) sensor is used to automatically correct the measurement inboth occupied* and unoccupied buildings against light source aging effects. The single-beamdual-wavelength sensor technology provides a higher level of accuracy compared toAutomatic Baseline Correction methods which can unintentionally shift the calibrationbased on CO2 levels and barometric pressure conditions. In order to achieve the bestpossible accuracy, the Series CDTR also includes digital barometric pressure adjustmentand the ability to field-calibrate the sensor.

Universal outputs for both carbon dioxide and relative humidity allow users to select thetransmitter output to be 4 to 20 mA, 0 to 5 VDC, or 0 to 10 VDC to work with virtually anybuilding management controller. Additionally, passive thermistor or RTD sensor can beordered for a temperature output. An optional relay for the carbon dioxide measurementcan be used to control exhaust fans, open actuated windows or dampers, or signal a lightor horn.

For applications that require visual indication, the wall mount configurations of the SeriesCDTR can be ordered with an integral LCD display. When ordering a duct mountconfiguration or a wall mount configuration without the display, the Model A-449 remoteLCD display can plug into the miniature connector port on the transmitter. The displaycan be configured to display temperature only, relative humidity only, CO2 only, CO2 andhumidity, or CO2 and temperature. Push buttons are standard on all configurations of thetransmitters for access to the menu structure, but wall mount configurations can be orderedwithout the buttons. To prevent tampering, the action of the buttons can be locked out usingan internal jumper selection. Menu items that can be accessed via the push buttons include:engineering units, relay output set points, display configuration, transmitter output scaling,ambient barometric pressure, and field calibration of the transmitter.

*For buildings occupied 24 hours per day, it is recommended that calibration be

verified every 6 to 12 months depending on application.

SPECIfICATIONS

Range:

CO2: 0 to 2000 or 0 to 5000 ppm

(depending on model);

Relative Humidity: 0 to 100% ;

Temperature: 32 to 122°F (0 to 50°C).

Accuracy: ±40 ppm + 3% of reading

(CO2); ±2% (RH).

Temperature Dependence: ±8 ppm /

°C at 1100 ppm.

Non-Linearity: 16 ppm.

Pressure Dependence: 0.13% of

reading per mm of Hg.

Response Time: 2 minutes for 99%

step change.

Temperature Limits: 32 to 122°F (0 to

50°C).

Humidity Limits: 10 to 95% RH (non-

condensing).

Power Requirements: 16 to 35 VDC /

19 to 28 VAC.

Power Consumption: Average: 2

watts; Peak: 3.75 watts.

Sensor: Single-beam, dual-wavelength

NDIR.

Output:

Current: 4 to 20 mA (max 500 Ω);

Voltage: 0 to 5 VDC or 0 to 10 VDC

(min 500 Ω);

Relay: SPST NO 2A @ 30 VDC;

RTD or thermistor per r-t curves

(depending on model).

Weight: 5.6 oz (158.8 g).

Agency Approvals: CE (duct mount

only).

Series

Range

Configuration

CO2 Output

Temperature

Output

RH Output

Options

4-31/64[113.9]

3-13/32[86.52]

35/64[13.89]

1-13/32[35.72]

1-53/64[46.43]

3x 3/8[9.53]

1-13/32[50.01]

1-3/16[30.20]

1-3/16[30.20]

7/8[22.35]

4x 3/16[4.76]

CDTR- 2

2

5

W

W

D

A

0

A

B

C

D

E

F

-LCD

-LCD

-RLY

-NBC

4

4

1/8˝[3.175]

4-25/32˝[121.612]

4-9/32˝[108.912] 2-13/16˝

[71.238]

Ø3-5/16˝[84.074]

11-49/64˝[298.956]

1-15/64˝[31.411]

4

4

Ne

w P

rod

uc

tsNPB-42

b Items are subject to Schedule B discounts.

Example: CDTR-2W4A4-LCD

0 to 2000 ppm CO2 range

0 to 5000 ppm CO2 range

Wall

Duct

4 to 20 mA / 0 to (5 or 10) VDC

None

10 KΩ NTC thermistor type III

10 KΩ NTC thermistor type II

3 KΩ NTC thermistor

Pt100 Ω RTD

Pt1000 Ω RTD

20 KΩ NTC thermistor

4 to 20 mA / 0 to (5 or 10) VDC

LCD display (wall only)

Relay

No buttons (wall only)

Price

-

-

$225.00

245.00

-

-

+5.00

+5.00

+6.00

+6.00

+6.00

+5.00

-

+35.00

+10.00

-

ACCESSORIES

A-449, Remote LCD Display allows remote indication of select

Dwyer Wall Mount Transmitters for validation or certification

purposes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$50.00

GCK-200CO-2000CO2, Calibration Gas Kit includes a 99.99%

Nitrogen gas cylinder for calibrating the zero point, and a 200 PPM

CO / 2000 PPM CO2 gas cylinder for calibrating the span point on

Dwyer’s gas sensing transmitters . . . . . . . . . . . . . . . . . . .300.00b

Page 9: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

7

SPECIFICATIONS

Range: CO2: 0 to 2000 PPM;

Relative Humidity: 0 to 99%;

Active Temperature: 32 to 122°F

(0 to 50°C).

Accuracy:

CO2: ±30 PPM or 3% of reading,

whichever is greater;

RH: ± 2.5% (20 to 80% RH) / 3.5%

(<20% and >80%);

Active Temperature: ± 1.5°F @ 72°F

(0.8°C @ 22°C);

Thermistor: ± 1.9°F @ 60 to 95°F

(1°C @ 15 to 35°C).

Temperature Dependence: ±0.11%

FS per °F (0.2% per °C).

Pressure Dependence: 0.135% of

reading per mm Hg.

Response Time: Signal updates every

5 seconds.

Warm Up Time: < 2 min (operational),

10 min (max. accuracy).

Temperature Limits:

Ambient: 32 to 122°F (0 to 50°C);

Storage: -40 to 158°F (-40 to 70°C).

Power Requirements: 18 to 30 VAC

RMS 50/60 Hz.

Sensor:

CO2: Non-dispersive infrared

sensor (NDIR) with ABC logic;

RH: Capacitive polymer sensor;

Temperature: 10 kΩ NTC

thermistor.

Weight: 7.2 oz (204 g).

Agency Approvals: CE, RoHS.

The Series CDW2 Wall Mount Carbon Dioxide Transmitters monitor ambientcarbon dioxide conditions for variable air volume (VAV) on demand ventilation systems.Universal current/voltage temperature and humidity outputs are also available to reducethe number of instruments mounted on the wall. The Non-Dispersive Infrared (NDIR)sensor continuously updates the calibration through a proprietary logic feature whichlimits the amount of error due to drift. A duct mount and a heated outside air enclosureare available enabling the CDW2 to be used in different environments.

4-37/64[116.40]

1-1/16[27.11]

3-13/64[81.40]

2-23/64[60.06]

BACK COVER

COVER LOCKING HOLE

1-1/16[27.11]

3-13/64[81.40]

2-23/64[60.06]

BACK COVER

COVER LOCKING HOLE

3-13/32[86.41]3-1/4

[82.55]

1-3/16[30.10]

1-3/16[30.10]

FOR MODELSWITH LCD DISPLAY

FOR MODELSWITH LCD DISPLAY

Model

CDW2-2W4A0

CDW2-2W4A4

CDW2-2W4B0

CDW2-2W4B4

CDW2-2W4C0

CDW2-2W4C4

CDW2-2W4D0

CDW2-2W4D4

CDW2-2W4E0

CDW2-2W4E4

CDW2-2W4F0

CDW2-2W4F4

CDW2-2E4A0

CDW2-2E4A4

CDW2-2E4B0

CDW2-2E4B4

CDW2-2E4C0

CDW2-2E4C4

CDW2-2E4D0

CDW2-2E4D4

CDW2-2E4E0

CDW2-2E4E4

CDW2-2E4F0

CDW2-2E4F4

Temperature Output

10kΩ Type III Thermistor

10kΩ Type III Thermistor

10kΩ Type II Thermistor

10kΩ Type II Thermistor

3kΩ Thermistor

3kΩ Thermistor

Pt100 RTD

Pt100 RTD

Pt1000 RTD

Pt1000 RTD

20kΩ Thermistor

20kΩ Thermistor

10kΩ Type III Thermistor

10kΩ Type III Thermistor

10kΩ Type II Thermistor

10kΩ Type II Thermistor

3kΩ Thermistor

3kΩ Thermistor

Pt100 RTD

Pt100 RTD

Pt1000 RTD

Pt1000 RTD

20kΩ Thermistor

20kΩ Thermistor

Standard Wall Housing

European Style Housing

Series CDW2 Carbon Dioxide Transmitters

Monitors CO2, Temperature and Humidity, Optional LCD DisplayRoHS

For optional LCD display, add -LCD to the end of the model number.

(Example: CDW2-2W4A0-LCD)

Shown with Optional LCD Display

Ne

w P

rod

uc

ts

Standard Style European Style

CALL TO ORDER | 800/872-9141

NPB-42

RH Output

N/A

Universal Current/Voltage Output

N/A

Universal Current/Voltage Output

N/A

Universal Current/Voltage Output

N/A

Universal Current/Voltage Output

N/A

Universal Current/Voltage Output

N/A

Universal Current/Voltage Output

N/A

Universal Current/Voltage Output

N/A

Universal Current/Voltage Output

N/A

Universal Current/Voltage Output

N/A

Universal Current/Voltage Output

N/A

Universal Current/Voltage Output

N/A

Universal Current/Voltage Output

Price

$340.00

440.00

340.00

440.00

340.00

440.00

345.00

445.00

345.00

445.00

340.00

440.00

340.00

440.00

340.00

440.00

340.00

440.00

345.00

445.00

345.00

445.00

340.00

440.00

ACCESSORIES

Model 1508, Duct Mount Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$100.00n

Model 1552, Outside Air Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250.00n

OPTION

-LCD, Integral LCD Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$50.00

n Items are net priced and are not subject to any discount.

Page 10: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

DWYER INSTRUMENTS, INC. | www.dwyer-inst.com8

The Series FLMG Flanged Electromagnetic Flow Sensor is a flangedelectromagnetic flowmeter designed for use in 4 to 10” pipes in municipal or industrialwater and wastewater applications. The FLMG has no moving parts and requires lessfrequent maintenance in applications where debris or sand is in the flow. It’s speciallydesigned with electrodes that discourage fouling and requires little space between themeter and a pipe elbow. Rate and total indication are standard for both models. Theincluded 20-foot power cable provides pulse output for use with a variety of displays andcontrollers for remote reading, data logging, pulse-to-analog conversion, and telemetryapplications. This series also features backup battery power to provide auxiliary powerduring power failures.

ACCESSORIES

• Series BAT, Blind Analog Transmitter, converts pulse output to 4 to 20 mA analog

output. Unit is loop powered, fits on the enclosure of the meter, and is field

spannable.

• Series RTI, Rate Total Indicator, converts pulse output to 4 to 20mA analog output

with local flow rate and totalization display. Unit is loop powered, fits on the

enclosure of the meter, and provides a high/low flow alarm.

• Series PWD, Pulse Divider, for use with pacing electronic metering pumps. Unit

divides the input frequency to any number from 1 to 9999 with the use of rotary

switches to suit a number of metering pump inputs.

Flanged Electromagnetic Flow SensorNo Moving Parts, Minimal Straight Pipe Requirement, Unobstructed Flow

3-61/64[100.46]

A

B C

D

SPECIFICATIONS

Service: Compatible non-coating

conductive liquids.

Range: See chart.

Wetted Materials:

Liner: Dual durometer rubber;

Electrodes: 316 SS.

Accuracy: ±1% (10% to 100% of FS

max. flow), ±2% (min. to 10% FS).

Temperature Limits: Process: 10 to

130°F (-12 to 54°C); Ambient: -40 to

158°F (-40 to 70°C).

Pressure Limits: 150 psi (10.3 bar).

Mounting Orientation: Horizontal or

vertical.

Process Connection: 150# drilling

ANSI flange.

Display: Rate: 5 digits; Total: 8 digits

LCD.

Output: Current sinking square wave

pulse, opto-isolated.

Power Requirements: 7 to 32 VDC @

30 mA and (2) 3.6 V AA lithium metal

batteries, installed and functional, user

replaceable for backup power.

Battery Life: 2 months with power

failure; 10 years with power.

Electrical Connection: #22 AWG, 3

conductor length (18´(5.5 m )

(2000´max.).

Conductivity: ≥20 microSiemens.

Empty Pipe Detection:

Hardware/software, conductivity-

based.

Enclosure Materials:

Body: Epoxy-coated welded steel;

Housing: Powder-coated diecast

aluminum;

Enclosure Rating: NEMA 4X (IP66).

Weight:

4˝: 32 lb (14515 g);

6˝: 47 lb (21319 g);

8˝: 69 lb (31298 g);

10˝: 125 lb (56699 g).

SeriesFLMG

Example

Series

Power/Size

Rate/Measurement

Total

Measurement

Pulse Rate

Options

GM

GM

LM

LS

FM

MH

GD

LD

04

04

06

08

10

FLMG

FLMG

GAL

GAL

GLX

LIT

LTX

MLT

CMT

CMX

CFT

CFX

H

H

1

2

4

15

15

30

45

60

DL

**20-foot (6 m) cable standard

*Units: Gal or Liter depending on (rate/total unit)

selection rate measurement

Minimum

Maximum

Gal/Min

12

500

Liter/Sec

.75

31.5

Gal/Min

32

1200

Liter/Sec

2

75.7

Gal/Min

60

2200

Liter/Sec

3.8

138.8

10˝

Gal/Min

95

3500

Liter/Sec

6

220.8

Dimension

FLMG-04-XX-XXX-X

FLMG-06-XX-XXX-X

FLMG-08-XX-XXX-X

FLMG-10-XX-XXX-X

A

Ø 3.12˝ (Ø 79 mm)

Ø 5.05˝ (Ø 128 mm)

Ø 6.44˝ (Ø 164 mm)

Ø 8.61˝ (Ø 219 mm)

B

9˝ (229 mm)

11˝ (279 mm)

13.5˝ (330 mm)

16˝ (406 mm)

C

7˝ (178 mm)

8.1˝ (206 mm)

9.1˝ (231 mm)

10.1˝ (257 mm)

D

10.24˝ (260 mm)

12.27˝ (312 mm)

14.24˝ (362 mm)

18.18˝ (462 mm)

Ne

w P

rod

uc

tsNPB-42

FLMG-04-GM-GAL-H-15

Flanged Electromagnetic Flow Sensor

DC Powered 4˝ Pipe

DC Powered 6˝ Pipe

DC Powered 8˝ Pipe

DC Powered 10˝ Pipe

Gallon/Minute

Liter/Minute

Liter/Second

Cubic Foot/Minute

Cubic Meter/Day

Million Gallon/Day

Mega Liter/Day

Gallon

Gallon x 1000

Liter

Liter x 1000

Mega Liter

Cubic Meter

Cubic Meter x 1000

Cubic Feet

Cubic Feet x 1000

High Frequency* Required with use with Series BAT

10 Units*/Pulse

100 Units*/Pulse

1000 Units*/Pulse

Factory-Installed Power/Output Cable, 15 m (50 ft)**

Factory-Installed Power/Output Cable, 30 m (100 ft)**

Factory-Installed Power/Output Cable, 45 m (150 ft)**

Factory-Installed Power/Output Cable, 60 m (200 ft)**

Internal Data Logger

Price

$1828.00b

+119.00b

+277.00b

+521.00b

+892.00b

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

+162.00b

+277.00b

+410.00b

+543.00b

+202.00bb Items are subject to Schedule B discounts.

Page 11: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

9

The Series IEFS Insertion Electromagnetic Flow Sensor comes in brass or stainlesssteel allowing it to handle a wide range of pressures and temperatures, as well as a varietyof available saddle fittings, Series SDF, to fit pipe sizes 3 to 24˝. The IEFS-1XX has anisolation valve which allows hot-tap installation. Additional options for this flow meterinclude adapter fittings and a reverse flow output. The Series IEFS is great for “dirty”water applications or any application where moving parts may be an issue.

PRINCIPLE OF OPERATION

The IEFS is a liquid flow meter that uses a magnetic field to measure flow. As

conductive fluids flow through the magnetic field, a voltage is generated which is

measured and translated into a pulse frequency output signal. This signal can then

be used with the Series BAT to produce a 4 to 20 mA analog signal, or the Series

RTI to display rate and total.

APPLICATIONS

• Conductive Liquids

• Municipal

• Industrial

• Irrigation

ACCESSORIES

• Series BAT, Blind Analog Transmitter, converts pulse output to 4 to 20 mA analog

output. Unit is loop powered, fits on the enclosure of the meter, and is field

spannable.

• Series RTI, Rate Total Indicator, converts pulse output to 4 to 20 mA analog output

with local flow rate and totalization display. Unit is loop powered, can fit on the

enclosure of the meter, and provides a high/low flow alarm.

• Series PWD, Pulse Divider, for use with pacing electronic metering pumps. Unit

divides the input frequency to any number from 1 to 9999 with the use of rotary

switches to suit a number of metering pump inputs.

1/2˝ CABLEGLAND

2-7/8[73.06]

2-3/4[69.70]

4[101.52]

4[101.42]

PHONE219-879-8000

FAX219-872-9057

WEBWWW.DWYER-INST.COM

MADE IN XXXXXX

SPECIFICATIONS

Service: Compatible clean or dirty non-coating, conductive liquids.

Range: 0.28 to 20 ft/s (0.08 to 6.09 m/s).

Wetted Materials:

Body Shaft/Fitting: 316 SS or brass;

Electrodes: Hastelloy®;

Electrode Cap: PVDF;

Valve Assembly: (IEFS-1XX) Bronze (SS optional) with bronze ball valve;

O-ring: EPDM.

Accuracy: ±1% FS.

Temperature Limits:

Process: 32 to 200°F (0 to 93°C);

Ambient: 0 to 160°F (-17 to 72°C).

Process Connection:

IEFS-0XX: 1-1/2˝ male NPT ;

IEFS-1XX: 2˝ male NPT.

Pressure Limit: 200 psi (13.8 bar).

Output: Current sinking, square wave pulse, opto-isolated, 550 Hz @ 20

ft/s, 30 VDC @ 6 mA max.

Power Requirements: 12 to 25 VDC @ 250 mA; Low Power: 12 to 25 VDC

@ 40 mA.

Electrical Connection: Terminal block.

Conductivity: ≥ 20 microSiemens/cm.

Enclosure Material: Housing: Die-cast powder-coated aluminum.

Enclosure Rating: NEMA 4X (IP66).

Weight:

IEFS-0SX: 6 lb (2721 g);

IEFS-0LB: 12 lb (5443 g);

IEFS-1XX: 15 lb (6804 g).

Example

Series IEFS

Size/Material

Options

IEFS

IEFS

0SB

0SB

0SS

0LB

0LS

1SB

1SS

1LB

1LS

BAF

BAF

SAF

SVA

NVA

RFO

BPT

SPT

IMM

LOP

EXT

Insertion Electromagnetic Flow SensorNo Moving Parts, Hot-Tap Option, 3 to 48˝ Field Adjustable Insertion

SeriesIEFS

Hastelloy® is a registered trademark of Hanes International

Hot-Tap Option(Shown installed on pipe)

Hot-Tap Option

*SS is stem and fitting. For SS valve order SVA option.

Ne

w P

rod

uc

ts

CALL TO ORDER | 800/872-9141

NPB-42

Price

$1212.00b

-

+250.00b

+201.00b

+382.00b

+266.00b

+472.00b

+557.00b

+780.00b

+57.00b

+76.50b

+689.00b

-90.00b

+172.00b

+38.25b

+54.50b

+175.00b

-

+349.00b

IEFS-0SB-BAF

Insertion Electromagnetic Flow Sensor

2˝ Brass Adapter Fittings (IEFS-0XX only)

2˝ SS Adapter Fittings (IEFS-0XX only)

316 SS Valve Assembly (IEFS-1XX only)

No Valve Assembly (deduct price) (IEFS-1XX only)

Reverse Flow Output

1-1/2˝ Brass BPT Adapter (2 piece) (IEFS-0XX only)

1-1/2˝ SS BPT Adapter (2 piece) (IEFS-0XX only)

Immersible (Urethane potted electrical components)

Low Power (12 to 25 VDC @ 40 mA)

12˝ Extension (IEFS-XLX only)

Hot-Tap

No Hot-Tap

No Hot-Tap

No Hot-Tap

No Hot-Tap

Hot-Tap

Hot-Tap

Hot-Tap

Hot-Tap

Size

3 to 10˝

3 to 10˝

10 to 48˝

10 to 48˝

3 to 10˝

3 to 10˝

10 to 48˝

10 to 48˝

Material

Brass

SS

Brass

SS

Brass

SS*

Brass

SS*

b Items are subject to Schedule B discounts.

Page 12: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

DWYER INSTRUMENTS, INC. | www.dwyer-inst.com10

The Series EFS2 Insertion Electromagnetic Flow Sensor is designed for pipe sizesfrom 1 to 12˝ and comes in three different materials (stainless steel, brass and PVC).There are a variety of custom fittings to choose from to ensure accurate fitting in the pipe.The Series EFS2 is useful for any applications where moving parts would be a problem,such as dirty liquids. It can handle applications where there are rapid changes in viscosityand flow. Other applications include small pipes and chemical metering pumps.

PRINCIPLE OF OPERATION

The EFS2 is a liquid flow meter that uses the conductivity of fluids to measure flow

rate. Liquid flow through its magnetic field produces a voltage that is measured and

translated into an output signal. It has a pulse frequency output which can be used

with the Series RTI to indicate flow rate and total, as well as the Series BAT signal

converter which provides an analog signal.

APPLICATIONS

• Industrial Process

• Chemical Metering Pumps

• Fertigation

ACCESSORIES

• Series BAT, Blind Analog Transmitter, converts pulse output to 4 to 20 mA analog

output. Unit is loop powered, fits on the enclosure of the meter, and is fields

spannable.

• Series RTI, Rate Total Indicator, converts pulse output to 4 to 20 mA analog output

with local flow rate and totalization display. Unit is loop powered, fits on the

enclosure of the meter, and provides a high/low flow alarm.

• Series PWD, Pulse Divider, for use with pacing electronic metering pumps. Unit

divides the input frequency to any number from 1 to 9999 with the use of rotary

switches to suit a number of metering pump inputs.

Insertion Electromagnetic Flow SensorNo Moving Parts, Durable, Easy Installation & Maintenance

4-15/16[125.30]

4[101.42]

3/32˝ THICK GASKET

2-3/4[69.90]

ELECTRODESO-RING

Ø1-37/64[40.13]

SENSOR BODY[STAINLESS STEEL,

BRASS OR PVC]3-9/32[83.45]

MODEL: EFS2-XX-XXX

SN: XXXXXXXXXX

SPECIFICATIONS

Service: Compatible clean or dirty non-coating, conductive liquids.

Range: 0.28 to 20 ft/s (0.08 to 6.09 m/s).

Wetted Materials:

Sensor: 316 SS, brass or PVC;

Electrodes: Hastelloy®, metal;

Electrode Cap: PVDF;

O-ring: EPDM (fluoroelastomer optional).

Accuracy: ±1% FS.

Temperature Limits:

Process: Brass/SS: 32 to 200°F (0 to 93°C); PVC: 32 to 130°F (0 to 55°C);

Ambient: 0 to 160°F (-17 to 72°C).

Pressure Limits:

Brass/SS: 200 psi (13.8 bar);

PVC: 150 psi (10 bar).

Process Connection: See Series EFF.

Output: Current sinking, square wave pulse, opto-isolated, 550 Hz @ 20 ft/s.

Power Requirements: 12 to 25 VDC @ 250 mA; (12 to 25 VDC @ 40 mA (max.

250 mA) - LOP option).

Electrical Connection: Terminal block.

Conductivity: 20 microSiemens/cm.

Enclosure Material: Housing: Die-cast powder-coated aluminum.

Enclosure Rating: NEMA 4X (IP66).

Weight: 3 lb (1361 g).

SeriesEFS2

Example

Series

Size/Material

Options

1P

1P

1B

1S

2P

2B

2S

3P

3B

3S

EFS2

EFS2

Note: Need to purchase with Series EFF fittings for proper installation.

Hastelloy® is a registered trademark of Hanes International

RFO

RFO

IMM

FOR

LOP

Ne

w P

rod

uc

tsNPB-42

Price

$671.00b

-

+95.00b

+207.00b

+23.25b

+127.00b

+289.00b

+91.50b

+204.00b

+380.00b

+172.00b

+104.00b

+18.50b

b Items are subject to Schedule B discounts.

EFS2-1P-RFO

Insertion Electromagnetic Flow Sensor

1 to 3˝ Pipe, PVC

1 to 3˝ Pipe, Brass

1 to 3˝ Pipe, 316 SS

4 to 10˝ Pipe, PVC

4 to 10˝ Pipe, Brass

4 to 10˝ Pipe, 316 SS

12˝ Pipe, PVC

12˝ Pipe, Brass

12˝ Pipe, 316 SS

Reverse Flow Output

Immersible (Urethane Potted Electrical Connection)

Fluoroelastomer O-ring

Low Power (12 to 25 VDC @ 40 mA) (max 250 mA)

Page 13: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

11

Magnetic Inductive Flow SensorNo Moving Parts, Frequency and 4 to 20 mA Output, Maintenance-Free

Series MFS Magnetic Inductive Flow Sensor is a compact, low cost alternative topaddle wheel sensors. Unlike sensors with moving parts, the MFS can be applied inapplications dealing with contaminated media. This series provides a reliable measuringtechnique, an obstruction free pipe cross-section, as well as a quick response time, makingthis series ideal for interference free operation. Any change in temperature, density,viscosity, concentration or electrical conductivity of the liquid, does not affect the outputsignal of this Magnetic Inductive Flow Sensor. This, in addition to its long-life cycle, makesthis series perfect for accurate reversible gauging of volume flow of conductive liquids inclosed piping.

Principles of Operation

The measuring pipe is in a magnetic field. If an electrically conductive medium with

a certain flow passes through the pipe, it passes at a right-angle to the magnetic

field, creating a voltage which is proportional to the average flow velocity and picked

up by two electrodes within the MFS. A frequency output signal is obtained that is

proportional to the flow (analog output option available).

FEATURES

• No moving parts

• No mechanical wear

• Maintenance-free

Series MFS

SPECIFICATIONS

Service: Water and other conductive

liquids.

Wetted Materials:

Electrodes: 316 TI SS;

Process Connections: 316 TI SS;

Measuring Pipe: PEEK-GF30;

Gasket: EPDM.

Accuracy: ±2% of reading.

Repeatability: 1%.

Temperature Limits:

Process: 32 to 194°F (0 to 90°C);

Ambient: 41 to 158°F (5 to 70°C).

Pressure Limits: 232 psi (16 bar).

Response Time: < 500 ms.

Power Requirements: 24 VDC ±10%.

Output:

Frequency: Square-wave, NPN;

Analog: 4 to 20 mA.

Loop Resistance: 250 Ω.

Current Consumption: Max 80 mA.

Minimum Conductivity of Mediu m:

50 µS/cm.

Flow Indication: LED green, flow

proportional blinking.

Enclosure Rating: NEMA 4 (IP65).

Process Connection: See model

chart.

Electrical Connection: Plug connector

M12x1.

Weight:

MFS-1X: 1.5 lb (0.68 kg);

MFS-2X: 1.7 lb (0.77 kg);

MFS-3X: 1.9 lb (0.87 kg).

Agency Approval: CE.

Model

MFS-11

MFS-21

MFS-31

MFS-12

MFS-22

MFS-32

Range GPM (LPM)

0.25 to 5.3 (1 to 20)

0.5 to 10.5 (2 to 40)

2.5 to 52.8 (10 to 200)

0.25 to 5.3 (1 to 20)

0.5 to 10.5 (2 to 40)

2.5 to 52.8 (10 to 200)

Minimum Output Signal

GPM (LPM)

0.13 (0.5)

0.25 (1)

1.3 (5)

0.13 (0.5)

0.25 (1)

1.3 (5)

Process

Connection

1/2˝ NPT

1/2˝ NPT

1˝ NPT

1/2˝ NPT

1/2˝ NPT

1˝ NPT

1-5/32[29.64]

1-1/8[28.96]

31/32[24.89]

3-7/32[81.53]

5-19/32[141.99]

3-1/32[77.22]

15/32[11.99]

LED

1” NPT 1-7/32[31.04]

9/16[13.95]

LED15/32[11.99]

1/2” NPT

19/32[15.27]

1-1/32[25.91]

2-1/4[56.90]

1-7/32[30.99]

3/8[9.91]

3-1/32[77.22]

3-7/32[81.53]5-1/16

[128.81]

1-3/8[34.80] Ø-11/16

[17.60]2-1/4

[56.90]

Ne

w P

rod

uc

ts

MFS-31 & MFS-32

MFS-11 & MFS-12MFS-21 & MFS-22

CALL TO ORDER | 800/872-9141

NPB-42

ACCESSORIES

MFS-C3, 4 Pin Cable Socket M12x1 Connect, 9.8 ft (3 m) . . . . . . . . . . . .$54.00b

MFS-C5, 4 Pin Cable Socket M12x1 Connect, 16.4 ft (5 m) . . . . . . . . . . . .63.00b

MFS-C10, 4 Pin Cable Socket M12x1 Connect, 32.8 ft (10 m) . . . . . . . . . .99.50b

Output

Frequency

Frequency

Frequency

Frequency & Analog

Frequency & Analog

Frequency & Analog

Price

$792.00b

792.00b

1036.00b

1112.00b

1112.00b

1356.00b

b Items are subject to Schedule B discounts.

Page 14: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

DWYER INSTRUMENTS, INC. | www.dwyer-inst.com12

The Series LOFM Low-Flow Magmeter is a liquid electromagnetic flow sensor thatuses the conductivity of fluids to measure flow. Liquid flow through its magnetic fieldproduces a voltage which is measured and translated into a pulse output signal. The LOFMcan be combined with the Series RTI for flow rate and total display. This meter comes witha variety of factory-installed adapters and O-rings. The LOFM comes in either 3/4’’ or 3/8’’pipe.

The Series LOFM can accurately measure flow rates as low as 0.03 gallons per minute.The meter is housed in a splash proof HDPE plastic, making it good for chemical injectionapplications. With no metal parts, the LOFM is corrosion-resistant and compatible with awide range of chemicals. With no moving parts, the meter can handle dirty waterapplications where moving parts might cause jamming or clogging. The LOFM comesstandard with Flaretek® fittings, but NPT adapters are available.

Features

• Low Cut Off Flow Rate

• No Metal Parts

• No Moving Parts

• No Straight Pipe Requirements

Low-Flow Electromagnetic Flow SensorHDPE Plastic Body, Pulse, Frequency and Analog Output

4-13/64[106.68]

2-3/32[53.34]

2-51/64[71.12]

3-1/2[88.90]

FLARETEK FITTINGSARE STANDARD

8-PIN CIRCULARBULKHEAD CONNECTOR ®

SPECIFICATIONS

Service: Compatible clean or dirty

non-coating, conductive liquids.

Range: LOFM-1: 0.2 to 20 GPM (0.01

to 1.3 l/s); LOFM-2: 0.03 to 3 GPM

(0.002 to 0.2 l/s).

Wetted Materials:

Body: PVDF; Electrodes: PVDF

carbon-fiber filled; Ground: PVDF

carbon-fiber filled; Fittings: PVDF;

Adapters: PVC or PVDF; O-rings:

EPDM or Fluoroelastomer (for NPT

fitting only).

Accuracy:

LOFM-1: +1% of reading, +0.005

GPM; LOFM-2: +1% of reading,

+0.002 GPM.

Temperature Limits: Process: 32 to

200°F (0 to 93°C); Ambient: 0 to 130°F

(-18 to 54°C).

Pressure Limit: 150 psi (10.3 bar).

Process Connections: Flaretek®

fittings standard in 3/4˝ or 3/8˝

flowbody (NPT threaded adapters also

available).

Output: Current sinking, square wave

pulse, opto-isolated, 30 VDC @ 5 mA

max. and 4 to 20 mA;

LOFM-1: 1892 pulses/gal

(500 pulses/L);

LOFM-2: 3785 pulses/gal

(1000 pulses/L).

Power Requirements: 10 to 15 VDC,

150 mA (linear power supply

recommended).

Conductivity: > 20 microSiemens.

Enclosure Material: HDPE with glass

fiber.

Enclosure Rating: NEMA 4X (IP66).

Weight: 2.20 lb (1.00 kg).

SeriesLOFM

Example

Construction

Size

NPT Adapters

(Optional Replace

FlareTek® Fittings)

O-Ring

(Only required

with NPT adapters)

FlareTek® Tubing Nut

(Only required with

FlareTek® fittings)

Flare Tool (Only

required with

FlareTek® fittings)

44C

44C

44F

42C

42F

88C

88F

84C

84F

000

1

1

2

LOFM

LOFM

1E

1E

1F

2E

2F

00

1TN

1TN

2TN

000

1FT

1FT

2FT

000

Flaretek® is a registered trademark of Entegris, Inc.

*The prices for the NPT adapters and O-rings are for the two required.

Ne

w P

rod

uc

tsNPB-42

LOFM-1-44C-1E-1TN-1FT

Low-Flow Magmeter (Comes standard with

FlareTek® fittings, NPT adapters available)

3/4˝

3/8˝

3/4˝ PVC NPT Adapter (LOFM-1 only)*

3/4˝ PVDF NPT Adapter (LOFM-1 only)*

1/2˝ PVC NPT Adapter (LOFM-1 only)*

1/2˝ PVDF NPT Adapter (LOFM-1 only)*

3/8˝ PVC NPT Adapter (LOFM-2 only)*

3/8˝ PVDF NPT Adapter (LOFM-2 only)*

1/4˝ PVC NPT Adapter (LOFM-2 only)*

1/4'' PVDF NPT Adapter (LOFM-2 only)*

No MNPT Adapter

3/4˝ EPDM (LOFM-1 only)*

3/4˝ Fluoroelastomer (LOFM-1 only)*

3/8˝ EPDM (LOFM-2 only)*

3/8˝ Fluoroelastomer (LOFM-2 only)*

No O-ring

3/4˝ FlareTek® Tubing Nut (LOFM-1 only)

3/8˝ FlareTek® Tubing Nut (LOFM-2 only)

No FlareTex® Tubing Nut

FlareTek®, Flare Tool, 3/8˝ Fitting (LOFM-1 only)

FlareTek®, Flare Tool, 3/8˝ Fitting (LOFM-2 only)

No FlareTek®, Flare Tool

Price

$868.00b

-

-

+16.25b

+104.00b

+16.25b

+104.00b

+16.25b

+104.00b

+16.25b

+104.00b

-

+30.00b

+37.00b

+30.00b

+37.00b

-

+37.00b

+37.00b

-

+172.00b

+172.00b

-

b Items are subject to Schedule B discounts.

Page 15: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

13

The Series IPFS Insertion Paddlewheel Flow Sensor is available for pipe sizesranging from 3 to 40˝ and available in brass, PVC or stainless steel. The Series IPFS hasan available hot tap model with a bronze or stainless steel valve assembly. The bearings aremade from ruby jewel to reduce the coefficient of friction and maintain high accuracy. TheSeries IPFS can be purchased with a variety of saddle fittings, Series SDF, that comes iniron or brass. The Series IPFS is good for large pipe and clean water applications. It isideal for chemical proportioning applications or any applications with rapidly changingfluid conductivity.

PRINCIPLE OF OPERATION

The IPFS uses the rotation of an impeller to measure flow. Liquid flow pushes the

rotor and the rotation is detected by a Hall-effect sensor. The output is a current

sinking pulse signal which can be connected to the Series RTI to display flow rate

and total or the Series BAT for a 4 to 20 mA signal conversion.

APPLICATIONS

• Clean Liquids

• Large Pipes

• Aquariums, Water Parks

• Water & Wastewater Monitoring

ACCESSORIES

• Series BAT, Blind Analog Transmitter, converts pulse output to 4 to 20 mA analog

output. Unit is loop powered, fits on the enclosure of the meter, and is fields

spannable.

• Series RTI, Rate Total Indicator, converts pulse output to 4 to 20 mA analog output

with local flow rate and totalization display. Unit is loop powered, can fit on the

enclosure of the meter, and provides a high/low flow alarm.

• Series PWD, Pulse Divider, for use with pacing electronic metering pumps. Unit

divides the input frequency to any number from 1 to 9999 with the use of rotary

switches to suit a number of metering pump inputs.

Paddlewheel Flow SensorHot-Tap Option, Field Adjustable Insertion, Wide Flow Range

2-3/4[69.70]

2-7/8[73.06]

4[101.42]

4[101.52]

PHONE219-878-8000

FAX210-872-9057

WEBWWW.DWYER-INST.COM

MADE IN XXXXXX

SPECIFICATIONS

Service: Compatible clean liquids.

Range: 0.3 to 30 ft/s (0.01 to 10 m/s).

Wetted Materials:

Shaft Body/Fitting: Brass, PVC, or 316 SS;

Rotor: PVDF;

Shaft: Nickel-bound tungsten carbide;

Bearings: Ruby jewel.

Valve Assembly: IPFS-1XX: Bronze (SS optional) with bronze ball valve;

O-ring: EPDM.

Accuracy: +1.5% FS.

Temperature Limits: Brass/SS: 200°F (93°C); PVC: 130°F (55°C).

Pressure Limits: Brass/SS: 200 psi (13.8 bar); PVC: 150 psi (10 bar).

Process Connection: IPFS-0XX: 1-1/2˝ male NPT; IPFS-1XX: 2˝ male NPT.

Output: Current sinking, square wave pulse.

Power Requirements: 5 to 24 VDC @1.5 mA (3.5 to 16 VDC -LOP option).

Electrical Connection: #22 AWG, 3 conductor, 18´ (5.5 m) cable length standard

(max. 2000´).

Enclosure Material: Housing: Die-cast powder-coated aluminum.

Enclosure Rating: NEMA 4X (IP66).

Weight: IPFS-1XX: 4 lb (1814 g); IPFS-2XX: 6 lb (2721 g); IPFS-3XX: 13 lb

(5897 g); IPFS-4XX: 15 lb (6804 g).

SeriesIPFS

Example

Series

Size/Material

Options

IPFS

IPFS

0SB

0SB

0SP

0SS

0LB

0LP

0LS

1SB

1SP

1SS

1LB

1LP

1LS

BAF

CRS

BAF

SAF

SVA

NVA

BPT

SPT

EXT

Hot-Tap Option(Shown installed on pipe)

Hot-Tap Option

*SS is stem and fitting. For SS valve order SVA option.

Ne

w P

rod

uc

ts

CALL TO ORDER | 800/872-9141

NPB-42

Price

$465.00b

+110.00b

-

+257.00b

+210.00b

+69.50b

+295.00b

+464.00b

+399.00b

+614.00b

+523.00b

+485.00b

+649.00b

+80.00b

+57.00b

+76.50b

+689.00b

-90.00b

+38.25b

+54.50b

+349.00b

IPFS-0SS-BAF

Insertion Paddlewheel Flow Sensor

Ceramic Shaft

2˝ Brass Adapter Fitting (IPFS-0XX only)

2˝ SS Adapter Fitting (IPFS-0XX only)

316 SS Valve Assembly (IPFS-1XX only)

No Valve Assembly (deduct price) (IPFS-1XX only)

1-1/2˝ Brass BPT Adapter (2 piece) (IPFS-0XX only)

1-1/2˝ SS Adapter (2 piece) (IPFS-0XX only)

12˝ Extension (IPFS-XL only)

Hot-Tap

No Hot-Tap

No Hot-Tap

No Hot-Tap

No Hot-Tap

No Hot-Tap

No Hot-Tap

Hot-Tap

Hot-Tap

Hot-Tap

Hot-Tap

Hot-Tap

Hot-Tap

Size

3 to 12˝

3 to 12˝

3 to 12˝

12 to 40˝

12 to 40˝

12 to 40˝

3 to 12˝

3 to 12˝

3 to 12˝

12 to 40˝

12 to 40˝

12 to 40˝

Material

Brass

PVC

SS

Brass

PVC

SS

Brass

PVC

SS*

Brass

PVC

SS*

b Items are subject to Schedule B discounts.

Page 16: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

DWYER INSTRUMENTS, INC. | www.dwyer-inst.com14

Flaretek® is a registered trademark of Entegris, Inc.

The Series PDWS Insertion Paddlewheel Flow Sensor is designed for pipe sizeranges from 1/2 to 8˝ with available materials of brass, stainless steel, PVC, andpolypropylene. The bearings are made of high-quality ruby jewel to reduce the coefficientof friction and maintain high accuracy. The Series PDWS has a wide variety of custom tee,saddle, or welded fittings that come in bronze, PVC, and stainless steel. The Series PDWSis ideal for chemical proportioning applications or any applications with rapidly changingfluid conductivity.

PRINCIPLE OF OPERATION

Uses the rotation of an impeller to measure flow. Liquid flow pushes the rotor and

the rotation is detected by a Hall-effect sensor. The output is a current sinking pulse

signal that can be connected to the Series RTI to display flow rate and total, or to

the Series BAT for a 4 to 20 mA analog signal.

APPLICATIONS

• Industrial Water/Wastewater Treatment

• Cooling Water Monitoring

• Industrial Fluid Control

• Chemical Proportioning

ACCESSORIES

• Series BAT, Blind Analog Transmitter, converts pulse output to 4 to 20 mA analog

output. Unit is loop powered, fits on the enclosure of the meter, and is fields

spannable.

• Series RTI, Rate Total Indicator, converts pulse output to 4 to 20 mA analog output

with local flow rate and totalization display. Unit is loop powered, can fit on the

enclosure of the meter, and provides a high/low flow alarm.

• Series PWD, Pulse Divider, for use with pacing electronic metering pumps. Unit

divides the input frequency to any number from 1 to 9999 with the use of rotary

switches to suit a number of metering pump inputs.

Paddlewheel Flow SensorLow Friction Bearings, Long Life

SPECIFICATIONS

Service: Compatible clean liquids.

Range: 0.3 to 30 ft/s (0.09 to 9.14 m/s).

Wetted Materials:

Sensor: Brass, 316 SS, PVC, or Polypropylene;

Rotor: PVDF;

Shaft: Nickel-bonded tungsten carbide (ceramic optional);

Bearings: Ruby jewel;

O-Ring: EPDM (fluoroelastomer optional).

Accuracy: ±1.5% FS.

Temperature Limits: Brass, 316 SS: 200°F (93°C); PVC, Polypropylene: 130°F

(55°C).

Pressure Limits: Brass: 200 psi (14 bar); 316 SS: 250 psi (17 bar); PVC,

Polypropylene: 175 psi (12 bar) @ 75°F (24°C); High Pressure Option: 400 psi (28

bar) (SS only).

Process Connection: See Series PWF.

Output: Current sinking, square wave pulse, opto-isolated.

Power Requirements: 6 to 24 VDC, 2 mA (max. 20 mA).

Electrical Connection: #22 AWG, 3 conductor, 18´ (5.5 m) cable (max. 2000´

run).

Enclosure Rating: NEMA 4X (IP66).

Weight: 2 lb (907 g).

SeriesPDWS

Example

Series

Size/Material

Options

1B

1B

1S

1P

1Y

2B

2S

2P

2Y

PDWS

PDWS

Note: Need to purchase with Series PWF fitting for proper installation.

CRS

CRS

IMM

FOR

HPO

Ne

w P

rod

uc

ts

1-19/32[40.64]

O-RING

RETAINING SLOT(FOR U-CLIP)

3-7/16[87.45]

23/32[18.43]

NPB-42

Price

$350.00b

+80.00b

+228.00b

-

+12.75b

+110.00b

+249.00b

+19.75b

+34.75b

+79.50b

+104.00b

+18.50b

+87.00b

b Items are subject to Schedule B discounts.

PDWS-1B-CRS

Insertion Paddlewheel Flow Sensor

1-1/2 to 3˝, Brass

1-1/2 to 3˝, 316 SS

1-1/2 to 3˝, PVC

1-1/2 to 3˝, Polypropylene

4 to 8˝, Brass

4 to 8˝, 316 SS

4 to 8˝, PVC

4 to 8˝, Polypropylene

Ceramic Shaft

Immersible (Urethane Potted Electrical Connection)

Fluoroelastomer O-ring

High Pressure Options (Use with SS only)

Page 17: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

15

The Series TBS Insertion Turbine Flow Sensor comes in brass or stainless steel andhas an available “hot-tap” model. The TBS has Series SDF fittings available to fit pipe sizes3 to 40˝. Ruby bearings give the turbine a low coefficient of friction and long life. The lowfriction bearings also allow the Series TBS to handle a wide range for flow rates.Additional options for this meter include adapter fittings and valve assemblies. Series TBSis suitable for clean liquids and large pipe applications.

PRINCIPLE OF OPERATION

The Series TBS uses a turbine equipped with miniature magnets in the rotor blades

to measure flow. Liquid flow rotates the turbine and a sensor detects the passage

of the magnets resulting in a square wave output. The output signal can then be

combined with the Series RTI for flow rate and total, and the Series BAT for a 4 to

20 mA signal conversion.

APPLICATIONS

• Chilled Water Monitoring in Building Automation Systems

• Water & Wastewater Monitoring

• Aquariums, Water Parks

ACCESSORIES

• Series BAT, Blind Analog Transmitter, converts pulse output to 4 to 20 mA analog

output. Unit is loop powered, fits on the enclosure of the meter, and is field

spannable.

• Series RTI, Rate Total Indicator, converts pulse output to 4 to 20 mA analog output

with local flow rate and totalization display. Unit is loop powered, can fit on the

enclosure of the meter, and provides a high/low flow alarm.

• Series PWD, Pulse Divider, for use with pacing electronic metering pumps. Unit

divides the input frequency to any number from 1 to 9999 with the use of rotary

switches to suit a number of metering pump inputs.

Liquid Turbine Flow SensorHot-Tap Option, 3 to 40˝ Field Adjustable Insertion

2-3/4[69.70]

2-7/8[73.06]

1/2˝ CABLEGLAND

2X 1/4˝ CABLE GLANDS

4[101.52]

4[101.42]

PHONE219-879-8000

FAX219-872-9057

WEBWWW.DWYER-INST.COM

MADE IN XXXXXX

SPECIFICATIONS

Service: Compatible clean liquids.

Range: 0.5 to 30 ft/s (0.15 to 9.14 m/s).

Wetted Materials:

Shaft Body/Fitting: Brass or 316 SS;

Rotor: PVFD;

Shaft/Bearings: Nickel-bound tungsten carbide/ruby jewel.

Valve Assembly: TBS-1XX: Bronze (SS optional) with bronze ball valve;

O-ring: EPDM.

Accuracy: ±1.5% FS.

Temperature Limit: 200°F (93°C).

Pressure Limit: 200 psi (14 bar).

Output: Current sinking square wave pulse, 100 mA max.

Power Requirements: 6 to 40 VDC @ 2 mA.

Process Connection: TBS-0XX: 1-1/2˝ male NPT; TBS-1XX: 2˝ male NPT.

Electrical Connection: #22 AWG, 3 conductor, 18´ (5.5 m), (max. 2000´ (650 m)).

Enclosure Material:

Housing: Die-cast powder-coated aluminum.

Enclosure Rating: NEMA 4X (IP66).

Weight: TBS-0SX: 4 lb (1814 g); TBS-0LX: 6 lb (2722 g); TBS-1SX: 13 lb

(5897 g); TBS-1LX: 15 lb (6804 g).

SeriesTBS

Example

Series

Model

Options

0SS

0SB

0SS

0LB

0LS

1SB

1SS

1LB

1LS

TBS

TBS

IMM

BAF

SAF

SVA

NVA

BPT

SPT

IMM

EXTHot-Tap Option

(Shown installed on pipe)

Hot-Tap Option

*SS is stem and fitting. For SS valve order SVA option.

Ne

w P

rod

uc

ts

CALL TO ORDER | 800/872-9141

NPB-42

b Items are subject to Schedule B discounts.

TBS-0SS-IMM

Insertion Turbine Flow Sensor

2˝ Brass Adapter Fitting (TBS-0XX only)

2˝ SS Adapter Fitting (TBS-0XX only)

316SS Valve Assembly (TBS-1XX only)

No Valve Assembly (deduct price) (TBS-1XX only)

1-1/2˝ Brass BPT Adapter (2 piece) (TBS-0XX only)

1-1/2˝ SS Adapter (2 piece) (TBS-0XX only)

Immersible (Urethane Potted Electrical Connection)

12˝ Extension (TBS-XLX only)

Hot-Tap

No Hot-Tap

No Hot-Tap

No Hot-Tap

No Hot-Tap

Hot-Tap

Hot-Tap

Hot-Tap

Hot-Tap

Size

3 to 12˝

3 to 12˝

12 to 40˝

12 to 40˝

3 to 12˝

3 to 12˝

12 to 40˝

12 to 40˝

Material

Brass

SS

Brass

SS

Brass

SS*

Brass

SS*

Price

$895.00b

-

+235.00b

+127.00b

+298.00b

+412.00b

+617.00b

+515.00b

+725.00b

+57.00b

+76.50b

+689.00b

-90.00b

+38.25b

+54.50b

+175.00b

+349.00b

Page 18: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

DWYER INSTRUMENTS, INC. | www.dwyer-inst.com16

Saddle FittingsSecures TBS, IPFS, IEFS Flow Sensors to 3 to 24˝ Pipe

The Series SDF Saddle Fittings are available for pipe sizes ranging from 3 to 24˝ andsecurely attach Series TBS, IPFS and IEFS flow meters to process application. Offered inPVC, ductile iron, and bronze materials, the SDF can be used with almost any pipingarrangement and is provided with o-rings, simplifying installation.

Series SDF

SPECIFICATIONS

Service: Compatible liquids.

Wetted Materials: See model chart.

Temperature Limits: See flow meter dependent.

Pressure Limits: See flow meter dependent.

Pipe Sizes: 3 to 24˝.

Weight: Consult factory.

BRASS IRON

PIPE DIAMETER(SEE “PIPE SIZE” IN MODEL CODE)

PIPE DIAMETER(SEE “PIPE SIZE” IN MODEL CODE)

Example

Series

Material

Pipe Size

Thread Size

SDF

SDF

I

I

B

03

03

04

06

08

10

12

14

16

18

20

22

24

15

15

20

SDF-B-XX

SDF-I-XX

Ne

w P

rod

uc

tsNPB-42

b Items are subject to Schedule B discounts.

Price

$177.00b

-

+140.00b

-

*+85.00b

+66.00b

+66.00b

+147.00b

+228.00b

+287.00b

+337.00b

+558.00b

+587.00b

+609.00b

+630.00b

-

-

SDF-I-03-15

Saddle Fittings for TBS, IPFS and IEFS Flow Sensors

Iron

Brass

6˝ (SDF-I only)

8˝ (SDF-I only)

10˝ (SDF-I only)

12˝ (SDF-I only)

14˝ (SDF-I only)

16˝ (SDF-I only)

18˝ (SDF-I only)

20˝ (SDF-I only)

22˝ (SDF-I only)

24˝ (SDF-I only)

For Series IEFS, IPFS, TBS non hot-tap models (1-1/2˝ male NPT)

For Series IEFS, IPFS, TBS hot-tap models (2˝ male NPT)

*$21.50b for iron.

Page 19: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

17

Fittings and TeesSaddles, Tees & Weld/Braze Fittings for Series EFS2

The Series EFF Fittings and Tees are used with the Series EFS2 InsertionElectromagnetic Flow Sensors. The Series EFF allows for sensor insertion in a wide rangeof pipe sizes. Multiple end connections are available to allow for easy installation in manyapplications. Series EFF is available in bronze, 304 stainless steel, 316 stainless steel, andPVC, further expanding application prospects.

Series EFF

SPECIFICATIONS

Service: Compatible liquids.

Wetted Materials: See model chart.

Temperature Limits: Flow meter dependent.

Pressure Limits: Flow meter dependent.

Connections: 1/2 to 12˝.

Weight: Consult factory.

1-5/8[41.15]

2-9/16[65.11]

EFF-S-PXXEFF-S-BXX

EFF-T-SFT-SS

EFF-S-DXX

Ne

w P

rod

uc

ts

b Items are subject to Schedule B discounts.

Size/Price

-0600

$261.00b

151.00b

N/A

+79.00b

-0600

$140.00b

118.00b

206.00b

-0800

$295.00b

179.00b

N/A

+84.00b

-0800

$140.00b

118.00b

206.00b

10˝

-1000

$367.00b

N/A

N/A

N/A

10˝

-1000

$140.00b

118.00b

206.00b

EFS2-3XX

12˝

-1200

$455.00b

N/A

N/A

N/A

EFS2-3XX

12˝

-1200

$140.00b

118.00b

206.00b

-0400

$206.00b

131.00b

316.00b

+74.00b

-0400

$140.00b

118.00b

206.00b

CALL TO ORDER | 800/872-9141

NPB-42

Example: EFF-T-CFT-0100-SS . . . . . . . . . . . . . . . . . . . . . . . . . . .$797.00b

To order an all 316 SS female thread 1˝ tee for Series EFS2-1XX

Electromagnetic Flow Sensor.

Model

EFF-T-BFT

EFF-T-BFS

EFF-T-PME

EFF-T-CFT

EFF-T-SFT

-SS

Model

EFF-S-DXX

EFF-S-PXX

EFF-S-BXX

-LPS

Model

EFF-W-BXX

EFF-W-CXX

EFF-W-SXX

Size/Price

EFS2-2XX

Size/Price

EFS2-2XX

For Use With

Tee Fitting Description

Bronze/Female Thread

Bronze/Female Sweat (For Copper Tubing)

PVC/Male Stub End

Carbon Steel/Female Thread

304 SS/Female Thread

All 316 SS Option

For Use With

Saddle Fitting Description

Ductile Iron

PVC (See Note 2)

Bronze

Installed on 16˝ Long Pipe Stub Option (PVC Only)

For Use With

Weld/Braze Fitting Description

Bronze

Carbon Steel

316 SS

EFS2-1XX

-0300

$272.00b

115.00b

274.00b

+69.00b

EFS2-1XX

-0300

$140.00b

118.00b

206.00b

EFS2-1XX

-0200

$279.00b

279.00b

135.00b

261.00b

377.00b

+663.00b

-0300

$344.00b

344.00b

N/A

N/A

N/A

N/A

-0400

$476.00b

476.00b

N/A

N/A

N/A

N/A

1-1/2˝

-0150

$259.00b

259.00b

128.00b

220.00b

367.00b

+638.00b

-0100

$224.00b

224.00b

124.00b

179.00b

357.00b

+618.00b

Page 20: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

DWYER INSTRUMENTS, INC. | www.dwyer-inst.com18

Fittings and TeesSaddles, Tees, and Weld/Braze Fittings for Series PDWS

The Series PWF Fittings and Tees are used with the Series PDWS InsertionPaddlewheel Flow Sensors. The Series PWF allow for sensor insertion in a wide range ofpipe sizes. Multiple end connections are available to allow for easy installation in manyapplications. Series PWF is available in bronze, 304 stainless steel, 316 stainless steel, andPVC, further expanding application prospects.

Series PWF

SPECIFICATIONS

Service: Compatible liquids.

Wetted Materials: See model chart.

Temperature Limits: See model chart.

Pressure Limits: See model chart.

Connections: 1/2 to 8˝.

Weight: Consult factory.

2-29/64[62.32]

1-5/8[41.15]

PWF-B-PXX

PWF-S-BXX

PWF-T-SFT-SS

PWF-S-DXX

Ne

w P

rod

uc

ts

b Items are subject to Schedule B discounts.

NPB-42

Model

PWF-T-BFS

PWF-T-BFT

PWF-T-PME

PWF-T-CFT

PWF-T-SFT

-SS

-HP

Model

PWF-S-DXX

PWF-S-PXX

PWF-S-BXX

-LPS

Model

PWF-W-BXX

PWF-W-CXX

PWF-W-SXX

-HP

Size/Price

Size/PricePDWS-2XX

Size/Price

PDWS-2XX

For Use With

Tee Fitting Description

Bronze/Female Sweat (For Copper Tubing)

Bronze/Female Thread

PVC/Male Stub End

Carbon Steel/Female Thread

304 SS/Female Thread

All 316 SS Option

High Pressure Option (SS or CS Only)

For Use With

Saddle Fitting Description

Ductile Iron

PVC

Bronze

Installed on 16˝ Long Pipe Stub Option (PVC Only)

For Use With

Weld/Braze Fitting Description

Bronze

Carbon Steel

316 Stainless Steel

High Pressure Option (SS or CS Only)

1/2˝

-0050

$224.00b

224.00b

104.00b

151.00b

316.00b

+552.00b

+115.00b

3/4˝

-0075

$234.00b

234.00b

114.00b

151.00b

316.00b

+562.00b

+115.00b

-0100

$244.00b

244.00b

124.00b

179.00b

357.00b

+618.00b

+115.00b

1-1/2˝

-0150

$259.00b

259.00b

128.00b

220.00b

367.00b

+638.00b

+115.00b

-0200

$279.00b

279.00b

135.00b

261.00b

377.00b

+663.00b

+115.00b

PDWS-1XX

-0300

$344.00b

344.00b

N/A

N/A

N/A

N/A

N/A

-0400

$476.00b

476.00b

N/A

N/A

N/A

N/A

N/A

Example: PWF-T-CFT-0050-SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$703.00b

To order an all 316 SS female thread 1/2˝ tee for Series PDWS-1XX Paddlewheel Flow Meter.

PDWS-1XX

-0300

$272.00b

115.00b

274.00b

+69.00b

PDWS-1XX

-0300

$140.00b

118.00b

206.00b

+115.00b

-0400

$206.00b

131.00b

315.00b

+74.00b

-0400

$140.00b

118.00b

206.00b

+115.00b

-0600

$261.00b

151.00b

N/A

+79.00b

-0600

$140.00b

118.00b

206.00b

+115.00b

-0800

$295.00b

179.00b

N/A

+84.00b

-0800

$140.00b

118.00b

206.00b

+115.00b

Page 21: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

19

The Series RTI Rate/Total Indicator is an indicator/transmitter that takes the pulseoutput signal from compatible flow meters, displays flow rate and total, and providesoutput signals. It is compatible with the Series EFS2, IEFS, PDWS, TBS and FLMG. TheSeries RTI can be mounted on either a wall or meter and has an additional panel mountoption. The RTI offers accessory mounting kits making it easy to change the mountingorientation. It also features high environmental protection with semi-flexible urethanepotted electrical components.

RTI is powered by an external DC voltage and has a pulse and 4 to 20 mA output signal.Additional options are temper-evidence, non-resettable total, dual relay output, and more.

The RTI is useful anywhere a compatible flow meter is used and flow rate and total aredesired.

APPLICATIONS

• Water Treatment

• Water Utility

• Industrial Chemical Handling

Rate/Total IndicatorLoop Powered, Converts Pulse Frequency to 4 to 20 mA, High/Low Flow Alarm

5[126.92]

3-15/16[99.82]

4-57/64[124.31]

2-5/32[54.92]

3[76.19]

3-5/8[92.08]

3-15/16[99.93]

SPECIFICATIONS

Input: 5 V pulse or contact closure; 1.0 to 1500 pulses/s.

Temperature Limits: -22 to 148°F (-30 to 65°C).

Output:

Current Sinking Square Wave Pulse: Scaled pulse output

(0.1 s duration 6.1 Hz max. or high alarm output or low alarm output),

sensor pass-through pulse output (un-scaled); Pulse Output Range:

0.1 to 9999999.9 units/pulse.

Analog: 4 to 20 mA, 24 to 30 VDC.

Power Requirements: 12 to 30 VDC @ 4 mA (4 to 20 mA when loop-powered).

Display: Rate: 6 digits, 1/2˝ H LCD; Total: 8 digits, 5/16˝ character height.

K-Factor Range: 0.001 to 99999.999.

Flow Alarm Output Range: 0.01 to 999999.99.

Enclosure Material Housing: Die-cast powder-coated aluminum; Faceplate

#HP92W Lexan.

Enclosure Rating: NEMA 4X (IP66).

Electrical Connection: Terminal blocks, #22 AWG, 3 conductor 18´ (5.5 m) cable

(2000´ max.).

Mounting: See model chart.

Weight: 3 lb (1361 g).

SeriesRTI

Example

Series

Mounting

Options

DPS

DPS

TEV

NRT

VPS

DRO

HDC

M

M

W

P

RTI

RTI

RTI-W RTI-MShown installed on Series EFS2

*Meter sold separately

The RTI is a Rate/Total Indicator that uses the pulse output from the following Dwyer flow meters

series* and displays flow rate and total.

*Compatible Series: EFS2, IEFS, PDWS, PFT, TBS and FLMG.

RTI-P

Ne

w P

rod

uc

ts

b Items are subject to Schedule B discounts.

CALL TO ORDER | 800/872-9141

NPB-42

MMK, Meter Mounting Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$127.00b

WMK, Wall Mounting Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70.50b

RTI-M-DPS

Rate/Total Indicator, Loop-powered

Meter-mounted*

Wall-mounted

Panel-mounted

Built-in 115 VAC/12-24 Dual Power Supply (RTI-M only)

Tamper-Evident*

Non-resettable Total

Built-in 115 VAC Power Supply (RTI-M only)

Dual Relay Output

Hinged Display Cover (not with DPS or VPS)

Price

$543.00b

-

-

-

+231.00b

+24.25b

+31.25b

+84.50b

+61.50b

+61.50b

Page 22: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

DWYER INSTRUMENTS, INC. | www.dwyer-inst.com20

The Series BAT Blind Analog Transmitter is a non-indicating, 4 to 20 mA transmitterfor use with the Series EFS2, IEFS, PDWS, TBS and FLMG. The BAT is easy to set upand can be either wall or meter mounted. It takes a pulse frequency output from thecompatible flow meters and converts it into a continuous 4 to 20 mA analog output signal.The frequency for the flowmeter output signal can be adjusted using four rotary switcheson the back of the transmitter and a microcontroller automatically scales all other valuesaccordingly. The microcontroller is also able to average inputs for more stable readingoutputs. The rate for averaging is adjustable and ranges from 2 to 16 seconds. Power forthe BAT is supplied by a current loop, making only 2 wires necessary. This unit featureshigh environmental protection with semi-flexible urethane potted electrical components.

Blind Analog TransmitterConverts Pulse Frequency to 4 to 20 mA, Loop Powered

3[76.19]

2-5/32[54.92]3-7/8

[98.57]

4-15/16[125.44]

5[126.92]

3-5/8[92.08]

3-15/16[100.02]

PHONE219-878-8000

FAX219-872-99057

WEBWWW.DWYER-INST.COM

MADE IN XXXXXX

SPECIFICATIONS

Input: Open-collector solid state sensor. Averaging: 2, 4, 8, 16 s (DIP switch

selectable); Pulse Frequency: Min. 10 Hz @ 20 mA; Max. 999.9 Hz (rotary DIP

switch selectable).

Temperature Limits: 32 to 130°F (0 to 55°C).

Output: 4 to 20 mA.

Power Requirements: 24 to 36 VDC @ 4 to 20 mA when loop powered.

Response Time: 2 to 60 s; 90% FS (depends on input averaging).

Loop Resistance: 0 to 1300 Ω max. (see service manual).

Enclosure Material: Die-cast powder-coated aluminum.

Enclosure Rating: NEMA 4X (IP66).

Electrical Connections: Terminal block.

Mounting: See model chart.

Weight: 3 lb (1361 g).

SeriesBAT

BAT-M shown installed

on Series EFS2 meter.

Meter sold separately.

BAT-W

*Compatible Series: EFS2, IEFS, PDWS, TBS and FLMG.

Model

BAT-M

BAT-W

APPLICATIONS

• Telemetry

• Data Logging

• Distributed Control Systems

• Programmable Controller

• Chart Recording

The Series FPCA Flow Power Control Accessories include mounting kits, powerconverters, and power supplies for compatible flow meters. These accessories simplifyinstallation by offering meter and wall mounting options. Furthermore, power input andsupply are no longer an issue with the power converter and dual power supply. The WMKcan be used to mount Series BAT, RTI, or PWD on Series PDWS. The MMK can be usedto mount either Series BAT or RTI to a wall with the use of Series EFS2, IEFS, PDWS,IPFS, TBS, or FLMG. Model PWC1 can be used with Series PDW, EFS2, or IEFS toconvert 115 VAC to 25 VDC. Model PWC2 can be used with Series EFS2, IEFS, PDWS,IPFS, and TBS to convert 115 VAC to 12/24 VDC and provide dual power output for usewith Series BAT and RTI.

3/4[18.93]

2-59/64[74.17]

2X 1-1/4[31.69]

SPECIFICATIONS

WMK/MMK

Temperature Limits: -22 to 148°F (-30 to 65°C).

Enclosure Material: Die-cast powder-coated aluminum.

Weight:

WMK: 1.25 lb (567 g);

MMK: 1.75 lb (794 g).

PWC1/PWC2

Temperature Limits: 32 to 140°F (0 to 60°C).

Output: 24 VDC @ 500 mA.

Power Requirements: 120 VAC, 60 Hz, 19 W.

Electrical Connection: 22-18 AWG screw terminal.

Weight: Contact factory.

Model

WMK

MMK

PWC1

PWC2

PWC1 PWC2

MMKWMK

Flow Power/Controls AccessoriesPower Supplies & Mounting Options for Series BAT, RTI, PWD, IPFS,TBS, FLMG, PDWS, EFS2, IEFS, IPFS

SeriesFPCA

4-15/16[125.22]

4-15/16[125.23]

2

PHONE219-878-8000

FAX219-872-9057

WEBWWW.DWYER-INST.COM

MADE IN: XXXXX

3-15/64[82.04]

2-13/64[55.88]

1-15/16[49.02]

Ne

w P

rod

uc

ts

PWC1 PWC2

b Items are subject to Schedule B discounts.

NPB-42

MMK, Meter Mounting Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$127.00b

WMK, Wall Mounting Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70.50b

Price

$427.00b

427.00b

Description

Blind Analog Transmitter, Meter-Mounted*

Blind Analog Transmitter, Wall-Mounted

Description

Wall to Meter Mounting Kit

Meter to Wall Mounting Kit

Power Converter, Plug-in, 115 VAC, 24 VDC

Dual Power Supply, Plug-in, 115 VAC, 12/24 VDC

Price

$70.50b

127.00b

88.00b

200.00b

b Items are subject to Schedule B discounts.

Page 23: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

21

Solar Panel KitReliable 5 Watt Solar Panel for Remote Applications or Back-Up Power

The Model SPK Solar Panel makes it possible to use Dwyer flowmeters in remoteapplications where a reliable source of electricity is not available or practical. The SPK isintended for use with a standard 12 V, 22 to 33 amp-hour sealed lead acid battery (notincluded). It comes standard with a charge controller and corrosion-resistant mountinghardware. The SPK can also be used to provide up to a 40-day back-up power supply forperiods of darkness.

APPLICATIONS

• Remote metering applications where electricity is unavailable.

• Back-up power supply for uninterrupted operation.

ModelSPK

SPECIFICATIONS

Temperature Limits: -40 to 158°F (-40 to 70°C).

Output: 17 V @ 290 mA.

Change Controller: High efficiency PWM regulator with temperature

compensation and built-in lightning protection.

Mounting: Bracket, band clamps and mounting hardware for 1-1/2 to 2˝ vertical

pipe included.

Weight: 4 lb (1814 g).

13-7/8

8-7/8

1

The Series PWD Pulse Divider is designed for pacing electronic metering pumps. Theenclosed rotary switch setting mechanism can be manually set to any number from 0 to9999 pulses. Once the divider has received the set number of pulses from the meter, itoutputs one pulse to stroke the pump. The PWD is also useful in boiler and cooling towerfeed and bleed operations, and for lowering frequency output of high frequency meters.The PWD is available in two different housings, one is an enclosure that can be mountednear the pump, and the other is a watertight housing for mounting on the meter.

APPLICATIONS

• Electronic metering pumps

• Boiling/cooling tower feed and bleed

• Lower frequency output or high frequency meters

SPECIFICATIONS

Input: Pulse wave 350 Hz (pulses/s) max.

Temperature Limits: 0 to 130°F (-18 to 55°C).

Output: Solid state relay 0 to 250 VAC/DC @ 170 mA max., 0.1 s pulse width, 8 Hz

max. (rotary DIP switch selectable).

Power Requirements: 7 to 30 VDC @ 4 mA, 20 mA max.

Enclosure Rating: NEMA 4X (IP66).

Electrical Connection:

Input:

PWD-W: Dwyer connector;

PWD-M: Terminal;

Output:

PWD-W: Pump connector (on 24˝ (0.61 m) lead);

PWD-M: 18´ (5.5 m) lead.

Mounting: See model chart.

Weight: 4.4 lb (2000 g).

TO ADJUST DIVIDER, DISCONNECT FROM POWERTHEN REMOVE COVER AND SET SWITCHES

PWD-X

PWD-X

1[25.40]5-3/32

[129.54]

2-11/16[68.39]

Model

PWD-M

PWD-W

PWD-W

Pulse DividerDivides Pulses from 0 to 9999, Easily Adjustable Rotary Switches

Series PWD

Ne

w P

rod

uc

ts

b Items are subject to Schedule B discounts.

CALL TO ORDER | 800/872-9141

NPB-42

Model SPK, Solar Panel Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$502.00b

Price

$154.00b

189.00b

Description

Pulse Divider, Meter Mounted

Pulse Divider, Wall Mounted

b Items are subject to Schedule B discounts.

Page 24: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

DWYER INSTRUMENTS, INC. | www.dwyer-inst.com22

Multi-Jet Water MeterEconomical, Brass Body, Dry Dial

The Series WM2 Multi-Jet Water Meter is ideal for commercial and industrialapplications. The multi-jet design allows for simplicity and accuracy with wide flow ranges,even in low flow applications. The magnetically driven, hermetically sealed register willnot leak or fog and is completely separated from the water. These water meters aredesigned for long service life and maintenance-free operation, even under harsh conditions.

FEATURES

• Magnetic drive – water is sealed from entering register

• Dry dial won’t discolor or fade – hermetically sealed from the elements

• Integral strainer that protects meters from particulate damage

• Pointer-roller indicator

• Frost resistant body

• Includes two mounting adapters (couplings)

Series WM2

SPECIFICATIONS

Service: Water.

Wetted Materials:

Body: Brass, polyethylene;

Couplings: Brass;

Measuring Chamber: Polyethylene, ABS plastic, ferrite, acetal.

Flow Range: See model chart.

Accuracy: Transitional Flow: ±5%; Nominal Flow: ±2%.

Temperature Limit: 104°F (40°C).

Pressure Limit: 232 psi (16 bar).

Pressure Drop: See service manual.

Totalizing Display Maximum: See model chart.

Mounting Orientation: Horizontal.

Weight: See dimension chart.

H

L

WM

2-X-

C-XX

XX-X

X

W

Size

5/8 x 1/2´

5/8 x 3/4´

3/4´

1-1/2´

Coupling

Size

1/2´ NPT

3/4´ NPT

3/4´ NPT

1´ NPT

1-1/2´ NPT

2´ NPT

Nominal Flow Range

1 to 10

1 to 20

2 to 30

3 to 50

5 to 100

80 to 160

Max Flow

20

20

30

50

100

160

Model

WM2-A-C-01

WM2-A-C-02

WM2-A-C-03

WM2-A-C-04

WM2-A-C-06

WM2-A-C-07

Size

15 mm

20 mm

25 mm

32 mm

40 mm

50 mm

Coupling

Size

1/2˝ BSPT

3/4˝ BSPT

1˝ BSPT

1-1/4˝ BSPT

1-1/2˝ BSPT

2˝ BSPT

Nominal Flow Range

0.12 to 1.5

0.2 to 2.5

0.25 to 3.5

0.48 to 6

0.8 to 10

1.2 to 15

Max Flow

3

5

7

12

20

30

Model

WM2-B-C-08

WM2-B-C-10

WM2-B-C-11

WM2-B-C-12

WM2-B-C-13

WM2-B-C-14

Size

in (mm)

5/8 x 1/2 (15)

5/8 x 3/4

3/4 (20)

1 (25)

1-1/4 (32)

1-1/2 (40)

2 (50)

Spud NPSM

(BSPP)

3/4˝ (3/4˝)

1˝ (1˝)

1˝ (1˝)

1-1/4˝ (1-1/4˝)

1-1/2˝ (1-1/2˝)

2˝ (2˝)

2-1/2˝ (2-1/2˝)

Length ‘L’

in (mm)

6-1/2 (165)

7-1/2 (190)

7-1/2 (190)

10-1/4 (260)

10-1/4 (260)

11-13/16 (300)

11-13/16 (300)

Width ‘W’

in (mm)

3-45/64 (94)

3-45/64 (94)

3-45/64 (94)

3-55/64 (98)

3-55/64 (98)

4-51/64 (122)

5-45/64 (145)

Height ‘H’

in (mm)

4-15/64 (107.5)

4-15/64 (107.5)

4-15/64 (107.5)

4-5/8 (117.5)

4-5/8 (117.5)

5-9/16 (141.5)

6-31/32 (177)

Weight

lb (kg)

3.75 (1.7)

3.97 (1.8)

4.9 (2.2)

6.4 (2.9)

8.2 (3.7)

13.52 (6.17)

18.74 (8.5)

Transitional Flow

0.25

0.25

0.25

0.75

1.5

2

Transitional Flow

0.03

0.03

0.07

0.12

0.2

0.12

GPM (Gallons Per Minute)

m3/h

Ne

w P

rod

uc

tsNPB-42

Price

$55.00

61.00

84.50

109.00

213.00

331.00

Price

$55.00

61.00

109.00

121.00

213.00

331.00

Display Max

(Gallons)

9,999,999.99

9,999,999.99

99,999,999.9

99,999,999.9

99,999,999.9

99,999,999.9

Display Max

(m3)

99,999.9999

99,999.9999

99,999.9999

99,999.9999

999,999.9999

999,999.9999

Page 25: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

23

Multi-Jet Water Meter with Pulsed OutputEconomical, Brass Body, Dry Dial

The Series WMT2 Multi-Jet Water Meter is ideal for commercial and industrialapplications. The multi-jet design allows simplicity and accuracy with wide flow rangeseven in low flow applications. The meter is designed for long service life and relativelymaintenance-free operation, even under adverse conditions. The magnetically driven,hermetically sealed register will not leak or fog and is completely separated from the water.The reed switch is activated by a magnet on the dial, which is directly proportional to theflow rate. The output is perfect for remote monitoring of flow rate or flow totalization, andcan interface with PLC's, counters, data loggers, and SCADA systems.

FEATURES

• Magnetic Drive – water is sealed from entering register

• Dry dial won’t discolor or fade – hermetically sealed from the elements

• Integral strainer that protects meters from particulate damage

• Pointer-roller indicator

• Frost resistant body

• Pulsed output

• Includes two mounting adapters (couplings)

Series WMT2

SPECIFICATION

Service: Water.

Wetted Materials:

Body: Brass, polyethylene;

Couplings: Brass;

Measuring Chamber: Polyethylene, ABS plastic, ferrite, acetal.

Flow Range: See model chart.

Accuracy: Transitional Flow: ±5%; Nominal Flow: ±2%.

Temperature Limit: 104°F (40°C).

Pressure Limit: 232 psi (16 bar).

Pressure Drop: See service manual.

Totalizing Display Maximum: See model chart.

Output Signal: Pulse output with frequency proportional to flow rate.

Pulse Options: 0.1 gal, 1 gal, 10 gal, 100 gal per pulse (1 L, 10 L, 100 L per

pulse).

Electrical Rating: 0.01 A @ 24 VAC/DC.

Electrical Connections: Color-coded lead wires, 4.5´ (1.5 m) long.

Mounting Orientation: Horizontal.

Weight: See dimension chart.

WM

T2-X

-C-X

X-X

XX-X

X

H

L

W

Size

in (mm)

5/8 1/2 (15)

5/8 x 3/4

3/4 (20)

1 (25)

1-1/4 (32)

1-1/2 (40)

2 (50)

Spud NPSM

(BSPP)

3/4˝ (3/4˝)

1˝ (1˝)

1˝ (1˝)

1-1/4˝ (1-1/4˝)

1-1/2˝ (1-1/2˝)

2˝ (2˝)

2-1/2˝ (2-1/2˝)

Length ‘L’

in (mm)

6-1/2 (165)

7-1/2 (190)

7-1/2 (190)

10-1/4 (260)

10-1/4 (260)

11-13/16 (300)

11-13/16 (300)

Width ‘W’

in (mm)

3-45/64 (94)

3-45/64 (94)

3-45/64 (94)

3-55/64 (98)

3-55/64 (98)

4-51/64 (122)

5-45/64 (145)

Height ‘H’

in (mm)

4-15/64 (107.5)

4-15/64 (107.5)

4-15/64 (107.5)

4-5/8 (117.5)

4-5/8 (117.5)

5-9/16 (141.5)

6-31/32 (177)

Weight

lb (kg)

3.75 (1.7)

3.97 (1.8)

4.9 (2.2)

6.4 (2.9)

8.2 (3.7)

13.52 (6.17)

18.74 (8.5)

Size

5/8 x 1/2´

5/8 x 3/4´

3/4´

5/8 x 1/2´

5/8 x 3/4´

3/4´

1-1/2´

Coupling

Size

1/2´ NPT

3/4´ NPT

3/4´ NPT

1´ NPT

1/2´ NPT

3/4´ NPT

3/4´ NPT

1´ NPT

1-1/2´ NPT

2´ NPT

1´ NPT

2´ NPT

Nominal Flow Range

1 to 10

1 to 20

2 to 30

3 to 50

1 to 10

1 to 20

2 to 30

3 to 50

5 to 100

80 to 160

3 to 50

80 to 160

Max Flow

20

20

30

50

20

20

30

50

100

160

50

160

Model

WMT2-A-C-01

WMT2-A-C-02

WMT2-A-C-03

WMT2-A-C-04

WMT2-A-C-01-1

WMT2-A-C-02-1

WMT2-A-C-03-1

WMT2-A-C-04-1

WMT2-A-C-06-10

WMT2-A-C-07-10

WMT2-A-C-04-100

WMT2-A-C-07-100

Size

15 mm

20 mm

25 mm

32 mm

15 mm

32 mm

50 mm

32 mm

50 mm

Coupling

Size

1/2´ BSPT

3/4´ BSPT

1´ BSPT

1-1/4´ BSPT

1/2´ BSPT

1-1/4´ BSPT

2´ BSPT

1-1/4´ BSPT

2´ BSPT

Nominal Flow Range

0.12 to 1.5

0.2 to 2.5

0.25 to 3.5

0.48 to 6

0.12 to 1.5

0.48 to 6

1.2 to 15

0.48 to 6

1.2 to 15

Max Flow

3

5

7

12

3

12

30

12

30

Model

WMT2-B-C-08-1

WMT2-B-C-10-1

WMT2-B-C-11-1

WMT2-B-C-12-1

WMT2-B-C-08-10

WMT2-B-C-12-10

WMT2-B-C-14-10

WMT2-B-C-12-100

WMT2-B-C-14-100

GPM (Gallons Per Minute)

m3/h

Transitional Flow

0.25

0.25

0.25

0.75

0.25

0.25

0.25

0.75

1.5

2

0.75

2

Transitional Flow

0.03

0.05

0.07

0.12

0.03

0.12

0.3

0.12

0.3

Display Max

(Gallons)

9,999,999.99

9,999,999.99

9,999,999.99

99,999,999.9

9,999,999.99

9,999,999.99

9,999,999.99

99,999,999.9

99,999,999.9

99,999,999.9

99,999,999.9

99,999,999.9

Display Max

(m3)

99,999.9999

99,999.9999

99,999.9999

99,999.9999

99,999.9999

99,999.9999

999,999.9999

99,999.9999

999,999.9999

Ne

w P

rod

uc

ts

CALL TO ORDER | 800/872-9141

NPB-42

Price

$65.00

71.00

79.50

114.00

68.50

74.00

79.50

114.00

211.00

279.00

114.00

279.00

Price

$68.50

79.50

114.00

131.00

68.50

131.00

279.00

131.00

279.00

Pulse Rate

(Gal./Pulse)

0.1

0.1

0.1

0.1

1

1

1

1

10

10

100

100

Pulse Rate

(L/Pulse)

1

1

1

1

10

10

10

100

100

Page 26: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

DWYER INSTRUMENTS, INC. | www.dwyer-inst.com24

Model TFLS2

The Model TFLS2 Compact Tuning Fork Level Switch is an ideal choice for levelcontrol for powders. The TFLS2 incorporates a piezoelectric crystal that vibrates the forkat its natural frequency. When the fork comes in contact with a material, the vibration isdampened and the switch changes state. As the material is removed from the fork, theswitch changes back to its normal state. Featured in the TFLS2 is user selectable fail-safeoperation of the contacts. The unit is not affected by vibration from conveying systems,motors, or the movement of material. Its compact size allows for mounting in places alarger tuning fork level switch may not fit, providing great versatility.

The Model TFLS2 is easy to use with adjustable calibration, and no mechanical movingparts means no routine maintenance. The TFLS2 is not affected by the dielectric constantof the sensed material, making it superior to a comparable capacitance level switch forapplications where the dielectric constant is low, more than one material is being used inthe single vessel, and when material moisture content can change. The level switch is alsogreat for applications when the bulk density is too low for a rotating paddle level switch,making it the ideal choice for low density bulk solids and liquids.

SPECIFICATIONS

Service: Dry powder compatible with

wetted materials. Can detect bulk

materials submerged in liquid.

Sensitivity: Min. bulk solid density: 4.4

lb/ft3 (70 g/l); Max. particle size: 0.4˝ (10

mm).

Wetted Materials: 316 L SS.

Temperature Limits:

Ambient: -40 to 140°F (-40 to 60°C);

Process: -40 to 266°F (-40 to 130°C).

Pressure Limit: 600 psi (40 bar).

Power Requirement: 20 to 250 VAC,

50/60 Hz.

Power Consumption: 10 VA.

Enclosure: Aluminum, painted.

Enclosure Rating: IP65.

Switch Type: SPDT.

Electrical Rating: 5 A @ 250 VAC.

Electric Connections: Screw terminals.

Conduit Connection: 1/2˝ female NPT

x 2.

Process Connections: 1˝ male NPT.

Indication Lights: Internal: Green and

red LED’s.

Sensing Delay: 0 to 6 s.

Weight: 2.4 lb (1.09 kg).

Compact Tuning Fork Level SwitchCompact, Cost Effective, For Bulk Solids

ModelCTF Mini Tuning Fork Level Switch

Compact, Cost Effective, DIN Connection

The Model CTF Mini Tuning Fork Level Switch is an ideal choice for level control forpowders. The CTF incorporates a piezoelectric crystal that vibrates the fork at its naturalfrequency. When the fork comes in contact with a material, the vibration is dampened andthe switch changes state. As the material is removed from the fork, the switch changesback to its normal state. The unit is not affected by vibration from conveying systems,motors, or the movement of material. Its compact size and DIN connection allow forapplication in places a larger tuning fork level switch may not be suitable, providing greatversatility.

The Model CTF is easy to use with no calibration required, and no mechanical movingparts mean no routine maintenance. The CTF is not affected by the dielectric constant ofthe sensed material, making it superior to a comparable capacitance level switch forapplications where the dielectric constant is low, more than one material is being used inthe single vessel, and when material moisture content can change. The level switch is alsogreat for applications when the bulk density is too low for a rotating paddle level switch,making it the ideal choice for low density bulk solids and liquids. Comes standard with auser friendly PNP/NPN configurable output.

APPLICATIONS

Lime, styrofoam, tobacco, dry cereals, sugar, animal feed, milk powder, flour,

insulation, cement, paper shavings, plastic granules, sawdust, carbon black, light

fibers, detergent powders, dyes, chalk, silica, sand, wood chips.

SPECIFICATIONS

Service: Dry powder compatible with

wetted materials. Can detect bulk

materials submerged in liquid.

Sensitivity: Min. bulk solid density: 4.4

lb/ft3 (70 g/l).

Wetted Materials: 304 SS and 316L

SS.

Temperature Limits:

Ambient: -40 to 140°F (-40 to 60°C);

Process: -40 to 212°F (-40 to 100°C).

Pressure Limit: 600 psi (40 bar).

Power Requirement: 12 to 55 VDC.

Power Consumption: 10 mA @ 12 to

24 VDC; 0.5 W (max.).

Enclosure: Aluminum, painted.

Enclosure Rating: IP65.

Switch Type: 3-wire PNP/NPN output.

Electrical Rating: 350 mA (max) @ 12

to 55 VDC.

Conduit Connection: Valve plug DIN

43650.

Process Connections: 1˝ male NPT.

Indication Lights: External red LED.

Sensing Delay: Max. covered probe: 1

to 3 s.; Uncovered probe: 1 to 3 s.

Weight: 2.2 lb (1.0 kg).

HEX1/5˝

1˝ NPT

3-15/16[100.00]

1-3/16[30.00] 4-9/64

[105.00]

Ø1-1/2[38.00]

Ne

w P

rod

uc

ts

1˝ NPT

3-5/16[84.00]

4-9/64[105.00]

63/64[25.06]

25/32[19.99]

NPB-42

b Items are subject to Schedule B discounts.

Model TFLS2-01, Compact Tuning Fork Level Switch . . . . . . . . . . . . . .$360.00b

b Items are subject to Schedule B discounts.

Model CTF-01, Mini Tuning Fork Level Switch . . . . . . . . . . . . . . . . . . . .$230.00b

Page 27: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

25

The Model VRLS Vibrating Rod Level Switch is an economical choice in leveldetection of powders and bulk solids. The VRLS utilizes a piezoelectric crystal thatvibrates the rod at a natural frequency. Once the rod comes in contact with the material,the vibration will be dampened and the switch will change state. Once the rod is uncoveredby the material, the switch will revert to its normal state. Perfect for silo or hopperapplications, its probe design allows for self-cleaning, ensuring no build-up or bridging ofmaterial and accurate detection. Sensitivity is adjustable for detection ranging from largegranular material to small powders with low bulk densities. The failsafe mode can be setfor failure on high level or failure on low level using a selector switch in the enclosure.

APPLICATIONS

Lime, styrofoam, tobacco, dry cereals, sugar, animal feed, milk powder, flour,

insulation, cement, paper shavings, plastic granules, sawdust, carbon black, light

fibers, detergent powders, dyes, chalk, silica, and wood chips.

SPECIFICATIONS

Service: Dry powder or bulk materials

compatible with wetted materials.

Sensitivity: Min. bulk density of 20

lb/ft3 (320 kg/m3).

Wetted Materials: 304 SS.

Temperature Limits:

Ambient: -40 to 140°F (-40 to 60°C);

Process: -40 to 176°F (-40 to 80°C).

Pressure Limit: 150 psi (10 bar).

Power Requirement: 20 to 250

VAC/VDC, 50/60 Hz.

Power Consumption: 15 VA.

Enclosure: Aluminum, painted.

Enclosure Rating: IP65.

Switch Type: SPDT.

Electrical Rating: 5 A @ 250 VAC.

Electrical Connections: Screw

terminals.

Conduit Connection: 1/2˝ female NPT

x 2.

Process Connection: 1˝ male NPT.

Indication Lights: Internal: green and

red LED.

Sensing Delay: 0 to 6 s.

Weight: 4.4 lb (2.0 kg).

Vibrating Rod Level SwitchEconomical, No Material Build Up, For Powder or Bulk Solids

4-9/32[108.83]

4-29/64[113.03]

1˝ NPT51/64[20.19]

10-27/32˝[275.35]

Ø3/4[18.87]

ModelVRLS

Flush Capacitance Level SwitchMaintenance Free, Flush Mounting

ModelFCLS

7-11/32[186.34]

4-3/8[110.95]

3-25/32[96.16]

1/2˝ NPT5-57/64[149.43]

4-9/32[108.83]

6-3/32[154.94]

The Model FCLS Flush Capacitance Level Switch is ideal for level measurement ofliquids and bulk solids to trigger an alarm or close a filler inlet. No probe design allows forinstallation where space is constrained or where material flow or material build up woulddamage a probe. With no moving parts, this level switch assures no jams, no wear, nothingto break, and no maintenance. Comes standard with IP65 housing with a maximumpressure limit of 285 psi (19.7 bar).

SPECIFICATIONS

Service: Liquids, powder, and bulk

materials compatible with wetted

materials.

Wetted Materials: 304 SS.

Insulated Materials: PTFE.

Temperature Limits:

Ambient: -4 to 140°F (-20 to 60°C);

Process: -4 to 176°F (-20 to 80°C).

Pressure Limit: 285 psi (19.7 bar).

Power Requirements: 110 or 220

VAC.

Power Consumption: 2 W.

Enclosure: Aluminum, painted.

Enclosure Rating: IP65.

Switch Type: SPDT.

Electrical Rating: 3 A @ 250 VAC.

Electrical Connections: Screw

terminals.

Conduit Connection: 2 x 1/2˝ female

NPT.

Process Connection: 2.5˝ - x 5

kg/cm2 JIS flange.

Mounting Orientation: Side mount.

Fail Safe: Selectable fail high or fail

low.

Adjustable Sensitivity: 1 to 20 pF.

Time Delay: 0 to 6 s.

Weight: 7.1 lb (3.2 kg).

Ne

w P

rod

uc

ts

CALL TO ORDER | 800/872-9141

NPB-42

b Items are subject to Schedule B discounts.

Model VRLS-01, Vibrating Rod Level Switch . . . . . . . . . . . . . . . . . . . . .$399.00b

b Items are subject to Schedule B discounts.

Model FCLS-01, Flush Capacitance Level Switch . . . . . . . . . . . . . . . . .$599.00b

Page 28: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

DWYER INSTRUMENTS, INC. | www.dwyer-inst.com26

The Series ULL is a direct-install level transmitter designed for non-contact measurementof liquid levels. The ULL utilizes ultrasonic technology paired with automatic temperaturecompensation to provide reliable and accurate measurements in virtually all conditions.Sophisticated algorithms are used to overcome acoustic interferences and false echoes. Anintegrated LCD screen and four push buttons allow for quick and easy programming on asimple menu structure. Diagnostic capabilities and a fail-safe output signal make the ULLan essential choice in critical applications.

FEATURES

• Direct installation

• Integral LCD display

• High accuracy (0.25% of max. range)

• Automatic ambient temperature compensation

SPECIFICATIONS

Service: Compatible liquids.

Wetted Materials:

Sensor: Polypropylene;

Acoustic window: ECTFE.

Ranges:

ULL-1XXX: 0.82 to 16.4 ft (0.25 to 5 m);

ULL-2XXX: 1.96 to 49.2 ft (0.6 to 15 m).

Accuracy: 0.25% of max. range (at 20°C).

Resolution: 0.04˝ (1 mm).

Blind Zone:

ULL-1XXX: 0.8´ (0.25 m);

ULL-2XXX: 1.96´ (0.6 m).

Beam Angle: 5° @ 3 db point.

Temperature Limits: -40 to 158°F (-40 to 70°C).

Temperature Compensation: Automatic.

Pressure Limits: 13.5 to 30 psi (0.9 to 2 bar).

Power Requirement: 18 to 28 VDC.

Output Signal: 4 to 20 mA.

Loop Resistance: Max. 727 Ω @ 28 VDC.

Electrical Connections: Screw terminal.

Conduit Connection: 1/2˝ NPT, cable gland (optional).

Process Connection: 2˝ NPT, 2˝ BSP (optional).

Enclosure Material: ABS & UV resistant.

Enclosure Rating: NEMA 4 (IP65).

Mounting Orientation: Vertical.

Fail-safe: 3 min delay before transmission of an error signal.

Memory: Non-volatile.

Display: 4 digit LCD.

Units: ft, m (optional).

Programming: 4 button.

Weight: 3.1 lb (1.4 kg).

4-7/32[107.0]

2˝ NPT

2-5/32[55.0]

2-9/16[65.0]

1 [25.1]

7-5/8[194.0]

13/32[10.0]

35°

1/2˝ NPT

1-3/16[30.0]

1-15/32[37.0]

3-3/4[95.0]

Description

Ultrasonic Level Transmitter

Ultrasonic Level Transmitter

Model

ULL-1KFN

ULL-2KFN

SeriesULL Ultrasonic Level Transmitter for Liquids

Integrated LCD Display, Non-Contact Level Sensing, Automatic Temperature Compensation

Ne

w P

rod

uc

tsNPB-42

Price

$897.50b

897.50b

b Items are subject to Schedule B discounts.

Max. Range

16.4 ft (5 m)

49.2 ft (15 m)

Page 29: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

27

ModelULTM Ultrasonic Level Transmitter - Mobile

SMS Capability, Can Be Externally Battery Powered

Model ULTM is a level transmitter with embedded cellular communications. This productis fit for any site where SMS is available and features flexibility for customized alerts andreports. It features a cellular (GSM) link for transmission of measured data, supportingSMS and GPRS, as well as a USB for quick set up and local monitoring. The Model ULTMprovides periodic reports on the hour, and SMS reports to assigned personnel on demand.There are no on-going fees for this model’s control software due to complete data ownership.It houses an embedded, as well as an optional external temperature sensor, making it idealfor situations where rapid temperature variations may occur. The Model ULTM is a cost-effective solution perfect for remote monitoring in applications such as fuel theft detectionand river flood alerts.

APPLICATIONS

Model ULTM is ideal for managing fuel tanks at remote sites for various uses such

as fuel theft and leakage detection, inaccurate refueling, and continuous inventory

with the use of the programmable switch tracking. Due to its low power option with

the use of external battery, it features a long battery life based operation. The Model

ULTM can be useful for wastewater monitoring, 24/7 monitoring of sewer junctions,

and identification of overflow or blockage. The Model ULTM requires no road digging

and is fit for harsh weather conditions, making installation simple in a variety of

locations.

Note:

• Does not include SIM card or any cellular package.

• Works with AT&T and T-Mobile SIM cards in the U.S. Please make sure it will work

will your cellular carrier before purchasing.

• Must be a mini-SIM card.

SPECIFICATIONS

Service: Compatible solids and liquids.

Wetted Materials: PVDF.

Range:

Liquids: 26.25´ (8 m);

Solids: 19.69´ (6 m).

Accuracy: ±0.5 cm (±0.2˝) or 0.2% of max. range.

Repeatability: 0.2% of measured range.

Resolution: 0.04˝ (1 mm).

Blind Zone: 5.91˝ (15 cm).

Beam Angle: 5° @ 3 db point.

Temperature Limits: -4 to 158°F (-20 to 70°C).

Temperature Compensation: Automatic.

Power Requirements: 8 to 33 VDC.

Current Consumption:

Continuous: 10 mA @ 24 VDC;

SMS Transmission: 40 mA @ 24 VDC;

Switch Output: 160 mA @ 24 VDC.

Process Tracking Rate (max.): 0.55 ft/s (10 m/min).

Electrical Connections: Screw terminal.

Conduit Connections: 1/2˝ female NPT.

Process Connections: 1-1/2˝ male NPT, 1-1/2˝ BSP optional.

Enclosure Material: Plastic PC/ABS+UV.

Enclosure Rating: IP65/IP67, IP68 (96 hours at 5.91’ (1.8 m) water depth).

Mounting Orientation: Vertical.

Memory: Non-volatile.

Display: 64 x 128 graphic LCD.

Units: m, m/min, °F or °C (selectable).

Programming: 4-button.

Weight: 1.95 lb (884.51 g).

CELLULAR MODEM

Band: Quad band 850/900/1800/1900 mHz.

Output Power: Class 4 (33 dBm) for EGSM850/EGSM900; Class 1 (30 dBm) for

GSM180/GSM1900.

SMS: Point-to-point MO and MT.

GPRS: Multi-slot class 10.

Reports Display: Level, volume, temperature.

SMS Resolution: 0.04˝ (1 mm).

Report Type: Empty, full, theft alert, refilling alert and periodic report.

Accuracy:

0.5 to 2´ (0.15 to 0.6 m): ±0.6˝ (±1.5 mm);

2 to 16.5´ (0.6 to 5 m): ±0.3% of measured range;

16.5 to 26.25´ (5 to 8 m): ±0.2% of max. range.

5-13/32[137.45]

2-59/64[74.04]

1-1/2˝ NPT

10-61/64[278.27]

2 X 1/2˝ NPTCABLE GLANDS

4-1/8[104.75]

Series ULTMUltrasonic Level Transmitter Mobile

Temperature rating: -2 to 70°C (-4 to 158°F)Power Supply: 8-33 VDC

Enclosure Rating: IP68

Model: ULTM-H

Serial No: X XX XX XMade in: ISRAELDC: WW/YYYY

Ne

w P

rod

uc

ts

CALL TO ORDER | 800/872-9141

NPB-42

Model ULTM-00, Level Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$1260.00b

ACCESSORIES*

ULTM-EXT, External Thermistor, NTC 10KΩ 5% . . . . . . . . . . . . . . . . . . . . .$39.65b

ULTM-PTS, Programmable Timer Switch . . . . . . . . . . . . . . . . . . . . . . . . . .243.00b

*ULTM-00 only supports one accessory at a time. External battery not included.

b Items are subject to Schedule B discounts.

Page 30: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

DWYER INSTRUMENTS, INC. | www.dwyer-inst.com28

SeriesUTC Ultrasonic Liquid Transmitter & Controller

No Moving Parts, 5 Independent SPDT Relays, Liquid Level & Flow In One

Series UTC Ultrasonic Liquid Transmitter Controller provides reliable, accurate,non-contact measurement of liquid level and open channel flow even under extremely harshconditions. Overcoming vapors, agitators or light foam, with no moving parts to wear orjam. It supports a full range of process monitoring and storage level measurementapplications, such as high process tanks and large storage vessels. The UTC has a 6-digitLCD display and a simple menu structure with multiple indications, making programmingsimple. Its dual part system allows for the control unit to be located up to 656 ft (200 m)away from sensor (model UTS purchased separately), and installation is simple withincluded mounting bracket. In addition, this series also supports the Modbus RTU*communication protocol, and offers RS-232 and 4 to 20 mA communications. Featuring fiveindependent SPDT relays and embedded firmware for volume and flow totalization, thisseries is perfect for liquid level and open channel flow applications.

*Controller only, Series UTS sensor must be purchased in conjuction.

Controller UTC-1XX-XXXX-X compatible with sensor UTS-1XX-XXXX-X only, and

controller UTC-2XX-XXXX-X compatible with sensor UTS-2XX-XXXX-X only.

*UTC-1XX-XXX-X modbus read only

SPECIFICATIONS

Ranges: (Series UTS Sensor Dependent) 2 to 82 ft (0.6 to 25 m).

Accuracy: 0.25% of max. range.

Resolution: 0.04˝ (1 mm).

Temperature Limits: UTC-XXX-1XX-X: -40 to 140°F (-40 to 60°C); UTC-XXX-

2XX-X: -4 to 140°F (-20 to 60°C).

Temperature Compensation: Automatic.

Power Requirement: UTC-XXX-1XX-X: 18 to 30 VDC 6 W; UTC-XXX-2XX-X:

100 to 240 VAC 50/60 Hz.

Switch Type: 5 SPDT relays.

Electrical Rating: 1 A @ 300 VAC, 1 A @ 150 VDC.

Output Signal: 4 to 20 mA.

Max. Loop Resistance: 750 Ω @ 24 VDC.

Electrical Connections: Screw terminal.

Conduit Connection: 1/2˝ female NPT, M20 x 2.5 (optional).

Enclosure Material: ECTFE.

Enclosure Rating: NEMA 4X (IP65).

Mounting Orientation: Vertical.

Memory: Non-volatile.

Display: LCD (6 digit).

Units: m, in, ft, m3/hr, GPM interchangeable.

Programming: 4 button.

Weight: (3.5 lb) 1.6 kg.

3-11/64[80.57]

3-5/16[84.14]

6-5/32[156.37]

9-11/16[246.06]

7-51/64[198.04]

2-19/64[58.34]

3-5/32[80.17]

2-1/64[51.20]

6-7/64[155.18]

7-17/32[191.29]

2-7/8[73.03]

3-9/32[83.34]

Model

UTC-111-111-1

UTC-111-211-1

Model UTS Ultrasonic Level Transmitter Sensor is a series of sensors made toaccompany Dwyer Instrument, Inc.’s Series UTC Ultrasonic Level Controllers. This serieshas two different transducer frequencies, and a variety of measuring lengths and materials.

SPECIFICATIONS

Service: Compatible liquids.

Wetted Materials: Polypropylene.

Range: 2 to 82 ft (0.6 to 25 m).

Blind Zone: 2 ft (0.6 m).

Beam Width: 3˝ (7.6 cm) diameter.

Beam Angle: 5° @ 3 db point.

Temperature Limits: -40 to 176°F (-40

to 80°C).

Temperature Compensation:

Automatic.

Pressure Limits: Atmospheric.

Transducer Frequency: 25 kHz.

Process Connection: 2˝ male NPT, 2˝

male BSP (optional).

Electrical Connection: 16.4´ (5 m) 5

conductor 0.75 mm2 cable.

Enclosure Rating: NEMA 4 (IP65);

Weight: (3.5 lb) 1.6 kg.

2˝ NPT OR BSP

2-3/16[55.56]

4-21/64[109.93]

1˝ NPT OR BSP

Model

UTS-121-1102-1

ModelUTS Ultrasonic Liquid Transmitter Sensor

Compatible with Series UTC, 25 kHz Sensor

Ne

w P

rod

uc

ts

b Items are subject to Schedule B discounts.

b Items are subject to Schedule B discounts.

NPB-42

Description

18 to 30 VDC Power Requirement, RS-232

100 to 240 VAC Power Requirement, RS-232

Price

$1522.00b

1601.00b

Description

25 kHz Sensor, Polypropylene, Standard Range,

2 ˝ NPT Connection, 50 ft (15 m) Cable

Price

$417.00b

Page 31: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

29

The Series 861H Hazardous Rated Solid State Relay provides reliable switching andlong life operation in some of the most demanding applications, such as medical equipment,mining, oil and gas. It integrates an internal heat sink and internal snubber into a compacthousing to save space in the panel. In order to reduce installation time, integral tabs canbe used to snap the relay onto a DIN rail or surface mount to a wall inside the panel. LEDindicator lights give the user quick visual indication of the switch status. The 861H isintrinsically safe rated for Class 1, Division 2 Groups A, B, C and D.

11/16[17.60]

3-41/64[92.40]

9/16[14.30]

1-13/32[35.60]

9/64[3.40]

1-23/64[34.60] 5/8

[16.00]

3-35/64[90.00]

2-5/8[66.80]1-25/32

[45.30]

2-9/16 [65.00]

Caution!High Tem

perature

861HSSRXXX-XX-XINPUT: (VOLTAGE)

INPUT

24-280 VAC

OUTPUT

10A

(VOLTAGE)

861HSSRXXX-XX-X

CERTIFIED FORCLASS 1DIVISION 2HAZARDOUSLOCATIONSGROUPS 1, B, C, &

DPatent Pending

#14

AWG

COPP

ER W

IRE

MAX

IMUM

RATE

D AT

75°

C7.

1 lb

-in T

ORQU

E M

AXIM

UM

DIN

RAIL

Dera

ting

Dera

ting

SPECIFICATIONS

Load Voltage Range: 24 to 600 VAC; 3 to 150 VDC.

Sensor Current: 15 A max.

Electrical Connection: Screw terminals.

Switching Operation: SPST normally open.

Switching Type:

DD: DC switching;

AC/DC: Zero cross.

Temperature Limits:

Storage: -22 to 176°F (-30 to 80°C);

Operation: -40 to 212°F (-40 to 100°C).

Voltage Loss: 1.6 VDC max.

Output Leakage Current: 10 mA max.

Housing: Polycarbonate.

Hazardous Classification: Class 1 Division 2; Hazardous Locations: Groups A,

B, C and D.

Weight: 4.1 oz (127.1 g).

Agency Approvals: RoHS, UR, URc.

RoHS

Series861H Hazardous Rated Solid State Relays

15 Amp Rating, SPST-NO, Internal Heat Sink

AC Operated

Model

861HSSR210-AC-1

DC Operated

Model

861HSSR115-DD

861HSSR210-DC-1

Input Voltage Range

90 to 280 VAC

Input Voltage Range

3.5 to 32 VDC

3 to 32 VDC

The Model ANE-1 Differential Pressure Anemometer is a robust and durable bi-directional anemometer with no moving parts or sensing electronics. With the installedtubing, the ANE-1 connects easily to any manometer or applicable pressure sensing deviceand is capable of measuring a wide velocity range. The air velocity range and accuracy isdependent on the installed manometer, and the ANE-1 retains the accuracy as long as it isdust free. The ANE-1 is made from high quality ABS plastic, comes with a convenienthandle, and includes 5´ of blue and 5´of red silicone tubing (2 mm ID x 4.5 mm OD) withremoveable adapter sized 2 mm OD to 3/16˝ OD that has two removeable 5˝ clear silicone3/16˝ ID x 3/8˝ OD tubing versatile process options.

SPECIFICATIONS:

Service: Clean air only.

Wetted Materials: Anemometer: ABS; Tubing: Silicone; Handle: Phenolic.

Dimensions:

Tubing: 2 mm ID x 4.5 mm OD;

Adapter: 2 mm OD to 3/16˝ OD connections.

Temperature Limits: 23 to 122°F (-5 to 50°C).

K-Factor: 0.843.

Process Connections: 2 removeable 5˝ (12.7 cm) tubing 3/16˝ ID.

Weight: 7.7 oz (220 g).

ModelANE-1 ANE Differential Pressure Anemometer

Bi-Directional Anemometer, No Sensing Electronics

1-37/64[39.97]

11/16[17.50]

63/64[25.00]

4-9/64[105.00]

MALE M10CONNECTION

6-1/4[158.79]

10-25/64[263.79]

FEMALE M10CONNECTIONFOR HANDLE

4-23/64[110.90]

TUBING HOLE

2[50.80]

2-1/8[54.05]

HOLES FORAIR INTAKE

Ø4-23/64[110.90]

HANDLETubing Adapter

Ne

w P

rod

uc

ts

CALL TO ORDER | 800/872-9141

NPB-42

b Items are subject to Schedule B discounts.

Rated Current Load

10 amp

Rated Current Load

15 amp

10 amp

Price

$87.00b

Price

$85.00b

86.00b

Model ANE-1, Differential Pressure Anemometer . . . . . . . . . . . . . . . . . .$260.00b

b Items are subject to Schedule B discounts.

Page 32: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

DWYER INSTRUMENTS, INC. | www.dwyer-inst.com30

Thermo-Hygrometer PenMeasures Temperature, Humidity, Dew Point, Heat Index and Wet Bulb

The Model TH2-10 Thermo-Hygrometer Pen is a compact handheld device thatmeasures temperature, humidity, dew point, wet bulb, and heat index. The TH2-10 has manyapplications including HVAC, home inspection for examining heating or cooling conditions,outdoor weather monitoring, and construction or industrial inspection. This product offersfahrenheit and celsius units, data hold function, and 0.1°F/°C resolution. Batteries areincluded.

SPECIFICATIONS

Range: RH: 0 to 99.99%; Temperature: -4 to 122°F (-20 to 50°C).

Accuracy: ±3% @ 25°C/10 to 90% RH (±5% @ 0 to 10%, 90 to 100%) ±1°F

(0.6°C).

Display: 4-digit LCD.

Resolution: 0.1°F/°C.

Power Requirements: 3 V CR2032 Lithium metal battery included, user

replaceable.

Weight: 3.2 oz (91 g).

Agency Approvals: CE.

1-3/8[35.05]

5-9/16[141.38]

45/64[18.01]

2-5/8[65.34]

2-5/8[65.34]

2[52.32]

2[52.32]

BATTERY COMPARTMENT TH2-10

33% SALT SOLUTIONSALT SOLUTON KITTH2-CAL

75% SALT SOLUTION

15ºC20ºC25ºC30ºC35ºC

15ºC20ºC25ºC30ºC35ºC

xxxx±xxxxxxx±xxxxxxx±xxxxxxx±xxxxxxx±xxx

Made in xxxx

33%RH MgclSat. salt solutionTemp. Mgcl

75%RH MgclSat. salt solutionTemp. Mgcl

xxxx±xxxxxxx±xxxxxxx±xxxxxxx±xxxxxxx±xxx

Made in xxxx

S/N: xxxxxxxx

Battery:

Made in xxxxxx

AAA (UM-4)CR2032gVoltage

Thermo-Hygrometer

Power Hold Mode

(HI. WBGT TH2-10)

ModelTH2-10

The Series TP2 Thermocouple Thermometers can accurately measure a largetemperature range for a wide range of applications including food, safety inspection, labtesting, and HVAC. This hand-held thermometer offers three models that measure the probetemperature, ambient temperature, and relative humidity. Additional features include adata hold function, high/low audible alarm, and auto power off. Device includes a K typeprobe and battery.

SPECIFICATIONS

Range:

K: -328 to 2372°F (-200 to 1300°C);

J: -202 to 1652°F (-130 to 900°C);

T: -328 to 662°F (-200 to 350°C).

Accuracy:

K: ±0.3% of reading + 1°C;

J/T: ±0.1% of reading + 0.7°C.

Display: 4 digit LCD.

Resolution:

K: 0.1°F/C: -328 to 1202°F (-200 to 650°C); 2°F/1°C (others);

Over 1000°C 1°F/C.

J: 0.1°F/C: -202 to 932°F (-130 to 500°C); 2°F/1°C (others);

T: 0.1°F/C: -328 to 662°F (-200 to 350°C).

Temperature Limits: Ambient -4 to 122°F (-20 to 50°C).

Power Requirements: 3 V CR2032 Lithium metal battery included, user

replaceable.

Weight: 3.2 oz (91 g).

Agency Approvals: CE.

Model

TP2-10

TP2-20

TP2-30

Thermocouple

Input

J/K/T

J/K/T

K

Thermocouple ThermometerJ/K/T Type Thermocouple Inputs; Ambient Temperature and RH

SeriesTP2

5[127.00]

1-27/64[36.30]

45/64[18.01]

15/16[23.91]

Ne

w P

rod

uc

tsNPB-42

b Items are subject to Schedule B discounts.

Model TH2-10, Thermo-Hygrometer Pen . . . . . . . . . . . . . . . . . . . . . . . . .$50.00b

ACCESSORY

Series TH2-CAL, 33% and 75% RH Salt Bath Calibration Standards . . .$60.00n

n Items are net priced and are not subject to any discount.

Ambient Temperature/Relative Humidity

None

Ambient Temperature

Ambient Temperature and Relative Humidity

Price

$40.00b

45.00b

55.00b

b Items are subject to Schedule B discounts.

ACCESSORIES

1818-0074, Immersion probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36.50b

1818-0078, Penetration probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46.50b

1818-0082, Surface probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103.00b

1818-0085, Air duct probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79.50b

1718-0077, Remote probe handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75.00b

Page 33: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

31

Retractable Needle ThermometerFolding Stainless Steel Probe, Ambient Temperature, 0.1° C/F

The Model WT2-10 Stainless Steel Needle Thermometer provides accuratemeasurements for testing internal temperatures during food safety inspections. Aretractable penetration probe automatically shuts off the meter when closed, as well asprotects the user from the sharp tip while not in use. Additional features include minimumand maximum readings, audible and visual alarms, and a measurement hold function.Besides the probe temperature, the Model WT2-10 also measures the ambient airtemperature.

SPECIFICATIONS

Range: -40 to 302°F (-40 to 150°C).

Accuracy: ±1°F @ -4 to 248°F (1°C @ -19.99 to 119.9°C); ±2°F/C (others).

Temperature Limits: Ambient: -4 to 122°F (-20 to 50°C).

Display: 4 digit LCD.

Resolution: 0.1° F/C.

Power Requirements: 3 V CR2032 Lithium metal battery included, user

replaceable.

Sensor: Thermistor.

Probe Diameter: 0.19˝ (4.8 mm).

Enclosure Rating: IP54.

Weight: 3.2 oz (91 g).

Agency Approvals: CE.

5-55/64[148.87]

3-15/16[100.00]

3/16[4.80]

45/64[18.01]

1-31/32[50.02]

BATTERYCOMPARTMENT

NEEDLE THERMOMETER

WT2-10

MODEHOLDMX/MI/AT

ModelWT2-10

The Series MST-01 Digital Moisture Meter is a high accuracy instrument used fordetermining the moisture content in wood, gypsum, bamboo, paper and other variousmaterials. This unit features a durable and rugged enclosure which ensures a long lifespan. The large digital LCD makes measurements easy to read, while the hold functionmakes them easy to record. The MST-01 includes a nylon carrying case, protective cap,two replacement pins and battery.

SPECIFICATIONS

Range: 2 to 70% moisture content.

Accuracy: ±1.5% moisture content.

Temperature Limits: 32 to 104°F (0 to 40°C).

Humidity Limits: 0 to 70%.

Display: 3-digit LCD.

Resolution: 0.5%.

Power Requirements: 9 V alkaline battery, included, user replaceable.

Weight: 4.1 oz (116 g).

4 METALPROBES

5-3/64[128.01]

2-29/64[62.49]

1-17/64[32.31]

BATTERYCOMPARTMENT

MOISTURE METERMOISTURE METER

MST-01 MST-01

Digital Moisture MeterMeasures Moisture from 2 to 70% with High Accuracy (1.5%)

ModelMST-01

Ne

w P

rod

uc

ts

CALL TO ORDER | 800/872-9141

NPB-42

b Items are subject to Schedule B discounts.

Model WT2-10, Retractable Needle Thermometer . . . . . . . . . . . . . . . . . . $50.00b

Model MST-01, Digital Moisture Meter . . . . . . . . . . . . . . . . . . . . . . . . . . .$45.00b

b Items are subject to Schedule B discounts.

Page 34: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

DWYER INSTRUMENTS, INC. | www.dwyer-inst.com32

The Model WSM-10 Salinity Testing Pen can measure salt concentration of saltwateraquariums, determine the suitability of drinking water, and be used for ecologicalmonitoring of aquatic habitats. This pocket sized tester is constructed of a durable ABSplastic waterproof housing and 316 SS electrodes to protect against corrosion. A large LCDdisplay is easy to read and shows both the salinity and temperature measurementssimultaneously. Since change in temperature can affect accuracy, the WSM-10 hasautomatic temperature compensation to achieve ±1% accuracy. Batteries are included.

SPECIFICATIONS

Wetted Materials: ABS plastic and 316 SS.

Range: 0 to 10 ppt (NaCl) or 10.1 to 70 ppt (NaCl).

Accuracy: ±1% FS.

Display: 30(H) x 18(W) mm LCD dual display.

Resolution: .01 ppt or .1 ppt for 0 to 10 ppt range and 10 to 70 ppt range

respectively.

Temperature Limits: 32 to 122°F (0 to 50°C).

Power Requirements: (4) 1.5 V LR44 alkaline batteries, installed functional, user

replaceable.

Enclosure Material: ABS.

Enclosure Rating: IP65.

Weight: 4.3 oz (115 g).

Agency Approval: CE.

ModelWSM-10 Waterproof Salinity Testing Pen

Temperature and Salinity; ±1% FS Accuracy

6-11/32[161.21]

LCD SCREEN

1-31/64[37.80]

The Series WPH2 pH Testing Pen accurately monitors pH and temperature levels ina variety of applications. This pocket-sized tester is ideal for pH level measurements in labenvironments, industrial plants, or field environmental testing. It features an easy to replaceelectrode and automatically recognizes up to 3 calibration buffer solution ranges. Both pHand temperature, in both English and Metric units, appear on the large dual display. Boththe electrode and battery compartment caps are sealed to provide an IP65 weatherproofrating.

SPECIFICATIONS

Range: pH: 0 to 14; Temperature: 32 to 122 F (0 to 50 C).

Accuracy: WPH2-10: ±0.2 pH, ±1°C, WHP2-20: ±0.05 pH, ±0.5°C.

Display: 30 mm H x 18 mm W LCD dual display.

Resolution: WPH2-10: 0.1 pH, 0.1°C/°F, WPH2-20: 0.01 pH, 0.1°C/°F.

Operating Temperature Limits: 32 to 122°F (0 to 50°C).

Storage: 32 to 140°F (0 to 60°C).

Humidity Storage Limits: <90%.

Power Requirements: (4) 1.5 V LR44 alkaline batteries, included, user

replaceable.

Calibration: One touch auto-calibration up to 3 points.

Enclosure Rating: IP65.

Electrode: Detachable single junction, KCl filled glass.

Weight: 3.9 oz (110 g).

Agency Approval: CE.

Model

WPH2-10

WPH2-20

pH Ranges

0 to 14

0 to 14

pH Accuracy

±.2

±.05

LCD SCREEN6-59/64[176.00]

1-17/32[39.00]

SeriesWPH2 Waterproof pH Testing Pen

pH and Temperature, Waterproof Large Display

Ne

w P

rod

uc

tsNPB-42

ACCESSORY

Model WSM-10, Salinity Testing Pen . . . . . . . . . . . . . . . . . . . . . . . . . . . . .$65.00b

b Items are subject to Schedule B discounts.

ACCESSORY

WPH2-RS, Replaceable Single Junction Sensor . . . . . . . . . . . . . . . . . . . .$35.00b

pH Resolution

.1

.01

Price

$60.00b

70.00b

b Items are subject to Schedule B discounts.

Page 35: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

33

Waterproof Conductivity Testing PenConductivity and Temperature, High Resolution and Accuracy

ModelEC2-10

The Model EC2-10 Conductivity Testing Pen can monitor conductivity levels bydetermining the resistance between the electrodes. Conductivity of water is useful inmonitoring the quality of public drinking water and deionized water for industrialapplications. This pocket sized tester is constructed of a durable ABS plastic waterproofhousing and 316 SS electrodes to protect against corrosion. A large LCD display is easy toread and shows both the conductivity and temperature measurements simultaneously.Since change in temperature can affect accuracy, the EC2-10 has automatic temperaturecompensation. Batteries are included in packaging.

SPECIFICATIONS

Wetted Materials: ABS plastic and 316 SS.

Range: 0 to 1999 μS or 0 to 19.99 mS.

Accuracy: ±1% FS.

Display: 30 mm H x 18 mm W LCD dual display.

Resolution: 1uS or .01 mS.

Temperature Limits: 32 to 122°F (0 to 50°C).

Power Requirements: (4) 1.5 V LR44 alkaline batteries, installed functional, user

replaceable.

Enclosure Material: ABS.

Enclosure Rating: IP65.

Weight: 4.3 oz (115 g).

Agency Approval: CE.

6-11/32[161.21]

LCD SCREENS

1-31/64[37.80]

Waterproof Conductivity/TDS Testing PenConductivity and TDS; ±1% FS Accuracy

ModelTDS2-10

The Model TDS2-10 Conductivity/TDS Testing Pen monitors both conductivity andtotal dissolved solids in streams, rivers, or any other body of water. It picks up impuritiesand dissolved solids while checking the conductivity at the same time. This pocket sizedtester is constructed of a durable ABS plastic waterproof housing and 316 SS electrodes toprotect against corrosion. A large LCD display is easy to read and shows both theconductivity/total dissolved solids and temperature measurements simultaneously. Sincechange in temperature can affect accuracy, the TDS2-10 has automatic temperaturecompensation. Batteries included in packaging.

SPECIFICATIONS

Wetted Materials: ABS plastic and 316 SS.

Range:

Conductivity: 0 to 1999 uS or 0 to 19.99 mS;

TDS: 0 to 1999 ppm or 0 to 19.99 ppt.

Accuracy: ±1% FS.

Display: 30 mm H x 18 mm W LCD dual display.

Resolution:

Conductivity: 1uS or .01 mS;

TDS: 1 ppm or .01 ppt.

Temperature Limits: 32 to 122°F (0 to 50°C).

Power Requirements: (4) 1.5 V LR44 alkaline batteries, installed functional, user

replaceable.

Enclosure Material: ABS.

Enclosure Rating: IP65.

Weight: 4.3 oz (115 g).

Agency Approval: CE.

LCD SCREEN

1-31/64[37.80]

6-11/32[161.21]

Ne

w P

rod

uc

ts

CALL TO ORDER | 800/872-9141

NPB-42

ACCESSORY

Model EC2-10, Conductivity Testing Pen . . . . . . . . . . . . . . . . . . . . . . . . .$60.00b

b Items are subject to Schedule B discounts.

Model TDS2-10, Cond./TDS Testing Pen . . . . . . . . . . . . . . . . . . . . . . . . .$65.00b

b Items are subject to Schedule B discounts.

Page 36: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

INTERNATIONAL CUSTOMERSDwyer has local distributors in over 50 countries. Contact the office of your country or contact the corporate headquarters to

find your local distributor. You can also go to our website at the following address to be contacted by your local distributor:

http://www.dwyer-inst.com/Distributors/DistContactInfo.cfm.

Corporate Headquarters

DWYER INSTRUMENTS, INC.102 Indiana Highway 212,

P.O. Box 373

Michigan City, IN 46360, U.S.A.

PHONE FAX

219/879-8000 219/872-9057

United Kingdom

DWYER INSTRUMENTS LTDUnit 16, The Wye Estate, London Road

High Wycombe, Bucks HP11 1LH-U.K.

PHONE FAX

(+44) (0) 1494 461707 (+44) (0) 1494 465102

Australia

DWYER INSTRUMENTS, PTY. LTD.Unit 1, 11 Waverley Drive

Unanderra, NSW 2526 Australia

PHONE FAX

(+61) (0) 2 4272 2055 (+61) (0) 2 4272 4055

Hong Kong

DWYER INSTRUMENTS HK, LTD.Unit 605A, 6/F, Shui Hing Centre

13 Sheung Yuet Road, Kowloon Bay, Hong Kong

PHONE FAX

+852-23181007 +852-27561565

TECHNICAL SUPPORT

[email protected]

LITERATURE REQUESTS

[email protected]

QUOTATION/BID RE-

QUESTS

[email protected]

GENERAL INFORMATION

[email protected]

PHONEIn the U.S. call toll free:

800/872-9141

Outside the U.S. call:

219/879-8000

FAX219/872-9057

[email protected]

WEBSITEwww.dwyer-inst.com Dwyer Instruments, Inc. - Standard Terms and Conditions of Sale

1. Prices and Specifications are subject to change without notice.

2. Shipping dates are approximate. They are dependent upon credit approval and subject to delays beyond our control.

3. Terms: Net 30 days to companies with established credit rating. In the event Buyer fails to fulfill previous terms of payment, orin case Seller shall have any doubt at any time as to Buyer’s financial responsibility, Seller may decline to make further deliveriesexcept upon receipt of cash in advance or other special arrangements.

4. Liability Point and Title: All material is sold EXW Ex Works Dwyer Instruments, Inc. Title to all material sold shall pass to buyerupon delivery by Seller to carrier at shipping point.

5. State and Local Taxes: Any taxes which the Seller may be required to pay or collect upon or with respect to the sale, purchase,delivery, use or consumption of any of the material covered hereby shall be for the account of the Buyer and shall be added to thepurchase price.

6. Special tooling, dies, silk screens and molds acquired specially to produce goods for Buyer remain the property of Dwyer In-struments, Inc., and may not be removed. They will be maintained in good condition for a minimum period of three years from thedate of the original purchase order.

7. Export Orders: Terms, discounts and conditions of sale for purchase orders originating or for shipment to final destinations out-side the U.S.A. will be furnished upon request.

8. Limited Warranty: The Seller warrants all Dwyer instruments and equipment to be free from defects in workmanship or mate-rial under normal use and service for a period of one year from date of shipment. Liability under this warranty is limited to repair orreplacement EXW Ex Works Dwyer Instruments, Inc of any parts which prove to be defective within that time or repayment of thepurchase price at the Seller’s option provided the instruments have been returned, transportation prepaid, within one year from dateof purchase. All technical advice, recommendations and services are based on technical data and information which the Seller be-lieves to be reliable and are intended for use by persons having skill and knowledge of the business, at their own discretion. In nocase is Seller liable beyond replacement of equipment EXW Ex Works Dwyer Instruments, Inc or the full purchase price. This war-ranty does not apply if the maximum ratings label is removed or if the instrument or equipment is abused, altered, used at ratingsabove the maximum specified, or otherwise misused in any way.

THIS EXPRESS LIMITED WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER REPRESENTATIONS MADE BY ADVER-TISEMENTS OR BY AGENTS AND ALL OTHER WARRANTIES, BOTH EXPRESS AND IMPLIED. THERE ARE NO IMPLIEDWARRANTIES OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE FOR GOODS COVERED HEREUN-DER.

9. Buyer’s Remedies: THE BUYER’S EXCLUSIVE AND SOLE REMEDY ON ACCOUNT OF OR IN RESPECT TO THE FUR-NISHING OF NON-CONFORMING OR DEFECTIVE MATERIAL SHALL BE TO SECURE REPLACEMENT THEREOF AS AFORE-SAID. THE SELLER SHALL NOT IN ANY EVENT BE LIABLE FOR THE COST OF ANY LABOR EXPENDED ON ANY SUCHMATERIAL OR FOR ANY SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES TO ANYONE BY REA-SON OF THE FACT THAT IT SHALL HAVE BEEN NON-CONFORMING OR DEFECTIVE.

10. Acceptance: All orders shall be subject to the terms and conditions contained or referred to in the Seller’s quotation, ac-knowledgment, and to those listed here and to no others whatsoever. No waiver, alteration or modification of these terms and con-ditions shall be binding unless in writing and signed by an executive officer of the Seller. All orders are subject to written acceptanceby Dwyer Instruments, Inc., Michigan City, Indiana, U.S.A.

NOTE:

Each item (model, range, part number, etc.) is discountedindependently. In an order for more than one item, differ-ent items cannot be combined to earn a greater discount.

Most items are subject to STANDARD schedule at right.

Prices followed by the symbol b are subject to discountsper schedule B.

Certain items such as repairs, repair parts, EXPL and WP

housings, prices followed by the symbol n, special scaleand tag charges are priced at net and earn no discount.

INDUSTRIAL DISCOUNT SCHEDULE*

QUANTITYOF EACH

ITEM

1-24

25-99

100-249

250-499

500-Up

Net

5%

10%

15%

20%

Net

Net

5%

10%

15%

DISCOUNTS

STANDARD SCHEDULE B

*Please contact us for discount schedules for other account types.

Dwyer Instruments, Inc. - Discount Schedule

Page 37: NPB-42 - dwyer-inst.com · 2 DWYER INSTRUMENTS, INC. | TO CONTACT A TECHNICAL SUPPORT ENGINEER PHONE 219/879-8000 FAX 219/872-9057 EMAIL tech@dwyer-inst.com REAL PEOPLE Courteous

DWYER INSTRUMENTS, INC.

P.O. Box 373Michigan City, IN 46360

Return Service Requested

©Copyright 2013 Dwyer Instruments, Inc. 3/13

Printed in U.S.A.

NPB-42