Upload
tranlien
View
224
Download
1
Embed Size (px)
Citation preview
Nuclear Maintenance Management
Program
Manual
Document
Page
Issue Date
Management Plan
TFC-PLN-29, REV C-15
1 of 21
January 30, 2018
Ownership matrix
USQ # 17-1269-D
TABLE OF CONTENTS
1.0 PURPOSE AND SCOPE ................................................................................................................ 2 2.0 METHOD OF REVIEW ................................................................................................................. 2 3.0 PROGRAM ELEMENTS AS APPLIED BY WRPS ..................................................................... 3
3.1 Maintenance Organization and Administration .................................................................. 3 3.2 Master Equipment List ........................................................................................................ 3 3.3 Planning, Scheduling, and Coordination of Maintenance ................................................... 3 3.4 Types of Maintenance ......................................................................................................... 5 3.5 Maintenance Procedures ..................................................................................................... 5 3.6 Training and Qualification .................................................................................................. 6 3.7 Configuration Management ................................................................................................ 7 3.8 Procurement ........................................................................................................................ 8 3.9 Maintenance Tool and Equipment Control ......................................................................... 9 3.10 Suspect and Counterfeit Items ............................................................................................ 9 3.11 Maintenance History ......................................................................................................... 10 3.12 Aging Degradation and Technical Obsolescence ............................................................. 10 3.13 Seasonal Facility Preservation .......................................................................................... 11 3.14 Performance Measures ...................................................................................................... 11 3.15 Facility Condition Inspection ............................................................................................ 11 3.16 Post Maintenance Testing ................................................................................................. 13 3.17 Integration with Regulations and DOE Orders and Manuals ........................................... 13
4.0 SOURCES ..................................................................................................................................... 14 4.1 Requirements .................................................................................................................... 14 4.2 References ......................................................................................................................... 14
TABLE OF TABLES
Table 1. TOC Program Plans Applicable to the NMMP. .......................................................................... 18
TABLE OF ATTACHMENTS
ATTACHMENT A - MAINTENANCE PROGRAM IMPLEMENTING PLANS/PROCEDURES AND
PROCESSES .............................................................................................................................. 20
Nuclear Maintenance Management
Program
Manual
Document
Page
Issue Date
Management Plan
TFC-PLN-29, REV C-15
2 of 21
January 30, 2018
1.0 PURPOSE AND SCOPE (4.1.1, 4.1.2)
The Nuclear Maintenance Management Plan (NMMP) is established to comply with the
U.S. Department of Energy (DOE) O 433.1B, “Maintenance Management Program for DOE
Nuclear Facilities.” The NMMP describes the safety management program for maintenance and
the reliable performance of structures, systems and components (SSCs) that are part of the safety
basis required by 10 CFR 830.202 at hazard category 1, 2, and 3 Department of Energy (DOE)
nuclear facilities. The NMMP is not applicable to non-nuclear facilities (e.g., Cold Test Facility,
mobile offices, 2750E, 2704HV, and other office buildings, including those south of the Wye
Barricade).
The Nuclear Maintenance Management Plan (NMMP) provides reference to implementing
procedures/programs for each area discussed, and documents reasons for deviating from the
guidance where appropriate. Although the NMMP does not apply to non-nuclear facilities
(e.g., Cold Test Facility, mobile offices, 2750E, 2704HV, and other office buildings, including
those south of the Wye Barricade), the NMMP discusses processes such as work release that may
have application to a non-nuclear facility. Attachment A directs the reader to the appropriate
implementing procedure for each program element identified in the NMMP.
Washington River Protection Solutions, LLC (WRPS) uses a graded approach to implementing
the specific requirements of DOE O 433.1B.
Graded approach, as defined in 10 Code of Federal Regulation (CFR) Part 830, “Nuclear Safety
Management,” means the process of ensuring that the level of analysis, documentation, and
actions used to comply with a requirement in this part are commensurate with:
The safety, safeguards, and security function provided;
The magnitude of any hazard involved;
The life cycle stage of a facility;
The programmatic mission of a facility;
The particular characteristics of a facility;
The relative importance to radiological and non-radiological hazards; and
Any other relevant factor.
The NMMP is required to be submitted to the Department of Energy-Office of River Protection
(DOE-ORP) for approval every three years. Changes to the NMMP are required to be evaluated
in accordance with TFC-ENG-SB-C-03. Changes to implementing documents discussed in the
NMMP do not require DOE-ORP approval but need to be evaluated to ensure the change does not
affect the NMMP.
2.0 METHOD OF REVIEW
This document has been prepared by reviewing the 17 major elements found in DOE O 433.1B,
Attachment 2, reviewing guidance provided in the Nuclear Facility Maintenance Management
Program Guide DOE G 433-1-1A Chg 1 and evaluating the direction provided in the
implementing documents discussed in the NMMP to ensure adequate direction is provided to
demonstrate compliance with the order.
Nuclear Maintenance Management
Program
Manual
Document
Page
Issue Date
Management Plan
TFC-PLN-29, REV C-15
3 of 21
January 30, 2018
3.0 PROGRAM ELEMENTS AS APPLIED BY WRPS
3.1 Maintenance Organization and Administration
TFC-CHARTER-01 defines the organizational alignments and summary level roles and
responsibilities for the implementation of the Tank Operations Contractor (TOC) mission. The
Maintenance Organization was established as a separate group in 2015. The organizational
structure has a Maintenance Manager with four groups reporting to this position: Craft Support,
Work Control, Programs, and Contractor Assurance.
Administrative procedures/processes provide direction for the development of technical
procedures and work orders that incorporate management policies and assign responsibility for
implementation.
Administrative procedures are used to implement maintenance program requirements (e.g., lock
and tag, scaffolding use, control of Measuring and Test Equipment, use of qualified spare parts,
inspection criteria). Technical and administrative controls are specified in work instructions
developed in accordance with TFC-OPS-MAINT-C-01. The maintenance function involves
integrating activities and requirements of multiple organizations (e.g., operations, health physics,
engineering, safety) to plan, review, and execute work. The work force is involved at all levels
and in all phases of the work (planning and execution), allowing for feedback to improve safety,
reliability, quality and productivity.
TOC management uses performance indicators, system health reports, operating data, self-
assessments, and management observations to monitor various aspects of the maintenance
program.
3.2 Master Equipment List
The Master Equipment List (MEL) for the TOC is contained in SmartPlant®1 Foundation (SPF)
per TFC-ENG-FACUP-C-23. Equipment Identification Numbers (EIN) are assigned for
components of safety systems, equipment that is vital to continued operation and mission
accomplishment, equipment that is required to satisfy environment regulations, and any
equipment that requires periodic maintenance unless the periodic maintenance is managed by
contract and the maintenance is scheduled and tracked using another system (e.g., fire systems,
radiological control instrumentation, and 222-S Laboratory equipment). Equipment listed in SPF
with an EIN comprises the MEL. TFC-ENG-FACSUP-C-23 details the process for
developing, implementing, managing, and maintaining the MEL.
TFC-OPS-MAINT-C-12 provides direction for maintenance personnel in the use of the Work
Management System (WMS) and SPF to identify and apply appropriate controls to maintenance.
3.3 Planning, Scheduling, and Coordination of Maintenance
Production Operations and Single Shell Tank (SST) Retrievals ensure maintenance actions are
scheduled and closely monitored to ensure maximum equipment operability of:
SSCs
Environmental and regulatory equipment
1 SmartPlant® is a registered trademark of Intergraph, Corporation of Madison, Alabama.
Nuclear Maintenance Management
Program
Manual
Document
Page
Issue Date
Management Plan
TFC-PLN-29, REV C-15
4 of 21
January 30, 2018
Equipment necessary to support operational needs.
Production Operations, SST Retrievals, and various project managers participate in integrated
schedule meetings to establish work priorities and assign resources to support operational
evolutions, construction, and maintenance activities. Work activities are coordinated by a
detailed review of the Plan of the Week, and daily by reviewing the work plan of the day (work
release sheet). Maintenance, Operations, and supporting personnel attend the Plan of the Week
and Plan of the Day meetings to discuss resource needs and resolve any potential work conflicts.
Highest priority is assigned to correct imminent safety hazards, restore inoperable safety SSCs,
and restoration of environmental/regulatory equipment.
TFC-ENG-FACSUP-P-01 describes the system engineer program and establishes the
responsibilities of the cognizant system engineer (CSE) in accordance with DOE O 420.1C. The
CSE plays a role in the planning and prioritization of maintenance activities, in accordance with
DOE O 420.1C. In particular, the CSEs:
Ensure that system configuration is managed effectively
Remain apprised of the operational status and ongoing modification activities
Assist in review of key system parameters and evaluating system performance
Initiate actions to correct problems
Remain cognizant of system-specific maintenance and operations history, industry
operating experience, as well as manufacturer and vendor recommendations, and any
product warnings regarding safety SSCs
Identify trends from operations and maintenance associated with the safety SSCs
Provide assistance in determining operability, correcting out-of-specification conditions,
and evaluating questionable data
Provide or supporting analysis when an SSC is suspected of inoperability or degradation
Review and concur with design changes
Review, and provide input into the development of operating, maintenance, and test
procedures.
TFC-OPS-MAINT-C-01 addresses work origination, screening, work package planning,
pre-release review, work authorization/release, work instructions, and post maintenance testing.
All work in the nuclear facilities at Tank Farms and 222-S Laboratory is reviewed to ensure the
facility conditions support conducting the work safely, and that the work instructions include
appropriate steps to comply with safety basis and environmental/regulatory requirements.
TFC-OPS-MAINT-C-12 discusses management of the preventive maintenance (PM) program
and TFC-OPS-OPER-C-65 outlines the Rolling Schedule process.
Nuclear Maintenance Management
Program
Manual
Document
Page
Issue Date
Management Plan
TFC-PLN-29, REV C-15
5 of 21
January 30, 2018
3.4 Types of Maintenance
Preventive maintenance requirements (e.g., functional checks, calibrations, mechanical
inspection, cleaning) are tracked in the Computerized Maintenance Management Software
(CMMS). The goal of the PM program is to maximize equipment availability by eliminating
hidden faults before equipment is disabled. The maintenance requirements and the periodicity is
established by engineering taking into consideration the operational history of the equipment,
input from maintenance craft, technical safety requirements, vendor suggested maintenance, and
codes and standards (e.g., National Electric Code, Washington Administrative Code,
environmental regulations). Equipment not routinely used is calibrated or otherwise maintained
before use (if required). When it is determined that a PM activity is no longer required (e.g.,
equipment no longer in use), the PM activity is discontinued or inactivated in CMMS.
RPP-7574, “Double Shell Tank Integrity Program Plan,” is a comprehensive program to ensure
the continued viability of the Double-Shell Tanks (DSTs) to support the Hanford mission. The
program utilizes predictive maintenance technologies (e.g., video inspections and ultrasonic
testing) to inspect DSTs and 242-A Evaporator components. Additionally the DST Integrity
Program performs integrity testing and certification of pipelines, visual inspections of valve pits,
and hydrostatic testing of evaporator components.
TFC-ENG-FACSUP-C-23 is the administrative procedure for identifying equipment requirements
and entering them into CMMS. TFC-OPS-MAINT-C-12 is the process used to administer the
preventive maintenance program.
Work orders to complete PM activities provide work instructions with sufficient detail to identify
and mitigate potential hazards, complete the maintenance requirement, and document the results.
When out-of-tolerance/deficient conditions or unexpected results are obtained, and authorized
work steps do not restore the system/component to in-specification operating conditions, the
system/component engineer is notified. If the identified problem is not corrected, the equipment
will be taken out of service until repairs are made using a corrective maintenance work order, or
the equipment use is restricted as determined by engineering.
Corrective maintenance is prioritized by taking into account personnel safety, technical safety
requirements, environmental requirements and mission needs.
3.5 Maintenance Procedures
There are two primary procedure types used:
Operating procedures developed in accordance with TFC-OPS-OPER-C-13 provide
technical direction for manipulating systems/components and operating equipment
Work instructions contained in work packages developed using TFC-OPS-MAINT-C-01
to provide specific direction for performing maintenance work on systems/components.
TFC-OPS-OPER-C-13 establishes the minimum requirements for the TOC technical procedures.
Technical procedures are used for guidance and control of Tank Farm operations, maintenance,
surveillance, radiological control, and emergency response.
TFC-OPS-MAINT-C-01 defines work management from initiation of a work request through
work order closeout, and applies to all TOC personnel who schedule, plan, approve, release, and
perform operations acceptance or post-review using work orders.
Nuclear Maintenance Management
Program
Manual
Document
Page
Issue Date
Management Plan
TFC-PLN-29, REV C-15
6 of 21
January 30, 2018
Multiple Safety Management Programs (See Table 1) and their associated implementing
documents are involved with planning work and to incorporate environmental, nuclear safety
basis, quality assurance and industrial safety requirements. Proper integration of requirements is
essential for implementing TFC-PLN-01, “Integrated Environment, Safety, and Health
Management System Plan” as discussed in RPP-MP-003, “Integrated Environment Safety and
Health Management System Description for the TOC.” Procedures involved in planning work
include but are not limited to:
DOE-0359, “Hanford Site Electrical Safety Program”
TFC-OPS-MAINT-C-01, “Tank Operations Contractor Work Control”
TFC-ESHQ-S_SAF-C-02, “Job Hazard Analysis”
TFC-ENG-DESIGN-C-06, “Engineering Change Control”
TFC-ENG-STD-08, “Post Maintenance Testing”
TFC-ESHQ-RP_ADM-C-11, “Joint Review Group”
TFC-ESHQ-RP_RWP-C-03, “ALARA Work Planning”
TFC-ESHQ-RP_RWP-C-04, “Radiological Work Permits.”
3.6 Training and Qualification
Maintenance is performed by personnel who have completed the training requirements
established by management in accordance with DOE O 426.2, “Personnel Selection, Training,
Qualification, and Certification Requirements for DOE Nuclear Facilities.”
TFC-BSM-TQ-STD-10 describes the qualification process and training program
applicable to Instrument Specialists, Electricians, Millwrights and Pipefitters.
TFC-BSM-TQ-STD-03 describes the qualification and training program for personnel
who supervise maintenance activities and operations work.
TFC-BSM-TQ-STD-01 defines the requirements for qualifying personnel in various
technical technician and support staff positions.
Maintenance personnel are informed of changes to plant policies, procedures, systems, and
equipment by ensuring only the most recent approved procedures are used when performing an
activity; by pre-job briefings; by periodic briefings by supervisors/managers (e.g., tailgates); and,
when appropriate, by familiarization training.
Workers who can access nuclear facilities are required to meet specific requirements for
radiological workers. This training process ensures that personnel demonstrate their knowledge
of the proper use of personal protective equipment (PPE) worn to prevent personnel
contamination. This training also ensures that personnel have a basic understanding of actions to
minimize radiation exposure, and action to take in the event of degrading radiological conditions.
In addition, personnel who may be required to wear respiratory equipment receive specialized
training on each type of respirator they are authorized to use. Other training, such as the
Hazardous Waste Course, provides workers with knowledge and use of PPE for various
hazardous situations. Some craft have specialized training and PPE requirements applicable to
the hazards associated with their work.
Nuclear Maintenance Management
Program
Manual
Document
Page
Issue Date
Management Plan
TFC-PLN-29, REV C-15
7 of 21
January 30, 2018
TFC-PLN-47 discusses that the TOC has established a worker safety and health training and
information program within a training and qualification plan. Management, with input from
health and safety professionals, uses standard training profiles, coupled with the employee job
task analyses in determining: 1) training requirements based on hazards in the workplace,
2) tasks the employees will perform, 3) requirements based on worker classification (e.g., field
work supervisors, radiological worker), and 4) technical staff position qualifications (e.g., system
engineer, quality assurance engineer, operations engineer). The training organization and
management, use a web-based electronic integrated training matrix to track and ensure that all
workers exposed or potentially exposed to hazards are provided with the training and information
on that hazard in order to perform their duties in a safe and healthful manner. The program
provides training and information for new workers, before or at the time of initial assignment to a
job involving exposure to a hazard. Periodic training is provided as often as necessary to ensure
that workers are adequately trained and informed. Additional training is provided when safety
and health information or a change in workplace conditions indicates that a new or increased
hazard exists. The TOC has established a technical staff qualification plan to ensure training and
information is provided to employees who have worker safety and health program responsibilities
that is necessary for them to carry out those responsibilities.
The TOC utilizes other Hanford Prime Contractors for resources to perform work that is within
the defined scope of their respective contracts with the DOE. Examples of work performed by
other Hanford contractors include Fire System Maintenance preventive and corrective work,
Heating/Ventilation/Air Conditioning preventive and corrective work and road
maintenance/repair. The work is performed and managed through Interface Agreements, which
are developed per TFC-BSM-CP_CPR-C-17. The resources from other Hanford contractors must
meet the training requirements to perform work within the TOC.
3.7 Configuration Management
TFC-PLN-23 documents the TOC Configuration Management (CM) program that establishes
consistency among design requirements, physical configuration, and documentation (including
analysis, drawings, and procedures) for the activity, and maintains this consistency throughout the
life of the facility or activity, particularly as changes are being made.
Fulfilling the configuration management objective is accomplished through the key configuration
management elements: design requirements, work control, change control, documentation
control and assessments. The key configuration management elements are followed by all
personnel, using an integrated process when performing activities that affect SSCs. The CM
process includes policies, management plans, work practices, and procedures that are used by
WRPS and its subcontractors.
The TOC CM program is a non-credited Safety Management Program (SMP) briefly described in
TOC Safety Basis documents (RPP-13033, “Tank Farm Documented Safety Analysis”; HNF-
12125, “222-S Laboratory Documented Safety Analysis”; and HNF-14755, “242-A Evaporator
Documented Safety Analysis”). This plan is required by DOE-STD-1073, “Configuration
Management.” This standard is invoked by TFC-POL-07. The CM program is compliant with
the CM requirements of U.S. Department of Energy (DOE) Orders DOE O 420.1C, “Facility
Safety”; DOE O 413.3, “Program and Project Management for the Acquisition of Capital
Assets”; DOE O 433.1B, “Maintenance Management Program for Nuclear Facilities”; DOE O
422.1, “Conduct of Operations”; and ASME/NQA-1, “Quality Assurance Requirements for
Nuclear Facility Applications.”
Nuclear Maintenance Management
Program
Manual
Document
Page
Issue Date
Management Plan
TFC-PLN-29, REV C-15
8 of 21
January 30, 2018
3.8 Procurement
TFC-ENG-DESIGN-C-34 defines the requirements associated with the preparation, review,
approval, release, and revision of engineering/technical requirements for such items as catalog
items, developmental technology, engineered equipment, design/build procurements and
construction. It provides for simpler, alternate process for conveying engineering/technical
requirements during procurement, when the complexity of procurement does not require a
standalone specification.
TFC-ENG-DESIGN-C-15 establishes the dedication process, dedication requirements, and
related responsibilities for the use of commercial grade items as safety significant components, in
safety significant applications for Hanford TOC managed nuclear facilities. These activities are
performed to ensure that the safety functions of safety significant items are preserved (i.e., the
commercial grade item is suitable for use in its intended application and that the item will
perform its safety function) and to protect the design baseline from being inadvertently changed.
TFC-BSM-CP_CPR-C-05 defines the process for procurement planning, execution, and closeout
of subcontracted tank farm services and construction work scope.
TFC-BSM-CP_CPR-C-06 defines the process for procuring quality level materials or items
utilizing a Bill of Material (BOM) or a Material Requisition (MR). This process is used for the
procurement/acquisition of engineered equipment, materials for construction activities, corrective
and PM materials, fabricated parts or components, permanent material installations, and direct
materials (future field installations, tool crib supplies/stock, hand tools, shop stock, operations
supplies, and maintenance supplies) for WRPS.
TFC-BSM-CP_CPR-C-19 provides the process for the identification, review and approval,
procurement, and inventory management of spare parts, and spare equipment. Spare parts are
established in inventory, as appropriate, to maintain continuity of facility operations and to reduce
system and facility downtime through availability of the identified parts.
TFC-BSM-CP_CPR-C-18 outlines the processes for:
Receiving, staging, issuance, storage, handling, and return to inventory materials,
equipment, supplies, and consumables (including using the Field Bill Of Material and
Preliminary Engineering Change Notice [ECN] process to complete current field
conditions work)
Receipt, handling, storage and issuance of construction material for completed, canceled
or suspended projects
Tool Crib operation and requirements related to control of suspect/counterfeit items
(S/CIs)
Controlling convenience storage material inventory
Removal and reuse of existing parts and assemblies
Disposal of government owned equipment and surplus property.
Nuclear Maintenance Management
Program
Manual
Document
Page
Issue Date
Management Plan
TFC-PLN-29, REV C-15
9 of 21
January 30, 2018
3.9 Maintenance Tool and Equipment Control
TFC-OPS-MAINT-C-03 describes the requirements for maintaining, using, issuing, storing, and
controlling tools and equipment needed to support TOC maintenance activities.
Measuring and Test Equipment (M&TE) used to calibrate installed plant instrumentation or to
obtain data specified by Engineering is controlled in accordance with TFC-OPS-MAINT-C-07.
All M&TE used to support calibration, functional testing, and data collection is calibrated and
traceable to nationally recognized standards, and performed by a certified lab repair facility with
the specialized equipment and qualifications necessary to comply with quality assurance
requirements. In the event that a Notice of Discrepancy is received documenting a problem with
M&TE, an evaluation by Engineering is conducted to determine appropriate corrective action.
This action may require recalibration using a different piece of M&TE, or an engineering
evaluation explaining why recalibration is not necessary. The tool cribs maintain a list of M&TE.
M&TE used by the Industrial Hygienist and Radiological Controls is controlled as described
below:
TFC-PLN-64, “Industrial Hygiene Instrumentation Plan,” describes the Tank Operations
Contractor (TOC) industrial hygiene instrumentation program elements and
responsibilities for developing and implementing the program. The industrial hygiene
instrumentation program is designed to establish criteria to ensure a systematic and
methodical approach to instrument selection, use, control, calibration and maintenance.
TFC-ESHQ-RP_INS-P-05, “Radiation Protection Instrument Program,” describes the
radiation protection instrument program, defining the requirements and company-wide
practices for radiological control monitoring instrumentation and equipment.
3.10 Suspect and Counterfeit Items
TFC-ESHQ-Q_C-C-03 describes the process for the identification, prevention, evaluation,
notification, and disposition of suspect/counterfeit items (S/CIs) at WRPS. This procedure
applies to items that are:
In the procurement cycle
In receiving inspection
In inventory at warehouses and staging areas
Installed
In operation.
Nuclear Maintenance Management
Program
Manual
Document
Page
Issue Date
Management Plan
TFC-PLN-29, REV C-15
10 of 21
January 30, 2018
3.11 Maintenance History
All work orders generated in CMMS are maintained electronically and are easily retrieved. This
includes corrective and preventative maintenance, and facility modifications. The work planner
can access this information during the work planning process. The work orders provide a
description of work performed; parts that were used, inspection results, test equipment used, and
retest data. This maintenance history can be reviewed and used to develop the Quarterly System
Health Reports. System Health Reports present the concise status of the assigned system during
the most recent quarter and limited data from the previous quarter in key performance areas for
comparison. The system health report provides a tool for the system engineer and the responsible
manager to identify trends in system performance and issues that require attention. The reports
also provide management the ability to recognize emerging problems in order to ensure system
engineers and site facilities are provided the support they need. Maintenance history is
considered when scheduling operations that require special equipment (e.g., waste transfers) and
when scheduling maintenance activities that require special considerations (e.g., electrical outage
during cold weather conditions).
3.12 Aging Degradation and Technical Obsolescence
WRPS applies a graded approach to inspections/evaluations for age degradation and technical
obsolescence, placing more emphasis on those SSCs that are part of the safety basis and therefore
required to protect the work force, the public, and/or the environment.
Periodic performance of Technical Safety Requirements (TSR) Surveillance Requirements (SR)
and Design Feature (DF) inspections, and/or integrity assessments are used demonstrate that
equipment is capable of performing its intended safety function. Satisfactory performance of the
required TSR SR and DF inspections demonstrates that the safety SSCs can perform their
intended safety function. However, these TSR required actions (SR and DF inspections) may
also reveal deteriorated safety SSCs including deterioration associated with aging. Technical
Safety Requirements for safety SSCs are performed in accordance with approved operating
procedures or preventative maintenance work packages. TFC-OPS-OPER-C-01 describes the
actions required to ensure compliance with the TSRs to ensure execution of the operating
procedures or PM work packages associated with the various safety SSCs. Maintaining
compliance with the TSRs ensures that safety SSCs are able to meet their intended safety function
and functional requirements.
In addition, WRPS reviews the 242-A Evaporator, DSTs, and ancillary equipment that are
expected to exceed their design life. Accordingly, the DST Integrity Project (DSTIP) was
developed to ensure that the systems can meet the mission goals. RPP-7574, “Double Shell Tank
Integrity Program Plan,” provides controls and inspections that ensure system integrity is
maintained throughout the mission, including the 242-A Evaporator. DST Integrity Project
activities include the following principal elements:
242-A Evaporator and DST integrity assessments (e.g., ultrasonic and video
examinations) and documentation of results for use in periodic re-inspections
DST waste chemistry sampling and adjustments for corrosion mitigation
DST waste chemistry corrosion optimization studies to quantify the best waste chemistry
parameters to minimize DST corrosion
Nuclear Maintenance Management
Program
Manual
Document
Page
Issue Date
Management Plan
TFC-PLN-29, REV C-15
11 of 21
January 30, 2018
Development and installation of in-tank corrosion probes for DSTs with new or revised
corrosion control limits
DST structural analysis and studies for thermal, operating, and seismic loads
Periodic testing, evaluation, and certification of DST support equipment such as waste
transfer lines, valve pits, AZ-301, etc.
RPP-PLAN-45082, “Implementation Plan for the Single Shell Tank Integrity Project” provides
details of a project to ensure the integrity of the SSTs until the waste can be retrieved from the
tanks for treatment.
Safety SSCs are considered technically obsolete when those SSCs are no longer supported by the
manufacturer. Technical obsolescense of safety SSCs can be identified by activities, such as but
not limited to:
Manufacturer communication regarding their plan to discontinue support for specific
models,
Parts availability at time of purchase
Period review as described in RPP-PLAN-59958, Process & Control System Engineering
Software & Equipment Obsolescence Plan
Problem Evaluation Requests (PER) in accordance with TFC-ESHQ-Q-C-C-01
Replacements for obsolete safety SSCs is accomplished following the modification process
initiated by the Modification Traveler in accordance with procedure TFC-ENG-DESIGN-C-56.
3.13 Seasonal Facility Preservation
TFC-BSM-FPM_PR-C-13 provides seasonal facility preservation expectations, and defines the
responsibilities and requirements for implementation, surveillance, and securing from cold
weather and facility preservation during the winter months. TFC-ENG-STD-02 requires that the
design of safety SSCs includes methods to protect the SSCs from adverse weather conditions.
Engineering specifies the maintenance required to maintain these SSCs. Maintenance procedures
3-MISC-126 and 3-MISC-363 direct the winterization checks of heat trace, and freeze protection.
Operations procedures TO-040-791 and TO-040-792 direct the monitoring of temperatures for
safety SSCs.
3.14 Performance Measures
TFC-PRJ-PC-C-11 provides the method for developing, documenting, analyzing, and presenting
performance indicators, reporting analysis results, and identifying the need for corrective or
improvement actions. TOC Maintenance utilizes several performance indicators that have been
developed to monitor performance. These performance indicators are monitored and reviewed to
allow for identification of adverse trends.
3.15 Facility Condition Inspection
TFC-ESHQ-S_SAF-C-12 is the TOC procedure that integrates general worksite safety and health
inspections that are occurring on a scheduled basis into one overall inspection process.
Nuclear Maintenance Management
Program
Manual
Document
Page
Issue Date
Management Plan
TFC-PLN-29, REV C-15
12 of 21
January 30, 2018
The PM, DSTIP, and Single Shell Tank Integrity Project are integral parts of the inspection
process for SSCs at Tank Farms, these programs help to maximize equipment operability and
reliability by eliminating hidden faults before equipment is disabled, and identify actions
necessary support the RPP mission goals with existing equipment and infrastructure.
Periodic inspection of SSCs is accomplished by field walkdowns by designated engineers in
accordance with TFC-ENG-FACSUP-P-01. When system components are inaccessible,
alternative methods of system evaluation approved by engineering management are performed.
The periodic inspections/walkdowns may include reviewing system operational testing, or
evaluating remotely obtained monitoring data when appropriate. The system walkdowns address
both material conditions and compliance aspects (including TSR (Technical Safety Requirement)
level controls) and are an essential step in evaluating SSCs for degraded conditions that affect
operability and technical obsolescence. When corrective maintenance is necessary, a work order is
generated.
The Management Observation Program (MOP) (TFC-ESHQ-AP-C-03), Management-Directed
and Required Assessments (TFC-ESHQ-AP-C-01), Employee Accident Prevention Council
activities, and Radiological surveillances are all used to identify and correct industrial safety
deficiencies, radiological protection/control deficiencies, and general housekeeping deficiencies.
MOP evaluations and Management Assessments concentrate on safety practices, work habits,
radiological control practices, and work site conditions.
DOE O 430.1B, “Real Property Asset Management,” requires the performance of Condition
Assessment Surveys (CAS) to assess the current material condition of real property. For the
Hanford Site, a list of buildings/facilities to be assessed has been developed using a graded
approach as described in DOE/RL-2012-29, “Hanford Ten Year Site Plan.” The assessment
information for each assessed item is entered into the Condition Assessment Information System
(CAIS). The Mission Support Contractor (MSC) manages the Hanford Site CAS/CAIS and
provides for the administration and execution of the CAS inspection program. The TOC provides
access to facilities and assist as necessary.
Tank Farm underground storage tanks, piping systems, and associated underground systems are
not address by the CAS Program Deficiency Standards & Inspections Methods Manual. CAS
inspection of underground tank farm systems and structures are not included in the program;
however, the DST Integrity Program includes:
Periodic DST integrity assessments (e.g., ultrasonic testing and video inspection)
Chemistry sampling and adjustments for DST corrosion control
DST structural analysis
Periodic testing, evaluation, and certification of DST support equipment such as waste
transfer lines and valve pits
Periodic testing and certification of the 242-A Evaporator Facility (e.g., Cathodic
Protection).
The integrity assessment program is being expanded to include SSTs.
Nuclear Maintenance Management
Program
Manual
Document
Page
Issue Date
Management Plan
TFC-PLN-29, REV C-15
13 of 21
January 30, 2018
3.16 Post Maintenance Testing
TFC-OPS-MAINT-C-01 requires work be reviewed for post maintenance testing applicability.
The instructions for performing and documenting Post Maintenance Testing are included in the
work instructions when applicable. Post maintenance testing is performed to verify components
will fulfill their design function when returned to service after maintenance. This testing
comprises verification that the affected equipment (including interfaces, controls, interlocks, and
instrumentation) performs its intended functions following maintenance to ensure the original
deficiency was corrected and no additional deficiencies were created.
Post maintenance testing of safety SSCs is required for safety SSCs in accordance with
TFC-OPS-MAINT-C-01 and TFC-ENG-STD-08. General Service SSCs are evaluated to
determine the extent of or need for post maintenance testing. Post maintenance testing for minor
maintenance (e.g., repaint a step, or repair lagging) may not be applicable. More extensive
maintenance (rebuild an air compressor) may require a series of tests specified by the vendor or
engineering; therefore, a graded approach is applied to post maintenance tests for non-safety SSCs.
3.17 Integration with Regulations and DOE Orders and Manuals
The TOC has developed programs, policies, and procedures necessary to implement regulations,
DOE Orders and manuals that are applicable to the NMMP. Specific details of the program
requirements are found in the implementing documents applicable to the program. The following
is a brief synopsis’s of key interfaces with the NMMP that have not been previously discussed.
TFC-PLN-02 describes the quality assurance program using the structure of DOE O 414.1D:
Management Processes
Performance Processes
Assessment Processes.
Management process requirements are applied throughout the performance processes and
assessment processes as appropriate to the type of work being accomplished. Performance
process requirements specify the quality assurance controls for conducting the supporting work,
design, procurement and inspection and test activities. The performance process requirements are
applied to items and services. Assessment process requirements provide the oversight processes
utilized in the monitoring of all quality process activities. The assessment process requirements
include management assessment, audit, and surveillance. The assessment processes assure that
the WRPS, subcontractors, and suppliers comply with the quality assurance requirements.
TFC-PLN-41 describes the integrated processes established to perform the five core functions and
seven guiding principles of the Integrated Safety Management System (ISMS), contained in 48
CFR 970.5223-1, “Integration of Environment, Safety, and Health into Work Planning and
Execution.” It describes the methods used to establish, document, and implement safety
performance objectives, performance measures, and commitments in response to DOE program
and budget execution guidance while maintaining the integrity of ISMS.
TFC-PLN-10 describes the framework of the Tank Operations Contractor (TOC) assessment
processes for implementing the Assessment Program. The Assessment Program is an essential
part of Integrated Environment, Safety, and Health Management System (ISMS) core function 5 -
“Feedback and Continuous Improvement.”
Nuclear Maintenance Management
Program
Manual
Document
Page
Issue Date
Management Plan
TFC-PLN-29, REV C-15
14 of 21
January 30, 2018
4.0 SOURCES
4.1 Requirements
1. 10 CFR 851, “Worker Safety and Health Program,” 10 CFR 851.21 (a)(5) and (a)(6).
2. DOE O 433.1B, “Maintenance Management Program for DOE Nuclear Facilities.”
4.2 References
1. 3-MISC-126, “Tank Farms Weekly Check of Heater and Heat Trace.”
2. 3-MISC-363, “Winterization/De-Winterization Tank Farms.”
3. 10 CFR 830.3, “Definitions.”
4. 48 CFR 970.5223-1, “Integration of Environment, Safety, and Health into Work Planning
and Execution.”
5. ASME/NQA-1, “Quality Assurance Requirements for Nuclear Facility Applications.”
6. ATS-310, Section 3.18, “Instrument Calibration.”
7. DOE G 433.1-1A, “Nuclear Facility Maintenance Management Program Guide.”
8. DOE O 413.3, “Program and Project Management for the Acquisition of Capital Assets.”
9. DOE O 420.1C, “Facility Safety.”
10. DOE O 422.1 Chg 2 “Conduct of Operations.”
11. DOE O 426.2, “Personnel Selection, Training, Qualification, and Certification
Requirements for DOE Nuclear Facilities.”
12. DOE O 430.1B Chg 2 “Real Property Asset Management.”
13. DOE O 433.1B, “Maintenance Management Program for Nuclear Facilities.”
14. DOE-0336, “Hanford Site Lockout/Tagout.”
15. DOE-0342, “Hanford Site Chronic Beryllium Disease Prevention Program (CBDPP).”
16. DOE-0359, “Hanford Site Electrical Safety Program.”
17. DOE/RL-2012-29, “Hanford Ten Year Site Plan.”
18. HNF-12125, “222-S Laboratory Documented Safety Analysis.”
19. HNF-14755, “242-A Evaporator Documented Safety Analysis.”
20. HNF-5183, “Tank Farms Radiological Control Manual.”
Nuclear Maintenance Management
Program
Manual
Document
Page
Issue Date
Management Plan
TFC-PLN-29, REV C-15
15 of 21
January 30, 2018
21. HNF-MP-5184, “Radiation Protection Program.”
22. RPP-13033, “Tank Farms Documented Safety Analysis.”
23. RPP-7574, “Double Shell Tank Integrity Program Plan.”
24. RPP-PLAN-45082, “Implementation Plan for the Single Shell Tank Integrity Project.”
25. RPP-PLAN-59958, “Process & Control System Engineering Software & Equipment
Obsolescence Plan.”
26. TFC-BSM-CP_CPR-C-05, “Procurement of Services.”
27. TFC-BSM-CP_CPR-C-06, “Procurement of Items (Materials).”
28. TFC-BSM-CP_CPR-C-18, “Material Receipt, Storage, Issuance, Return, and Excess
Control.”
29. TFC-BSM-CP_CPR-C-19, “Controlling Spare Parts Inventory.”
30. TFC-BSM-FPM_PR-C-01, “Property Management.”
31. TFC-BSM-FPM_PR-C-10, “Use and Administration of Mobile Devices.”
32. TFC-BSM-FPM_PR-C-13, “Winterization and Snow Removal Procedure for Tank
Operations Contractor Facilities.”
33. TFC-BSM-TQ-STD-01, “Technical Staff and Technician Qualification Requirements.”
34. TFC-BSM-TQ-STD-03, “Person-In-Charge Qualification Requirements.”
35. TFC-BSM-TQ-STD-10, “Maintenance Craft Qualification Requirements.”
36. TFC-CHARTER-01, “Tank Operations Contractor Charter.”
37. TFC-ENG-DESIGN-C-06, “Engineering Change Control.”
38. TFC-ENG-DESIGN-C-15, “Commercial Grade Dedication.”
39. TFC-ENG-DESIGN-C-18, “Testing Practices.”
40. TFC-ENG-DESIGN-C-34, “Technical Requirements for Procurement.”
41. TFC-ENG-DESIGN-C-35, “Process Hazard Analysis Determination and Technique
Screening.”
42. TFC-ENG-DESIGN-C-47, “Process Hazard Analysis.”
43. TFC-ENG-DESIGN-C-56, “Modification Traveler.”
44. TFC-ENG-FACSUP-C-23, “Equipment Identification and Data Management.”
Nuclear Maintenance Management
Program
Manual
Document
Page
Issue Date
Management Plan
TFC-PLN-29, REV C-15
16 of 21
January 30, 2018
45. TFC-ENG-FACSUP-P-01, “TOC System Engineer Program.”
46. TFC-ENG-SB-C-03, “Unreviewed Safety Question Process.”
47. TFC-ENG-SB-C-06, “Safety Basis Development.”
48. TFC-ENG-STD-02, “Environmental/Seasonal Requirements for TOC Systems,
Structures, and Components.”
49. TFC-ENG-STD-08, “Post Maintenance Testing.”
50. TFC-ESHQ-AP-C-01, “Required and Management-Directed Assessments.”
51. TFC-ESHQ-AP-C-03, “Management Observation Program.”
52. TFC-ESHQ-Q_C-C-01, “Problem Evaluation Request.”
53. TFC-ESHQ-Q_C-C-03, “Control of Suspect/Counterfeit Items.”
54. TFC-ESHQ-RP_ADM-C-11, “Joint Review Group.”
55. TFC-ESHQ-RP_RWP-C-03, “ALARA Work Planning.”
56. TFC-ESHQ-RP_RWP-C-04, “Radiological Work Permits.”
57. TFC-ESHQ-S_SAF-C-02, “Job Hazard Analysis.”
58. TFC-ESHQ-S_SAF-C-12, “Safety Inspections.”
59. TFC-OPS-MAINT-C-01, “Tank Operations Contractor Work Control.”
60. TFC-OPS-MAINT-C-03, “Maintenance Tools and Equipment Control.”
61. TFC-OPS-MAINT-C-06, “Notification and Evaluation of Out-of-Calibration Measuring
and Test Equipment.”
62. TFC-OPS-MAINT-C-07, “Control and Calibration of Measuring and Test Equipment.”
63. TFC-OPS-MAINT-C-12, “Preventive/Predictive Maintenance Administration.”
64. TFC-OPS-OPER-C-01, “Technical Safety Requirement Compliance.”
65. TFC-OPS-OPER-C-11, “Equipment Temporary Modifications and Bypasses.”
66. TFC-OPS-OPER-C-13, “Technical Procedure Control and Use.”
67. TFC-OPS-OPER-C-65, “Rolling Schedule Process.”
68. TFC-PLN-01, “Integrated Safety Management System.”
69. TFC-PLN-02, “Quality Assurance Program Description.”
Nuclear Maintenance Management
Program
Manual
Document
Page
Issue Date
Management Plan
TFC-PLN-29, REV C-15
17 of 21
January 30, 2018
70. TFC-PLN-04, “Property Management Program Plan.”
71. TFC-PLN-05, “Conduct of Operations Implementation Plan.”
72. TFC-PLN-10, “Assessment Program Plan.”
73. TFC-PLN-23, “Configuration Management Plan.”
74. TFC-PLN-26, “Test Program Plan.”
75. TFC-PLN-41, “Integrated Safety Management System Description.”
76. TFC-PLN-47, “Worker Safety and Health Program.”
77. TFC-PLN-61, “Tank Operations Contractor Training and Qualification Plan.”
78. TFC-PLN-83, “Assurance System Program Description.”
79. TFC-PLN-100, “Tank Operations Contractor Requirements Basis Document.”
80. TFC-POL-16, “Integrated Safety Management System Policy.”
81. TFC-POL-24, “Property Management Policy.”
82. TFC-PRJ-PC-C-11, “Performance Indicator Program.”
83. TFC-PRJ-PM-C-02, “Project Management.”
84. TO-040-791, “Obtain/Record Waste Transfer Safety-Significant SSC Temperature Data.”
85. TO-040-792, “R&C Waste Transfer Safety-Significant SSC Temperature Data.”
Nuclear Maintenance Management
Program
Manual
Document
Page
Issue Date
Management Plan
TFC-PLN-29, REV C-15
18 of 21
January 30, 2018
Table 1. TOC Program Plans Applicable to the NMMP.
DOE O 433.1B, Section 2a
Integration with Regulations and
DOE Orders and Manuals (and
their CRDs)
TOC Program Document NMMP section
(1) The following directives
(and their CRDs)
(a) DOE O 226.1B
Implementation of DOE
Oversight Policy
TFC-PLN-01, “Integrated
Environment, Safety, and Health
Management System Plan”
TFC-PLN-41, “Integrated Safety
Management System
Description”
TFC-PLN-10, “Assessment
Program Plan”
TFC-PLN-83, “Assurance
System Program Description”
3.14 Performance Measures;
3.15 Facility Condition
Inspection
3.17 Integration with
Regulations and DOE Orders
and Manuals
(b) DOE 414.1D Quality
Assurance
TFC-PLN-02, “Quality
Assurance Program
Description”
3.10 Suspect and Counterfeit
Items
3.17 Integration with
Regulations and DOE Orders
and Manuals
(c) DOE O 420.1C Facility
Safety
TFC-ENG-FACSUP-P-01,
“TOC System Engineer
Program”
TFC-PLN-23, “Configuration
Management Plan”
3.3 Planning, Scheduling, and
Coordination of Maintenance
3.5 Maintenance Procedures
3.7 Configuration Management
(d) DOE O 430.1B Chg 2 Real
Property Asset Management
TFC-POL-24, “Property
Management Policy”
TFC-PLN-04, “Property
Management Program Plan”
TFC-BSM-FPM_PR-C-01,
“Property Management”
TFC-BSM-FPM_PR-C-10, “Use
and Administration of Mobile
Devices”
TFC-BSM-CP_CPR-C-18,
“Material Receipt, Storage,
Issuance, Return, and Excess
Control”
3.8 Procurement
3.9 Maintenance Tool and
Equipment Control
3.15 Facility Condition
Inspection
(e) DOE O 440.1B Worker
Protection Program for DOE
Federal Employees
TFC-PLN-47, “Worker Safety
and Health Program”
3.5 Maintenance Procedures
3.6 Training and Qualifications
Nuclear Maintenance Management
Program
Manual
Document
Page
Issue Date
Management Plan
TFC-PLN-29, REV C-15
19 of 21
January 30, 2018
Table 1. TOC Program Plans Applicable to the NMMP (cont.)
(f) DOE O 422.1 Conduct of
Operations
TFC-PLN-05, “Conduct of
Operations Implementation
Plan,” Attachment A – Conduct
of Operations Matrix
All
(g) (DOE O 426.2, “Personnel
Selection, Training,
Qualification, and Certification
Requirements for DOE Nuclear
Facilities.
TFC-PLN-61, “Tank Operations
Contractor Training and
Qualification Plan”
3.6 Training and Qualification
of Maintenance Personnel
(h) DOE O 458.1 Radiation
Protection of the Public and
Environment
HNF-5183, “Tank Farm
Radiological Controls Manual”
3.5 Maintenance Procedures
3.6 Training and Qualification
(i) DOE O 450.2 Integrated
Safety Management
TFC-PLN-01
TFC-POL-16, “Operational
Readiness Program Plan”
3.5 Maintenance Procedures;
3.17 Integration with
Regulations and DOE Orders
and Manuals
DOE O 433.1B Section 2
Specific Requirements.
a. Integration with Regulations
and DOE Orders and Manuals
(and their CRDs) (2) Code of
Federal Regulations
TOC Program Document NMMP section
(a) TFC-PLN-02
(b) 10 CFR Part 830, Nuclear
Safety Management, Subpart B
Safety Basis Requirements
TFC-ENG-DESIGN-C-35
TFC-ENG-DESIGN-C-47
TFC-ENG-SB-C-01
TFC-ENG-SB-C-03
TFC-ENG-SB-C-06
TFC-PRJ-PM-C-02
3.5 Maintenance Procedures;
3.17 Integration with
Regulations and DOE Orders
and Manuals
(c) Integrated Safety
Management Systems (ISMS)
provisions in 48 CFR 970.5223-
1 , Integration of Environment,
Safety, and Health into Work
Planning and Execution
TFC-PLN-41, “Integrated Safety
Management System
Description.”
3.5 Maintenance Procedures
(d) 10 CFR 835, Occupational
Radiation Protection
HNF-MP-5184, “Washington
River Protection Solutions, LLC
Radiation Protection Program”
3.5 Maintenance Procedures
(e) 10 CFR Part 850, Chronic
Beryllium Disease Prevention
Program
DOE-0342, “Hanford Site
Chronic Beryllium Disease
Prevention Program (CBDPP)”
3.5 Maintenance Procedures
(f) 10 CFR Part 851, Worker
Safety and Health Program
TFC-PLN-47, “Worker Safety
and Health Program”
3.5 Maintenance Procedures
Nuclear Maintenance Management
Program
Manual
Document
Page
Issue Date
Management Plan
TFC-PLN-29, REV C-15
20 of 21
January 30, 2018
ATTACHMENT A - MAINTENANCE PROGRAM IMPLEMENTING PLANS/PROCEDURES
AND PROCESSES
Program Element
DOE O 433.1B CRD 2
WRPS applicable
Plan/Procedure/Process Applicable sections
(b) Maintenance
Organization and
Administration
TFC-CHARTER-01, “Tank Operations
Contractor Charter”
2.2/Figure 1
TFC-OPS-MAINT-C-01, “Tank
Operations Contractor Work Control”
4.1, 4.2, 4.3, 4.4, 4.6,
4.7, 4.8, 4.11
(c) Master Equipment List TFC-ENG-FACSUP-C-23, “Equipment
Identification and Data Management” all
(d) Planning, Scheduling,
and Coordination of
Maintenance
TFC-OPS-MAINT-C-01, “Tank
Operations Contractor Work Control” all
TFC-OPS-OPER-C-65, “Rolling Schedule
Process” all
(e) Types of Maintenance TFC-ENG-FACSUP-C-23, “Equipment
Identification and Data Management” all
TFC-OPS-MAINT-C-01, “Tank
Operations Contractor Work Control” all
TFC-OPS-MAINT-C-12,
“Preventive/Predictive Maintenance
Administration”
all
(f) Maintenance
Procedures
TFC-OPS-OPER-C-13, “Technical
Procedure Control and Use” all
TFC-OPS-MAINT-C-01, “Tank
Operations Contractor Work Control” all
(g) Training and
Qualification
TFC-BSM-TQ-STD-10, “Maintenance
Craft Qualification Requirements” all
TFC-BSM-TQ-STD-03, “Person-In-
Charge Qualification Requirements” all
TFC-BSM-TQ-STD-01, “Technical,
Professional, and Support Staff
Qualification Requirements”
all
(h) Configuration
Management
TFC-PLN-23, “Configuration Management
Plan” all
(i) Procurement TFC-ENG-DESIGN-C-34, “Technical
Requirements for Procurement” all
TFC-ENG-DESIGN-C-15, “Commercial
Grade Dedication” all
TFC-BSM-CP_CPR-C-05, “Procurement
of Services” all
TFC-BSM-CP_CPR-C-06, “Procurement
of Items (Materials)” all
Nuclear Maintenance Management
Program
Manual
Document
Page
Issue Date
Management Plan
TFC-PLN-29, REV C-15
21 of 21
January 30, 2018
ATTACHMENT A - MAINTENANCE PROGRAM IMPLEMENTING PLANS/PROCEDURES
AND PROCESSES (cont.)
Program Element
DOE O 433.1B CRD 2
WRPS applicable
Plan/Procedure/Process Applicable sections
TFC-BSM-CP_CPR-C-19, “Controlling
Spare Parts Inventory” all
TFC-BSM-CP_CPR-C-18, “Material
Receipt Storage Issuance Return and
Excess Control”
all
(j) Maintenance Tool and
Equipment Control
TFC-OPS-MAINT-C-03, “Maintenance
Tools and Equipment Control”
all
TFC-OPS-MAINT-C-07, “Control and
Calibration of Measuring and Test
Equipment”
all
(k) Suspect and Counterfeit
Items
TFC-ESHQ-Q_C-C-03, “Control of
Suspect/Counterfeit Items” all
(l) Maintenance History TFC-ENG-FACSUP-P-01, “TOC System
Engineer Program” 4.4, 4.6
(m) Aging Degradation and
Technical
Obsolescence
TFC-ENG-FACSUP-P-01, “TOC System
Engineer Program” all
(n) Seasonal Facility
Preservation
TFC-BSM-FPM_PR-C-13, “Winterization
and Snow Removal Procedure for Tank
Operations Contractor Facilities” 3-MISC-
126, “Tank Farms Weekly Check of Heater
and Heat Trace,” 3-MISC-363,
“Winterization/De-Winterization Tank
Farms,”
TO-040-791, “Obtain/Record Waste
Transfer Safety Significant SSC
Temperature Data,”
TO-040-792, “R&C Waste Transfer Safety
Significant SSC Temperature Data”
all
(o) Performance Measures TFC-PRJ-PC-C-11, “Performance
Indicator Program” all
(p) Facility Condition
Inspection
TFC-ENG-FACSUP-P-01, “TOC System
Engineer Program” 4.5
TFC-ESHQ-S_SAF-C-12, “Safety
Inspections” all
TFC-ESHQ-AP-C-03, ”Management
Observation Program” all
TFC-ESHQ-AP-C-01, “Required and
Management-Directed Assessments” all
(q) Post-Maintenance
Testing
TFC-OPS-MAINT-C-01, “Tank
Operations Contractor Work Control” 4.4, 4.7.2
TFC-ENG-STD-08, “Post Maintenance
Testing” all
TFC-PLN-26, “Test Program Plan” all