NUTORK CORPORATIONNUTORK CORPORATIONNUTORK CORPORATIONNUTORK CORPORATIONNUTORK CORPORATION
Electric ActuatorElectric ActuatorNTQ SeriesNTQ SeriesElectric ActuatorElectric ActuatorNTQ SeriesNTQ SeriesElectric ActuatorNTQ Series
Features
NUTORK www.nutork.com — NTQ Electric ActuatorTM1
1. Housing:hard-anodized AL alloy and external coating of epoxy powder is suitable for the severe condition especially
against the corrosion.Housing is designed in accordance with standard of Explosion-proof and IP67.and also we can
offer NUTORKTM NTQ with IP68 for option.
2. Motor: specially designed with squirrel caged induction motor to generate high starting torque and high efficiency
equipped with thermal protector to prevent damage from over heating.it has several features such as high output
power,high efficiency and lower noise.
3. PCU: high performance microprocessor, auto-calibration provides the most convenient to user without complicated set
in field.
4. Sealing: sealing provided by double O-ring system.
5. Handwheel: Just by pulling over the lever, operating mode is switched to manual. then just supplying electrical power
to actuator, clutch is automatically disengaged from manual and operating mode is switched to electric operation. The
size of hand wheel is designed according to required torque to move the actuator, so that operator can easily move
6. Gear & self locking: 2nd staged double worm gearing prevents movment caused by backward force transferred from
valve and it provides the exact and stable position of actuator and valve when the power is off. High efficiency, high
output torque, low noise level are another advantages.
Features
NUTORK www.nutork.com — NTQ Electric ActuatorTM 2
7. Limit switches: directly engaged with driving shaft to set accurate position of valve. Torque swithces: to protect actuator
from damage caused by over torque from the driven valve over the whole travel.
8. Anti-condensation space heater: the switch is open when the temperature is around 20±3℃ to protedct actuator
condensation; The switch is close when the temperature is over 30±3℃ to prevent over heating.
9. Stopper bolt: stopper bolt installed both close and open direction prevents actuator’s travel the limit during
manual operation and also protects internal gearing from its breakaway.
10. Indicator: through the large size indicator window provides bettr position indication form a distance.
11. Terminal block: it is easy to add the number of strip for additional connection, spring loaded terminal strip is very
strong against vibration.
12. Wiring: the inside wiring is so simple and easy to connect.
13. Driving bushing: the driving bushing is removable to process, mounting base is designed according to ISO5211, it is
convenient to adapt with valve.
14. Lubrication: all the gears and shafts use CIATM221 type Grease Moly, it is not necessary to refill lubricant for 5
years.
15. Anti-interference magnetic loop: it effectively prevents the actuator from outside magnetic field, and keeps the
actuator operating stable.
Features
NUTORK www.nutork.com — NTQ Electric ActuatorTM3
NUTORKTM NTQ electric actuator guaranty high performance and stable quality product throughout severe test and inspection. We can provide advanced intelligent
model with different models for option.
1. Using very large scale digital integrated chip, so it has very powerful function and high accuracy. Once the actuator is
supplied power, it will auto-check the control circuit to insure the correct operation.
2. Displacement transducer of actuator is n. hall sensor with digital quantization impulse signal, Hall magnetically pulse
effects system can measure and control the travel of actuator exactly.
3. Using IA infrared ray system, IA always supports communication compatible with IrDA. The function specification of
actuator can be set, adjusted and operated by handheld infrared remote controller, it is not necessary to open the top
cover to reveal the inner control circuit.
4. Using liquid crystal display with high-resolution, English mark to indicate the travel percent of valve, It is very convenient
to use in the night. LED signal with high lightness to indicate the position of actuator: full open-Red, full close-Green.
The backup batteries will support the LED display when the main power is off.
5. The remote and local control (open/close/stop) function, with local lamp indication: full colse-Green (on). Closing-Green
(flickering). Torque switch trip-Yellow (on), Fault-Yellow (Flickering). Full open-Red(on), Opening-Red(Flickering).
Reversing, electronic contactors, Transformer, Phase discriminator has detection and auto-correction. 24 to 48 points
terminal strips on terminal block for option. Position monitoring relays with remote position indication, local digital position
indication.
Standard Specification
NUTORK www.nutork.com — NTQ Electric ActuatorTM 4
NEMA
(SPDT 250VAC/10A rating except for NTQ100)
Set
De-clutchable
Space heater
powder
Option Availability
NUTORK www.nutork.com — NTQ Electric ActuatorTM5
central
Technical Information
NUTORK www.nutork.com — NTQ Electric ActuatorTM 6
Type NTQ500
500
30
31
26
40
34
3.60
3.90
1.50
1.60
0.52
0.56
0.55
0.58
F
90W
F12/F14
20
14
NTQ800
800
30
39
32
48
40
3.90
4.20
2.05
2.20
0.82
0.88
0.82
0.88
F
180W
F12/F14
25
17
NTQ1100
1100
30
39
32
48
40
3.90
4.30
2.15
2.30
0.84
0.90
0.84
0.88
F
180W
F12/F14
25
17
NTQ1500
1500
30
93
78
75
64
3.60
3.90
1.50
1.60
0.52
0.56
0.55
0.58
F
90W
F16
65
65
NTQ2000
2000
30
117
97
75
64
3.80
4.20
2.05
2.20
0.82
0.88
0.82
0.88
F
180W
F16
75
70
NTQ3000
3000
30
117
97
75
64
3.80
4.20
2.15
2.30
0.84
0.90
0.84
0.88
F
180W
F16
75
70
NTQ350
350
30
31
26
40
34
1.72
1.80
0.92
0.95
0.32
0.32
0.32
0.35
F
40W
F10/F12
15
14
NTQ240
240
30
26
22
25
23
1.62
1.72
0.87
0.90
0.32
0.32
0.32
0.35
F
40W
F10/F12
15
12
1.60
1.70
0.85
0.90
0.30
0.30
0.30
0.32
F
40W
F07/F10
15
12
NTQ160
160
30
26
22
25
23
F07
7
10
NTQ100
100
40
21
18
22
22
Torque(Nm)
Duty cycle(%)
50Hz
60Hz
Key type
Squaretype
50Hz
60Hz
50Hz
60Hz
50Hz
60Hz
50Hz
60Hz
Operating
time(sec)
Max bore
size(mm)
Rated current(A)
1Phase/110V
1Phase/220V
3Phase/380V
3Phase/440V
Motor insulation class
Motor power
ISO 5211 mountingflange
Weight(kgs)
No. of handwheelturns
0.98
1.10
0.52
0.58
0.43
0.33
0.59
F
15W
0.42
Construction
NUTORK www.nutork.com — NTQ Electric ActuatorTM7
Parts List
NUTORK www.nutork.com — NTQ Electric ActuatorTM 8
Part Name Part Name Part Name
Dimension
NUTORK www.nutork.com — NTQ Electric ActuatorTM9
Dimension
NUTORK www.nutork.com — NTQ Electric ActuatorTM 10
With Gear BoxNTQ NTQ NTQ NTQ NTQ NTQ NTQ NTQ NTQ NTQ
Wiring Diagram
Wiring Diagram(NTQ100)
Wiring Diagram(NTQ160——NTQ3000)
NUTORK www.nutork.com — NTQ Electric ActuatorTM11
Wiring Diagram
NUTORK www.nutork.com — NTQ Electric ActuatorTM 12
Wiring Diagram(NTQ160——NTQ3000)
Wiring Diagram(NTQ160——NTQ3000)
Wiring Diagram
Wiring Diagram(NTQ100——NTQ300)
NUTORK www.nutork.com — NTQ Electric ActuatorTM13
Dimension
NUTORK www.nutork.com — NTQ Electric ActuatorTM 14
Wiring Diagram
(LD2 for 3phase) Wiring Diagram
NUTORK www.nutork.com — NTQ Electric ActuatorTM15
Dimension
NUTORK www.nutork.com — NTQ Electric ActuatorTM 16
Mounting Dimension
NTQ-100 NTQ-160,240
NTQ-1500,2000,3000
NTQ-350,500 NTQ-800,1100
NTQ-100 NTQ-160,240 NTQ-350,500 NTQ-800,1100 NTQ-1500,2000,3000
Wiring Diagram
PCU Wiring Diagram
NUTORK www.nutork.com — NTQ Electric ActuatorTM17
Order Information
NTQ-
NTQ
NUTORK Corp.NUTORK AMERICAS4951 N. Peachtree Road ATLANTA, GA 30338-5322, USATel: + 1 (770) 451-4141 Fax: +1 (770) 234-6664E-mail:[email protected]
China Office:621 Jiang-Chuan Road, Min-Hang Area, Shanghai,ChinaTel :+86-21-6430-7578Fax:+86-21-6430-5608E-mail:[email protected]
South-East Asia Office:51 Jalan Pemimpin,#03-06 Mayfair Industrial Building,Singapore 577206Tel:+65-6258-1701Fax:+65-6258-6126E-mail:[email protected]
Mode Torque Powe Control Type Protection Option
100 1)24VDC 1)on/off 1)Weather-Proof IP67 1)Lever & Yoke
160 2)110VAC 2)modulating 2)Local Control Unit
240 3)220VAC
2)Explosion-Proof EExdIIBT4
350 4)380VAC
500 5)440VAC
800
1100
1500
2000
3000