nuvo COOLING UNIT UPGRADE
b y ko olspaceTM
INSTALLATION & OPERATION
BEFORE YOU START
SCREW INSERTS x 2
ALLEN KEY x 1
HARDWARE
MAKE SURE TO WRITE DOWN YOUR SERIAL
NUMBER AND SAVE IT !!!
32 mm1.25"
423 mm16.625"
Ø 9 x 25.4OR 11/32" x 1" DEEP
NEW SETUP
PREPARE FOR INSTALLATION
CUT OUT PATTERN ON BACK PAGE AND ALIGN WITH EDGE OF COOL-ING UNIT HOLE TO MARK FOR DRILL-ING
1
1
1
USE 9mm OR 11/32” DRILL BIT, DRILL HOLE 1” DEEP
2
2
INSERT SCREW INSERT3
3
4b
4b
BACKOFCELLAR
BACK OF CELLAR
BACK
MAKE SURE DISTANCE BETWEEN THE HOLES IS CORRECT BEFORE
DRILLING!!!
CELLARS WITHOUT INSULATION STRIPSUSE 3/4” FOAM TAPE 1/8” THICK ON ALL 4 SIDES OF INSIDE FLANGE
4a
YOUR ORIGINAL SETUP
4b
BACK
FOR TUSCANY PLUS CELLARSREMOVE ALL 4 INSULATION STRIPS AND FLIP TO RE-INSERT AS NEW SET UP
2 Flange bolts in cooling unit box.
COOLING UNIT INSTALLATION
1
A
B
TOP VIEW
Run light cord through Cut-out. Slide unit into the back opening by angling unit A to allow light cord to clear and straighten to push in B . Screw allen bolts through bottom flange holes. Make sure unit is level!
NOTE: If unit is operated according to specifications overflows will not occur. Excess condensation is only caused by extreme conditions. Unit will shut off at 72 °F and will restart when temperature drops or unit is plugged in. (In this case insert 3/8” O.D. hose to drain hole, cut to appropriate length.)
Container
Optional (not required) except as emergency drain.
BACKOFCELLAR
TOP VIEW
FEATURES: - Default SET temperature 57º F/14º C (ideal for wine storage). - Calibration option of the temperature sensor. - Display of actual temperature by request. - SET temperature range 52ºF-64ºF. - Digital temperature sensor. - Dual display Fº/Cº. - Settings are stored in memory for power failures. - Pre programed software will reach the quietest most efficient operation.
OPERATION: - The display will show the detected temperature until the temperature will fall within 3º of the SET POINT. - If the temperature is above the default 57º F + 1º or other preset value, after a delay of 1 minute the fan will start, followed by the compressor within the next minute. - The unit will cycle ON/OFF based on the temperature reading. Fan speeds are automatically set by the controller to achieve optimum performance. - Minimum ON and OFF cycle times are imposed by software, to prevent "short cycling".
SAFETY FEATURES:
ALARM: - If the temperature exceeds 72º F the unit will shut down, a sound warning will start and the dispaly will blink alternating with the temperature reading. - This function is disabled in the first 4 hours “ Cool Down” period or after any reset for another 4 hours. - The unit will restart and continue the cooling and cycling if the temperature falls below 72º F.
TO RESET: - Unplug and re plug the unit.
57º 56º
70º 57º
57º 57º
57º 58º
57º 56º
57º 14º
57º 57º
57º F0
F0 F1
F0 -1
Actual temperature: PRESS
SET temperature: PRESS
PRESS and RELEASE
To increase: PRESS once per degree
To decrease: PRESS once per degree
The new value will be memorized and the controller will reset automatically.
PRESS and HOLD until buzzer sounds in 5 seconds
The new value will be memorized and the controller will reset automatically.
PRESS and HOLD while holding PRESS and RELEASEWait 5 secondsUSE or for each degree of offset
DISPLAY EXAMPLE
BEFORE AFTER
TO DISPLAY:
TO MODIFY SET TEMPERATURE(range is 52-64ºF):
TO CHANGE FROM ºF to ºC: or ºC to ºF TO CALIBRATE:
CONTROLLER OPERATION ACTION
NOTE: A negative offset will result in a warmer cabinet and a positive offset will result in a cooler cabinet. The new value will be memorized and the controller will reset automatically.
CONTROLS : PLUG IT IN (wait one minute) and ENJOY!
57
KEYS
AL
DISPLAY:
PLEASE CUT OUT TEMPLATE PATTERN FOR DRILL HOLE PLACEMENT