8
LANDSCAPE LAYOUT - GROUND LEVEL OAK STREET LANDSCAPE SET: ISSUED FOR REZONING APRIL 27, 2017 LANDSCAPE DRAWING INDEX SHEET No. SHEET NAME L 0.0 COVER SHEET AND DRAWING LIST PLANT MATERIALS GENERAL NOTES LANDSCAPE LAYOUT - ROOF LANDSCAPE ENLARGEMENTS - GROUND LEVEL L 1.1 L 1.2 L2.0 ALL LANDSCAPE ARCHITECTURAL DRAWINGS IN THIS PACKAGE SHALL BE READ IN CONJUNCTION WITH ALL OTHER LANDSCAPE ARCHITECTURAL DRAWINGS, DETAILS, SPECIFICATIONS, AND OTHER CORRESPONDANCE THAT MAY BE ISSUED DURING THE COURSE OF THE CONTRACT. IF A DISCREPANCY OCCURS BETWEEN THE DRAWINGS AND THE SPECIFICATIONS OR ANY OTHER DOCUMENT ASSOCIATED WITH THE PROJECT, THE CONFLICT SHALL BE REPORTED IN WRITING TO THE LANDSCAPE ARCHITECT TO OBTAIN CLARIFICATION AND APPROVAL BEFORE PROCEEDING WITH WORKS. ALL EXISTING INFORMATION IS BASED ON AVAILABLE RECORDS AND SHALL NOT BE CONSTRUED TO BE COMPLETE OR ACCURATE. ALL PLANTING SHALL BE IN ACCORDANCE WITH BC LANDSCAPE STANDARD, LATEST EDITION. CONNECT LANDSCAPE ARCHITECTURE INC. DOES NOT GUARANTEE THE EXISTENCE, LOCATION, AND ELEVATION OF UTILITIES OR CONCEALED STRUCTURES AT THE PROJECT SITE. FINAL SELECTION AND APPROVAL OF ALL STREET TREES TO BE DONE BY THE CITY OF VANCOUVER. L3.0 L3.1 DETAILS - SOFTSCAPE L 1.0 DETAILS - HARDSCAPE DETAILS - FURNISHINGS L3.2 REVISIONS Project No. Reviewed: Drawn: Scale: 06-537 Vancouver, British Columbia OAK STREET Connect Landscape Architecture Inc. ISSUED FOR REZONING 17-04-27 1 L0.0 1:200 KD DS COVER SHEET AND DRAWING LIST CONNECT LANDSCAPE ARCHITECTURE INC. DOES NOT GUARANTEE THE EXISTENCE, LOCATION, AND ELEVATION OF UTILITIES AND / OR CONCEALED STRUCTURES AT THE PROJECT SITE. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE EXISTENCE, LOCATION, AND ELEVATION OF ALL UTILITIES AND / OR CONCEALED STRUCTURES, AND IS RESPONSIBLE FOR NOTIFYING THE APPROPRIATE COMPANY, DEPARTMENT OR PERSON(S) OF ITS INTENTION TO CARRY OUT ITS OPERATIONS. 2305 Hemlock St, Vancouver BC, V6H 2V1 T 604 681 3303 F 604 681 3307 www.connectla.ca 98.83' (30.12m) 98.83' (30.12m) 98.83' (30.12m) Up Up 12.5% Dn 98.83' (30.12m) Up 98.83' (30.12m) 98.83' (30.12m) 98.83' (30.12m) Dn Up 98.83' (30.12m) LANE 93.88' DN 93.71' DN UP UP DN TOS 99' (30.18m) TOW99.13' (30.21m) BOW96.87' (29.53m) COOLING TOWER M.U.A Canopy above 159'10" (48.72m) L A N E O A K S T R E E T 0 5 10 m

OAK STREET - Vancouver · coniferous tree planting on slab (typical) 4 scale: 1:25 tree rootball 50mm x 200mm timber or x-potential deadman stainless steel wire and turnbuckle galvanized

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: OAK STREET - Vancouver · coniferous tree planting on slab (typical) 4 scale: 1:25 tree rootball 50mm x 200mm timber or x-potential deadman stainless steel wire and turnbuckle galvanized

LANDSCAPE LAYOUT - GROUND LEVEL

OAK STREETLANDSCAPE SET: ISSUED FOR REZONING

APRIL 27, 2017

LANDSCAPE DRAWING INDEXSHEET No. SHEET NAME

L 0.0 COVER SHEET AND DRAWING LIST

PLANT MATERIALS

GENERAL NOTES

LANDSCAPE LAYOUT - ROOF

LANDSCAPE ENLARGEMENTS - GROUND LEVELL 1.1

L 1.2

L2.0

ALL LANDSCAPE ARCHITECTURAL DRAWINGS IN THIS PACKAGE SHALL BE READ IN CONJUNCTION WITH ALL OTHER LANDSCAPE ARCHITECTURAL DRAWINGS, DETAILS, SPECIFICATIONS, AND OTHER CORRESPONDANCE THAT MAY BE ISSUED DURING THE COURSE OF THE CONTRACT.

IF A DISCREPANCY OCCURS BETWEEN THE DRAWINGS AND THE SPECIFICATIONS OR ANY OTHER DOCUMENT ASSOCIATED WITH THE PROJECT, THE CONFLICT SHALL BE REPORTED IN WRITING TO THE LANDSCAPE ARCHITECT TO OBTAIN CLARIFICATION AND APPROVAL BEFORE PROCEEDING WITH WORKS.

ALL EXISTING INFORMATION IS BASED ON AVAILABLE RECORDS AND SHALL NOT BE CONSTRUED TO BE COMPLETE OR ACCURATE.

ALL PLANTING SHALL BE IN ACCORDANCE WITH BC LANDSCAPE STANDARD, LATEST EDITION. CONNECT LANDSCAPE ARCHITECTURE INC. DOES NOT GUARANTEE THE EXISTENCE, LOCATION, AND ELEVATION OF UTILITIES OR CONCEALED STRUCTURES AT THE PROJECT SITE.

FINAL SELECTION AND APPROVAL OF ALL STREET TREES TO BE DONE BY THE CITY OF VANCOUVER.

L3.0

L3.1

DETAILS - SOFTSCAPE

L 1.0

DETAILS - HARDSCAPE

DETAILS - FURNISHINGSL3.2

REVISIONS

Project No.

Reviewed:

Drawn:

Scale:

06-537

Vancouver, British Columbia

OAK STREET

Conn

ect L

ands

cape

Arc

hite

ctur

e In

c.

ISSUED FOR REZONING 17-04-271

L0.0

1:200

KD

DS

COVER SHEET ANDDRAWING LIST

CONNECT LANDSCAPE ARCHITECTURE INC.

DOES NOT GUARANTEE THE EXISTENCE,

LOCATION, AND ELEVATION OF UTILITIES AND /

OR CONCEALED STRUCTURES AT THE PROJECT

SITE.

THE CONTRACTOR IS RESPONSIBLE FOR

DETERMINING THE EXISTENCE, LOCATION, AND

ELEVATION OF ALL UTILITIES AND / OR

CONCEALED STRUCTURES, AND IS

RESPONSIBLE FOR NOTIFYING THE

APPROPRIATE COMPANY, DEPARTMENT OR

PERSON(S) OF ITS INTENTION TO CARRY OUT ITS

OPERATIONS.

2305 Hemlock St, Vancouver BC, V6H 2V1T 604 681 3303 F 604 681 3307www.connectla.ca

98.83' (30.12m)

98.83' (30.12m)98.83' (30.12m)Up

Up

12.5

%

Dn

98.83' (30.12m)

Up

98.83' (30.12m)98.83' (30.12m)

98.83' (30.12m)

Dn Up

98.83' (30.12m)

LANE

93.88'

DN

93.71'

DN

UP

UP

DN

TOS

99' (30.18m)

TOW 99.13' (30.21m)

BOW 96.87' (29.53m)

COOLING TOWER

M.U.A

Canopy above

159'10" (48.72m)

L A N E

O A K S T R E E T

0 5 10 m

Page 2: OAK STREET - Vancouver · coniferous tree planting on slab (typical) 4 scale: 1:25 tree rootball 50mm x 200mm timber or x-potential deadman stainless steel wire and turnbuckle galvanized

98.83' (30.12m)

98.83' (30.12m) 98.83' (30.12m)Up

Up

12.5

%

Dn

98.83' (30.12m)

Up

98.83' (30.12m)98.83' (30.12m)

98.83' (30.12m)

Dn Up

98.83' (30.12m)

LANE93.88'

DN93.71'

DN

UP

UP

DN

TOS

99' (30.18m)

TOW 99.13' (30.21m)

BOW 96.87' (29.53m)

SIT

ELI

NE

SRW - SIDEWALK

12' R.O.W

16' R

.O.W

8' S

IDE

WA

LK6'

BO

ULE

VA

RD

L A N E

O A K S T R E E T

0 5 10 m

SLAB EXTENT SLAB EXTENT

SLAB

EXT

ENT

SLAB EXTENT SLAB EXTENT

SLAB

EXT

ENT

SLAB

EXT

ENT

REVISIONS

Project No.

Reviewed:

Drawn:

Scale:

06-537

Vancouver, British Columbia

OAK STREET

Conn

ect L

ands

cape

Arc

hite

ctur

e In

c.

ISSUED FOR REZONING 17-04-271

L1.0

1:100

KD

DS

LANDSCAPE PLANGROUND LEVEL

CONNECT LANDSCAPE ARCHITECTURE INC.

DOES NOT GUARANTEE THE EXISTENCE,

LOCATION, AND ELEVATION OF UTILITIES AND /

OR CONCEALED STRUCTURES AT THE PROJECT

SITE.

THE CONTRACTOR IS RESPONSIBLE FOR

DETERMINING THE EXISTENCE, LOCATION, AND

ELEVATION OF ALL UTILITIES AND / OR

CONCEALED STRUCTURES, AND IS

RESPONSIBLE FOR NOTIFYING THE

APPROPRIATE COMPANY, DEPARTMENT OR

PERSON(S) OF ITS INTENTION TO CARRY OUT ITS

OPERATIONS.

2305 Hemlock St, Vancouver BC, V6H 2V1T 604 681 3303 F 604 681 3307www.connectla.ca

CIP CONCRETE PATHBROOM FINISH CONCRETE

PATIO PAVERS9" X 9" CONCRETE PAVERS

ROOF PATIO SLAB PAVERS2' X 2' ARCHITECTURAL SLABS

PEDESTRIAN PAVERSBARKMAN BOARDWALK PAVER

GRAVEL EDGEPER PLANS AND DETAILS

SOD LAWNPER PLANS AND DETAILS

PLANTED AREAPER PLANS AND DETAILS

RAISED PLANTERPER PLANS AND DETAILS

FURNISHINGSBIKE RACK & BENCH

DECIDUOUS TREEPER PLANS AND DETAILS

EVERGREEN TREEPER PLANS AND DETAILS

STEPPING STONESPER PLANS AND DETAILS

MATERIALS LEGEND

Page 3: OAK STREET - Vancouver · coniferous tree planting on slab (typical) 4 scale: 1:25 tree rootball 50mm x 200mm timber or x-potential deadman stainless steel wire and turnbuckle galvanized

REVISIONS

Project No.

Reviewed:

Drawn:

Scale:

06-537

Vancouver, British Columbia

OAK STREET

Conn

ect L

ands

cape

Arc

hite

ctur

e In

c.

ISSUED FOR REZONING 17-04-271

L1.1

N/A

KD

DS

LANDSCAPE ENLARGEMENTSGROUND LEVEL

CONNECT LANDSCAPE ARCHITECTURE INC.

DOES NOT GUARANTEE THE EXISTENCE,

LOCATION, AND ELEVATION OF UTILITIES AND /

OR CONCEALED STRUCTURES AT THE PROJECT

SITE.

THE CONTRACTOR IS RESPONSIBLE FOR

DETERMINING THE EXISTENCE, LOCATION, AND

ELEVATION OF ALL UTILITIES AND / OR

CONCEALED STRUCTURES, AND IS

RESPONSIBLE FOR NOTIFYING THE

APPROPRIATE COMPANY, DEPARTMENT OR

PERSON(S) OF ITS INTENTION TO CARRY OUT ITS

OPERATIONS.

2305 Hemlock St, Vancouver BC, V6H 2V1T 604 681 3303 F 604 681 3307www.connectla.ca

Up

98.83' (30.12m)

98.83' (30.12m)

98.83' (30.12m)

SRW - SIDEWALK

8' S

IDE

WA

LK6'

BO

ULE

VA

RD

0 5 m

AMENITY PLAY AREA ENLARGEMENT1:401

FRONT ENTRANCE ENLARGEMENT1:402

PLAY STEP “LOGS”

TRELLIS

PATIO FURNITURETABLE AND CHAIRS

CONCRETE SLAB PAVING

HEDGE SCREENING

RAISED PLANTERS

BIKE RACKS

FEATURE UNIT PAVING

BENCHES

CITY BOULEVARD

CIP SIDEWALK

Page 4: OAK STREET - Vancouver · coniferous tree planting on slab (typical) 4 scale: 1:25 tree rootball 50mm x 200mm timber or x-potential deadman stainless steel wire and turnbuckle galvanized

COOLING TOWER

M.U.A

Canopy above

159'10" (48.72m)

L A N E

O A K S T R E E T

0 5 10 m

ROOF DECK BELOWROOF DECK BELOW

ROOF DECK BELOW ROOF DECK BELOW

CANOPY CANOPYCANOPY

CANOPY CANOPYCANOPY

REVISIONS

Project No.

Reviewed:

Drawn:

Scale:

06-537

Vancouver, British Columbia

OAK STREET

Conn

ect L

ands

cape

Arc

hite

ctur

e In

c.

ISSUED FOR REZONING 17-04-271

L1.2

1:100

KD

DS

LANDSCAPE PLANROOF LEVEL

CONNECT LANDSCAPE ARCHITECTURE INC.

DOES NOT GUARANTEE THE EXISTENCE,

LOCATION, AND ELEVATION OF UTILITIES AND /

OR CONCEALED STRUCTURES AT THE PROJECT

SITE.

THE CONTRACTOR IS RESPONSIBLE FOR

DETERMINING THE EXISTENCE, LOCATION, AND

ELEVATION OF ALL UTILITIES AND / OR

CONCEALED STRUCTURES, AND IS

RESPONSIBLE FOR NOTIFYING THE

APPROPRIATE COMPANY, DEPARTMENT OR

PERSON(S) OF ITS INTENTION TO CARRY OUT ITS

OPERATIONS.

2305 Hemlock St, Vancouver BC, V6H 2V1T 604 681 3303 F 604 681 3307www.connectla.ca

CIP CONCRETE PATHBROOM FINISH CONCRETE

PATIO PAVERS9" X 9" CONCRETE PAVERS

ROOF PATIO SLAB PAVERS2' X 2' ARCHITECTURAL SLABS

PEDESTRIAN PAVERSBARKMAN BOARDWALK PAVER

GRAVEL EDGEPER PLANS AND DETAILS

SOD LAWNPER PLANS AND DETAILS

PLANTED AREAPER PLANS AND DETAILS

RAISED PLANTERPER PLANS AND DETAILS

FURNISHINGSBIKE RACK & BENCH

DECIDUOUS TREEPER PLANS AND DETAILS

EVERGREEN TREEPER PLANS AND DETAILS

STEPPING STONESPER PLANS AND DETAILS

MATERIALS LEGEND

Page 5: OAK STREET - Vancouver · coniferous tree planting on slab (typical) 4 scale: 1:25 tree rootball 50mm x 200mm timber or x-potential deadman stainless steel wire and turnbuckle galvanized

Prunus laurocerasus 'Zabeliana'Zabel Laurel

Crocosmia 'Lucifer''Red Flowering Crocosmia

Oxalis oreganaRedwood Spurge

Rubus calycinoidesEmerald Carpet

PATIO PLANTERS

Polystichum munitumWestern Sword Fern

Hemerocalis fulvaDay Lily

Rhododendron 'Scarlet Wonder'Scarlet Rhododendron

Taxus x media 'Hicksii"Hick's Yew

LAYERED STREETSCAPE

REVISIONS

Project No.

Reviewed:

Drawn:

Scale:

06-537

Vancouver, British Columbia

OAK STREET

Conn

ect L

ands

cape

Arc

hite

ctur

e In

c.

ISSUED FOR REZONING 17-04-271

L2.0

N/A

KD

DS

LANDSCAPEPLANT MATERIALS

CONNECT LANDSCAPE ARCHITECTURE INC.

DOES NOT GUARANTEE THE EXISTENCE,

LOCATION, AND ELEVATION OF UTILITIES AND /

OR CONCEALED STRUCTURES AT THE PROJECT

SITE.

THE CONTRACTOR IS RESPONSIBLE FOR

DETERMINING THE EXISTENCE, LOCATION, AND

ELEVATION OF ALL UTILITIES AND / OR

CONCEALED STRUCTURES, AND IS

RESPONSIBLE FOR NOTIFYING THE

APPROPRIATE COMPANY, DEPARTMENT OR

PERSON(S) OF ITS INTENTION TO CARRY OUT ITS

OPERATIONS.

2305 Hemlock St, Vancouver BC, V6H 2V1T 604 681 3303 F 604 681 3307www.connectla.ca

PLANT LISTQTY. BOTANICAL NAME COMMON NAME SIZE SPACINGTREES

10 Acer palmatum 'Osakazuki' Japanese Maple 5cm cal., B&B as shown

6 Fagus sylvatica 'Dawyck' Purple Beech 5cm cal., B&B as shown

10 Liquidambar styracifula Sweet Gum 5cm cal., B&B as shown

4 Stewartia pseudocamellia Japanese Stewartia 5cm cal., B&B as shown

2 Styrax japonicus Snowbell Tree 5cm cal., B&B as shown

5 Street Tree - Species TBD by City of Vancouver

SHRUBS

full/part 0 Cornus sericea 'Kelseyi' Dwarf Kelsyi Dogwood #3 pot 24" o.c

full/part 0 Cotoneaster dammeri Little-Leaf Cotoneaster #2 pot 24" o.c

full/part 0 Pieris japonica 'Forest Flame' Lily-of-the-Valley Shrub #5 pot 36" o.c

shade 0 Polystichum munitum Western Sword Fern #2 pot 24" o.c

shade 0 Prunus laurocerasus 'Zabeliana' Zabel Laurel #2 pot 24" o.c

shade 0 Rhododendron 'Scarlet Wonder' Scarlet Rhododendron #2 pot 24" o.c

sun 0 Spiraea x bumulda 'Goldflame' Goldflame Spiraea #3 pot 24" o.c

shade 0 Skimmia japonica Japanese skimmia #3 pot 24" o.c

full/part 252 Taxus x media 'Hicksii' Hick's Yew - 1.2m high #5 pot 24" o.c

GROUND COVERS AND VINES

shade 2 Oxalis oregana Redwood Spurge 4"(10cm) pot 15" o.c

shade 2 Pachysandra terminalis (50/50 mix) Japanese spurge 4"(10cm) pot 15" o.cOxalis oregana Redwood Spurge

sun 0 Parthenocissus quinquefolia Virginia Creeper 4"(10cm) pot 12" o.c

sun 2 Rubus calycinoides Emerald Carpet 4"(10cm) pot 15" o.c

PERENNIALS, BULBS, AND ANNUALS

0 Hemerocallis fulva Day LIly 4"(10cm) pot 18" o.c

NOTES:1) In case of discrepancy between plant numbers on this list and on the plan, the latter shall prevail.2) All planting shall be in accordance with BC Landscape Standard, latest edition. 3) All planting beds to be mulched with 2" (50mm) of Answer Garden Products 'Humus builder' or approved equal.

Page 6: OAK STREET - Vancouver · coniferous tree planting on slab (typical) 4 scale: 1:25 tree rootball 50mm x 200mm timber or x-potential deadman stainless steel wire and turnbuckle galvanized

POSITIVE DRAINAGE

SOD LAWN (TYPICAL)Scale: 1:106

FILTER FABRIC

ROOF ASSEMBLY, SEE ARCHITECTURAL

STRUCTURAL SLAB, SEE ARCHITECTURAL

50mm WASHED SAND (FILTER LAYER)

SAND BASED GROWING MEDIUM TO 250mm DEPTH, AS SPECIFIED

250

50

SOD AS PER SPECIFICATIONS

EXISTING SUBGRADE

150mm MIN. SCARIFIEDEXISTING SUBGRADE

SAND BASED GROWINGMEDIUM TO 100mm

DEPTH, AS SPECIFIED

SOD AS PER SPECIFICATIONS

ON GRADE ON SLAB

MIN

. 600

DECIDUOUS TREE PLANTING ON GRADE (TYPICAL)Scale: 1:201

MIN. 2x ROOT BALL

SPECIES PER PLANTING PLAN

INSTALL TREE STAKE, AS SPECIFIED

1250mm DIA SAUCER AT EDGE OF TREE PIT

INSTALL 50mm MULCH

ADJACENT CONDITIONS VARY PER PLANS

150mm MIN. SCARIFIED EXISTING SUBGRADE

EXISTING SUBGRADE

TAMPED GROWING MEDIUM

INSTALL TOP OF ROOTZONE 150mm ABOVE FINISHED GRADE OF SPECIFIED GROWING MEDIUM.

MIN. 2x ROOT BALL

CONIFEROUS TREE PLANTING ON GRADE (TYPICAL)Scale: 1:202

SPECIES PER PLANTING PLAN

INSTALL 50mm MULCH

MIN

. 600

ADJACENT CONDITIONS VARY PER PLANS

150mm MIN. SCARIFIED EXISTING SUBGRADE

EXISTING SUBGRADE

TAMPED GROWING MEDIUM

INSTALL TOP OF ROOTZONE 150mm ABOVE FINISHED GRADE OF SPECIFIED GROWING MEDIUM.

1250mm DIA SAUCER AT EDGE OF TREE PIT

INSTALL TREE STAKE, AS SPECIFIED

TREE ROOTBALL

SHRUB AND GROUNDCOVER PLANTING (TYPICAL)Scale: 1:255

DISTANCE FROM EDGE IS HALF THE SPECIFIED O.C. SPACING ROW

PLANT CENTRE

TRIANGULAR SPACING AT SPECIFIED O.C. DISTANCE -SEE PLANT SCHEDULE

OPTIONAL : BULB PLANTING AT CENTRE OF ANNUAL "TRIANGLE" EQUIDISTANT FROM EACH PLANT O.C.

STRUCTURAL SLAB, SEE ARCHITECTURAL

FILTER FABRIC

ROOF ASSEMBLY, SEE ARCHITECTURAL

50mm WASHED SAND (FILTER LAYER)

INSTALL MULCH TO 50mm DEPTH

INSTALL SPECIFIED GROWING MEDIUM TO MINIMUM 450mm DEPTH

SPECIES PER PLANTING PLAN

OPTIONAL BULB PLANTINGAT CENTRE OF ANNUAL

"TRIANGLE" EQUIDISTANTFROM EACH PLANT O.C.

150mm MIN. SCARIFIED EXISTING SUBGRADE

EXISTING SUBGRADE

INSTALL SPECIFIEDGROWING MEDIUM TO

MINIMUM 450mm DEPTH

ON GRADE ON SLAB

DECIDUOUS TREE PLANTING ON SLAB (TYPICAL)Scale: 1:253

MIN. 2x ROOT BALL

STRUCTURAL SLAB, SEE ARCHITECTURAL

FILTER FABRIC

ROOF ASSEMBLY, SEE ARCHITECTURAL

TREE ROOTBALL

50mm x 200mm TIMBER OR X-POTENTIAL DEADMAN

STAINLESS STEEL WIRE AND TURNBUCKLE

GALVANIZED STEEL STRAP BOLTED TO WOOD

ADJACENT CONDITIONS VARY PER PLANS

50mm WASHED SAND (FILTER LAYER)

INSTALL TOP OF ROOTZONE 150mm ABOVE FINISHED GRADE OF SPECIFIED GROWING MEDIUM.

MIN

. 900

SPECIES PER PLANTING PLAN

INSTALL 50mm MULCH

TIMBER

CONIFEROUS TREE PLANTING ON SLAB (TYPICAL)Scale: 1:254

TREE ROOTBALL

50mm x 200mm TIMBER OR X-POTENTIAL DEADMAN

STAINLESS STEEL WIRE AND TURNBUCKLE

GALVANIZED STEEL STRAP BOLTED TO WOOD

MIN. 2x ROOT BALL

STRUCTURAL SLAB, SEE ARCHITECTURAL

FILTER FABRIC

ROOF ASSEMBLY, SEE ARCHITECTURAL

50mm WASHED SAND (FILTER LAYER)

INSTALL TOP OF ROOTZONE 150mm ABOVE FINISHED GRADE OF SPECIFIED GROWING MEDIUM.

ADJACENT CONDITIONS VARY PER PLANS

MIN

. 900

TIMBER

SPECIES PER PLANTING PLAN

INSTALL 50mm MULCH

REVISIONS

Project No.

Reviewed:

Drawn:

Scale:

06-537

Vancouver, British Columbia

OAK STREET

Conn

ect L

ands

cape

Arc

hite

ctur

e In

c.

ISSUED FOR REZONING 17-04-271

L3.0

AS SHOWN

KD

DS

LANDSCAPE DETAILSSOFTSCAPE

CONNECT LANDSCAPE ARCHITECTURE INC.

DOES NOT GUARANTEE THE EXISTENCE,

LOCATION, AND ELEVATION OF UTILITIES AND /

OR CONCEALED STRUCTURES AT THE PROJECT

SITE.

THE CONTRACTOR IS RESPONSIBLE FOR

DETERMINING THE EXISTENCE, LOCATION, AND

ELEVATION OF ALL UTILITIES AND / OR

CONCEALED STRUCTURES, AND IS

RESPONSIBLE FOR NOTIFYING THE

APPROPRIATE COMPANY, DEPARTMENT OR

PERSON(S) OF ITS INTENTION TO CARRY OUT ITS

OPERATIONS.

2305 Hemlock St, Vancouver BC, V6H 2V1T 604 681 3303 F 604 681 3307www.connectla.ca

Page 7: OAK STREET - Vancouver · coniferous tree planting on slab (typical) 4 scale: 1:25 tree rootball 50mm x 200mm timber or x-potential deadman stainless steel wire and turnbuckle galvanized

REVISIONS

Project No.

Reviewed:

Drawn:

Scale:

06-537

Vancouver, British Columbia

OAK STREET

Conn

ect L

ands

cape

Arc

hite

ctur

e In

c.

ISSUED FOR REZONING 17-04-271

L3.1

AS SHOWN

KD

DS

LANDCAPE DETAILSHARDSCAPE

CONNECT LANDSCAPE ARCHITECTURE INC.

DOES NOT GUARANTEE THE EXISTENCE,

LOCATION, AND ELEVATION OF UTILITIES AND /

OR CONCEALED STRUCTURES AT THE PROJECT

SITE.

THE CONTRACTOR IS RESPONSIBLE FOR

DETERMINING THE EXISTENCE, LOCATION, AND

ELEVATION OF ALL UTILITIES AND / OR

CONCEALED STRUCTURES, AND IS

RESPONSIBLE FOR NOTIFYING THE

APPROPRIATE COMPANY, DEPARTMENT OR

PERSON(S) OF ITS INTENTION TO CARRY OUT ITS

OPERATIONS.

2305 Hemlock St, Vancouver BC, V6H 2V1T 604 681 3303 F 604 681 3307www.connectla.ca

NOTES:1. EXPANSION JOINTS 6m O.C. MAX, CONTROL JOINTS @ 1.5m O.C. ADJUST TO SUIT SITE LAYOUT PLAN.2. ALL SCORELINES TO BE APPROVED BY LANDSCAPE ARCHITECT ON-SITE PRIOR TO INSTALLATION.

CIP CONCRETE ON GRADE (TYPICAL)Scale: 1:103

SAW CUT JOINT TYP. 6mm WIDE x 25mm DEEP; PATTERN VARIES , REFER TO PLAN

COMPACTED SUBGRADE

REINFORCE WITH #6 WMM

COMPACTED GRANULAR BASE 19mm MINUS CRUSHED GRAVEL OR AS SPECIFIED BY CIVIL

EXPANSION JOINT WITH SEALANT, TYPICAL

CIP CONCRETE FINISH PER SPECIFICATION

THICKEN CONCRETE AT EDGES

150

150

100

LAWN FLUSH WITH CONCRETE EDGE

VOID MATERIAL

MIN. 100mm DEPTH DRAIN ROCK SHALL BE 20mm DIAMETER, ROUND, WASHED & FREE OF CONTAMINANTS

0.6m x 1.8m PT TIMBER EDGE

BUILDING FACE

CONTINUOUS FILTER FABRIC STAPLED TO BACK OF 0.6m x 1.8m EDGER

DRAIN MAT OVER PROTECTION BOARD OVER WATERPROOFING SPECIFIED BY ARCHITECTURAL

GRAVEL DRAIN STRIP - ON SLABScale: 1:105

TEXADA HYDRAPRESSED SLAB PAVERSIZE : STANDARD (610MM X 610MM X 50MM)COLOUR : NATURALPATTERN : GRID (PER DETAIL 7B)SUPPLIED BY ABBOTSFORD CONCRETE PRODUCTS1.800.663.4091

PATIO PAVERSScale: 1:104

COLOR: NATURAL PATTERN: GRID

CONCRETE SLAB PAVERS

SWEEP JOINTS WITH SHARP JOINTING SAND AND VIBRATE IN

COMPACTED 20mm MINUS BASE GRAVEL

25mm BEDDING SAND

COMPACTED SUB-GRADE

2515

0

NOTE:USE CONCRETE HIDDEN EDGERESTRAINT WHEN PAVERS ARE NOTADJACENT TO A SOLID EDGE CONDITION.

STRUCTURAL SLAB, SEE ARCHITECTURAL

ROOF ASSEMBLY, SEE ARCHITECTURAL

SHARP JOINTING SAND IN JOINTS

60mm THICKNESS CONCRETE UNIT PAVERS

25mm BEDDING SAND

COMPACTED SUB-GRADE

150mm DEPTH OF 20mm MINUS BASE GRAVEL COMPACTED TO 95% MPD

20mm CLEAR CRUSH GRAVEL, 150mm DEPTH TYPICAL WHERE SPACE ALLOWS

STRUCTURAL VOIDING IF REQUIRED

ON SLAB

PEDESTRIAN / PATIO UNIT PAVINGScale: 1:101

STRUCTURAL SLAB - SEE ARCHITECTURAL

ROOF ASSEMBLY - DRAIN MAT, PROTECTION BOARD, WATERPROOF MEMBRANE BY OTHERS

ON GRADE

TYPE: CLASSIC STANDARD SERIESSIZE: 3:1 225mm x 75mm x 60mmPATTERN: RUNNING BONDCOLOR: CHARCOALSUPPLIER: ABBOTSFORD CONCRETE PRODUCTS VANCOUVER, BC1.800.663.4091

NOTE: ALL LUMBER SIZES ARE SHOWN AS NOMINAL

305EXTERIOR BUILDING FACE

0.6m x 1.8m P.T. TIMBER EDGE

MIN. 100mm DEPTH DRAIN ROCK SHALL BE 20mm DIAMETER, ROUND, WASHED & FREE OF CONTAMINANTS

0.6m x 1.8m P.T. TIMBER SPACER BRACE SET AGAINST EXTERIOR WALL & NAILED TO TIMBER EDGE

COMPACTED SUB-BASE OR UNDISTURBED SOIL

CONTINUOUS FILTER FABRIC STAPLED TO BACK OF 0.6m x 1.8m EDGER

PLANTING SOIL MIX: DEPTH TO VARY W/ PLANTING REQUIREMENTS

GRAVEL DRAIN STRIP - ON GRADEScale: 1:106

50

VA

RIE

S

ADJACENT PLANTING & SOIL

ADJACENT CONDITIONS VARY PER PLAN

CONCRETE RETAINING WALL WITH ARCHITECTURAL PAPERFORM FINISH. REFER TO STRUCTURAL FOR REINFORCING

SLAB CONNECTION PER ARCHITECTURAL AND STRUCTURAL

305

CIP CONCRETE RETAINING WALL (ON SLAB)Scale: 1:107

FLUSH CIP CONCRETE CAP - SMOOTH TROWEL ARCHITECTURAL FINISH AND 90 DEGREE CORNERS - CHAMFER 45°, TYPICAL

VAR

IES

- SE

E G

RA

DIN

G P

LAN

NOTE:1. GUARDRAIL REQUIRED FOR ALL WALLS ABOVE 610mm (2').

CIP CONCRETE FINISH PER SPECIFICATION

REINFORCE WITH #6 WMM

COMPACTED GRANULAR BASE, 19mm CLEAR CRUSH GRAVEL OR AS SPECIFIED BY CIVIL

SAW CUT JOINT TYP. 6mm WIDE x 25mm DEEP; PATTERN VARIES - REFER TO PLAN

EXPANSION JOINT WITH SEALANT, TYPICAL

THICKEN CONCRETE AT EDGES

STRUCTURAL SLAB, SEE ARCHITECTURAL

CIP CONCRETE ON SLAB (TYPICAL)Scale: 1:102

NOTES:1. EXPANSION JOINTS 6m O.C. MAX, CONTROL JOINTS @ 1.5m O.C. ADJUST TO SUIT SITE LAYOUT PLAN.2. ALL SCORELINES TO BE APPROVED BY LANDSCAPE ARCHITECT ON-SITE PRIOR TO INSTALLATION.

150 10

015

0

ROOF ASSEMBLY, SEE ARCHITECTURAL

150

915

75

SMALL TREE PER PLANTING PLAN

6" (152MM) CONCRETE PLANTER WALL WITH WWM REINFORCING

DOUBLE LAYER OF ROOT BARRIER - NILEX 950ES OR APPROVED EQUAL

LIGHT WEIGHT GROWING MEDIATIERRALITE GREEN ROOF MEDIA BY VERATEC OR APPROVED ALTERNATE

2" LAYER CLEAN WASHED SAND

1/2" THICK DRAIN MAT CONTINUOUS UNDER PLANTER

ADJACENT CONDITIONS PER PLAN

SEE ARCHITECTURAL FOR INSULATION AND MEMBRANE LAYERS OVER SLAB

TYPICAL ROOF PLANTERScale: 1:108

Page 8: OAK STREET - Vancouver · coniferous tree planting on slab (typical) 4 scale: 1:25 tree rootball 50mm x 200mm timber or x-potential deadman stainless steel wire and turnbuckle galvanized

REVISIONS

Project No.

Reviewed:

Drawn:

Scale:

06-537

Vancouver, British Columbia

OAK STREET

Conn

ect L

ands

cape

Arc

hite

ctur

e In

c.

ISSUED FOR REZONING 17-04-271

L3.2

AS SHOWN

KD

DS

LANDCAPE DETAILSFURNISHINGS

CONNECT LANDSCAPE ARCHITECTURE INC.

DOES NOT GUARANTEE THE EXISTENCE,

LOCATION, AND ELEVATION OF UTILITIES AND /

OR CONCEALED STRUCTURES AT THE PROJECT

SITE.

THE CONTRACTOR IS RESPONSIBLE FOR

DETERMINING THE EXISTENCE, LOCATION, AND

ELEVATION OF ALL UTILITIES AND / OR

CONCEALED STRUCTURES, AND IS

RESPONSIBLE FOR NOTIFYING THE

APPROPRIATE COMPANY, DEPARTMENT OR

PERSON(S) OF ITS INTENTION TO CARRY OUT ITS

OPERATIONS.

2305 Hemlock St, Vancouver BC, V6H 2V1T 604 681 3303 F 604 681 3307www.connectla.ca

ON SLAB

COMPACTED SUBGRADE

CONCRETE PAVING

BIKE RACK (TYPICAL)Scale: 1:202

ON GRADE

150mm (6”) DEPTH OF 20mm (3/4”) MINUS BASE GRAVEL COMPACTED TO 95% MPD

STRUCTURAL SLAB,SEE ARCHITECTURAL

ROOF ASSEMBLY,SEE ARCHITECTURAL

SURFACE MOUNT TABS WITH 5mm DIA. HOLES FOR ANCHORING. NON-CORROSIVE ANCHORING HARDWARE SEPARATE. REFER TO INSTALLATION GUIDE FOR DETAILS.

5mm DIA.

BOLT TO PAVING WITH HARDWARE SUPPLIED BY RACK MANUFACTURER

MODEL: MBR350FINISH: MATTE SILVER14BY: MAGLIN(1.800.716.5506)

PLAN

SECTION - ON GRADE

ADJACENT CONDITIONS PER PLAN

3/4" (20mm) MINUS BASE GRAVEL, 7" (180mm) DEPTH, COMPACTED TO 95% MPD

125 200mm (8”) THICK CONCRETE FOOTING OR PAD

COMPACTED SUBGRADE

GALVANIZED ANCHOR BOLTS PAINTED, COLOUR TO MATCH BENCH

800

250

200mm DEEP CONCRETE FOOTING, TYP.

1823

ADJACENT CONDITIONS PER PLAN

PLAN

BENCH (TYPICAL)Scale: 1:201

125

ADJACENT CONDITIONS PER PLAN

3/4" (20mm) MINUS BASE GRAVEL, 7" (180mm) DEPTH, COMPACTED TO 95% MPD

200mm (8”) THICK CONCRETE FOOTING OR PAD

STRUCTURAL SLAB, SEE ARCHITECTURAL

ROOF ASSEMBLY, SEE ARCHITECTURAL

GALVANIZED ANCHOR BOLTS PAINTED, COLOUR TO MATCH BENCH

SECTION - ON GRADE

MODEL: MLB1050-WFINISH: MATTE SILVER14, IPE WOODBY: MAGLIN(1.800.716.5506)

VARIES PER PLAN (MIN. 200MM)

ARCHITECTURAL ROOF ASSEMBLY OVER SLAB

610 [2'-0"] 457 [1'-6"] 305 [1'-0"]

CONCRETE STEP-LOGS3 TYPICAL SIZES, 35% SMALL, 45% MEDIUM, 20% LARGEPRINTS STAMPED INTO TOP SURFACE TO BE DETERMINED

CAST CONCRETE STEPPING 'LOGS'Scale: 1:203

C.I.P. OR PRECAST CONCRETE CYLINDERS WITH PRINTS IN SURFACE

FALL SURFACING PER DETAIL AND SPECIFICATIONS

INDIVUDUAL UNITS BURIED IN PLAY SURFACING AND SET ON STABLE LAYER;HEIGHT ABOVE GRADE VARIES FROM 150-300mm

DRAIN ROCK AND FILTER FABRIC AS SPECIFIED

TABLE AND CHAIRSScale: 1:204

MODEL: CATENA FREESTAND TABLEFINISH: STAINLESS STEELBY: LANDSCAPE FORMS1.800.430.6209

MODEL: CHIPMAN ARMED CHAIR, FREESTANDINGFINISH: STAINLESS STEELBY: LANDSCAPE FORMS1.800.430.6209