Upload
others
View
10
Download
0
Embed Size (px)
Citation preview
TR
UR
TVB
UP
UP
DN
DN
DN
OCC
376 SQ FT
200 GROSS
R-2
UNIT 5A
2
204
OCC
389 SQ FT
200 GROSS
R-2
UNIT 6A
2
205
OCC
301 SQ FT
200 GROSS
R-2
UNIT 4A
2
206
OCC
301 SQ FT
200 GROSS
R-2
UNIT 4A
2
207
OCC
312 SQ FT
200 GROSS
R-2
UNIT 7A
2
208
OCC
299 SQ FT
200 GROSS
R-2
UNIT 3A
2
209
OCC
299 SQ FT
200 GROSS
R-2
UNIT 3A
2
210
OCC
300 SQ FT
200 GROSS
R-2
UNIT 3A
2
211
OCC
302 SQ FT
200 GROSS
R-2
UNIT 3A
2
212
OCC
392 SQ FT
200 GROSS
R-2
UNIT 1A
2
218
OCC
318 SQ FT
200 GROSS
R-2
UNIT 2A
2
217
OCC
318 SQ FT
200 GROSS
R-2
UNIT 2A
2
216
OCC
318 SQ FT
200 GROSS
R-2
UNIT 2A
2
215
OCC
318 SQ FT
200 GROSS
R-2
UNIT 2A
2
214
OCC
385 SQ FT
200 GROSS
R-2
UNIT 10A
2
213
OCC
303 SQ FT
150 GROSS
B
OFFICE
3
201
OCC
299 SQ FT
15 NET
B
AMENITY
20
203
LOBBY
OCC
72 SQ FT
300 GROSS
S-1
TRASH
1
220
OCC
66 SQ FT
300 GROSS
S-1
ELEC
1
222
OCC
32 SQ FT
300 GROSS
S-1
STORAGE
1
219
R-257
28
2
G2.21
1
G2.21
ELEV.
OCC
124 SQ FT
150 GROSS
B
RESTROOM
1
221
> 1
/3 M
AX
OV
ER
ALL D
IAG
ON
AL D
IM.
42' -
4"
DIS
TA
NC
E B
ET
WE
EN
EX
ITS
FE
C
FE
C
FE
C
FE
C
108'-6" LONGEST EXIT ACCESS TRAVEL DISTANCE < 250' LIMIT PER TABLE 1017.2
2-HR EXTERIOR BEARING WALL FOR TYPE III-B CONSTRUCTION PER TABLE 601
2-HR FIRE BARRIER AT ELEVATOR HOISTWAY
ENCLOSURE CONNECTING 4 STORIES OR MORE PER SEC.
713.4 & SEC 713.14
2-HR FIRE BARRIER AT MECHANICAL SHAFTS PER SEC. 713.4
1-HR PROVIDED; EXCEEDS 1/2-HR FIRE PARTITION FOR CORRIDOR WALL IN
R-2 OCCUPANCY WITH SPRINKLER SYSTEM PER TABLE 1020.1
1-HR FIRE PARTITION SEPARATION BETWEEN UNITS
AND FROM OTHER OCCUPANCIES PER SEC. 420.2 & SEC. 708.3
20-MIN DOOR AT 1/2-HR RATED FIRE PARTITION PER
TABLE 716.1(2)
222
2
3
2 2
2
2
2
1
2
2
2
2
2
1
1
1
ELEV.
29
STAIR 02
STAIR 01
90-MIN FIRE DOOR PER TABLE 716.1(2): ALSO COMPLY WITH
SMOKE AND DRAFT CONTROL AT HOISTWAY PER 716.2.2.1.1
3
G2.21
2-HR FIRE BARRIER AT SHAFT ENCLOSURES CONNECTING 4 OR
MORE STORIES PER SEC. 713.4
90-MIN DOOR AT EXIT ENCLOSURES PER TABLE 716.1(2)
90-MIN DOOR AT EXIT ENCLOSURES PER TABLE 716.1(2)
OPEN TO BELOW
PROPERTY LINE
1
G2.22
2
G2.22
2-HR FIRE BARRIER AT SHAFT ENCLOSURES CONNECTING 4 OR
MORE STORIES PER SEC. 713.4
CO
RR
IDO
R
24' -
0"
DE
AD
EN
D
CORRIDOR
13' - 6" DEAD END
CORRIDOR
7' - 9" DEAD END
CO
RR
IDO
R
33' -
9"
DE
AD
EN
D
DIA
GO
NAL
DIM
.
125' -
4" M
AX O
VERALL
3' -
7 3
/4"
2-HR EXTERIOR BEARING WALL FOR TYPE III-B CONSTRUCTION PER TABLE 601
20
B
B
2
4
G2.21
FSD
14' - 0"
DEDICATED FIRE SPRINKLER
HEAD CENTERED ON EACH
OPENING; 6" MIN, 12" MAX FROM
INTERIOR SURFACE OF WINDOW;
12" MAX BELOW CEILING;
TYPICAL OF (7) AT EAST
EXTERIOR WALL, LEVEL 2
NON-FIRE RATED, FIXED
WINDOW; TYPICAL OF (5) AT
EAST EXTERIOR WALL, LEVEL 2
1 HOUR FIRE-RATED, SINGLE
HUNG WINDOW; TYPICAL OF (2) AT
EAST EXTERIOR WALL, LEVEL 2
NO-BUILD EASEMENT
5' -
4"
5' -
4"
DAS ROUTING
(3) DEDICATED FIRE SPRINKLER HEAD CENTERED ON EACH
OPENING; SPACED NOT MORE THAN 6' APART, 6" MIN, 12" MAX FROM
INTERIOR SURFACE OF WINDOW, AND 12" MAX BELOW CEILING
4' - 3" 4' - 3"
121-HOUR FIRE PARTITION- HORIZONTAL ASSEMBLY FOR SEPARATED OCCUPANCIES: S-2 SEPARATED FROM R-2- R-2 DWELLING UNITS SEPARATED FROM OTHER UNITS AND ADJACENT OCCUPANCIES
2-HOUR FIRE BARRIER- STAIR ENCLOSURES, ELEVATOR & SHAFTS
X PRIMARY OCCUPANCY GROUP
3
42TOTAL OCCUPANT LOAD FROM ROOM OR SPACE
OCCUPANT LOAD AT EXIT
EGRESS PATH - PROVIDE MINIMUM 1 FOOTCANDLE OF ILLUMINATED BY EGRESS LIGHTING - SEE ELECTRICAL
EXIT ACCESS TRAVEL DISTANCE
INDICATED LIGHTED EXIT SIGN, SEE ELECTRICAL FOR ADDITIONAL INFORMATION
FEC RATED & RECESSED FIRE EXTINGUISHER CABINET AT 75 FEET MAX
USE & OCCUPANCY:
1-HOUR HORIZONTAL ASSEMBLY- UNIT SEPARATIONS
FUNCTION OF SPACE PER 2019 OSSC TABLE 1004.5
OCCUPANCY LOAD
OCCUPANCY LOAD FACTOR
ROOM AREA
ROOM NUMBER101
ROOMROOM NAME
99 SQ FT100 NET/GROSS
1R-2
3-HR FIRE BARRIER- PODIUM SEPARATION
3-HR FIRE WALL- BUILDING SEPARATIONS (PER OSSC 706.1)
PRIMARY OCCUPANCY GROUPS (SEC. 302.1):
R-2 RESIDENTIAL (APARTMENTS)
S-1 STORAGE (TRASH, WATER, FIRE, ELEC.)(ACCESSORY <10% OF FLOOR SF)
B BUSINESS (AND ASSEMBLY WITH OCCUPANT LOAD <50) (MANAGER, RESIDENT SERVICES, OFFICES)
FDC
1-HOUR FIRE BARRIER- TRASH ENCLOSURES
REVISIONS:
PROJECT NO.
CO
PY
RIG
HT
-C
AR
LE
TO
N H
AR
T A
RC
HIT
EC
TU
RE
DO
NO
T R
EP
RO
DU
CE
WIT
HO
UT
PE
RM
ISS
ION
#
GENERAL NOTES:
LEGEND:
C A
R L
E T
O N
H
A R
T A
R C
H I T
E C
T U
R E
P
. C
.8 3
0
s w
1 0
t h
a v
e n
u e
# 2
0 0
p o
r t
l a
n d
o r
e g
o n
9 7
2 0
5
5 0
3 2 4
3 2 2
5 2
w
w w
. c a
r l e
t o
n h
a r
t . c
o m
FIRE LIFE SAFETYPLAN - LEVEL 2
05/28/2021
G2.02
CO
NF
OR
MA
NC
E S
ET
17004
SU
SA
N E
MM
ON
S -
NO
RT
H B
UIL
DIN
G680 N
W 1
8T
H A
VE
NU
E,
PO
RT
LA
ND
, O
R
NO
RT
HW
ES
T H
OU
SIN
G A
LT
ER
NA
TIV
ES
N
SCALE: 1/8" = 1'-0"1
FIRE LIFE SAFETY PLAN - LEVEL 2
OCCUPANT LOAD (PER OSSC 2019 SECTION 1004 AND TABLE 1004.5)
ROOMNUMBER ROOM NAME
PRIMARYOCC. FUNCTION AREA OLF OCC.
EXITSREQ'D
LEVEL 2
201 OFFICE B Business 303 SF 150 GROSS 3 1
203 AMENITY B Assembly without FixedSeats: Unconcentrated
299 SF 15 NET 20 1
204 UNIT 5A R-2 Residential 376 SF 200 GROSS 2 1
205 UNIT 6A R-2 Residential 389 SF 200 GROSS 2 1
206 UNIT 4A R-2 Residential 301 SF 200 GROSS 2 1
207 UNIT 4A R-2 Residential 301 SF 200 GROSS 2 1
208 UNIT 7A R-2 Residential 312 SF 200 GROSS 2 1
209 UNIT 3A R-2 Residential 299 SF 200 GROSS 2 1
210 UNIT 3A R-2 Residential 299 SF 200 GROSS 2 1
211 UNIT 3A R-2 Residential 300 SF 200 GROSS 2 1
212 UNIT 3A R-2 Residential 302 SF 200 GROSS 2 1
213 UNIT 10A R-2 Residential 385 SF 200 GROSS 2 1
214 UNIT 2A R-2 Residential 318 SF 200 GROSS 2 1
215 UNIT 2A R-2 Residential 318 SF 200 GROSS 2 1
216 UNIT 2A R-2 Residential 318 SF 200 GROSS 2 1
217 UNIT 2A R-2 Residential 318 SF 200 GROSS 2 1
218 UNIT 1A R-2 Residential 392 SF 200 GROSS 2 1
219 STORAGE S-1 Storage 32 SF 300 GROSS 1 1
220 TRASH S-1 Storage 72 SF 300 GROSS 1 1
221 RESTROOM B Business 124 SF 150 GROSS 1 1
222 ELEC S-1 Storage 66 SF 300 GROSS 1 1
TOTAL OCC. LOAD 57
A. SEE ATTCHED BUILDING CODE REVIEW DOCUMENT FORCODE SUMMARY INFORMATION INCLUDING OCCUPANTLOAD CALCULATIONS AND RATED WALL REQUIREMENTS
B. DAMPERS TO BE INSTALLED AS REQUIRED PER 2019OSSC SECTION 717, WHERE DUCTS OR AIR TRANSFEROPENINGS PENETRATE RATED ASSEMBLIES
C. MEANS OF EGRESS LIGHTING SHALL NOT BE LESS THAN1 FOOT CANDLE AT THE WALKING SURFACE.MAXIMUM-TO-MINIMUM ILLUMINATION UNIFORMITYRATIO NOT OT EXCEED 40:1. IN THE EVENT OF A POWERSUPPLY FAILURE, AN EMERGENCY ELECTRICAL SYSTEMSHALL AUTOMATICALLY ILLUMINATE THOSE EGRESSCOMPONENTS IDENTIFIED IN 2019 OSSC SECITON 1008.3FOR A MINIMUM OF 90 MIN. ILLUMINATION SHALLCONTINUE TO THE EXTERIOR LANDINGS OF ALL EGRESSDOORS.
D. IN ADDITION TO EXIT SIGN SHOWN ON FLS PLANS,PROVIDE EXIT SIGNS AS SHOWN ON THE ELECTRICALDRAWINGS
E. BUILDING TO BE SPRINKLERED THROUGHOUT PER NFPA13 WITH CLASS I, AUTOMATIC COMBINATION STANDPIPESYSTEM. AT LEAST ONE STANDPIPE TO TERMINATE ONTHE ROOF.
F. SEE SHEETS G3.01-G3.05 FOR RATED WALL ANDHORIZONTAL ASSEMBLIES
PER APPROVED BUILDING CODE APPEAL #24109 ITEM 3, IT IS ACCEPTABLE TO USE THE OCCUPANT LOAD OF AREAS NORMALLY OCCUPIED BY STAFF AND VISITORS TO CALCULATE THE REQUIRED QUANTITY OF PLUMBING FIXTURES. THIS ALLOWS FOR A SINGLE USER TOILET ROOM PER SECTION 2902 EXCEPTION 4. SEE BELOW FOR A SUMMARY OF THE APPROVED APPEAL:
AMENITY 203, LAUNDRY 321, AND LAUNDRY 521 ARE AMENITY SPACES OPEN TO RESIDENTS ONLY. IN ADDITION TO HAVING ACCESS TO COMMON AREA RESTROOMS, RESIDENTS OCCUPYING THESE SPACES WILL ALSO HAVE ACCESS TO RESTROOMS IN THEIR DWELLING UNITS. SEE BELOW FOR A SUMMARY OF THE SPACES IN THE BUILDING THAT ARE NORMALLY OCCUPIED BY STAFF AND VISITORS:
OFFICE 201, OCCUPANT LOAD: 2TOTAL: 2
THEREFORE (1) SINGLE USER TOILET ROOM IS PROVIDED FOR PUBLIC USE
12 PR #7 09/17/21