Tel (604) 576-1808 aeconcrete.com
Sales Office: Shipping: Page 1
19060-54th Avenue, Surrey, B.C. Canada V3S 8E5 5353-192nd Street, Surrey, B.C. Canada V3S 8E5
Oil Interceptor Listings Drawing Number Item Description Product Size
(Length X Width X Depth in mm)
Oil Interceptor / Separator Checklist
SALE-RS-ENQU-C Enquip Oil Stop Valve
Gravity Flow Stop Valves (Custom Built) Varies
BYPASS-LAYOUT-C Typical By-Pass Layout Varies
24OI-20-1420-API-C 2454 Oil Interceptor (API) c/w Baffles 1380 x 610 x 1065 i.d.
24OI-20-1420-CPS-C 2454 Oil Separator (CPS) c/w Baffles 1380 x 610 x 1065 i.d.
24OI-60-1420-C 2454 Steel Checker Plate Lid Varies
35OI-A0-1500-C 2454 / 355 Lid Assemblies
Roof Slab w/ 2-610Ø Openings (H-20 Traffic Load) Roof Slab w/ 243 Lid Assembly (H-20 Static Load - Boulevard)
1795 x 1190 x 188
35OI-20-1500-C 355 Oil Interceptor (API) c/w Baffles 1500 x 900 x 1525 i.d.
35OI-20-2400-API-C 385 Oil Interceptor (API) c/w Baffles 2395 x 900 x 1525 i.d.
35OI-20-2400-CPS-C 385 Oil Separator (CPS) c/w Baffles 2395 x 900 x 1525 i.d.
35OI-A2-2400-C 385 Roof Slab w/ Circular Openings (API) (H-20 Traffic Load) 2695 x 1190 x 188
35OI-AC-2400-C 385 Roof Slab w/ Circular Openings (CPS) (H-20 Traffic Load) 2695 x 1190 x 188
35OI-A6-2400-C 385 Roof Slab w/ 243 Lid Assembly (H-20 Static Load - Boulevard) 2695 x 1190 x 188
March 2018
Tel (604) 576-1808 aeconcrete.com
Sales Office: Shipping: Page 2
19060-54th Avenue, Surrey, B.C. Canada V3S 8E5 5353-192nd Street, Surrey, B.C. Canada V3S 8E5
Oil Interceptor Listings Drawing Number Item Description Product Size
(Length X Width X Depth in mm)
VCFI-OI-ZZZZ-API-C 251815 Firemeter Oil Interceptor & Roof Slab (API) c/w Baffles 2515 x 1825 x 1600 i.d.
VCFI-OI-ZZZZ-CPS-C 251815 Firemeter Oil Separator & Roof Slab (CPS) c/w Baffles 2515 x 1825 x 1600 i.d.
VCMC-OI-ZZZZ-API-C 332120 Meter Oil Interceptor & Roof Slab (API) c/w Baffles 3350 x 2130 x 1980 i.d.
VCMC-OI-ZZZZ-CPS-C 332120 Meter Oil Separator & Roof Slab (CPS) c/w Baffles 3350 x 2130 x 1980 i.d.
VC47-20-ZZZZ-API-C 4712 Oil Interceptor (API) c/w Baffles 4700 x 2125 x 2000 i.d.
VC47-20-ZZZZ-CPS-C 4712 Oil Separator (CPS) c/w Baffles 4700 x 2125 x 2000 i.d.
VC47-20-2500-API-C 472125 Oil Interceptor (API) c/w Baffles 4700 x 2125 x 2500 i.d.
VC47-20-2500-CPS-C 472125 Oil Separator (CPS) c/w Baffles 4700 x 2125 x 2500 i.d.
VC47-20-3000-API-C 472130 Oil Interceptor (API) c/w Baffles 4700 x 2125 x 3000 i.d.
VC47-20-3000-CPS-C 472130 Oil Separator (CPS) c/w Baffles 4700 x 2125 x 3000 i.d.
March 2018
API - American Petroleum Institute (3 Baffle Design) CPS - Coalescing Plate System Note: Most API Oil Interceptors can be upgraded to fit Facet Coalescing “M-Paks”. Riser sections available for extra depth. For more details on the Oil Separator Design, please contact the Sales Department. If you have a specific project, please send a completed Oil Interceptor / Separator Checklist and AE Concrete will submit a quotation to suit your project’s requirements.
Oil Interceptor / Separator Checklist
Cutomer: SO#: Date:
Job Name / PO#: TCSR:
Tank Details *Please indicate units of measurement for dimensions & elevations (mm, m, ft, in)
Model # (Inside Dimensions LxWxH): mm Custom Inside Dimensions (LxWxH):
Grade Elevation: Water Volume: liters
Inlet Elevation: Total Volume: liters
Static Water Elevation in Tank: Sediment Capacity: liters
Outlet Elevation: Oil Storage Capacity: liters
Floor Elevation:
Site Installation:
Other Components
Baffle Type:
Inlet Pipe Size: Inlet T-Pipe Required:
Outlet Pipe Size: Outlet Pipe Type:
Facet M-Pak Coalescing Plate System Required:
Application:
(Influent Oil Concentration)( ppm)
Desired Effluent Quality: Other: ppm Oil
Application Data
Liquid Type (SG@60ºF):
( )
Operating Temperature: min max Require Heated Unit?
Flow Rate: US gpm (1 liter/sec = 15.82032 US gpm)
Detergents / Soap in Use: Note: Detergents / Soap will reduce the effectiveness of the oil separation.
See Disclaimer on Quote
Flow Type:
If pumped, type of pump: Pumped Oil-Water Separator
Bypass Permissible:
Other Notes
l If upgrading an existing vault with facet, please Attach a Sketch with All INTERNAL Dimensions Shown (Length, Width & Total Depth).
l Cleaning Wand, Maintenance Manuals, Shop Drawings & Heat Cable Tags to be mailed as required.
Please complete this form with all available information & contact your AE Concrete Sales Representative at (604)576-1808 or [email protected]
No
No
After
Yes No
Sent
Yes
Oil Stop Valve T-Pipe
Jet Fuel (0.89)
Above Ground
Below Ground
Unfinished Steel
Galvanized Steel
Yes
Rainwater Runoff Retail Parking Lot (100 ppm)
Before or
Pumped
Yes
Refueling (200 ppm)
Engine Oil (0.80)
Transformer Oil (0.80)
Other
Indoors
Outdoors
Concrete
No
Other
Vehicle Maintenance / Washdown (400 ppm)
Diesel (0.85)
Other (SG)
Gravity Both
Yes No
<10 ppm <15 ppm
F:\Drawings\Catalogue Drawings\2017 Catalogue - AE Concrete\(07) Oil Interceptors\Oil Int-Sep Checklist (May2014).xlsm
Optional 90° Orientation
Right
Left
C
D
Inline Side View
Plan View - Mounting Plate
G
4"
1" 2"
3/4"Ø
Mounting PlateWelded to Bottom ofP-Trap Assy.
E
F
A
B
* Can Reduce to (2 x A + D) but may Affect High Flow Characteristics
*
General Notes:
⋅ Optional Epoxy Coated Steel or Stainless Steel Assy
⋅ Size - Range from 2" to 14" Pipe Diameters
⋅ P-Trap Assembly built to suit Application
⋅ Site Installation is the Responsibility of Others
Dwg#:
Rev:Scale:
19060 - 54th AvenueSurrey, B.C. V3S 8E5
Tel (604) [email protected]
Enquip Oil Stop Valve
NTS 27Apr18
SALE-RS-ENQU-C
Requested Dimension Standard (Minimum)
A Pipe Diameter
B Outlet Invert (B > 4 x A + D)
C 4 x A
D 2 x A + 1/4" (1.5 x A + 1/4")
E 6 x A (4 x A)
F As Required (Typ 600)
G A + 4"
Plan View - Layout
Side View - Layout
Important: All Pipe Inverts and Sizes must be designated to suit your application.
Roof Slab Removed for Clarity.
Bypass Manhole #1
Risers and/or Grouting to be Provided by Others.
Flow Direction
Inlet Outlet
Bypass Manhole #2
Dwg#:
Rev:Scale:
19060 - 54th AvenueSurrey, B.C. V3S 8E5
Tel (604) [email protected]
Typical Bypass Layout - Oil Interceptor
NTS 10Mar09
BYPASS-LAYOUT-C
Flow Direction
300 x 510K/O
225130
800
610
1065
250 880 250
1380
50Ø Vent Pipe(Typ 2)
1165
610
1570
810
Inlet Outlet
Typical Minimun Depthfrom Grade to Outlet Invert
with MH Castings = 835 mm
with Steel Lid = 455 mm
min
Plan View
Side View End View
100
General Notes:
⋅ Product manufactured in accordance with CSA A23.4
⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅ Designed for Roadway Use - H-20 Traffic Loading
⋅ Installation of T-Pipe Assemblies Recommended - Installed by Others.
⋅ Standard Mild Steel Baffles - Optional Galvanized Baffles
⋅ Up-gradable with Facet "M-Pak" Coalescing Plate System - Design/Build
⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others
Dwg#:
Rev:Scale:
19060 - 54th AvenueSurrey, B.C. V3S 8E5
Tel (604) [email protected]
2454 Oil Interceptor (API)
Oil Int: 2,610 lbs / 1,190 kgs 1:20 mm 28Jun08
24OI-20-1420-API-C
Flow Direction
225
130
800
610
1065
250 880 250
1380
50Ø Vent Pipe(Typ 2)
1165
610
1570
810
Side View End View
Facet M-Pak
Plan View
300 x 510K/O
Typical Minimum Depthfrom Grade to Outlet Invert
with MH Castings = 835 mm
with Steel Lid = 455 mm
min
Inlet Outlet
100
General Notes:
⋅ Product manufactured in accordance with CSA A23.4
⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅ Designed for Roadway Use - H-20 Traffic Loading
⋅ Installation of T-Pipe Assemblies Recommended - Installed by Others
⋅ Standard Mild Steel Baffles - Optional Galvanized Baffles
⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others
Dwg#:
Rev:Scale:
19060 - 54th AvenueSurrey, B.C. V3S 8E5
Tel (604) [email protected]
2454 Oil Separator (CPS)
Oil Sep: 2,610 lbs / 1,190 kgs 1:20 mm 28Jun08
24OI-20-1420-CPS-C
Painted Black, Steel Checker Plate LidsOptions: Galvanizing
25Ø Holes Weld Marking e.g. "ELEC"
Boulevard Use - H-20 Static Load Rated Lid
Plan View
General Notes:
⋅Product manufactured in accordance with CSA A23.4
⋅Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅Site Installation, Backfilling & Suitability for Use is the responsibility of others
Dwg#:
Rev:Scale:
19060 - 54th AvenueSurrey, B.C. V3S 8E5
Tel (604) [email protected]
2454 Steel Checker Plate Lid
Stl Chk Pl: 244 lbs / 111 kgs 1:20 mm 28Jun08
24OI-60-1420-C
Customizations:
Available for 355 & 385 Vaults
508Ø MH Casting (C-18)
181
1795
Plan View
Side View End View
188
660
1795
Plan View
Side View
188
End View
1270
(A) H-20 Traffic Load Rated Lid
(B) Boulevard Use - H-20 Static Load Rated Lid
1190
1190
620Ø Typ
Painted Black, Boltdown, Steel Checker Plate LidsOptions: Galvanizing, Padlock Recess
Remote Reader Holes Weld Marking e.g. "ELEC"
General Notes:
⋅ Product manufactured in accordance with CSA A23.4
⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others
Dwg#:
Rev:Scale:
19060 - 54th AvenueSurrey, B.C. V3S 8E5
Tel (604) [email protected]
2454 / 355 Lid Assemblies
Roof Slab: 1,620 lbs / 740 kgsRoof Slab w/ Hatch: 1,580 lbs / 720 kgs
1:25 mm 10Mar09
35OI-A0-1500-C
Typical Minimun Depthfrom Grade to Outlet Invert
with MH Castings = 980 mm
with Steel Lid = 800 mm
150
1125
495
600 x 600 x 75K/O
1780
1170
50Ø Vent Pipe(Typ 2)
1525
900
1500
915
1640
300 900 300
Flow Direction
Inlet Outlet
150
min
915
Side View
Plan View
End View
General Notes:
⋅ Product manufactured in accordance with CSA A23.4
⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅ Designed for Roadway Use - H-20 Traffic Loading
⋅ Installation of T-Pipe Assemblies Recommended - Installed by Others.
⋅ Standard Mild Steel Baffles - Optional Galvanized Baffles
⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others
Dwg#:
Rev:Scale:
19060 - 54th AvenueSurrey, B.C. V3S 8E5
Tel (604) [email protected]
355 Oil Interceptor (API)
1:25 mm 28Jun08
35OI-20-1500-C
Oil Int: 6,810 lbs / 3,100 kgs
Typical Minimun Depthfrom Grade to Outlet Invert
with MH Castings = 980 mm
with Steel Lid = 800 mm
915
Flow Direction1
12
5
150
600 x 600 x 75K/O
OutletInlet
1640
450 1495 450
900
2395
1525
2680
1170
150
min
915
495
Plan View
Side View End View
General Notes:
⋅Product manufactured in accordance with CSA A23.4
⋅Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅Designed for Roadway Use - H-20 Traffic Loading
⋅Installation of T-Pipe Assemblies Recommended - Installed by Others
⋅Standard Mild Steel Baffles - Optional Galvanized Baffles
⋅Up-gradable with Facet "M-Pak" Coalescing Plate System - Design/Build
⋅Site Installation, Backfilling & Suitability for Use is the responsibility of others
Dwg#:
Rev:Scale:
19060 - 54th AvenueSurrey, B.C. V3S 8E5
Tel (604) [email protected]
385 Oil Interceptor (API)
Oil Int: 9,460 lbs / 4,300 kgs 1:25 mm 28Jun08
35OI-20-2400-API-C
Typical Minimun Depthfrom Grade to Outlet Invert
with MH Castings = 980 mm
with Steel Lid = 800 mm
600 x 600 x 75K/O
915
Flow Direction
11
25
150
OutletInlet
1640
450 1495 450
900
2395
1525
1170
2680
150
min
495
Plan View
Side View End View
General Notes:
⋅ Product manufactured in accordance with CSA A23.4
⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅ Designed for Roadway Use - H-20 Traffic Loading
⋅ Installation of T-Pipe Assemblies Recommended - Installed by Others.
⋅ Standard Mild Steel Baffles - Optional Galvanized Baffles
⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others
Dwg#:
Rev:Scale:
19060 - 54th AvenueSurrey, B.C. V3S 8E5
Tel (604) [email protected]
385 Oil Separator (CPS)
Oil Sep: 9,460 lbs / 4,300 kgs 1:25 mm 28Jun08
35OI-20-2400-CPS-C
188
181
620Ø Typ
H-20 Traffic Load Rated
1190
2695
Plan View
Side View End View
508Ø MH Casting (C-18)
General Notes:
⋅Product manufactured in accordance with CSA A23.4
⋅Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅Designed for Roadway Use - H-20 Traffic Loading
⋅Site Installation, Backfilling & Suitability for Use is the responsibility of others
Dwg#:
Rev:Scale:
19060 - 54th AvenueSurrey, B.C. V3S 8E5
Tel (604) [email protected]
385 Roof Slab w/ Circular Openings
Roof Slab: 2,790 lbs / 1,270 kgs 1:25 mm 28Jun08
35OI-A2-2400-C
508Ø MH Casting (C-18)760Ø MH Casting (C-23/23A)
188
181
915Ø
620Ø
H-20 Traffic Load Rated
1190
2695
Plan View
Side View End View
General Notes:
⋅ Product manufactured in accordance with CSA A23.4
⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅ Designed for Roadway Use - H-20 Traffic Loading
⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others
Dwg#:
Rev:Scale:
19060 - 54th AvenueSurrey, B.C. V3S 8E5
Tel (604) [email protected]
385 Roof Slab w/ Circular Openings (CPS)
Roof Slab: 2,350 lbs / 1,070 kgs 1:25 mm 28Jun08
35OI-AC-2400-C
188
H-20 Static Load RatedBoulevard Use Only
660 1190410
4101270
2695
Plan View
SideView End View
Painted Black, Boltdown, Steel Checker Plate Lids
Options: Galvanizing, Padlock Recess Remote Reader Holes Weld Marking e.g. "ELEC"
General Notes:
⋅ Product manufactured in accordance with CSA A23.4
⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅ Designed for Boulevard (Off-Road) Use - H-20 Static Loading
⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others
Dwg#:
Rev:Scale:
19060 - 54th AvenueSurrey, B.C. V3S 8E5
Tel (604) [email protected]
385 Roof Slab w/ 243 Lid Assy
Roof Slab & Lid: 2,470 lbs / 1,130 kgs 1:25 mm 28Jun08
35OI-A6-2400-C
Flow Direction
508Ø MHCasting(C-18)
760Ø MHCasting(C-23)
2825
2130
2850
620Ø (Typ 2)
915Ø
2160
915
1300
150
600
16001740
1825
2515
225
181
1825
2515
508Ø MHCasting(C-18)
H-20 Traffic Load Rated
Typical Minimum Depthfrom Grade to Outlet Invertwith MH Castings = 1090 mm
min
Plan View - Chamber
End View
Plan View - Roof Slab
Side View
598 1320 597
150
General Notes:
⋅ Product manufactured in accordance with CSA A23.4
⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅ Designed for Roadway Use - H-20 Traffic Loading
⋅ Installation of T-Pipe Assemblies Recommended - Installed by Others
⋅ Standard Mild Steel Baffles - Optional Galvanized Baffles
⋅ Up-gradable with Facet "M-Pak" Coalescing Plate System - Design/Build
⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others
Dwg#:
Rev:Scale:
19060 - 54th AvenueSurrey, B.C. V3S 8E5
Tel (604) [email protected]
251815 Firemeter Oil Interceptor (API)
Oil Int:23,450 lbs / 10,640 kgs
1:50 mm 28Jun08
VCFI-OI-ZZZZ-API-C
Flow Direction
2825
2130
2850
620Ø (Typ 2)
915Ø
2160
915
16001740
225
181
600
1300
FacetM-Pak
1825
2515
508Ø MHCasting(C-18)
760Ø MHCasting(C-23
508Ø MHCasting(C-18)
H-20 Traffic Load Rated
min
Typical Minimum Depthfrom Grade to Outlet Invertwith MH Castings = 1090 mm
Plan View - Chamber
End View
Plan View - Roof Slab
Side View
598 1320
150
597
2515
1825150
General Notes:
⋅ Product manufactured in accordance with CSA A23.4
⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅ Designed for Roadway Use - H-20 Traffic Loading
⋅ Installation of T-Pipe Assemblies Recommended - Installed by Others
⋅ Standard Mild Steel Baffles - Optional Galvanized Baffles
⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others
Dwg#:
Rev:Scale:
19060 - 54th AvenueSurrey, B.C. V3S 8E5
Tel (604) [email protected]
251815 Firemeter Oil Separator (CPS)
Oil Sep:23,210 lbs / 10,690 kgs
1:50 mm 28Jun08
VCFI-OI-ZZZZ-CPS-C
3720
2500
230
181
915
200
1600 1980 2130
610Ø (Typ 2)
915Ø
1220
Flow Direction
508Ø MHCasting(C-18)
760Ø MHCasting(C-23/23A)
508Ø MHCasting(C-18)
H-20 Traffic Load Rated
863 1740 747
3350
2002130
3680
2460
2130
3350
min
Typical Minimum Depthfrom Grade to Outlet Invertwith MH Castings = 1170 mm
Side View End View
Plan View - Chamber Plan View - Roof Slab
General Notes:
⋅ Product manufactured in accordance with CSA A23.4
⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅ Designed for Roadway Use - H-20 Traffic Loading
⋅ Installation of T-Pipe Assemblies Recommended - Installed by Others
⋅ Standard Mild Steel Baffles - Optional Galvanized Baffles
⋅ Up-gradable with Facet "M-Pak" Coalescing Plate System - Design/Build
⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others
Dwg#:
Rev:Scale:
19060 - 54th AvenueSurrey, B.C. V3S 8E5
Tel (604) [email protected]
332120 Meter Oil Interceptor (API)
Oil Int:37,820 lbs / 17,170 kgs
1:50 mm 28Jun08
VCMC-OI-ZZZZ-API-C
3680 3720
2500
2460
230
181
915
200
1600 1980 2130
2130 610Ø (Typ 2)
915Ø
1220
Flow Direction
FacetM-Pak
3350
508Ø MHCasting(C-18)
760Ø MHCasting
(C-23/23A)
508Ø MHCasting(C-18)
H-20 Traffic Load Rated
Typical Minimum Depthfrom Grade to Outlet Invertwith MH Castings = 1170 mm
min
Side View End View
Plan View - Chamber Plan View - Roof Slab
200
863 1739 748
3350
2130
General Notes:
⋅ Product manufactured in accordance with CSA A23.4
⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅ Designed for Roadway Use - H-20 Traffic Loading
⋅ Installation of T-Pipe Assemblies Recommended - Installed by Others
⋅ Standard Mild Steel Baffles - Optional Galvanized Baffles
⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others
Dwg#:
Rev:Scale:
19060 - 54th AvenueSurrey, B.C. V3S 8E5
Tel (604) [email protected]
332120 Meter Oil Separator (CPS)
Oil Sep: 37,720 lbs / 17,170 kgs 1:50 mm 28Jun08
VCMC-OI-ZZZZ-CPS-C
Flow Direction
915
250
1600
1220 1220
181
1000
1000
4700
2125
610Ø 915Ø (Typ 2)
508Ø MHCasting(C-18)
760Ø MHCasting(C-23)
508Ø MHCasting(C-18)
H-20 Traffic Load Rated
300
910 2890 900
Typical Minimum Depthfrom Grade to Outlet Invertwith MH Castings = 1240 mm
min
Plan View - Top
Side View End View
Plan View - Bottom
5010
2485
1280
1180
General Notes:
⋅ Product manufactured in accordance with CSA A23.4
⋅ Designed for Roadway Use - H-20 Traffic Loading
⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅ Installation of T-Pipe Assemblies Recommended - Installed by Others
⋅ Standard Mild Steel Baffles - Optional Galvanized Baffles
⋅ Up-gradable with Facet "M-Pak" Coalescing Plate System - Design/Build
⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others
Dwg#:
Rev:Scale:
19060 - 54th AvenueSurrey, B.C. V3S 8E5
Tel (604) [email protected]
4712 Oil Interceptor (API)
Oil Int: 51,180 lbs / 23,230 kgs 1:60 mm 28Jun08
VC47-20-ZZZZ-API-C
915
250
1600
1220FacetM-Pak 1220
181
1000
1000
4700
2125
508Ø MHCasting(C-18)
760Ø MHCasting(C-23)
508Ø MHCasting(C-18)
H-20 Traffic Load Rated
Flow Direction
610Ø 915Ø (Typ 2)
300
910 2890 900
Side View End View
Typical Minimum Depthfrom Grade to Outlet Invertwith MH Castings = 1240 mm
min
Plan View - Top Plan View - Bottom
5010
2485
1280
1180
General Notes:
⋅ Product manufactured in accordance with CSA A23.4
⋅ Designed for Roadway Use - H-20 Traffic Loading
⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅ Installation of T-Pipe Assemblies Recommended - Installed by Others
⋅ Standard Mild Steel Baffles - Optional Galvanized Baffles
⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others
Dwg#:
Rev:Scale:
19060 - 54th AvenueSurrey, B.C. V3S 8E5
Tel (604) [email protected]
4712 Oil Separator (CPS)
Oil Sep:51,180 lbs / 23,230 kgs
1:50 mm 28Jun08
VC47-20-ZZZZ-CPS-C
2125
4700
610Ø (Typ 2)
915Ø
Flow Direction
915
300
2220
1830
1250
1250
508Ø MHCasting(C-18)
760Ø MHCasting(C-23)
508Ø MHCasting(C-18)
H-20 Traffic Load Rated
400
1005 2800 905
1530
1430
Typical Minimum Depthfrom Grade to Outlet Invertwith MH Castings = 1130 mm
min
Plan View - Top Plan View - Bottom
5010
2485
Side View End View
General Notes:
⋅ Product manufactured in accordance with CSA A23.4
⋅ Designed for Roadway Use - H-20 Traffic Loading
⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅ Installation of T-Pipe Assemblies Recommended - Installed by Others.
⋅ Standard Mild Steel Baffles - Optional Galvanized Baffles
⋅ Up-gradable with Facet "M-Pak" Coalescing Plate System - Design/Build
⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others
Dwg#:
Rev:Scale:
19060 - 54th AvenueSurrey, B.C. V3S 8E5
Tel (604) [email protected]
472125 Oil Interceptor (API)
Oil Int: 57,050 lbs / 25,890 kgs 1:60 mm 28Jun08
VC47-20-2500-API-C
508Ø MHCasting(C-18)
760Ø MHCasting(C-23)
508Ø MHCasting(C-18)
2125
915
300
2220
1830
1250
1250
4700
FacetM-Pak
H-20 Traffic Load Rated
400
1005 2800 905
Side View End View
610Ø (Typ 2)
915Ø
Flow Direction
Typical Minimum Depthfrom Grade to Outlet Invertwith MH Castings = 1130 mm
min
Plan View - Top Plan View - Bottom
5010
2485
1530
1430
General Notes:
⋅ Product manufactured in accordance with CSA A23.4
⋅ Designed for Roadway Use - H-20 Traffic Loading
⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅ Installation of T-Pipe Assemblies Recommended - Installed by Others
⋅ Standard Mild Steel Baffles - Optional Galvanized Baffles
⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others
Dwg#:
Rev:Scale:
19060 - 54th AvenueSurrey, B.C. V3S 8E5
Tel (604) [email protected]
472125 Oil Separator (CPS)
Oil Sep: 57,050 lbs / 25,890 kgs 1:60 mm 28Jun08
VC47-20-2500-CPS-C
2125
4700
915Ø 610Ø (Typ 2)
915
300
2620
2720
1500
1500
508Ø MHCasting(C-18)
760Ø MHCasting(C-23)
508Ø MHCasting(C-18) 181
Flow Direction
H-20 Traffic Load Rated
950 2860
200
910
1780
1680
Typical Minimum Depthfrom Grade to Outlet Invertwith MH Castings= 1020 mm
min
Side View End View
Plan View - Top Plan View - Bottom
2485
5010
General Notes:
⋅ Designed for Roadway Use - H-20 Traffic Loading
⋅ Product manufactured in accordance with CSA A23.4
⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅ Installation of T-Pipe Assemblies Recommended - Installed by Others
⋅ Standard Mild Steel Baffles - Optional Galvanized Baffles
⋅ Up-gradable with Facet "M-Pak" Coalescing Plate System - Design/Build
⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others
Dwg#:
Rev:Scale:
19060 - 54th AvenueSurrey, B.C. V3S 8E5
Tel (604) [email protected]
472130 Oil Interceptor (API)
Oil Int: 63,590 lbs / 28,860 kgs 1:60 mm 28Jun08
VC47-20-3000-API-C
2125
4700
915
300
2620
2720
1500
1500
508Ø MHCasting(C-18)
760Ø MHCasting(C-23)
508Ø MHCasting(C-18)
181
2485
5010
H-20 Traffic Load Rated
950 2860
200
910
Side View End View
915Ø 610Ø (Typ 2)
Flow Direction
Typical Minimum Depthfrom Grade to Outlet Invertwith MH Castings = 1020 mm
min
Plan View - Top Plan View - Bottom
1780
1680
General Notes:
⋅ Product manufactured in accordance with CSA A23.4
⋅ Designed for Roadway Use - H-20 Traffic Loading
⋅ Lift Points Provided (See Shop Drawing for Quantity & Locations)
⋅ Installation of T-Pipe Assemblies Recommended - Installed by Others
⋅ Standard Mild Steel Baffles - Optional Galvanized Baffles
⋅ Site Installation, Backfilling & Suitability for Use is the responsibility of others
Dwg#:
Rev:Scale:
19060 - 54th AvenueSurrey, B.C. V3S 8E5
Tel (604) [email protected]
472130 Oil Separator (CPS)
Oil Sep: 63,590 lbs / 28,860 kgs 1:60 mm 28Jun08
VC47-20-3000-CPS-C