Olympus Automation Guide Olympus Automation Guide www.prior.com More to Prior than meets the eye

Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

Embed Size (px)

Citation preview

Page 1: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

1 Olympus Automation GuideOlympus Automation Guide

Olympus Automation Guide

www.prior.com

More to Prior than meets the eye

Page 2: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

1 www.prior.com

Introduction

This brochure is designed to provide an overview of the equipment we produce for a range of Olympus microscopes.

Please note that the equipment in this guide is not an exhaustive list and instead shows the more common products that can be mounted on these microscopes. Additionally, other Olympus microscopes can have Prior equipment added to them.

More information about our products can be found by contacting a Prior representative, emailing [email protected] or by visiting www.prior.com.

We also have an extensive collection of datasheets which are freely available on our website (www.prior.com), or via contacting Prior Scientific.

The parts to be selected will depend both upon the microscope make and the end-user’s application.

We highly recommend contacting a Prior Sales Manager before ordering.

At the end of this guide you will find a short explanation of our stage codes.

Please note that the parts may vary in availability and part numbers and specifications may change without warning. Whilst we have attempted to verify that the information here is accurate, we cannot guarantee that it is completely up to date and error free; thus we suggest contacting Prior before ordering in order to ensure that all equipment will be compatible with your microscope and suitable for your application. The microscopes featured here are for illustrative purposes only. All intellectual property relating to these microscopes, including patents and trademarks, remain the property of their respective owners. Olympus is a registered trademark of Olympus Corporation. ProScan®, OptiScan® and ZDeck® and the Prior Scientific logo are registered trademarks of Prior Scientific Ltd. The 5 year warranty applies to stages used with a Prior controller, for full details, terms and conditions of the warranty please visit Prior.com. This document is © Prior Scientific 2017. Olympus Sales Brochure July 2017 V.1.6.

Page 3: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

2 Olympus Automation Guide

Products listed in green on the systems charts require the ProScan ® III Control System to be

operated

Contents

Olympus IX 73/83 3Olympus BX series 7Olympus BX51/61WI 11Olympus MVX-10 15ProZ Stand (for MVX10, MX and BX microscopes) 19Olympus MX Series 23Stage Guide 27

Page 4: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

3 www.prior.com

Focus Motor- PS3H122R + H807- PS3H122R + H807 + H122KBIX (direct coupling)

NanoScanZ Sample holders- NZ303 (NZ400)- NZ302 (NZ400)- NZ301 (NZ400)

Incubation chambers for NanoScanZ- W3719 (NZ400)(Control unit included)

Sample holders- H473XR- H223XRNC- H229XR-H224XRLP

Incubation chambers - W3561 - W4184(Control unit included)

Motorised stages - H117P1XD- H117E1XD

(Option to add extension wings - H117ACCM)

Linear stages - HLD117IX

Adapters- H4100- H4101

H139 Stages- H139P1XD- H139E1XD

H139 Sample holders- H171XR- H223XR2- H473R3

IX73/83

Page 5: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

4 Olympus Automation Guide

Lumen 100- L100###OL(Replace ###

with wavelength)

Brightfield- LDB102OL- LDB103OL

Shutters- HF200HT (Excitation) - HF201HT (Excitation) - HF202HT + HF235 (Excitation)- HF204HT + HF235 (Excitation)- HF204HT + HF238 (Transmitted)

Lumen 200 - L200SIX- L220SIX

NanoScan Z stages- NZ400

Lumen 200 - L200IX

Joystick Control Units-PS3J100

Filter wheels- HF110A + HF235 (Excitation)- HF110A + HF236 (Emission)- HF108A + HF235 (Excitation)- HF1081X3 (Emission on breadboard)

Controllers*- ES10ZE - V31XYZE- V31F- V31XYZEF- VLD31XYZ- VLD31XYZF *Compatible with mostimaging software

Breadboard (only)-H3948

H139 Stages- H139P1XD- H139E1XD

IX73/83

Page 6: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

5 www.prior.com

Product Details

ES10ZE Focus only system controllerH117ACCM Stage extension wings for H117 stage H117E1XD H117 motorised stage with 1mm screw pitch and encodersH117P1XD H117 motorised stage with 1mm screw pitch H122KBIX Direct Fine Focus coupling kitH139P1N4 H139 motorised stage with 1 mm ballscrew, 400 stepper motorH139E1N4 H139 motorised stage with 1 mm ballscrew, 400 stepper motor and 50 nm encoderH171XR 9 slide holder for H139H223XRNC Extra recessed microtitre plate for H117 stagesH223XR2 2 micro titre plate holder for H139H224XRLP Extra recessed low profile slide holder for H117 stages H229XR Extra recessed petri dish holder for H117 stagesH3948 Olympus BreadboardH4100 Required for when adding a H117 stage on an IX73 with a motorised DIC unitH4101 Required for when adding a H117 stage on an IX83 with a motorised DIC unitH473XR Extra recessed low profile universal holder for H117 stagesH473XR3 Double Universal sample holder for H139H807 Focus sleeve for IX and BX microscopesHF108IX3 Breadboard filter wheel 8 position, 32mm diameter filter for Olympus IX3HF108A/HF235 Filter wheel holding 8 32 mm filters with adapter (Excitation)HF110A/HF235 Filter wheel holding 10 25mm filters with adapter (Excitation)HF110A/HF236 Filter wheel holding 10 25mm filters with adapter (Emission)HF200HT High speed shutter with 25mm aperture for use with filter wheelHF201HT High speed shutter with 32mm aperture for use with filter wheelHF202HT/HF235 High speed shutter with 25mm aperture for stand alone use, with adapter (Excitation)HF204HT/HF238 High speed shutter with 32 mm aperture for stand alone use with adapter (Transmission) HF204HT/HF235 High speed shutter with 32mm aperture for stand alone use, with adapter (Excitation)HLD117IX Linear motor stageL100###OL Single LED illumination system. Replace ### with wavelength requiredL200IX Metal Halide Illumination Source

IX73/83

Page 7: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

6 Olympus Automation Guide

Product Details

L200SIX Metal Halide Illumination Source with integral shutter.L220IX Metal Halide Illumination Source with extended UV/IR wavelengthsL220SIX Metal Halide Illumination Source with integral shutter and with extended UV/IR wavelengths LDB102OL Brightfield LED illumination (standalone)LDB103OL Brightfield LED illumination (controlled via ProScan)NZ301 Well plate holder for NZ400NZ302 Slide/petri dish holder for NZ400NZ303 Slide holder for NZ400NZ400 Nanopositioning piezo Z stage with 400 um of travel and controllerPS3H122R Focus drivePS3J100 Multifunctional manual joystick for ProScanV31F ProScan® Controller with three stepper drives for filters, shutters or a focus driveV31XYZE ProScan® Controller with X Y Z drives and encoder capabilityV31XYZEF ProScan® controller with XYZ drives, three filter wheel drives, three shutter drives and encoder capabilityVLD31XYZ ProScan® controller with XYZ drives for linear stage controlVLD31XYZF ProScan® controller with XYZ drives, three filter wheel drives, and three shutter drives for linear stage control. W3561 Incubation chamber for H117 stagesW3569 Incubation chamber for NZ100/200W3719 Incubation chamber for NZ400W4184 Incubation chamber for H117 stages

IMPORTANT:

The IX83 is motorised and so a focus motor cannot be added to it

The IX71 is similar in terms of which Prior equipment has been added, however the IX81 requires different stages (see the stage guide at the end of this booklet)

IX73/83

Page 8: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

7 www.prior.com

NanoScanZ3

- NZ200F

Sample holders- H224LP- H473UP

Slide Loader- PL2001

- PL2382 OR PL2282

- PL304Motorised stages - H101BX- HIP4BX- HEP4BX- PL101BX1 - PLE01BX1,2

Flat top Motorised stages - H101E1BX/B3 - H101P1BX/B3- H101P2BX/B3

B3 stages are for use with BX63 microscopes with pillar mounts.

Flat top stage sample holders- H224F- H234F

Sample holder adapter

Focus Motor- PS3H122R + H807- PS3H122R + H807 + H122KBIX (direct coupling)

BX53/BX63

Brightfield- LDB102OL- LDB103OL

Page 9: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

8 Olympus Automation Guide

Lumen 100- L100###OL

(Replace ### with wavelength)

Controllers- ES10ZE - V31XYZE- V31F- V31XYZEF Compatible with mostimaging software

Filter wheels- HF108A/HF235 (Excitation)- HF110A/HF235 (Excitation)- HF110A/HF239 (Emission)

Lumen 200 - L220SOL- L200SOL

Joystick Control Unit- PS3J100

Shutters- HF200HT (Excitation)- HF201HT (Excitation)- HF202HT/HF235 (Excitation)- HF204HT/HF238 (Transmitted)- HF204HT/HF235 (Excitation)

Lumen 200 - L220OL- L200OL

BX53/BX63

Page 10: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

9 www.prior.com

Product Details

ES10ZE Focus only controllerH101BX H101A stage with 2mm screw pitch and 200 step motorH101E1B3 H101F flat top stage with 1 mm screw pitch, 200 step motors and encoders (BX63 with pillar mount only)H101E1BX H101F flat top stage with 1 mm screw pitch, 200 step motors and encodersH101P1B3 H101F flat top stage with 1 mm screw pitch and 200 step motors (BX63 with pillar mount only)H101P1BX H101F flat top stage with 1mm screw pitch and 400 step motorsH101P2B3 H101F Flat top stage with 2mm screw pitch and 200 step motor (BX63 with pillar mount only)H101P2BX H101F flat top stage with 2mm screw pitch and 200 step motors.H1P4BX H101A stage with 1 mm screw pitch and 400 step motorH122KBIX Direct Fine Focus coupling kitH224F Low profile slide holder for flat top stagesH224LP Low profile slide holder H234F Low profile slide holder (4 slides) for flat top stagesH3848 Allows H101 sample holders to be fitted to a flat top stageH473UP Universal sample holderH807 Focus sleeve for IX and BX microscopes HEP4BX H101A stage with 1mm screw pitch, 400 step motor and encodersHF108A/HF235 Filter wheel holding 8 32mm filters with adapter (Excitation)HF110A/HF235 Filter wheel holding 10 25mm filters with adapter (Excitation)HF110A/HF239 Filter wheel holding 10 25mm filters with adapter (Emission)HF200HT High speed shutter with 25 mm aperture for use with filter wheel Excitation)HF201HT High speed shutter with 32 mm aperture for use with filter wheel (Excitation)HF202HT/HF235 High speed shutter with 25 mm aperture for stand alone use (Excitation)HF204/HF238 High speed shutter with 32mm aperture for stand alone use (Transmitted)HF204HT/HF235 High speed shutter with 32 mm aperture for stand alone use (Excitation)L100###OL Single LED illumination system. Replace ### with wavelength requiredL200OL Metal Halide Illumination Source L200SOL Metal Halide Illumination Source with integral shutterL220OL Metal Halide Illumination Source with extended UV/IR wavelengthsL220SOL Metal Halide Illumination Source with integral shutter with extended UV/IR wavelengths

BX53/BX63

Page 11: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

10 Olympus Automation Guide

IMPORTANT:

1. The slide loader can only be used with the PL101ABX or PLE01ABX stages

2. The PLE01ABX is only for use with the PL228

3. NZ200F can only be used with flat top stages

The BX63 is motorised so it is not possible to add focus motors to it

Product Details

LDB102OL Brightfield LED illumination (standalone)LDB103OL Brightfield LED illumination (controlled via ProScan)NZ200FCE Nanopositioning piezo Z stage with 200 µm of travel and controller; adapted for flat top stagesPL101BX H101A stage for use with Slide LoaderPLE01BX Encoded H101A stage for use with Slide LoaderPL200 Slide LoaderPL228 Bevel edged sample holder for “1 x 3” slides. Includes 4 slide racks for for “1 x 3” slidesPL238 Bevel edged sample holder for “2 x3” slides. Includes 2 slide racks for “2 x 3” slides.PL304 Barcode reader for PL200PLE01ABX Encoded H101A stage for use with Slide Loader (use with PL228 only)PS3H122R Focus drive PS3J100 Multifunctional manual joystick for ProScanV31F ProScan® controller with three stepper drives for focus and two filter wheels or 3 shuttersV31XYZE ProScan® controller with XYZ drives and encoder inputV31XYZEF ProScan® controller with XYZ drives, three filter wheel drives, shutter drives and encoder input

BX53/BX63

Page 12: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

11 www.prior.com

NanoScanZ1

- NZ200F

Sample holders- H224LP- H473UP

Z-Deck adapterHZ201

Motorised stages - H117P1XD- H117E1XD(Option to add extension wings- H117ACCM)

NanoScan Z stages- NZ400

NanoScanZ Sample holders- NZ303 (NZ400)- NZ302 (NZ400)- NZ301 (NZ400)

Sample holders- H473XR- H223XRNC- H229XR-H224XRLP

Z-Deck- ZDP 12MP- ZDP12ME- ZDP12MK- ZDP12MF

Z-Deck Sample Holders- HZ202- HZ204

- PS3H122R + H807- PS3H122R + H807 + H122KBIX (direct coupling)

BX51WI/BX61WI

Page 13: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

12 Olympus Automation Guide

Lumen 100- L100###OL(Replace ### with wavelength)

Controllers*- ES10ZE - V31XYZE- V31F- V31XYZEF *Compatible with mostimaging software

Filter wheels- HF108A/HF235 (Excitation)- HF110A/HF235 (Excitation)- HF110A/HF239 (Emission)

Lumen 200

- L220SOL- L200SOL

Joystick Control Unit- PS3J100

Shutters- HF200HT (Excitation)- HF201HT (Excitation)- HF202HT/HF235 (Excitation)- HF204HT/HF238 (Transmitted)- HF204HT/HF235 (Excitation)

Lumen 200 - L220OL- L200OL

- PS3H122R + H807- PS3H122R + H807 + H122KBIX (direct coupling)

BX51WI/BX61WI

Brightfield- LDB102OL- LDB103OL

Page 14: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

13 www.prior.com

Product Details

ES10ZE Focus only controllerH117ACCM Stage extension wings for H117 stage H117E1XD H117 motorised stage with 1mm screw pitch and encodersH117P1XD H117 motorised stage with 1mm screw pitch H122KBIX Direct Fine Focus CouplingH223XRNC Extra recessed microtitre plate for H117 stagesH224XRLP Extra recessed low profile slide holder for H117 stages H229XR Extra recessed petri dish holder for H117 stagesH224LP Low profile slide holder H471XR Extra recessed slide insert for NZ100/200H472XR Extra recessed 35mmpetri dish for NZ100/200H473UP Universal sample holderH499XR Recessed Universal Specimen Holder (NZ100/200) H807 Focus sleeve for IX and BX microscopes HF108A/HF235 Filter wheel holding 8 32mm filters with adapter (Excitation)HF110A/HF235 Filter wheel holding 10 25mm filters with adapter (Excitation)HF110A/HF239 Filter wheel holding 10 25mm filters with adapter (Emission)HF200HT High speed shutter with 25 mm aperture for use with filter wheel (Excitation)HF201HT High speed shutter with 32 mm aperture for use with filter wheel (Excitation)HF202HT/HF235 High speed shutter with 25 mm aperture for stand alone use (Excitation)HF204/HF238 High speed shutter with 32mm aperture for stand alone use (Transmitted)HF204HT/HF235 High speed shutter with 32 mm aperture for stand alone use (Excitation)HZ201 Adapter allowing upright sample holders to be inserted into Z-DeckHZ202 Solid Insert Plate for Z-DeckHZ204 110 mm ring insert plate for Z-DeckL100###OL Single LED illumination system. Replace ### with wavelength required.L200OL Metal Halide Illumination Source L200SOL Metal Halide Illumination Source with integral shutterL220OL Metal Halide Illumination Source with extended UV/IR wavelengthsL220SOL Metal Halide Illumination Source with integral shutter with extended UV/IR wavelengths

BX51WI/BX61WI

Page 15: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

14 Olympus Automation Guide

IMPORTANT:

NZ200F can only be used with the Z-Deck

Z-Deck only suitable for BX51/61WI microscopes.

Product Details

LDB102OL Brightfield LED illumination (standalone)LDB103OL Brightfield LED illumination (controlled via ProScan)NZ200FCE Nanopositioning piezo Z stage with 200 um of travel and controller; adapted for flat top stagesNZ400 Nanopositoning piezo Z stage with 400 um of travelNZ301 Well plate holder for NZ400NZ302 Slide/petri dish holder for NZ400NZ303 Slide holder for NZ400NZ400 Nanopositioning piezo Z stage with 400 um of travel and controllerPS3H122R Focus drive and adapterPS3J100 Multifunctional manual joystick for ProScanV31F ProScan® controller with three stepper drives for focus and two filter wheels or 3 shuttersV31XYZE ProScan® controller with XYZ drives and encoder inputV31XYZEF ProScan® controller with XYZ drives, three filter wheel drives, shutter drives and encoder inputZDP12MP Motorised Z-Deck quick adjust platform system ZDP12ME Motorised Z-Deck quick adjust platform system (Encoded)ZDP12MK Manual Z-Deck quick adjust platform systemZDP12MF Fixed plate Z-Deck quick adjust platform system

BX51WI/BX61WI

Page 16: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

15 www.prior.com

NanoScanZ1

- NZ200F

Sample holders- H224LP- H473UP

Motorised stages2 - H101BX- HIP4BX- HEP4BX

Flat top Motorised stages2 - H101E1BX - H101P1BX - H101P2BX

Flat top stage sample holders- H224F- H234F

Sample holder adapter H3848

MVX10

Brightfield- LDB102OL- LDB103OL

Page 17: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

16 Olympus Automation Guide

Lumen 100- L100###OL(Replace ### with wavelength)

Controllers*- V31XYZE- V31F- V31XYZEF *Compatible with mostimaging software

Filter wheels- HF108A/HF235 (Excitation)- HF110A/HF235 (Excitation)- HF110/32A/HF235 (Excitation)- HF110A/HF260 (Emission)- HF108A/HF260 (Emission)- HF110/32A/HF260 (Emission)

Lumen 200 - L220SOL- L200SOL

Joystick Control Unit- PS3J100

Shutters- HF200HT (Excitation)- HF201HT (Excitation)- HF202HT/HF235 (Excitation)- HF204HT/HF235 (Excitation)

Lumen 200 - L220OL- L200OL

MVX10

Page 18: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

17 www.prior.com

Product Details

H101BX H101A stage with 2mm screw pitch and 200 step motorH101E1BX H101F flat top stage with 1 mm screw pitch, 200 step motors and encodersH101P1BX H101F flat top stage with 1mm screw pitch and 400 step motorsH101P2BX H101F flat top stage with 2mm screw pitch and 200 step motorsH1P4BX H101A stage with 1 mm screw pitch and 400 step motorH224F Low profile slide holder for flat top stagesH224LP Low profile slide holder H234F Low profile slide holder (4 slides) for flat top stagesH3848 Allows H101 sample holders to be fitted to a flat top stageH473UP Universal sample holderHEP4BX H101A stage with 1mm screw pitch, 400 step motor and encodersHF108A/HF235 Filter wheel holding 8 32mm filters with adapter (Excitation)HF110A/HF235 Filter wheel holding 10 25mm filters with adapter (Excitation)HF110/32A/HF235 Filter wheel holding 10 32 mm filters with adapter (Excitation) HF108A/HF260 Filter wheel holding 8 32mm filters with adapter (Emission)HF110/32A/HF260 Filter wheel holding 10 32 mm filters with adapter (Emission) HF110A/HF260 Filer wheel holding 10 25 mm filters with adapter (Emission) HF200HT High speed shutter with 25 mm aperture for use with filter wheel (Excitation)HF201HT High speed shutter with 32 mm aperture for use with filter wheel Excitation)HF202HT/HF235 High speed shutter with 25 mm aperture for stand alone use (Excitation)HF204HT/HF235 High speed shutter with 32 mm aperture for stand alone use (Excitation)HF260 Adapter for emission (mounts under trinocular head)L100###OL Single LED illumination system. Replace ### with wavelength requiredL200OL Metal Halide Illumination Source L200SOL Metal Halide Illumination Source with integral shutterL220OL Metal Halide Illumination Source with extended UV/IR wavelengthsL220SOL Metal Halide Illumination Source with integral shutter with extended UV/IR wave lengthsLDB102OL Brightfield LED illumination (standalone)LDB103OL Brightfield LED illumination (controlled via ProScan)

MVX10MVX10

Page 19: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

18 Olympus Automation Guide

IMPORTANT:

1 NZ200F can only be used with flat top stages

2 To mount this stage, please use a SZX-STAD2 base (available from Olympus)

Product Details

NZ200F Nanopositioning piezo Z stage with 400 um of travel and controller; adapted for flat top stagesPS3J100 Multifunctional manual joystick for ProScanV31F ProScan® controller with three stepper drives for focus and two filter wheels or 3 shuttersV31XYZE ProScan® controller with XYZ drives and encoder inputV31XYZEF ProScan® controller with XYZ drives, three filter wheel drives, shutter drives and encoder input

MVX10MVX10

Page 20: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

19 www.prior.com

Filter wheels- HF108A/HF235 (Excitation)- HF110A/HF235 (Excitation)- HF110A/HF239 (Emission)

Lumen 200 - L220OL- L200OL

Shutters- HF200HT (Excitation)- HF201HT (Excitation)- HF202HT/HF235 (Excitation)- HF204HT/HF238 (Transmitted)- HF204HT/HF235 (Excitation)

Lumen 200 - L220SOL- L200SOL

Lumen 100- L100###OL

Adapter for MVX series

- ZCAMVX-ZCAMVXS (for use with ZC12EL, contact Prior if using SZX microscope)

Controllers- ES10ZE - V31XYZE- V31F- V31XYZEFCompatible with most imaging software

Joystick Control Units - PS3J100

Clamping Arms

Pillar Mounting Adapter-ZC12FLNG

ProZ Stand

Page 21: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

20 Olympus Automation Guide

Motorised stages- H101- HIP4- HEP4-H105/N2F

Large Format Motorised stages - H116/2 - HE16/2 - H112/2ST - HE12/2ST8

Sample holders- H224LP (H101 stages)- H473UP (H101 stages)- H230 (H101 stages)- H220 (H101 stages)- H227 (H105 stages)- H231 (H105 stages)- H225 (H116 stages)- H232 (H116 stages)- H233 (H112 stages)- H221 (H112 stages)

Adapter for BX/MX series- ZCABX

ProZ Stand- ZC12- ZC12EL - ZC12FL

Mounting stand- H413- H414 (for usewith ZC12EL)

Stage mount

-ZCBRL-ZCBTL (for transmitted light, BX only)

Adapter for BX-HP1770

Focus Blocks- FB201- FB203- FB204/E- FB205/E- FB206/E

Pillar Mounting Adapter-ZC12FLNG

ProZ Stand

Brightfield- LDB102OL- LDB103OL

Page 22: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

21 www.prior.com

Product Details

ES10ZE Focus only controllerFB201 Manual focussing blockFB203 Motorised Linear AxisFB204 Motorised focus holding an incident light Prior stage; with flanges for fitting to optical tableFB204E As above with EncodersFB205 Motorised focus with offset base holding an incident light Prior stage with flanges for fitting to optical tableFB205E As above with encodersFB206 Motorised focus holding a transmitted light Prior stage with flanges for fitting to optical tableFB206E As above with encodersH101 H101A stage with 2mm screw pitch and 200 step motorH105/N2F Large format stage with 154 x 154 mm travel range, 200 step motors and 2 mm screw pitchH112/2ST Large format stage with 302 x 302 mm travel range, 200 stepper motor and 2 mm screw pitchH116/2 Large format stage with 255 x 215 mm travel range, 200 stepper motor and 2 mm screw pitchH1P4 H101A stage with 1 mm screw pitch and 400 step motorH220 Glass plate (H101 stages) - not suitable for transmitted microscopyH221 Glass plate (H112 stages) - not suitable for transmitted microscopyH224LP Low profile slide holder (H101 stages)H225 Glass plate (H116 stages) - not suitable for transmitted microscopyH227 Glass plate (H105 stages) - not suitable for transmitted microscopyH230 Aluminium plate (H101 stages)H231 Aluminium plate (H105 stages)H232 Aluminium plate (H116 stages)H233 Aluminium plate (H112 stages)H413 Mounting stand for H105 or H101 stage H414 Mounting stand for H112 or H116 stageH473UP Universal sample holder (H101 stages)HE05/2 Encoded variant of H105/2HE12/2ST Encoded variant of H112/2STHE16/2 Encoded variant of H116/2HEP4 H101A stage with 1mm screw pitch, 400 step motor and encodersHF108A/HF235 Filter wheel holding 8 32mm filters with adapter (Excitation)HF110A/HF235 Filter wheel holding 10 25mm filters with adapter (Excitation)HF110A/HF239 Filter wheel holding 10 25mm filters with adapter (Emission)HF200HT High speed shutter with 25 mm aperture for use with filter wheel (Excitation)

ProZ Stand

Page 23: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

22 Olympus Automation Guide

Product Details

HF201HT High speed shutter with 32 mm aperture for use with filter wheel (Excitation)HF202HT/HF235 High speed shutter with 25 mm aperture for stand alone use (Excitation)HF204/HF238 High speed shutter with 32mm aperture for stand alone use (Transmitted)HF204HT/HF235 High speed shutter with 32 mm aperture for stand alone use (Excitation)HP1770 Adapter for BX microscopes L100###OL Single LED illumination system. Replace ### with wavelength required.L200OL Metal Halide Illumination Source L200SOL Metal Halide Illumination Source with integral shutter.L220OL Metal Halide Illumination Source with extended UV/IR wavelengthsL220SOL Metal Halide Illumination Source with integral shutter with extended UV/IR wavelengthsLDB102OL Brightfield LED illumination (standalone)LDB103OL Brightfield LED illumination (controlled via ProScan)PS3J100 Multifunctional manual joystick for ProScanV31F ProScan® controller with three stepper drives for focus and two filter wheels or 3 shuttersV31XYZE ProScan® controller with XYZ drives and encoder inputV31XYZEF ProScan® controller with XYZ drives, three filter wheel drives, shutter drives and encoder inputZC12 Motorised Z column with 500 mm2 base and 250 mm of travelZC12EL Motorised Z column with approx 600 x 750 mm base and 250 mm of travel ZC12FL Motorised Z column with no base and 250 mm of travel ZC12FLNG Adapter for mounting ZC12FL to optical mounting table ZCABX Optical mounting arm for RFA illumination (BX series only)ZCAMVX Optical mounting arm for MVX-10ZCAMVXS Extended arm for MVX-10 ZCBCK Universal clamping kit for illumination basesZCBRL H101, H105 stage mount reflected light only. Add HP1770 for manual stage dovetail optionZCBTL Prior H101, H105 stage mount transmitted light. Accepts 50mm diffuser/filter. Includes Prior LDB101 LED light source

Notes Note that H116 and H112 stages require ZC12EL and H414

ProZ Stand

Page 24: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

23 www.prior.com

Large Format Motorised stages255 x 215 mm- H116/2- HE16/2

Large Format Motorised stages300 x 300 mm- H112/2ST- HE12/2ST

Large Format Motorised stages154 x 154 mm- H105/N2F

Sample holders for H105 stages - HWC15SNL (H105)- HWC15VNL (H105)- H231 (H105)- H227 (H105)

MX

Page 25: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

24 Olympus Automation Guide

Sample holders for H112 stages - H233 (H112)- H233B (H112)- H221 (H112)- HWC30S (H112)

Sample holders for H116 stages - H225 (H116)- H232 (H116)- HWC20S (H116)- HWC20V (H116)

Laser Autofocus- LF210- LF100K- LF335

Controllers- ES10ZE - V31XYZE- V31F- V31XYZEF Compatible with mostimaging software

Joystick Control Unit- PS3J100

Focus Motor- PS3H122R + H807

MX

Brightfield- LDB102OL- LDB103OL

Page 26: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

25 www.prior.com

Product Details

ES10ZE Focus only controllerH105/N2F Stage with 154 x 154 mm travel range and 2 mm ball screwH116/2 Stage with 225 x 215 mm travel range and 2 mm ball screwHE16/2 As above with encodersH112/2ST Stage with 300 x 300 mm travel range and 2 mm ball screwHE12/2ST As above with encodersH221 Glass Plate (H112 stages) - not suitable for transmitted microscopy H225 Glass plate (H116 stages) - not suitable for transmitted microscopyH227 Glass plate (H105 stages) - not suitable for transmitted microscopyH231 Aluminium plate (H105 stages)H232 Aluminium plate (H116 stages)H233 Aluminium plate (H122 stages)H233B Aluminium plate with M4 and M6 tapped holes (H112 stages)HWC15SNL Wafer chuck for 100 and 150 mm wafers (H105 stages)HWC15VNL Wafer chuck, rotatable with vacuum for 150 mm (H105 stages)HWC20S Wafer chuck for for 150 mm and 200 mm wafers (H116 stages)HWC20V Wafer chuck, rotatable with vacuum for 200 mm wafers (H116 stages) HWC30S Wafer chuck, rotatable, for 300 mm wafers (H112 stages)LDB102OL Brightfield LED illumination (standalone)LDB103OL Brightfield LED illumination (controlled via ProScan)LF100K Laser Autofocus Control KeypadLF210 Laser Autofocus for reflective specimens. Requires LF100K and LF335.LF335 Flange to fit LF210 to MX microscopesPS3H122R/H807 Focus drive and adapterPS3J100 Multifunctional manual joystick for ProScanV31F ProScan® controller with three stepper drives for focus and two filter wheels or 3 shuttersV31XYZE ProScan® controller with XYZ drives and encoder inputV31XYZEF ProScan® controller with XYZ drives, three filter wheel drives, shutter drives and encoder input

NOTE THAT DIFFERENT MX VARIANTS CANACCOMMODATE DIFFERENT SIZED STAGES

MX50 - H105/N2F AND H116 SeriesMX50L - H105/N2F AND H116 AND H112 seriesMX51 - H105/N2F ONLYMX61 - H105/N2F AND H116 AND H122MX61L - H105/N2F AND H116 AND H112

MX

Page 27: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

26 Olympus Automation Guide

NOTES

Page 28: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

27 www.prior.com

This guide can be used to quickly identify the exact product code for our stages. Many of our stages can fit to a variety of microscopes and can be configured in various ways.

To ensure that the correct stage is manufactured and delivered, it is essential that the correct product code be provided.

We highly recommend that you contact a Prior Sales Manager prior to ordering.

Please note that this is a guide relevant to commonly used, relatively recent research microscopes. For less common, more specialised, or older microscopes, contact Prior Scientific.

This indicates the ballscrew of the stage:

1: 1 mm ballscrew2: 2 mm ballscrew

This indicates whether the stage is encoded or not:

P: Not currently encoded (upgrade available)E: Encoded

H101F FLAT TOP STAGE

H101P2FThis indicates the microscope type

the stage is suitable for:

F: No microscope specifiedBX: Olympus (general)B3: Olympus (BX63 microscope w/pillars)

This indicates whether the stage is encoded or not:

1: Not currently encoded (upgrade available)E: Encoded

H138A STAGE

H138A

Stage Codes

Page 29: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

28 Olympus Automation Guide

This indicates whether the stage is encoded or not:

P: Not currently encoded (upgrade available)E: Encoded

H117 STAGE

H117E1XD

For IX81 microscopes, the stage required has a different

code!

H117E1I4This indicates whether the stage is encoded or not:

P: Not currently encoded (upgrade available)E: Encoded

This indicates the ballscrew of the stage:

0: 2 mm ballscrewP: 1 mm ballscrew

This indicates whether the stage is encoded or not;

1: Not currently encoded (upgrade available)E: Encoded

H101A STAGE

H101BX This indicates the stepper motor of the stage:

1: 200 stepper motor4: 400 stepper motor

Stage Codes

Page 30: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

29 www.prior.com

This indicates whether the stage is encoded or not:

1: Not currently encoded (upgrade available)E: Encoded

H112 STAGE

H112/2STThis indicates the pitch ball screw;

2: 2 mm ballscrew pitch5: 5 mm ballscrew pitch

This indicates whether the stage is encoded or not:

1: Not currently encoded (upgrade available)E: Encoded

H116 STAGE

H116/2OLThis indicates the pitch ball screw:

2: 2 mm ballscrew pitch5: 5 mm ballscrew pitch

Stage Codes

H105 STAGE FOR UPRIGHT MICROSCOPES

H105/N2F There are currently no encoded variants for the H105/N2F.

Page 31: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

30 Olympus Automation Guide

This indicates what drives the Z deck:P: Stepper Motor (Unencoded)E: Stepper Motor (Encoded)K: Manual controlF: Fixed (no movement possible)

Z-DECK ELECTROPHYSIOLOGY STAGE

ZDP12MPThis indicates which microscope the Z-Deck is

adapted to:

P: Olympus BX51WI/BX61WIN: Nikon NiE/FN1L: Leica Z: Zeiss Axio Examiner

This indicates whether the stage is encoded:

1: Not currently encoded (upgrade available)E: 50 nm encoders

H139 MULTI-WELL PLATE STAGE

H139#1XD

Stage Codes

Page 32: Olympus - Prior Scientific · 2 Olympus Automation Guide Products listed in green on the systems charts require the ProScan ® III Control System to be operated Contents Olympus IX

31 www.prior.com

Since 1919 Prior Scientific has been producing precision equipment for microscopy. With decades of experience, expert staff, a vast range of products and extensive design, manufacture and assembly facilities, Prior Scientific can supply equipment for all manner of microscopy applications.

More to Prior than meets the eye

WORLDWIDE DISTRIBUTION

Prior Scientific LtdCambridge • UK

t: +44 (0)1223 881711e: [email protected]

Prior Scientific IncRockland • MA. • USA

t: +1 781-878-8442 e: [email protected]

Prior Scientific GmbH Jena • Germany

t: +49 (0) 3641 675 650e: [email protected]

Prior Scientific KK Tokyo • Japan

t: +81-3-5652-8831e: [email protected]