9
A Hilco Global Company Vested in Your Success Electrical Equipment, Chemical Process Equipment, Industrial Supply & Polysilicon Production Equipment from a 4000 Metric Ton Poly-Silicon Production Facility Online Bidding Opens: Friday, October 30 th Online Bidding Closes: Wednesday, November 4 TH Pocatello, Idaho ONLINE AUCTION Phone +1 248-254-9999 www.hilcoind.com Sale Offered in Partnership with www.perryvidex.com HilcoTM Industrial www.hackmancapital.com 3rd SALE IN A SERIES OF AUCTIONS

ONLINE AUCTION - Windows · PDF fileProduction Equipment from a 4000 Metric Ton Poly-Silicon Production Facility Online Bidding Opens: Friday ... GAS COMPRESSORS • HEAT EXCHANGERS

  • Upload
    doanthu

  • View
    231

  • Download
    6

Embed Size (px)

Citation preview

Page 1: ONLINE AUCTION - Windows · PDF fileProduction Equipment from a 4000 Metric Ton Poly-Silicon Production Facility Online Bidding Opens: Friday ... GAS COMPRESSORS • HEAT EXCHANGERS

A Hilco Global CompanyVested in Your Success

Electrical Equipment, Chemical ProcessEquipment, Industrial Supply & Polysilicon

Production Equipmentfrom a

4000 Metric Ton Poly-Silicon Production Facility

Online Bidding Opens: Friday, October 30th

Online Bidding Closes: Wednesday, November 4TH

Pocatello, Idaho

ONLINE AUCTION

Phone +1 248-254-9999

www.hilcoind.com

Sale Offered in Partnership with

www.perryvidex.com

HilcoTM Industrial

www.hackmancapital.com

3rd SALE IN A SERIES OF AUCTIONS

Page 2: ONLINE AUCTION - Windows · PDF fileProduction Equipment from a 4000 Metric Ton Poly-Silicon Production Facility Online Bidding Opens: Friday ... GAS COMPRESSORS • HEAT EXCHANGERS

To schedule an auction, please call Hilco Industrial  at 1-877-37-HILCO (44526)2

ONLINE AUCTIONHilcoTM Industrial

ONLINE BIDDING OPENS

FRIDAY, OCTOBER 30TH

BEGINNING AT 10AM LOCAL TIME

ONLINE BIDDING CLOSES

WEDNESDAY, NOVEMBER 4TH

CHeCk www.HIlCoInd.Com For ClosInG tImes

PREVIEwMONDAY & TUESDAY, NOVEMBER 2ND & 3RD

8AM TO 4PM LOCAL TIME to sCHedUle An eArlIer InspeCtIon, pleAse ContACt BrIAn lee At 203-258-0927 or emAIl [email protected]

ASSET LOCATION1 HOKU WAY POCATELLO, ID 83204

DIRECTIONSFROM SALT LAKE CITY INTERNATIONAL AIRPORT: EXIT AIRPORT TO I-80 E TO I-215 N,THEN MERGE ONTO I-15 N (APPROX. 92 MILES) TAKE EXIT 71 FOR POCATELLO CREEK RDAND TURN LEFT, CONTINUE ON TO E ALAMEDA RD, THEN TURN LEFT ONTO N MAIN ST.TURN RIGHT ONTO N KRAFT RD, THEN LEFT ONTO HOKU WAY.

FURTHER INFORMATION• AN 18% BUYER'S PREMIUM WILL BE CHARGED ON ALL ASSETS. THE BUYER’S

PREMIUM WILL BE REDUCED TO 16% FOR PAYMENTS MADE BY MEANS OF CASH,CASHIER’S CHECK, COMPANY CHECK (WITH BANK LETTER OF GUARANTEE) ORWIRE TRANSFER WITHIN 48 HOURS OF SALE CLOSE. PAYMENT WILL NOT BEACCEPTED ON SITE. AUCTION WILL BE CONDUCTED IN ENGLISH, ACCEPTING U.S.CURRENCY ONLY.

• REMOVAL DEADLINE IS FRIDAY, NOVEMBER 20TH, WITH HOURS OF REMOVAL BETWEEN8AM TO 4PM MONDAY THRU FRIDAY. BUYERS WITH ITEMS LEFT ON SITE AFTER DEAD-LINE ARE SUBJECT TO FINES OF $500 PER DAY.

MACHINERY &  EQUIPMENT

BRIAN LEE 203-258-0927 • [email protected] INFORMATION

LESIA JOSEPH 616-328-6892 • [email protected] ACCOUNTS RECEIVABLE AT [email protected] SERVICE

+1 877-37-HILCO • +1 616-732-1800 • [email protected]

Information contained herein deemed to be accurate at time of printing and subject to change. For updated information, please visit our website at www.hilcoind.com for any changes to

date, sale process, terms and conditions and list of available assets.

2009

POLYSILICON PRODUCTION

REACTORS16 – GERHARD-RAUH CHEMICAL VAPOR

DISPOSITION REACTORS, S/N 50086(All 2009), 24-Rod Bell Jar, w/ Stand &Base Plate

8 – GERHARD-RAUH HYDROGENATIONREACTORS, (2008/2009), (ConvertsSTC Gas to TCS Gas) w/ Inner Bell Jar &Base Plate

REACTORS

Page 3: ONLINE AUCTION - Windows · PDF fileProduction Equipment from a 4000 Metric Ton Poly-Silicon Production Facility Online Bidding Opens: Friday ... GAS COMPRESSORS • HEAT EXCHANGERS

3

SLIM ROD PULLERS • COLUMNS

For more information, please visit us on the web at www.hilcoind.com/Hoku

POLYSILICON PRODUCTION, cont.SLIM ROD PULLERS9 – PVA TEPLA MODEL SR-110 SLIM ROD PULLERS, Capable

Of Creating 7mm Dia. x 2800mm Long Polysilcon Rods FromPolysilicon Source Ingots, w/ Trumpf HF7015 RF Generator,Stainless Steel Water Cooled Dual-Wall Work Chambers,Stainless Steel Water Cooled Feed Rod Shafts, Pull Lengths upto 3.2 Meters, Vacuum/ Argon Dry Seals with Low Maintenanceand High Purity, Digital Motion Control with High Accuracy PullRates, Touch Screen Operator Panel, Electronic Gas PressureController, Electro-Polished Gas Piping System, OverDimensioned Mechanical, Parts for Long Lifetime, RFGenerator Comprising Over Dimensioned High Power, RatedComponents, Dimensions Dependent on Arrangement – WidthApprox. 1800mm, Depth Approx. 4000mm, Height Approx.6430mm, Weight Approx. 5600kg (Net)

1 – PVA TEPLA MODEL FZ-14M FLOAT ZONE PULLER, PolyRod Dia. Up To 30mm, Poly Rod Length Up To 300mm, PullingLength 350mm Upper & Lower Spindles, Pulling Speed 0-30mm/min Upper & Lower Spindles, Fast Travel Speed 100-300mm/min Upper & Lower Spindles, Spindle Rotation 0-10 rpm Upper & 0.05 rpm Lower, 15 kw RF Generator

QUANTITY OF Assorted Seed Rods w/ Graphite Chucks

CHEMICAL PROCESSINGCOLUMNS2 – EATON (2) SECTION HCL DISTILLATION COLUMNS, S/Ns 16991, 16993 (Both 2009),MAWP Internal

320 PSIG @ 400° F, MAWP External 15 PSIG @ 150° F, MDMT -30° F @ 320 PSIG, Stainless Steel TopSection, 36" ID x 17/ 4.5" High, Design Pressure 260 PSI @ 400° F, Bottom Section, 84" ID x 34' 10"High, Design Pressure 300 PSI @ 400° F, Insulated w/ Catwalk & Access Ladders

2 – KENNEDY RECOVERY TOWERS, MAWP Int. 90 PSI @ 150° F, MAWP Ext. FV @ 150° F, MDMT -30°F @ 90 PSI/FV, Overall Length 46', Tower Length 23' 6", Cone Bottom

2 – HARRIS THERMAL TRANSFER 12" DIA. X 113' DISTILLATION COLUMNS, (Both 2011), CarbonSteel Construction, MAWP Int. 373 PSIG @ 450° F, MAWP Ext. 15 PSIG @ 190° F, MDMT -30° F @ 300 PSIG, Mounted On Skirt

2 – JETT WELD 3' DIA. X 129' SEPARATION COLUMNS, (Both 2009), Carbon Steel Construction,MAWP Int. 214 PSIG @ 360° F, MAWP Ext. 15 PSIG @ 280° F, O.D. 36.75", Wall Thickness .375",Flanged Bottom Mounted On Skirt, (2) Boxes Stainless Steel Floating Valve Type Tray Parts

2 – EATON STAINLESS STEEL HCL ABSORBER COLUMNS, (Both 2009), 48" Dia. x 46' 9" High, MAWPInt. 285 PSIG @ 150° F, MAWP Ext. 15 PSIG @ 150° F, MDMT -50° F @ 285 PSIG, Degign Pressure260 PSI @ 150° F

1 – KENNEDY TANK COLUMN (2011), Carbon Steel Construction. 2'6" Diameter x 34'4", (2) 410 StainlessSteel Sieve Trays, Intalox Ultra Packing Packed Bed. 150 PSI/Full Vacuum @ 450°F

4 – JETT WELD 36" X 120' DISTILLATION COLUMNS, (All 2009), Carbon Steel Construction, MAWP Int.216 PSIG @ 360° F, MAWP Ext. 15 PSIG @ 265° F, MDMT -30° F @216 PSI, O.D. 36.75", Wall Thickness.375", Flanged Bottom Mounted On Skirt, (3) Boxes Stainless Steel Floating Valve Type Tray Parts

2 – ARMSTRONG ENGINEERING VERTICAL STAINLESS STEEL TYPE G BAYONET VAPORIZERS,TUBE IN TUBE HEAT EXCHANGERS, (Both 2010), 16" Dia. x 11' 3" Long, MAWP Int. Shell 600 PSIG@ 400° F, Tube 150 PSIG @ 400° F, MAWP Ext, Shell & Tube 15 PSIG @ 400° F, MDMT, Shell -50° F@ 600 PSIG, Tube -20° F @ 150 PSIG

Register & Bid Online Only at

hilcoind.com/Hoku

Page 4: ONLINE AUCTION - Windows · PDF fileProduction Equipment from a 4000 Metric Ton Poly-Silicon Production Facility Online Bidding Opens: Friday ... GAS COMPRESSORS • HEAT EXCHANGERS

GAS COMPRESSORS • HEAT EXCHANGERS • OIL / FLUID HEATERS

To schedule an auction, please call Hilco Industrial  at 1-877-37-HILCO (44526)4

2009

CHEMICAL PROCESSING, cont.GAS COMPRESSORS6 – NEUMAN & ESSER MODEL 1TZS190 GAS COMPRESSORS (All 2009), 7742 CFM. Reciprocating

Type. 57.8 PSIG Suction Pressure, 201 PSI Final Pressure. (3) Induction Hyundai 900 HP ElectricMotor, 4000 Volts, 151.6 Amp, 60 Hz. Vent Gas Recovery Process

4 – HOWDEN MODEL P123LG280/17 REGENERATION GAS COMPRESSORS, Reciprocating Type.17.7 PSIG Suction Pressure, 102 PSIG Discharge Pressure. 40 HP Electric Motor. Skid Mounted withPiping, Heat Exchanger, and Control Panel, Charged with Freon

2 – GEA FES MODEL 1160SE CHILLER COMPRESSORS (Both 2009), Skidded Package, Type R-507Refrigerant, Water Cooled w/ Model 1160S Series Compressor, TECO Westinghouse 2250 HP Motor,2300/4160 Volt, 3578 RPM, Pressure Vessel w/ Top Mounted Heat Exchanger, (2) Viking 15 HPRecirculating Pumps

2 – GEA FES MODEL 1160S/385S 2-STAGE CHILLER COMPRESSORS (Both 2009), Skid Mounted w/ #1160S/385S Gas Compressors, G Force Touch Screen Control, Utilizes R507 Refrigerant, EachCompressor Is Driven By a 600 HP 4000 Volt Motor, #1160S Compressor Mounted on Top of a 36" Dia.x 186" Oil Separator, #385S Compressor Mounted Beside The Separator, 12" Dia. x 120" Oil Cooler,(2) 100 GPM Oil Pumps

2 – GEA FES MODEL 1160S/385S 2-STAGE CHILLER COMPRESSORS, (Both 2009), Skid Mounted w/#1160S/385S Gas Compressors, G Force Touch Screen Control, Utilizes R507 Refrigerant, EachCompressor Is Driven By a 600 HP 4000 Volt Motor, #1160S Compressor Mounted On Top Of A 36"Dia. x 186" Oil Seperator, #385S Compressor Mounted Beside The Separator, 12" Dia. x 120" OilCooler, (2) 100 GPM Oil Pumps

GAS CONSOLES7 – INTEGA GAS CONSOLES, For Nitrogen, Hydrogen & TCS Gases,

Consisting of: 2" Samson Diaphragm Regulating Valve, (2) 1" SamsonDiaphragm Regulating Valves, (3) 2" Stohr 1200 Pneumatic Actuated Valves,1" Stohr 1200 Pneumatic Actuated Valve, (3) 2" Stohr 1200 Check Valves,1" Stohr 1200 Check Valve, 2" Sulzer 2-Phase Mixer, Yokogawa RCCF31 Flow Meter, (2) 4" Pneumatic Actuated Valves, (2) 2" PneumaticActuated Valves

HEAT EXCHANGERS1 – STEELTEK 5,822 SQ. FT. VERTICAL CARBON STEEL SHELL AND TUBE

HEAT EXCHANGER (2009), 48" Dia. X 20', 280 PSI @ 550°F/-20°F Shell &Tubes. Insulated

2 – PERRY MODEL FTS-24-1740 1,740 SQ. FT. CARBON STEEL SHELL ANDTUBE HEAT EXCHANGERS, (Both 2008), 24" Dia. X 25', Shell & TubesMAWP 154/FV PSI @ 400°F, Shell & Tubes MDMT -20°F

2 – PERRY MODEL UTS-10-89 89 SQ. FT. HORIZONTAL CARBON STEELSHELL AND TUBE HEAT EXCHANGERS (Both 2008), 12" Dia. X 8', Shell &Tubes MAWP 200F/V PSI @ 400°F, Shell & Tubes MDMT -20°F, Insulated

1 – ARMSTRONG ENGINEERING TYPE A66-1250-82 PLATE HEAT EXCHANGER(2011), 18" X 60", Rated 150 PSI @ 230°F

9 – STEELTEK 304 STAINLESS STEEL SHELL AND TUBE HEAT EXCHANGERS,(To 2011), To 3151 Sq. Ft, Upt to 24” x 13’ Long, Up to MAWP Shell 350 PSI @150°F, Tube 318 PSI @ 150°F, MDMT Shell -55°F @ 350 PSI, Tubes -55°F @318 PSI

6 – ENERGY EXCHANGER CO. TYPE AKU 24/36-96 REBOILER HEATEXCHANGERS, (All 2011), MAWP Int., Shell 151 PSIG @ 490° F, Tube 177PSIG @ 520° F, MAWP Ext., Shell 15 PSIG @ 490° F, Tube 15 PSIG @ 520°F, MDMT, Shell -30° F @ 151 PSIG, Tube -30° F @ 177 PSI, Test 200 PSIG

OIL / FLUID HEATERS3 – CHROMALOX MODEL NWHSS-36-300P ELECTRIC THERMINOL FLUID

HEATERS, S/Ns 08210, 08209, 08211 (All 2011), Sheath & Shell 304 StainlessSteel, 480 Volt, 300,000 Watt

1 – HEAT RECOVERY CORP. MODEL 6VT-64-6HE-24-12-72 NATURAL GASFIRED HOT OIL HEATER (2009), Rated 89,200,000 BTU Per Hour, 35174 Sq.Ft Total Heating Surface, (8) John Zink B-601-1 Coolstar-18M Burners, 210 PSI@ 750°F. Stainless Steel Control Panel, Access Stairway w/ Catwalk, TestPressure 315 PSI

1 – CHROMALOX MODEL PFC-600B-80 HOT OIL SYSTEM, S/N PCO4993,80kw, 5 HP Pump, 80 GPM, 480 Volt

2009

Page 5: ONLINE AUCTION - Windows · PDF fileProduction Equipment from a 4000 Metric Ton Poly-Silicon Production Facility Online Bidding Opens: Friday ... GAS COMPRESSORS • HEAT EXCHANGERS

PRESSURE VESSELS • PUMPS • TANKS & DRUMS

For more information, please visit us on the web at www.hilcoind.com/Hoku 5

2011

20112009

2010

2011PRESSURE VESSELS4 – HARRIS THERMAL TRANSFER APPROXIMATELY 1,175 GALLON CARBON STEEL

SURGE DRUMS, (All 2011), 5' Dia. x 8' Straight Side, MAWP Int. 201 PSIG @ 250° F,MAWP Ext. 15 PSIG @ 200° F, MDMT -40° F @ Up to 200 PSIG, w/ Flanged Outlets

2 – HARRIS THERMAL TRANSFER STAINLESS STEEL PRESSURE VESSELS, (Both2011), MAWP Int. 157 PSI @ 150° F, MAWP Ext. 15 PSI @ 200° F, MDMT 130° F @ 150 PSI, Carbon Steel Skirt

PUMPS5 – BELL & GOSSETT MODEL 80SCBF10.75 30 HP INLINE PUMPS, Size 6x6x11, 980

GPM, HG-3 Suction Diffusers, (2) Expansion Tanks 7 – SIEGLE & EPPLE WATER PUMPING UNITS (All 2008), Skid Mounted, Cap. 105

c3/H, (2) Pumps, (1) Tranter Plate Type Heat Exchanger, (2) Hora Diaphragm Valves 3 – GOULD MODEL 4X6-9X 150 H.P. HOT OIL PUMPS, 1568 GPM, 460 Volt, 3575 Motor 15 – DURCO MODEL MK3 STD CENTRIFUGAL PUMPS, (5) 300 HP, Size,

3K10x8-16RV/15.19, 4000 Volt Motor, (4) 125 HP, Size 3K6x4-16RV/14.69, 460 Volt,(2) 7.5 HP, Size 1K1.5x1-62RV/6.13, (4) 10 HP, Size 1K1.5x1x82RV/5.81, SkidMounted w/ (20 API Basco Heat Exchangers

12 – TEIKOKU CANNED MOTOR PUMPS, (3) RV44-2811J4YM-1012U1V-A, 589 GPM,250' Head, Output 147.5 HP (110kw), (2) RV42-2515H4XM-0608TL1-E, 234 GPM,Head 151', Output 22kw, (2) RV42-2515H4XM-0608TL1-E, 216 GPM, 171 Head, 25kw,460 Volt, (2) RV43-2515H4XM-0608TL1-E, 156 GPM, Head 249', Output 42.9 HP(32kw), (1) RW42-2415J4XM-0506TL1-E, 98 GPM, Head 185', Output 15.5kw, (2) RW42-2245H4XM-02045L1-A, 5.3 GPM, Head 135', Output 74 HP (5.5kw)

6 – GOULD CENTRIFUGAL PUMPS, (3) Model HT3196 11.1 HP, Size 1.50x3-6 , (2) Model3196 150 HP, Size 4x6-17, 1716 GPM, 460 Volt, (1) Model 3195 7.5 HP, Size 1.50x3-6

7 – KEEN 56" DIA. X 158" PUMP BASINSCARBON & STAINLESS STEEL TANKS & DRUMS6 – HARRIS THERMAL TRANSFER ALCL3 REMOVAL DRUM

& TOWER VESSELS, (All 2011), MAWP Int. 118 PSIG @500° F, MAWP Ext. 15 PSIG @ 300° F, MDMT -30° F @ 100PSIG, Vessel Cap. 291 Gal., Tower 30" Dia. x 107"

1 – PACIFIC TANK 432,414 GALLON STORAGE TANK, S/N2011, 40' Dia. x 48' High, Material A516-60, Access Stairs ToTop, Insulated

1 – AMERICAN FABRICATION MODEL H 61,000 GALLON CARBON STEEL STORAGE TANK, S/N 10325-2 (2011), 14' Dia. x 48' 8" Straight Side, Rated 74 PSI/FV @ 300° F, MDMT-30° F @ 74 PSI, Insulated Mounted On Concrete Footings

4 – SUPERIOR STEEL PRODUCTS 60,000 GALLON EPOXYLINED VERTICAL CARBON STEEL STORAGE TANKS,(All 2010), 15' Dia. x 46' High, Designed Liquid Level 43'Designed Metal Temp -15 to 160° F

4 – SUPERIOR STEEL PRODUCTS 40,000 GALLON EPOXYLINED VERTICAL CARBON STEEL STORAGE TANKS,(All 2011), 14' Dia. x 35' High, Designed Liquid Level 32'Designed Metal Temp -15 to 160° F

2 – AMERICAN FABRICATION 38,000 GALLON CARBONSTEEL STORAGE TANKS, (Both 2010), 14' Dia. x 32'Straight Side, Rated 63 PSI/FV @ 300° F, MDMT -30° F @63 PSI, Insulated Mounted On Concrete Footings

1 – AMERICAN FABRICATION 32,000 GALLON CARBONSTEEL STORAGE TANK, S/N 10325-1 (2011), 12' Dia. x 38'Straight Side, Rated 82 PSI/FV @ 300° F, MDMT -30° F @ 82PSI, Insulated Mounted On Concrete Footings

1 – MIDWEST IMPERIAL STEEL FAB. 30,000 GALLON VER-TICAL CARBON STEEL SURGE DRUM (2010)

1 – 29,000 GALLON VERTICAL EMERGENCY VENT CAR-BON STEEL KNOCKOUT DRUM, 15' Dia. X 22' StraightSide, Rated For 650° F And 10 PSI, w/ Flanged Outlets

2 – AMERICAN FABRICATION 27,000 GALLON HORIZON-TAL CARBON STEEL STORAGE TANKS, (Both 2009), 12'Dia. x 36' Straight Side, Rated 74 PSI/FV @ 300° F, MDMT-30° F @ 74 PSI, Insulated Mounted On Concrete Footings

2 – SMITH MODEL F 15,000 GALLON VERTICAL CARBONSTEEL STORAGE TANKS (To 2011), 10' Dia.X 25' StraightSide, Rated 60 PSI @ 300°F. Inulated

1 – MIDWEST METAL ROLL & FAB. 15,000 GALLON VERTI-CAL CARBON STEEL STORAGE TANK (2010), Rated For100 PSI @ 600° F, Internal Access Ladder, Flanged Outlets

2 – HIGH COUNTRY FAB. 10,590 GALLON HORIZONTALCARBON STEEL RECEIVING TANKS, S/N 2566, 3241(Both 2011), 8' Dia. X 25' 6" Straight Side, MAWP FV/300PSI @ 100° F, MDMT -100° F @ FV/300 PSI

1 – AMERICAN FABRICATION MODEL F 7,500 GALLON VERTI-CAL CARBON STEEL STORAGE TANK, S/N 28454-5 (2009), 7' Dia. x 25' Straight Side, Rated 65 PSI/FV @ 300° F, MDMT -30°F @ 65 PSI, Insulated Mounted On Concrete Footings

LARGE QUANTITY OF Horizontal and Vertical Carbon Steel,Stainless Steel and Poly Tanks, Drums and Vessels, Up to 6’ x24’ and Up to 12,000 Gallon

Page 6: ONLINE AUCTION - Windows · PDF fileProduction Equipment from a 4000 Metric Ton Poly-Silicon Production Facility Online Bidding Opens: Friday ... GAS COMPRESSORS • HEAT EXCHANGERS

ADSORBERS/ABSORBERS • AIR HANDLING • AIR SCRUBBERS

To schedule an auction, please call Hilco Industrial  at 1-877-37-HILCO (44526)6

2008

20092010

ADSORBERS & ABSORBERS4 – KENNEDY 66 GALLON STAINLESS STEEL VERTICAL

ADSORBER TANKS (2011), 18" Dia. x 60", MAWP 150PSIG @ 275° F, MAWEP FV @ 275° F, MDMT -30° F @150 PSIG/FV

2 – ARROW STAINLESS STEEL ADSORBERS, (Both2009), MAWP Int. 174 PSI @ 240° F, MAWP Ext. FV @240° F, MDMT -30° F @ 174 PSI /FV, Approx. 2000Gal., 5' Dia. x 14' Long

6 – ARROW 6' X 30' VERTICAL CARBON STEELADSORBER TANKS, (2008), Vessel, MAWP Int. 279PSI @ 480° F, MAWP Ext. FV @ 480° F, MDMT -30° F@ 279/FV PSI, 24' Dia. Inner Chamber, MAWP Int. 460PSI @ 480° F, MAWP Ext. FV PSI @ 480° F, MDMT -30° F @ 460 PSI, Half Pipe Jacket, MAWP 340/FV PSI@ 480° F, MDMT -30° F @ 340/FV PSI

4 – KENNEDY APPROXIMATELY 340-GALLON STAINLESS STEEL ABSORBER PRESSURE VESSELS,MAWP Int. 150 PSI @ 225° F, MAWP Ext. FV, MDMT -30° F, Approx. 3' Dia. x 78", Carbon Media 30 lb. Per. CuFt., Mounted On Structure w/ Electrics And Plumbing

2 – CARBON STEEL ABSORPTION COLUMNS, w/ 36" x60" Fiberglass Carbone Acid Transfer Tank w/ (2) 5 HPCirculation Pumps, w/ Steel Structure

FACILITY SUPPORT EQUIPMENTAIR HANDLING4 – TRANE MODEL T-SERIES CLIMATE CHANGER AIR HANDLING UNITS, Model

TSCB100U0F00000000CC00A372.0, 75 HP Return Fan Module, Economizer Module, Cartridge/Bag FilterModule, Medium-Large Coil Module, Medium Blank Access Module, 100 HP Supply Fan Module, 460 Volt

4 – TRANE MODEL T-SERIES CLIMATE CHANGER AIR HANDLING UNITS, ModelTSCB030U0F00000000CC0A245.2, Air Mixing Module, Cartridge/Bag Filter Module, (3) Large CoilModules, 25 HP Supply Fan Module, 460 Volt

2 – CIRCUL-AIRE MODEL DAS-606-2D24/12SC AIR HANDLING UNITS, (Both 2009), 10 HP Blower, 460Volt

AIR SCRUBBERS1 – CROLL-REYNOLDS EMERGENCY WET SCRUBBER SYSTEM, 112,555 Gallon Holding Tank, Approx.

28' Dia. x 26' High, 96" Dia. Spray Tower, 42" x 42" Venturi Fume Scrubber, 30" Dia. Stack, CASE 1 (EMER-GENCY): 179,300 Lbs/Hr Trichlorosilane Gas @ 201 F & 1 PSIG For Max 10 Minutes, CASE 2 (VENTRELIEF): 18,840 Lbs/Hr Trichlorosilane Gas Max. Inlet Temp. 210 F For 30 Minutes CASE 3 (POWERLOSS): 4,616 Lb/Hr H2, 4,109 Lb/Hr HCL, 34,013 Lb/Hr Trichlorosilane, 75,217 Lb/Hr SICL4@ 392° F, 1PSIG For Max. 10 Seconds. All Three Cases Were Based On a Continuous N2 Flow Of 65 To 75 SCFMRemoval Efficiency Of 98% For The Trichlorsilane Was Scrubbing 20% NAOH, Re-Circulated RecirculationRates As Follows: Quench: 13 GPM @ 20 PSID AND 110 ° F (Max.) Spray Tower: 16,000 GPM @ 30 PSIDAND 110 ° F (Max.) (Min. 12,000 GPM) Jet Venturi: 3000 GPM @ 50 PSID AND 110 ° F (Max.), FiberglassConstruction, (Note: (5) 300 HP Pumps Being Sold Separate)

1 – VERANTIS WET GAS SCRUBBER SYSTEM (2010), w/ EVS-42 Educator, 84" Dia. X 20' Scrubber Vessel,2,500 Gallon Sump Tank, (2) 8" Basket Strainers, (2) 100 HP Goulds 10 x 8 -21 Pumps, (2) 15 HP InnomagPumps, (2) #CH-24 150 HP Blowers, Fiberglass Venting & Exhaust Pack, Stainless Steel Control Panel w/Allen Bradley PanelView Plus 1250 Control Interface, (4) Foxboro Communicators Series PH & ElectrodeConductivity, Constructed From Fiberglass Reinforced Plastic

1 – CEILCOTE WET GAS SCRUBBER SYSTEM (2009), w/ #EVS-10 Educator, 24" Spray Tower, #SPT-24-120 Scrubber Column, 48" Dia. Sump Tank, 36" Dia. Seal Pot, (2) 7.5 HP Investa Pumps, (2) 3 HP InnomagPumps, Constructed From Vinyl Ester Resin

Page 7: ONLINE AUCTION - Windows · PDF fileProduction Equipment from a 4000 Metric Ton Poly-Silicon Production Facility Online Bidding Opens: Friday ... GAS COMPRESSORS • HEAT EXCHANGERS

BOILERS • BRIDGE CRANES • CHILLERS • ELECTRICAL

For more information, please visit us on the web at www.hilcoind.com/Hoku 7

BOILERS2 – CLEAVER BROOKS MODEL FLX FLEXIBLE WATERTUBE STEAM BOILERS, S/Ns BT-04080-1-1

03913-1-1 (Both 2011), Natural Gas Fired, Fuel Input 2000 – 8000 / 2,500 – 10,000 MPH, Size 800 / 1000, FuelSeries 700, Pressure 150 ST / 160 HW, Model LNVG-80 C-B ProFire Burner

1 – CLEAVER BROOKS MODEL SSP7-260-2D SPRAYMASTER DEAERATOR SYSTEM, S/N 04080-2-1 (2011),7000 lb/hr, (2) Circulating Pumps

BRIDGE CRANES2 – ACECO 15-TON DOUBLE GIRDER, TOP RUNNING BRIDGE CRANES, 50' Span, Remote Controlled

CHILLERS2 – GEA FES 66.8-TON REFRIGERATION CHILLERS (Both 2011), Max Working Pressure 350 PSI, G Force

Touch Screen Control, #130S Compressor, 200 HP, 3575 RPM, 460 Volt Motor, (2) 3 HP Recirculating Pumps,Refrigerant R507 – R23, Skid Mounted

2 – GEA FES 34.6-TON REFRIGERATION CHILLERS (Both 2011), Max Working Pressure 350 PSI, G ForceTouch Screen Control, #130S Compressor, 200 HP, 3575 RPM, 460 Volt Motor, (2) 3 HP Recirculating Pumps,Refrigerant R507 – R23, Skid Mounted

2 – GEA FES HORIZONTAL CHILLER TANKS, w/ Top Mounted Heat Exchangers

ELECTRICAL4 – SWITCHGEAR POWER SYSTEMS, Harmonic Filter w/ Interrupter Switches,

Fuse Interrupting Symmetrical 63,000 AMP, Switch Type 1200 Amp ABBVersarupter, Max. Design Voltage 15kv, Nominal System Voltage 13.8/7.96kv480V, 3 Phase, 60hz, NEMA 3R Enclosure

1 – CUTLER-HAMMER 4-BANK MEDIUM VOLTAGE SWITCH GEAR, w/ (4)MVS Load Interrupter Switches, Max. Contious Operating Volts 15000, MainCross Bus Current Rating 800 Amp, Enclosure Type 3R, Uninstalled

1 – ABB METAL ENCLOSED INTERRUPTER SWITCH, S/N SWS8837001(2011), Rated Voltage 15 kv, BIL 95 kv, Main BUS 600 A, Frequency 60, ShortCircuit 40000 A, Fault Close 40000 A, Tag#480

1 – CATERPILLAR MODEL UPS 600 ROTARY UNINTERRUPTIBLE POWERSUPPLY, S/N CTX00313, Input 480 VAC 3 Phase, 60 Hz, 805 A Per Phase,Output 480 V 3 Phase, 722 A Per Phase, 600 kva Max., 480 kw Max.,Input/Output Cabinet S/N 1319, System Cabinet S/N 6336, (2) MMU CabinetsS/N 5021322 & 5021323

2 – RUSSELECTRIC MODEL RTBDNB-12004CEF AUTOMATIC TRANSFERSWITCHES, (Both 2008), Model 200 Auto Transfer Switch Control

3 – EATON MODEL 9390 UNINTERRUPTIBLE POWER SUPPLIES, IDCCabinet, Input 480 V, 3 Phase, 60 Hz, 160 A, Output 120/208 V, 3 Phase, 60Hz, 333 A, 108 kw, 120 kva, UPS Cabinet, Input 480 V, 3 Phase, 60 Hz, 160A, Output 480 V, 3 Phase, 60 Hz, 144 A, 108 kw, 120 kva, (2) Series 1085Battery Cabinets

1 – CATERPILLAR MODEL UPS 600 ROTARY UNINTERRUPTIBLE POWERSUPPLY, S/N CTX00319, Input 480 VAC 3 Phase, 60 Hz, 805 A Per Phase,Output 480 V 3 Phase, 722 A Per Phase, 600 kva Max., 480 kw Max.,Input/Output Cabinet S/N 1319, System Cabinet S/N 6336, (2) MMU CabinetsS/N 5021322 & 5021323

1 – SIEMENS 1200 AMP 2-BANK SWITCH GEAR, S/N 3003330344-000200,#WLL2F312 Breaker, (2) 800 Amp Breaker Switches, (1) 300 Amp BreakerSwitch

28 – ABB MODEL HVAC ACH550-01-038A-4+B055 DRIVES, w/ (4) ABBNOCH0030-65 DU/DT Filters

LARGE QUANTITY OF ELECTRICAL EQUIPMENT & SPARE PARTS,Including: Explosion Proof Electric Panels, Power Control Units, Breakers, PressPacks, Differential Relays, Cooper Blue Line Cable/Wire Trays, Skids of Tee's,Crosses & Elbows, Fuses, Spools of Wire

Register and Bid Online Only at

hilcoind.com/Hoku

Page 8: ONLINE AUCTION - Windows · PDF fileProduction Equipment from a 4000 Metric Ton Poly-Silicon Production Facility Online Bidding Opens: Friday ... GAS COMPRESSORS • HEAT EXCHANGERS

POWER SUPPLIES • PUMPING STATIONS • TRANSFORMERSWATER TREATMENT • FIRE SUPPRESSION, SAFETY & SUPPORT EQUIPMENT

To schedule an auction, please call Hilco Industrial  at 1-877-37-HILCO (44526)8

FIRE SUPPRESSION EQUIPMENT1 – FIRE SUPPRESSION PUMP SYSTEM, Aurora 8-491-18A

Centrifugal Pump, Powered By QSL9 365 HP Cummins DieselEngine, 3000 GPM / 125 PSI /1770 RPM, Aurora 8-491-18ACentrifugal Pump, Powered By 300 HP Electric Motor, 3000 GPM/ 125 PSI /1770 RPM, Metron Controls, Mounted On 12' x 35' 4" x11' 7" High Enclosed Skid

4 – FIRE SUPPRESSION VALVE BUILDINGS, with ReliableAutomatic Sprinkler Co. Low Pressure Dry Pipe Valves, ZurnWilkins 10" Backflow Preventer, 10" Gate Valves, NorsemanHeater, Controls

3 – AMEREX MODEL 334 100 LB CARBON DIOXIDE FIRE EXTINGUISHERS

QUANTITY OF HDPE Pond Liner & Fire Extinguishers

SAFETY EQUIPMENT Including Gas Monitors & Emergency Breathing Devices1 – HAWS SKID MOUNTED WATER TEMPERING SUPPLY

STATION, 480 Volt 1 – HAWS MODEL 8775-23-32-60 ENCLOSED WATER TEMPERING

SUPPLY STATION, 480 Volt

PLANT SUPPORT EQUIPMENTLARGE QUANTITY OF PALLET RACKING: Uprights 42" x 12' High,8' Cross Beams, Tear Drop Connections HUGE QUANTITY OF PLANT AND FACILITY SUPPORT EQUIPMENT,Including: Storage & Receiver Tanks, Pressure Vessels, Drums,Heaters, Blowers, Air & Hydrogen Filters, Test & Lab Equipment, PipeHangers & Insulation, Pallet Jacks, Cabinets, Carts, Power and HandTools, Fire Suppression Control & Electrical Parts Components & ControlBoxes & Electrical Connectors, Fans, Plumbing Valves & Parts, ConduitFittings & Fasteners, Computers & Office Equipment, Light Fixtures, Etc.

POWER SUPPLIES23 – AEG MODEL THYROBOX VSC POWER SUPPLIES, Nominal Voltage 0-1700,

Nominal Current 0-3200 A, Aux. Voltage 3x 230/400 11 – ABB THYRISTOR POWER SUPPLIES, Main Power 3 Phase 13800 V, 60 hz,

System Rating 0-690 VAC, 0-1200 A Cooling Forced Air

PUMPING STATIONS8 – PUMPING STATIONS, Various Configurations: Up to (4) Nikisso Canned Motor

Pumps, and Up to (20) Pneumatic Actuated Valves1 – CARBIS LOADING/UNLOADING STATION, Including, Platform w/ 2" Dia.

Boom, Enraf Contrec 414 Batch Controller, (2) Rosedale #8530-2F-2-150-STW22C Canister Filters

TRANSFORMERS22 – HUNTERDON 3100 KVA DRY TYPE TRANSFORMERS, Class AA, High

Voltage 14400, Low Voltage 1800Y/210

WATER TREATMENT1 – DIGITAL ANALYSIS MODEL LT100 PH ADJUSTMENT SYSTEM, Allen

Bradley PanelView Plus 400 Control Interface, 1700 Gallon Treatment Tank, (2)65 Gallon Day Tanks, (1) 360 Gallon Effluent Tank, Diaphragm Pump

1 – AQUAFINE MODEL HX04CDLU ULTRAVIOLET DISINFECTION UNIT, S/NCND 12/2010 009 (2010), Skidded w/ Ultraviolet Tube w/ (2) Stainless SteelCartridge Filters, 2nd Skid w/ (3) Stainless Steel Cartridge, Design Pressure 150PSIG, 240 Volt, 94% UVT: 251 GPM Flow Rate, 99% UVT: 300 GPM

1 – GE WATER DEIONIZATION DISTRIBUTION SYSTEM (2010), (2) 30 HPGrundfos Stainless Steel Pumps, 10,574 Gallon Fiberglass Storage Tank, 460Volt, DI Flow 150 GPM DI Pressure 65 PSIG after Final Filters Temperature 71Fnominal (+ tbdF) Resistivity >18.1 Meg/cm @ 25C TOC On-Line

1 – DIGITAL ANALYSIS SILICA REDUCTION SYSTEM, Allen Bradley PanelViewPlus 400 Control Interface, (3) 100 Gallon Tanks, (1) 105 Gallon FiltratreCollection Tank, (2) Diaphragm Pumps

Page 9: ONLINE AUCTION - Windows · PDF fileProduction Equipment from a 4000 Metric Ton Poly-Silicon Production Facility Online Bidding Opens: Friday ... GAS COMPRESSORS • HEAT EXCHANGERS

HILCO Industrial is a division of Hilco Global • Headquarters 5 Revere Drive, Ste. 206 • Northbrook, IL 60062 • All rights reserved

Printed in USA • HOK3965 • IL  License #444.000215 • Please visit our website at www.hilcoind.com to review our complete terms and conditions.

FollowUs on:

A Hilco Global Company

Vested in Your Success

OVER 35 OFFICES THROUGHOUT NORTH, CENTRAL & SOUTH AMERICA, EUROPE, MIDDLE EAST, ASIA, AUSTRALIA

HilcoTM Industrial ONLINE AUCTIONTerms of Sale

An 18% buyer's premium will be charged on all assets.The buyer’s premium will be reduced to 16% for paymentsmade by means of cash, cashier’s check, company check(with bank letter of guarantee) or wire transfer within 48hours of sale close. Everything will be sold online to thehighest bidder for cash, in accordance with theAuctioneer’s customary “Terms of Sale”, copies of whichwill be posted online. All items will be sold “as is, where-is” without any warranties, expressed or implied. Althoughobtained from sources deemed reliable, the Auctioneermakes no warranty or guarantee to the accuracy of theinformation herein contained. Bidders are encouraged tothoroughly inspect the items on which they intend to bidprior to sale. Absolutely no items will be removed until theday after the conclusion of the sale and payment is madein full. Subject to additions, deletions and prior sale. Forupdated information, please visit our website atwww.hilcoind.com for any date, sale process, terms andconditions and list of available assets.

Payment: INVOICES WILL BE EMAILED WITHIN 24 HOURSAFTER THE AUCTION CLOSES. Payment is to be made toHilco Industrial, LLC. Payment Options: VISA, MastercardDiscover accepted – if invoice total is $2,000 or less; WireTransfer; Certified Check; or Company Check (with Bank let-ter of guarantee – see sample letter below). All sales are sub-ject to sales tax. Purchasers claiming exemptions from taxesmust provide proof satisfactory to the Auctioneer of their enti-tlement to claim such exemptions. Please see complete termsand conditions on our website, www.hilcoind.com.

Sample Bank Letter(Bank Name) unconditionally guarantees payment to Hilco Industrial from (Company Name). This guarantee will be valid for purchases made at theAuction of Hoku Materials, Inc. #3 on October 30-November 4, 2015.

Electrical Equipment, Chemical ProcessEquipment, Industrial Supply & Polysilicon

Production Equipmentfrom a

4000 Metric Ton Poly-Silicon Production Facility

Online Bidding Opens: Friday, October 30th

Online Bidding Closes: Wednesday, November 4TH

Pocatello, Idaho

3rd SALE IN A SERIES OF AUCTIONS