Online Calibration of the D0 Vertex Detector. Initialization Procedure and Database Usage. Harald Fox D0 Experiment Northwestern University. Online Calibration of the D0 Vertex Detector. What is Online Calibration? Determination of: Threshold for zero-suppression of the read out. - PowerPoint PPT Presentation

Citation preview

Page 1: Online Calibration of the  D0 Vertex Detector

Online Calibration of the D0 Vertex Detector

Initialization Procedure and Database Usage

Harald FoxD0 Experiment

Northwestern University

Page 2: Online Calibration of the  D0 Vertex Detector

Online Calibration of theD0 Vertex Detector

What is Online Calibration?

Determination of:– Threshold for zero-suppression of the read out.– Pedestals and gains for the Level 3 Trigger and the

Prompt Reconstruction.

Page 3: Online Calibration of the  D0 Vertex Detector

When and Where?

• When?– Special calibration run between 2 machine

fillings.– The time window for calibration is negotiable

between D0, CDF, and the accelerator.– The Secondary Data Acquisition (SDAQ) is

foreseen for this task.

Page 4: Online Calibration of the  D0 Vertex Detector

When and Where?

• Where?– The calibration process runs on the front end

processor of each readout crate.– Data is transferred to the CPU instead of the

Level 3 Trigger.– Pedestals and gains are calculated locally and

stored in the database.– New threshold values are calculated from

pedestals.

Page 5: Online Calibration of the  D0 Vertex Detector

What?

• The D0 Silicon Tracker consists of 6 barrels, 12 F-disks, and 8 H-disks 800,000 channels.

• Commissioning and testing requires read out of a complete barrel (432 SVX, 55300 channels).

• Each SVX read out chip has its own parameters.

Database GUI Manipulation Monitoring

Page 6: Online Calibration of the  D0 Vertex Detector

Calibration Steps

A. Start a calibration run (Taker/COOR).

B. Initialization of the electronics (“download”).

– The initialization is part of COMICS.

– An ORACLE database is used to store:• Download Parameters• History of time

dependent informationJune, 2000 T. Yasuda, Fermilab

Taker

COOR

COMICS

CratesCrates

CalibrationManager

CalibrationDatabase

Calib. DataProcessor

DatabaseInterface

Configure

Request start run

Request download

Download Start run

End run

Data

PedestalsGains

PedestalsGains

ComparisonResults

DatabaseAccess

End calib.

Start run, End run

Online CalibrationOnline CalibrationSystemSystem

Validator

Calib ManagerGUI

Page 7: Online Calibration of the  D0 Vertex Detector

Calibration Steps (cont.)

C. Determine pedestals and gains (Huaming Wang).

– 5 Calibration voltages.– Pedestals and gains

Calibration Manager.

D. The Validator checks errors and consistency.

June, 2000 T. Yasuda, Fermilab

Taker

COOR

COMICS

CratesCrates

CalibrationManager

CalibrationDatabase

Calib. DataProcessor

DatabaseInterface

Configure

Request start run

Request download

Download Start run

End run

Data

PedestalsGains

PedestalsGains

ComparisonResults

DatabaseAccess

End calib.

Start run, End run

Online CalibrationOnline CalibrationSystemSystem

Validator

Calib ManagerGUI

Page 8: Online Calibration of the  D0 Vertex Detector

Calibration Steps (cont.)

E. Calibration data Calibration Database.

F. New thresholds are calculated.

– Used for next initialization.

June, 2000 T. Yasuda, Fermilab

Taker

COOR

COMICS

CratesCrates

CalibrationManager

CalibrationDatabase

Calib. DataProcessor

DatabaseInterface

Configure

Request start run

Request download

Download Start run

End run

Data

PedestalsGains

PedestalsGains

ComparisonResults

DatabaseAccess

End calib.

Start run, End run

Online CalibrationOnline CalibrationSystemSystem

Validator

Calib ManagerGUI

Page 9: Online Calibration of the  D0 Vertex Detector
Page 10: Online Calibration of the  D0 Vertex Detector

Design of theElectronics Database

• The hardware is mirrored:– Crates, modules, module

channels, and silicon detectors.– Multiple to multiple connections

between modules are allowed.• Download parameters are

stored.• The path from a VME Readout

Board (VRB) to a silicon detector (HDI) is traceable.

• A history of all modifications is kept.

Page 11: Online Calibration of the  D0 Vertex Detector

The Initialization Process

• The initialization is integrated in the online environment (COMICS).

• A Python (OO-scripting language) program is used for downloading.

• The program is partitioned into 3 layers:1. Hardware layer:

• Knows about module and register addresses.• Communication via EPICS.

Page 12: Online Calibration of the  D0 Vertex Detector

The Initialization Process (Program Layers)

2. The database layer:• The hardware configuration is determined in a

database lookup.• Download parameters are extracted.

3. GUI for expert interaction:• Allows modification of the database.• Manipulation of each hardware module.• Status display.

Page 13: Online Calibration of the  D0 Vertex Detector

Database Layer

• Each hardware module and database table is represented by an object.

• The database is accessed via an interface design pattern.

• This allows an optimization of the database access.

• The electronics configuration is determined on a crate to crate basis.

• Each module is initialized in the proper sequence.

Page 14: Online Calibration of the  D0 Vertex Detector

GUI Layer

• The GUI is an interaction tool for the experts. It replaces a PC based support tool.

• It gives an overview for each crate allowing basic operations.

Used for the barrel read out right now.

Page 15: Online Calibration of the  D0 Vertex Detector

GUI Layer (cont.)

Page 16: Online Calibration of the  D0 Vertex Detector

GUI Layer (cont.)

• A detailed view allows interaction with all hardware modules. This allows the initialization of single modules or module chains.

• Allows modification of the database:– Enable/disable of modules for the subsequent download.– Change of hardware configuration (re-cabling).– Change of initialization parameters.– Calculation of new thresholds.

Page 17: Online Calibration of the  D0 Vertex Detector

Use Cases

Three test stands are available:

Northwestern 1% (SiDet) 10% (SiDet)Complete Barrel

2 HDI 2 HDI 7 (72) HDI

2 VRB 1 VRB 5 (9) VRB

768 Channel 2304 Channel 4992 (55296) Channel

Page 18: Online Calibration of the  D0 Vertex Detector

Milestone Goal Achieved!

• We successfully demonstrated the Online Calibration at the 10% test stand!

• The Silicon Tracker is the first detector using the complete Online Calibration System!

• Pedestals and gains were calculated and stored in the Online Database.

• Data was send to the Level 3 Trigger and saved to disk. SMT examine was used to monitor the data taking process.

Page 19: Online Calibration of the  D0 Vertex Detector

Conclusion

• The D0 Silicon Tracker requires online calibration. Demanding task with 800,000 channels!

• We developed database and GUI tools necessary to meet the challenge.

• We developed the program running on the Front End Processor determining pedestals and gains.

• These tools were successfully tested in the D0 Online Calibration Framework.

We are leading the development.

Page 20: Online Calibration of the  D0 Vertex Detector

Hardware Configuration

• VRB: VME Read Out Board

• SEQ: SVX Sequencer

Silicon Read-Out Data Flow

platformplatform

SEQ

SEQ

SEQ

SEQ

SEQ

SEQ

VRB Controller

Optical Link1Gb/s

3/6/8/9 Chip HDI

Sensor

V

B

D

V

R

B

V

R

B

V

R

B

V

R

B

68k Bit3

PC

Silicon Graphics

L3MPM

VME

Low Mass 3M

1553

NRZ / CLK

HV / LV

Page 21: Online Calibration of the  D0 Vertex Detector

Hardware Configuration

• VRB: VME Read Out Board

• SEQ: SVX Sequencer

Silicon Read-Out Data Flow

platformplatform

SEQ

SEQ

SEQ

SEQ

SEQ

SEQ

VRB Controller

Optical Link1Gb/s

3/6/8/9 Chip HDI

Sensor

V

B

D

V

R

B

V

R

B

V

R

B

V

R

B

68k Bit3

PC

Silicon Graphics

L3MPM

VME

Low Mass 3M

1553

NRZ / CLK

HV / LV

Page 22: Online Calibration of the  D0 Vertex Detector