Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
Online Monitoring of GSHP SystemsBenedikt
26-09-2012
Andre Quintino Duarte
Summary1. DAQ - Data Acquisition System1.1. Hardware Installation
1.1.1. Power Connections1.1.2. Communication Connections1.1.3. Sensors Connections
1.2. Software1.2.1. Software Configuration1.2.2. Measuring Utility
1.3. Further Development in Coimbra
2. Server2.1. System Overview2.2. DMS Input
2.3. Access Levels2.3.1. Free Access2.3.2. Partial Access2.3.3. Full Access
4. Web Interface
1. DAQ - Data Acquisition System
National Instruments cRIO 9074
1. DAQ - Data Acquisition System
National Instruments cRIO 9074
NI 9217NI 9219
NI 9871
1. DAQ - Data Acquisition System
DAQDAQ
1. DAQ - Data Acquisition System
DAQDAQ
Brunata Thermal Meters
PyranometerIndoor/Outdoor
Temperature Sensors
Humidity Sensor
Carlo Gavazzi Meters
1. DAQ - Data Acquisition System
D A Q
D A Q
DAQSystem
DAQSystem
1. DAQ - Data Acquisition SystemSeptemes les
Vallons,France
DAQSystem
DAQSystemDAQ
SystemDAQ
SystemDAQ
SystemDAQ
SystemDAQ
SystemDAQ
SystemDAQ
SystemDAQ
SystemDAQ
SystemDAQ
SystemDAQ
SystemDAQ
SystemDAQ
SystemDAQ
System
Oradea, Romenia
Coimbra, Portugal
Benedikt, Slovenia
Valencia, Spain
Barcelona, Spain
Padova,Italy
Athens,Greece
InternetInternet
InternetInternet
InternetInternet
InternetInternet
InternetInternet
InternetInternet
InternetInternet
InternetInternet
Ground Med
WebSit e
Ground Med
WebSit e
DMSServer
1. DAQ - Data Acquisition SystemDAQ
SystemDAQ
System
- Make all measurements every 15 seconds;- After 4 measurements (1 minute) a sting of Data is created;
Time 0 sec: var1; var2; var3; ...; var59Time 15 sec: var1; var2; var3; ...; var59Time 30 sec: var1; var2; var3; ...; var59Time 45 sec: var1; var2; var3; ...; var59
1. DAQ - Data Acquisition System
average var1; average var2; average var3; ...; average var59
DAQSystem
DAQSystem
- Every 10 minutes, DAQ updates Data into DMS server;
1. DAQ - Data Acquisition System
average var1; average var2; average var3; ...; average var59
DAQSystem
DAQSystem
average var1; average var2; average var3; ...; average var59average var1; average var2; average var3; ...; average var59average var1; average var2; average var3; ...; average var59average var1; average var2; average var3; ...; average var59average var1; average var2; average var3; ...; average var59average var1; average var2; average var3; ...; average var59average var1; average var2; average var3; ...; average var59average var1; average var2; average var3; ...; average var59average var1; average var2; average var3; ...; average var59
1. DAQ - Data Acquisition SystemDAQ
SystemDAQ
System
10 MinuteData
1. DAQ - Data Acquisition System
DAQSystem
DAQSystem
DMSServer
10 MinuteData
1. DAQ - Data Acquisition System
DAQSystem
DAQSystem
10 MinuteData
DMSServer
1. DAQ - Data Acquisition System
DAQSystem
DAQSystem
10 MinuteData
DMSServer
1. DAQ - Data Acquisition System
DAQSystem
DAQSystem
Data Buffer
No Data Loss
10 MinuteData
n x
DMSServer
1. DAQ - Data Acquisition System
DAQSystem
DAQSystem
DMSServer
10 MinuteData
n x
1.2. Software Installation1.2.1. Software Configuration
- 8 different demonstration sites
Does this means 8 different software versions?
1.2. Software Installation1.2.1. Software Configuration
1.2. Software Installation1.2.2. Measuring Utility
1.2. Software Installation1.2.2. Measuring Utility
1.3. Further Development in Coimbra
NI 9472
- 8 Sourcing Digital Outputs;- 6 to 30V range.
Finder Relay20.21.9.024.4000
- 24V Coil Voltage;- 250V AC Rated Voltag
1.3. Further Development in Coimbra
2. Server
HP DL120 G7 Rack Data Server
- Intel Xeon 4-core processor;- Multiple Hard Disk Drives;- RAID 5 (Speed + Data Protection);- Modular Server.
2. Server
Data Base storage;
Web Interface storage;
Excel file
2.1. System OverviewSeptemes les
Vallons,France
DAQSystem
DAQSystemDAQ
SystemDAQ
SystemDAQ
SystemDAQ
SystemDAQ
SystemDAQ
SystemDAQ
SystemDAQ
SystemDAQ
SystemDAQ
SystemDAQ
SystemDAQ
SystemDAQ
SystemDAQ
System
Oradea, Romenia
Coimbra, Portugal
Benedikt, Slovenia
Valencia, Spain
Barcelona, Spain
Padova,Italy
Athens,Greece
InternetInternet
InternetInternet
InternetInternet
InternetInternet
InternetInternet
InternetInternet
InternetInternet
InternetInternet
DMSServer
2.2. DMS Input
PHP Script
GroundMedDataBase
ServerInternet
10 MinuteData
PHP Script
GroundMedDataBase
ServerInternet
10 MinuteData
2.2. DMS Input
Ground Med
WebSit e
Ground Med
WebSit e
2.3. Access Levels
Free Access
Partial Access
Total Access
(Everyone can access to thereal time web display, table view and graphical view)
(Gound-Med partners access to the Excel file with all variables except the heat pump confidential information)
(Full access to Excel files. ISR only)
GroundMedDataBase
+
Free Access- No Login is required;- Everyone can access to the real time web display;- Visible variables only;- Access to everyone.
2.3. Access Levels2.3.1 Free Access
2.3. Access Levels2.3.2 Partial Access
- Login is required (one for all pilot);- Real time web display with all allowed variable;- No access to CIAT Heat Pump variables;- Excel file available for download;- Option between “Daily Values” or “Summary” files.
2.3. Access Levels2.3.3 Full Access
- Login is required (one for each pilot);- Real time web display with all variable;- Full access to CIAT Heat Pump variables;- Excel file available for download;- Option between “Daily Values” or “Summary” files.
3. DMS Status
2. Web Site (http://groundmed.isr.uc.pt)2.1. Free Access2.2. Partial Access2.3. Full Access
1. Data Server1.1. Input data from all GroundMed Pilots
(table view only)
4. Web Interface
4. Web Interface
Options after login:
4. Web Interface
4. Web InterfaceFree
Access, Coimbra
Thank You
Andre Quintino Duarte