WAITE PARK ELEMENTARY ADDENDUM NO. 1 OP #20-2924 3/20/2020 SAFE/SECURE ENTRANCE PROJECT 1 OP #20-2924 ADDENDUM No. 1 (ONE) Project: Waite Park Elementary Owner: Minneapolis Board of Education Improvements and Renewal Davis Center 1800 34 th Ave NE 1250 W Broadway Ave Minneapolis, MN 55418 Minneapolis, MN 55411 Architect: 292 Design Group Structural Engineer: 3533 East Lake Street Ericksen Roed & Associates Minneapolis, MN 55406 2550 University Ave W Suite 423-5 St. Paul, MN 55114 Mechanical/Electrical Engineer: Security Consultant: Hallberg Engineering True North Consulting Group 1750 Commerce Court 140 3 rd Street South White Bear Lake, MN 55110 Stillwater, MN 55082 Civil Engineer/Landscape Architect: Hansen Thorp Pellinen Olson (HTPO, Inc) 7510 Market Place Drive, Suite 500 Eden Prairie, MN 55344 Date: March 20, 2020 Architect’s Project Number: 19038.00 Number of Pages: 7 pages (8 ½” x 11”) 4 re-issued drawing sheets (30” x 42”) This Addendum forms a part of the Contract Documents and modifies the original Bidding Documents dated March 12 th , 2020. Portions of the Bidding and Contract Documents not altered by this addendum remain in full force. Acknowledge receipt of this addendum in the space provided on the Bid Form. Failure to do so may subject the Bidder to disqualification. CHANGES TO PROJECT MANUAL Section 00 11 13 – Call for Bids 1. Add the attached copy of the sign in sheet for the General Contractor Mandatory Pre-Bid Conference held on March 17 th , 2020 Section 10 14 01 – Digital Monument Signs 1. Reissued in its entirety. CHANGES TO DRAWINGS All Architectural Sheets (G-001 through A-900)

OP #20-2924 ADDENDUM No. 1 (ONE)...WAITE PARK ELEMENTARY ADDENDUM NO. 1 OP #20-2924 3/20/2020 SAFE/SECURE ENTRANCE PROJECT 2 1. Revise project title in each sheet’s titleblock to

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: OP #20-2924 ADDENDUM No. 1 (ONE)...WAITE PARK ELEMENTARY ADDENDUM NO. 1 OP #20-2924 3/20/2020 SAFE/SECURE ENTRANCE PROJECT 2 1. Revise project title in each sheet’s titleblock to

WAITE PARK ELEMENTARY ADDENDUM NO. 1 OP #20-2924 3/20/2020 SAFE/SECURE ENTRANCE PROJECT 1

OP #20-2924

ADDENDUM No. 1 (ONE)

Project: Waite Park Elementary Owner: Minneapolis Board of Education Improvements and Renewal Davis Center 1800 34th Ave NE 1250 W Broadway Ave Minneapolis, MN 55418 Minneapolis, MN 55411

Architect: 292 Design Group Structural Engineer: 3533 East Lake Street Ericksen Roed & Associates Minneapolis, MN 55406 2550 University Ave W 

Suite 423-5 St. Paul, MN 55114

Mechanical/Electrical Engineer: Security Consultant: Hallberg Engineering True North Consulting Group 1750 Commerce Court 140 3rd Street South White Bear Lake, MN 55110 Stillwater, MN 55082

Civil Engineer/Landscape Architect: Hansen Thorp Pellinen Olson (HTPO, Inc)7510 Market Place Drive, Suite 500 Eden Prairie, MN 55344

Date: March 20, 2020 Architect’s Project Number: 19038.00

Number of Pages: 7 pages (8 ½” x 11”) 4 re-issued drawing sheets (30” x 42”)

This Addendum forms a part of the Contract Documents and modifies the original Bidding Documents dated March 12th, 2020. Portions of the Bidding and Contract Documents not altered by this addendum remain in full force.

Acknowledge receipt of this addendum in the space provided on the Bid Form. Failure to do so may subject the Bidder to disqualification.

CHANGES TO PROJECT MANUAL

Section 00 11 13 – Call for Bids 1. Add the attached copy of the sign in sheet for the General Contractor Mandatory Pre-Bid

Conference held on March 17th, 2020

Section 10 14 01 – Digital Monument Signs 1. Reissued in its entirety.

CHANGES TO DRAWINGS

All Architectural Sheets (G-001 through A-900)

Page 2: OP #20-2924 ADDENDUM No. 1 (ONE)...WAITE PARK ELEMENTARY ADDENDUM NO. 1 OP #20-2924 3/20/2020 SAFE/SECURE ENTRANCE PROJECT 2 1. Revise project title in each sheet’s titleblock to

WAITE PARK ELEMENTARY ADDENDUM NO. 1 OP #20-2924 3/20/2020 SAFE/SECURE ENTRANCE PROJECT 2

1. Revise project title in each sheet’s titleblock to read “WAITE PARK ELEMENTARY OP#20-2924 SAFE/SECURE ENTRANCE PROJECT”. These sheets have not been reissued for this change unless listed below.

Sheet A-011 – SITE PLAN & OVERALL PLAN – FIRST FLOOR

1. F2/A-011 “SIGNAGE DETAIL @ MONUMENT SIGN” Added overall height dimension to metal sign panel.

Sheet AD101 – GROUND FLOOR DEMO PLANS

1. A1/AD101 – Demo Ground Floor Areas ‘B’ & ‘C’ Added dimensions to clarify extents of elevator & elevator shaft demolition.

Sheet AD111 – FIRST FLOOR DEMO PLANS

1. A3/AD111 “Demo First Floor Area ‘B’” Added dimensions to clarify extents of elevator & elevator shaft demolition.

Sheet AD113 – FIRST FLOOR DEMO PLANS

1. A2/AD113 “Demo First Floor Area ‘D’” Added dimensions to clarify extents of elevator & elevator shaft demolition.

Addendum No. 1 continues with the following attachments: Spec Sections

Pre-Bid Sign In Sheet 10 14 01 – Digital Monument Signs

Drawings A-011 – Site Plan & Overall Plan – First Floor

AD101 – Ground Floor Demo Plans AD111 – First Floor Demo Plans AD113 – First Floor Demo Plans

Page 3: OP #20-2924 ADDENDUM No. 1 (ONE)...WAITE PARK ELEMENTARY ADDENDUM NO. 1 OP #20-2924 3/20/2020 SAFE/SECURE ENTRANCE PROJECT 2 1. Revise project title in each sheet’s titleblock to
Page 4: OP #20-2924 ADDENDUM No. 1 (ONE)...WAITE PARK ELEMENTARY ADDENDUM NO. 1 OP #20-2924 3/20/2020 SAFE/SECURE ENTRANCE PROJECT 2 1. Revise project title in each sheet’s titleblock to

WAITE PARK ELEMENTARY SAFE/SECURE ENTRANCE PROJECT OP#20-2924

10 14 01 - 1 DIGITAL MONUMENT SIGNS Reissued Section

Addendum #01

SECTION 10 14 01 DIGITAL MONUMENT SIGNS (ALTERNATE)

PART 1 GENERAL 1.01 SECTION INCLUDES

A. Building identification signs – Engraved panel with outdoor programmable LED. 1.02 RELATED REQUIREMENTS

A. Division 26 - Electrical Systems. B. Division 28 – Telecommunications Systems.

1.03 SUBMITTALS A. See Section 01 33 00 for submittal procedures. B. Product Data: Manufacturer's printed product literature for each type of sign, indicating sign

styles, font, foreground and background colors, locations, overall dimensions of each sign. C. Provide manufacturer's data sheets on panelized LED display systems including

recommendations for preparation, storage and handling, and installation. D. Shop Drawings: Layout and construction of sign cabinet and LED panel display. Indicate cable

routing, connections between equipment, anchor and support details, and adjacent construction.

E. Manufacturer's Installation Instructions: Include installation templates and attachment devices. F. Selection Samples: Where colors are not specified, submit two sets of color selection charts or

chips. G. Verification Samples: Submit samples showing colors specified. H. Manufacturer's Certificates: Certify products meet or exceed specified requirements. I. Project Record Documents: Provide quantities, type, and location for components, cabling and

accessories. J. System Setting Backup: Provide an electronic file of all system settings. K. Security Items:

1. Provide passwords to access control functions for hardware and software user interfaces. L. Warranty: Sample warranty.

1.04 QUALITY ASSURANCE A. Manufacturer Qualifications: Company specializing in manufacturing products specified in this

section, with not less than three years of documented experience. B. Authorized Manufacturer Representative: System shall be configured and commissioned by an

authorized manufacturer representative. C. Installer Qualifications: Company specializing in performing the work of this section with

minimum three years of experience. 1.05 DELIVERY, STORAGE, AND HANDLING

A. Deliver and store products in compliance with manufacturer instructions. B. Package signs as required to prevent damage before installation.

1.06 WARRANTY A. Manufacturer's Warranty: Manufacturer agrees to repair or replace components of product that

fail(s) in materials or workmanship within specified warranty period. 1. Warranty Period: five year(s) from date of Substantial Completion.

Page 5: OP #20-2924 ADDENDUM No. 1 (ONE)...WAITE PARK ELEMENTARY ADDENDUM NO. 1 OP #20-2924 3/20/2020 SAFE/SECURE ENTRANCE PROJECT 2 1. Revise project title in each sheet’s titleblock to

WAITE PARK ELEMENTARY SAFE/SECURE ENTRANCE PROJECT OP#20-2924

10 14 01 - 2 DIGITAL MONUMENT SIGNS Reissued Section

Addendum #01

PART 2 PRODUCTS 2.01 MANUFACTURERS

A. Provide products from manufacturers listed below. B. Substitutions: See Section 00 21 13.

2.02 ENGRAVED PANEL SIGNAGE A. Basis of Design Product

1. Manufacturer: Signation Sign Group, 6840 Shingle Creek Parkway, Brooklyn Center, MN 55430.

2. Model: Custom sign panel 3. Description: Water jet engraved aluminum panel sign. 4. Size: As indicated on the drawings. 5. Material: 1/4-inch thick aluminum plate. 6. Copy:

a. Text: as indicated on the drawings. b. Graphics: provide color graphics. Graphic logos provided by Owner.

7. Finish: Baked Enamel or Powder Coat. a. AAMA 2603 except with a minimum dry film thickness of 1.5 mils (0.04 mm). b. Color and Gloss: As selected by the Architect from manufacturer’s full range.

8. Mounting: Concealed studs with back face of panel flush with masonry. 2.03 EXTERIOR PROGRAMMABLE LED SIGN

A. Manufacturer: Subject to compliance with requirements, provide products by the following: 1. Manufacturer: Think Digital Signs, 7760 France Avenue South, Edina, MN 55435. 2. Equivalent Product from Electro-Matic Visual Inc., Farmington Hills, MI 48335.

B. Basis of Design Product: 1. Model: Watchfire Message Center. 2. Description: Exterior LED digital color message sign. 3. Size: Nominal 24” x 48” display. Refer to Drawings for layout and overall signage

dimensions. 4. Power: As indicated on the Drawings. 5. Controls: Single mode modular. 6. Communication: Provide fiber optic cable for connection to the building, cable installation

by electrical contractor. 7. Product construction:

a. Cabinet: Galvanized steel b. Sign panel: fabricated from 12-inch by 12-inch LED modules c. Graphics Color: Monochrome. d. Provide waterproof construction.

C. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application.

D. Thermal Movements: Allow for thermal movements from ambient and surface temperature changes.

E. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

Page 6: OP #20-2924 ADDENDUM No. 1 (ONE)...WAITE PARK ELEMENTARY ADDENDUM NO. 1 OP #20-2924 3/20/2020 SAFE/SECURE ENTRANCE PROJECT 2 1. Revise project title in each sheet’s titleblock to

WAITE PARK ELEMENTARY SAFE/SECURE ENTRANCE PROJECT OP#20-2924

10 14 01 - 3 DIGITAL MONUMENT SIGNS Reissued Section

Addendum #01

F. Controls 1. Provide manufacturer’s standard sign controls with connection to Owner’s Ethernet.

PART 3 EXECUTION 3.01 EXAMINATION

A. Verify that substrates and support structure is in place and properly prepared. B. Verify that required power and data sources are provided. C. Verify that space is available for centrally located components. D. Notify Architect of unsatisfactory preparation before proceeding.

3.02 PREPARATION A. Prepare substrates using the methods recommended by the manufacturer for achieving the

best result under the project conditions. B. Do not proceed with installation until support structure and substrates have been prepared

using the methods recommended by the manufacturer and deviations from manufacturer's recommended tolerances are corrected. Commencement of installation constitutes acceptance of conditions.

3.03 INSTALLATION A. Install in accordance with manufacturer's instructions . B. Install message center and signs level and plumb with fasteners recommended by the

manufacturer. C. Custom Mounting: Coordinate with support structure as indicated on drawings for mounting

and support. D. Record any necessary changes to the system design.

3.04 CLOSEOUT ACTIVITIES A. See Section 01 77 00 - Closeout Procedures, for closeout submittals. B. See Section 01 78 27 – Operating and Maintenance Data, for additional requirements. C. Demonstrate proper operation and maintenance of equipment to Owner's designated

representative. 3.05 PROTECTION

A. Protect installed products from subsequent construction operations.

END OF SECTION

Page 7: OP #20-2924 ADDENDUM No. 1 (ONE)...WAITE PARK ELEMENTARY ADDENDUM NO. 1 OP #20-2924 3/20/2020 SAFE/SECURE ENTRANCE PROJECT 2 1. Revise project title in each sheet’s titleblock to

WAITE PARK ELEMENTARY SAFE/SECURE ENTRANCE PROJECT OP#20-2924

10 14 01 - 4 DIGITAL MONUMENT SIGNS Reissued Section

Addendum #01

THIS PAGE LEFT INTENTIONALLY BLANK

Page 8: OP #20-2924 ADDENDUM No. 1 (ONE)...WAITE PARK ELEMENTARY ADDENDUM NO. 1 OP #20-2924 3/20/2020 SAFE/SECURE ENTRANCE PROJECT 2 1. Revise project title in each sheet’s titleblock to

UP

UP

UP

UP

UP

PRINCIPAL'SOFFICE

MAINOFFICE

STAFFBREAKROOM

ELLROOM

ELEV

3RDGRADE

ENGINEER'SOFFICE

CORRIDOR

2NDGRADE 2ND

GRADE

CORRIDOR

2NDGRADE

2NDGRADE CITYWIDE

4/5 MEDIACENTER /

COMPUTERLAB

JANITOR

GYM

STORAGE

NURSEOFFICE

NURSE TOILET

SPECIALED.

MUSICROOM

HIGH-5RESOURCEROOM

CORRIDOR

3RDGRADE

4THGRADE

5THGRADE 4TH

GRADE

ART5TH

GRADE

CONF.ROOM

1STGRADE

1STGRADE

1STGRADE

KINDERGARTEN

KINDERGARTEN

KINDERGARTEN

TUTORING

3 4 T H A V E N E

U

L Y

S

S

E

S

S

T

N

E

RESTRIPE PARKING; SEE CIVIL

A-113A2

A-111B1

REMOVE EXISTING MONUMENT SIGN; INSTALL NEW MONUMENT SIGN IN

SAME PLACE; CONNECT TO EXISTINGPOWER & DATA (V.I.F.)

MEETINGROOM

ARTS &CRAFTS

LOBBY

RECEPTION

MECH.STORAGE,JANITOR

LOUNGE

KILNROOM

STORAGE

GAMEROOM

MULTIPURPOSEROOM

STORAGE

KITCHEN

OFFICE WORKROOM

EXISTING FLAGPOLE TO REMAIN

EXISTING BENCHES TO REMAIN

NEW CURB RAMP & RECONSTRUCTED SIDEWALK AT HATCHED AREA; SEE CIVIL

(E) GENERATOR & PAD TO REMAIN;REMOVE EXISTING CHAIN-LINK SCREENING

RECONSTRUCTED ARCHITECTURAL STEEL

FRAMED TRELLIS;SEE DETAILS ON SHEET A-181

H A

Y E

S

S

T

N E

W I

L S

H I

R E

P L

N E

NEW ADA PARKING SIGNAGE;SEE CIVIL

EXISTING RAMP & HANDRAIL TO REMAIN

PROVIDE ALTERNATE PRICING ELEVATOR ADDITION AND SANITARY STUB-IN AND

ASSOCIATED CONSTRUCTION; SEEALTERNATE #1 IN THE SPECIFICATIONS

REFER TO MEP & CIVIL.

A-011 F1

TY

P.

PROVIDE ALTERNATE PRICING FOR THE REPLACEMENT OF

EXISTING MONUMENT SIGN; SEE ALTERNATE #2 IN THE SPECIFICATIONS

EXISTING STRIPING TO REMAIN; SEE CIVIL

NO PARKING BEYOND THIS POINT SIGN; SEE CIVIL

(E) TRANSFORMER & PAD TO REMAIN

ENTRYHALL

MAINENTRY

LOBBY

PROPERTY LINE; SEE CIVIL

PROPERTY LINE; SEE CIVIL

TWO-WAY TRAFFIC

TW

O-W

AY

TR

AF

FIC

TWO-WAY TRAFFIC

TWO-WAY TRAFFIC

TW

O-W

AY

TR

AF

FIC

ON

E-W

AY

TRA

FFIC

ONE-WAY TRAFFIC

EXISTING HARD-COVER PLAY AREA TO REMAIN

SEE CIVIL FOR EXISTING SIDEWALKS

SEE CIVIL FOR EXISTING SIDEWALKS

RELOCATE EXISTING BIKE RACKS HERE

SEE CIVIL FOR NEW SIDEWALK & CURB IN THESE AREAS

DO NOT SCALE DRAWINGS

SEE TITLEBLOCK FOR OVERALL KEYPLAN

FIELD VERIFY ALL DIMENSIONS.

G.C. TO VERIFY EXISTING SITE CONDITIONS PRIOR TO DEMOLITION OR CONSTRUCTION. IMMEDIATELY NOTIFY ARCHITECT OF ANY DISCREPANCIES.

SEE LANDSCAPE ARCHITECTURE DOCUMENTS FOR PLANT LOCATIONS AND TYPES INCLUDING SCREENING ALONG 34TH AVE NE.

FIRST FLOOR BUILDING PLAN SHOWN HERE FOR REFERENCE ONLY. REFER TO SHEETS A-100 THRU A-113 FOR CONSTRUCTION PLANS

SEE CIVIL ENGINEERING DOCUMENTS FOR UTILITIES, GRADING, STORMWATER, AND DIMENSIONAL SITE REQUIREMENTS

SEE ELECTRICAL SHEETS FOR EXTERIOR LIGHTING

A.

B.

C.

D.

E.

F.

G.

H.

GENERAL NOTES - SITE PLAN

3/4" PREFIN. ALUM. PLATE ON 1" STANDOFFS; MOUNT TO MASONRY BEYOND

WATERJET CUTOUT LETTERS;'AVENIR' TYPE FACE

1/2" THICK PREFIN ALUM. GRAPHIC LOGO;CUTOUT LETTERS; FLUSH MOUNT TO ALUMPLATE BEYOND; MPS LOGO CAD FILE TO BE PROVIDED BY OWNER; COLOR SELECTIONBY OWNER

2" 5'-0" 2"

1'-8" 4 1/4"

CL

EQ EQ

6"

5"1'

-0"

1"6"

EQ

.E

Q.

1/2" THICK PREFIN ALUM. MASCOT LOGO;CUTOUT LETTERS; FLUSH MOUNT TO ALUMPLATE BEYOND; LOGO CAD FILE TO BE PROVIDED BY OWNER; COLOR SELECTIONBY OWNER

2"8"

2"

5'-4"

2'-1

0"

TWO (2) JUNCTIONBOXES; SEE ELECTRICAL

1"6'-0

"

MIN

.

1'-4

"

LED SCREEN

CHAMFER SHORT SIDESOF CAP TO MATCH SLOPEOF CHAMFER ON LONG SIDES.SEE DTL

A-011F2

/F5 A-011

F4

A-0117'

-10"

FIELD VERIFY SLOPE OF GRADE

CONT. MTL. FLASHING OVER TOP OF WALL

5"1"

WEEP VENT AT 24" O.C.

DOWELS PER SECTION

0' - 3" TYP

BOND BEAM, REINFORCE WITH 2-#5 CONT

PROVIDE 1/4" GAP TO ALLOW FOR EXPANSION

LAYER OF FLEXIBLE FLASHING BELOW AND ON TOP OF REINFORCEMENT, SEAL AROUND

SEALANT, ENTIRE PERIMETER

PRECAST CONCRETE CAP

SIDES1" ALL

DRIP EDGE ENTIRE PERIMETER

HORIZONTAL REINFORCEMENT

PER SECTIONWALL ASSEMBLY

EXPANSION JOINT FILLER SEAL TOP 1/2" WITH ELASTOMERIC SEALANT, SEE ALSO CIVIL

PER SECTIONWALL ASSEMBLY

TWO (2) CONDUIT FOR SIGNS, SEE ELEC

CONCRETE MAINTENANCE STRIP PER CIVIL

FOOTING PER SECTION

8" CMU #5 AT 16" O.C. DOWELS TO MATCH VERTICAL REINFORCING. LAP 30" MIN.

4" FACE BRICK ALL SIDES

CAST-IN-PLACE 5'-0" x 1'-6" FOOTING AND FOUNDATION

#5 AT 16" O.C. VERTICAL EACH FACE#5 AT 16" O.C. HORIZONTAL EACH FACE

DOWELS FROM FOOTING WITH STANDARD HOOK, MATCH WALL REINFORCEMENT SPACING AND LAP 30" MIN

MIN

.

4'-0

"

_______F6A-011

_______F5A-011

NO WORK IN INDICATED HATCHED AREAS

GENERAL NOTE - NO WORK

www.mpls.k12.mn.us

Scale

Project number

Date

Drawn by

Checked by

I hereby certify this plan, specification or report was prepared by me or under my direct supervision and that I am a duly

Licensed Architect under the laws of the state of

MINNESOTA

Date: Reg. No: 21241

Pamela Bakken Anderson

KEY PLAN

A

1

B

C

D

E

F

A

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

ISSUED:

As indicated

A-011

SITE PLAN & OVERALLPLAN - FIRST FLOOR

19038.00

OP#20-2924 SAFE/SECUREENTRANCE PROJECT

WAITE PARK ELEMENTARY

03/12/2020

ZHF/MMA

PBA

1800 34th Ave NE, Minneapolis, MN 55418

03/12/2020

03/12/2020

BID DOCUMENTS

1" = 20'-0"A1 SITE PLAN

N

AB

C

DREC.CENTER

3/4" = 1'-0"F2 SIGNAGE DETAIL @ MONUMENT SIGN

1/4" = 1'-0"F1 TYP. ELEVATION @ MONUMENT SIGN

1 1/2" = 1'-0"F5 SECTION AT CAP

1 1/2" = 1'-0"F6 SECTION AT BASE

1/4" = 1'-0"F4 SECTION THROUGH MONUMENT SIGN

PROVIDE ALTERNATE PRICING FOR THE REPLACEMENT OF EXISTING MONUMENT SIGN; SEE ALTERNATE #2 IN THE SPECIFICATIONS

No. Description Date1 ADDENDUM NO.1 3/20/2020

1

1

Page 9: OP #20-2924 ADDENDUM No. 1 (ONE)...WAITE PARK ELEMENTARY ADDENDUM NO. 1 OP #20-2924 3/20/2020 SAFE/SECURE ENTRANCE PROJECT 2 1. Revise project title in each sheet’s titleblock to

UP

UP

UP

UP

UP

UP

UP

4.c

3.c

2.c

1.c

A.c B.c

C.b

15.b

8.b

16.b

14.b

12.b

10.b

D.b F.b J.b L.b N.b

M.b

P.b

6.b

3.b

1.b

E.b G.b H.b K.b

A.a

B.bA.b

7.b

5.b

4.b

2.b

11.b

13.b

9.b

B.aC.a

D.aE.a

F.a

3.a

1.a

6.a

7.a

C.c

10.2.b

/A

2A

D11

3M

AT

CH

LIN

EA

RE

A 'D

' @

54

07

TRANSFORMERVAULT

MECHANICAL

024BSTORAGE

024A

BOILER ROOM

024ELECTRICAL

025

JANITOR

026

CORRIDOR

000B

MEN'SRESTROOM

022

WOMEN'SRESTROOM

021

JANITOR

023

ELL ROOM

003

KITCHEN

017

SERVING

020A

LUNCHROOM

020

AUDITORIUM

008

STAGE

008A

MECHANICAL

007

BOOK ROOM

006

MECHANICAL

005COMPUTER LAB

004

CRAWL SPACE

020B

ELEV

-

19

9' -

4"

E.cD.c

1.5.c

2.5.c

C.5.a

F.c

3.8.b

20

11' -

7"

55

PROVIDE ALTERNATE PRICINGFOR REPLACEMENT OF

EXISITINGELEVATOR & ASSOCIATED

CONSTRUCTION; SEE ALTERNATE #1 IN THE

SPECIFICATIONS

42

3'-1

0"3'

-9 3

/4"

69

10' - 0"

2'-0

"

3'-0

"

561'

-8"

2'-0"

PROVIDE ALTERNATE PRICING FOR STUB-IN OF SANITARY

SEWER & ASSOCIATED CONSTRUCTION; SEE

ALTERNATE #1 IN THE SPECIFICATIONS; SEE MEP

3'-1

0"

(V.I.F.)

6'-9 1/2"

1

1

DO NOT SCALE DRAWINGS

FIELD VERIFY THE EXTENT OF DEMOLITION REQUIRED TO COMPLETE THE WORK IDENTIFIED WITHIN THE CONSTRUCTION DOCUMENTS. THE DRAWINGS MAY NOT INDICATE ALL ITEMS REQUIRED TO BE REMOVED DURING DEMOLITION.

ALL DIMENSIONS FOR DEMOLITION ARE APPROXIMATE. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES GREATER THAN ONE INCH.

DEMOLITION ACTIVITIES ARE TO INCLUDE ALL NECESSARY DEMOLITION FOR INSTALLATION OF NEW UTILITIES, MECHANICAL, PLUMBING, ELECTRICAL, AND LIFESAFETY SYSTEMS.

REFER TO MEP SHEETS FOR THE FULL EXTENT OF MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS TO BE REMOVED AND/OR RELOCATED.

VERIFY ANY AND ALL ITEMS TO BE SALVAGED WITH BUILDING OWNER. PROTECT ALL SUCH ITEMS. STOCKPILE ITEMS AND MATERIALS IN LOCATIONS AS DIRECTED BY BUILDING OWNER.

A.

B.

C.

D.

E.

F.

GENERAL NOTES - DEMOLITIONIDENTIFY AND REPORT TO OWNER ANY AND ALL HAZARDOUS MATERIALS REQUIRING ABATEMENT. OWNER TO PERFORM ABATEMENT ACTIVITIES IN ACCORDANCE WITH ALL APPLICABLE LAWS, ORDINANCE, AND SAFETY REQUIREMENTS.

REMOVE AND RE-ROUTE EXISTING UTILITES AS NECESSARY TO ACCOMODATE NEW WORK.

MAINTAIN ACCESS TO ANY AND ALL EMERGENCY EXITS DURING DEMOLITION.

G.

F.

G.

NO WORK IN INDICATED HATCHED AREAS

GENERAL NOTE - NO WORK

www.mpls.k12.mn.us

Scale

Project number

Date

Drawn by

Checked by

I hereby certify this plan, specification or report was prepared by me or under my direct supervision and that I am a duly

Licensed Architect under the laws of the state of

MINNESOTA

Date: Reg. No: 21241

Pamela Bakken Anderson

KEY PLAN

A

1

B

C

D

E

F

A

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

ISSUED:

As indicated

AD101

GROUND FLOOR DEMOPLANS

19038.00

OP#20-2924 SAFE/SECUREENTRANCE PROJECT

WAITE PARK ELEMENTARY

03/12/2020

ZHF/MMA

PBA

1800 34th Ave NE, Minneapolis, MN 55418

03/12/2020

03/12/2020

BID DOCUMENTS

1/8" = 1'-0"A1 DEMO GROUND FL. AREAS 'B' & 'C'

N

KEYNOTES - DEMOLITION

01 REMOVE EXISTING VCT FLOORING & ASSOCIATED WALL BASE THROUGHOUT THIS SPACE.02 EXISTING FLOORING IN THIS SPACE TO REMAIN.03 EXISTING FLOORING IN THIS SPACE TO BE REMOVED BY OWNER.04 REMOVE INDICATED MASONRY WALLS. COORDINATE WITH OWNER FOR SALVAGE OR DISPOSAL OF ANY ASSOCIATED TACKBOARD, CHALKBOARDS, AND/OR TACK STRIPS (IF APPLICABLE)05 REMOVE INDICATED DOORS, FRAME AND TRANSOM ABOVE (IF APPLICABLE)06 REMOVE WINDOW ASSEMBLIES, EXTERIOR SLATE VENEER, AND EXTERIOR SLATE SILL BETWEEN THESE PIERS; INTERIOR SLATE SILL TO REMAIN U.N.O.; SALVAGE SLATE MATERIALS FOR

REUSE IN NEW CONSTRUCTION.

07 REMOVE EXISTING ELEVATOR, ELEVATOR DOORS, JAMBS & ASSOCIATED EQUIPMENT.08 REMOVE DISPLAY CASE INCLUDING SLIDING GLASS PANELS, SLATE SHELF, LOW BRICK WALLS & ASSOCIATED MILLWORK. REMOVE ANY EXISTING FLOOR TOPPING UNDER DISPLAY CASE.

SALVAGE BRICKS & SLATE FOR POTENTIAL REUSE IN NEW CONSTRUCTION.

09 NOT USED10 REMOVE EXISTING ELEVATOR MACHINE ROOM & ASSOCIATED EQUIPMENT.11 NOT USED12 NOT USED13 NOT USED14 REMOVE ROOF OF ENTRY TRELLIS/CANOPY OVERHEAD. EXISTING COLUMNS AND BEAMS TO REMAIN UNLESS NOTED OTHERWISE.15 NOT USED16 SAWCUT AND REMOVE INDICATED PORTION OF MASONRY WALL & INTERIOR SLATE SILL DOWN TO STRUCTURAL CONCRETE FLOOR SLAB17 REMOVE THIS COLUMN AND BEAM18 REMOVE THESE BEAMS OVERHEAD19 REMOVE THIS WINDOW FRAME ASSEMBLY INCLUDING LOUVERS & SOLID INFILL PANEL. DUCTS ASSOCIATED WITH THESE LOUVERS TO BE REROUTED. FIELD VERIFY SIZE OF EXISTING

LOUVERS. SEE MEP.

20 REMOVE EXISTING ELEVATOR DOOR, JAMB, ASSOCIATED EQUIPMENT AND INDICATED EXTENTS OF THIS WALL TO ACCOMODATE THE INSTALLATION OF NEW ELEVATOR DOOR & JAMB.VERIFY SIZE OF NEW R.O. WITH ELEVATOR SUPPLIER.

21 REMOVE EXISTING RADIANT HEATERS & ASSOCIATED MILLWORK ENCLOSURE ALONG THIS WALL. SEE MEP. (E) SLATE SILL TO REMAIN IN OFFICE SPACES.22 EXISTING CHILLER PIPING CHASE TO BE REMAIN. FIELD VERIFY DIMENSIONS.23 NOT USED24 NOT USED25 NOT USED26 NOT USED27 REMOVE INDICATED PORTION OF MASONRY WALL TO CONCRETE BEAM ABOVE. FIELD VERIFY HEIGHT OF BEAM.28 EXISTING RAINWATER LEADER CHASE TO REMAIN. FIELD VERIFY DIMENSIONS.29 REMOVE EXISTING CASEWORK/MILLWORK & COUNTER (AS APPLICABLE)30 REMOVE EXISTING ELECTRICAL CHASE. ELECTRICAL EQUIPMENT TO REMAIN IN PLACE.31 REMOVE EXISTING SINK AND FAUCET. SEE MEP.32 REMOVE EXISTING WINDOW SHADES/BLINDS & ASSOCIATED HARDWARE AT THIS BANK OF WINDOWS.33 REMOVE INDICATED PORTION OF STONE TILE FLOORING AT FIREPLACE HEARTH. SALVAGE TILES FOR REUSE ELSWHERE. REFER TO NEW CONSTRUCTION DOCUMENTS FOR FULL EXTENT.35 REMOVE RECESSED WALL SAFE. SAVE FOR REUSE.36 REMOVE TACKSTRIPS, TACKBOARDS, CHALKBOARDS & ASSOCIATED HARDWARE ALONG THIS WALL.37 REMOVE AND SALVAGE EMPLOYEE MAIL SLOTS FOR RELOCATION DURING NEW CONSTRUCTION. REFER TO CONSTRUCTION PLANS FOR NEW LOCATION.38 EXISTING BENCH TO REMAIN.39 EXISTING CHALKBOARD TO REMAIN.40 REMOVE EXISTING PROJECTOR SCREEN (ABOVE) & ASSOCIATED HARDWARE.41 REMOVE OVERHEAD PROJECTOR IN THIS ROOM. SEE MEP. RETURN EQUIPMENT TO OWNER.42 REMOVE INDICATED EXTENT OF CAST IN PLACE CONCRETE WALL DOWN TO FOOTING. SEE STRUCTURAL FOR MORE INFO.43 NOT USED44 REMOVE GRILLE AT TOP OF FIN-TUBE RADIANT HEATER CABINET. EXISTING CABINET & RADIANT HEATING TO REMAIN.45 NOT USED46 NOT USED47 NOT USED48 NOT USED49 NOT USED50 NOT USED51 NOT USED52 EXISTING CASEWORK, TRIM, AND ASSOCIATED FIXTURES TO REMAIN53 REMOVE INDICATED AREA OF FLOOR/CEILING/ROOF ASSEMBLY IN PREPARATION FOR NEW HVAC CHASE. DO NOT OVERCUT. DO NOT CUT INTO EXISTING JOISTS. SEE MEP FOR MORE

INFO.54 REMOVE SOUTH EXTERIOR SHAFT WALL AT ELEVATOR DOWN TO FOOTING. SEE STRUCTURAL55 REMOVE EXISTING ELEVATOR PIT SLAB.56 REMOVE INDICATED EXTENT OF SLAB, CT FLOOR FINISH & EXISTING CONCRETE MOP SINK IN PREPARATION FOR NEW SANITARY SEWER CONNECTION; SEE MEP. SALVAGE CT FLOORING

FOR REUSE IN NEW CONSTRUCTION.

57 EXISTING STONE TILE FLOORING AT FIREPLACE TO REMAIN.58 REMOVE EXISTING EXTERIOR DOOR, WINDOW & FRAME ASSEMBLY INCLUDING ANY ASSOCIATED HARDWARE.59 REMOVE EXISTING WIRE MESH PARTITION ASSEMBLY INCLUDING INDICATED DOOR, FRAME, AND HANDRAILS.60 NOT USED61 NOT USED62 NOT USED63 NOT USED64 REMOVE EXISTING BIKE RACKS; SALVAGE FOR REINSTALLATION; SEE SITE PLAN65 REMOVE EXISTING CANOPY ROOF DRAIN AND RWL BACK TO MAIN AND CAP; SEE MEP66 REMOVE EXISTING CANOPY ROOF DRAIN AND RWL BACK TO EXTERIOR WALL. CONNECT NEW ROOF DRAIN TO EXISTING PIPING.67 EXISTING FLOORING IN THIS SPACE TO BE REMOVED BY OWNER.68 REMOVE APPROXIMATELY 40 SQ. FT OF EXISTING VCT FLOORING ADJACENT TO EXISTING ELEVATOR MACHINE ROOM IN PREPARATION FOR NEW INFILL VCT. ONLY REMOVE WHOLE TILES

AND SQAURE OFF AREA REMOVED TO MATCH PATTERN OF EXISTING VCT LAYOUT.69 REMOVE INDICATED AREA OF VCT FLOORING & SLAB IN PREPARATION FOR NEW SANITARY SEWER STUB-IN. REMOVE WHOLE TILES ONLY.70 REMOVE INFILL STUD WALL TO BOTTOM OF EXISTING SOFFIT ABOVE; EXISTING BULKHEAD & SOFFIT TO REMAIN; FIELD VERIFY HEIGHT OF SOFFIT.

B

C

No. Description Date1 ADDENDUM NO.1 3/20/2020

1

Page 10: OP #20-2924 ADDENDUM No. 1 (ONE)...WAITE PARK ELEMENTARY ADDENDUM NO. 1 OP #20-2924 3/20/2020 SAFE/SECURE ENTRANCE PROJECT 2 1. Revise project title in each sheet’s titleblock to

DN

DN

DN

DN

DN

2.c

1.c

A.c

C.b

15.b

8.b

14.b

10.b

D.b F.b J.b L.b N.b P.b

6.b

3.b

1.b

E.b G.b H.b K.bA.a

B.bA.b

7.b

5.b

4.b

2.b

11.b

13.b

9.b

C.a

3.a

1.a

6.a

7.a10.2.b

/A

2A

D11

3M

AT

CH

LIN

EA

RE

A 'D

' @

OFFICE

129

STORAGE

130A

GENERALOFFICE

130

COPIER

130B

SOCIAL WORKER

130C

OFFICE

131BNURSE

131

NURSE

131A

GYM

128

CORRIDOR

100B

MUSIC ROOM

102

OFFICES

101 ENGINEER'SOFFICE

126

STORAGE

128A

ELEV

-

67

67

67

01

67

07

04

70 05

05

08

05

04

3'-4

"

2'-2

3/8

"

OFFICE

-

0505

04

6767

14

16

17

18

21

22

STORAGE

PB122

MEETING ROOM

PB120

MECH., JANITOR

PB121

ARTS & CRAFTS

PB117WOMEN'S

RESTROOMPB119

MEN'SRESTROOM

PB118

LOBBY

PB103

RECEPTION

PB106

STORAGE

PB115KILN ROOM

PB116

LOUNGE

PB114

WORK ROOM

PB108

OFFICE

PB107

GAME ROOM

PB109

MULTIPURPOSEROOM

PB110

STORAGE

PB111

KITCHEN

PB113

E.c

1.5.c

2.5.c

C.5.a

F.c

3.8.b

5'-1

0"

28

2970

04

21

31

2905

27

06

32

32

32

32

32 32 32

33

57

8'-1

1/4

"

04

05

35

36

29

38

32

32

39

40

4129

37 36

V.I.F.

4'-0"2970

44

1717

58

59

53

1'-10"1'-0

"

PROVIDE ALTERNATE PRICINGFOR REPLACEMENT OF EXISITINGELEVATOR & ASSOCIATEDCONSTRUCTION; SEE ALTERNATE #1IN THE SPECIFICATIONS

A2

AD111

53

8" 23'-5 3/4"

8"10

'-1 5

/8"

36

36

36

ELEVATORLOBBY

100E

64

65

66

5'-2"

44

44

01

52

52

39SPECIAL ED.

109

STAFF

110

3RD GRADE

108

RESOURCEROOM

111

HI-5

112

02

02

02

02

02

02

02

0202

(V.I.F.)

6'-9 1/2"

1

3'-1

0"3'

-7"

1

DO NOT SCALE DRAWINGS

FIELD VERIFY THE EXTENT OF DEMOLITION REQUIRED TO COMPLETE THE WORK IDENTIFIED WITHIN THE CONSTRUCTION DOCUMENTS. THE DRAWINGS MAY NOT INDICATE ALL ITEMS REQUIRED TO BE REMOVED DURING DEMOLITION.

ALL DIMENSIONS FOR DEMOLITION ARE APPROXIMATE. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES GREATER THAN ONE INCH.

DEMOLITION ACTIVITIES ARE TO INCLUDE ALL NECESSARY DEMOLITION FOR INSTALLATION OF NEW UTILITIES, MECHANICAL, PLUMBING, ELECTRICAL, AND LIFESAFETY SYSTEMS.

REFER TO MEP SHEETS FOR THE FULL EXTENT OF MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS TO BE REMOVED AND/OR RELOCATED.

VERIFY ANY AND ALL ITEMS TO BE SALVAGED WITH BUILDING OWNER. PROTECT ALL SUCH ITEMS. STOCKPILE ITEMS AND MATERIALS IN LOCATIONS AS DIRECTED BY BUILDING OWNER.

A.

B.

C.

D.

E.

F.

GENERAL NOTES - DEMOLITIONIDENTIFY AND REPORT TO OWNER ANY AND ALL HAZARDOUS MATERIALS REQUIRING ABATEMENT. OWNER TO PERFORM ABATEMENT ACTIVITIES IN ACCORDANCE WITH ALL APPLICABLE LAWS, ORDINANCE, AND SAFETY REQUIREMENTS.

REMOVE AND RE-ROUTE EXISTING UTILITES AS NECESSARY TO ACCOMODATE NEW WORK.

MAINTAIN ACCESS TO ANY AND ALL EMERGENCY EXITS DURING DEMOLITION.

G.

F.

G.

(E) SLATE SILL TO REMAIN

REMOVE (E) METAL GRILLE

REMOVE (E) WOOD LEDGE

REMOVE (E) BLOCKING

REMOVE (E) METAL STRAP SUPPORTS

REMOVE (E) FIBERGLASS INSULATION BOARDS

REMOVE (E) WD VENEER PANEL

REMOVE (E) FIN TUBE RADIANT HEATERS; SEE MEP

REMOVE (E) WALL BASE & FLOOR FINISHES

(E) MASONRY WALL & STRUCTURAL FLOOR SLAB TO REMAIN; PREP SURFACES TO RECEIVE NEW FINISHES

4 1/4"

(E) BLOCKING @ BRICK TO REMAIN

NO WORK IN INDICATED HATCHED AREAS

GENERAL NOTE - NO WORK

www.mpls.k12.mn.us

Scale

Project number

Date

Drawn by

Checked by

I hereby certify this plan, specification or report was prepared by me or under my direct supervision and that I am a duly

Licensed Architect under the laws of the state of

MINNESOTA

Date: Reg. No: 21241

Pamela Bakken Anderson

KEY PLAN

A

1

B

C

D

E

F

A

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

ISSUED:

As indicated

AD111

FIRST FLOOR DEMO PLANS

19038.00

OP#20-2924 SAFE/SECUREENTRANCE PROJECT

WAITE PARK ELEMENTARY

03/12/2020

ZHF/MMA

PBA

1800 34th Ave NE, Minneapolis, MN 55418

03/12/2020

03/12/2020

BID DOCUMENTS

1/8" = 1'-0"A3 DEMO FIRST FLOOR AREA 'B'

B

REC.CENTER

KEYNOTES - DEMOLITION

01 REMOVE EXISTING VCT FLOORING & ASSOCIATED WALL BASE THROUGHOUT THIS SPACE.02 EXISTING FLOORING IN THIS SPACE TO REMAIN.03 EXISTING FLOORING IN THIS SPACE TO BE REMOVED BY OWNER.04 REMOVE INDICATED MASONRY WALLS. COORDINATE WITH OWNER FOR SALVAGE OR DISPOSAL OF ANY ASSOCIATED TACKBOARD, CHALKBOARDS, AND/OR TACK STRIPS (IF APPLICABLE)05 REMOVE INDICATED DOORS, FRAME AND TRANSOM ABOVE (IF APPLICABLE)06 REMOVE WINDOW ASSEMBLIES, EXTERIOR SLATE VENEER, AND EXTERIOR SLATE SILL BETWEEN THESE PIERS; INTERIOR SLATE SILL TO REMAIN U.N.O.; SALVAGE SLATE MATERIALS FOR

REUSE IN NEW CONSTRUCTION.

07 REMOVE EXISTING ELEVATOR, ELEVATOR DOORS, JAMBS & ASSOCIATED EQUIPMENT.08 REMOVE DISPLAY CASE INCLUDING SLIDING GLASS PANELS, SLATE SHELF, LOW BRICK WALLS & ASSOCIATED MILLWORK. REMOVE ANY EXISTING FLOOR TOPPING UNDER DISPLAY CASE.

SALVAGE BRICKS & SLATE FOR POTENTIAL REUSE IN NEW CONSTRUCTION.09 NOT USED10 REMOVE EXISTING ELEVATOR MACHINE ROOM & ASSOCIATED EQUIPMENT.11 NOT USED12 NOT USED13 NOT USED14 REMOVE ROOF OF ENTRY TRELLIS/CANOPY OVERHEAD. EXISTING COLUMNS AND BEAMS TO REMAIN UNLESS NOTED OTHERWISE.15 NOT USED16 SAWCUT AND REMOVE INDICATED PORTION OF MASONRY WALL & INTERIOR SLATE SILL DOWN TO STRUCTURAL CONCRETE FLOOR SLAB17 REMOVE THIS COLUMN AND BEAM18 REMOVE THESE BEAMS OVERHEAD19 REMOVE THIS WINDOW FRAME ASSEMBLY INCLUDING LOUVERS & SOLID INFILL PANEL. DUCTS ASSOCIATED WITH THESE LOUVERS TO BE REROUTED. FIELD VERIFY SIZE OF EXISTING

LOUVERS. SEE MEP.

20 REMOVE EXISTING ELEVATOR DOOR, JAMB, ASSOCIATED EQUIPMENT AND INDICATED EXTENTS OF THIS WALL TO ACCOMODATE THE INSTALLATION OF NEW ELEVATOR DOOR & JAMB.VERIFY SIZE OF NEW R.O. WITH ELEVATOR SUPPLIER.

21 REMOVE EXISTING RADIANT HEATERS & ASSOCIATED MILLWORK ENCLOSURE ALONG THIS WALL. SEE MEP. (E) SLATE SILL TO REMAIN IN OFFICE SPACES.22 EXISTING CHILLER PIPING CHASE TO BE REMAIN. FIELD VERIFY DIMENSIONS.23 NOT USED24 NOT USED25 NOT USED26 NOT USED27 REMOVE INDICATED PORTION OF MASONRY WALL TO CONCRETE BEAM ABOVE. FIELD VERIFY HEIGHT OF BEAM.28 EXISTING RAINWATER LEADER CHASE TO REMAIN. FIELD VERIFY DIMENSIONS.29 REMOVE EXISTING CASEWORK/MILLWORK & COUNTER (AS APPLICABLE)30 REMOVE EXISTING ELECTRICAL CHASE. ELECTRICAL EQUIPMENT TO REMAIN IN PLACE.31 REMOVE EXISTING SINK AND FAUCET. SEE MEP.32 REMOVE EXISTING WINDOW SHADES/BLINDS & ASSOCIATED HARDWARE AT THIS BANK OF WINDOWS.33 REMOVE INDICATED PORTION OF STONE TILE FLOORING AT FIREPLACE HEARTH. SALVAGE TILES FOR REUSE ELSWHERE. REFER TO NEW CONSTRUCTION DOCUMENTS FOR FULL EXTENT.35 REMOVE RECESSED WALL SAFE. SAVE FOR REUSE.36 REMOVE TACKSTRIPS, TACKBOARDS, CHALKBOARDS & ASSOCIATED HARDWARE ALONG THIS WALL.37 REMOVE AND SALVAGE EMPLOYEE MAIL SLOTS FOR RELOCATION DURING NEW CONSTRUCTION. REFER TO CONSTRUCTION PLANS FOR NEW LOCATION.38 EXISTING BENCH TO REMAIN.39 EXISTING CHALKBOARD TO REMAIN.40 REMOVE EXISTING PROJECTOR SCREEN (ABOVE) & ASSOCIATED HARDWARE.41 REMOVE OVERHEAD PROJECTOR IN THIS ROOM. SEE MEP. RETURN EQUIPMENT TO OWNER.42 REMOVE INDICATED EXTENT OF CAST IN PLACE CONCRETE WALL DOWN TO FOOTING. SEE STRUCTURAL FOR MORE INFO.43 NOT USED44 REMOVE GRILLE AT TOP OF FIN-TUBE RADIANT HEATER CABINET. EXISTING CABINET & RADIANT HEATING TO REMAIN.45 NOT USED46 NOT USED47 NOT USED48 NOT USED49 NOT USED50 NOT USED51 NOT USED52 EXISTING CASEWORK, TRIM, AND ASSOCIATED FIXTURES TO REMAIN53 REMOVE INDICATED AREA OF FLOOR/CEILING/ROOF ASSEMBLY IN PREPARATION FOR NEW HVAC CHASE. DO NOT OVERCUT. DO NOT CUT INTO EXISTING JOISTS. SEE MEP FOR MORE

INFO.

54 REMOVE SOUTH EXTERIOR SHAFT WALL AT ELEVATOR DOWN TO FOOTING. SEE STRUCTURAL55 REMOVE EXISTING ELEVATOR PIT SLAB.56 REMOVE INDICATED EXTENT OF SLAB, CT FLOOR FINISH & EXISTING CONCRETE MOP SINK IN PREPARATION FOR NEW SANITARY SEWER CONNECTION; SEE MEP. SALVAGE CT FLOORING

FOR REUSE IN NEW CONSTRUCTION.57 EXISTING STONE TILE FLOORING AT FIREPLACE TO REMAIN.58 REMOVE EXISTING EXTERIOR DOOR, WINDOW & FRAME ASSEMBLY INCLUDING ANY ASSOCIATED HARDWARE.59 REMOVE EXISTING WIRE MESH PARTITION ASSEMBLY INCLUDING INDICATED DOOR, FRAME, AND HANDRAILS.60 NOT USED61 NOT USED62 NOT USED63 NOT USED64 REMOVE EXISTING BIKE RACKS; SALVAGE FOR REINSTALLATION; SEE SITE PLAN65 REMOVE EXISTING CANOPY ROOF DRAIN AND RWL BACK TO MAIN AND CAP; SEE MEP66 REMOVE EXISTING CANOPY ROOF DRAIN AND RWL BACK TO EXTERIOR WALL. CONNECT NEW ROOF DRAIN TO EXISTING PIPING.67 EXISTING FLOORING IN THIS SPACE TO BE REMOVED BY OWNER.68 REMOVE APPROXIMATELY 40 SQ. FT OF EXISTING VCT FLOORING ADJACENT TO EXISTING ELEVATOR MACHINE ROOM IN PREPARATION FOR NEW INFILL VCT. ONLY REMOVE WHOLE TILES

AND SQAURE OFF AREA REMOVED TO MATCH PATTERN OF EXISTING VCT LAYOUT.

69 REMOVE INDICATED AREA OF VCT FLOORING & SLAB IN PREPARATION FOR NEW SANITARY SEWER STUB-IN. REMOVE WHOLE TILES ONLY.70 REMOVE INFILL STUD WALL TO BOTTOM OF EXISTING SOFFIT ABOVE; EXISTING BULKHEAD & SOFFIT TO REMAIN; FIELD VERIFY HEIGHT OF SOFFIT.

N

1 1/2" = 1'-0"A2 DEMO DETAIL @ ENCLOSED RADIANT HEATERS

No. Description Date1 ADDENDUM NO.1 3/20/2020

1

1

Page 11: OP #20-2924 ADDENDUM No. 1 (ONE)...WAITE PARK ELEMENTARY ADDENDUM NO. 1 OP #20-2924 3/20/2020 SAFE/SECURE ENTRANCE PROJECT 2 1. Revise project title in each sheet’s titleblock to

UP

UP

A.b

V.d

U.d

Q.d

P.d

N.d

M.d

L.d

K.d

J.d

E.d

D.d

B.d

1.d

5.d

2.d

8.d

11.d

14.d

16.d

7.d

15.d

/A

3A

D11

1M

AT

CH

LIN

EF

IRS

T F

L A

RE

A 'B

' @

/A

1A

D10

1G

R.

FL

AR

EA

'B' &

'C' @

54

0710

05

04

KINDERGARTEN

123

TUTORING

125

KINDERGARTEN

124

KINDERGARTEN

122

1ST GRADE

121

1ST GRADE

120

1ST GRADE

119

CORRIDOR

100D

ELEV. MECH

140

ELEV

02

01

30

55

3'-1

0"2'

-9"

20

PROVIDE ALTERNATE PRICINGFOR REPLACEMENT OF EXISITING

ELEVATOR & ASSOCIATEDCONSTRUCTION; SEE ALTERNATE #1

IN THE SPECIFICATIONS

68

(V.I.F.)

6'-9 1/2"

1

DO NOT SCALE DRAWINGS

FIELD VERIFY THE EXTENT OF DEMOLITION REQUIRED TO COMPLETE THE WORK IDENTIFIED WITHIN THE CONSTRUCTION DOCUMENTS. THE DRAWINGS MAY NOT INDICATE ALL ITEMS REQUIRED TO BE REMOVED DURING DEMOLITION.

ALL DIMENSIONS FOR DEMOLITION ARE APPROXIMATE. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES GREATER THAN ONE INCH.

DEMOLITION ACTIVITIES ARE TO INCLUDE ALL NECESSARY DEMOLITION FOR INSTALLATION OF NEW UTILITIES, MECHANICAL, PLUMBING, ELECTRICAL, AND LIFESAFETY SYSTEMS.

REFER TO MEP SHEETS FOR THE FULL EXTENT OF MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS TO BE REMOVED AND/OR RELOCATED.

VERIFY ANY AND ALL ITEMS TO BE SALVAGED WITH BUILDING OWNER. PROTECT ALL SUCH ITEMS. STOCKPILE ITEMS AND MATERIALS IN LOCATIONS AS DIRECTED BY BUILDING OWNER.

A.

B.

C.

D.

E.

F.

GENERAL NOTES - DEMOLITIONIDENTIFY AND REPORT TO OWNER ANY AND ALL HAZARDOUS MATERIALS REQUIRING ABATEMENT. OWNER TO PERFORM ABATEMENT ACTIVITIES IN ACCORDANCE WITH ALL APPLICABLE LAWS, ORDINANCE, AND SAFETY REQUIREMENTS.

REMOVE AND RE-ROUTE EXISTING UTILITES AS NECESSARY TO ACCOMODATE NEW WORK.

MAINTAIN ACCESS TO ANY AND ALL EMERGENCY EXITS DURING DEMOLITION.

G.

F.

G.

NO WORK IN INDICATED HATCHED AREAS

GENERAL NOTE - NO WORK

www.mpls.k12.mn.us

Scale

Project number

Date

Drawn by

Checked by

I hereby certify this plan, specification or report was prepared by me or under my direct supervision and that I am a duly

Licensed Architect under the laws of the state of

MINNESOTA

Date: Reg. No: 21241

Pamela Bakken Anderson

KEY PLAN

A

1

B

C

D

E

F

A

B

C

D

E

F

2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

ISSUED:

As indicated

AD113

FIRST FLOOR DEMO PLANS

19038.00

OP#20-2924 SAFE/SECUREENTRANCE PROJECT

WAITE PARK ELEMENTARY

03/12/2020

ZHF/MMA

PBA

1800 34th Ave NE, Minneapolis, MN 55418

03/12/2020

03/12/2020

BID DOCUMENTS

1/8" = 1'-0"A2 DEMO FIRST FL. AREA 'D'

D

KEYNOTES - DEMOLITION

01 REMOVE EXISTING VCT FLOORING & ASSOCIATED WALL BASE THROUGHOUT THIS SPACE.02 EXISTING FLOORING IN THIS SPACE TO REMAIN.03 EXISTING FLOORING IN THIS SPACE TO BE REMOVED BY OWNER.04 REMOVE INDICATED MASONRY WALLS. COORDINATE WITH OWNER FOR SALVAGE OR DISPOSAL OF ANY ASSOCIATED TACKBOARD, CHALKBOARDS, AND/OR TACK STRIPS (IF APPLICABLE)05 REMOVE INDICATED DOORS, FRAME AND TRANSOM ABOVE (IF APPLICABLE)06 REMOVE WINDOW ASSEMBLIES, EXTERIOR SLATE VENEER, AND EXTERIOR SLATE SILL BETWEEN THESE PIERS; INTERIOR SLATE SILL TO REMAIN U.N.O.; SALVAGE SLATE MATERIALS FOR

REUSE IN NEW CONSTRUCTION.07 REMOVE EXISTING ELEVATOR, ELEVATOR DOORS, JAMBS & ASSOCIATED EQUIPMENT.08 REMOVE DISPLAY CASE INCLUDING SLIDING GLASS PANELS, SLATE SHELF, LOW BRICK WALLS & ASSOCIATED MILLWORK. REMOVE ANY EXISTING FLOOR TOPPING UNDER DISPLAY CASE.

SALVAGE BRICKS & SLATE FOR POTENTIAL REUSE IN NEW CONSTRUCTION.

09 NOT USED10 REMOVE EXISTING ELEVATOR MACHINE ROOM & ASSOCIATED EQUIPMENT.11 NOT USED12 NOT USED13 NOT USED14 REMOVE ROOF OF ENTRY TRELLIS/CANOPY OVERHEAD. EXISTING COLUMNS AND BEAMS TO REMAIN UNLESS NOTED OTHERWISE.15 NOT USED16 SAWCUT AND REMOVE INDICATED PORTION OF MASONRY WALL & INTERIOR SLATE SILL DOWN TO STRUCTURAL CONCRETE FLOOR SLAB17 REMOVE THIS COLUMN AND BEAM18 REMOVE THESE BEAMS OVERHEAD19 REMOVE THIS WINDOW FRAME ASSEMBLY INCLUDING LOUVERS & SOLID INFILL PANEL. DUCTS ASSOCIATED WITH THESE LOUVERS TO BE REROUTED. FIELD VERIFY SIZE OF EXISTING

LOUVERS. SEE MEP.20 REMOVE EXISTING ELEVATOR DOOR, JAMB, ASSOCIATED EQUIPMENT AND INDICATED EXTENTS OF THIS WALL TO ACCOMODATE THE INSTALLATION OF NEW ELEVATOR DOOR & JAMB.

VERIFY SIZE OF NEW R.O. WITH ELEVATOR SUPPLIER.

21 REMOVE EXISTING RADIANT HEATERS & ASSOCIATED MILLWORK ENCLOSURE ALONG THIS WALL. SEE MEP. (E) SLATE SILL TO REMAIN IN OFFICE SPACES.22 EXISTING CHILLER PIPING CHASE TO BE REMAIN. FIELD VERIFY DIMENSIONS.23 NOT USED24 NOT USED25 NOT USED26 NOT USED27 REMOVE INDICATED PORTION OF MASONRY WALL TO CONCRETE BEAM ABOVE. FIELD VERIFY HEIGHT OF BEAM.28 EXISTING RAINWATER LEADER CHASE TO REMAIN. FIELD VERIFY DIMENSIONS.29 REMOVE EXISTING CASEWORK/MILLWORK & COUNTER (AS APPLICABLE)30 REMOVE EXISTING ELECTRICAL CHASE. ELECTRICAL EQUIPMENT TO REMAIN IN PLACE.31 REMOVE EXISTING SINK AND FAUCET. SEE MEP.32 REMOVE EXISTING WINDOW SHADES/BLINDS & ASSOCIATED HARDWARE AT THIS BANK OF WINDOWS.33 REMOVE INDICATED PORTION OF STONE TILE FLOORING AT FIREPLACE HEARTH. SALVAGE TILES FOR REUSE ELSWHERE. REFER TO NEW CONSTRUCTION DOCUMENTS FOR FULL EXTENT.35 REMOVE RECESSED WALL SAFE. SAVE FOR REUSE.36 REMOVE TACKSTRIPS, TACKBOARDS, CHALKBOARDS & ASSOCIATED HARDWARE ALONG THIS WALL.37 REMOVE AND SALVAGE EMPLOYEE MAIL SLOTS FOR RELOCATION DURING NEW CONSTRUCTION. REFER TO CONSTRUCTION PLANS FOR NEW LOCATION.38 EXISTING BENCH TO REMAIN.39 EXISTING CHALKBOARD TO REMAIN.40 REMOVE EXISTING PROJECTOR SCREEN (ABOVE) & ASSOCIATED HARDWARE.41 REMOVE OVERHEAD PROJECTOR IN THIS ROOM. SEE MEP. RETURN EQUIPMENT TO OWNER.42 REMOVE INDICATED EXTENT OF CAST IN PLACE CONCRETE WALL DOWN TO FOOTING. SEE STRUCTURAL FOR MORE INFO.43 NOT USED44 REMOVE GRILLE AT TOP OF FIN-TUBE RADIANT HEATER CABINET. EXISTING CABINET & RADIANT HEATING TO REMAIN.45 NOT USED46 NOT USED47 NOT USED48 NOT USED49 NOT USED50 NOT USED51 NOT USED52 EXISTING CASEWORK, TRIM, AND ASSOCIATED FIXTURES TO REMAIN53 REMOVE INDICATED AREA OF FLOOR/CEILING/ROOF ASSEMBLY IN PREPARATION FOR NEW HVAC CHASE. DO NOT OVERCUT. DO NOT CUT INTO EXISTING JOISTS. SEE MEP FOR MORE

INFO.54 REMOVE SOUTH EXTERIOR SHAFT WALL AT ELEVATOR DOWN TO FOOTING. SEE STRUCTURAL55 REMOVE EXISTING ELEVATOR PIT SLAB.56 REMOVE INDICATED EXTENT OF SLAB, CT FLOOR FINISH & EXISTING CONCRETE MOP SINK IN PREPARATION FOR NEW SANITARY SEWER CONNECTION; SEE MEP. SALVAGE CT FLOORING

FOR REUSE IN NEW CONSTRUCTION.

57 EXISTING STONE TILE FLOORING AT FIREPLACE TO REMAIN.58 REMOVE EXISTING EXTERIOR DOOR, WINDOW & FRAME ASSEMBLY INCLUDING ANY ASSOCIATED HARDWARE.59 REMOVE EXISTING WIRE MESH PARTITION ASSEMBLY INCLUDING INDICATED DOOR, FRAME, AND HANDRAILS.60 NOT USED61 NOT USED62 NOT USED63 NOT USED64 REMOVE EXISTING BIKE RACKS; SALVAGE FOR REINSTALLATION; SEE SITE PLAN65 REMOVE EXISTING CANOPY ROOF DRAIN AND RWL BACK TO MAIN AND CAP; SEE MEP66 REMOVE EXISTING CANOPY ROOF DRAIN AND RWL BACK TO EXTERIOR WALL. CONNECT NEW ROOF DRAIN TO EXISTING PIPING.67 EXISTING FLOORING IN THIS SPACE TO BE REMOVED BY OWNER.68 REMOVE APPROXIMATELY 40 SQ. FT OF EXISTING VCT FLOORING ADJACENT TO EXISTING ELEVATOR MACHINE ROOM IN PREPARATION FOR NEW INFILL VCT. ONLY REMOVE WHOLE TILES

AND SQAURE OFF AREA REMOVED TO MATCH PATTERN OF EXISTING VCT LAYOUT.69 REMOVE INDICATED AREA OF VCT FLOORING & SLAB IN PREPARATION FOR NEW SANITARY SEWER STUB-IN. REMOVE WHOLE TILES ONLY.70 REMOVE INFILL STUD WALL TO BOTTOM OF EXISTING SOFFIT ABOVE; EXISTING BULKHEAD & SOFFIT TO REMAIN; FIELD VERIFY HEIGHT OF SOFFIT.

N

No. Description Date1 ADDENDUM NO.1 3/20/2020

1