Upload
others
View
14
Download
1
Embed Size (px)
Citation preview
>> Regelungstechnik>> Gebäudemanagement>> Energiemanagement
DEOS AG - IHRE KOMPETENZ IN
>> Regelungstechnik>> Regelungstechnik>> Gebäudemanagement>> Gebäudemanagement>> Energiemanagement>> Energiemanagement
DEOS AG - IHRE KOMPETENZ INDEOS AG - IHRE KOMPETENZ IN
>> Gebäudemanagement
DEOS AG - IHRE KOMPETENZ IN
OPEN EMSController
The intelligence foryour building.
Save energy and increase comfort
Open DDC platform system
DDC product line for small and large-scale system projects
60% faster programming thanks to comprehensive libraries
DEOS AG - YOUR COMPETENCE IN
>> Building Automation>> Control Technology>> Energy Management
2
The OPEN EMS platform from DEOS AG allows you to lower your energy costs in buildings while simultaneously increasing comfort for building users.
The controller (DDC) OPEN EMS provides the central intelligence to accomplish this. It is designed asa native BACnet building controller (B-BC) for use in a wide range of areas in all types of buildings, including, for example, hotels, offi ce buildings, universities, museums and airports, etc.
The OPEN EMS controller therefore makes it easy for you to set up an intelligent room andbuilding automation controller at a central location or also remotely in your building interfaces. Thanks to the comprehensive functions and the vast fl exibility of the OPEN EMS, you can easily meet the complex requirements of your projects yourself.
Energy Management Station OPEN EMS – versatile operation.
OPEN EMS - powerful BACnet MS/TP and BAC-net IP controller
State-of-the-art HTML5 technology and mobile control via Android apps
System graphics are saved on the DDC controller
Professional safety concepts, such as hot standby DDC, safety ring bus, etc.
Practical development and in-house production – Made in Germany
Freely programmable DDC with comprehensive libraries for fast project planning
Forward-looking and powerful hardware and software for greater durability and increased investment security
Trend data is saved on the controller, even if there is no network connection
3
The OPEN EMS controller family uses the system openness of the entire DEOS OPEN EMS platform (IO modules, BMS, energy management, etc.) and is seamlessly integrated into the DEOS overall concept for intelligent buildings.
Controller familyOverview of your options.
Overview of your options
Your investment is protected by the powerful controller family (DDC) OPEN EMS with a wide range of interfaces and protocol connections.
Perfectly matched to the web-based BACnet building management systems(BMS) software OPENweb.
Ideally supplemented with the energy management software OPENenergy
Versatile with more than 30 diff erent OPEN EMS controllers, which enable precision solutions
TOP ProductPowerful
Compact controllerCost-eff ective
1) Please refer to the DEOS product catalog for the exact certifi cations for the DDC.
2) In the respective C2 variant. Please refer to the DEOS product catalog for all other product specifi cations.
OPEN EMS DDC types 4100 EMS 3100 EMS 810 EMS 710 EMS 600 EMS 500 EMS 600 EMSbasic24
Certificates CE, VDE, BACnet, WSPCert, BTL, AMEV B, Fraport, TÜV Süd, CSA 1)
Native BACnet MS/TP and IP ∕ ∕ ∕
Number of BACnet objects 4000 ∕ 1000 ∕ 250 ∕ 250
Graphic operation OPENview optional optional optional including
Number of DEOS IO modulesconnectable via CAN bus
99 (variant C2: up to198) 0 / 5 / 12 / 32 0 / 5 0
HSB ring and hot standby DDC 2) ∕ ∕ ∕
Number of in- and outputs ∕ ∕ 32 with & without manual control 24
DALI variant ∕ up to 4 interfaces / 256 adr. ∕
MODBUS up to 1000 DP up to 50 DP
M-Bus counters per integratedinterface
∕ up to 120, via 2 interfaces ∕
M-Bus (data points) per COM up to 250 DP up to 10 DP
KNX (EIB), optional IP up to 1000 up to 50
4
The new product version based on the OPEN 600 EMS (DDC) is a cost-eff ective controller designed for small HVAC systems. This DDC is also the ideal choice for use as a BACnet single room unit. The controller features 24 integrated digital and analog inputs and outputs and an ideal economical de-sign for these applications.
Thanks to the communication via BACnet IP, this controller is the perfect choice for use in both existingbuildings and properties as well as in new projects.
The secure remote access and remote monitoring via the integrated web server make it easy to ope-rate HVAC systems and individual rooms. The representations are rendered in the accustomed FULL HD resolution.
Powerful open system solutionBACnet compact controller OPEN 600 EMS basic24.
For small HVAC systems as a stand-alone as well as an integrated controller and single room controller
Cost-eff ective BACnet compact controllerwith analog and digital IOs
Includes full HD graphic HTML5 web server with BMS functions
Programming is up to 60% faster via projectplanning software and program libraries
Ideal for existing buildings andproperties as well as in new projects
BTL-listed (B-BC profi le) as well as AMEV attestation with (profi le B)
OPEN 600 EMS basic24Secure remote accessvia web browser
For small HVAC systems andBACnet single room units
BACnetMODBUSKNXM-bus
24 onboard integrated inputs and outputs BACnet IP and MS/TP support Up to 250 BACnet objects Protocols: BACnet, M-Bus, MODBUS, KNX, ... Interfaces: 2xRJ45, RS232, RS485 Integrated 2nd Ethernet port for easy serial
wiring (daisy chain) Freely configurable status LEDs (red/green) SMS and e-mail dispatch directly from controller Documentation directly on the controller
Technical highlights
8 Analog inputs 8 Digital inputs 4 Analog outputs 4 Digital outputs
OPEN 600 EMS basic24
DEOS HOTEL
Welcome
5
The SRU can be used for a wide range of applications. It is suitable for all types of HVAC controllers,ranging from simple heater controllers and fan coil units through to heating and cooling cascades.
You can connect bus-capable DEOS proprietary OPEN system control units as well asdevices from other manufacturers to the OPEN SRUs.
The SRU is programmed via the standardized DEOS project planning tool - the FUP XL.This provides the experienced programmer with the entire DEOS development environmentalong with all the necessary libraries.
Intelligent single room unitSRU Single Room Unit.
Freely programmable as a native BACnet controller
2 Digital high-current outputs
Integrated BACnet MS/TP;optional KNX-/MODBUS interfaces
Direct connection of sensors
*Of which four are 230V power outputs (normally open contact relays)
8 Universal inputs, 4 universal outputsand 4 digital outputs
Project planning made easy
Eliminate time-consuming routine work with the OPENproject confi guration and programming tool for object-based project planning based on BAC-net.
OPENproject enables the comprehensive and fast confi guration with the following programming op-tions of the OPEN EMS for all the SRUs for all func-tional modules throughout the entire building:you can control the temperature, ventilation, humi-dity in the heating, ventilation and air-conditioning system as well as the lighting, blinds and sockets
Straight forward bulk parameterization with OPENproject – that saves valuable time and increases the programming quality.
Type Number of IOs
SRU 16 IOs (8 inputs and 8 outputs) SRU+4DO 20 IOs (8 inputs and 12 outputs)SRU+4R2T 22 IOs (8 inputs and 14 outputs *)SRU+KNX same as SRU with 16 IOs + 50 objectsSRU+MODBUS same as SRU with 16 IOs + 50 data points
6
Components of the fl exible OPEN EMS platform also include the OPEN IO modules, which are currentlyavailable in 13 diff erent customized versions. Whether you need an analog or digital module, an IO combination module or a pure input and output module, all your requirements are covered. You will fi nd the right and most cost-eff ective DEOS IO module for your project.
The DEOS IO modules are connected to the OPEN EMS controller via the very durable and stable CAN-bus (Controller Area Network); the most common bus system for networking control units, e.g. in vehicle manufacturing. This bus system can accommodate up to 99 DEOS IO modules per line, which ensures the effi ciency and investment security for pending system expansions, etc.
+H off ers manual operation (LVB) via pushbutton.T and R indicates the transistor and relay variants.
Practical IO modulesFlexible connection in the fi eld.
CAN bus communication with up to 1 Mbit/s for a length of up to 5km
Convenient on-site manual operation (LVB)
Models available for wall and DIN-rail mounting
24-bit AD converters on digital IO modules, either with transistors or relay outputs
IO modules feature LED status displays
According to EN ISO 16484-2:2003 and VDI 3814
Manual operation via pushbutton on the modules provides the clever remote reset option via BMS software (OPENweb & OPENview). In case service is required, the option for setting the output voltage via pushbutton is helpful.
Practical advantage
Portfolio overview of the OPEN EMS IO modules
IN OUT Types
Digital input and output modules
16 -/- DI168 8 DI8DO8T
-/- 8 DO8T, DO8R or +H
IN OUT Types
Analoginput and output modules
8 -/- AI88 4 AI8AO4 or +H
-/- 4 AO4 or +H
7
System integration made easy – the technical building equipment components were consolidated into an overall system, enabling easy and secure operation and control of the room and building automation.
OPEN EMS uses standard communication protocols and interfaces, ensuring reliable and powerful building automation.
A number of standardized interfaces and protocols are available:
System connectionNumerous easy connection options.
Up to 12 diff erent bus protocols can run on a controller simultaneously
Cost-saving system advantages, e.g. with an integrated M-Bus level converter
Minimized cabling requirements and improved service handling thanks to the integrated 2nd port Ethernet switch
Cost-effi cient deployment: fewer DEOS controllers in your project
Flexible licensing models according to the number of data points
Simply contact us if you encounter non-standardized communication interfaces in your project. We are also happy to help you with the connection or successful implementation.
Flexible expandable controllers
8
Security considerations in state-of-the-art building automation are taking on increasingimportance and also includes other security-relevant areas. With your OPEN EMS platform, DEOS AG therefore off ers maximum security in your building network through the following solutions, etc.
Maximum securityOPEN EMS securely networked in your building.
Maximum security in building automation thanks to the best combination:redundant controller and safety ring bus.
Practical advantage
1
2
Safety ring bus (HSB)
Hot standby controller (redundancy)
CAN-HSB (high safety ring bus) is the next step of the worldwide approved CAN-bus.
DEOS IO modules at the fi eld level are networked together via a CAN-bus ring topology.
Advantage: if the ring is interrupted, the connected fi eld devices can still be controlled from the other ring side
Two redundant OPEN EMS controllers are available to increase operational safety
The fi rst (primary) controller is normally used for the control tasks
A secondary controller is in standby mode
If the primary controller fails, the secondary controller performs the control functions fully automatically
Normal operation
Fault
Normal operation
Fault
9
OPENweb
OPENdynamics
Cloud Solutions
OPENenergy
OPEN EMS
Comprehensive and integratedThe perfect solutions for your building.
Optimum – perfectly matched componentsFast system response times between control elements and DDC
Certifi ed – we comply with standards and pass voluntary testsSuch as BACnet, BTL, WSPCert, AMEV B, CE, CSA as well as the FRAPORT and ESPA-X voluntary tests
Innovative – customer requirements drive product innovationse.g. the hot standby controller, CAN HSB safety bus, etc.
Future-proof – easy and extensive third-party system connectionsProtocols and interfaces are available for expansions: KNX, DALI, MODBUS, etc.
Web-based BACnet BMS Access via Android phone, tablet or PC
Energy Management Customized reports
Enhanced comfort Cost transparency Patented control
Freely programmable BACnet controller Easy system integration
Central BMS cloud solutions Secure site networking Create effi cient advantages
Leading – one of the most technologically advanced BACnet solutions worldwideThe forward-looking pioneer of the BACnet protocol
50 years of building technology at the highest levels makeDEOS AG an internationally successful company today. We develop complete intelligent end-to-end system solu-tions and services for building automation.YEARS
OF INNOVATION
Effi ciency solutions with increased comfort
Patentiert durch das deutsche Patent- undMarkenamtPatent Nr.: DE 10 2009 016 418Patentierter DEOS AG Regelalgorithmusfür Klima- und Lüftungsanlagen
10
System topologyDEOS product at a glance.
11
OPEN EMS - Save energy and increase comfort the easy way. increase comfort the easy way.
AddressDEOS AGBirkenallee 7648432 RheineGermany
Find more information aboutyour local distributor on ourwebsite www.deos-ag.com.
Contact +49 5971 91133-0 +49 5971 [email protected]
DEOS AG is a technology leader and innovator for building automation. We have been developing and distributing intelligent and comprehensive Digital Energy Optimization Systems for building automation that strike the perfect balance between comfort, energy effi ciency and cost transparency for more than 50 years.