25
Operating Nitrox System Operating Nitrox System s 1 Presented by Nuvair

Operating Nitrox Membrane Systems

  • Upload
    kana

  • View
    38

  • Download
    0

Embed Size (px)

DESCRIPTION

Operating Nitrox Membrane Systems. Presented by Nuvair. Membrane systems produce nitrox efficiently. Compressed air flows through the membrane Nitrogen rich gas is expelled Oxygen rich gas is produced. Components of the membrane system. Nitrogen release. Permeate O2 Rich Gas. Membrane. - PowerPoint PPT Presentation

Citation preview

Page 1: Operating Nitrox Membrane Systems

Operating Nitrox SystemsOperating Nitrox Systems 11

Presented by Nuvair

Page 2: Operating Nitrox Membrane Systems

Operating Nitrox Systems 2

Membrane systems produce nitrox efficiently

• Compressed air flows through the membrane• Nitrogen rich gas is expelled• Oxygen rich gas is produced

Page 3: Operating Nitrox Membrane Systems

Operating Nitrox Systems 3

Components of the membrane system

Intake hose

Membrane

Air FilterMixing Tube

Permeate O2Rich Gas

Nitrogenrelease

Page 4: Operating Nitrox Membrane Systems

Operating Nitrox Systems 4

Components of the membrane system

Heater

Analyzer

Filters

Regulator

HeaterThermostat

Page 5: Operating Nitrox Membrane Systems

Operating Nitrox Systems 5

System Specifications

• Membrane temperature: 110 degrees F or 43 degrees C• Operating pressure: 80-170 p.s.i., 6-12 bar• Max input pressure: 300 p.s.i. or 21 bar• Air supply quality: LP Grade D, HP Grade E• Nitrox Range: 24% - 40%

Page 6: Operating Nitrox Membrane Systems

Operating Nitrox Systems 6

The membrane is incorporated in these systems

For dive operators who own HP compressors For dive operators

who want a complete nitrox solution

Page 7: Operating Nitrox Membrane Systems

Operating Nitrox Systems 7

Rotary Screw System Operation

• System is for dive operators who already own HP compressor

Page 8: Operating Nitrox Membrane Systems

Operating Nitrox Systems 8

Rotary Screw System Components

Control Panel

PowerSwitch

Inline Permeate O2 Analyzer Membrane

Nitrox outTo HP

On/OffSwitch

Drier on/off switch

Page 9: Operating Nitrox Membrane Systems

Operating Nitrox Systems 9

Rotary Screw System Components

Operation Gauge

Adjust O2 %

HP Intake

Nitrox outTo HP

Page 10: Operating Nitrox Membrane Systems

Operating Nitrox Systems 10

Rotary System Rear Components

Heater ThermostatControl

Pressure switch

Waste air

Page 11: Operating Nitrox Membrane Systems

Operating Nitrox Systems 11

Easy operation

• Always read the manual first!

• Steps vary depending on installation

• Check oil level & filters first

• Turn on drier

Page 12: Operating Nitrox Membrane Systems

Operating Nitrox Systems 12

Calibrate the fill O2 analyzer

Page 13: Operating Nitrox Membrane Systems

Operating Nitrox Systems 13

Follow the steps in the manual

• Turn on HP compressor

• Adjust fill whip allowing air to escape

• Calibrate permeate O2 analyzer

• Turn on LP compressor

Page 14: Operating Nitrox Membrane Systems

Operating Nitrox Systems 14

Follow all safety precautions

• Adjust input pressure to over 80 p.s.i. (5.5 bar)

• Verify thermostat operation

• Increase or decrease pressure to set final O2%

Page 15: Operating Nitrox Membrane Systems

Operating Nitrox Systems 15

Final adjustments• Fill O2 analyzer should

read same as inline O2 analyzer

• You are ready to pump nitrox!

Page 16: Operating Nitrox Membrane Systems

Operating Nitrox Systems 16

Always test the nitrox in the cylinder with an independent analyzer!

• Have the customer analyze the gas and sign for it

Page 17: Operating Nitrox Membrane Systems

Operating Nitrox Systems 17

Components of the Voyager (nitrox in a box!)

Fill O2Analyzer

HP FilterCannister

Fill pressuregauge

Permeate O2Analyzer

Dial-A-PressureControl

LP Filters

Page 18: Operating Nitrox Membrane Systems

Operating Nitrox Systems 18

Additional Voyager components…

HP Controls

LP OilLevel

HP OilLevel

Feed aircontrol

LP Gauges

TemperatureGauges

HeaterThermostat

Page 19: Operating Nitrox Membrane Systems

Operating Nitrox Systems 19

Using the Voyager

• Always read the manual first!

• Check oil level & filters

• Check LP feed valve is off

• Start HP compressor

Page 20: Operating Nitrox Membrane Systems

Operating Nitrox Systems 20

Using the Voyager• Open one fill whip -

adjust to hold 1500 p.s.i. (103 bar)

• Drain condensate• Calibrate analyzers

Page 21: Operating Nitrox Membrane Systems

Operating Nitrox Systems 21

Operation is simple!

• Adjust regulator initially for low pressure

• Turn on LP feed air valve

• Increase regulator pressure to 80-160 p.s.i. (5.5-11 bar)

Page 22: Operating Nitrox Membrane Systems

Operating Nitrox Systems 22

Operation is simple!

• Wait for O2% to stabilize on permeate analyzer

• Adjust regulated input pressure

• Wait for correct nitrox % on the fill O2 analyzer

• When O2% is correct, attach whip & fill tank!

Page 23: Operating Nitrox Membrane Systems

Operating Nitrox Systems 23

Always test the nitrox in the cylinder with an independent analyzer!

• Have the customer analyze the gas and sign for it

Page 24: Operating Nitrox Membrane Systems

Operating Nitrox Systems 24

Operation of membrane systems is easy!

• Membrane systems provide accurate nitrox mixtures.

• Membrane systems require the least amount of training.

• Membrane systems allow you to fill nitrox tanks at same rate as air tanks.

Page 25: Operating Nitrox Membrane Systems

Operating Nitrox Systems 25

Thank you for attending!