7
Operation and Maintenance Guide Pneumatic Turbine Fans Models Covered Model Number Description IMPA Number PTF300 Pneumatic driven fan, 300mm diameter 59.14.46 PTF400 Pneumatic driven fan, 400mm diameter 59.14.47 Read this manual carefully before installing, operating or servicing this equipment. It’s the responsibility of the employer to ensure this manual is read by the operator. Please preserve this manual. This document issued with Model No. Product Serial Number & are trademarks of Teryair Equipment Pvt. Ltd. PTF300 PTF400

Operation and Maintenance Guide Pneumatic … and Maintenance Guide Pneumatic Turbine Fans ... 6.2 Bar (90 Psi) ... air motor, turbine impeller, 4 bolts and 4

  • Upload
    hanhi

  • View
    232

  • Download
    2

Embed Size (px)

Citation preview

Page 1: Operation and Maintenance Guide Pneumatic … and Maintenance Guide Pneumatic Turbine Fans ... 6.2 Bar (90 Psi) ... air motor, turbine impeller, 4 bolts and 4

Operation and Maintenance Guide

Pneumatic Turbine Fans

Models Covered

Model Number Description IMPA Number

PTF300 Pneumatic driven fan, 300mm diameter 59.14.46 PTF400 Pneumatic driven fan, 400mm diameter 59.14.47

Read this manual carefully before installing, operating or servicing this equipment. It’s the

responsibility of the employer to ensure this manual is read by the operator. Please preserve this

manual.

This document issued with Model No.

Product Serial Number

& are trademarks of Teryair Equipment Pvt. Ltd.

PTF300 PTF400

Page 2: Operation and Maintenance Guide Pneumatic … and Maintenance Guide Pneumatic Turbine Fans ... 6.2 Bar (90 Psi) ... air motor, turbine impeller, 4 bolts and 4

FF-MM-310-REV-00

1

Air Turbine Fan Data

Model No

IMPA No.

Outlet Bore

diameter in mm

Air Flow Max.

Recommended Air Pressure

Air consumpt

ion

Recommended Air

Hose size

Air inlet and outlet

conn.

Weight in Kgs

PTF-300 59.14.46 300 130

m³/min 6.2 Bar (90 Psi)

40m³/hr 1/2" 1/2" NPT 32

PTF-400 59.14.47 400 210

m³/min 6.2 Bar (90 Psi)

50m³/hr 1/2" 1/2" NPT 42

Operating and Safety Precautions

Following symbols are used throughout this manual.

Warning: If not followed could cause personal injuries

Caution: If not followed could result in damage to equipment.

Warning

This manual must be read and the operating instructions carefully followed.

Warning

Operators under 18 not allowed to operate this equipment. Operators must be made familiar with the instructions in this manual before attempting to operate the equipment. Ensure that job site is clear of bystanders. Ensure that no loose items of clothing etc come in the vicinity of the fan.

Caution

Use only genuine Teryair or Teryair approved accessories.

Warning

Safety and protective clothing, eyewear, headgear, ear protection, gloves and footwear to be worn during operation of this equipment. The equipment must never be operated without the safety grill in place.

Warning

This equipment is not designed for use in an explosive environment.

Page 3: Operation and Maintenance Guide Pneumatic … and Maintenance Guide Pneumatic Turbine Fans ... 6.2 Bar (90 Psi) ... air motor, turbine impeller, 4 bolts and 4

FF-MM-310-REV-00

2

Intended and Prohibitive use

Intended Use

Teryair Air Driven Fans are ideal for releasing gases from tanks. They are compressed air operated driven. This product have wide applicability, and are ideal for expelling poisonous or other harmful gases from enclosed areas such as tanks, holds etc. Prohibitive use

Use by an underage, untrained or person who is under the influence of drugs or alcohol. Use with non genuine spare parts or accessories is prohibited

Operating instructions

Un packing

Identify all the components as below, contact your supplier if any parts are missing or damaged. This illustration is for identification only.

1. Factory assembled unit main product casing, air motor, turbine impeller, 4 bolts and 4 washers for handle fitment and 2 bolts and 2 washers for FRL fitment.

2. Handle, 2 nos. 3. FRL with mounting plate and hose 4. Adaptor 1 No.

Initial Assembly

� Invert the casing with air motor assembly (1) and fit the adaptor (4). � Now invert it back in original position and fit the FRL with mounting plate (3) on the casing. � Now loosen the hose clip by the flat screw driver on the open end of hose and fit the hose

on the nipple provided on the air motor. Tighten the hose clip afterwards. � Now fix the handles respectively with Bolt , spring washer and plain washer.

Page 4: Operation and Maintenance Guide Pneumatic … and Maintenance Guide Pneumatic Turbine Fans ... 6.2 Bar (90 Psi) ... air motor, turbine impeller, 4 bolts and 4

FF-MM-310-REV-00

3

Safety checks before and after operating the fan

� Check list before starting the fan � Check safety wear mentioned earlier in warnings. � Check Hose fittings are secure � Do not wear loose clothing etc around the fan. � Make sure the safety grill is secure on the fan. � Connect supply and exit hoses correctly. � Place the fan as desired and turn on air supply gradually.

Dimensional Data

PTF300 PTF400

Page 5: Operation and Maintenance Guide Pneumatic … and Maintenance Guide Pneumatic Turbine Fans ... 6.2 Bar (90 Psi) ... air motor, turbine impeller, 4 bolts and 4

FF-MM-310-REV-00

4

Disassembly and Re assembly

Shut off air supply and allow residual Pressure to bleed off.

Disconnect air supply from the FRL.

Disassembly of Fan assembly

a) Loose the hose clip (27) and remove the hose

(25) from the air motor.

b) Remove the FRL unit with its frame by un

screwing the fasteners on the casing.

c) Remove all the 4 bolts (19), spring washers (9)

and plain washers (12). It will loosen the Grill (12).

d) Now remove all 4 bolts (10), Spring washers (21)

and plain washers (22) and lift the fan assembly

with the motor frame (3) and Grill (6).

Disassembly of Fan a) Remove the bolt (16), spring washer (10) and washer

(17).

b) Now gently tap the fan from the shaft of motor. Secure

the key (17) and store it properly.

c) Now we can remove the grill (6).

d) Now remove bolt (26), Spring washer (15), Plain washer

(14) respectively.

e) Now tap the back of the motor frame (3) to disassemble

it from air motor assembly (29).

Page 6: Operation and Maintenance Guide Pneumatic … and Maintenance Guide Pneumatic Turbine Fans ... 6.2 Bar (90 Psi) ... air motor, turbine impeller, 4 bolts and 4

FF-MM-310-REV-00

5

Exploded View, PTF300/ PTF400

Page 7: Operation and Maintenance Guide Pneumatic … and Maintenance Guide Pneumatic Turbine Fans ... 6.2 Bar (90 Psi) ... air motor, turbine impeller, 4 bolts and 4

FF-MM-310-REV-00

6

Bill of Material, PTF300/ PTF400

Illu. No.

Part Number

Description PTF300 PTF400

1 801 10 01 Casing (300) 1 -

1 802 10 01 Casing (400) - 1

2 536 10 02 Adaptor (300) 1 -

2 801 10 02 Adaptor (400) - 1

3 536 10 03 Motor Frame (300) 1 -

3 537 10 03 Motor Frame (400) - 1

4 536 10 07 Turbine Fan (300) 1 -

4 537 10 04 Turbine Fan (300) - 1

5 536 21 01 Handle (300) 2 -

5 537 21 01 Handle (400) - 2

6 536 21 02 Griller (300) 1 -

6 537 21 02 Griller (400) - 1

7 536 31 01 Key 1 1

8 536 90 02 Allen Bolt 4 4

9 536 90 04 Spring Washer 10 10

10 536 90 05 Hex. Bolt 4 4

11 536 90 06 Hex. Bolt 1 1

12 536 90 07 Plain Washer 4 4

13 150 40 26 Allen Bolt 4 4

14 171 90 50 Plain Washer 3 3

15 199 90 47 Spring Washer 4 4

16 298 00 90 Plain Washer 6 6

17 311 90 11 Plain Washer 1 1

18 342 90 24 Plain Washer 4 4

19 500 90 41 Allen Bolt 6 6

20 591 90 05 Spring Washer 4 4

21 653 90 04 Spring Washer 4 4

22 671 90 06 Plain Washer 4 4

23 128 90 10B Hose Connector 2 2

24 801 19 01 Frl Mounting Plate 1 1

25 801 40 01 Hose 0.6Mtr 0.6Mtr

26 801 90 01 Hex. Bolt (300) 3 -

26 802 90 01 Hex. Bolt (400) - 3

27 69.40.69 Hose Clip 2 2

28 FRL12 Frl Unit Assembly 1 1

29 801 97 01 Air Motor Assembly 1 1

30 200 97 15 Silencer Assembly 1 1

31 022 40 21 Hex. Nut 2 2

32 35.13.54 400 PM Plug 1 1