16
www.protongroup.org OPERATIONS MANUAL FOR AIR HEATER PROTON EX Safety precautions Technical parameters Installation Construction and dimensions 05010416 Air Heater with the explosion proof AC-motor PROTON EX RU EN

OPERATIONS MANUAL FOR AIR HEATER PROTON EXbiomass.e2ecdn.co.uk/Downloads/PROTON_EX__05010416__EN.pdf · To provide proper wiring and application of the unit, please, ... must be additionally

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: OPERATIONS MANUAL FOR AIR HEATER PROTON EXbiomass.e2ecdn.co.uk/Downloads/PROTON_EX__05010416__EN.pdf · To provide proper wiring and application of the unit, please, ... must be additionally

www.protongroup.org

ВзрывозащищенныйАС-двигатель

PROTON EX

OPERATIONS MANUAL FOR AIR HEATER PROTON EX

Safety precautions

Technical parameters Installation

Construction and dimensions

05

01

04

16

Air Heater with theexplosion proof AC-motor

PROTON EX

RU

EN

Page 2: OPERATIONS MANUAL FOR AIR HEATER PROTON EXbiomass.e2ecdn.co.uk/Downloads/PROTON_EX__05010416__EN.pdf · To provide proper wiring and application of the unit, please, ... must be additionally

Operations manual for air heater with the explosion proof motor PROTON EX:

1. Introduction .............................................................................................................................................................2. Safety precautions ..............................................................................................................................................

3. General information ............................................................................................................................................

9. Control elements ................................................................................................................................................

3

4

54. Dimensions ............................................................................................................................................................. 65. Construction .......................................................................................................................................................... 76. Technical characteristics .................................................................................................................................. 8

119

12

7. Installation .............................................................................................................................................................8. Connection of heat medium ...........................................................................................................................

10. Wiring control elements ................................................................................................................................... 1311. Reference information ..................................................................................................................................... 14

2

CONTENTS

Page 3: OPERATIONS MANUAL FOR AIR HEATER PROTON EXbiomass.e2ecdn.co.uk/Downloads/PROTON_EX__05010416__EN.pdf · To provide proper wiring and application of the unit, please, ... must be additionally

1. INTRODUCTION

The company PROTON GROUP LLC thanks you for choosing air heaters PROTON.

3

Обращение

This manual is an integral part of the product and must always accompany it, and should be transferred to the user.

The user should strictly follow safety instructions while installing, using and servicing the unit.

The manufacturer disclaims any responsibility for damages caused by wrong installation and misuse of the unit.

The manufacturer disclaims any responsibility for damages done by people who didn’t study the manual.

The manufacturer preserves the right to introduce any amendments to the manual without prior notification.

The manufacturer preserves the right to alter the construction which doesn’t impact its functioning and basic technical parameters.

The air heater is intended only and exclusively to be installed and used for purposes which it has been designed. Any misuse or noncompliance with the manufacturer’s instructions may lead to property damages, personnel injuries or death. The user has to take measures to eliminate possibilities of misuse of the unit.

The access to the unit must be restricted for unauthorized and unqualified personnel. The appropriate training of the maintenance sta� should be provided.

To provide proper wiring and application of the unit, please, study this manual thoroughly before installation.

We recommend keeping the manual safe in order to address it during operation.

3

Page 4: OPERATIONS MANUAL FOR AIR HEATER PROTON EXbiomass.e2ecdn.co.uk/Downloads/PROTON_EX__05010416__EN.pdf · To provide proper wiring and application of the unit, please, ... must be additionally

2. SAFETY PRECAUTIONS

55

Обращение

Current network which feeds the unit’s motor and controls must be additionally protected by a fuse to prevent consequences of shunt fault.

Check compliance of parameters of the electrical supply network to the ones indicated on the unit’s rating plate before connecting to the power supply.

Check grounding. Prohibit the use of the unit without grounding as it may cause property damages, personnel injuries and death.

Check correctness of connections of the system, accordance of the heat medium parameters to the parameters indicated on the rating plate as well as leak proof of joints before filling in the heat medium.

Before any actions connected with the air heater, please, study this manual to provide safety.

Installation and connection of the equipment to pipelines and networks must be performed by qualified personnel only, having appropriate access.

During installation, start-up, repair and maintenance of the air heater follow the safety rules.

Use screws appropriate for the material which the base is made of.

While the air heater is operating under low temperatures, the user must provide protection of the water heat exchanger or use heat medium with special additives preventing copper corrosion.

-t

Avoid substances and impurities in the heat medium causing copper corrosion.

Install the unit on a firm base or surface, which can stand its weight filled with water.

4

Проверьте наличие заземления. Не допускается использование щита управления без заземления, это может привести к повреждению имущества, травмам и гибели персонала.

Во время монтажа, запуска, ремонта и обслуживания щита управления соблюдайте все правила и нормы безопасности.

To prevent defrosting of the air heater’s heat exchanger when circulation of the heat medium is stopped during a heating period under outdoor temperatures lower than 0°C, you need to drain the heat medium from the heat exchanger and blow it o� by compressed air.

NEW

Provide protection of a fan against overheat by connecting protection devices to contacts of fan temperature sensor.

Page 5: OPERATIONS MANUAL FOR AIR HEATER PROTON EXbiomass.e2ecdn.co.uk/Downloads/PROTON_EX__05010416__EN.pdf · To provide proper wiring and application of the unit, please, ... must be additionally

Обращение

5

It is designed to heat industrial premises and warehouses under conditions of extra explosion safety. This equipment is to be mounted in buildings with increased probability of explosion as a result of interaction with dangerous materials as well as because of some technological processes.

PROTON EX

Principle of operation

Model range

PROTON EX 30 – heating power 10-30 kWPROTON EX 50 – heating power 25-50 kWPROTON EX 70 – heating power 40-70 kW

Applications

Chemicals production premisesPaint and varnish industryFurniture production premisesOil- and gas processing factoriesWorkshops with installed vessels and containers of high pressurePremises of production of highly explosive substances

The air heater PROTON is an element of a heating system. It is designed for heating air and its even distribution in buildings. Its work is based on axial fan functioning, which charges the air and pass it through a copper-aluminum heat exchanger in which the heat medium (hot water) flows at certain temperature. Heated air is supplied into a room and is directed to the working area by directing louvers.

Explosion proofdesign

3. GENERAL INFORMATION

Outlet pipe

Inlet pipe

Page 6: OPERATIONS MANUAL FOR AIR HEATER PROTON EXbiomass.e2ecdn.co.uk/Downloads/PROTON_EX__05010416__EN.pdf · To provide proper wiring and application of the unit, please, ... must be additionally

Dimensions of the air heater PROTON EX

Fastening dimensions of the mounting console CM LX

6

4. DIMENSIONS

620

380

680

68

0

6,38,3

580

20

01

47

195

51

5

195

195

195

Page 7: OPERATIONS MANUAL FOR AIR HEATER PROTON EXbiomass.e2ecdn.co.uk/Downloads/PROTON_EX__05010416__EN.pdf · To provide proper wiring and application of the unit, please, ... must be additionally

5. CONSTRUCTION

Major components of the air heater PROTON EX

Casing

Fan

Heat exchanger

Directing louvers

A heat exchanger consists of copper tubes and aluminum lamellas pressed on them. It is equipped with copper pipes with threading connection (external thread 3/4”). Copper-aluminum heat exchanger is distinguished by high e�ciency, is not exposed to corrosion if you don’t use substances and impurities in the heat medium causing copper corrosion. Maximal parameters of heat medium supply are 130 °C/1,6 MPa.

Protection-proof axial fan of the air heater PROTON EX provides even air distribution on heat exchanger’s surface. The construction and material of the fan prevents sparks and local temperature increase in motor windings. Overheat protection is provided by a thermistor sensor, not a temperature sensor as for standard motors. The motor meets European requirements on explosion safety. Rated power supply of PROTON EX fans is 3~400 V/50 Hz. Motor protection rating is IP44 (EN60529), isolation class THCL155, protection class II2Gc ExeIIB T3. Operating temperature range is-20 °C to +40 °C.

Взрывозащищенный вентилятор PROTON EX обеспечивает равномерное распределение потока воздуха по всей поверхности теплообменника. Конструкция и материал вентилятора не допускают искрообразования и локального повышения температуры на обмотках двигателя. Защита от перегрева осуществляется за счет специального термисторного датчика, а не термоконтакта, как в стандартных двигателях. Вентилятор соответствует европейским нормам по взрывобезопасности. Номинальное питание вентиляторов в серии EX осуществляется от источника 3~400 В/50 Гц. Степень защиты двигателя IP44, класс изоляции – THCL155, класс защиты II2Gc ExeIIB T3. Диапазон температур во время работы составляет от -20 до +40 °C.

Metal casing is made of elements dyed by protection cover that provides long-time protection against corrosion and conforms with European quality and design standards.

7

Êîìïëåêò íàïðàâëÿþùèõ æàëþçè ñ èíäèâèäóàëüíîé ðåãóëèðîâêîé îáåñïå÷èâàåò íàïðàâëåíèå ñòðóè òåïëîãî âîçäóõà. Íàïðàâëÿþùèå æàëþçè èìåþò àýðîäèíàìè÷åñêèé ïðîôèëü, êîòîðûé ïîçâîëÿåò ïîëó÷èòü íèçêèé êîýôôèöèåíò ñîïðîòèâëåíèÿ âîçäóøíîãî ïîòîêà è, êàê ñëåäñòâèå, ìàêñèìàëüíóþ äàëüíîñòü ñòðóè òåïëîãî âîçäóõà.

They are made of steel and dyed by special paint, and provide minimal air resistance at the outlet from the air heater. Aesthetic look and high protection from corrosion guarantee durability and safety.

Page 8: OPERATIONS MANUAL FOR AIR HEATER PROTON EXbiomass.e2ecdn.co.uk/Downloads/PROTON_EX__05010416__EN.pdf · To provide proper wiring and application of the unit, please, ... must be additionally

Parameters according to the heat medium

8

EX 30

Parameters according to the heat medium EX 50

Parameters according to the heat medium EX 70

Number of heat exchanger rows

Airflow

Heating power

Air temperature increase

Max. temperature of heat medium

Max. working pressure

Max. warm air throw

Volume of water in heat exchanger

Diameter of connection pipes

Weight without heat medium

Supply voltage

Motor power

Rated current of motor

Noise level

Motor protection rating

m³/h

kW

°С

°С

MPa

m

dm³

inch

kg

V/Hz

W

dB

А

IP

R

General parameters

6. TECHNICAL CHARACTERISTICS

(m³/h) (kW) (kPa)

Pg Qw(°С)

Pp2 p(m³/h) (kW) (kPa)

Pg Qw(°С)

Pp2 p(m³/h) (kW) (kPa)

Pg Qw(°С)

Pp2 p(m³/h) (kW) (kPa)

Pg Qw(°С)

Pp2 p

Water 90/70 Water 80/60 Water 70/50 Water 60/40Parameters (°С) T /z Tp

(m³/h)

Qp

(°С)

Pp1

(m³/h) (kW) (kPa)

Pg Qw(°С)

Pp2 p(m³/h) (kW) (kPa)

Pg Qw(°С)

Pp2 p(m³/h) (kW) (kPa)

Pg Qw(°С)

Pp2 p(m³/h) (kW) (kPa)

Pg Qw(°С)

Pp2 p

Water 90/70 Water 80/60 Water 70/50 Water 60/40Parameters (°С) T /z Tp

(m³/h)

Qp

(°С)

Pp1

(m³/h) (kW) (kPa)

Pg Qw(°С)

Pp2 p(m³/h) (kW) (kPa)

Pg Qw(°С)

Pp2 p(m³/h) (kW) (kPa)

Pg Qw(°С)

Pp2 p(m³/h) (kW) (kPa)

Pg Qw(°С)

Pp2 p

Water 90/70 Water 80/60 Water 70/50 Water 60/40Parameters (°С) T /z Tp

(m³/h)

Qp

(°С)

Pp1

29.7

27.7

25.7

23.8

21.8

19.8

51.5

48.1

44.7

41.3

37.9

34.5

66.5

62.2

58.0

53.8

49.5

45.2

53.3

54.8

56.4

57.8

59.3

60.7

57.2

52.9

48.7

44.4

40.1

35.7

38.3

34.0

29.5

25.0

20.4

15.5

30.8

32.2

33.6

35.0

36.2

37.2

45.9

47.4

48.9

50.4

51.8

53.2

47.8

43.6

39.2

34.9

30.5

26.0

38.4

39.9

41.4

42.8

44.2

45.6

14.2

12.3

10.6

8.9

7.4

6.0

18.5

16.4

14.4

12.5

10.7

9.1

3.0

2.8

2.6

2.4

2.2

2.0

2.6

2.4

2.2

2.0

1.8

1.6

2.1

1.9

1.8

1.6

1.4

1.2

1.7

1.5

1.3

1.1

0.9

0.7

7.1

5.7

4.4

3.3

2.2

1.4

10.4

8.8

7.2

5.8

4.6

3.4

37.3

39.8

42.3

44.7

47.2

49.6

44.0

40.6

37.2

33.8

30.4

26.9

36.5

33.1

29.7

26.2

22.7

19.2

26.5

28.9

31.4

33.9

36.3

38.7

28.9

25.4

21.9

18.4

14.8

10.9

20.9

23.4

25.8

28.2

30.6

32.8

11.4

9.9

8.4

7.0

5.8

4.6

31.9

34.4

36.9

39.3

41.8

44.2

15.0

13.2

11.6

10.0

8.5

7.2

2.3

2.2

2.0

1.9

1.7

1.6

1.6

1.5

1.3

1.2

1.1

0.9

1.3

1.4

1.0

0.8

0.7

0.5

5.5

4.4

3.4

2.4

1.6

1.0

8.3

6.9

5.7

4.5

3.5

2.6

2.0

1.8

1.7

1.5

1.4

1.2

19.2

22.9

26.6

30.2

33.9

37.6

25.3

23.3

21.3

19.3

17.2

15.2

20.8

18.8

16.7

14.7

12.6

10.5

16.3

20.0

23.7

27.4

31.0

34.7

13.4

17.1

20.8

24.4

28.1

31.7

16.2

14.2

12.1

10.0

7.8

5.3

10.5

14.1

17.8

21.4

25.0

28.4

1.3

1.2

1.2

1.1

1.0

0.9

1.2

1.1

1.0

0.9

0.8

0.7

0.9

0.9

0.8

0.7

0.6

0.5

0.8

0.7

0.6

0.5

0.4

0.3

3.0

2.4

1.8

1.3

0.8

0.4

4.6

3.9

3.1

2.5

1.9

1.4

6.5

5.6

4.7

3.9

3.2

2.6

8.5

7.5

6.6

5.7

4.8

4.0

46

00

4 1

00

37

00

EX 30

4600

28

1.30

29.4

29.7

19.2

51.5

37.3

66.5

53.3

53

1

130

1.6

3/4

44

400/50

EX 50

4100

23

2.25

31.3

53

2

130

1.6

3/4

44

400/50

EX 70

3700

20

3.18

32.9

53

3

130

1.6

3/4

44

400/50

290

0.51

290

0.51

290

0.51

0

5

10

15

20

25

0

5

10

15

20

25

0

5

10

15

20

25

Pg

Qw

Pp2

p

Pp1 – air temperature at the inlet of the unit

– air temperature at the outlet of the unit

– heat power of the unit

– air consumptionPp Qp

Pz – water temperature at the inlet of the unit

– water temperature at the outlet of the unit

– water pressure drop in heat exchanger– water consumption

Page 9: OPERATIONS MANUAL FOR AIR HEATER PROTON EXbiomass.e2ecdn.co.uk/Downloads/PROTON_EX__05010416__EN.pdf · To provide proper wiring and application of the unit, please, ... must be additionally

Обращение

7. INSTALLATION

Installation of air heater PROTON EX

9

Ways of installation with mounting console

30

30

45

45

Distance from a wall, min. Mounting heightDistance of air stream

Distance from a ceiling, min. Mounting height

*directing louvers are installed under angle of 45 ** directing louvers are installed vertically*** directing louvers are installed symmetrically under

angle of 45

0,25 m3-8 m

up to 28 m

0,25 m4-12 m

28 m

3-8

m

*

4-1

2 m

**

15 m***

Wall mounting Ceiling mounting

8. INSTALLATION

Installation of air heater PROTON E 15

On a wall vertically or horizontally, and under angle of 30° or 45°.

Under a ceiling horizontally, or under angle of 30° or 45°.

Page 10: OPERATIONS MANUAL FOR AIR HEATER PROTON EXbiomass.e2ecdn.co.uk/Downloads/PROTON_EX__05010416__EN.pdf · To provide proper wiring and application of the unit, please, ... must be additionally

Обращение

Монтаж аппарата PROTON E 15

10

Recommended distances from walls and ceiling Manifold of a heat exchanger

Монтаж аппарата PROTON E 15Installation of a few units Recommendations of placing units

Noncompliance with the minimal distance (0,25 m) from a wall or ceiling will lead to wrong operation of the air heater which, in turn, will influence the useful life of the equipment.

When connecting the heat medium pay your attention that manifolds of the air heater must be fixed. For this use two keys: one – for fixing heat exchanger manifolds, the second – for connecting it to the system.

Examples of placing the equipment which provide even distribution of heat in a building are presented on the illustrations.

When mounting a few air heaters PROTON it is recommended to stick to the following distances between units: installation in one line – 5-9 m, installation opposite to each other – 27-35 m, installation one by one – 12-15 m.These distances are just recommendations. The installer should also take into account dimensions and shape of a building, its encumbering, and recommendations of specialists on a project.

5-9

m

12-15 m

27-35 m

7. INSTALLATION

min 0,25 m

min 0,25 m

min 0,5 m min 0,5 m

min 0,5 m

Page 11: OPERATIONS MANUAL FOR AIR HEATER PROTON EXbiomass.e2ecdn.co.uk/Downloads/PROTON_EX__05010416__EN.pdf · To provide proper wiring and application of the unit, please, ... must be additionally

Обращение

8. CONNECTION OF HEAT MEDIUM

9. CONNECTION OF HEAT MEDIUM

Switch panel or

Two-way valve with an actuator

PROTON ECO

Programmable controller

0,003

Piping unit heaters PROTON ЕСO

When connecting to the heating main pipes it is necessary to provide the following conditions:

Air heating units can be installed in closed heating systems with forced circulation with maximal temperature of the heat medium 105 °C and maximal pressure 1,6 MPa.

Installation of the air heater should be carried out referring to the minimal distances from walls, ceiling and floor.The air heater has to be completed with intercepting cocks on the inlet and outlet pipes.

1.

2.It is recommended to install a coarse filter on the inlet pipe.3.Provide at least one cock for heat medium drainage on the bottom point on the piping scheme of the air heater.

4.

Provide at least one air outtake on the upper point on the piping scheme of the air heater.5.The diameter of pipes should be selected in accordance with hydraulic calculations of the heat supply system.

6.

Heating tubes from the heating system pipe to the air heater must be installed with the pitch of 3° to the pipes the heat supply system.

7.

All cable trays for wiring a fan and two-way valve should be installed higher than pipes of the heating system.

8.

Installation must be done by technician/company who has appropriate permissions for performing such a type of work.

9.

11

PROTON EX

0,003

Piping unit heaters PROTON ЕX

Термодатчиквнешний

Inlet pipeline

Coarse filterDrain

Ball cock Ball cockAir outtake

Outlet pipeline

Piping unit heaters PROTON ЕСO

When connecting to the heating main pipes it is necessary to provide the following conditions:

Air heating units can be installed in closed heating systems with forced circulation with maximal temperature of the heat medium 130 °C and maximal pressure 1,6 MPa.

Installation of the air heater should be carried out referring to the minimal distances from walls, ceiling and floor.The air heater has to be completed with intercepting cocks on the inlet and outlet pipes.

1.

2.It is recommended to install a coarse filter on the inlet pipe.3.Provide at least one cock for heat medium drainage on the bottom point on the piping scheme of the air heater.

4.

Provide at least one air outtake on the upper point on the piping scheme of the air heater.5.The diameter of pipes should be selected in accordance with hydraulic calculations of the heat supply system.

6.

Heating tubes from the heating system pipe to the air heater must be installed with the pitch of 3° to the pipes the heat supply system.

7.

All cable trays for wiring a fan should be installed higher than pipes of the heating system.8.Installation must be done by technician/company who has appropriate permissions for performing such a type of work.

9.

Page 12: OPERATIONS MANUAL FOR AIR HEATER PROTON EXbiomass.e2ecdn.co.uk/Downloads/PROTON_EX__05010416__EN.pdf · To provide proper wiring and application of the unit, please, ... must be additionally

12

DS 2M Сontrol device

The device regulates three-phase motor of a fan by turning on/o� from an external thermostat and regulating rotations through recommutation of windings according to the scheme “delta” and “star” with help of a manual switch.

Possibility of smooth star-up (start - basing on “star”, operation - basing on “delta”).Possibility to regulate a group of air heaters.Simple and reliable construction.Dustproof and moisture resistance.Remote control of turn on/o� of motor.

STD EX Control board

Control board ECOMATIC STD EX is a board in which automatic switch, a thermistor relay of motor protection, and a “dry contact” of firefighting device are mounted. The board protects a motor from alarms, controls temperature of cable windings. It is a mandatory element for air heaters PROTON EX.

Three-phase construction.Control over motor temperature.Protection device against shunt fault.Connection to «dry contacts» of fireproof main.

STD EXЩит управления

Управление аппаратом сoвзрывозащищенным двигателем на базе щита управления:

380 В/50 Гц

STD EX

RD Термодатчиквнешний

NTC 65 External thermal sensor

RD Programmable thermostat

ECOMATIC PRO

ECOMATIC PRO is a control element with help of which advantages of heating and ventilation systems become more noticeable and perceivable as its use provide comfortable inside temperature and significant energy savings due to fast response of the system to changes

of climatic conditions in a room. Using PROTON PRO you increase equipment lifetime protecting it from functioning under alarm mode.

Programmable chrono-thermostat with high accuracy controls set temperature in a room, enables to program operation of air heaters PROTON in the modes “day-night” and “7-day calendar”.

Programmability of working cycles of the air heating system.Available and e�ective solution.Convenient interface and soft light.Ability to connect external temperature sensor.

High accuracy.Ability to connect a group of large buildings.Ability to use in explosive buildings.

The sensor is designed to fix temperature in a room and transfer data to a controller. The sensors have IP65 construction, that allows to apply them in industrial buildings (dusty, moist, explosive environments).

9. CONTROL ELEMENTS

Page 13: OPERATIONS MANUAL FOR AIR HEATER PROTON EXbiomass.e2ecdn.co.uk/Downloads/PROTON_EX__05010416__EN.pdf · To provide proper wiring and application of the unit, please, ... must be additionally

13

DS 2M

PETP TP V2V1U2U1W2 W1

Трехфазный АС-двигательв взрывоопасном исполнении

RDNTC65

11 10 9 8 7 6 5

3~400 В/50 Гц

N PE

B4 B4 B4

1L 2L 3L

PE PE1L 1U 2U1V 2V1W 2W2L 3L

N PE2 4 6

N PE1 3 5

N 2 3 41

STD EX

ППС

X1:4

X1:3

X1:2X1:1

Connect a «dry contact» of fireproof main.

Make the connection «dry contact» of fireproof main.

Обнспечьте подключение ППС — «сухой контакт» противопожарной централи.

While wiring, control the direction of fan rotation. It is necessary to swap two supply phases in case of its reverse direction of rotation.

It is necessary to remove jumpers between fan terminals while installing control device DS 2M.

It is necessary to provide motor protection against overheat, so wire TP contacts to a device, which controls power.

1 х RS 330

6 х E 15

2 х E 25, E 45, E 65

1 х E 35, E 55, E 75

3.1 Подключение однофазных трехскоростных АС-двигателей к блоку управления POWER BOX с пультом механическим RTS 10 (подключение несколькиих вентиляторов к одному каналу)

10. WIRING CONTROL ELEMENTS

Provide installation of a device protecting the motor from shunt fault (B on the scheme).

4

«Dry contact» of fire-proof main

DS 2M

PETP TP V2V1U2U1W2 W1

RD

NTC65

11 10 9 8 7 6 5

3~400 В/50 Гц

N PE

B4 B4 B4

1L 2L 3L

PE PE1L 1U 2U1V 2V1W 2W2L 3L

N PE2 4 6

N PE1 3 5

N 2 3 41

STD EX

X1:4

X1:3

X1:2X1:1

Three-phase AC-motor

Heated building

Page 14: OPERATIONS MANUAL FOR AIR HEATER PROTON EXbiomass.e2ecdn.co.uk/Downloads/PROTON_EX__05010416__EN.pdf · To provide proper wiring and application of the unit, please, ... must be additionally

11. REFERENCE INFORMATION11.1 Table of pressure calculation on a wire depending on its section

14

Data is presented as a reference. For calculations for actual projects address to specialists.

Section of current conducting core, mm

Material of the conductor – copper

Voltage, 220 V Voltage, 380 V

Current, A Power, kW Current, A Power, kW

1.52.54.0

6.010.016.025.035.050.070.095.0

120.0

4.15.98.3

10.115.418.725.329.738.547.357.266.0

10.516.519.826.4

49.559.475.995.7

118.8

145.2171.6

11.615.119.825.7

36.346.256.172.692.4

112.2132.0

4.46.17.9

13.2

18.7

29.7

50.6

36.3

22.0

44.0

11.0

19.027.038.046.070.085.0

115.0135.0175.0215.0260.0300.0

20.028.036.050.060.085.0

100.0135.0

165.0200.0230.0

19.023.030.039.055.070.0

85.0110.0

140.0170.0200.0

16.025.030.040.050.075.090.0

115.0145.0180.0220.0260.0

33.0

Material of the conductor – aluminum:

Material of the conductor – aluminum

2.54.06.0

10.016.0

25.035.050.0

70.095.0

120.0

2

Material of the conductor – copper:

Section of current conducting core, mm Voltage, 220 V Voltage, 380 V

Current, A Power, kW Current, A Power, kW

2

Page 15: OPERATIONS MANUAL FOR AIR HEATER PROTON EXbiomass.e2ecdn.co.uk/Downloads/PROTON_EX__05010416__EN.pdf · To provide proper wiring and application of the unit, please, ... must be additionally

11.2 Recommended diameters of pipes depending on power of equipment’s heat output

12. СПРАВВОЧНАЯ ИНФОРМАЦИЯ12.1 Таблица расчета нагрузки на провод в зависимости от его сечения

15

12. СПРАВВОЧНАЯ ИНФОРМАЦИЯ

kW Water consumption Inside diameter Type

15 kW

23 kW

39 kW

61 kW

96 kW

180 kW

20 mm

25 mm

32 mm

40 mm

50 mm

70 mm

3/4

1

1 14

1

2

2

0.6 m³/h

1.0 m³/h

1.6 m³/h

2.5 m³/h

4.0 m³/h

8.0 m³/h

12

12

11. REFERENCE INFORMATION

Data is presented as a reference. For calculations for actual projects address to specialists.

Page 16: OPERATIONS MANUAL FOR AIR HEATER PROTON EXbiomass.e2ecdn.co.uk/Downloads/PROTON_EX__05010416__EN.pdf · To provide proper wiring and application of the unit, please, ... must be additionally

PROTON GROUP LLC03680, Ukraine, Kyiv, 3, Nesterova str.Tel.: +380 (44) 537 0930Fax: +380 (44) 537 0903E-mail: [email protected]

www.protongroup.org

In case of any failures in operation of equipment address the authorized support centers of the Manufacturer.For information about support centers and procedure of claim submission contact Manufacturer’s service department:

Service department