10
Operator Interfaces (Selection Guide) 1233 Control Units Display Lights Display Units Safety Products Terminal Blocks Comm. Terminals AS-Interface Relays & Timers Sockets Circuit Protectors Power Supplies PLCs & SmartRelay Operator Interfaces Sensors Control Stations Explosion Protection References Flush Silhouette Operator Interface (small type) CC Pendant Teaching Pendant HG1F HG2S (color) HG2S (monochrome) HG1H HG1T 4.6 inches 5.7 inches 5.7 inches 4 inches 4 inches Analog touch panel enables exible screen layout. High-performance CPU ensures quick response in operation and display. Equipped with a 3-position enabling switch High-performance RISC CPU ensures stress-free quick response. CC switches and mechani- cal switches make up an ideal HMI equipment. CC switches and mechani- cal switches make up an ideal HMI equipment. IP65 water- and dust-proof structure Equipped with a 3-position enabling switch Mechanical switches such as key selector switches and pushbuttons can be installed. Equipped with a 3-position enabling switch Up to 4 mechanical switches such as pushbuttons can be installed. LCD with or without backlight available Compact size, lightweight 600g Monochrome STN Color STN Monochrome STN Monochrome STN Monochrome STN 111.4 × 38.4 118.2 × 89.4 118.2 × 89.4 95.96 × 31.96 300 × 100 320 × 240 320 × 240 192 × 64 Monochrome 256 colors Monochrome Monochrome Monochrome 37 characters × 12 lines 40 characters × 15 lines 40 characters × 15 lines 20 characters × 4 lines 12 characters × 4 lines 16 × 12 10 × 12 (CC switch type) 16 × 12 10 × 12 (CC switch type) 2 × 6 2 × 6 Y es Y es Y es Y es Y es Y es Y es Y es Y es Y es Y es Y es Y es Y es Y es Y es Y es Y es 4 points 4 points 3 points 3 points 24V DC 24V DC 24V DC 24V DC 24V DC 0 to 50°C 0 to 40°C 0 to 40°C 0 to 40°C 0 to 40°C IP65 (operator) IP65 (except CC switch and connector) IP65 (except CC switch and connector) IP54 (except cable connector) IP54 (except cable connector) 147 × 76 × 39.3 228 × 186 × 57 228 × 186 × 57 110 × 218.4 × 66.6 133 × 250 × 58.3 280g 1200g (except cable) 1200g (except cable) 400g (except cable) 600g (except cable) Y es Y es Y es Y es Y es WindO/I-NV2 WindO/I-NV2 WindO/I-NV2 WindO/I-NV2 WindE/T 1241 1249 1249 1255 1258

Operator Interfaces Selection Guide - flexitec.com.sgflexitec.com.sg/wp-content/uploads/2014/12/Touch-Screen-HG1F... · A1SJ71C24-R2, A1SJ71UC24-R2, A1SJ71C24-R4, A1SJ71UC24-R4 A2CCPUC24

  • Upload
    votu

  • View
    228

  • Download
    2

Embed Size (px)

Citation preview

Page 1: Operator Interfaces Selection Guide - flexitec.com.sgflexitec.com.sg/wp-content/uploads/2014/12/Touch-Screen-HG1F... · A1SJ71C24-R2, A1SJ71UC24-R2, A1SJ71C24-R4, A1SJ71UC24-R4 A2CCPUC24

Operator Interfaces (Selection Guide)

1233

ControlUnits

Display Lights

DisplayUnits

SafetyProducts

TerminalBlocks

Comm.Terminals

AS-Interface

Relays & Timers

Sockets

Circuit Protectors

Power Supplies

PLCs & SmartRelay

Operator Interfaces

Sensors

Control Stations

Explosion Protection

References

FlushSilhouette

Operator Interface (small type) CC Pendant Teaching Pendant

HG1F HG2S (color) HG2S (monochrome) HG1H HG1T

4.6 inches 5.7 inches 5.7 inches 4 inches 4 inches

• Analog touch panel enables flexible screen layout.

• High-performance CPU ensures quick response in operation and display.

• Equipped with a 3-position enabling switch

• High-performance RISC CPU ensures stress-free quick response.

• CC switches and mechani-cal switches make up an ideal HMI equipment.

• CC switches and mechani-cal switches make up an ideal HMI equipment.

• IP65 water- and dust-proof structure

• Equipped with a 3-position enabling switch

• Mechanical switches such as key selector switches and pushbuttons can be installed.

• Equipped with a 3-position enabling switch

• Up to 4 mechanical switches such as pushbuttons can be installed.

• LCD with or without backlight available

• Compact size, lightweight 600g

Monochrome STN Color STN Monochrome STN Monochrome STN Monochrome STN

111.4 × 38.4 118.2 × 89.4 118.2 × 89.4 — 95.96 × 31.96

300 × 100 320 × 240 320 × 240 — 192 × 64

Monochrome 256 colors Monochrome Monochrome Monochrome

37 characters × 12 lines 40 characters × 15 lines 40 characters × 15 lines 20 characters × 4 lines 12 characters × 4 lines

— 16 × 12 10 × 12 (CC switch type)

16 × 1210 × 12 (CC switch type) — —

— 2 × 6 2 × 6 — —

Yes Yes Yes Yes Yes

Yes — — Yes Yes

Yes — — Yes Yes

— Yes Yes — —

Yes Yes Yes Yes Yes

— — — — —

— — — — —

— — — — —

— 4 points 4 points — —

— 3 points 3 points — —

— — — — —

24V DC 24V DC 24V DC 24V DC 24V DC

0 to 50°C 0 to 40°C 0 to 40°C 0 to 40°C 0 to 40°C

IP65 (operator) IP65 (except CC switch and connector)

IP65 (except CC switch and connector) IP54 (except cable connector) IP54 (except cable connector)

147 × 76 × 39.3 228 × 186 × 57 228 × 186 × 57 110 × 218.4 × 66.6 133 × 250 × 58.3

280g 1200g (except cable) 1200g (except cable) 400g (except cable) 600g (except cable)

Yes Yes Yes Yes Yes

WindO/I-NV2 WindO/I-NV2 WindO/I-NV2 WindO/I-NV2 WindE/T

1241 1249 1249 1255 1258

Page 2: Operator Interfaces Selection Guide - flexitec.com.sgflexitec.com.sg/wp-content/uploads/2014/12/Touch-Screen-HG1F... · A1SJ71C24-R2, A1SJ71UC24-R2, A1SJ71C24-R4, A1SJ71UC24-R4 A2CCPUC24

HG

Series

Software (Wind O/I-NV2)

1234

Design tool WindO/I-NV2 assists you in programming your HG family O/Is.

Windows is a registered trademark of Microsoft Corporation, USA in the USA and other countries.

OS Windows 95 (OSR2 or later)/98/Me

RAM 64 MB minimumNT4.0/2000/XP/Vista

Hard Disk Space 150 MB minimum

Computer PC-AT compatible

Graphic SVGA (800

×

600) or higher

CPU Pentium 200 MHz or higher

Others Mouse, CD-ROM drive

Screen List Project Settings ListScreens can be duplicated and prop-erty can be changed easily. Projects can also be edited effectively. Import and export functions make it possible to replace devices, text, and shapes all at once. Exported CSV files can be edited using Excel.

Screen Preview ListScreens can be selected from the preview images and opened quickly.

Object ListInformation and figures of devices, condition types, and oper-ation conditions arranged on the screen can be confirmed. Properties can also be changed using the list.

The part selected in the object list is also reflected in the editing screen.

Work AreaThe project structure can be listed for easy viewing, and switched to the editing screen by one click.

System Requirements

Software

Page 3: Operator Interfaces Selection Guide - flexitec.com.sgflexitec.com.sg/wp-content/uploads/2014/12/Touch-Screen-HG1F... · A1SJ71C24-R2, A1SJ71UC24-R2, A1SJ71C24-R4, A1SJ71UC24-R4 A2CCPUC24

HG

Series

Software (Wind O/I-NV2)

1235

ControlUnits

Display Lights

DisplayUnits

SafetyProducts

TerminalBlocks

Comm.Terminals

AS-Interface

Relays & Timers

Sockets

Circuit Protectors

Power Supplies

PLCs & SmartRelay

Operator Interfaces

Sensors

Control Stations

Explosion Protection

References

FlushSilhouette

A maximum of 5 base screens can be overlapped, and sub screens can also be popped up, so screens can be arranged very effectively. Subscreens can be resized and made transparent to show the background using the superim-pose function as required. In addition, subscreens can be designed to have a move or close button.

Screen data can be imported from another project. Figures and scripts stored in library can be reused, so accumulated software properties can be used effectively. Image data of BMP, JPG, DXF, WMF, and ICO files as well as CAD data can also be used.

Legends for switches and lamps, and text massages used for the alarm func-tion can be managed in the text browser. Text property settings (font, text, color, and size) can be exported to a CSV format file, which can then be edited on Excel and imported back to the text browser, resulting in effective screen editing.

The device browser is used to list devices used in the project and also to replace used devices at once.

Operating conditions for switches and lamps, bit/word write, and screen switching can be programmed in the property settings for each part. Lamps can be easily set to turn on, turn off, and flash.

The HG can process various operations to reduce the task of the host. On the script editor, conditional equations and functions can be selected and input-ted from the function list. Syntax error check function is also available.

The standard key pad can be used for easy input-ting of numerals and text. In the pop-up display mode, the keyboard can be moved to the best position automatically.

Alarm log data can be listed during operation. Details of each data item can also be confirmed easily.

Bar graph, trend chart, pie chart, and meter can be displayed, and their colors, scales, and labels can be set easily. On the bar graph, the display color can be changed or flashed when an input overflow occurs.

Flexible Screen Display for Efficient Editing Possible to Reuse Data

Base Screen

Sub Screen

Text Browser for Text Data Management Device Browser for Listing Used Devices

Easy Programming of Parts Operating Conditions Script Function for Assisting the Host

Numeric Key Pad Settings Alarm Functions Various Graph Functions

Page 4: Operator Interfaces Selection Guide - flexitec.com.sgflexitec.com.sg/wp-content/uploads/2014/12/Touch-Screen-HG1F... · A1SJ71C24-R2, A1SJ71UC24-R2, A1SJ71C24-R4, A1SJ71UC24-R4 A2CCPUC24

HG1F/2F/3F/4F Operator Interfaces

1236

The HG series is equipped with most demanded features and functions.

Alarm logging display, alarm list display, and data logging display functions make it easy to view the production information and perform data collection and management.Alarm and data logging data can be saved on a CF card in a CSV file format, which can be edited on a PC. In addition, the current screen on the HG can be printed out or saved in a BMP file format.

Using the web browser on a PC or PDA, machine operating sta-tuses can be monitored and CF card data can be collected to the PC through an Ethernet network. Data can be collected from remote areas.

Record Viewer

Using utility software Record Viewer, alarm and log data stored in the HG can be uploaded through the maintenance communication and displayed on the PC.

After downloading a created project to the HG, actual operation can be confirmed while editing the data. Simulation mode makes it pos-sible to debug the project while confirming the HG operation without the need for connection to the host.

Preset values of the machine (positioning, work piece dimensions, etc.) can be stored on the internal memory of the HG. Using the stored preset values (recipe data), the machine can be initialized easily. The recipe data can be stored on the CF card and edited on a PC.(Available on HG models with CF card slot.)

Powerful Functions for Production Data Logging and Management

Alarm Logging and Data Logging

Logging Data

Alarm Log Data

CF CardPC

Monitor and Data Logging through Ethernet View Logged Data on a PC

Ethernet

LAN

LAN

PC or PDA withweb browser

HG3F/4F

Host

Record Viewer Screen Upload and View Logging Data

Initialize Logging Data

PC

HG1F/2F/3F/4FHG2S

Speeding Production System Start-up

Debugging Function Recipe Function

HG1F/2F/3F/4FHG2S

Host

PC

Screen Monitor Window

HG2F/3F/4F

CF Card

PLC

Model CDevice Data

D200 10

D201 11

D202 40

D203 20

15

Device Data

D200 8

D201 12

D202 30

D203 16

10

Model B

Recipe Data

Device Data

D200 10

D201 14

D202 32

D203 18

Model A

...

Features

Page 5: Operator Interfaces Selection Guide - flexitec.com.sgflexitec.com.sg/wp-content/uploads/2014/12/Touch-Screen-HG1F... · A1SJ71C24-R2, A1SJ71UC24-R2, A1SJ71C24-R4, A1SJ71UC24-R4 A2CCPUC24

HG1F/2F/3F/4F Operator Interfaces

1237

ControlUnits

Display Lights

DisplayUnits

SafetyProducts

TerminalBlocks

Comm.Terminals

AS-Interface

Relays & Timers

Sockets

Circuit Protectors

Power Supplies

PLCs & SmartRelay

Operator Interfaces

Sensors

Control Stations

Explosion Protection

References

FlushSilhouette

.

The text group selection function enables to make a selection from a maximum of 16 languages by changing the assigned device value, even during operation.

Applicable Languages:

Western European languages (English, German, French, Italian, Spanish, Dutch, Norwegian, Danish, Finnish, Irish, etc.)Central European languages (Czech, Hungarian, Romanian, Croat-ian, Slovene, Polish, and Slavic)

Fonts used in Windows can be displayed on the HG screens, mak-ing it possible to design the attractive screen layout.

In the O/I link communication network, the screen display data can be downloaded to multiple slaves at once.

The HG models with the Ethernet capability can upload and down-loaded the screen display data through the Ethernet.

The screen display data can be downloaded and uploaded using the CF card without the need of a PC. The CF card can store multi-ple pieces of project data.

In the network where the HG is connected to an IDEC PLC using the computer link communication system and the PC is connected to the HG using the maintenance cable, the PC can exchange data with the PLC using WindLDR.

The screen display data can be downloaded and uploaded through the USB port on a computer.

Multilingual Capabilities for Global Applications

Easy Selection of Multiple Languages Compatible with Windows Fonts

Speeding Production System Start-up

Simultaneous Download through O/I Link Maintenance through Ethernet

HG1F/2F/3F/4F/2S

O/I Link

MasterPC

Slave Slave

Host

Ethernet

PC

HG3F/4F

Download from CF Card PLC Data Exchange through the HG Unit

CF CardHG2F/3F/4F

HG1F/2F/3F/4FHG2S

IDEC PLCMicroSmartMicro3COpenNet Controller

WindLDRPC

WindO/I-NV2

USB Port on HG2FDownload Service

Latest versions of WindO/I-NV2, host interface driver,and user’s manual can be downloaded from the IDECweb site. Since the system program for the HG canalso be downloaded from WindO/I-NV2, your HGseries devices can be updated to use the latest func-tionality.

http://www.idec.com/Products/ENG/Software/SoftwareDownloads.html

After installing WindO/I-NV2, the download page can beopened from the Windows start menu.

HG2FPC

USB

Page 6: Operator Interfaces Selection Guide - flexitec.com.sgflexitec.com.sg/wp-content/uploads/2014/12/Touch-Screen-HG1F... · A1SJ71C24-R2, A1SJ71UC24-R2, A1SJ71C24-R4, A1SJ71UC24-R4 A2CCPUC24

HG1F/2F/3F/4F Operator Interfaces

1238

Applicable PLCs

Manu-facturer Series

Applicable System

(CPU Module)Link Unit

IDEC

FA-3S

PF3S-CP12, PF3S-CP13

PF3S-SIF2, PF3S-SIF4, PF2-CLA

PF3S-CP11, PF3S-CP11T PF2-CLA

FA-2J PF2J-CPU1OpenNet Controller

FC3A-CP2Not used (connect to CPU module)FC4A-SX5ES1E

MicroSmart

FC4A-C10R2, FC4A-C10R2C

Not used (connect to CPU module)FC4A-SX5ES1E

FC4A-C16R2, FC4A-C16R2C,FC4A-C24R2, FC4A-C24R2C

Not used (connect to CPU module)FC4A-PC1, FC4A-PC3,FC4A-SX5ES1E

FC4A-D20K3, FC4A-D20S3,FC4A-D20RK1, FC4A-D20RS1,FC4A-D40K3, FC4A-D40S3

Not used (connect to CPU module)FC4A-HPC1, FC4A-HPC3,FC4A-HPH1 + FC4A-PC1,FC4A-HPH1 + FC4A-PC3,FC4A-SX5ES1E

MicroSmartPentra

FC5A-C10R2, FC5A-C10R2C,FC5A-C16R2, FC5A-C16R2C,FC5A-C24R2, FC5A-C24R2C

Not used (connect to CPU module)

FC4A-PC1, FC4A-PC3,FC5A-SIF2FC4A-SX5ES1E

FC5A-D16RK1, FC5A-D16RS1,FC5A-D32K3, FC5A-D32S3

Not used (connect to CPU module)FC4A-HPC1, FC4A-HPC3,FC4A-HPH1 + FC4A-PC1,FC4A-HPH1 + FC4A-PC3,FC5A-SIF2FC4A-SX5ES1J

Mitsubishi

MELSEC-A

A1N, A2N, A3NAJ71C24, AJ71C24-S3/-S6/-S8, AJ71UC24

A1SH-S1A1SJ71C24-R2, A1SJ71UC24-R2, A1SJ71C24-R4, A1SJ71UC24-R4

A2CCPUC24 Not used (connect to CPU module)A0J2, A0J2H A0J2-C214-S1A2A, A3A, A2U, A3U, A4U

AJ71C24-S6/-S8, AJ71UC24

A2N Not used (connect to CPU module)A1SJH, A1SH, A2SH, A2C, A0J2H

Not used (connect to CPU module)

A2A, A3A, A2US, A2USH

Not used (connect to CPU module)

A2U, A1SH-S1 Not used (connect to CPU module)

MELSEC-QnA

Q4ACPUQ4ARCPUQ3ACPUQ2ACPU-S1Q2ACPU

AJ71QC24N-R2AJ71QC24NAJ71QC24N-R4AJ71QE71N3-TAJ71QE71N-B2AJ71QE71N-B5

Q2ASHCPU-S1Q2ASHCPUQ2ASCPU-S1Q2ASCPU

A1SJ71QC24N-R2A1SJ71QC24NA1SJ71QE71N3-TA1SJ71QE71N-B2A1SJ71QE71N-B5

MELSEC-Q

Q00CPU, Q01CPU Not used (connect to CPU module)Q02CPU, Q02HCPU Q06HCPU,Q12PHCPU,Q25HCPU

QJ71C24, QJ71C24N, QJ71C24N-R2

Q00JCPU, Q00CPU, Q01CPU, Q02CPU, Q02HCPU, Q06HCPU, Q12HCPU, Q25HCPU

QJ71E71-100QJ71E71-B5QJ71E71-B2

Q02CPU, Q02CPU-A mode

Not used (connect to CPU module)

MELSEC-FX

FX0, FX0N, FX1, FX2, FX2C, FX0S, FX1S

Not used (connect to CPU module)

FX2N, FX2NC, FX1N, FX1NC

Not used (connect to CPU module)FX2NC-232ADP

FX2N FX2N-232-BD, FX2N-422-BD FX1N FX1N-232-BD, FX1N-422-BDFX3UC Not used (connect to CPU module)

OMRON

SYSMAC-C

C500, C500F, C1000H, C2000, C2000H

C120-LK201-V1, C120-LK202-V1, C500-LK201-V1, C500-LK203

C1000HF C500-LK203C200HS C200H-LK201, C200H-LK202

C200HE, C200HG, C200HX

C200H-LK201, C200H-LK202,C200HW-COM02/COM04/COM05/COM06, C200HW-COM03/COM06

C120, C120F C120-LK201-V1, C120-LK202-V1C20H, C28H, C40H, C60H

Not used (connect to CPU module)

CQM1H, C200HS-CPU21/23/31/33

Not used (connect to CPU module)

C200HE-CPU42, C200HG-CPU43/63, C200HX-CPU44/64

Not used (connect to CPU module)

CPM1, CPM1A, CPM2A

CPM1-CIF01, CPM1-CIF11

CPM2A Not used (connect to CPU module)

SYSMAC-CS1CS1G, CS1H Not used (connect to CPU module)CS1G, CS1H CS1W-SCB41 (Port 1) (Port 2)

SYSMAC-CJ1M CJ1M Not used (connect to CPU module)

Allen-Bradley

PLC-5

All PLC-5 models compatible with 1770-KF2

1770-KF2

All PLC-5 models Not used (connect to CPU module)SLC-500 (Half Duplex)

SLC5/03, SLC5/04

Not used (connect to CPU module)

Micro Logix (Full Duplex)

Micro Logix 1000,Micro Logix 1100,Micro Logix 1200,Micro Logix 1500

Not used (connect to CPU module)

ControlLogixControlLogix 5500ControlLogix 5555

Not used (connect to CPU module)1756-ENBT

CompactLogix1768 CompactLogix1769 CompactLogix

Not used (connect to CPU module)

FlexLogic1794-L331794-L34

Not used (connect to CPU module)

PLC-5PLC-5 1756-ENBTPLC-5E Not used (connect to CPU module)

SLC 500

SLC5/05SLC5/03SLC5/04SLC5/05

1761-NET-ENI

MicroLogix

MicroLogix 1000MicroLogix 1100MicroLogix 1200MicroLogix 1500

1761-NET-ENI

Siemens

S7-200

CPU212, CPU214, CPU215, CPU216, CPU221, CPU222, CPU224, CPU226, CPU226XM

Not used (connect to CPU module)

S7-300

CPU313, CPU314, CPU315, CPU315-2DP, CPU316, CPU318

CP-340, CP-341

S7-400

CPU412, CPU414, CPU416, CPU416F-2, CPU417

CP-440, CP-441

Keyence

KV-700, KV-1000

KV-700, KV-1000

Not used (connect to CPU module)KV-L20R

KV KV-10, 16, 24, 40 Not used (connect to CPU module)

KZKZ-10, 16, 20, 24, 40, 80

Not used (connect to CPU module)

Sharp

New Satellite JW

JW-21CU, JW-22CU, JW-31CUH/H1, JW-32CUH/H1, JW-33CUH/H1/H2/H3

JW-21CM

JW-50CU/CUH, JW-70CU/CUH,JW-100CU/CUH

JW-10CM

JW-22CU, JW-70CU/CUH, JW-100CU/CUH, JW-32CUH/H1, JW-33CUH/H1/H2/H3

Not used (connect to CPU)

Hitachi

S10mini S10miniNot used (connect to CPU module)Used

S10V LQP510

Not used (connect to CPU module)LQE560LQE565

JTEKT(Toyoda Machine)

TOYOPUC-PC2J PC2J Not used (built-in computer link)

TOYOPUC-PC3JPC3J, PC3JD, PC3JG

Not used (built-in computer link)

Manu-facturer Series

Applicable System

(CPU Module)Link Unit

The host interface driver can be downloaded from IDEC’s web site: http://www.idec.com/japan/

Page 7: Operator Interfaces Selection Guide - flexitec.com.sgflexitec.com.sg/wp-content/uploads/2014/12/Touch-Screen-HG1F... · A1SJ71C24-R2, A1SJ71UC24-R2, A1SJ71C24-R4, A1SJ71UC24-R4 A2CCPUC24

HG1F/2F/3F/4F Operator Interfaces

1239

ControlUnits

Display Lights

DisplayUnits

SafetyProducts

TerminalBlocks

Comm.Terminals

AS-Interface

Relays & Timers

Sockets

Circuit Protectors

Power Supplies

PLCs & SmartRelay

Operator Interfaces

Sensors

Control Stations

Explosion Protection

References

FlushSilhouette

The host interface driver can be downloaded from IDEC’s web site: http://www.idec.com/japan/

Toshiba Machine Works

TC200 TC3-13B1 Not used (connect to CPU module)

TCminiTC03-01TC03-02

Not used (connect to CPU module)

GE Fanuc Automa-tion

Series 90-30

CPU331, CPU341, CPU350, CPU351, CPU352, CPU360, CPU363, CPU364, CPU374

IC693CMM311

CPU311, CPU313, CPU323, CPU331, CPU341, CPU350, CPU351, CPU352, CPU360, CPU363, CPU364, CPU374

Not used (connect to CPU power module)

VersaMaxNano, Micro (14, 23, 28 points)

Not used (connect to CPU module)

Schneider

TwidoTWDLCAA16DRF, TWDLCAA24DRF

TWDNAC232D, TWDNAC485D, TWDNAC485T

Modicon

Momentum 171CCC96020 Not used (processor ethernet port)

AROMAT

FP seriesFP0, FP1, FP10, FP10SH, FP2, FP2SH, FP

Not used (connect to CPU module)

Yaskawa

Machine Controller

MP920, MP930, MP2300

Not used (connect to CPU module)Communication module 217IF

Koyo

DirectLOGIC 05 DL05 D0-ECOMD0-ECOM100DirectLOGIC 06 DL06

DirectLOGIC 205

D2-240,D2-250,D2-250-1,D2-260

D2-ECOMD2-ECOM-FD2-ECOM100

KOSTAC SZ SZ-4Not used (connect to CPU module communication port)

KOSTAC SU

SU-5E, SU-6B

Not used (connect to CPU module communication port)

SU-6H U-01DM

SU-5E, SU-6B,SU-5M, SU-6M

U-01DMD4-ECOMD4-ECOM-FD4-ECOM100

FANUC

Power MatePower Mate-MODEL D

Not used (connect to CPU module)

Series16i160i

Not used

Yokogawa

FACTORY ACE

FA-M3 (F3SP05, F3SP20, F3SP21, F3SP25, F3SP30, F3SP35, F3SP38, F3SP53, F3SP58, F3FP36, F3BP20, F3BP30)

F3LC11-1NF3LC11-2N

FA-M3 (F3SP05, F3SP21, F3SP25, F3SP28, F3SP35, F3SP38, F3SP53, F3SP58)

Not used

Fuji Electric

FREX-PC

NB1, NB2, NB3, NJ-CPU-E4, NJ-CPU-A8, NJ-CPU-B16, NS

Not used (connect to CPU module)

NB-RS1-AC/DC, NJ-RS2, NJ-RS4, NS-RS1

MICREX-F

F55 NV1L-RS2

F70NC1L-RS2NC1L-RS4

F80H, F120H, F120S, F140S, F150S

FFU120B

F30, F50, F50H, F55, F60, F70, F70S, F80H, F81, F120H, F120S, F140S, F150S, F250

FFK120A-C10

Toshiba

PROSECT Series

T1-16, T1-28, T1-40Not used (connect to CPU module)CU111

T1-40SNot used (connect to CPU module)CU111

PU224 Not used (connect to CPU module)

PU234ENot used (connect to CPU module)CM231ECM232E

PU215N, PU235N, PU245N

Not used (connect to CPU module)

PU315, PU325,PU325H, PU326H

Not used (connect to CPU module)

V Series

PU672T, PU662T, PU612E, L1PU11H, L1PU12H,S2PU82, S2PU72, S2PU32, S2PU22,S3PU65, S3PU55, S3PU45, S3PU21

Not used (connect to CPU module)

Manu-facturer Series

Applicable System

(CPU Module)Link Unit

LSIndustrial Systems

MASTER-K

K10S1 Not used (connect to CPU module)K80S, K120S, K200S

Not used (connect to CPU module)

K80SG7L-CUEBG7L-CUEC

K200SG6L-CUEBG6L-CUEC

K300S G4L-CUEA

Manu-facturer Series

Applicable System

(CPU Module)Link Unit

Page 8: Operator Interfaces Selection Guide - flexitec.com.sgflexitec.com.sg/wp-content/uploads/2014/12/Touch-Screen-HG1F... · A1SJ71C24-R2, A1SJ71UC24-R2, A1SJ71C24-R4, A1SJ71UC24-R4 A2CCPUC24

HG1F/2F/3F/4F Operator Interfaces

1240

HG Available Functions

1: Available on models with the Ethernet

2: Available on models with the USB interface

3: Available on models with the CF card slot

4: Except for models with the USB interface

5: Replaced at IDEC

Category Item HG1FHG2F

HG3F HG4FHG2S

Touch Switch Type CC Switch Type Touch Switch Type CC Switch Type

Communication

PLC link communication x x x x x x x

DM link communication x x x x x x x

O/I link communication x x x x x x (slave only) x (slave only)

Ethernet — — — x x — —

No host x x x x x x x

User Memory 1 MB 2 MB 2 MB 6 MB 6 MB 2 MB 2 MB

Interface

RS232C/RS485 (422) x x x x x x x

Ethernet — — — x

1 x

1 — —

USB — x

2 x

2 — — — —

CF card slot — x

3 x

3 x

3 x

3 — —

Parallel — — — x x — —

Display Color256 colors — x x x x x x

Monochrome x x x — — x x

Resolution 300

×

100 320

×

240 320

×

240 640

×

480 800

×

600 320

×

240 320

×

240

Touch Switch Analog 16

×

12 16

×

8 32

×

24 40

×

30 16

×

12 10

×

12

CC Switch — — 4

×

1 row (bottom) — — — 6

×

2 columns

Expansion UnitDigital I/O unit x x x x x — —

L

ON

W

ORKS

communication unit x x x — — — —

Features

System program download x x x x x x x

Font download x x x x x x x

Download via Ethernet — — — x

1 x

1 — —

Download via O/I link x x x x x x x

Project transfer via CF card — x

3 x

3 x

3 x

3 — —

Printer output — x

4 x

4 x x x x

External input/output — — — — — x x

Backlight replacement x x x x x x

5 x

5

Environment resistance x x x x x x x

Functions

Simulation x x x x x x x

Pass through x x

4 x

4 x x x x

Device monitor x x x x x x x

Web server function — — — —

1 —

1 — —

Overlapped screens x x x x x x x

Sub-screen superimpose x x x x x x x

Text group switching x x x x x x x

Script x x x x x x x

Part operating condition setting x x x x x x x

Alarm log x x x x x x x

Logging x x x x x x x

Recipe x x x x x x x

Password setting x x x x x x x

Page 9: Operator Interfaces Selection Guide - flexitec.com.sgflexitec.com.sg/wp-content/uploads/2014/12/Touch-Screen-HG1F... · A1SJ71C24-R2, A1SJ71UC24-R2, A1SJ71C24-R4, A1SJ71UC24-R4 A2CCPUC24

1241

ControlUnits

Display Lights

DisplayUnits

SafetyProducts

TerminalBlocks

Comm.Terminals

AS-Interface

Relays & Timers

Sockets

Circuit Protectors

Power Supplies

PLCs & SmartRelay

Operator Interfaces

Sensors

Control Stations

Explosion Protection

References

FlushSilhouette

HG1F Operator Interface

Clear legible display of 300 ××××

100 pixelsMultiple functions comparable to larger operator interfaces

High-contrast monochrome LCD, super bright 500 cd/m

2

(luminance according to LCD manufacturer’s specifications)

16 adjustable brightness levels

All Windows® fonts can be displayed.

High-performance CPU ensures quick response in opera-tion and display.

Analog touch panel enables flexible screen layout.

User communication functions enable connection to bar-code readers and other peripherals.

High-speed O/I link function enables connection to a maxi-mum of 16 HG units to a host, using optional O/I link unit HG9Z-2G1.

Thin housing style — only 35.3mm deep behind the panel

WindO/I-NV2 software is used for easy screen design.

Compatible with IDEC HG2F, HG3F, HG4F, and HG2S dis-plays.

Multilingual capabilities, such as English, simplified and tra-ditional Chinese, Korean, and central European languages.

• UL, c-UL listed (except silver bezel), EN compliant

Types

Note: Each HG1F operator interface is supplied with four mounting clips SLD-K02 and one battery HG9Z-XR1.• Options

Note 1: For cable connection diagrams, see the host interface manual which is stored on the WindO/I-NV2 CD.Note 2: Computer link cable 4C (FC2A-KC4C) for IDEC’s MicroSmart and OpenNet Controller is also applicable.• Replacement Parts

Display Screen Operation Type Maintenance Interface Host Interface Housing/

Bezel Color Type No. Remarks

4.6-inch STN monochrome LCD Touch screen RS232C

RS232CLight gray HG1F-SB22BF-W UL, c-UL, CEDark gray HG1F-SB22BF-B UL, c-UL, CE

Silver HG1F-SB22BF-S CE

RS485/422Light gray HG1F-SB22YF-W UL, c-UL, CEDark gray HG1F-SB22YF-B UL, c-UL, CE

Silver HG1F-SB22YF-S CE

Name Type No. Ordering Type No. Description Length Connector to

the Host Mode

PLC Connection Cable

(Note 1)

HG9Z-XC183For IDEC’s MicroSmart, OpenNet Con-troller, port 2

3m Mini DIN 8-pin RS232C

FC4A-KC1C For IDEC’s MicroSmart, port 1 5m Mini DIN 8-pin RS232CHG9Z-XC115 For IDEC’s FA-3S SIF2 5m Dsub 9-pin female RS232CHG9Z-XC245 For Mitsubishi FX direct connection 5m Mini DIN 8-pin RS422HG9Z-XC255 For Mitsubishi A/QnA direct connection 5m Dsub 25-pin female RS422HG9Z-XC265 For Mitsubishi Q series direct connection 5m Mini DIN 6-pin RS232CHG9Z-XC145 For Mitsubishi computer link unit 5m Dsub 25-pin female RS232CHG9Z-XC155 For OMRON link unit 5m Dsub 25-pin female RS232CHG9Z-XC203 For Mitsubishi computer link unit 3m Dsub 9-pin female RS232C

HG9Z-XC213For OMRON CPU unit RS232C interface (except C20H, 28H, 40H)

3m Dsub 9-pin female RS232C

Maintenance Cable HG9Z-XCM22 D-sub 9-pin female connector to connect to computer (2m long) (Note 2)Protective Sheet HG9Z-1D HG9Z-1DPN05 For protecting the HG1F screen (5 pcs/pack)O/I Link Unit HG9Z-2G1 Communication unit for O/I linkConfiguration Software

HG9Y-ZSS2WWindO/I-NV2 on CD (English/Japanese/Chinese compatible) without a printed manualPDF files of English/Japanese/Chinese manuals are stored on the CD.

Manual HG9Y-B596 English hardware/software manual

Name Type No. Ordering Type No. DescriptionReplacement Backlight (CCFL) HG9Z-1FB One backlight is supplied with HG1F.Mounting Clip SLD-K02 SLD-K02PN10 10 pcs/pack (four pieces are supplied with HG1F)Replacement Battery HG9Z-XR1 Lithium battery CR2032 (one battery is supplied with HG1F)

Page 10: Operator Interfaces Selection Guide - flexitec.com.sgflexitec.com.sg/wp-content/uploads/2014/12/Touch-Screen-HG1F... · A1SJ71C24-R2, A1SJ71UC24-R2, A1SJ71C24-R4, A1SJ71UC24-R4 A2CCPUC24

HG1F Operator Interface

1242

General Specifications

Operation Specifications

Function Specifications

Display Specifications

Note: The backlight life refers to the time until the surface brightness reduces to a half after using continuously at room temperatures.

Interface Specifications

Rated Power Voltage 24V DC

Power Voltage Range 20.4 to 28.8V DC

Power Consumption 10W maximum

Power Inrush Current 20A maximum

Allowable Momentary Power Interruption

10 ms minimum

Dielectric Strength 1,000V AC, 10 mA, 1 minute between power and FG terminals

Insulation Resistance50 MΩ minimum between power and FG terminals (500V DC megger)

Backup BatteryCR2032 lithium primary batteryLife approx. 4 years (25°C)

Operating Temperature 0 to 50°C

Operating Humidity 10 to 90% RH (no condensation)

Storage Temperature –20 to +60°C

Storage Humidity 10 to 90% RH (no condensation)

Pollution Degree 2 (IEC 60664-1)

Corrosion Immunity Atmosphere free from corrosive gases

Vibration Resistance (damage limits)

10 to 20 Hz amplitude 0.625 mm, 20 to 55 Hz acceleration 9.8 m/s2, 2 hours per axis on each of three mutually perpendicular axes

Shock Resistance (damage limits)

147 m/s2, 11 ms, 5 shocks on each of three mutually perpen-dicular axes

Noise Immunity

Fast transient/burst test, Common mode: Level 3, Power terminals: ±2 kV, Communication line: ±1 kV (IEC 61000-4-4)

Electrostatic Discharge

ESD-3 (RH-1), Level 3, (contact ±6 kV, air ±8 kV) (IEC 61000-4-2)

Mounting Panel mounting

Degree of Protection IP65, NEMA Type 13 (operator)

Dimensions 147W × 76H × 39.3D mm

Weight (approx.) 280g

Switching Element Analog resistive membrane

Operating Force 0.2 to 0.8N

Mechanical Life 1,000,000 operations

Acknowledge Sound Electronic buzzer

Screen Types Base screen, popup screen, system screen

No. of Screens Base screen: 3000 max., popup screen: 3000 max.

User Memory 1 MB (including expansion fonts)

Parts

Bit Button, Word Button, Goto Screen Button, Print Button, Key Button, Multi Switch Keypad, Selector Switch, Potentiom-eter, Numerical Input, Character Input, Pilot Lamp, Multi-State Lamp, Picture Display, Message Display, Message Switching Display, Alarm List Display, Alarm Log Display, Numerical Dis-play, Bar Graph, Trend Chart, Pie Chart, Meter, Calendar, Bit Write Command, Word Write Command, Goto Screen Com-mand, Multi Command, Print Command, Screen Script Com-mand, Timer

CalendarYear, Month, Day, Hour, Min., Sec., Day of Week±30 sec per month (at 25°C)

Power Failure Backup Data

Calendar, log data, keep internal relay, keep internal register

Battery Life 4 years (at 25°C)

LCD Monochrome STN

Effective Display Area 111.4W × 38.4H mm

Display Resolution 300W × 100H pixels

LCD Life 50,000 hours minimum

Contrast Adjustment Possible in steps using the front touch screen

Backlight Cold-cathode tube

Backlight Life 50,000 hours nominal (Note)

Backlight Control Automatic OFF

Backlight Replacement Possible

Display Character Size

1/4 size

8 × 8 pixels (Western European language: ISO 8859-1, Central European language: ANSI 1250, Baltic: ANSI1257, Cyrillic: ANSI1251, Japanese katakana and symbols: JIS 8-bit code)

1/2 size

8 × 16 pixels (Western European language ISO 8859-1, Central European language: ANSI 1250, Baltic: ANSI1257, Cyrillic: ANSI1251, Japanese katakana and symbols: JIS 8-bit code)16 × 32 pixels, 24 × 48 pixels, 32 × 64 pixels (Western Euro-pean language: ISO 8859-1)

Full size16 × 16 pixels (Japanese JIS first and second level charac-ters, simplified Chinese, traditional Chinese, Korean)

Double size32 × 32 pixels (Japanese JIS first level characters, Mincho font)

Quantity of Characters

1/4 size 37 characters × 12 lines

1/2 size 37 characters × 6 lines

Full size 18 characters × 6 lines

Double size 9 characters × 3 lines

Character Magnification 0.5, 1, 2, 3, 4, and 8 vertically and horizontally

Character Attribute Blink (1 or 0.5 sec period), reverse, bold, shadowed

Graphics TypeStraight line, polyline, rectangle, circle, ellipse, arc, pie, equilateral polygons (3, 4, 5, 6, 8), paint, bitmap image

Window Display 3 popup screens + 1 system screen

RS

232C

Electrical Characteristics EIA RS232C compliant

Transmission Speed1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps

Synchronization Asynchronous

Communication Method Half or full duplex

Control System Hardware control or none

Connector D-sub 9-pin female connector

RS

485/

RS

422

Electrical Characteristics EIA RS485/RS422 compliant

Transmission Speed1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps

Synchronization Asynchronous

Communication Method Half or full duplex

Control System Hardware control or none

ConnectorRS485: D-sub 9-pin female connectorRS422: 5-pole terminal block

Mai

nten

ance

C

omm

unic

atio

n Electrical Characteristics EIA RS232C compliant

Transmission Speed 9600, 19200, 38400, 57600, 115200 bps

Synchronization Asynchronous

Communication Method Half duplex, proprietary protocol

Connector Mini DIN 8-pin connector

O/I

Link

C

omm

unic

atio

n Electrical Characteristics EIA RS485 compliant

Transmission Speed 19200, 38400, 57600, 115200 bps

Synchronization Asynchronous

Communication Method Half duplex, proprietary protocol

Connector Special connector

Dimensions

136.8

65.8

35.339.3

Panel Thickness 1.6 to 5

The above figure illustrates the RS485/422 version.

4

76.0

38.4

111.4

147

137+1.5 0

66+

1 0

Panel Cut-out

All dimensions in mm.