Operator Interface (small type) CC Pendant Teaching Pendant
HG1F HG2S (color) HG2S (monochrome) HG1H HG1T
4.6 inches 5.7 inches 5.7 inches 4 inches 4 inches
• Analog touch panel enables flexible screen layout.
• High-performance CPU ensures quick response in operation and display.
• Equipped with a 3-position enabling switch
• High-performance RISC CPU ensures stress-free quick response.
• CC switches and mechani-cal switches make up an ideal HMI equipment.
• CC switches and mechani-cal switches make up an ideal HMI equipment.
• IP65 water- and dust-proof structure
• Equipped with a 3-position enabling switch
• Mechanical switches such as key selector switches and pushbuttons can be installed.
• Equipped with a 3-position enabling switch
• Up to 4 mechanical switches such as pushbuttons can be installed.
• LCD with or without backlight available
• Compact size, lightweight 600g
Monochrome STN Color STN Monochrome STN Monochrome STN Monochrome STN
111.4 × 38.4 118.2 × 89.4 118.2 × 89.4 — 95.96 × 31.96
300 × 100 320 × 240 320 × 240 — 192 × 64
Monochrome 256 colors Monochrome Monochrome Monochrome
37 characters × 12 lines 40 characters × 15 lines 40 characters × 15 lines 20 characters × 4 lines 12 characters × 4 lines
— 16 × 12 10 × 12 (CC switch type)
16 × 1210 × 12 (CC switch type) — —
— 2 × 6 2 × 6 — —
Yes Yes Yes Yes Yes
Yes — — Yes Yes
Yes — — Yes Yes
— Yes Yes — —
Yes Yes Yes Yes Yes
— — — — —
— — — — —
— — — — —
— 4 points 4 points — —
— 3 points 3 points — —
— — — — —
24V DC 24V DC 24V DC 24V DC 24V DC
0 to 50°C 0 to 40°C 0 to 40°C 0 to 40°C 0 to 40°C
IP65 (operator) IP65 (except CC switch and connector)
IP65 (except CC switch and connector) IP54 (except cable connector) IP54 (except cable connector)
147 × 76 × 39.3 228 × 186 × 57 228 × 186 × 57 110 × 218.4 × 66.6 133 × 250 × 58.3
280g 1200g (except cable) 1200g (except cable) 400g (except cable) 600g (except cable)
Yes Yes Yes Yes Yes
WindO/I-NV2 WindO/I-NV2 WindO/I-NV2 WindO/I-NV2 WindE/T
1241 1249 1249 1255 1258
HG
Series
Software (Wind O/I-NV2)
1234
Design tool WindO/I-NV2 assists you in programming your HG family O/Is.
Windows is a registered trademark of Microsoft Corporation, USA in the USA and other countries.
•
OS Windows 95 (OSR2 or later)/98/Me
•
RAM 64 MB minimumNT4.0/2000/XP/Vista
•
Hard Disk Space 150 MB minimum
•
Computer PC-AT compatible
•
Graphic SVGA (800
×
600) or higher
•
CPU Pentium 200 MHz or higher
•
Others Mouse, CD-ROM drive
Screen List Project Settings ListScreens can be duplicated and prop-erty can be changed easily. Projects can also be edited effectively. Import and export functions make it possible to replace devices, text, and shapes all at once. Exported CSV files can be edited using Excel.
Screen Preview ListScreens can be selected from the preview images and opened quickly.
Object ListInformation and figures of devices, condition types, and oper-ation conditions arranged on the screen can be confirmed. Properties can also be changed using the list.
The part selected in the object list is also reflected in the editing screen.
Work AreaThe project structure can be listed for easy viewing, and switched to the editing screen by one click.
System Requirements
Software
HG
Series
Software (Wind O/I-NV2)
1235
ControlUnits
Display Lights
DisplayUnits
SafetyProducts
TerminalBlocks
Comm.Terminals
AS-Interface
Relays & Timers
Sockets
Circuit Protectors
Power Supplies
PLCs & SmartRelay
Operator Interfaces
Sensors
Control Stations
Explosion Protection
References
FlushSilhouette
A maximum of 5 base screens can be overlapped, and sub screens can also be popped up, so screens can be arranged very effectively. Subscreens can be resized and made transparent to show the background using the superim-pose function as required. In addition, subscreens can be designed to have a move or close button.
Screen data can be imported from another project. Figures and scripts stored in library can be reused, so accumulated software properties can be used effectively. Image data of BMP, JPG, DXF, WMF, and ICO files as well as CAD data can also be used.
Legends for switches and lamps, and text massages used for the alarm func-tion can be managed in the text browser. Text property settings (font, text, color, and size) can be exported to a CSV format file, which can then be edited on Excel and imported back to the text browser, resulting in effective screen editing.
The device browser is used to list devices used in the project and also to replace used devices at once.
Operating conditions for switches and lamps, bit/word write, and screen switching can be programmed in the property settings for each part. Lamps can be easily set to turn on, turn off, and flash.
The HG can process various operations to reduce the task of the host. On the script editor, conditional equations and functions can be selected and input-ted from the function list. Syntax error check function is also available.
The standard key pad can be used for easy input-ting of numerals and text. In the pop-up display mode, the keyboard can be moved to the best position automatically.
Alarm log data can be listed during operation. Details of each data item can also be confirmed easily.
Bar graph, trend chart, pie chart, and meter can be displayed, and their colors, scales, and labels can be set easily. On the bar graph, the display color can be changed or flashed when an input overflow occurs.
Flexible Screen Display for Efficient Editing Possible to Reuse Data
Base Screen
Sub Screen
Text Browser for Text Data Management Device Browser for Listing Used Devices
Easy Programming of Parts Operating Conditions Script Function for Assisting the Host
Numeric Key Pad Settings Alarm Functions Various Graph Functions
HG1F/2F/3F/4F Operator Interfaces
1236
The HG series is equipped with most demanded features and functions.
Alarm logging display, alarm list display, and data logging display functions make it easy to view the production information and perform data collection and management.Alarm and data logging data can be saved on a CF card in a CSV file format, which can be edited on a PC. In addition, the current screen on the HG can be printed out or saved in a BMP file format.
Using the web browser on a PC or PDA, machine operating sta-tuses can be monitored and CF card data can be collected to the PC through an Ethernet network. Data can be collected from remote areas.
Record Viewer
Using utility software Record Viewer, alarm and log data stored in the HG can be uploaded through the maintenance communication and displayed on the PC.
After downloading a created project to the HG, actual operation can be confirmed while editing the data. Simulation mode makes it pos-sible to debug the project while confirming the HG operation without the need for connection to the host.
Preset values of the machine (positioning, work piece dimensions, etc.) can be stored on the internal memory of the HG. Using the stored preset values (recipe data), the machine can be initialized easily. The recipe data can be stored on the CF card and edited on a PC.(Available on HG models with CF card slot.)
Powerful Functions for Production Data Logging and Management
Alarm Logging and Data Logging
Logging Data
Alarm Log Data
CF CardPC
Monitor and Data Logging through Ethernet View Logged Data on a PC
Ethernet
LAN
LAN
PC or PDA withweb browser
HG3F/4F
Host
Record Viewer Screen Upload and View Logging Data
Initialize Logging Data
PC
HG1F/2F/3F/4FHG2S
Speeding Production System Start-up
Debugging Function Recipe Function
HG1F/2F/3F/4FHG2S
Host
PC
Screen Monitor Window
HG2F/3F/4F
CF Card
PLC
Model CDevice Data
D200 10
D201 11
D202 40
D203 20
15
Device Data
D200 8
D201 12
D202 30
D203 16
10
Model B
Recipe Data
Device Data
D200 10
D201 14
D202 32
D203 18
Model A
...
Features
HG1F/2F/3F/4F Operator Interfaces
1237
ControlUnits
Display Lights
DisplayUnits
SafetyProducts
TerminalBlocks
Comm.Terminals
AS-Interface
Relays & Timers
Sockets
Circuit Protectors
Power Supplies
PLCs & SmartRelay
Operator Interfaces
Sensors
Control Stations
Explosion Protection
References
FlushSilhouette
.
The text group selection function enables to make a selection from a maximum of 16 languages by changing the assigned device value, even during operation.
Applicable Languages:
Western European languages (English, German, French, Italian, Spanish, Dutch, Norwegian, Danish, Finnish, Irish, etc.)Central European languages (Czech, Hungarian, Romanian, Croat-ian, Slovene, Polish, and Slavic)
Fonts used in Windows can be displayed on the HG screens, mak-ing it possible to design the attractive screen layout.
In the O/I link communication network, the screen display data can be downloaded to multiple slaves at once.
The HG models with the Ethernet capability can upload and down-loaded the screen display data through the Ethernet.
The screen display data can be downloaded and uploaded using the CF card without the need of a PC. The CF card can store multi-ple pieces of project data.
In the network where the HG is connected to an IDEC PLC using the computer link communication system and the PC is connected to the HG using the maintenance cable, the PC can exchange data with the PLC using WindLDR.
The screen display data can be downloaded and uploaded through the USB port on a computer.
Multilingual Capabilities for Global Applications
Easy Selection of Multiple Languages Compatible with Windows Fonts
Speeding Production System Start-up
Simultaneous Download through O/I Link Maintenance through Ethernet
HG1F/2F/3F/4F/2S
O/I Link
MasterPC
Slave Slave
Host
Ethernet
PC
HG3F/4F
Download from CF Card PLC Data Exchange through the HG Unit
CF CardHG2F/3F/4F
HG1F/2F/3F/4FHG2S
IDEC PLCMicroSmartMicro3COpenNet Controller
WindLDRPC
WindO/I-NV2
USB Port on HG2FDownload Service
Latest versions of WindO/I-NV2, host interface driver,and user’s manual can be downloaded from the IDECweb site. Since the system program for the HG canalso be downloaded from WindO/I-NV2, your HGseries devices can be updated to use the latest func-tionality.
http://www.idec.com/Products/ENG/Software/SoftwareDownloads.html
After installing WindO/I-NV2, the download page can beopened from the Windows start menu.
HG2FPC
USB
HG1F/2F/3F/4F Operator Interfaces
1238
Applicable PLCs
Manu-facturer Series
Applicable System
(CPU Module)Link Unit
IDEC
FA-3S
PF3S-CP12, PF3S-CP13
PF3S-SIF2, PF3S-SIF4, PF2-CLA
PF3S-CP11, PF3S-CP11T PF2-CLA
FA-2J PF2J-CPU1OpenNet Controller
FC3A-CP2Not used (connect to CPU module)FC4A-SX5ES1E
MicroSmart
FC4A-C10R2, FC4A-C10R2C
Not used (connect to CPU module)FC4A-SX5ES1E
FC4A-C16R2, FC4A-C16R2C,FC4A-C24R2, FC4A-C24R2C
Not used (connect to CPU module)FC4A-PC1, FC4A-PC3,FC4A-SX5ES1E
FC4A-D20K3, FC4A-D20S3,FC4A-D20RK1, FC4A-D20RS1,FC4A-D40K3, FC4A-D40S3
Not used (connect to CPU module)FC4A-HPC1, FC4A-HPC3,FC4A-HPH1 + FC4A-PC1,FC4A-HPH1 + FC4A-PC3,FC4A-SX5ES1E
MicroSmartPentra
FC5A-C10R2, FC5A-C10R2C,FC5A-C16R2, FC5A-C16R2C,FC5A-C24R2, FC5A-C24R2C
Not used (connect to CPU module)
FC4A-PC1, FC4A-PC3,FC5A-SIF2FC4A-SX5ES1E
FC5A-D16RK1, FC5A-D16RS1,FC5A-D32K3, FC5A-D32S3
Not used (connect to CPU module)FC4A-HPC1, FC4A-HPC3,FC4A-HPH1 + FC4A-PC1,FC4A-HPH1 + FC4A-PC3,FC5A-SIF2FC4A-SX5ES1J
Mitsubishi
MELSEC-A
A1N, A2N, A3NAJ71C24, AJ71C24-S3/-S6/-S8, AJ71UC24
A1SH-S1A1SJ71C24-R2, A1SJ71UC24-R2, A1SJ71C24-R4, A1SJ71UC24-R4
A2CCPUC24 Not used (connect to CPU module)A0J2, A0J2H A0J2-C214-S1A2A, A3A, A2U, A3U, A4U
AJ71C24-S6/-S8, AJ71UC24
A2N Not used (connect to CPU module)A1SJH, A1SH, A2SH, A2C, A0J2H
Not used (connect to CPU module)
A2A, A3A, A2US, A2USH
Not used (connect to CPU module)
A2U, A1SH-S1 Not used (connect to CPU module)
MELSEC-QnA
Q4ACPUQ4ARCPUQ3ACPUQ2ACPU-S1Q2ACPU
AJ71QC24N-R2AJ71QC24NAJ71QC24N-R4AJ71QE71N3-TAJ71QE71N-B2AJ71QE71N-B5
Q2ASHCPU-S1Q2ASHCPUQ2ASCPU-S1Q2ASCPU
A1SJ71QC24N-R2A1SJ71QC24NA1SJ71QE71N3-TA1SJ71QE71N-B2A1SJ71QE71N-B5
MELSEC-Q
Q00CPU, Q01CPU Not used (connect to CPU module)Q02CPU, Q02HCPU Q06HCPU,Q12PHCPU,Q25HCPU
QJ71C24, QJ71C24N, QJ71C24N-R2
Q00JCPU, Q00CPU, Q01CPU, Q02CPU, Q02HCPU, Q06HCPU, Q12HCPU, Q25HCPU
QJ71E71-100QJ71E71-B5QJ71E71-B2
Q02CPU, Q02CPU-A mode
Not used (connect to CPU module)
MELSEC-FX
FX0, FX0N, FX1, FX2, FX2C, FX0S, FX1S
Not used (connect to CPU module)
FX2N, FX2NC, FX1N, FX1NC
Not used (connect to CPU module)FX2NC-232ADP
FX2N FX2N-232-BD, FX2N-422-BD FX1N FX1N-232-BD, FX1N-422-BDFX3UC Not used (connect to CPU module)
OMRON
SYSMAC-C
C500, C500F, C1000H, C2000, C2000H
C120-LK201-V1, C120-LK202-V1, C500-LK201-V1, C500-LK203
C1000HF C500-LK203C200HS C200H-LK201, C200H-LK202
C200HE, C200HG, C200HX
C200H-LK201, C200H-LK202,C200HW-COM02/COM04/COM05/COM06, C200HW-COM03/COM06
C120, C120F C120-LK201-V1, C120-LK202-V1C20H, C28H, C40H, C60H
Not used (connect to CPU module)
CQM1H, C200HS-CPU21/23/31/33
Not used (connect to CPU module)
C200HE-CPU42, C200HG-CPU43/63, C200HX-CPU44/64
Not used (connect to CPU module)
CPM1, CPM1A, CPM2A
CPM1-CIF01, CPM1-CIF11
CPM2A Not used (connect to CPU module)
SYSMAC-CS1CS1G, CS1H Not used (connect to CPU module)CS1G, CS1H CS1W-SCB41 (Port 1) (Port 2)
SYSMAC-CJ1M CJ1M Not used (connect to CPU module)
Allen-Bradley
PLC-5
All PLC-5 models compatible with 1770-KF2
1770-KF2
All PLC-5 models Not used (connect to CPU module)SLC-500 (Half Duplex)
SLC5/03, SLC5/04
Not used (connect to CPU module)
Micro Logix (Full Duplex)
Micro Logix 1000,Micro Logix 1100,Micro Logix 1200,Micro Logix 1500
Not used (connect to CPU module)
ControlLogixControlLogix 5500ControlLogix 5555
Not used (connect to CPU module)1756-ENBT
CompactLogix1768 CompactLogix1769 CompactLogix
Not used (connect to CPU module)
FlexLogic1794-L331794-L34
Not used (connect to CPU module)
PLC-5PLC-5 1756-ENBTPLC-5E Not used (connect to CPU module)
SLC 500
SLC5/05SLC5/03SLC5/04SLC5/05
1761-NET-ENI
MicroLogix
MicroLogix 1000MicroLogix 1100MicroLogix 1200MicroLogix 1500
1761-NET-ENI
Siemens
S7-200
CPU212, CPU214, CPU215, CPU216, CPU221, CPU222, CPU224, CPU226, CPU226XM
Not used (connect to CPU module)
S7-300
CPU313, CPU314, CPU315, CPU315-2DP, CPU316, CPU318
CP-340, CP-341
S7-400
CPU412, CPU414, CPU416, CPU416F-2, CPU417
CP-440, CP-441
Keyence
KV-700, KV-1000
KV-700, KV-1000
Not used (connect to CPU module)KV-L20R
KV KV-10, 16, 24, 40 Not used (connect to CPU module)
KZKZ-10, 16, 20, 24, 40, 80
Not used (connect to CPU module)
Sharp
New Satellite JW
JW-21CU, JW-22CU, JW-31CUH/H1, JW-32CUH/H1, JW-33CUH/H1/H2/H3
JW-21CM
JW-50CU/CUH, JW-70CU/CUH,JW-100CU/CUH
JW-10CM
JW-22CU, JW-70CU/CUH, JW-100CU/CUH, JW-32CUH/H1, JW-33CUH/H1/H2/H3
Not used (connect to CPU)
Hitachi
S10mini S10miniNot used (connect to CPU module)Used
S10V LQP510
Not used (connect to CPU module)LQE560LQE565
JTEKT(Toyoda Machine)
TOYOPUC-PC2J PC2J Not used (built-in computer link)
TOYOPUC-PC3JPC3J, PC3JD, PC3JG
Not used (built-in computer link)
Manu-facturer Series
Applicable System
(CPU Module)Link Unit
The host interface driver can be downloaded from IDEC’s web site: http://www.idec.com/japan/
HG1F/2F/3F/4F Operator Interfaces
1239
ControlUnits
Display Lights
DisplayUnits
SafetyProducts
TerminalBlocks
Comm.Terminals
AS-Interface
Relays & Timers
Sockets
Circuit Protectors
Power Supplies
PLCs & SmartRelay
Operator Interfaces
Sensors
Control Stations
Explosion Protection
References
FlushSilhouette
The host interface driver can be downloaded from IDEC’s web site: http://www.idec.com/japan/
Toshiba Machine Works
TC200 TC3-13B1 Not used (connect to CPU module)
TCminiTC03-01TC03-02
Not used (connect to CPU module)
GE Fanuc Automa-tion
Series 90-30
CPU331, CPU341, CPU350, CPU351, CPU352, CPU360, CPU363, CPU364, CPU374
IC693CMM311
CPU311, CPU313, CPU323, CPU331, CPU341, CPU350, CPU351, CPU352, CPU360, CPU363, CPU364, CPU374
Not used (connect to CPU power module)
VersaMaxNano, Micro (14, 23, 28 points)
Not used (connect to CPU module)
Schneider
TwidoTWDLCAA16DRF, TWDLCAA24DRF
TWDNAC232D, TWDNAC485D, TWDNAC485T
Modicon
Momentum 171CCC96020 Not used (processor ethernet port)
AROMAT
FP seriesFP0, FP1, FP10, FP10SH, FP2, FP2SH, FP
∑
Not used (connect to CPU module)
Yaskawa
Machine Controller
MP920, MP930, MP2300
Not used (connect to CPU module)Communication module 217IF
Koyo
DirectLOGIC 05 DL05 D0-ECOMD0-ECOM100DirectLOGIC 06 DL06
DirectLOGIC 205
D2-240,D2-250,D2-250-1,D2-260
D2-ECOMD2-ECOM-FD2-ECOM100
KOSTAC SZ SZ-4Not used (connect to CPU module communication port)
KOSTAC SU
SU-5E, SU-6B
Not used (connect to CPU module communication port)
SU-6H U-01DM
SU-5E, SU-6B,SU-5M, SU-6M
U-01DMD4-ECOMD4-ECOM-FD4-ECOM100
FANUC
Power MatePower Mate-MODEL D
Not used (connect to CPU module)
Series16i160i
Not used
Yokogawa
FACTORY ACE
FA-M3 (F3SP05, F3SP20, F3SP21, F3SP25, F3SP30, F3SP35, F3SP38, F3SP53, F3SP58, F3FP36, F3BP20, F3BP30)
F3LC11-1NF3LC11-2N
FA-M3 (F3SP05, F3SP21, F3SP25, F3SP28, F3SP35, F3SP38, F3SP53, F3SP58)
Not used
Fuji Electric
FREX-PC
NB1, NB2, NB3, NJ-CPU-E4, NJ-CPU-A8, NJ-CPU-B16, NS
Not used (connect to CPU module)
NB-RS1-AC/DC, NJ-RS2, NJ-RS4, NS-RS1
MICREX-F
F55 NV1L-RS2
F70NC1L-RS2NC1L-RS4
F80H, F120H, F120S, F140S, F150S
FFU120B
F30, F50, F50H, F55, F60, F70, F70S, F80H, F81, F120H, F120S, F140S, F150S, F250
FFK120A-C10
Toshiba
PROSECT Series
T1-16, T1-28, T1-40Not used (connect to CPU module)CU111
T1-40SNot used (connect to CPU module)CU111
PU224 Not used (connect to CPU module)
PU234ENot used (connect to CPU module)CM231ECM232E
PU215N, PU235N, PU245N
Not used (connect to CPU module)
PU315, PU325,PU325H, PU326H
Not used (connect to CPU module)
V Series
PU672T, PU662T, PU612E, L1PU11H, L1PU12H,S2PU82, S2PU72, S2PU32, S2PU22,S3PU65, S3PU55, S3PU45, S3PU21
Not used (connect to CPU module)
Manu-facturer Series
Applicable System
(CPU Module)Link Unit
LSIndustrial Systems
MASTER-K
K10S1 Not used (connect to CPU module)K80S, K120S, K200S
Not used (connect to CPU module)
K80SG7L-CUEBG7L-CUEC
K200SG6L-CUEBG6L-CUEC
K300S G4L-CUEA
Manu-facturer Series
Applicable System
(CPU Module)Link Unit
HG1F/2F/3F/4F Operator Interfaces
1240
HG Available Functions
∗
1: Available on models with the Ethernet
∗
2: Available on models with the USB interface
∗
3: Available on models with the CF card slot
∗
4: Except for models with the USB interface
∗
5: Replaced at IDEC
Category Item HG1FHG2F
HG3F HG4FHG2S
Touch Switch Type CC Switch Type Touch Switch Type CC Switch Type
Communication
PLC link communication x x x x x x x
DM link communication x x x x x x x
O/I link communication x x x x x x (slave only) x (slave only)
Ethernet — — — x x — —
No host x x x x x x x
User Memory 1 MB 2 MB 2 MB 6 MB 6 MB 2 MB 2 MB
Interface
RS232C/RS485 (422) x x x x x x x
Ethernet — — — x
∗
1 x
∗
1 — —
USB — x
∗
2 x
∗
2 — — — —
CF card slot — x
∗
3 x
∗
3 x
∗
3 x
∗
3 — —
Parallel — — — x x — —
Display Color256 colors — x x x x x x
Monochrome x x x — — x x
Resolution 300
×
100 320
×
240 320
×
240 640
×
480 800
×
600 320
×
240 320
×
240
Touch Switch Analog 16
×
12 16
×
8 32
×
24 40
×
30 16
×
12 10
×
12
CC Switch — — 4
×
1 row (bottom) — — — 6
×
2 columns
Expansion UnitDigital I/O unit x x x x x — —
L
ON
W
ORKS
communication unit x x x — — — —
Features
System program download x x x x x x x
Font download x x x x x x x
Download via Ethernet — — — x
∗
1 x
∗
1 — —
Download via O/I link x x x x x x x
Project transfer via CF card — x
∗
3 x
∗
3 x
∗
3 x
∗
3 — —
Printer output — x
∗
4 x
∗
4 x x x x
External input/output — — — — — x x
Backlight replacement x x x x x x
∗
5 x
∗
5
Environment resistance x x x x x x x
Functions
Simulation x x x x x x x
Pass through x x
∗
4 x
∗
4 x x x x
Device monitor x x x x x x x
Web server function — — — —
∗
1 —
∗
1 — —
Overlapped screens x x x x x x x
Sub-screen superimpose x x x x x x x
Text group switching x x x x x x x
Script x x x x x x x
Part operating condition setting x x x x x x x
Alarm log x x x x x x x
Logging x x x x x x x
Recipe x x x x x x x
Password setting x x x x x x x
1241
ControlUnits
Display Lights
DisplayUnits
SafetyProducts
TerminalBlocks
Comm.Terminals
AS-Interface
Relays & Timers
Sockets
Circuit Protectors
Power Supplies
PLCs & SmartRelay
Operator Interfaces
Sensors
Control Stations
Explosion Protection
References
FlushSilhouette
HG1F Operator Interface
Clear legible display of 300 ××××
100 pixelsMultiple functions comparable to larger operator interfaces
•
High-contrast monochrome LCD, super bright 500 cd/m
2
(luminance according to LCD manufacturer’s specifications)
•
16 adjustable brightness levels
•
All Windows® fonts can be displayed.
•
High-performance CPU ensures quick response in opera-tion and display.
•
Analog touch panel enables flexible screen layout.
•
User communication functions enable connection to bar-code readers and other peripherals.
•
High-speed O/I link function enables connection to a maxi-mum of 16 HG units to a host, using optional O/I link unit HG9Z-2G1.
•
Thin housing style — only 35.3mm deep behind the panel
•
WindO/I-NV2 software is used for easy screen design.
•
Compatible with IDEC HG2F, HG3F, HG4F, and HG2S dis-plays.
•
Multilingual capabilities, such as English, simplified and tra-ditional Chinese, Korean, and central European languages.
• UL, c-UL listed (except silver bezel), EN compliant
Types
Note: Each HG1F operator interface is supplied with four mounting clips SLD-K02 and one battery HG9Z-XR1.• Options
Note 1: For cable connection diagrams, see the host interface manual which is stored on the WindO/I-NV2 CD.Note 2: Computer link cable 4C (FC2A-KC4C) for IDEC’s MicroSmart and OpenNet Controller is also applicable.• Replacement Parts
Display Screen Operation Type Maintenance Interface Host Interface Housing/
Bezel Color Type No. Remarks
4.6-inch STN monochrome LCD Touch screen RS232C
RS232CLight gray HG1F-SB22BF-W UL, c-UL, CEDark gray HG1F-SB22BF-B UL, c-UL, CE
Silver HG1F-SB22BF-S CE
RS485/422Light gray HG1F-SB22YF-W UL, c-UL, CEDark gray HG1F-SB22YF-B UL, c-UL, CE
Silver HG1F-SB22YF-S CE
Name Type No. Ordering Type No. Description Length Connector to
the Host Mode
PLC Connection Cable
(Note 1)
HG9Z-XC183For IDEC’s MicroSmart, OpenNet Con-troller, port 2
3m Mini DIN 8-pin RS232C
FC4A-KC1C For IDEC’s MicroSmart, port 1 5m Mini DIN 8-pin RS232CHG9Z-XC115 For IDEC’s FA-3S SIF2 5m Dsub 9-pin female RS232CHG9Z-XC245 For Mitsubishi FX direct connection 5m Mini DIN 8-pin RS422HG9Z-XC255 For Mitsubishi A/QnA direct connection 5m Dsub 25-pin female RS422HG9Z-XC265 For Mitsubishi Q series direct connection 5m Mini DIN 6-pin RS232CHG9Z-XC145 For Mitsubishi computer link unit 5m Dsub 25-pin female RS232CHG9Z-XC155 For OMRON link unit 5m Dsub 25-pin female RS232CHG9Z-XC203 For Mitsubishi computer link unit 3m Dsub 9-pin female RS232C
HG9Z-XC213For OMRON CPU unit RS232C interface (except C20H, 28H, 40H)
3m Dsub 9-pin female RS232C
Maintenance Cable HG9Z-XCM22 D-sub 9-pin female connector to connect to computer (2m long) (Note 2)Protective Sheet HG9Z-1D HG9Z-1DPN05 For protecting the HG1F screen (5 pcs/pack)O/I Link Unit HG9Z-2G1 Communication unit for O/I linkConfiguration Software
HG9Y-ZSS2WWindO/I-NV2 on CD (English/Japanese/Chinese compatible) without a printed manualPDF files of English/Japanese/Chinese manuals are stored on the CD.
Manual HG9Y-B596 English hardware/software manual
Name Type No. Ordering Type No. DescriptionReplacement Backlight (CCFL) HG9Z-1FB One backlight is supplied with HG1F.Mounting Clip SLD-K02 SLD-K02PN10 10 pcs/pack (four pieces are supplied with HG1F)Replacement Battery HG9Z-XR1 Lithium battery CR2032 (one battery is supplied with HG1F)
HG1F Operator Interface
1242
General Specifications
Operation Specifications
Function Specifications
Display Specifications
Note: The backlight life refers to the time until the surface brightness reduces to a half after using continuously at room temperatures.
Interface Specifications
Rated Power Voltage 24V DC
Power Voltage Range 20.4 to 28.8V DC
Power Consumption 10W maximum
Power Inrush Current 20A maximum
Allowable Momentary Power Interruption
10 ms minimum
Dielectric Strength 1,000V AC, 10 mA, 1 minute between power and FG terminals
Insulation Resistance50 MΩ minimum between power and FG terminals (500V DC megger)
Backup BatteryCR2032 lithium primary batteryLife approx. 4 years (25°C)
Operating Temperature 0 to 50°C
Operating Humidity 10 to 90% RH (no condensation)
Storage Temperature –20 to +60°C
Storage Humidity 10 to 90% RH (no condensation)
Pollution Degree 2 (IEC 60664-1)
Corrosion Immunity Atmosphere free from corrosive gases
Vibration Resistance (damage limits)
10 to 20 Hz amplitude 0.625 mm, 20 to 55 Hz acceleration 9.8 m/s2, 2 hours per axis on each of three mutually perpendicular axes
Shock Resistance (damage limits)
147 m/s2, 11 ms, 5 shocks on each of three mutually perpen-dicular axes
Noise Immunity
Fast transient/burst test, Common mode: Level 3, Power terminals: ±2 kV, Communication line: ±1 kV (IEC 61000-4-4)
Electrostatic Discharge
ESD-3 (RH-1), Level 3, (contact ±6 kV, air ±8 kV) (IEC 61000-4-2)
Mounting Panel mounting
Degree of Protection IP65, NEMA Type 13 (operator)
Dimensions 147W × 76H × 39.3D mm
Weight (approx.) 280g
Switching Element Analog resistive membrane
Operating Force 0.2 to 0.8N
Mechanical Life 1,000,000 operations
Acknowledge Sound Electronic buzzer
Screen Types Base screen, popup screen, system screen
No. of Screens Base screen: 3000 max., popup screen: 3000 max.
User Memory 1 MB (including expansion fonts)
Parts
Bit Button, Word Button, Goto Screen Button, Print Button, Key Button, Multi Switch Keypad, Selector Switch, Potentiom-eter, Numerical Input, Character Input, Pilot Lamp, Multi-State Lamp, Picture Display, Message Display, Message Switching Display, Alarm List Display, Alarm Log Display, Numerical Dis-play, Bar Graph, Trend Chart, Pie Chart, Meter, Calendar, Bit Write Command, Word Write Command, Goto Screen Com-mand, Multi Command, Print Command, Screen Script Com-mand, Timer
CalendarYear, Month, Day, Hour, Min., Sec., Day of Week±30 sec per month (at 25°C)
Power Failure Backup Data
Calendar, log data, keep internal relay, keep internal register
Battery Life 4 years (at 25°C)
LCD Monochrome STN
Effective Display Area 111.4W × 38.4H mm
Display Resolution 300W × 100H pixels
LCD Life 50,000 hours minimum
Contrast Adjustment Possible in steps using the front touch screen
Backlight Cold-cathode tube
Backlight Life 50,000 hours nominal (Note)
Backlight Control Automatic OFF
Backlight Replacement Possible
Display Character Size
1/4 size
8 × 8 pixels (Western European language: ISO 8859-1, Central European language: ANSI 1250, Baltic: ANSI1257, Cyrillic: ANSI1251, Japanese katakana and symbols: JIS 8-bit code)
1/2 size
8 × 16 pixels (Western European language ISO 8859-1, Central European language: ANSI 1250, Baltic: ANSI1257, Cyrillic: ANSI1251, Japanese katakana and symbols: JIS 8-bit code)16 × 32 pixels, 24 × 48 pixels, 32 × 64 pixels (Western Euro-pean language: ISO 8859-1)
Full size16 × 16 pixels (Japanese JIS first and second level charac-ters, simplified Chinese, traditional Chinese, Korean)
Double size32 × 32 pixels (Japanese JIS first level characters, Mincho font)
Quantity of Characters
1/4 size 37 characters × 12 lines
1/2 size 37 characters × 6 lines
Full size 18 characters × 6 lines
Double size 9 characters × 3 lines
Character Magnification 0.5, 1, 2, 3, 4, and 8 vertically and horizontally
Character Attribute Blink (1 or 0.5 sec period), reverse, bold, shadowed
Graphics TypeStraight line, polyline, rectangle, circle, ellipse, arc, pie, equilateral polygons (3, 4, 5, 6, 8), paint, bitmap image
Window Display 3 popup screens + 1 system screen
RS
232C
Electrical Characteristics EIA RS232C compliant
Transmission Speed1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps
Synchronization Asynchronous
Communication Method Half or full duplex
Control System Hardware control or none
Connector D-sub 9-pin female connector
RS
485/
RS
422
Electrical Characteristics EIA RS485/RS422 compliant
Transmission Speed1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps
Synchronization Asynchronous
Communication Method Half or full duplex
Control System Hardware control or none
ConnectorRS485: D-sub 9-pin female connectorRS422: 5-pole terminal block
Mai
nten
ance
C
omm
unic
atio
n Electrical Characteristics EIA RS232C compliant
Transmission Speed 9600, 19200, 38400, 57600, 115200 bps
Synchronization Asynchronous
Communication Method Half duplex, proprietary protocol
Connector Mini DIN 8-pin connector
O/I
Link
C
omm
unic
atio
n Electrical Characteristics EIA RS485 compliant
Transmission Speed 19200, 38400, 57600, 115200 bps
Synchronization Asynchronous
Communication Method Half duplex, proprietary protocol
Connector Special connector
Dimensions
136.8
65.8
35.339.3
Panel Thickness 1.6 to 5
The above figure illustrates the RS485/422 version.
4
76.0
38.4
111.4
147
137+1.5 0
66+
1 0
Panel Cut-out