Long Span Length > 1,8 km Span OPPC – up to 400 kV

OPGW / OPPC and Accessories

System Solution

OPGW / OPPC solution

Used fibres adding flexibility and future to fibre network

SMF-28e+ - extending G652 standard

– Improved bending – Advanced technology for future

networks

G657 Fibre optimised for Access-network and broadband installation in house

– Specified microbending down to 5mm bend radius

Fibres used in cables designs

G655 NZDS-Fibre optimised for Long Haul Terrestrial network

– Industry leading specification – Lowest PMD available

have to be resistant against stress of…

Installation

Ice loads

Temperature change

Lightning impact

Short circuit currents

Wind loads

therefore our OPGW / OPPC designs provide…

OPGW and OPPC

high fibre excess length of approx. 5‰, to compensate high strain stresses in case of strong ice- or wind loads

all materials being highly corrosion resistant

high mechanical flexibility avoiding long term fatigue and breaks of the wires and the optical fibre unit in case of high vibration stress

Design Features

Faultless operating of the fibers requires a proper protection against mechanical and thermal stress.

nkt manufacturers tubes from seamless welded stainless steel which protect the fibers

against various mechanical impacts, moisture and heat.

They are placed as a loose buffer in the center or in the first layers of the cable.

The fibers are embedded with a defined over length and space for movement in a special heat resistant and moisture repellent gel, to withstand bending, vibration, elongation and temperature variation.

Steel tube design description

All material are specially choosen to exclude corrosion

Example:

OPPC without Grease!!!

4 layer design

Salt Spray Corrosion Test: according to UNE-EN ISO 9227 NSS (07) or ASTM B-117(09), during 1000 hours.

Result no significant corrosion !

Excelent protection against corrosion

Excellent fibre protection in case of short circuit

Example short circuit test 3 layer design:

Test according to IEC 60794-4-1 Temperature far below max of the conductor No attenuation change

Fibre protection

Continuous operation during / after lightning test

Test performed according IEC 60794-1-2

Fibre: No attenuation change < +/- 0,05 dB/km

High remaining RTS in case of broken wires

Fibre protection

Engineering Works OPGW/OPPC system design, design sag-calculation

TestingType-, routine- and sample testing Factory acceptance tests Special optical and mechanical tests

SupervisionStringing and installation of Joint boxes and OPPC accessories

Measurement Services Optical measurements at site

Installation including splicing of (subcontracted) OPGW Joint Boxes OPPC Termination Units and OPPC straight Joints

Installation Training

What Services do we provide?

for more details you are welcome with …