Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. OPTIMIZATION OF STORAGE BIN GEOMETRY FOR HIGH TEMPERATURE PARTICLE-BASED CSP SYSTEMS Jeremy Sment, Kevin Albrecht, Joshua Christian, Clifford K. Ho Gen 3 Particle Pilot Plant (G3P3) 1

OPTIMIZATION OF STORAGE BIN GEOMETRY FOR HIGH … · 2019. 8. 14. · Partial fill vs Solid filled storage may be a significant consideration as solid fill loses slightly more heat

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: OPTIMIZATION OF STORAGE BIN GEOMETRY FOR HIGH … · 2019. 8. 14. · Partial fill vs Solid filled storage may be a significant consideration as solid fill loses slightly more heat

Sandia National Laboratories is a multimissionlaboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of

Energy’s National Nuclear Security Administration under contract DE-NA0003525.

OPTIMIZATION OF STORAGE BINGEOMETRY FOR HIGH TEMPERATURE PARTICLE-BASED CSP SYSTEMS

Je r e m y S m e n t , K e v i n A l b r e c h t , Jo s h u a C h r i s t i a n , C l i f f o r d K . H o

G e n 3 P a r t i c l e P i l o t P l a n t ( G 3 P 3 )

1

Page 2: OPTIMIZATION OF STORAGE BIN GEOMETRY FOR HIGH … · 2019. 8. 14. · Partial fill vs Solid filled storage may be a significant consideration as solid fill loses slightly more heat

Overview

•Introduction to G3P3 and Hot Particle Storage Design Considerations

•G3P3 Hot Particle Storage Vessel Design

•Design Analysis• Static • Cyclic Steady-State

•Conclusions and Next Steps

2

Page 3: OPTIMIZATION OF STORAGE BIN GEOMETRY FOR HIGH … · 2019. 8. 14. · Partial fill vs Solid filled storage may be a significant consideration as solid fill loses slightly more heat

G3P3 and Hot Particle Storage3

G3P3 1MWt pilot will be a vertically integrated falling particle receiver with 6MWh of thermal storage.◦ ~100,000 kg of flowing particles◦ Up to 60 m3 of storage volume

Target particle inlet temperatures to hot storage bin will be ≤ 800º C and must be between 765-775º C upon outlet. Cold storage will have inlet temperatures ~600º C.

Storage tanks will be internally insulated to minimize thermal stresses on metal shell and tower connections.

Page 4: OPTIMIZATION OF STORAGE BIN GEOMETRY FOR HIGH … · 2019. 8. 14. · Partial fill vs Solid filled storage may be a significant consideration as solid fill loses slightly more heat

Project Objective

Determine the basic geometry of the G3P3 particle storage bin. Use the metrics of heat loss and container stress to evaluate designs.• Top Angle: compare solid fill vs. partially filled concepts.• Bottom Hopper Angle: Mass Flow vs. Self Cleaning

Funnel Flow vs. Flat-bottom (stagnant)• How much does form factor affect heat loss and container

stress?

Page 5: OPTIMIZATION OF STORAGE BIN GEOMETRY FOR HIGH … · 2019. 8. 14. · Partial fill vs Solid filled storage may be a significant consideration as solid fill loses slightly more heat

10 Hour Heat Loss in Initially Cold Tank5

Time Dependent analysis was run to 10 hours◦ Initially 20ºC bin filled with 800ºC particles◦ Held for 10 hours where heat is transferred to refractory layers

Solid Filled (angled top) and Partially filled (flat top and flat bottom) designs were tested with buoyancy effects

Form factor varied with height to diameter ratios of 0.5, 1, and 2

Page 6: OPTIMIZATION OF STORAGE BIN GEOMETRY FOR HIGH … · 2019. 8. 14. · Partial fill vs Solid filled storage may be a significant consideration as solid fill loses slightly more heat

Optimization of Stress vs. Heat Loss: Results6

Stress decreases with elongation due to the Janssen effect but heat loss also increases with elongation as surface area increases.◦ Both factors are near minimum with minimum surface area geometry ◦ Reduction of floor area is a dominant factor over Janssen effect in size regime of 1MWt bin. ◦ Partial fill vs Solid filled storage may be a significant consideration as solid fill loses slightly more heat to

refractory ceiling material than air in the top of the tank. ◦ Surface area increase is nearly linear in 1MW size regime. Model of heat loss follows surface area curve.◦ Heat loss may be less in flat bottom bins due to the insulative effects of the stagnant floor particles. Higher

stress due in part to additional mass from stagnant particles on floor.

Page 7: OPTIMIZATION OF STORAGE BIN GEOMETRY FOR HIGH … · 2019. 8. 14. · Partial fill vs Solid filled storage may be a significant consideration as solid fill loses slightly more heat

Cyclic Analysis Cyclic analysis was run to quasi-steady-state conditions (model by Kevin Albrecht)◦ Initially cold bin filled instantly with 800ºC particles◦ Held for 10 hours where heat is transferred to refractory layers◦ Discharged instantly and held empty for 14 hours◦ Repeated daily until heat loss reaches quasi-steady-state◦ Form factor varied with height to diameter ratios of 1, 2, and 4 (6.58m, 8.47m, 9.79m

heights respectively)

7

Quasi steady-state ΔTRise time

Average Temp of Bulk SolidsInner Wall Temp

Insul Layer 1-2

Insul Layer 3-4Steel Shell (27º C)

Heat out Shell

Flux out Shell

Page 8: OPTIMIZATION OF STORAGE BIN GEOMETRY FOR HIGH … · 2019. 8. 14. · Partial fill vs Solid filled storage may be a significant consideration as solid fill loses slightly more heat

Cyclic Analysis Cyclic analysis was run to quasi-steady-state conditions (model by Kevin Albrecht)◦ Initially cold bin filled instantly with 800ºC particles◦ Held for 10 hours where heat is transferred to refractory layers◦ Discharged instantly and held empty for 14 hours◦ Repeated daily until heat loss reaches quasi-steady-state◦ Form factor varied with height to diameter ratios of 1, 2, and 4◦ Modeled initial G3P3 design: Min SA, Flat bottom, without bottom insulation

8

Page 9: OPTIMIZATION OF STORAGE BIN GEOMETRY FOR HIGH … · 2019. 8. 14. · Partial fill vs Solid filled storage may be a significant consideration as solid fill loses slightly more heat

Cyclic Analysis

787.2785.4

788.5

740.00

750.00

760.00

770.00

780.00

790.00

800.00

810.00

0 2 4 6 8 10 12 14 16

Aver

age

Tem

p of

Bul

k So

lids

(C)

DaysH/D=1 (45 deg Bottom, Partial Fill) H/D=2 (45 deg, Partial Fill)

H/D=4 (45 deg Bottom, Partial Fill) Min SA (Flat Bottom Partial Fill)

9

6.4%7.3%

5.8%

0.0%

5.0%

10.0%

15.0%

20.0%

25.0%

0 5 10 15

Aver

age

Tem

p of

Bul

k So

lids

(C)

Days% Daily Heat Loss H/D=1% Heat Loss H/D=2% Heat Loss H/D=4

◦ The temperature differences shown for the first 10 hours were significantly less (~1%) from shortest to tallest ratio after coming to quasi steady state

◦ Cycle time to steady state was similar for all geometries (~10 days).◦ Dynamic filling and discharging is expected to increase heat loss, models are being

developed.

787.9

6.1%

Page 10: OPTIMIZATION OF STORAGE BIN GEOMETRY FOR HIGH … · 2019. 8. 14. · Partial fill vs Solid filled storage may be a significant consideration as solid fill loses slightly more heat

Conclusions

Heat loss and container stress were used as metrics to inform decisions on hot particle storage geometry.• Heat losses are significant and proportional to surface area (SA) in the first 10 hours as the refractory absorbs heat

from the particles, however, cyclic models show that these losses diminish significantly after about 10 days of cycles and the thermal losses in elongated tanks may be practically comparable to those with minimal SA.

• As bins elongate, stresses decrease due to the reduction of the repose heap and the Janssen effect, but in the size regime of minimal SA, floor stress is dominated by the reduction of floor area more than the Janssen effect.

• Since there is minimal benefit to elongation as a means of reducing floor stress in the min SA size regime, the G3P3 storage design uses a geometry that minimizes the flowing surface area.

• Stress and heat loss measurements were significant factors in the choice of floor and roof angle. The G3P3 storage min minimizes surface area and stress and utilizes stagnant particles on the flat bottom to gain addition insulative performance.

Next Steps• Thermal Analysis During Dynamic Flow• Analysis at Commercial Scale

10

Page 11: OPTIMIZATION OF STORAGE BIN GEOMETRY FOR HIGH … · 2019. 8. 14. · Partial fill vs Solid filled storage may be a significant consideration as solid fill loses slightly more heat

Acknowledgments

This work is funded in part or whole by the U.S. Department of Energy Solar Energy Technologies Office under Award Number 33869◦ DOE Project Managers: Matthew Bauer, Andru Prescod

11

Page 12: OPTIMIZATION OF STORAGE BIN GEOMETRY FOR HIGH … · 2019. 8. 14. · Partial fill vs Solid filled storage may be a significant consideration as solid fill loses slightly more heat

Questions